HomeMy WebLinkAboutEngineering ENGINEERING 85828 1 44250-4860879630 1 Page 1/1 Ez*,( '1--?ESc-:3 o Date: February 23rd, 2021 — r ASCE 7 Components & Cladding Wall Pressure Calculator Prepared For: >' 7030 SW 16TH COURT PEMBROKE PINES FL Project: KOENIG CONDO DOOR REPLACEMENTZ. z Y o-YY Project Address: r 10044 S. OCEAN DRIVE UNIT 605 JENSEN BEACH Florida Box for Enginee�;5eal;.Orily=on :_a!\d for Permit&Use Frank Bennardo,PE FL46544 or k1chard•Neet,PE Fl-86488 The following has been considered in determining allowable stress design (ASD)wall opening pressures for the above- referenced location. ASCE:ASCE 7-16(7TH EDN FLORIDA BUILDING CODE, 2020 FBC, T°ry;D uFAH floor �I 2018 IBC) HFKM MRN) Wind Velocity: 170 MPH Exposure Category: D =❑ s HEIGHT Kd: 0.85 s s ® s s s Kzt: 1 yay Minimum Building Dimension: 170FT �'�� �+��", �a>� ELEVATION �'a I M DIY fASTHONsiONGIL a 4a Mean Roof Height: 106FT •�d, I L%;ME 5 oN IL 7/ Unit Elevation: 53FT &-- 6?'iED3F()R t J sROOF SLOPE: FLAT(<10°) A \s ® Number Of Openings: 1 ®®� COMPLIANCE ����'� � FLOWS HEIGHT Shutter: NO W'NO L Mark: 1 ST. L CIE CO 7'Y PLAN VIEW \4 I TALL N m° ■ ■ Height Of Opening: 80 IN , r COMPLEX Width Of Opening: 36 IN BCCC 9[ �I CORNERS sus %- BUILDINGS>li0'ROOF HEIGHT Zone. 4 W.SD%OF LEAST HORZONTAL DIMENSION OR40%OF MEAN ROOF HEIGHT IMRHI,WHICHEVER IS LESS RUT NOT C 4N OF LEAST HORIZONTAL DIMENSION OR SFr."USE CORNER ZONES IF ATALL IN QUESTION. SHUTTER OPTION FORCES OUTPUTTO HEIGHT•HEIGHT/S. Based on the above,the following ASD design pressures apply for the opening marks which shall correspond with contractor-supplied building layout: a: 17 FT Mark: 1 Wall Positve Pressure: 53.5PSF Wall Negative Pressure:-59PSF Design pressure results are in accordance with the Building &ASCE 7 codes listed above for an ENCLOSED structure only (Gcpi=+-0.18). Results are based on contractor-supplied data and are not field verified by this office. Input shall be verified by others prior to permit&use.Selection of all components&their respective approvals shall be by others and are to be within the ASD design pressure limitations stated herein. Results only valid with original or verifiable digital seal by a licensed PE of this firm. For more information on any of the terms listed herein, or to use a design tool to evaluate your openings,visit EngineeringExpress.com/Wind. Corp.Office:160 SW 12th Avenue Suite 106,Deerfield Beach,Florida 33442 (954)354-0660 1(866)396-9999 Team@EngineeringExpress.com I Engineering Express.com