Date: February 23rd, 2021 — r
ASCE 7 Components & Cladding Wall Pressure Calculator
Prepared For: >'
7030 SW 16TH COURT
PEMBROKE PINES FL
Project: KOENIG CONDO DOOR REPLACEMENTZ.
z
Y o-YY
Project Address: r
10044 S. OCEAN DRIVE UNIT 605
JENSEN BEACH Florida Box for Enginee�;5eal;.Orily=on :_a!\d for Permit&Use
Frank Bennardo,PE FL46544 or k1chard•Neet,PE Fl-86488
The following has been considered in determining allowable stress design (ASD)wall opening pressures for the above-
referenced location.
ASCE:ASCE 7-16(7TH EDN FLORIDA BUILDING CODE, 2020 FBC, T°ry;D
uFAH floor �I
2018 IBC) HFKM MRN)
Wind Velocity: 170 MPH
Exposure Category: D =❑ s HEIGHT
Kd: 0.85 s s ® s s s
Kzt: 1 yay
Minimum Building Dimension: 170FT �'�� �+��", �a>� ELEVATION �'a
I M DIY fASTHONsiONGIL
a 4a
Mean Roof Height: 106FT •�d, I L%;ME 5 oN IL 7/
Unit Elevation: 53FT &-- 6?'iED3F()R
t J sROOF SLOPE: FLAT(<10°) A \s ®
Number Of Openings: 1 ®®� COMPLIANCE
����'� � FLOWS HEIGHT
Shutter: NO W'NO L Mark: 1 ST. L CIE CO 7'Y PLAN VIEW \4 I TALL N m° ■ ■
Height Of Opening: 80 IN , r COMPLEX
Width Of Opening: 36 IN BCCC 9[ �I CORNERS sus %-
BUILDINGS>li0'ROOF HEIGHT
Zone. 4 W.SD%OF LEAST HORZONTAL DIMENSION OR40%OF MEAN ROOF HEIGHT IMRHI,WHICHEVER IS LESS
RUT NOT C 4N OF LEAST HORIZONTAL DIMENSION OR SFr."USE CORNER ZONES IF ATALL IN QUESTION.
SHUTTER OPTION FORCES OUTPUTTO HEIGHT•HEIGHT/S.
Based on the above,the following ASD design pressures apply for the
opening marks which shall correspond with contractor-supplied building
layout:
a: 17 FT
Mark: 1
Wall Positve Pressure: 53.5PSF
Wall Negative Pressure:-59PSF
Design pressure results are in accordance with the Building &ASCE 7 codes listed above for an ENCLOSED structure only
(Gcpi=+-0.18). Results are based on contractor-supplied data and are not field verified by this office. Input shall be verified
by others prior to permit&use.Selection of all components&their respective approvals shall be by others and are to be
within the ASD design pressure limitations stated herein. Results only valid with original or verifiable digital seal by a
licensed PE of this firm. For more information on any of the terms listed herein, or to use a design tool to evaluate your
openings,visit EngineeringExpress.com/Wind.