HomeMy WebLinkAboutRevisions OFFICE USE ONLY: L�
DATE FILED: !� 'a� PERMIT
REVISION FEE: File Copy RECEIPT#
PLANNING & DEVELOPMENT SERVICES
BUILDING&CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE,FL 34982-5652
(772)462.1553
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
LOCATION/SITE
ADDRESS:
5103 �3i�c1-� 1�.r�ve ��ori- Pierce FL 3y982
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: ST. LUCIE CO CERT. #:
BUSINESS NAME:
QUALIFIERS NAME:
ADDRESS:
CITY: STATE: ZIP:
PHONE(DAYTIME): FAX:
OWNER/BUILDER INFORMATION:
NAME:
ADDRESS:
CITY: STATE: f-L ZIP: 3y9$z
PHONE(DAYTIME: Z-ss 9-(.-4 o 4 FAX:
ARCHITECT/ENGINEER INFORMATION:
NAME:
ADDRESS:
CITY: :;, �� a ZIP:
PHONE(DAYTIME): `<-t
tl
SLCCC: 9123109
Revised 06130/17 �+ '� e
RECEIVED
MAR 0 4 2021 File Copy NEM0 I etc.
Permitting d2,7artn,enz Certificate of Authorization#32455
St. Lucie county a. ^'�� n ' ,1r�3 Christian Street, Unit#13
VIEWED FOR� Oxford(203) 262-9245
ENGINEER EVALUATE CODE COMBLIANCE CONSULT
RESISTO a division of Sop►emo,In Bey ]�aluation Report 7215.06.14-1110
RESISTO.
1640 rue Haggerty FL17084-R10
Drummondville,QC J2C 5P8 Canada Date of Issuance:06/20/2014
(819)478-2400 Revision 10:12/16/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 7th Edition(2020)Florida Building Code sections noted herein.
DESCRIPTION: RESISTO Modified Bitumen Roof Systems
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify MEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO I etc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 4,plus a 6-page Appendix.
Prepared by:
„1m•un, ,
v.
Robert J.M.Nieminen PE z . . -; ; The facsimile seal appearing was authorized by Robert Nieminen,P.E.
Florida Registration No.59166,Florida DC4ANE1983 on
,�:�...... �+�' do ument2020.This does not serve as an electronically signed
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
©2019 NEMO ETC,LLC
NNEMO etc.
ROOFING SYSTEMS EVALUATION:
Product Category: Roofing
Sub-Category: Modified Bitumen Roof Systems
Compliance Statement: RESISTO Modified Bitumen Roof Systems,as produced by RESISTO,a division of Soprema,
Inc., have demonstrated compliance with the following sections of the 7`h Edition (2020) Florida Building Code
through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements
and Limitations/Conditions of Use set forth herein.
2. . RP
Section Property Standard Year
1504.3.1 Wind resistance FM 4474 2011
1504.6 Physical properties ASTM G155 2013
1504.7 Impact resistance FM 4470 2016
1507.6.3 Material standard ASTM D1970 2015
1507.10.2 Material standard ASTM D4601 2012
1507.11.2 Material standard ASTM D6163 2015
1507.11.2 Material standard ASTM D6222 2011
Enti Examination Reference Date
ERD(TST6049) ASTM D6163 S35860.05.12-1-R2 03/14/2013
ERD(TST6049) ASTM D1970 S44870.04.14-1 and-4 04/10/2014
ERD(TST6049) FM 4474 S47190.06.14-2 06/20/2014
ERD(TST6049) ASTM D1970 SOPC-SC8970.15 07/22/2015
ERD(TST6049) FM 4474 SOPC-SC9315.07.15 07/22/2015
ERD(TST6049) ASTM D1970 SOPC-SC8970.08.15 08/31/2015
ERD(TST6049) ASTM D6163 S43400.08.14-5-R1 05/03/2017
FM Approvals(TST1867) FM 4470 3B1AO.AM 01/08/1998
FM Approvals(TST1867) FM 4470 797-08591-267 08/14/2013
NEMO(TST6049) ASTM D6163 4S-SOPC-18-003.11.18 01/14/2019
NEMO(TST6049) Criticality 4i-SOPC-I9-SSCRT-02.A 10/16/2019
NEMO(TST6049) FM 4474 4a-S0PC-I9-LSWUS-01.A 03/10/2020
NEMO(TST6049) ASTM D4601 4q-SOPC-20-SSMBB-01.A 03/25/2020
NEMO(TST6049) FM 4474 4a-SOPC-20-LSWUS-01.A 09/15/2020
PRI(TST5878) FM 4474 SOP-089-02-01 07/22/2016
PRI-CMT(TST5878) ASTM D6222 PRS-026-02-01 10/28/2016
PRI(TST5878) FM 4474 SOP-104-02-01 10/31/2016
PRI(TST5878) ASTM D4601 SOP-105-02-01 11/28/2016
PRI(TST5878) Criticality(TAS 117) SOP-080-02-02 12/16/2016
PRI(TST5878) FM 4474 SOP-119-02-01 04/14/2017
PRI(TST5878) FM 4474 SOP-128-02-01 08/18/2017
UL LLC (QUA9625) Quality Control Service Confirmation 05/30/2018
UL LLC (QUA9625) Quality Control Florida BCIS Current
MEMO ETC,LLC Evaluation Report 7215.06.14-R30
Certificate ojAuthorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL17084-R10
RESISTO,a division of Soprema,Inc. Revision 10:12/16/2020
Page 2 of 4
ONEMOletc.
4.1 This Evaluation Report covers RESISTO Modified Bitumen Roof Systems installed in accordance with RESISTO
published installation instructions and the Limitations / Conditions of Use herein. The following RESISTO
membranes make up the subject systems.
TABLE 1:ROLL-GOODS FOR MODIFIED BITUMEN ROOF SYSTEMS
Type Product Material Standard Plant(s)
Reference Type Grade
MODIFIED SOPRA-G ASTM D4601 II N/A OH
Base Sheets RESISTOFLEX ASTM D4601 II N/A MS,OH
SA Nail Base ASTM D4601 II N/A MS
RESISTO LB1236 ASTM D1970 N/A N/A MS,OH,QC
Beacon Roofing"TRI-BUILT Sand-R ASTM D1970 N/A N/A MS,OH,QC
SA Shingle Underlayment"
PrimeSource Building Products ASTM D1970 N/A N/A MS,OH,QC
"Grip-Rite Eave&Valley Protector"
Base Ply SRS Distribution'TopShield ICE&
WATER DEFENDER" ASTM D1970 N/A N/A MS,OH,QC
SA Smooth Ply 40 ASTM D1970 N/A N/A QC
SA Base ASTM D6163 I S OH,QC
BITUTAK MB SMOOTH ASTM D6222 I S MO
SA Cap GR ASTM D6163 I G OH
SA Cap FR GR ASTM D6163 I G OH
Cap Ply BITUTAK MB SMOOTH ASTM D6222 I S MO
BITUTAK MB MINERAL ASTM D6222 I G MO
5. LIMITATIONS:
5.1 This is a Building Code Evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer
of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions(i.e., Broward and Miami-
Dade Counties).
5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 This Evaluation Report does not include evaluation of roof edge termination. Refer to FBC 1504.5 for requirements
and limitations regarding edge securement for low-slope roofs.
5.6 Refer to FBC 1512 for requirements and limitations regarding recover installations.
5.6.1 For mechanically attached components over existing roof decks,fasteners shall be tested in the existing deck for
withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum
requirements for the system. Testing shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard
TAS 105.
5.6.2 For bonded insulation or membrane over existing substrates in a re-roof(tear off) or recover installation, the
existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any
surface conditions exist that bring system performance into question, field uplift testing in accordance with
ANSI/SPRI IA-1,ASTM E907,FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall
be conducted on mock-ups of the proposed new roof assembly.
NEMO ETC,LLC Evaluation Report 7215.06.14-1110
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL17084=R10
RESISTO,a division of Soprema,Inc. Revision 10:12/16/2020
Page 3 of 4
NMEMO I etc.
5.6.3 For bonded insulation or membrane over existing substrates in a recover installation,the existing roof system shall
be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having
Jurisdiction,as documented through field uplift testing in accordance with ASTM E907,FM Loss Prevention Data
Sheet 1-52 or Testing Application Standard TAS 124.
5.7 Refer to Appendix 1 for system attachment requirements for wind load resistance.
5.7.1 "MDP"=Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,
and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already
been applied).Refer to FBC 1609 for determination of design wind loads.
5.7.2 For mechanically attached components or partially-bonded insulation, the maximum design pressure for the
selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with
FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design
professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDi, FM Loss
Prevention Data Sheet 1-29,Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137.
Assemblies marked with an asterisk*carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data
Sheet 1-29(February 2020)for Zone 2/3 enhancements.
5.7.3 For assemblies with all components fully bonded in place,the maximum design pressure for the selected assembly
shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis
is permitted for these systems.
5.8 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61620-3.
Refer to the Product Approval of the component manufacturer for components listed in Appendix 1 that are
produced by a Product Manufacturer other than the report holder on Page 1 of this Evaluation Report.
INSTALLATION:
RESISTO Modified Bitumen Roof Systems shall be installed in accordance with RESISTO published installation
instructions,subject to the Limitations/Conditions of Use noted herein.
REQUIREMENts-
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
�8. MANUFACTURING PLANTS.,
Contact the named QA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
QUALITY9.
UL LLC—QUA9625;(414)248-6409,.karen.buchmann@ul.com
-THE SIX(6)PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT-
NEMO ETC,LLC. Evaluation Report 7215.06.14-1110
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL17084-R10
RESISTO,a division of Soprema,Inc. Revision 10:12/16/2020
Page 4 of 4
ONEMOjetc.
TABLE DECK APPLICATION TYPE DESCRIPTION PAGE
SA Wood New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 2
1B Wood New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 3
1C Wood New,Reroof(Tear-Off)or Recover C-1 Mechanically Attached Insulation,Bonded Roof Cover 3
1D Wood New,Reroof(Tear-Off)or Recover D-2 Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 4
lE Wood New or Reroof(Tear-Off) E-2 Non-Insulated,Meth.Attached Base Sheet(nails),Bonded Roof Cover 4-5
1F Wood New,Reroof(Tear-Off)or Recover E-2 Non-Insulated,Mech.Attached Base Sheet(screws&plates),Bonded Roof Cover 6
SG Wood New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 6
The following notes apply to the systems outlined herein:
1 The roof system evaluation herein pertains to above-deck roof components.Roof decks and structural members shall be In accordance with FBC requirements to the satisfaction of the Authority Having
Jurisdiction.
2 Fasteners shall be of sufficient length for the following engagements:
Wood Deck: Min.0.75-inch plywood penetration or minimum 1-inch wood plank embedment.
3 Unless otherwise noted,insulation may be any one layer or combination of FBC Approved(Local or Statewide)board(s)that meet FBC 1505 and,for foam plastic,FBC Chapter 26,when Installed with the roof
cover.
4 Minimum 200 psi,minimum 2-inch thick FBC Approved lightweight insulating concrete may be substituted for rigid insulation board for System Types B-1,C-1,C-2,D-1 or D-2,whereby fasteners are installed
through the lightweight insulating concrete to engage the structural deck.The structural deck shall be of equal or greater type,thickness and strength to the steel and structural concrete deck listings.Roof
decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.This is a wind uplift resistance allowance and does not purport to address non-
wind-uplift-related issues,such as deck venting or moisture levels within the LWIC and the potential effect on overlying components.
5 Preliminary insulation attachment for System Type D:Unless otherwise noted,refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1.29(February 2020).
6 Unless otherwise noted,insulation adhesive application rates are as follows.Ribbon or bead width is at the time of application;the ribbons/beads shall expand as noted in the manufacturer's published
Instructions.
;r RESISTOBOND: Continuous 0.5 to 0.75-inch wide ribbons,max.12-inch o.c.
DuPont INSTA STIK Quik Set Insulation Adhesive(INSTA STIK): Continuous 0.75 to 1-inch wide ribbons,max.12-Inch o.c.
lr OMG OlyBond 5DO: Continuous 0.75 to 1-inch wide ribbons,max.12-inch o.c.
Note.,When multiple loyers(s)of insulation and/or coverboard are installed in ribbon-applied adhesive,board joints shall be staggered.
Note:The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing.
7 Unless otherwise noted,all insulations are flat-stock or taper board of the minimum thickness noted.
8 For adhered roof insulation and board-size:Unless otherwise noted,refer to Section 2.2.10.6.2 of FM Loss Prevention Data Sheet 1-29(February 2020).
9 For mechanically attached components or partially-bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in
accordance with FBC Chapter 16.Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria.Commonly used methods are
ANSI/SPRI WDl,FM Loss Prevention Data Sheet 1-29,Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137.Assemblies marked with an asterisk*carry the limitations set forth in
Section 2.2.10.1 of FM Loss Prevention Data Sheet 1.29(February 2020)for Zone 2/3 enhancements.
SO For assemblies with all components fully bonded,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16.No
rational analysis is permitted for these systems.
NEMO ETC,LLC Evaluation Report 7215.06.14-R30 for FL17084-RlO
Certificate of Authorization N32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION Revision 10:12/16/2020
02019 NEMO ETC,LLC RESISTO,a division of Soprema,Inc.;(819)478-2400 Appendix 1,Page 1 of 6
ONEMOletc.
11 For mechanically attached components over existing decks,fasteners shall be tested in the existing deck for withdrawal resistance.A qualified design professional shall review the data for comparison to the
minimum requirements for the system.Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105.
12 For bonded insulation or membrane over existing substrates in a re-roof(tear off)or recover installation,the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be
installed.If any surface conditions exist that bring system performance into question,field uplift testing in accordance shall be conducted on mock-ups of the proposed new roof assembly.For bonded insulation
or membrane over existing substrates in a recover installation,the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having
Jurisdiction,as documented through field uplift testing.Field uplift testing shall be in accordance with ASTM E907,FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124.
13 Refer to FRC 1511 for requirements and limitations regarding recover installations.For Structural Concrete Deck or Recover Applications using System Type C-1,C-2,D-1 or 0-2,the insulation is optional.
Alternatively,an FBC Approved insulation board or coverboard may be used as a separation layer.Board products shall be preliminarily attached prior to roof cover installation(Note 5 herein).The separator
component shall be documented as meeting FBC 1505 and,for foam plastic,FBC Chapter 26,when installed with the roof cover in Recover applications.
14 Lightweight insulating concrete(LWIC)shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction.For systems where specific LWIC is referenced,refer to current
LWIC Product Approval for specific deck construction and limitations.Unless otherwise noted,for systems where specific LWIC is not referenced,the minimum design mix shall be 300 psi.In all cases,the
minimum top-coat thickness is 2-inches.For LWIC over structural concrete,reference is made to FBC Section 1917.4.1,Point 1.For"pre-existent"LWIC references,listings were established through testing over
lightweight concrete cast using only foaming agent(ASTM C896),water and Portland cement(ASTM C350),with no proprietary additives,in accordance with procedures adopted by Miami-Dade RCCO(FBC
CER1592).Use of these listings in new construction or re-roof(tear-off)applications is at the discretion of the Designer or Record and Authority Having Jurisdiction.
15 For bonded membrane applications,refer to the tables herein.The following are acceptable alternates to the listed membranes.
ACCEPTABLE ALTERNATES
RESISTO Product Alternate
Beacon Roofing"TRI-BUILT Sand-R SA Shingle Underlayment"
RESISTO L81236 PrimeSource Building Products"Grip-Rite Eave&Valley Protector"
SRS Distribution'TopShield ICE&WATER DEFENDER"
16 A slip-sheet of Modified Sopra-G or other approved ASTM D4601,Type II fiberglass base sheet may be loose laid atop the wood deck prior to the installation of overlying mechanically fastened components with
no adverse effect on system performance.
17 "MOP"x Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads.Refer to FBC 1609 for determination of design wind loads
VSTEMTYPE A�L-BONDED INSULATION,BONDED ROOF C
QVER
Base Insulation Layer Top Insulation Layer(s) Roof Cover(Note 15)
System Deck MDP
No. (Note 1) Type Attach Type Attach Primer Base Ply Ply Cap Ply (Psf)
(Notes 6,7,8) (Notes 6,7,81
APA rated,7/I6 CAT,0.418 in., Min.1.5-inch RESISTOBOND, (Optional) RESISTOBOND, (Optional) (Optional)
RESISTO BITUTAK MB SMOOTH
W 1 Exposure 1 OSS,min.15/32" ACFoam 11,SOPRA- INSTA STIK or Additional INSTA STIK or RESISTO L BITUTAK MB
B1236,self- or BITUTAK MB -52.5
APA rated plywood or nominal ISO s,H-Shield or OlyBond 500, layers(s)base OlyBond 500, EXTERIOR SMOOTH,torch-
1"T&G wood plank SOPRA-ISO r 12"o.c. insulation 12"o.c. PRIMER adhering applied MINERAL,torch-applied
APA rated,7/16 CAT,0.418 in., Min.1.5-inch RESISTOBOND, (Optional) RESISTOBOND, (Optional) (Optional)
RESISTO BITUTAK MB SMOOTH
W 2 Exposure 1 OSO,min.I5/32" ACFoam 11,SOPRA- INSTA STIK or Additional INSTA STIK or RESISTO BITUTAK MB
LB1236,self- or BITUTAK MB -105.0
APA rated plywood or nominal 150 s,H-Shield or OlyBond 500, layers(s)base OlyBond 500,6" EXTERIOR SMOOTH,torch-
1"T&G wood plank SOPRA-ISO r 6"O.C. insulation O.C. PRIMER adhering applied MINERAL,torch-applied
NEMO ETC,LLC Evaluation Report 7215.06.14-RIO for FL17094-RSO
Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION Revision 10:12/16/2020
02019 NEW ETC,LLC RESISTO,a division of Soprema,Inc.;(819)478.2400 Appendix 1,Page 2 of 6
ONEMOjetc.
TABLE it:WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF)
SYSTEM TYPE A-2: •ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER
System
Anchor Sheet Base Insulation Layers) Top Insulation Layer Roof Cover(Note 15) MDP
No. Noe 1 Type Fasteners Attach Type Attach Attach Primer Base PI PI Ca PI (psf)
( ) (Note 11) Yp (Notes 6,7,8) Type (Notes 6,7,81 Y Y R Y
APA rated,7/16 8-inch o.c.at 4-
32 ga.,1-5/B-
CAT,0.418 In., inch wide side Min.1.5-inch (Optional) (Optional) BITUTAK MB
Exposure 1 OSB, inch diameter laps and 8-inch ACFoam II, RES A STIK or Additional RES A STIK or (Optional) RESIST, BITUTAK MB SMOOTH or
tin caps with INSTA STIK or INSTA STIK or RFSISTO L81236,
W-3. min.15/32"APA SA Nail Base o.c.at three(3) SOPRA-I50 s, layers(s) SMOOTH, BITUTAK MB -30.0•
12 ga. OlyBoC. SOD, OlyOond 500, EXTERIOR self-
ratedplywood equally spaced H-Shield or base torch- MINERAL,
or nominal 1' annular ring rows in the center SOPRA-ISO r 12"o.e. insulation 12"o.c PRIMER adhering applied torch-applied
T&G wood plank shank nails of the sheet
APA rated,7/26 32 ga.,1-5/8- 6-Inch o.c.at 4-
CAT,0.4381n., inch diameter inch wide side Min.1.5-inch (Optional) (Optional)) BITUTAK MB
(Optional) RESISTO
Exposure 1 OSB, laps and 6-inch ACFoam II, Additional BITUTAK MB SMOOTH or
tin caps with INSTA'STIK,12' INSTA STIK,12" EXTERIOR
self- ,
W-4. min.15/32"APA RESISTOFLEX o.c.at three(3) SOPRA-ISO s, layers(s) SMOOTH, BITUTAK MB -37.5•
12 ga. O.C. O.C. EXTERIOR self- MINERAL,
rated plywood equally spaced H-Shield or base torth-
or nominal 1" annular ring rows in the center SOPRA-ISO r insulation PRIMER adhering applied torch-applied
T&G wood plank shank nails of the sheet
APA rated,7/16 6-inch o.c.at 4
32 ga.,1-5/8-
CAT,0.418 in., inch wide side Min.1.5-inch (Optional) (Optional) BITUTAK MB
Inch diameter (Optional) RESIST,
Exposure 1 OSB, laps and 6-inch ACFoam II, Additional BITUTAK MB SMOOTH or
tin caps with INSTA STIK,6' INSTASTIK,6" RESISTO LB1236,
W-5. min.15/32"APA RESISTOFLEX o.c.at four(4) SOPRA-ISO s, layers(s) SMOOTH, BITUTAK MB -75.0
12 ga. O.C. O.C. EXTERIOR self-
rated plywood equally spaced H-Shield or base torch- MINERAL,
or nominal 1' annular ring rows in the center SOPRA-ISO r insulation PRIMER adhering applied torch-applied
T&G wood plank I
shank nails of the sheet
e•e eCONSTRUCTION, •ee • •
ATTACHEDSYSTEMTYPEC-1.,MECHANICALLY INSULATION,BONDED ROO
Top Insulation Layer Roof Cover(Note 25)
System -. Deck Base Insulation MDP
No. (Note 1) -(Note 13) Type Fasteners - Attach Primer Base Ply Ply Cap Ply (Psf)
(Note 11)
Min.15/32-inch Soprema a12 DP (Optional)
(Optional)One or more Min.1.5-inch ACFoam II,
APA rated Fasteners with 1 per 1.6 RESISTOTSA Smooth ly ffGR
or SA Cap FR
plywood at max. layers,anySOPRA-ISO s,H-Shield, Soprema 3"Metal it, EXTERIOR0 None -67.5
24-Inch spans combinati ose laid SOPRA-ISO r Insulation Plates PRIMER
Min.15/32-Inch Soprema Nl2 DP (Optional) (Optional) �
(Optional)One or more Min.1.5-inch ACFoam II, RESISTO B B SMOOTH
APA rated Fasteners with 1 per 1.6 RESIST, BITUTAK MB
W-7. layers,any SOPRA-ISO s,H-Shield, r L81236,self- or BITUTAK MB -67.5
plywood at max. Soprema 3"Metal ft EXTERIOR SMOOTH,torch-
24-inch spans combination,loose laid SOPRA-ISO r Insulation Plates PRIMER adhering applied MINERAL,torch-applied
MEMO ETC,LLC Evaluation Report 7215.06.14-R10 for FL17084-RIO
Certificate of Authorization N32455 Iry EDITION(2020)FBC NON-HVHZ EVALUATION Revision 10:12/16/2020
02019 NEMO ETC,LLC RESISTO,a division of Soprema,Inc..(819)478-2400 Appendix 1,Page 3 of 6
)
ONEMOletc.
TABLE • WOOD DECKS— ••e sRECOVER
SYSTEM TYPE D-2:INSULATED,MECHANICALLY ATTACHED BAsESHEET,BONDEDROOFtOVER
(Note Base Sheet Roof Cover(Note 15) MDP
System Deck(Note 1)- Insulation Layer(s) Fasteners
No. (Note 331 Type _ Attach Base Ply Ply Cap Ply IPsfl
(Note 11)
APA rated,7/16 CAT,0.418 (Optional)
One or more layers,min. Trufast 812 DP with 8-inch o.c at the 4-inch laps BITUTAK MB SMOOTH
W-8. Trufast 3"Metal and 8-inch o.c.at three(3),
in.,Exposure 1 OSS,min. SA Nail RESISTO L81236, BITUTAK MB or BITUTAK MB -82.5
1-inch,any combination,
15/32"APA rated plywood or Base self-adhering SMOOTH,torch-
nominal 1"T&G wood plank loose-laid Insulation Plates equally spaced center rows applied MINERAL,torch-applied
APA rated,7/16 CAT,0.418 (Optional) (Optional)
One or more layers,min. Trufast p12 DP with 8-inch o.c.at the 4-inch laps BITUTAK MB SMOOTH
In.,Exposure 1 OSB,min. MODIFIED BITUTAK MB BITUTAK MB
W-9. 1-inch,any combination, Trufast 3"Metal and 8-Inch o.c at three(3), or BITUTAK MB -120.0
15/32"APA rated plywood or SOPRA-G SMOOTH,torch- SMOOTH,torch-
nominal I"T&G wood plank loose-laid Insulation Plates equally spaced center rows applied applied MINERAL,Larch-applied
TABLE IE:WOOD DE CKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF)
• • MECHANICALLYATTACHED: BONDED ROOCOVER
Base Sheet Roof Cover(Note 15)
System Deck(Note 1) 'Fasteners Primer MOP
No. Base Attach Base Ply Primer Ply Cap Ply (P )
(Note 13)
8-inch o.c.at 4-Inch wide
32ga.,ertin capnchs
(Optional)
APA rated,7/16 CAT, side laps and 8-inch o.c.at RESISTO BITUTAK MB SMOOTH or
SA Nail 12 ga. annul caps with BITUTAK MB
W-10. 0.416 in.,Exposure 1 three(3)equally spaced None L01236,self- None BITUTAK MB MINERAL,torch- -30.0'
Base 12 ga.annular ring SMOOTH,torch-
OSB shank nails rows in the center of the adhering applied applied
sheet
SOPRA-G 32 ga.,1-5/8-inch 6-inch o.c.at the 4-inch
Min.7/16-inch O58 or RESISTO RESISTO
W-11. min.15/32-inch APA or diameter tin caps with laps and 6-inch o.c.at four EXTERIOR SA Base EXTERIOR None SA Cap GR or SA Cap FR GR -37.5•
rated plywood MODIFIED 11 ga.annular ring (4),equally spaced, PRIMER PRIMER
SOPRA-G shank nails staggered center rows
32 ga.,1-5/84nch 7-inch o.c.at the 4-inch RESISTO RESISTO
Min.19/32-inch APA diameter tin caps with laps and 7-Inch o.c.at
W-12. rated plywood SOPRA-G 11 ga.annular ring three(3),equally spaced, EXTERIOR SA Base EXTERIOR None SA Cap GR or SA Cap FR GR -37.5
PRIMER PRIMER
shank nails staggered center rows
32 ga.,1-5/8-inch 8-inch o.c.at the 4-Inch
Min.15/32-inch APA SA Nail diameter tin raps with laps and 8-inch o.c.at (Optional)SA
W-13. rated plywood Base 11 ga.annular ring three(3).equally spaced, None Smooth Ply 40 None None SA Cap GR or SA Cap FR GR -45.0
shank nails staggered center rows
32 ga.,1-5/8-inch 8-inch o.c.at the 4-inch RESISTO (Optional)
BITUTAK MB SMOOTH or
W-14.
Min.15/32-inch APA SA Nail diameter tin caps with laps and 8-inch o.c.at BITUTAK MB
rated plywood Base 11 ga.annular ring three(3),equally spaced, None LdherinB1236,self- None SMOOTH,torch- BITUTAK MB MINERAL,torch- -45.0
shank nails staggered center rows adhering applied applied
it
NEMO ETC,LLC Evaluation Report 7215.06.14-R10 for FL17084-RIO
Certificate of Authorization#32455 791 EDITION(2020)FBC NON-HVHZ EVALUATION Revision 10:12/16/2020
02019 NEMO ETC,LLC RESISTO,a division of Soprema,Inc.;(819)478-2400 Appendix 1,Page 4 of 6
i
i
ONEMOletc.
TABLE 1E'WOOD r CONSTRUCTION •ee e
NON-INSULATED, MECHANICALLY ATTACHED SON r D 190OF COVER
Base Sheet Roof Cover(Note 15)
System MOP
Deck Note 1
( ) Fastener Primer
No. Base Attach Base Ply Primer Ply Cap Ply (Psfl
(Note 11)
32 ga.,1-5/8-inch 6-inch o.c,at the 4-inch
Min.15/32-inch OSB RESISTO RESISTO
W-15. or min.15/32-Inch SOPRA-G diameter tin caps with laps and 6-Inch o.c.at four EXTERIOR SA Base EXTERIOR None SA Cap GR or SA Cap FR GR -45.0
APA rated plywood 11 ga.annular ring (4),equally spaced, PRIMER PRIMER
shank nails staggered center rows
32 ga.,1-5/8-inch 6-inch o.c.at the 4-inch (Optional)
RESISTO BITUTAK MB SMOOTH or
W-16. Min.15/32-inch APA SA Nail diameter tin caps with laps and 6-inch o.c.at four None ,self- None BITUTAK MB BITUTAK MB MINERAL,torch- -52.5
rated plywood Base 12 ga.annular ring (4),equally spaced, a SMOOTH,torch-dheri
shank nails staggered center rows adhering applied applied
Min.19/32-inch APA 32 ga.,1-5/8-inch 8-inch o.c.at the 4-inch
rated plywood or SA Nail diameter tin caps with laps and 8-inch o.c.at (Optional)SA
W-17. nominal 1" None
wood Base 11 ga.annular ring three(3),equally spaced None Smooth Ply 40 None None SA Cap GR or SA Cap FR GR -60.0
plank shank nails center rows
Min.19/32-inch APA 32 ga.,1-5/8-inch 8-Inch o.c.at the 4-Inch (Optional)
RESISTO BITUTAK MB SMOOTH or
rated plywood or SA Nail diameter tin caps with laps and 8-inch o.c.at BITUTAK MB
W-18. nominal 1" one
wood Base 11 ga.annular ring three(3),equally spaced None adheri,Belt- None SMOOTH,torch- BITUTAK MB MINERAL,torch- -60.0
plank shank nails center rows adhering applied applied
APA rated,7116 CAT, GAP
0.418 in.,Exposure 1 Organic 6-inch o.c.at the 3-inch (Optional) (Optional) BITUTAK MB SMOOTH or
Simplex MAXX Cap laps and 6-inch o.c.at BITUTAK MB BITUTAK MB
W-19. OSB or min.15/32- Base None None BITUTAK MB MINERAL,torch- -60.0
Fastener three rows
equally spaced SMOOTH, SMOOTH,torch- lied
plywood (h43)
inch APA rated Sheet center rows torch-applied applied aPP•
Min.19/32-inch APA 32 ga.,1-5/8-inch 6-inch o.c.at the 4-inch
rated plywood or SA Nail diameter tin caps with laps and 6-inch o.c.at (Optional)SA
W-20' nominal 1"T&G wood Base 0.120"x 1.25"ring three(3),equally spaced None Smooth Ply 40 None None SA Cap GR or SA Cap FR GR -90.0
plank shank roofing nails center rows
Min.19/32-inch APA 32 ga.,1-5/8-inch 6-inch o.c.at the 4-Inch (Optional)
RESISTO BITUTAK MB SMOOTH or
rated plywood or SA Nail diameter tin caps with laps and 6-inch o.c.at BITUTAK MB
W 21, nominal 1"T&G wood Base 0.120"x 1.25"ring three(3),equally spaced None LB1236,self- None SMOOTH,torch- BITUTAK MB MINERAL,torch- -90.0
plank shank roofing nails center rows adhering applied Iapplied
Min.19/32-inch APA 32 ga.,1-5/8-inch 4-inch o.c.at the 4-inch
rated plywood or SA Nail diameter tin caps with laps and 4-inch o.c.at tour (Optional)SA
W-22. nominal 1"T&G wood Base 0.120"x 1.25"ring (3),equally spaced center None Smooth Ply 40 None None SA Cap GR or SA Cap FR GR -105.0
plank shank roofing nails rows
Min.19/32-inch APA 32 ga.,1-5/8-Inch 4-inch o.c.at the 4-inch RESISTO (Optional) BITUTAK MB SMOOTH or
rated plywood or SA Nail diameter tin caps with laps and 4-inch O.C.at four BITUTAK MB
W 23. nominal 1"T&G wood Base 0.120"x 1.25"ring (3),equally spaced center None adheri,self- None SMOOTH,torch- BITUTAK MB MINERAL,torch- -105.0
plank shank roofing nails rows adhering applied applied
t
MEMO ETC,LLC Evaluation Report 7215.06.14-R10 for FL17094-R30
Certificate ofAutharization d32455 7'EDITION(2020)FBC NON-HVHZ EVALUATION Revision 10:12/16/2020
02019 NEMO ETC,LLC RESISTO,a division of Soprema,Inc.;(819)478-2400 Appendix 1,Page 5 of 6
,R NEMo etc.
... .
BONDED.ROOF COVER
System Base Sheet Roof Cover(Note 15)
Deck(Note 11 Fastener Primer MDP
No. Base Attach Base Ply Primer Ply Cap Ply (Psfl
(Note 1])
Min.19/32-inch APA Trufast#12 DP with 8-Inch o.c,at the 4-inch laps
rated plywood or SA Nail (Optional)SA
W-24. nominal 1"7&G wood Base Trufast 3"Metal and 8-inch o.c.at three(3), None Smooth Ply 40 None None SA Cap GR or SA Cap FR GR -127.5
plank Insulation Plates equally spaced center rows
Min.19/32-inch APA (Optional)
rated 1 Trufast#12 DP with 8-inch o.c,at the 4-inch laps RESISTO BITUTAK MB SMOOTH or
plywood or SA Nail BITUTAK MB
W 25. nominal 1"T&G wood Base Trufast 3"Metal and flinch spaced
at three rows
None adhering
,self- None SMOOTH,torch- BITUTAK MB MINERAL,torch- -127.5
plank insulation Plates equally spaced center rows adhering applied applied
SYSTEM TYPE F:NOWINSULATED,BONDED ROOF
System Deck(Notes 1&22) Primer Roof[over(Note 15) MDP(psf)
No. Base Ply Primer Ply Cap Ply
W 26 Min.7/16-inch APA rated OSB or min. RESISTO EXTERIOR SA Base RESISTO EXTERIOR None SA Cap GR or SA Cap FR GR -45.0
15/32-Inch APA rated plywood PRIMER PRIMER
W-27. Min.15/32-inch APA rated OSB None SA Smooth Ply 40 None None SA Cap GR or SA Cap FR GR -67.5
W-28. Min.15/32-inch APA rated OSB RESISTO EXTERIOR SA Smooth Ply 40 None None SA Cap GR or SA Cap FR GR -75.0
PRIMER
APA rated,7/16 CAT,0.418 in.,Exposure (Optional)RESISTO RESISTO LB1236, (Optional)BITUTAK MB BITUTAK MB SMOOTH or BITUTAK MB
W29' None 105B pl
ywood min.15/32"APA rated ywood EXTERIOR PRIMER self-adhering SMOOTH,[arch-applied MINERAL,torch-applied -97.5
W-30. Min.15/32-inch APA rated plywood None SA Smooth Ply 40 None None SA Cap GR or SA Cap FR GR -105.0
W-31. Min.15/32-inch APA rated I RESISTO EXTERIOR
plywood PRIMER SA Smooth Ply 40 None None SA Cap GR or SA Cap FR GR -112.5
(Optional)RESISTO RESISTO LB1236, (Optional)BITUTAK MB BITUTAK MB SMOOTH or BITUTAK MB
W-32. Nominal 1"T&G wood plank None EXTERIOR PRIMER self-adhering SMOOTH,torch-applied MINERAL,torch-applied -135.0
MEMO ETC,LLC Evaluation Report 7215.06.14-R10 for FL17094-R10
Certificate of Authorization A32455 7TM EDITION(2020)FBC NON-HVHZ EVALUATION Revision 10:12/16/2020
02019 NEMO ETC,LLC RESISTO,a division of Soprema,Inc.,(819)478.2400 Appendix 1,Page 6 of 6