Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED, design pressure calcs
PARADISE EXTERIORS "Building Our Quality Reputation One Customer At A Time" SCC131150472 Property Information Building Information Owner: WILLIAM & PATRICIA RODGERS Wind Gone: 170 MPH. Address: 355 PALMS AVE Exposure Category: C FORT PIERCE, FL 34982 Minimum Building Dimension: 29 ft. Mean Roof Height: 12 ft, Risk Category: 1f E Design Prcssure Calculations Opening Number Location Zo�ie Device Width (in) E Device ! Height (in) Device i 3 i Elevation (ft) ?� Max Positive 'I Pressure (13sf) Max Negative Pressure (psf) .._.........._....._.._............... ........ .._.-- --- - - ...._......_.._.._._...__...... W -—_.. } ........-.. I Int 52 37 7 37.1 -40.3 2 End 35 36 7 37.8 -50.6 3 lilt 105 79 7 33.5 -36.7 4 ....... ......... Iilt 52 37 7 37.1 -40.3 5 - Int _ 72 79 7 34.4 -37 6 6 Int --- --- 35 ......... -- .................... ... 62 - — 7 ---- - 36.8 - -40 0 7 End. 35 61 7 36.8 48.7 8 - — - End - - 51 -- 24 - -. ... .... _....................................... 7 - - - ---- 37.8 -- - -50.6 9 - End 25 37 7 37.8 -50.6 Prepared in rxro)-danve nvilh,• _ISCE 7-16, Chapter 30. Wind Lofty - Components and Cladding. 71h Edition {2020) Florida Building Code. Page 1 of 1