HomeMy WebLinkAboutEnergy CodeFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 18 Block 1 Waterstone 1720 AGR
Builder Name: ADAMS HOMES
Street: 5380 Lugo Street
Permit Office:
c
F�12 �o
City, State, Zip: Fort Pierce , FL, 34951
Permit Number:
Owner:
Jurisdiction: 661000
8T,.L cle County, Permitting
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate
1. New construction or existing New (From Plans)
10. Wall Type01665.3 sgft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1371.10 ft2
b. Frame - Wood, Adjacent
R=13.0 294.17 ft2
3. Number of units, if multiple family 1
c. NIA
R= ft2
4. Number of Bedrooms 3
d. NIA
R= ft2
5. Is this a worst case? No
11. Ceiling Types (1740.0 sgft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1720.00 ft2
6. Conditioned floor area above grade (ft2) 1720
b. Knee Wall (Vented)
R=19.0 20.00 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(181.4 sgft.) Description Area
12. Ducts
R ft2
a. Sup: Attic, Ret: Attic, AH: Main
6 344
a. U-Factor: Dbl, U=0.33 113.75 ft2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 32.38 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
28.4 SEER:15.00
c. U-Factor: Dbl, U=0.55 17.78 ft2
SHGC: SHGC=0.70
Area Weighted Average Overhang Depth: 3.885 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.279
a. Electric Heat Pump
28.2 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons
9. Floor Types (1720.0 sqft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 1720.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
Pstat
Glass/Floor Area: 0.105 Total Proposed Modified Loads: 52.53
PASS
Total Baseline Loads: 52.79
I hereby certify that the plans ifications cover e
Re-v+i&N of the plans and
tuE Sp,
this calculation are in comp n o ' nergy
specifications covered by this
D F
a p
Code.
calculation indicates compliance
�i? �i;,' _ =,cam .��
with the Florida Energy Code.
�, /irri '��� t:= „ O
PREPARED BY:
Before construction is completed
` " "p 4.
DATE: n1-2R_2m1 Winn Keomany
this building will be inspected for,.
compliance with Section 553.908
l;
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
5
with the Florida EQt[2y Code.
COSv
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure -qualifies as
certified factory -sealed in accordance with R403.3.2.1.
• - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
fJ� - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.060 Qn for whole house.
1/26/2021 2:39 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5
FORM R405-2020 INPl1T SUMMARY r141=r[ l ICT RGpnaT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 18 Block 1 Waterstone 17 Bedrooms: 3
User Conditioned Area: 1720
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Detached
New (From Plans)
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
Lot Information
18
Waterstone
5380 Lugo Street
St. Lucie
Fort Pierce ,
FL , 34951
CLIMATE
/
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299
58 Medium
BLOCKS
Number
Name
Area Volume
1.
Block1
1720 15480
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
1720 15480 Yes 4
3 1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 171.5 ft 0
1720 ft2 ----
0.26 0 0.74
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt
Barr Absor. Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Gable or Shed Composition shingles 1923 ft2 430 ft2 Medium
N 0.85 N 0.85 No 0 26.57
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 1720 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
2
3
Knee Wall (Vented)
Knee Wall (Vented)
Under Attic (Vented)
Main 19 Batt
Main 19 Batt
Main 30 Blown
5 ft2 0.11
15 ft2 0.11
1720 ft2 0.11
Wood
Wood
Wood
1/26/2021 2:39 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5
FORM R405-2020 INPI IT SI IMMAPV r41rrL[il icT Qoonor
WALLS
Ornt
Adjacent
TO MIMI Titpe_
Space
Cavity Width
Height
Sheathing Framing Solar Below
_ a
1 N
Exterior
Concrete Block - Int Insul
Main
4.1 32
4
8 5
272.1 ft2
0
0 0.6
0
2 N
Exterior
Concrete Block - Int Insul
Main
4.1 4
5
9 0
39.8 ft2
0
0 0.6
0
3 N
Exterior
Concrete Block - Int Insul
Main
4.1 11
0
8 0
88.0 ft2
0
0 0.6
0
4 E
Exterior
Concrete Block - Int Insul
Main
4.1 5
9
9 0
51.8 ft2
0
0 0.6
0
5 E
Exterior
Concrete Block - Int Insul
Main
4.1 12
0
8 0
96.0 ft2
0
0 0.6
0
6 S
Exterior
Concrete Block - Int Insul
Main
4.1 19
9
8 9
172.8 ft2
0
0 0.6
0
7 S
Exterior
Concrete Block - Int Insul
Main
4.1 26
1
9 0
234.8 ft2
0
0 0.6
0
8 S
Exterior
Concrete Block - Int Insul
Main
4.1 13
6
8 0
108.0 ft2
0
0 0.6
0
9 W
Exterior
Concrete Block - Int Insul
Main
4.1 13
9
9 1
124.9 ft2
0
0 0.6
0
10 W
Exterior
Concrete Block - Int InsuI
Main
4.1 20
4
9 0
183.0 ft2
0
0 0.6
0
11 -
Garage
Frame - Wood
Main
13 29
5
10 0
294.2 ft2
0
0.23 0.01
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft In
Ft In
1
-
Wood Main
None
.25
2
8
6 8
17.8 ft2
2
E
Insulated Main
None
.25
3
6 8
20 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
# Ornt ID
Frame Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1 N
1
Vinyl Low-E Double
Yes
0.33 0.23
N
16.2 ft2
1 ft 4 in
0 ft 10 in
None
Exterior 5
2 N
1
Vinyl Low-E Double
Yes
0.36 0.29
N
6.9 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
3 E
4
Vinyl Low-E Double
Yes
0.33 0.31
N
4.0 ft2
11 ft 10 in
0 ft 8 in
None
None
4 E
4
Vinyl Low-E Double
Yes
0.33 0.31
N
6.7 ft2
11 ft 10 in
2 ft 9 in
Drapes/blinds
None
5 E
5
Vinyl Low-E Double
Yes
0.33 0.21
N
32.4 ft2
1 ft 4 in
3 ft 7 in
Drapes/blinds
Exterior 5
6 S
6
Vinyl Low-E Double
Yes
0.33 0.23
N
6.9 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
7 S
6
Vinyl Low-E Double
Yes
0.33 0.23
N
16.2 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
8 S
7
Vinyl Low-E Double
Yes
0.33 0.23
N
9.8 ft2
1 ft 4 in
0 ft 10 in
None
Exterior 5
9 W
9
Vinyl Low-E Double
Yes
0.33 0.23
N
16.2 ft2
1 ft 4 in
0 ft 10 in
None
Exterior 5
10 W
9
Vinyl Low-E Double
Yes
0.33 0.23
N
16.2 ft2
11 ft 8 in
0 ft 10 in
None
Exterior 5
11 W
10
Metal Low-E Double
Yes
0.55 0.7
N
17.8 ft2
11 ft 8 in
1 ft 0 in
Drapes/blinds
None
12 W
10
Vinyl Low-E Double
Yes
0.33 0.23
N
32.4 ft2
1 ft 4 in
0 ft 10 in
None
Exterior 5
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
610ft2 610ft2
56ft
8ft
1
1/26/2021 2:39 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5
FORM R405-2020 INPUT RIIMMARY rI4I=rILCI IRT RIFanRT
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.0004
1806 99.08 186.02 .1324
7
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/
Split
Sing[ HSPF:8.5 28.2 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split
Singl SEER: 15 28.4 kBtu/hr cfm
0.75 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use SetPnt
Conservation
1 Electric None
Garage
0.94 40 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ftz
DUCTS
---- Supply ----
V # Location R-Value Area
---- Return ---- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT
QN RLF
HVAC #
Heat Cool
1 Attic 6 344 ftz
Attic
86 ftz Proposed Qn Main --- cfm 103.2 cfm 0.06 0.60
1 1
TEMPERATURES
Programable Thermostat: Y
Cooling[ Jan [ Feb Mar
Heatin[X Jan [X Feb f X� Mar
Ventin [ Jan [ Feb [X Mar
Ceiling Fans:
Apr May X Jun X Jul rj Au Se
APr May f j Jun f Jul Au�XjSeP
[ A r [ Ma [ Jun [ Jul Aug Se [X]
Oct Nov
Oct Nov
Oct X Nov
Dec
Dec
H Dec
1/26/2021 2:39 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s
.ft.
0 ftz
0 ft
0.3
Main
1/26/2021 2:39 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 5
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
5380 Lugo Street, Fort Pierce, FL, 34951
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1371.10 ft2
b. Frame - Wood, Adjacent
R=13.0
294.17 ft2
3. Number of units, if multiple family
1
c. N/A
R=
ft2
4. Number of Bedrooms
3
d. N/A
R=
ft2
5. Is this a worst case?
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
1720.00 ft2
6. Conditioned floor area (ft2)
1720
b. Knee Wall (Vented)
R=19.0
20.00 ft2
7. Windows** Description
Area
c. N/A
R=
ft2
a. U-Factor: Dbl, U=0.33
113.75 ft2
12. Ducts, location & insulation level
R ft2
a. Sup: Attic, Ret: Attic, AIR Main
6 344
�
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33
32.38 ft2
SHGC: SHGC=0.21
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: Dbl, U=0.55
17.78 ft2
a. Central Unit
28.4 SEER:15.00
SHGC: SHGC=0.70
d. U-Factor: other (see details)
17.53 ft2
SHGC: other (see details)
14. Heating systems
kBtu/hr
Efficiency
Area Weighted Average Overhang Depth:
3.885 ft.
a. Electric Heat Pump
28.2
HSPF:8.50
Area Weighted Average SHGC:
0.279
8. Skylights Description
Area
15. Hot water systems
a. U-Factor(AVG): N/A
2
ft2
a. Electric
Cap: 40 gallons
SHGC(AVG): N/A
EF:0.94
b. Conservation features
9. Floor Types
Insulation
Area
None
a. Slab -On -Grade Edge Insulation
R=0.0
1720.00 ft2
Credits (Performance method)
Pstat
b. N/A
R=
ft2
c. N/A
R=
ft2
certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: A Date:
Address of New Home:
City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
1/26/2021 2:39 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1