HomeMy WebLinkAboutProject Informationt
Manual S Compliance Report Job: Lot 18 Block 1 Waterston...
wrightsoft® Date:
Entire House By: SIR
DEL -AIR HEATING & AIR CONDITIONING
531 CODISCO WAY, SANFORD, FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web: W W W.DEL-AIR.COM
Project [nformation
For: ADAMS HOMES
5380 Lugo Street, Fort Pierce, FL 34951
Cooling Equipment
Design Conditions
design DB:
90.4OF
Sensible gain:
22025
Btuh Entering coil DB: 76.5OF
Outdoor design WB:
77.4OF
Latent gain:
4014
Btuh Entering coil WB: 63.3OF
Indoor design DB:
75.0 OF
Total gain:
26040
Btuh
Indoor FIR
50%
Estimated airflow:
947
cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment. type:
SplitASHP
Carrier
Model: 25HBC530AP03+FX4DNF031 L00
Actual airflow:
947
cfmSensible
LRECEIVEDManufacturer:
�Latent
capacity:
22678
Btuh
103% of load
capacity:
4723
Btuh
118%of loadTotal
capacity:
27400
Btuh
105%of load SHR: 83%
ty, Permitting
Heating Equipment
Design Conditions
Outdoor design DB: 41.0 OF Heat loss: 24348 Btuh
Indoor design DB: 70.0 OF
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SplitASHP
Manufacturer: Carrier Model: 25HBC530AP03+FX4DNF031 L00
Actual airflow: 947 cfm
Output capacity: 26646 Btuh 109% of load
Supplemental heat required: 0 Btuh
Backup equipment type: Elec strip
Manufacturer: Model:
Actual airflow: 947 cfm
Output capacity: 6.3 kW 88% of load Temp. rise: 21 IF
Meets all requirements ofACCA Manual S.
Entering coil DB: 69.5OF
Capacity balance: 37 OF
Economic balance: -99 OF
.` �' - wrightsoft' 2021-Jan-2614:3233
^'� aM:*o.•��,nw .��mwM Right-Sute®Uriversal202121.0.02RSU23828 Page
��...aterstone1720AGR�Lot18BIkiWaterstone1720AGR.nQ Calc=MJB Housefaces: N
Component Constructions Job: Lot 18 Block 1 Waterston...
-- wrightsoft0 Date:
Entire House By: SIR
DEL -AIR HEATING & AIR CONDITIONING
531 CODISCO WAY, SANFORD, FL 32771 Phore:407-333-2665 Fax:407-333-3853 Web: W W W.DEL-AIR.COM
Enialect Intormation
For: ADAMS HOMES
5380 Lugo Street, Fort Pierce, FL 34951
Design
Conditions
Location:
St Lucie Co Intl, FL, US
Indoor:
Indoor temperature (T)
Heating
70
Cooling
75
Elevation: 26 ft
Design TD (OF)
29
15
Latitude: 28 °N
Relative humidity (%)
30
50
Outdoor: Heating
Cooling
Moisture difference (grAb)
2.4
56.9
Dry bulb (OF) 41
90
Infiltration:
Daily range (OF) -
Wet bulb (T) -
15 (L
77
) Method
Simplified
Wind speed (mph) 15.0
7.5
Construction quality
Fireplaces
Average
0
Construction descriptions or Area U-value Insul R Htg H711A Loss Clg H711A Gain
ft� Btu"*F ftz°F/Btuh BtuMP Btuh BtutVft� Btuh
Walls
Blk wall, stucco ext, r-4.1 ext bd ins, 8" thk, 1/2" gypsum board int fnsh
1613-19ad: Knee wall, asphalt shingles roof mat, r-19 kw ins, 1/2" gypsum
board int fnsh
Partitions
12C-Osw. Frm wall, 1/2" gyp.bd ext, r-13 cav ins, 1/2" gypsum board int
fnsh, 2'S44' wood frm, 16" o.c. stud
Windows
2A-2ov: 2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/8"
thk; NFRC rated (SHGC=0.23); 1.33 ft overhang (5.3 ft window ht, 0.83 ft
sep.); 6.67 ft head ht
2A-2ov: 2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/8"
thk; NFRC rated (SHGC=0.23); 50% drapes, medium; 1.33 ft overhang
(3.17 ft window ht, 0.83 ft sep.); 6.67 ft head ht
2X2ov: 2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/8"
thk; NFRC rated (SHGC=0.21); 50% drapes, medium; 1.33 ft overhang
(5.3 ft Window ht, 3.58 ft sep.); 6.67 ft head ht
2B-2fv: 2 glazing, dr low-e outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/8"
thk; NFRC rated (SHGC=0.31); 11.83 ft overhang (1 ft window ht, 0.67 ft
sep.); 6.67 ft head ht
213-2fv: 2 glazing, clr low-e outr, air gas, vnl fan mat, clr innr, 1/4" gap, 1/8"
thk; NFRC rated (SHGC=0.31); 50% drapes, medium; 11.83 ft overhang
(6.7 ft window ht, 2.75 ft sep.); 6.67 ft head ht
n
377
0.201
4.1
5.83
2196
4.06
1530
e
85
0.201
4.1
5.83
493
4.06
343
s
483
0.201
4.1
5.83
2816
4.06
1961
w
224
0.201
4.1
5.83
1308
4.06
911
all
1169
0.201
4.1
5.83
6812
4.06
4745
e
5
0.049
19.0
1.42
7
2.59
13
s
15
0.049
19.0
1.42
21
2.59
39
all
20
0.049
19.0
1.42
28
2.59
52
276
0.091
13.0
2.64
729
1.31
362
n
16
0.330
0
9.57
156
9.90
162
w
49
0.330
0
9.57
469
26.3
1289
all
65
0.330
0
9.57
626
22.2
1451
n
7
0.330
0
9.57
66
8.52
58
s
7
0.330
0
9.57
66
8.52
58
all
14
0.330
0
9.57
131
8.52
117
e
33
0.330
0
9.57
313
21.6
707
e
4
0.330
0
9.57
38
11.6
46
e
7
0.330
0
9.57
64
9.72
65
.� -r�F wrightsc ft- 2021-Jarr2614:3213
ACCP. Right-Sute®Uriversal2021 21.0.02 RSU23828 Page 1
aterstonel720AGRtLotl8BlklWaterstorel720AGR.np Calc=MJB Housefaces: N
' 2A-2ov: 2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/8"
s
10
0.330
0
9.57
93
9.90
97
thk; NFRC rated (SHGC=0.23); 1.33 ft overhang (3.17 ft window ht, 0.83
ft sep.); 6.67 ft head ht
A 2A-2ov: 2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/8"
s
16
0.330
0
9.57
156
8.52
139
thk; NFRC rated (SHGC=0.23); 50% drapes, medium; 1.33 ft overhang
(5.3 ft window ht, 0.83 ft sep.); 6.67 ft head ht
10C-m: 2 glazing, clr low-e outr, air gas, mtl no brk frm mat, clr innr, 1/4"
w
18
0.550
0
16.0
285
12.6
226
gap, 1/8" thk; NFRC rated (SHGC=0.70); 50%drapes, medium; 11.67 ft
overhang (6.7 ft window ht, 1 ft sep.); 6.67 ft head ht
2A-2ov: 2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/8"
w
17
0.330
0
9.57
161
9.90
166
thk; NFRC rated (SHGC=0.23); 11.67 ft overhang (5.3 ft window ht, 0.83
ft sep); 6.67 ft head ht
Doors
11 JO: Door, mtl fbrgl type
a
20
0.600
6.3
17.4
350
17.6
353
11 DO: Door, wd sc type
n
18
0.390
0
11.3
201
11.4
203
Ceilings
1613-30ad: Attic ceiling, asphalt shingles roof mat, r-30 cell ins, 1/2"
1899
0.032
30.0
0.93
1763
1.69
3209
gypsum board int fnsh
Floors
22A-tpl: Bg floor, light dry soil, on grade depth
206
0.989
0
28.7
5908
0
0
c
wrright soft® 2021-Jarr2614:3233
,4cc% RigM-Srite@Uriversal 2021 21.0.02 RSU23828 Page 2
aterstone1720AGR\Lot18BIk1Waterstor)e1720AGR.np Calc=MJ8 Horsefaces: N
- - wrightsofte Project Summary
Entire House
DEL -AIR HEATING & AIR CONDITIONING
531 CODISCO WAY, SANFORD, FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web: W W W.DEL-AIR.COM
Project Information
For: ADAMS HOMES
5380 Lugo Street, Fort Pierce, FL 34951
Notes: L. S. 1-26-21 VWK
Desim. Information
Weather:
Winter Design Conditions
Outside db 41 OF
Inside db 70 OF
Design TD 29 OF
Heating Summary
Structure
20857
Btuh
Ducts
3491
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Humidification
0
Btuh
Piping
0
Btuh
Equipment load
24348
Btuh
Infiltration
Method
Construction quality
Fireplaces
St Lucie Co Inti, FL, US
Simplified
Average
0
Heatingg Cooling
Area (ft2) 1720 1720
Volume (ft3) 15844 15844
AirchangesJhour 0.38 0.20
Equiv. AVF (cfm) 100 53
Heating Equipment Summary
Make Carrier
Trade
Model 25HBC530AP03
AHRI ref 204840289
Efficiency 8.5 HSPF
Heating Input
Heating output 28200 Btuh @ 47°F
Temperature rise 27 OF
Actual air flow 947 cfm
Airflowfactor 0.039 cfm/Btuh
Static pressure 0.40 in H2O
Space thermostat
Capacity balance point = 37 OF
Backup:
Input = 6 kW, Output = 21472 Btuh,100 AFUE
Job: Lot 18 Block 1 Waterston...
Date:
By: SIR
Summer Design Conditions
Outside db
90
OF
Inside db
75
OF
Design TD
15
OF
Daily range
L
Relative humidity
50
%
Moisture difference
57
gr4b
Sensible Cooling Equipment Load Sizing
Structure
17182
Btuh
Ducts
4843
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Blower
0
Btuh
Use manufacturer's data y
Rate/swin multiplier 1.00
EquipmN sensible load 22025 Btuh
Latent Cooling Equipment Load Sizing
Structure
2841
Btuh
Ducts
1173
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Equipment latent load
4014
Btuh
Equipment Total Load (Sen+Lat) 26040 Btuh
Req. total capacity at 0.75 SHR 2.4 ton
Cooling Equipment Summary
Make Carrier
Trade
Cond 25HBC530AP03
Coil FX4DNF031L00
AHRI ref 204840289
Efficiency 12.5 EER,15 SEER
Sensible cooling
21300
Btuh
Latentcooling
7100
Btuh
Total cooling
28400
Btuh
Actual airflow
947
cfm
Airflowfactor
0.043
cfm/Btuh
Static pressure
0.40
in H2O
Load sensible heat ratio
0.85
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
.� � wrightSoft® 2021-Jarr2614.32:33
.� RigH-Sute®Uriversal 2021 21.0.02 RSU23828 page 1
'CC-P`...aterslone1720AGR\Lotl8BlkiWaterstone1720AGR.nQ Calc=W8 Hoisefaces: N
`- - wriyntsofts Right-M Worksheet
Entire House
DEL -AIR HEATING &AIR CONDITIONING
531 CODISCO WAY, SANFORD, FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web: W W W.DEL-AIR.COM
Job: Lot 18 Block 1 Waterston 17...
Date:
By: SIR
1
Room name
Entire House
Laud
2
6posed wall
206.0 ft
9.0 ft
3
Room height
9.0 It
10.0 it heat/cool
4
Room dimensions
9.0 x 6.5 it
5
Room area
1769.3 ft2
58.5 ft2
Ty
Construclion
U-value
Or
HTNI
Area (ft2)
Load
Area (ft2)
Load
number
(Btuh/ft2-F)
(Btuh/ft2)
or perimeter (ft)
(Btuh),
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
-C
2A 2 �I e
0 330
n
5 83
9.67
4 Q6
990
400
16
377
�r 0
2196
156
1530
162
0
0
�3 30
�r0_
0
0
0
0
G
2A 2ov w
_ 0 330
9.57
8 52
b7,xnx
0
..- �_ 66
M.. w
0
w +0.
? 0Q
W
1613119ad
0.049
e
1.42
2.59
5
5
7
13
0
...
0
0
0
11
�Ikwallstu000ext
2A2ov
Q201
0330
a
r e ,
583
+ 957,2162
f
f 148
33
t ,
00A
4we
26 2fv
Q 330
r e i�
9 57
11 58
4
,
4
38
46
2B 2fv
A 330
e `
S 9 57
9.72
r 7
' 7
s 64
65
0
0
r. 0
0
" 0
0
0:
allJ0 u_
.. w0.600
e_
17.40.
_ 1Z5$
a 20_
".> .,.20
LL350L.a
353
s'0
W
16B-19ad
0.049
s
1.42
2.59
15
15
21
39
0
.0,-u
0
0
0
Blkwall stu000ezt ss
2A 2ov
0201
0 Wo
s
{ 583
957
406
516
10
and 483
s2816
1961
0
0
0
� 0
s
9 9Q
"
:
°�
10
93
97
0
0
0
0
2A 2ov
0.336
s
a 957
852
7
1' 7
66
58
0
0
0
0
_
:2A2ove`
0330
s
957
852
2_.
Blk wall, stucco e)d
_
0.201
w
5.83
,
4.06
308
224
1308
911
0
0
0
0
10C-m
0.550
w
15.95
12.64
18
18
285
226
0
0
0
0
2A-2ov
0.330
w
9.57
2629
49
3
469
1289
0
0
0
0
2A-2ov
0.330
w
9.57
9.90
17
17
161
166
0
0
0
0
12COsw
0091
264
137
294
27690'-
z 729
362
90
4 n
238
118`
a1D0
43
1.8
, A f8
,s €20.1
�203.,,
0
0
0:
C
166 30ad
0.032
0.93
1.69
1899
18-
1763
3209
59
w 59
54
99
F
22A tpl
0989
2& 68'
era 0:00
1769
206
_ 08
.,
59
�� 9258,
s 0
,r..u.
s....,...,v., .,.x. «.
,,, x.. a...........'
.i
k...................i,,;
.,�.e...._.n�
*
_'�*.
�.u<
....e.-._.�2.w»...
..3 a
.wy
w*......
+.k3z.
.di .u�.uu:du..
+�..auf«..w<.Wi'
.-w'n�+i..,.+iw.._✓1
»,.a..,:..�
_ +.
G...Y..,.._.
i.5w .aw. _
.......
.:.. ✓...
.F....w,_e...........»..�_.w.w.w'n'4e
..+a..u.+.._ .«....._
._.i:itd.
xniw.w
+s.mt.,,: ��
�.�u..
_=..u.'LY'..M.«.�$..s.
.,r.,v°ii,',u.
_.,...,..,._
s Y�
..•.v
`' " w
-F::.t.g.."v1
_l
,�.� .:..
�.�.._...<
�
�
�
,.=n,-.z
.r... tea... �
n.,.e.ev._ ..,. _
...-.._....,
r✓.w. _...". ,-k,
..«.«rm, u.3.��.
Ja+t �....�....w
.,,�.v+r:u.
i.Gy.:L3,,....
x,.ir,...»s.�
...,� ,<,wtio-�5..
.w�RFn.:..di::.�.
,
.,
-
_ '
_
lz;;,_
Z2=
ml=
M=°
�
w
6
c) AED excursion
1030
-35
Envelope loss/gain
17659
12968
550
182
12
a) Infiltration
3198
894
0
0
b) Room ventilation
0
01
0
0
13
Internal gains: Occupants pa 230
4
920
0
0
Applianceslother
2400
600
Subtotal (lines 6 to 13)
20857
17182
550
782
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
20857
17182
550
782
15
Duct loads
17 %
28%
3491
4843
17%
28 %
92
220
Total room load
24348
22025
642
1003
Air required (cf n)
947
947
25
43
Calculations approved bvACCAto meet all reaulrements of Manual J 8th Ed.
.�-*- =I i!R sott 2021-Jarf2614:3223
fi RighFSute®Universal 202121.0.02 RSU23828 Page 1
aterstone1720AGR\Lot18BIk1Waterstone1720AGR.nns p Calc=MJ8 Hoefaces: N
`-r - wrightsofr Right-M Worksheet
Entire House
DEL -AIR HEATING &AIR CONDITIONING
531 CODISCO WAY, SANFORD, FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web:WWW.DEL-AIR.COM
Job: Lot 18 Block 1 Waterston 17...
Date:
By. SIR
1
Room name
ktsir Bth
kktrwic
2
Exposed wall
26.0 it
0 it
3
Room height
8.5 it heaV000l
9.0 it heattcool
4
Room dimensions
1.0 x 141A it
1.0 x 61.9 it
5
Room area
141.4 ftz
61.9 ftz
Ty
Construction
U-value
Or
HTM
Area (it)
Load
Area (ftz)
Load
number
(Btuh/ftz-fl
(Btuh/ftz)
or perimeter (ft)
(Btuh)
or perimeter (it)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
'$Ik wall stucco ext
2A
0201
n r
5 83;
4 06
120
i13
659
459
0
0
. 0
�
0„
2ov
0330
n -
951'
990
0
; 0
0
0
0
0
, 0
0'
2A 2ou _
Q330
!l
..� 957
852
, . ,'7
.� 0
. � _ 66
: 0
x .,0,
Z
W
161319ad
0.049
e
1.42
259
0
0
0
.
0
0
_
0
0
x.
0
116lkwall
stu000ext
2A 2ov
0201
0.330
e�;
583'
406
0
0'
0
0
0
0`
0'
0
0
0
? 0
0
0'
2B 2N
0 330
e
9 5T
11 58
0
0
0
0
0
0
0
0
26 2fv r
0.330
a
9.5T
9:72
, E rf,A
r0
0
0
0
0
"
W
166-19ad
.0.600
0.049
s
1.42
2.59
0~
0
0
0
0
0
0
0
Blkwall stu000ext
2A2ov
0201
0;330
`ems
, s
5a
957,
4.06
9.90
; 0
° 0
0
{ * k 0
z 0
0�
0
�0
0
0
0
= �0
- 0
0
0`
0
y
2A2ov
0330
s`
967
8.52
000'
2A2ov($30
�_s
957:
w. 0
K w0
�0
Blk wall, stucco e)d
0201
w
5.83
4.06
0
0
0
�� `0
. -
0
0
0
0
10C-m
0.550
w
15.95
12.64
0
0
0
0
0
0
0
0
2A-2ov
0,330
w
9.57
2629
0
0
0
0
0
0
0
0
2A-2ov
0,330
w
9.57
'9.90
0
0
0
0
0
0
0
0
R
12C Osw
Q;091
2 64,'
13 L
88
t 88
232
115
0
0
0
0'
L.—p.
1:1DO K
Q;390
__n.w
.m 1131.
.. Jt 43
H.0
.ram0
r 0
Y
. r 0
0
C
1613-30ad
0.032
0.93
1 69
148
148
138
250
69
69
64
116
_w
-
,
ifM ._
_
_ ._
,H.
n, �r..
-u
.'m ,'
_..-...
_..a�...v...�..-_...�....�aa.-..x
u......,��
_
„m..a..M
4
Ys
7
.....-...,
.K'....v..vyiw4.u..-....w..v.
.,..r�.s,_.w......--•A
_.sra2.�:
_ h.,..vm
...✓... �
...e.+o- <.d`z w...'w
�,. o.� �
.v..C.�.sm._v1
�"....a ..w...
.®..P .:.....r.d+�.
_...tom "'
+u.a...�.
.ir:�, +:.,,.�w�
,..,--.,3i
x >.w��-..vvw.,,�.._w..a...,..
.....,tr..,...-,,�.n_�
��.��5 �m'
w:..L kw,.,.vawE
....`....,..,..✓..... „�,
S.«.,.,,. "�
- �,.k
��"�.z
s....w,r ...z
u..c
.... C.
`.c.-a, _.,....
*
t
..?
=.Lz.........W.,.........t.�+..,_'
...�. _ .,
.....
�...-.n.z.ak,.
r....-� .L....*
.,.... .,...`.k
wcm.,eT9v..=
...,....... 1w
..x..x.
r
_2
.....¢...�.....'GR
:.... -....-
.vA.....am._
-.w.a=
...w ..etMEM
5..0 r.
cr '
.. .;
.y..'.. `�.y'..'
'9 1"F�.v:..,.:.}.
�Y'^"....:
�.w>..«w...:;:
uw.0 v..4.n "k'
»w.cwT 1G✓�
..�u.....-... v'5"u^
i.�».v.. ,.=...r
a,v,. -.d.�
� �Y w, �
t�i YF,; .La��qq
w"�. .�„
.v.... E........
.....,.....».,.20',..xa
s. t;.._az....,
.�..3
rcravx. ..w.
k la.. ....:v
..,,.3-..
mow.,,..«.
u„-... tn...
..,.. ....rv..
..w.._'.."
.,,�...s.,x,i
6
c) AED exalrsion
-41
-5
Envelope loss/gain
1841
. 843
64
111
12
a) Infiltration
276
77
0
0
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants@ 230
0
0
0
0
Applianceslother
0
0
Subtotal (lines 6 to 13)
2116
920
64
111
Less extemalload
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
2116
920
64
111
15
Duct loads
17%
28%,
354
259
17 %
28 %
11
31
Total room load
2471
1179
74
142
Air required (cfm)
96
51
3
6
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
-rk- wrGgr+tsoTt• 2021-JarF2614:3233
A& a Right-Sute®Universal 2021 21.0.02 RSU23828 Page 2
aterstore1720AGR\Lot18BIk1Waterstore1720AGR.np Calc=MJ8 Hoisefaces: N
wrightsofta Right-M Worksheet
Entire House
DEL -AIR HEATING & AIR CONDITIONING
531 CODISCO WAY, SANFORD, FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web: W W W.DEL-AIR.COM
Job: Lot 18 Block 1 Waterston 17...
Date:
By: SIR
1
Room name
Wr Bdrm
Livrm
2
Exposed `mall
34.5 ft
78.5 ft
3
Room height
9.1 ft heaV000l
9.0 ft heaVcool
4
Room dimensions
15.5 x 15.0 ft
1.0 x 841.8 ft
5
Room area
294.5 ftz
841.8 ftz
Ty
Or
HTM
Area (ftz)
Load
Area (ft2)
Load
number�on
BU�aue
( `)
(Btuh/ft2)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
��l
Blk wall stumo eM
$0 201
`0330
n `
5 n
5.83
957
,4.06
9.90
' s 152
s �i6
.136
0
791
156
551
40
;, + x 40
233162
�-('
2A
162
r 0
0
0
;d0
2ov •
0330
,.a!?
w. 957
__ 85?
_.' �„ 4
ti_ >,
W
166 19ad
0.049
a
1.42
2.59
0
0
0
0
5
5
_,
7
13
11
a'?Blkwall
stuaoext
�2A2ou "�
0201
9330
a
a
5.83
406
�1.6�
' 0
0
0
' 0
0
�0
0
0
52
0
21'
�� � 0
124
e0
-86
26 2(v
0330
e -
w9.57
9.57
11 58
0
0
0
p
4
;=,Oi
262N
0330
e,'
9.57
972
,
0
0
" 0
0
4
1 7:'
7
38
46
p600
a
17.40
_�17.58
� ''0
, r > 0
a� 0
Ww.O
»20
° 20.
56
,_ '353,
W
1613-19ad
0.049
s
1 A2
2.59
0
0
0
0
15
15
w_.
21
_
39
Blk wall stucco ext
2A 2ov
0201
0330
s
s'•
5.83
9.57
406
990
0
0
` 0
0
0
0
0�
0
236
10
- 226
10
1319
' 93
919
97!
PA
f957„
.57
2A2ov_n�_,
8.52
Blk wall, stucco ext
10C-m
0.201
0550
w -
w
5.83
15.95
4.06
12.64
124
0
91
0
532
0
371
0
184
18
133
18
775
285
540
226
2A-2ov
0.330
w
9.57
2629
33
2
313
859
16
1
156
430
2A-2ov
0.330
w
9.57
9.90
0
0
0
0
.17
17
161
166
0091
264
1.3
0
0
0
0
716
' 98
r259
129;
,].
11.43
, o
, a v .x0
. 5. 01
�L,.. Q
,� 18
'LL. 78
.� ],...;..201
C
16B-30ad
0.032
0.93
1.69
329
329
306
556
906
,
906
841
_..., ,203
1530
¢=...295
1w.-u35
L 98.9,
D,
842.>a�
2251
7 0;
>
a
79._
r
ew
---.•--c
ter;
r-*'�,
EL
x
Z._a=
>
Z_'3Z ,, x- a_
_ a.
f=
M=
=
...tea..,., w
_
�,... .,.,...
.... � ,.2>.
�...b>..w,
....>v...�,..,3:i-
,.....�,w..,...
-
-
�«,.w
.,._.
....,...s..us.-.«a...�l.,...m...=
,.s,
xa..,.,.....:4....i
.vF_o,,..3
.,.->1�......,
-� .n
.._...emu•
r
.. ,.z,
R�
2
_
a
m
....,.._
s_....r�..,.+,�"W,.....,..
_s �A..,....-
A.s,.,w�..
,.._..v,.,,.e:
Tl
..a ,._......�.
._..,w.>s,..
w
>,,.2.r.a..�
'i+a.,...,..:..-.>+�.-.._.«.w.,'_'......
.ws».....k.........-....
....,...:dl
_mw..e....w.�:.w
.ay..v.....�.,�.:
«. .�xi...w,.=:A,...>
.... -....
,.,.i...:...,.....�_
..._w..>..._.....,L,
.�->,..-r..r...w .«
>::,.
.,..aa=
:2.,. ..>r...
.s-
7.. k-,....
w.a,..-,�,�..'�"'..,..
,..,
.�..._
..�.�,.......�_.-.._�:s�.,
.>....-..._.
...-_
.�..,...x.:..
�.,._.a_s.
.,,.,.,..G...c^.`n->..1,.....ih..
.,w. u�t..s„
v_,.:,,.-.,�
_.,....._...._..�_
.-....«.-.... uZ,
�.,..,s..,...
......e.
�
.w...aay..o-�.v�..
..
_.-..L_
r..,.....`«
Y ., F
,t•;
jR
`4
v*d ..:...«.......
excursion
.-irI'J''P
.u4..«v".
231
6
c) AED
796
Envelope loss/gain
3087
2730
7179
5800
12
a) Infiltration
634
177
1222
342
b) Roomventilation
0
0
0
0
13
Internal gains: Occupants@ 230
1
230
3
690
Appliances/other
600
1200
Subtotal (lines 6 to 13)
3721
3738
8401
W32
Lessexlemalload
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
3721
3738
8401
8032
15
Dud loads
17 %
28%
623
1054
17 %
28 %
1406
2264
Total room load
4344
4791
9807
10296
Air required (cfm)
169
206
381
443
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
A%-rk- wrigtitsoTC ° 2021-Jan-26143233
K Right-Sute®Unversal 2021 21.0.02 RSU23828 Page 3
aterstone1720AGR1Lot18Blk1Waterstone1720AGR.rup Caic=MJ8 House faces: N
-- wrightsoft Right-JO Worksheet
Entire House
DEL -AIR HEATING &AIR CONDITIONING
531 CODISCO WAY, SANFORD, FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web:WWW.DEL-AIR.COM
Job: Lot 18 Block 1 Waterston 17...
Date:
By: SIR
1
Room name
Bdrm 3
Bth 2
2
Exposed wall
36.5 It
8.0 ft
3
Room height
8.0 It heaVcool
8.8 ft heattcool
4
Room dimensions
1.0 x 152.0 it
8.0 x 8.0 It
5
Room area
152.0 112
64.0 112
Ty
Construction
U-value
Or
HTM
Area (ftz)
Load
Area (It)
Load
number
(Btuh/ft2-'F)
(Btuh/ft2)
or perimeter ft ()
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
$Ik wall stucco ext
2A 2ov
0201
0330
n `
n
5 83
* 957
4 06
9.9b
88
¢ 0
88
513
*
357
0
`
t "" 0
$p
-'d
2A 2ov } :,
._ k 0330
ti P _
957
852
.
vQi0
0
0
. f .a �0w0
0
3 r 0
W
166 19ad
0.049
e
1.42
2.59
0
0
0
0
0
0
0
0
11
�Blk wall'slucoo ext
2A 2ov
2B 2N71 a
0.201
0 330
0330
a r`
' e s
5 83
'9.57
`'4 06
r 21 62
33
63
% 0
369
313
257
707
0
x0
Q
= 0
0p.
0
0
a
.1158
2B 2N
0 330
a ,,
9.57
972
0
m^ 0
✓ 0
0'
31J0_w
0600
, =e�
_ i7AU
1 758
W
168-19ad
0049
s
142
2.59
0
0
0
0
0
0
0
0
$Ikwallstucooext
2A 2ov
Q201'
0336
s`
s
583
9.57
406108108
9.90
0
0
630
0
439
0
64
0
57,
0
p 333
6,
232'
0
2A2ov
0330
s
957
852
0
0�0
0
7
7
ti6
58
.2A 2oY 1
__ Q 330
s
9.57
8`.52
_. 0
«
. >w.;_ 9
x'
Blk vVall, stucco ext
0.201
w
5.83
4.06
0
0
0
0
0
0
0
0
10C-m
0.550
w
15.95
12.64
0
0
0
0
0
0
0
0
2A-2ov
0.330
w
9.57
2629
0
0
0
0
0
0
0
0
2A 2ov
0 330
w
9.57
9.90
0
0
0
0
0
0
0
0
72COsw'a
0091
�7. ;-
264
131�
, 0
s00�
�� 0
00;
0
r �'0�
a
_11D0
cy
C
16B 30ad0
032
0.93
1.69
152
152
141
257
68
.a�0
68
63
114
f-u
Br
"t
�'x`
��{
�
t
6
@'
t 6
P^"`
Y
� �
w.
_r x._'''
✓"""Yt
,.sw..r.✓
.,...
�.. _...v.,.a.„�,._s vn.......c�...
�i...._x.s.i
us.�.«d...� -
.-�..a.mbd
....xw u_.-.ec
._....,.,., �.vsi
w...b.:.i «a.l..
o.=.
... uL2
712
......
=
Z2=
.so..._ ..�...._..._...w,..�..�.'*'a
_ ,........
........s
.E....s.,. v
......
'c....ww11=
av,s.3
u.w+...
"
.».+.w�..sti.a.._..._+�..+,.s.:.
_.................
.x.&..,._
_.3..�x,c
__....»._.w-
..r.d _
_....�...,..
kr 1
nw ..,.z
..,�
w_.a...s......,..t..w �..v... t.uE
..�............"..i.�.m
.r
w..
_.�.....:
t 1s3...,.�`.
...rw.X✓,:7..�t
'Ls{
w
��
.....¢,.,.��r..__._. _
.....c.2x.c..
�fl,.#,�.
.m........
...�... „s
✓. -w
^Y#u r'X�
...«.�2m�.....+.
_... _ �
,i_�vu,.
..
,.
..._.-_v,d,..._..x...._..,.v -
w...uws,c»�.
a..
..._.......-b:.
.,._.,...v
.».w.+-.,:...
a.+.wsn$
e
-e
6
c) AED
excursion
139
-19
Envelope loss/gain
3012
2155
691
386
12
a) Infiltration
671
187
147
41
b) Roomventilation
0
0
0
0
13
Internal gains: Occupants@ 230
0
0
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
3683
2343
838
427
Less e)demal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
3683
2343
838
427
15
Ductloads
179/6
28%1
616
660
179/6
28%1
140
120
Total room load
4300
3003
978
547
Air required (cfm)
167
129
38
24
Calculations approved byACCAto meet all requirements of Manual J 8th Ed
A&-*- wrigF�tsoR^ 2021-Jan-2614:3233
K Rigid-Sdte®Uriversal 2021 21.0.02 RSU23828 Page 4
aterstone1720AGR\Lot18BlklWaterstone1720AGR.np Calc=MJ8 Hoisefaws: N
- - wrightsoft, Right-M Worksheet
Entire House
DEL -AIR HEATING & AIR CONDITIONING
531 CODISCO WAY, SANFORD, FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web: W W W.DEL-AIR.COM
Job: Lot 18 Block 1 Waterston 17...
Date:
By: SIR
1
Room name.
Bdrm 2
2
Exposed wall
13.5 ft
3
Room height
9.3 ft heaVcool
4
Room dimensions
11.5 x 13.5 ft
5
Room area
1552 ftz
Ty
Construction
U-value
Or
HTM
Area (ftz)
Load
Area
Load
number
(BtuWF)
(Btuh/ftz)
or perimeter (ft)
(Btuh)
or perimeter
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
Blk wall stucco ext
2A 2ov `,
D 201
0.330
n
n ':
5 83
9 57
# 406
990
" 0
0
07.00
0
W
16B 19ad
0049
a
142
259
0
0
0
0
11
;BM%dl stuaooext
2A 2ov
0201
0.330
e'--
a
583
957
7406'
162
i ; 0
0
` 0
0
0
f 0
'
s
26 2fv
=,0.330
:`e '
0957
11.56
R`
t 0
0
'
2B2fv
0330
,
972
0
0
0
�0
0
0
b'
w
W
1613•19ad
0.049
s
1.42
2.59
-D
0
0
0
0
131k,wall stii000 ext
2A 2ov
0 201
0330
s
s
5 83
957
4 05
+ 990
108
O
—i92
F 0
" ,
0
" 372
0
� '"'
2A2ov
0.330
s'
9 b7
8 52
r 0
0
2A20V
0330
3 s.
957.__
8.52;�.�....;-;�,,:16
Blk wall, stuao ext
0.201
w
5.83
4.06
0
0
0
0
1007m
0.550
w
15.95
12.64
0
0
0
0
2A-2ov
0.330
w
9.57
2629
0
0
0
0
2A-2ov
0.330
w
9.57
9.90
0
0
0
0
12C Osw
5 ,'0 091
2 64
1.31
M6
.;.11DO...�.�.�...u..�.k�..A
�
u•
C
166-30ad
0.032
0.93
1.69
170
170
157
287
F
22A1p1
;"9989
28.68
=Da
� -'. 1_4
mum
�s 0
_ _.a
,
� a.0A0
y
az
R.,
e.+s�_....._....u...�....b.....,..
dui'^.,
u
z! M..m...n.
>h...d...
,e�.sa.
�..::G.a s..,',...
.'..�..�...,.,....;
..............s
s.a.-.....»...;.`;_
..--P-k.'F::..,ru`
+`
„
,..
v.xG..,_...«...,✓..him.
....ua......
{.z'..
.......
,�....dG:,_...
a....,+«.n..�
v....v.�ii::,....�.
:r ..-.w.. .......>,:.i
.n.
,...v,s.»..
e .u...�i...,,
....�....-j :+U.....t�...n..,.
�''.._.a...0
.:,.St-�
_...-.:l.,t
.h-a ....
>., _
.S. «..�,.,d
..< C...a.; �✓.w
�
�,e.w'�•
.....y...,...«
=w,._.w>.E.F'
.-....e...4..W",.:.2
2..=«.o...s.�e.
.s..,.»,ti...a
_
"'....'� � "'".
�
'.�'.;
.?'�44
�e
�-ts
wee
`3" 5
: -+ � w
=N'"'"� �,3
�^ •r` .
��
w._
.,_„v.,........
......,a.�-x.
w. _
.».,5.ew.,..:.
.�..,.-.»._.,„
,..w.i.r.„.;�'�.�.,.m
a�--:::�.xi�.x
''
a3.u�
�.......,...
"a��..,.��
,....
.; ..�a�........-.____.-
...,��.,.....
...._...,.-.a:�.
w.�.....i.��
.-,_._»...
.N_. .emu
..� ..t.,_
_7.
M7,_717CE
1— :-
-,
-37
6
c) AED
excursion
Envelope loss/gain
1235
761
12
a) Infiltration
248
89
b) Room ventilation
0
0
13
Internal gains: Occupants@ 230
0
0
Applianceslother
p
Subtotal (lines 6 to 13)
1483
831
Less external load
0
0
Lesstransfer
0
0
Redistribution
0
0
14
Subtotal
1483
831.
15
Ductloads
17%
28%1
248
234
Total room load
1732
1065
Air required (cfm)
67
48
Calculations approved byACCAto meet all requirements of Manual J 8th Ed
wrigF�tsotFt .�CGA Rigl�-Sute®Uriversal 2021 21.0.02 RSU23828 2021-Jan-2614:3203 Page 5
aterstone1720AGR\Lot18BIk1Waterstone1720AGR.rLp Calc=MJ8 Hoisefaces: N
y nstem wrightsoft® Duct S Summary Job: Lot 18 Block 1 Watersto...
Date:
Entire House By: SIR
DEL -AIR HEATING & AIR CONDITIONING
531 CODISCO WAY, SANFORD, FL 32771 Phore:407-333-2665 Fax:407-333-3853 Web:WWW.DEL-AIR.COM
Froject intormation,
For: ADAMS HOMES
5380 Lugo Street, Fort Pierce, FL 34951
External static pressure
Pressurelosses
Available static pressure
Supply/return available pressure
Lowest fri cti on rate
Actual airflow
Total effective length (TEL)
Heating
0.40
in H2O
0.06
in H2O
0.34
in H2O
0.170 / 0.170
in H2O
0.284
in/100ft
947
cfm
120
SupplyBranch Detail Table
Cooling
0.40 in H2O
0.06 in H2O
0.34 in H2O
0.170/0.170 in H2O
0.284 in/100ft
947 cfm
Name
Design
(Btuh)
Htg
(cfm)
Clg
(cfm)
Design
FR
Diam
(in)
H x W
(in)
Duct
Mat
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
Bdrm2
h 1732
67
46
0.329
6.0
Ox0
VIFx
18.4
85.0
sti
Bdrm3
h 4300
167
129
0.284
7.0
Ox0
VIFx
34.6
85.0
st1
Bth 2
h 978
38
24
0.309
4.0
Ox 0
VI Fx
25.0
85.0
st1
Laud
c 1003
25
43
0.462
4.0
Ox 0
VI Fx
3.5
70.0
Livrm
c 2574
95
111
0.422
6.0
Ox 0
VIFx
10.6
70.0
Livrm-A
c 2574
95
111
0.400
6.0
Ox 0
VI Fx
15.0
70.0
Livrm-B
c 2574
95
111
0.374
6.0
Ox 0
VI Fx
21.0
70.0
Livrm-C
c 2574
95
111
0.352
6.0
Ox 0
VI Fx
26.6
70.0
Mstr Bdrm
c 4791
169
206
0.371
8.0
Ox 0
VIFx
21.7
70.0
Mstr Bth
h 2471
96
51
0.411
6.0
Ox 0
VI Fx
12.7
70.0
Mstr ""c
c 142
3
6
0.435
4.0
Ox 0
VI Fx
8.2
70.0
Supply Trunk Detail Table
Name
Trunk
Type
Htg
(cfm)
Clg
(cfm)
Design
FR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Duct
Material
Trunk
st1
PeakAVF
273
198
0.284
500
10.0
0 x 0
VinlFlx
,` * wrightsoft,
1- .-,Ber1 1.1-xo,fomp Rigfd-SuteOUriversal202121.0.02RSU23828
ICCK aterstone1720AGRtLotl8BIklWaterstore1720AGR.rLp CaIc=MJ8 Hoisefaces: N
2021-Jarr2614:3213
Page 1
Return Branch Detail Table
Name
Grille
Size (in)
Htg
(Cfm)
Clg
(cfm)
TEL
(ft)
Design
FIR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Mat
Trunk
rbi
Ox 0
947
947
0
0
0
0
Ox 0
VIFx
- wrightsoft-
���M,,.t•,�..�h..bw...,�m„., Right-Srite@Uriversal2021 21.0.02 RSU23828
aterstone1720AGR\Lot18BIk1Waterstone1720AGR.rr{r Calc=MJ8 Horse faces: N
2021-Jarf2614:3233
Page 2
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Lot 18 Block 1 Waterstone 1720 AGR Builder Name: ADAMS HOMES
Street: 5380 Lugo Street Permit Office:
City, State, Zip: Fort Pierce , FL , 34951 Permit Number:
Y
Owner: Jurisdiction: 661000
w
Design Location: FL, ST_LUCIE_CO_INTL
v
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in an dropped soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
as.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the finished surface.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind pophria and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub -floor, wall covering or
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover plates and walls or ceilings.
a. In addition, inspection or log walls shall be in accordance with the provisions of ICC-400.
1/26/2021 2:39 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1
FORM R405-2020
RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST
Florida Department of Business and Professional Regulation
Simulated Performance Alternative (Performance) Method
Applications for compliance with the 2020 Florida Building Code, Energy Conservation via the
Residential Simulated Performance Alternative shall include:
❑ This checklist
❑ Form R405-2020 report
❑ Input summary checklist that can be used for field verification (usually four pages/may be greater)
❑ Energy Performance Level (EPL) Display Card (one page)
❑ HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7
❑ Mandatory Requirements (five pages)
Required prior to CO:
❑ Air Barrier and Insulation Inspection Component Criteria checklist (Table R402.4.1.1 - one page)
❑ A completed 2020 Envelope Leakage Test Report (usually one page); exception in R402.4
allows dwelling units of R-2 Occupancies and multiple attached single family dwellings to
comply with Section C402.5
❑ If Form R405 duct leakage type indicates anything other than "default leakage" then a completed
2020 Duct Leakage Test Report - Performance Method (usually one page)
1/26/2021 2:38:38 PM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1
Duct Leakage Test Report
Residential Prescriptive, Performance or ERI Method Compliance
2020 Florida Building Code, Energy Conservation, 7th Edition
Jurisdiction: 661000 Permit #:
Job.lnformation
Builder: ADAMS HOMES Community: Lot: 18
Address: 5380 Lugo Street
City: Fort Pierce State: FL Zip: 34951
Duct. Leakage Test Results. -
System 1
cfm25
System 2
cfm25
System 3
cfm25
Sum of others
cfm25
Total of all
cfm25
— 1720 = Qn
Total of all
Total Conditioned
systems
Square Footage
PASS [:]FAI L
Q Prescriptive Method;, cfm25 (Total)
To.qualify'as'substartbally,Eleak free""Qn.,Total must"be"'less than or'G
equal to 0.04 if air handler. unit isF nstailed If air handlbr unit is •not. _
Installed"'On• Total "must be less" .ti amor equal•to `0a03: This testing'
me'thod:,meets-'the requirementsin accordance with Section R403 33:
1s the air handler unrf instaged during testing? DrYES (5'0)' NO�`(S;o
Q Pe�rformanee/ERI Method- cfm25 (Out or'Total)
To qualify using this method, Qri must not be,greater•tfan the .
prop"osed duct;leakage"Qn specified on Form R405-2020 or',R406-2020
Leakage Type;selected o`n".Form Qn.specifiec on Form R405 2020.
R405-2020 (En ergyCalc), or R406.2020 (EnergyGa/c) or A406:2020t .
Proposed Qn 0.06
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either individuals as defined in Section
553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes.
Testing Company,
Company Name: Phone:
I hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the
selected compliance path as stated above, either the Prescriptive Method or Performance Method.
Signature of Tester: Date of Test:
Printed Name of Tester:
License/Certification #:
Issuing Authority:
1/26/2021 2:39:48 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1
Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2020 Florida Building Code, Energy Conservation, 7th Edition
Jurisdiction: 661000
Permit #:
Job Information. s
Builder: ADAMS HOMES Community: Lot: 18
Address: 5380 Lugo Street
City: Fort Pierce State: FL Zip: 34951
Air Leakage Test.;ResultS `Passing"results•must meet erther'`the Performance; Prescnptive; or.ER!•`IVlethoci
., h..
PRESCRIPTIVE METHOD=The building,or dwelling unit shall be=tested and verified as having an air.leakage rate•'of not exceeding"7 air "
changes per hour at,a pressure of 0.2'inch w:g '(50 Pascals) in Climate Zones 1 and,2.
Q PERFORMANCE `or ERI METHOD=The'building or dwelling unif shall be'tesled an, verified as, having an air Ie_akage rate of ndt�exceedin'
the selected ACH(50);value, as shown on form R405-2020 -.(Performance) or R406-2020 (ERI), section labeled as infiltration, sub -section ACH50.
ACH(50) specified omForm R405-2020-EnergyGatc (Performance) or, R406>2020 (ERI): 7.000
x 60 _ 15480 = Method for calculating building volume:
CFM(50) Building Volume ACH(50)
Q Retrieved from architectural plans
1-1 PASS
• Code software calculated
When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated
must be verified by building department.
R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals)
Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section
489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration
control measures.
2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control
measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
Testing Company
Company Name: Phone:
I hereby verify that the above Air Leakage results are in accordance with the 2020 7th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
Signature of Tester: Date of Test:
Printed Name of Tester:
License/Certification #: Issuing Authority:
1/26/2021 2:39:35 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1
Florida Building Code, Energy Conservation, 7th Edition (2020)
Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods
ADDRESS: 5380 Lugo Street Permit Number:
Fort Pierce , FL , 34951
MANDATORY REQUIREMENTS - See individual code sections for full details.
SECTION R401 GENERAL
R401.3 Energy Performance Level (EPL) display card (Mandatory) The building official shall require that an energy performance level (EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law
❑ (Section 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD.
SECTION R402 BUILDING THERMAL ENVELOPE
❑ R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.4.1 through R402.4.5.
Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to
comply with Section C402.5.
❑ R402.4.1 Building thermal envelopeThe building thermal envelope shall comply with Sections R402.4.1.1 and
R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction.
❑ R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance
with the manufacturer's instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required
by the code official, an approved third party shall inspect all components and verify compliance.
❑ R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air
changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in
accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either
individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i) or
an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing
buildings in which the new construction is less than 85 percent of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or
other infiltration control measures.
2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended
infiltration control measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
❑ R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where
using tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the
fireplace. Where using tight -fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907.
❑ R402.4.3 Fenestration air leakage. Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm
per square foot (1.5 L/s/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 L/s/m2), when tested according to NFRC 400 or
AAMA/ WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer.
Exception: Site -built windows, skylights and doors.
1/26/2021 2:39 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5
MANDATORY REQUIREMENTS - (Continued)
R402.4.4 Rooms containing fuel -burning appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to
open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or
enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements
of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be
fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it
passes through conditioned space to a minimum of R-8.
Exceptions:
1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside.
2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential.
R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not
more than 2.0 cfm (0.944 Us) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
R403.1 Controls. SECTION R403 SYSTEMS
R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls
that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load.
R403.3.2 Sealing (Mandatory) All ducts, 'air handlers, filter boxes and building cavities that form the primary air containment passageways
for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section
C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below.
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or
(7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes, to be "substantially leak free" in
accordance with Section R403.3.3.
R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent
of the design airflow rate when tested in accordance with ASHRAE 193.
R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods:
Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system,
including the manufacturer's air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise
sealed during the test.
Postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the entire
system, including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the test.
Exceptions:
1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building
thermal envelope.
2. Duct testing is not mandatory for buildings complying by Section 405 of this code. Duct leakage testing is required for Section
R405 compliance where credit is taken for leakage, and a duct air leakage Qn to the outside of less than 0.080 (where Qn =
duct leakage to the outside in cfm per 100 square feet of conditioned floor area tested at 25 Pascals) is indicated in the
compliance report for the proposed design.
A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.
R403.3.5 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums.
❑ R403.4 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41°C)
or below 55°F (13°C) shall be insulated to a minimum of R-3.
R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that
caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause
degradation of the material. Adhesive tape shall not be permitted.
R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory). If heated water circulation systems are
installed, they shall be in accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with
Section R403.5.1.2. Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible.
❑ R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe shall
be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited. Controls for
circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy. The
controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no
demand for hot water.
R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall
automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the
times when heated water is used in the occupancy.
1/26/2021 2:39 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 5
MANDATORY REQUIREMENTS - (Continued)
R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3 % inches (89 mm) in the hot water distribution line and cold water line located as close as possible
to the storage tank.
R403.5.6 Water heater efficiencies (Mandatory).
❑ R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable
of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature
setting range shall be from 100°F to 140°F (38°C to 60°C).
❑ R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to
electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of
combustion types of service water -heating systems to be turned off.
❑ R403.5.6.2 Water -heating equipment. Water -heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate
water -heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1.
R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors,
and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar
water -heating systems should meet the following criteria:
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and
2. Be installed at an orientation within 45 degrees of true south.
❑ R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation
including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that
close when the ventilation system is not operating.
❑ R403.6.1 Whole -house mechanical ventilation system fan efficacy.When installed to function as a whole -house mechanical
ventilation system, fans shall meet the efficacy requirements of Table R403.6.1.
Exception: Where an air handler that is integral to tested and listed HVAC equipment is used to provide whole -house mechanical
ventilation, the air handler shall be powered by an electronically commutated motor.
❑ R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation
shall meet the following criteria:
1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable
Indoor Air Quality, shall be the maximum rates allowed for residential applications.
2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics,
crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas.
3. If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be
insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19, space permitting, or R-10
otherwise.
R403.7 Heating and cooling equipment.
R403.7.1 Equipment sizing (Mandatory). Heating and cooling equipment shall be sized in accordance with ACCA Manual S based
❑ on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation
methodologies, based on building loads for the directional orientation of the building. The manufacturer and model number of the
outdoor and indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design
conditions described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other
factors that affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical
ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have
an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is
installed.
TABLE R403.6.1
WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY
FAN LOCATION
AIRFLOW RATE MINIMUM
(CFM)
MINIMUM EFFICACY a
(CFM/WATT)
AIRFLOW RATE MAXIMU
(CFM)
HRV or ERV
Any
1.2 cfm/watt
Any
Range hoods
Any
2.8 cfm/watt
Any
In -line fan
Any
2.8 cfm/watt
Any
Bathroom, utility room
10
1.4 cfm/watt
<90
Bathroom, utility room
90
2.8 cfm/watt
Any
For SI: 1 cfm = 28.3 L/min. a. When tested in accordance with HVI Standard 916
1/26/2021 2:39 PM EnergyGauge® USA 7.0.00 - F]aRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5
MANDATORY REQUIREMENTS - (Continued)
❑ R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less
than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section R403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's
expanded performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb
temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded
performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature.
Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space.
Exceptions:
1. Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is less than the
2. calculated total sensible load but not less than 80 percent of that load.
When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of
equipment may be sized in accordance with good design practice.
R403.7.1.2 Heating equipment capacity.
❑ R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section
R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if
the design heating load is 1.15 times greater than the design cooling load.
❑ R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.7.1.
❑ R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.7.1.
❑ R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
❑ R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections
C403 and C404 of the Florida Building Code, Energy Conservation —Commercial Provisions in lieu of Section R403.
❑ R403.9 Snow melt and ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building,
shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F (10°C), and no
precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F (4.8°C).
❑ R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas
shall be in accordance with Sections R403.10.1 through R403.10.5.
❑ R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an
integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation
of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the
power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots.
❑ R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule
shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this
section.
Exceptions:
1. Where public health standards require 24-hour pump operation.
2. Pumps that operate solar- and waste -heat -recovery pool heating systems.
3. Where pumps are powered exclusively from on -site renewable generation.
1/26/2021 2:39 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5
QR403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at
the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered
energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required.
R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal
❑
efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool
heaters fired by natural or LP gas shall not have continuously burning pilot lights.
R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is
required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard.
R403.11 Portable spas (Mandatory).The energy consumption of electric -powered portable spas shall be controlled by the
requirements of APSP-14.
R403.13 Dehumidifiers (Mandatory If installed, a dehumidifier shall conform to the following requirements:
1. The minimum rated efficiency of the dehumidifier shall be greater than 1.7 liters/ kWh if the total dehumidifier capacity for the house
is less than 75 pints/day and greater than 2.38 liters/kWh if the total dehumidifier capacity for the house is greater than or equal to 75 pints/day.
2. The dehumidifier shall be controlled by a sensor that is installed in a location where it is exposed to mixed house air.
3. Any dehumidifier unit located in unconditioned space that treats air from conditioned space shall be insulated to a minimum of R-2.
4. Condensate disposal shall be in accordance with Section M1411.3.1 of the Florida Building Code, Residential.
�. R403.13.1 Ducted dehumidifiers. Ducted dehumidifiers shall, in addition to conforming to the requirements of Section R403.13,
conform to the following requirements:
1. If a ducted dehumidifier is configured with return and supply ducts both connected into the supply side of the cooling system, a backdraft
damper shall be installed in the supply air duct between the dehumidifier inlet and outlet duct.
2. If a ducted dehumidifier is configured with only its supply duct connected into the supply side of the central heating and cooling system,
a backdraft damper shall be installed in the dehumidifier supply duct between the dehumidifier and central supply duct.
3. A ducted dehumidifier shall not be ducted to or from a central ducted cooling system on the return duct side upstream from the
central cooling evaporator coil.
4. Ductwork associated with a dehumidifier located in unconditioned space shall be insulated to a minimum of R-6.
SECTION R404
ELECTRICAL POWER AND LIGHTING SYSTEMS
R404.1 Lighting equipment (Mandatory). Not less than 90 percent of the lamps in permanently installed luminaires shall have an
efficacy of at least 45 lumens -per -watt or shall utilize lamps with an efficacy of not less than 65 lumens -per -watt.
R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights.
1/26/2021 2:39 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 5