Loading...
HomeMy WebLinkAboutProject InformationManual S Compliance Report Jab: Lot23 Block 1 Waterston ... -�- wrightsoft® Date: Entire House By: Dcs DEL AIR HTG, A/C & REFRIG. INC 531 CODISCO WAY SANFORD, FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web: W W W.DELAIR.COM M ADAMS HOMES 5360 Lugo Street, Fort Pierce, FL 34951 Design Conditions Outdoor design DB: 90.4 cF Sensible gain: 26392 Btuh Entering coil DB: 76.4°F Outdoor design WB: 77.4°F Latentgain: 4767 Btuh Entering coil WB: 63.2OF Indoor design DB: 75.0 cF Total gain: 31159 Btuh Indoor RH: 50% Estimated airflow: 1167 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Carrier Model: 25HBC537AP03+FX4DNB037L00 Actual airflow: 1167 cfm Sensible capacity: 28095 Btuh 106%of load Latent capacity: 5190 Btuh 109%of load Total capacity: 33285 Btuh 107%of load SHR: 84% Heating Equipment Design Conditions Outdoor design DB: 41.0 cF Heat loss: 28571 Btuh Entering coil DB: 69.5°F Indoor design DB: 70.0 OF Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Carrier Model: 25HBC537AP03+FX4DNB037L00 Actual airflow: 1167 cfm Output capacity: 32782 Btuh 115% of load Supplemental heat required: 0 Btuh Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1167 cfm Output capacity: 7.6 kW 91 % of load Temp. rise: 20 OF Meets all requirements ofACCA Manual S. Capacity balance: 36 OF Economic balance: -99 OF Q * wrightsoft, 2021-Jar0214:51:14 �� �M,.. �......vb...�m Right-Sute®Uriversal2021 21.0.02 RSU23828 Page 1 aterstonel820AGR\Lot23BIklWaterstoml82OAGR.rLp Calc=MJB FrontDoorfaces: E Com onent Constructions Job: Lot23 Block 1 Waterston... - wrightsoft® p Date: Entire House By: DCs DEL AIR HTG, A/C & REFRIG. INC 531 CODISCO WAY, SANFORD, FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web: W W W.DELAIR.COM niflaept intormation For: ADAMS HOMES 5360 Lugo Street, Fort Pierce, FL 34951 Design Condition's Location: Indoor: Heating Cooling St Lucie Co Intl, FL, US Indoor temperature (OF) 70 75 Elevation: 26 ft Design TD (OF) 29 15 Latitude: 28 °N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (grab) 2.4 56.9 Dry bulb (OF) 41 90 Infiltration: Daily range (T) - 15 (L ) Method Simplified Wet bulb (OF) - Wind speed (mph) 15.0 77 7.5 Construction quality Fireplaces Average 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft2 Btuh/ftZ'F ftz'F/Btoh Btureft2 Binh Btoh/ft= Btuh Walls 1613-19ad: Knee wall, asphalt shingles roof mat, r-19 kw ins, 1/2" gypsum board int fnsh Blk wall, stucco ext, r-4 ext bd ins, 8" thk, 1/2" gypsum board int fnsh Partitions 12C-0sw. Frm wall, 1/2" gyp.bd ext, r-13 cav ins, 1/2" gypsum board int fnsh, 2'7K4" wood frm, 16" o.c. stud Windows n 20 0.049 19.0 1.42 28 2.59 52 e 20 0.049 19.0 1.42 28 2.59 52 s 20 0.049 19.0 1.42 28 2.59 52 w 20 0.049 19.0 1.42 28 2.59 52 all 80 0.049 19.0 1.42 114 2.59 207 n 534 0.201 4.1 5.83 3113 4.06 2168 e 126 0.201 4.1 5.83 736 4.06 513 s 611 0.201 4.1 5.83 3561 4.06 2481 w 317 0.201 4.1 5.83 1846 4.06 1286 all 1588 0.201 4.1 5.83 9257 4.06 6448 270 0.091 13.0 2.64 713 1.31 354 2A-2ov: 2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/8" n 7 0.330 0 9.57 66 8.52 59 thk; NFRC rated (SHGC=0.23); 50% drapes, medium; 1.33 ft overhang (3.2 ft window ht, 0.83 ft sep.); 6.67 ft head ht 2A-2ov: 2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/8" n 49 0.330 0 9.57 469 8.52 418 thk; NFRC rated (SHGC=0.23); 50% drapes, medium; 1.33 ft overhang s 33 0.330 0 9.57 313 8.52 279 (5.3 ft Window ht, 0.83 ft sep.); 6.67 ft head ht w 33 0.330 0 9.57 313 22.4 733 all 114 0.330 0 9.57 1095 12.5 1430 2A-2ov: 2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/8" a 16 0.330 0 9.57 156 21.6 353 thk; NFRC rated (SHGC=0.21); 50% drapes, medium; 1.33 ft overhang (5.3 ft Window ht, 3.9 ft sep.); 6.67 ft head ht - 2A-2ov: 2 glazing, clr low-e outr, air gas, vnl frm mat, dr innr, 1/4" gap, 1/8" a 16 0.330 0 9.57 156 21.6 353 thk; NFRC rated (SHGC=0.21); 50% drapes, medium; 1.33 ft overhang (5.3 ft window ht, 5.3 ft sep.); 6.67 ft head ht s 1 -fJpF wrightsoft- 2021-Jarr1214:51:14 •�R•t• "•�.-..� �••. Right-S iteC�Urriversa12021 21.0.02 RSU23628 Page 1 ACCk aterstone1820AGR\Lot23BIkiWaterstorte1820AGR.np Calc=MJ8 FrontDoorfaces: E 213-2fv: 2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/8" e 7 0.33C thk; NFRC rated (SHGC=0.31); 9 ft overhang (1.4 ft window ht, 0.5 ft sep.); 6.67 ft head ht 2B-2fv: 2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/8" a 14 0.330 thk; NFRC rated (SHGC=0.31); 50% drapes, medium; 9 ft overhang (6.8 ft window ht, 2 ft sep.); 6.67 ft head ht 2A-2ov: 2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/8" s 16 0.330 thk; NFRC rated (SHGC=0.23); 50% drapes, medium; 1.33 ft overhang (5.3 ft window ht, 0.8 ft sep.); 6.67 ft head ht 10C-v: 2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/8" w 18 0.550 thk; NFRC rated (SHGC=0.70); 11.5 ft overhang (6.7 ft window ht, 0.5 ft sep.); 6.67 ft head ht 2A-2ov: 2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/8" w 33 0.330 thk; NFRC rated (SHGC=0.23); 50% drapes, medium; 11.5 ft overhang (5.3 ft window ht, 0.5 ft sep.); 6.67 ft head ht Doors 11 JO: Door, mtl fbrgl type a 20 0.600 Ceilings 16B-30ad: Attic ceiling, asphalt shingles roof mat, r-30 cell ins, 5/8" 1835 0.032 gypsum board int fnsh Floors 22A-tpl: Bg floor, light dry soil, on grade depth 212 0.989 -0 pi- wrilghtsc ft- �• �--«��.•. Right-Sute®UNversal2021 21.0.02 RSU23828 ..aterstore1820AGR1Lot23BIk1WaterstorLe1820AGR.np Calc=WB FrontDoorfaces: E 0 9.57 67 11.6 81 0 9.57 130 13.6 185 0 9.57 156 8.52 139 0 16.0 285 16.2 289 0 9.57 313 8.52 279 6.3 17.4 355 17.6 359 30.0 0.93 1703 1.69 3100 0 28.7 6080 0 0 2021-Jarr1214:51:14 Page 2 -�- wrightsoft® Project Summary Entire House DEL AIR HTG, A/C & REFRIG. INC 531 CODISCO WAY, SANFORD, FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web: W W W.DELAIR.COM For: ADAMS HOMES 5360 Lugo Street, Fort Pierce, FL 34951 Notes: JA8-18-15 Change to 3.0 ton 2/16/16 S. Finch L. S. 1-12-21 VWK Weather: Winter Design Conditions Outside db Inside db Design TD St Lucie Co Intl, FL, US Job: Lot 23 Block 1 Waterston... Date: By: DCS Summer Design Conditions 41 °F Outside db 70 OF Inside db 90 75 OF OF 29 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 57 gr/Ib Heating Summary Structure 24350 Btuh Ducts 4220 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 28571 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Area (ft2) Heating 1820 Cooling 1820 Volume (ft3) 18350 18350 Air changes/hour 0.38 0.20 Equiv. AVF (cfm) 116 61 Heating Equipment Summary Make Carrier Trade CARRIER Model 25HBC537AP03 AHRI ref 204837926 Efficiency Heating Input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat Capacity balance point = 36 °F 8.5 HSPF 34600 Btuh Qa 47°F 27 OF 1167 cfm 0.041 cfm/Btuh 0.30 in H2O Backup: Input = 8 kW, Output = 25920 Btuh,100 AFUE Sensible Cooling Equipment Load Sizing Structure 20615 Btuh Ducts Central vent (0 cfm) 5777 0 Btuh Btuh (none) Blower 0 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Equipment sensible load 26392 Btuh Latent Cooling Equipment Load Sizing Structure 3364 Btuh Ducts Central vent (0 cfm) 1403 0 Btuh Btuh (none) Equipment latent load 4767 Btuh Equipment Total Load (Sen+Lat) 31159 Btuh Req. total capacity at 0.75 SHR 2.9 ton Cooling Equipment Summary Make Carrier Trade CARRIER Cond 25HBC537AP03 Coil FX4DNB037L00 AHRI ref 204837926 Efficiency 12.5 EER,15.5 SEER Sensible cooling 26250 Btuh Latentcooling 8750 Btuh Total cooling 35000 Btuh Actual airflow 1167 cfm Air flow factor 0.044 cfm/Btuh Static pressure 0.30 in H2O Load sensible heat ratio 0.85 Calculations approved byACCAto meet all requirements of Manual J 8th Ed �"� wrigi�tsoft' �� • ^• ^-- �• •• RigM-Sate®Universal 202121.0.02RSU23828 2021-Jarr1214:51:14 aterstone1820AGR\Lot23BIkiWaterstone1820AGR.np Calc=MJ8 FrontDoorfaces: E Page -�- wrightsoft- Right-M Worksheet Entire House DEL AIR HTG, A/C & REFRIG. INC 531 CODISCO WAY, SANFORD, FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web: W W W.DELAIR.COM Job: Lot 23 Block 1 Waterstone182... Date: By: DCS 1 2 Room name E)posed wall Entire House BDRM2 3 Room height 212.0 ft 36.0 ft 4 Room dimensions 10.0 ft d 10.0 ft heaf/000l 5 Room area 1835.0 ft2 169.0 112 13.0 x 13.0 it Ty Construnumber ( B Or HTM (Btuh/ft2) Area (ft2) or Load Area (ft2) Load perimeter (it) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 L--G Blk wall, shtcco ext 2A 2ov _ ;:.., _..0 6.49 0.201 ..x,-n-, n -1, 42 5.83 1-_2,59 4.06 590 -_.2:. ., 20 534 s 28 3113 �-_- v 52 2168 _a, 100 0 �0 100 0 583 , . 0 . 406 0.330 n 9.57 8.52 7 0 66 59 11 _ W _. 2A 2ov_ _16&19ad _ 0 330 n 9.57 8.52 T.2;59 49 w 20 �_._. 0 2Q 469 28 _ 418 >v�. ;:=52 0 0 0 0 0 0 0 0 0 0 0 0 0 Blk wall, stucco ext 2A-2ov 2A-2ov 0.201 0.330 a a 5.83 9.57 4.06 21.62 200 16 126 0 736 156 ._._ u0 0 0 0 513 353 0.330 a 9.57 21.62 16 0 156 353 0 0 0 2B-2fv 2B-2fv 0.330 0.330 a a 9.57 9.57 11.58 13.59 7 14 7 11 67 130 81 185 0 0 0 0 0 0 W 11J0 16619ad ._ ._ .N-... 0.600 �'Y 0049 a ,,s.0 1740 _ 1;42 17.58 _.. 2.59 20 ._ . 20 20 .,a, 355 - 28 359 52 0 0 0 0 0 _ 0 0 0 w r Blk wall stucco eM 2A 2ov 0 201 0.330 s s 5.83 9.57 4.06 660 _.« _20 611 .. 3561 _ 2481 « ._ 130 130 758 p 528 2A 2ov 8.52 33 33 313 279 0 0 0 0 W 1,6B 19ad 0.330 s 9.57 8.52 - 16 - 16 156 139 0 0 0 0 VI/ �_ Blk wall, stucco ext 10C-v 0.201 0.550 w w -._ .42 5.83 15.95 __2,59 4.06 16.20 20 ~� LL 400 18 20. 317 18 z 28 1846 285 .. 52 1286 289 0 130 0_., ~ 4 114 - 663 - _ 0, 461 2A-2ov 2A 2ov 0.330, 0 330 w w 9.57 9.57 22.43 8 33 2 313 733 0 16 0 1 0 156 0 367 P _.__-_____. _ 12C Osw -_ r _0 09.1 _ 2 64 _52 131 3333 270 313 _� 279 0 0 0 C 16830ad _w 0.032 0.93 1.69 1835 1835 1703 " 3100 169 169 157 6 .. �, ._t _ ..........._._i.--_.- w,...--...-_. ..n.. .__._m.., ..._..__... _........».... __n ,.r......1 'A..aub«.. �.,: ,...__....... »J..x..,®.3.- ..._....._...w,. ,...«.... ..w.J..., r..Y gip._. _.._ .«...-.,p 77 6 c) AED excursion 893 102 Envelope loss/gain 20647 14530 3349 2149 12 a) Infiltration b) Room ventilation 3704 1035 691 193 0 0 0 0 13 Internal gains: Occupants @ 230 5 1150 0 Appliancesrother 0 3900 300 Subtotal (lines 6 to 13) 24350 20615 4040 2642 Less extemalload Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 0 0 0 15 Ductloads 171/. 28% 24350 4220 20615 5777 17% 28% 4040 700 2642 740 Total room load Air required (dm) 28571 26392 4740 383 3150, 1571 1392 Calculations approved byACCAto meet all requirements of Manual J 8th Ed -�• wrigtitsoftm ,gC"56A Right-SuteGUriversal 2021 21.0.02 RSU23828 2021-Jarr1214:51:14 aterstone1820AGR\Lot23BIk1 Waterstore1820AGR.rLp Calc= W8 FrontDoorfaces: E Page 1 - - wrightsoft Right-M Worksheet Job: Entire House Date: DEL AIR HTG, A/C & REFRIG. INC By. 531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-333-2665 Fax:407-333-3853 Web: W W W.DELAIR.COM Hoorn name BATH 2 2 Exposed wall 6.0 ft 3 Room height 10.0 ft heaUcool 4 Room dimensions 13.0 x 6.0 ft 5 Room area i 7U n - Lot 23 Block 1 Waterstone182... DCS BDRM3 13.0 ft 10.0 It heaticool 13.0 x 13.0 ft "-- IUv.0 Ir- Ty Construction number U-value (BtuhrlC�� Or HTM Area (ft') Load Area (ft) Load (Btuh/tz) or perimeter (ft) (Btuh) or perimeter (it) (Btuh) Heat Cool Gross N/R/S Heat Cool Gross N/P/S Heat Cool 6 Blk wall, stucco ext 2A 2ov 0.201 n -1.42 5.83 2.59 4.06 w.' 0 0 ^ _� _ 0 _. _0 0 _ w 0 ' 0 x- a0 ... w« _.0 0 0 0 0 0 0.330 n 9.57 8.52 0 0 0 0 0 2A 2ov _ ;Blk 1 0.330 n --9.57 v �5.83 Y8.52 2:59 w. __ y 0 _ 0 0 y 0 0 0 0 . Q , 0 0 a 0 0 0 0 p 0 0. Blk wall, stucco ext 1, stucco 2A-2ov 2A-2ov 0.201 0.330 e a 9.57 4.06 21.62 0 p 0 0 0 0 _ 0 O -__.� O __ w w O 0 0 _, ___. _0 0 0 0 0.330 a 9.57 21.62 0 0 0 0 0 0 0 0 2B-2fv 0.330 a 9.57 11.58 0 0 0 0 2B-2tv 0.330 a 9.57 13.59 0 0 0 0 0 0 0 0 0 0 0 _ 11J0 _ _ :166-19adu ^_ 0 600 �rn 0049 _e _ _� ._ 17.40 �__-1.42 17.58 _ _2.59 0 _ . �--0 _ 0 __w__ _ _ 0 'w 0 0 0 0 0 0 _0 Blk wall stucco ext 2A 2ov 0.201 0.330 s s 5.83 9.57 4.06 60 __0 60 _ 350 _ 2 44 130 114 663 461 2A 2ov 8.52 0 0 0 0 0 0 0 0 -W 166-1.9ad._ ., -_ 0.330 ..__.;.._0049 _ s _w 9.57 1.42 8.52 259 _ _0 h 0 �_�v_ 0 0 16 16 156 139 Bilk wall, stucco ext 10C-v 0.201 0.550 w w 5.83 15.95 4.06 16.20 . µ. 0 0 . _.0 0 0 0 0 0.0.00,.0 0 0 0 p 0 0. 2A-2ov 0.330 w 9.57 22.43 0 0 0 0 0 0 0 0 2A 2ov j2C Osvia_ _. :°_ 0.330 .__ .0091: w 9 57 -;2;84 8.52 . _.1.3.1 0 _-..�. >. 0 0 0 0 0 0 _ 0 0 0 _... -r ,C E 16B 30ad �_`` 22A tplQfl _ 0032 0.93 1,69 78 78 . 72 ' 132 _ 169 169 _ 157 µ 286 - F....,.,y.-..-. « ...-...._-.__..... 6 c) AED excursion -18 57 Envelope loss/gain 594 357 1349 829 12 a) Infiltration b) Room ventilation 115 32 249 70 0 0 0 0 13 Internal gains: Occupants Qa 230 0 0 0 Appliances/other 0 0 300 Subtotal (lines 6 to 13) 709 389 1598 1199 Less external load 0 0 Lesstransfer 0 0 Redistribution 0 0 0 0 0 0 14 15 Subtotal Duct loads 709 389 0 1598 0 1199 17% 28% 123 109 17% 28% 277 336 Total room load Air required (cfm) 832 498 1875 1535 34 22 77 68 Calculations approved byACCA to meet all requirements of Manual J 8th Ed -�- wrigR�tsoft� 2021-Jan-1214:51:14 ,qC"�p Right -Slate® Uriversal 2021 21.0.02 RSU23828 Page t aterstone1820AGR\Lot23BIk1Waterstone1820AGR.np Calc=MJ8 FrontDoorfaces: E - - wrightsoft, Right-M Worksheet Entire House DEL AIR HTG, A/C & REFRIG. INC 531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-333-2665 Fax:407-333-3853 Web: W W W.DELAIR.COM Job: Lot 23 Block 1 Waterstone182... Date: By: DCS 1 2 Room name E)p°sedwall DINING/FOYER DENBDRM4 3 4 Room height Room dimensions 10.0 It 25.0 It heat/cool 10.0 If 31.0 ftheat/cool 5 Room area 276.0 ft 1.0 x 276.0 ft z 13.0 x 13.0 ft 169.0 ft z Ty U-val ze (BtuhAt -f Or HTM Area (ftz) Load Area (flz) Load =number (BtuhRtz) or perimeter (ft) (Stuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W Blk wall, stucoo �0 T F �0 J .. ext 2A 2ov 0.201 0.330 n n 5.83 9.57 4.06 8.52 0 0 0 0 50 50 291 203 I�_-�G 2A 2ov ._., Blk 0.330 n 9.57 8.52 0 0 0 0 0 0 0 0 0 0 0 0 0 0 wall, stucco ext 2A-2ov 2A-2ov 0.201 0.330 a a 5.83 9.57 4.06 21.62 70 169 0 118 0 � 130 16 97 0 567 156 -395 353 29 0 0 0.330 a 9.57 21.62 0 0 0 0 16 0 156 353 2B-2fv 0.330 a 9.57 11.58 7 7 67 81 26-2fv 0.330 a 9.57 13.59 14 11 130 185 0 0 0 0 0 0 _ W . _._ 11J0 168�19atl.. __.. ::.: _ r _0.600 - -0'.0- e_. 17.40 _..__ 17.58 __ .__ 20 r .0 ,__ '20 v 0 _ 355 w - 359 0 0 0 0 0 0 : _s , 'A2 _,__.:2,59 V)/ Blk wall, stucco ext 2A-2ov 0.201 0.330 s s 5.83 9.57 4.06 110 ._ 77 ' v451 M� 314 130 130 .._w.� -_0 758 ....• 0: 1 528 2A 2ov 8.52 33 33 313, 279 0 0 0 0 Blk wall, stucco ext _ 0.330 �__ _0049 0.201 s w... w 9.57 1,,42 5.83 8.52 _2.59 4.06 _ 0 0 0 - 0 - LL0 0 _.__� 0 � p 0 - 0 0 0 0 " 0 0 0 ` 0 " -'-0 0 10C-v 0.550 w 15.95 16.20 0 0 0 2A-2ov 0 0 0 0 0 0 0 2A 2ov 0.330 w 9.57 22.43 0 0 0 0 0 0 0 0 _ :P `126Osw _0 0 330 091 w 9.57 8.52 0 0 .ZO 0 ,: ,185 0, ti 0 .,_ -0 0 0 0 0 . C 16B 30ad_ 0032 093 668 _1 69 Q00 _._276 L276 _ 276 __ 256 ',-._,-7.17 466 169 �_..� M 169 w ..�0,0: 157 286 __ _ _25 _:. 0 _ _ z 777 �.._-._..__ ..-...w.::.at.-..«. �. ...._....-....,n_ :.:s,._«.._-......-.. -. :. _...�.,�s.._., ....._...-� ._. __....,ter _. ._...�..... �_...-x_:.....A._... 6 c) AED excursion -100 115 Envelope loss(gain 2642 1792 2975 2233 12 a) Infiltration b) Room ventilation 345 97 595 166 0 0 0 0 13 Internal gains: Occupants@ 230 1 230 0 Applianoes�other 0 0 300 Subtotal (lines 6 to 13) 2988 2119 3570 2699 Less wdemalload 0 0 Lesstransfer 0 0 0 Redistribution 0 0 0 14 15 Subtotal Duct loads 0 2988 0 2119 0 3570 0 2699 17% 28% 518 594 170/6 28%1 619 756 Total room load Air required (cfm) r--F3506 506 713 2120 4189 6 �153 171 Calculations approved byACCA to meet all requirements of Manual J 8th Ed �- -� wrigFitsoft- ACCX Right-Sute®UNversal2021 21.0.02 RSU23828 2021-Jan-7214:51:14 aterstone1820AGR\Lot23BIk1Waterstone1820AGR.np Calc=Wa FrontDeorfaces: E Page -- wrightsott9 Right-JO Worksheet Entire House DEL AIR HTG, A/C & REFRIG. INC 531 CODISCO WAY, SANFORD, FL 32771 Phone: 407-333-2665 Fax:407-333-3853 Web: W W W.DELAIR.COM Job: Lot 23 Block 1 Waterstone182... Date: By: DCS 1 2 Room name Etposed wall FAMILYRM MSTR 8DRM 3 Room height 13.0 It 10.0 It heaUmol 41.0 It 10.0 It heat/cool 4 5 Room Room diimensions ea 13.0 x 22.0 ft 14.0 x 17.0 ft 286.0 ftZ 238.0 ftz Ty Construction U-value Or HTM Area (ft') Load Area (ft) Load number (Btu F) (Btuh/ftz) or perimeter (ft) (Btuh or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 �W 16619ad._„� u_a,n _....w..;0049n::n + 142 x2:59 .20 _ 20 `� 28 52_0 0 0 0, Blk wall, stucco ext 2A 2ov 0.201 0.330 n n 5.83 9.57 4.06 8.52 0 0 0 0 0 0 - p 170 - y154 4 ~ m 896 624 2ov 0 0 0 0 0 2A _ 0.330 w�80.201 n 9.57 _ s5.83 8.52 _w 0 _"_ 20 0 0 `.20 28 0 52 16 t0 0 p 156 0 139 �. Blk wall, stucco ext 2A-2ov 0.330 e a 9.57 4.06 21.62 0 0 0 0 0 0 .0 0 0 0 _._w. 0 0 0 0 p 0 2A-2ov 0.330 a 9.57 21.62 0 0 0 0 0 0 0 0 2B-2fv 0.330 a 9.57 11.58 0 0 0 0 0 0 0 0 2B-2fv 0.330 a 9.57 13.59 0 0 0 0 0 0 0 0 11d0 Blk wall, stucco ext 0600 0.201 e K s 17.40, 5.83 17.58 59 4.06 0 . 20 .._ . 0 - 0 0 _:.._:.a. 20 . �.� 28 0 0 0 52 -._ 0 _ 0 : ..__ :a 0 100 0 0 �y 100 0 0 583 0 'Q. 406 2A 2ov 0.330 s 9.57 8.52 0 0 0 0 0 0 0 0 ^� 2A 2ov _ _ 0.330 s 9.57 8.52 0 0 0 0 0 0 0 0 W __ 16619ad_ 0 049 ' w.. 1:.42 -.,- ,_2.59 _ ._ _ 20 _ .,_.. _ w. .20 _ a 28 _ -_ 52� VVV���lll -G Blk wall stucco extl�- 10C-v 0201 0.550 w w 5.83 15.95 4.06 16.20 130 18 79 463 18 285 _ 323 289 140 0 124 0 721 0 502 0 2A 2ov 0.330 w 9.57 22.43 0 0 0 0 16 1 156 367 _.� _ P 2A 2ov 16C Osw :u 0.330 Q,091 w 9.57 2 64.. 8.52 33 33 313 279 0 ,0 0 0 0 _0 0 -'....._6 C 16B 30ad _ 0.032 0 93 -7ffl .._� 1.69 286 286 265 483 v_ 238 -,_ .... _ 238 41, .�.. ��:., �221_ . � 402 a..- t--�- •.- _._ P, ...... a__......_«:. ._.. ...J_.w".:... -✓.._._.w,-:..r:.»..o. .........._...:.ss.,..,,..--..:«:.t.L......r...:.m_.1_w.�._..«. t. ._.�..._>...:..> �.......,... .._ ....». ._�................,..i ....,,...;:,. ...,:...:.`n: ...:............_..u.__.._._..r,.,s.�._. h..v...s.�..._....................,..."...... ,..:.-_..... .... 6 c) AED excursion 1022 22 Envelope loss/gain 1813 2603 3909 2462 12 a) Infiltration 403 113 787 220 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 3 690 1 230 Appliancestother 600 600 Subtotal (lines 6 to 13) 2216 4006 4696 3512 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2216 4006 4696 3512 15 Ductloads 17% 28% 384 1123 17% 28% 814 984 Total room load Air required (dm) 2600 5128 5510 4496 1061 2271 225 199 -14- Calculations approved byACCAto meet all requirements of Manual J 8th Ed 2021-Jarr1214:51:14 wrigtitsotFt� A Right-SuteC�Uriversal 2021 21.0.02 RSU23828 Page 4 aterstone1820AGR\Lot23BIk1Waterstone1820AGR.rtp Calc=MJ8 Front Door faces: E -N- wrrightsoft° Right-M Worksheet Entire House DEL AIR HTG, A/C & REFRIG. INC 531 CODISCO WAY, SANFORD, FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web: W W W.DELAIR.COM Job: Lot 23 Block 1 Waterstonel82... Date: By: DCS 1 Room name M BATH M WIC 2 Exposed wall 12.0 It 0 ft 3 4 Room height Room dimensions 10.0 It heat/000l 10.0 ft heaV000l 5 Room area 119 0 ft2 1.0 x 119.0 It 7.0 x 7.0 ft 49.0 ft2 Ty Construclion U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft--n (B1uhRt2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 jff_770491.42 Vl/ Blk wall, stu000 ext 2A 2ov 0201 n 5.83 2;59 4.06 Q 120 0 _ t 113 0 659 ._. 0 459 4' 0 .:__: 0 0 - 0` '" p I�-�-G 2A 2ov 0.330 0 330 n n 9.57 9 57 8.52 8 52 7 0 0 0 66 0 59 0 0 0 0 0 0 0 0 0 11 _W 16B 19adu - QMµ _ 0 _. _ .0 .a:. - 0 a� _ . M. 0 :. Blk wall, stucco ext 2A-2ov 0.201 0.330 a a 6.83 9.57 4.06 21.62 0 0 0 0 0 ^ 0 0 _,.. 0 0 0 0 0 0 u- p 0 2A-2ov 0.330 a 9.57 21.62 0 0 0. 0 0 0 0 0 213-2fv 0.330 a 9.57 11.58 0 0 0 0 0 0 0 0 2B-2fv 0.330 a 9.57 13.59 0 0 0 0 0 0 0 0 _11J0 0.600 -0.049 a s._. 17.40 ._-,v142 17.58 2;59 0 lb 0 _ 0 _____ 0 0 0 _ 0 0 Blk wall, stu000ext 2A 2ov 0201 0.330 s s 5.83 9.57 4.06 8.52 0 0 0 0 0 m0 0 0 0 2A 2ov 0 0 0 0 0 0 0 0.330 s 9.57 8.52 0 0 0 0 0 0 0 0 _W VVV���lll 16B 19ad� ..__.v_ Blk will, stu000 ext 10C-v _. 0%9 0.201 0.550 w w w _ 1:42 5.83 15.95 259 4.06 16.20 0..__ 0 0 0. 0 0 _:0 0 0 __ 0 �._ 0 0 s .wQ -'" 0 0 _ 0 0 _ 0 2A-2ov 0.330 w 9.57 22.43 0 0 0 0 0 0 0 0 0 0 0 P 2A 2ov _ 12C Osw 0.330 0 o91 w - 9.57 2 64 8.52 l 31 0 .._ 0 _0 �, 0. _ 0_ - ��.0 0- r :O. 0 :_. Q 0 0 6 0 %'p C 16B 30ad•_ � 0.032 _ OM 1.69 119 119 110 201 x ._ 49, - .0 49 _ _ - 45 -1< _. _ 83 28.68 . 0 00 ._� ._ _ 119 _... _.. __� ., • .,, . _.__...«k .._ _....... __.._._.... ._.,_..,v.,.v. .tea.."m..._ ._._.,._.._. .._.,..,..� t' _�_.. ..__...»._... .....�.... 6 c) AED excursion -35 -4 Envelope loss/gain 1180 684 45 79 12 a) Infiltration 230 64 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Ooa/pants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1410 748 45 79 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1410 748 45 79 15 Ductloads. 17% 28% 244 210 170/6 28% 8 22 Total room load Air required (c(m) 1655 958 53 101 681 421 2 4 Calculations approved byACCA to meet all requirements of Manual J 8th Ed -�- wrigF�tsoTt- 2021-Jarr1214:51:14 A �k Right-Sute®Urtiversal 2021 21.0.02 RSU23828 Page 5 aterstore1820AGR�Lot23BlkiWaterstone1820AGR.rnp Caic=MJ8 FrontDoorfaces: E -�+ wrightsofta Right-JO Worksheet Entire House DEL AIR HTG, A/C & REFRIG. INC 531 CODISCO WAY SANFORD, FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web: W W W.DELAIR.COM Job: Lot 23 Block 1 Waterstonel82... Date: By. DCS 1 Room name KrrCHEN/NOOK LAUNDRY 2 3 Exposed wall Room height 29.0 It 6.0 ft 4 Room dimensions 10.0 It heaVocol 10.0 it heat/cool 5 Room area 1.0 x 246.0 ft 246.0 ft2 6.0 x 6.0 ft 36.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2- `F) (BtuM2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 .:. 0 LBlk --G wall, stucco ext 2A 2ov 0.201 0.330 n n 5.83 9.57 4.06 8.52 150 117 0 0 684 4 476 0 0 µ0 0 2ov 0 0 0 0 0 0 11 W� 2A _� _ J.00: gad= _� 0330 0 049 , ryn .e _ _�_9.57 T: 142 __ 852 __ 33 __ _ 0 . 0 : 0 "0 313 w. 0 _ 279 Q 0 0 0 0 0 ; 0 0 -� 2`,59 Blk wall, stucco ext 2A-2ov 0.201 0.330 a a 5.83 9.57 4.06 21.62 . 0 0 0 0 0 0 0 `" __ 0 0 _ _ 0 0 _ _ 0 0 0 0 2A-2ov 0.330 a 9.57 21.62 0 0 0 0 0 0 0 0 2B-2fv 0.330 a 9.57 11.58 0 0 0 0 0 0 0 0 26-2fv 0.330 a 9.57 13.59 0 0 0 0 0 0 0 0 W_ _0 11j0 0600 049 e_ _: s:_ 1740 1:42 1758 0 0 0 :0 0 0 0 0 0 p 0 0. 0 _ 0. Blk wall, stucco ext 2A-2ov 0.201 0.330 s s 5.83 9.57 4.06 8.52 0 0 0 »0 0 0 « µ�0 _ 0 2A 2ov 0 0 0 0 0 0 0 0 _ _ 0.330 s .__'__9.57 8.52 �T_ 0 0 n 0 _ 0 - 0 0 0 0 .16619ai.A;-Y Blk wall, stucco ext 10C-v 0.201 0.550 w w 5.83 15.95 _�_2.59 4.06 16.20 .�..,_.,..�- 0 0 0 0 0 0 0 0 _ _,0 0 0 _ __.. 0 0 0 _ i a 0, 0 0 .Q W'0 2A-2ov 0.330 w 9.57 22.43 0 0 0 0 0 0 0 0 0 2A 2ov s _ 0330 _ w 9.57 852 0 0 ,40 0_ _ .369 r0 . .�_183 _ 0 . e 60 0 Y 60 0 0 C F 16B 30ad 0 032 0 93 1 69 246 246 228 832 _ 416 ._ m .,0 __, 36 _�_. 36 33 _ 61- .t._..-.. _-.,..-:.-....» ....... J-..,.....; ._n..�_::.,..,..... ...:. ».-...............; --,_ r,.._ _....s'.».:.w..«..-.-..:. a......... ......... wr.....�.:.,.-..__.,+ ....r....d. .....:...:..... _s.««_......�'.. .t ».+4 .�.J.. cw .-..._:�....w....,.._.. m. t_....... »...�.M1.r.» .........>«:,.... V-...n .»v« _»>.«,. _«w ..............._«+...... ....n _'�.»v..wM> ' ...z n::J:iJ..'.:.n... _.,.. _.w..__.: n......,._«»-...»,.:. -.... _.-s,.. �... .. «.a. 3:..7 ...�.__a5....-.. ,......✓... _..:a�... ,c.. �.,..-_.,...._....:_. ........:.....t.r ..,......X-..__..»........:. __...u_....__.._....> _ _w _ � _,« __......_._r.�.U_..._in ._...._..-_,r.............>.. ...._- .«......._.... .« ......_..« L..n _ 1....... u.... ...__.....«. ...-...«.. a.... wdv_..,. ....Mn. 4._t� x_.. x.._.«.. ... .�r.._._..-..c ... ......:.......1.«_ .__.........« r_. �_...w.. ..._-_. .. __.. _..�x�` .�i...... ,.......e-...« v.a_.._ �...._..... _ _..-. v_..� _.._�- ....._.emu.... ..._...._.......:,rs__ _�_� __..�......+.i-.....�.�-_.._.... _.......�.�.._.........t.�...._ _177 _...�......:':........,.. ..x.-...._._-..a. ...:e..-:.. �. _...._a_... .. «....._.... _..... ..v __..-...._ ....,_...t-.5�., ... ..wu..F:�ti..o..,> w.M...._.... ec�.......,_.. Mw..°..t..«..-r.t _'«.w.w:Ja' 1..... .+._n.,.�......._:�.. .,.a.._........... --. ...vm .......3..-...«._....... _z�u..+.._ ,r.y. ,ate---. ......_...s.vs'r.n. _ a._..ta_.a_ v w-�....-n:�.er.- ..._..»._ w .,._...... _..._�..-.: _.........r 6 c) AED exarsion -119 33 Envelope loss/gain 2426 1235 364 106 12 a) Infiltration 288 80 0 0 b) Room ventilation 0 0 0 0 13 Intemalgains: Occupants 230 0 0 0 0 Appliances/other 1200 600 Subtotal (lines 6 to 13) 2714 2515 364 706 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 14 15 Subtotal Ductloads 2714 2515 364 706 17% 28% 470 705 170/6 28% 63 198 Total room load Air required (cfm) 3184 3220 427 904 130 142 17 40 Calculations approved byACCA to meet all requirements of Manual J 8th Ed -*- wrigtitsoft^ ACa, Right -State® Universal 2021 21.0.02 RSU23828 2021-Jarr1214:51:14 aterstone1820AGR\Lot23Blk1 Waterstone1820AGR.np Calc= MJ8 Frord Door faces: E Page 6 wrightsofts Duct System Summary Job: Date: Entire House By. DEL AIR HTG, A/C & REFRIG. INC 531 CODISCO WAY SANFORD, FL 32771 Phone: 407-333-2665 Fax: 407-333-3853 Web:WWW.DELAIR.COM For: ADAMS HOMES 5360 Lugo Street, Fort Pierce, FL 34951 Lot 23 Block 1 Waterston... DCS External static pressure Heating 0.30 in H2O Cooling 0.30 in H2O Pressure losses 0.06 in H2O 0.06 in H2O Available static pressure 0.24 in H2O 0.24 in H2O Supply/return available pressure 0.120/0.120 in H2O 0.120/0.120 in H2O Lowest fri cti on rate 0.212 in/100ft 0.212 in/100ft Actual airflow 1167 cfm 1167 cfm Total effective length (TEL) 113 ft Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FIR (in) (in) Mat Ln (ft) Ln (ft) Trunk BATH 2 h 832 34 22 0.278 4.0 Ox 0 VI Fx 16.3 70.0 BDRM 2 h 4740 194 150 0.258 8.0 Ox 0 VI Fx 22.9 70.0 BDRM 3 h 1875 77 68 0.305 6.0 Ox 0 VI Fx 8.6 70.0 DENIBDRM4 h 4189 171 153 0.288 7.0 Ox0 VIFx 13.2 70.0 DINING/FOYER h 3506 143 120 0.314 7.0 Ox 0 VIFx 6.5 70.0 FAMILYRM c 5128 106 227 0.233 8.0 Ox 0 VIFx 17.9 85.0 st1 KITCHEN/NOOK c 3220 130 142 0.228 7.0 Ox 0 VIFx 20.1 85.0 st1 LAUNDRY c 904 17 40 0.223 4.0 Ox 0 VI Fx 22.7 85.0 st1 M. BATH h 1655 68 42 0.224 5.0 Ox 0 VI Fx 22.2 85.0 st1 M. WIC c 101 2 4 0.225 4.0 Ox 0 VI Fx 21.9 85.0 sti MSTR BDRM h 5510 225 199 0.212 8.0 Ox 0 VI Fx 28.2 85.0 sti ]--Trunk Name Type Htg (cfm) Clg (cfm) Design FIR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk st1 PeakAVF 549 655 0.212 612 14.0 0 x 0 VinlFlx ,` -- wrightsoft® 2021-Jarr1214:51:14 h•1e..4.nu.wu,...�„R,,,,y Right-Sute® Udversal 202121.0.02 RSU23828 ACCK...aterstone1820AGR1Lot23BIk1Waterstone1820AGR.np Calc=MJ8 FrontDoorfaces: E Paget Name Grille Size (in) Htg (Cfm) Clg (Cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mat Trunk rb1 Ox 0 1167 1167 0 0 0 0 Ox 0 VIFx wrightsoft, 2021-Jarr1214:51:14 t e•-. „•�_ -•, �,•�• w Right-SLdte®Urrversal2021 21.0.02 RSU23828 A+CA ...atersto-1820AGR1Lot23BIk1Waterstore1820AGR.np CaIc=W8 Front Door faces: E Paget 2020 : AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Lot 23 Block 1 Waterstone 1820 AGR Builder Name: ADAMS HOMES Street: 5360 Lugo Street Permit Office: City, State, Zip: Fort Pierce , FL , 34951 Permit Number: Y Owner: Jurisdiction: 661000 W Design Location: FL, ST_LUCIE CO INTL = — — U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. Breaks or joints in the air barrier shall be sealed. not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. The insulation in any dropped ceiling/soffit Access openings, drop down stairs or knee wall doors to shall be aligned with the air barrier. unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. Knee walls shall be sealed. with a material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors (including The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to above -garage maintain permanent contact with the underside of and cantilevered subfloor decking, or floor framing cavity insulation floors) shall be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall:;. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac 3s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Pyt.--nd-beh4nd l2aping and wiring. Shower/tub on exterior wall The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exteriorwalls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. In addition. insnectinn of Inn walls shall he in ,.ate. e ffi5 1/12/2021 3:34 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance) Method Applications for compliance with the 2020 Florida Building Code, Energy Conservation via the Residential Simulated Performance Alternative shall include: ❑ This checklist ❑ Form R405-2020 report ❑ Input summary checklist that can be used for field verification (usually four pages/may be greater) ❑ Energy Performance Level (EPL) Display Card (one page) ❑ HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7 ❑ Mandatory Requirements (five pages) Required prior to CO: ❑ Air Barrier and Insulation Inspection Component Criteria checklist (Table R402.4.1.1 - one page) ❑ A completed 2020 Envelope Leakage Test Report (usually one page); exception in R402.4 allows dwelling units of R-2 Occupancies and multiple attached single family dwellings to comply with Section C402.5 ❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed 2020 Duct Leakage Test Report - Performance Method (usually one page) 1/12/2021 3:33:12 PM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2020 Florida Building Code. Enerav Consprvatinn 7th Frlitirnn Jurisdiction: 661000 Permit #: Job Information , Builder: ADAMS HOMES Community: Lot: 23 Address: 5360 Lugo Street City: Fort Pierce State: FL Zip: 34951 Ai,r ,Leakage, Test Results: PassrngEres its must meet either the Pertoimance, Prescriptive, or ERLMethod 0 PRESCRIPTIVE METHOD -The building or dwelling: unit shall Be tested and venfid as having an air, leakage rate exceeding 7 air . yof,,;not changes per hour ati a,pressure..of 0.2 inch:wig. (5o Pascals} in Climate Zones 1"'nd2. PERFORMANCE or,,ERI`METHOD-The building.or dwelling 6'r ti,shall betested,and verified as having,an air leakage7ate of not`exceeding the selected:ACH(50) value, as shown on. Form R405=2020 (Performance) R406-202U secfion,talieled or (ERI), as infiltration, sub section AGH50. ACH(50) specified on F&m R405-2020-Enq* Cdlc (Performance). or R406-2020. (ERf): 7000 x 60 _ 18200 - _Method for calculating building volume: CFM(50) Building Volume ACH(50) O Retrieved from architectural plans F-1 PASS • Code software calculated When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated must be verified by building department. R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals) Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. Testing Company n Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2020 7th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: Issuing Authority: 1/12/2021 3:34:21 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 Florida Building Code, Energy Conservation, 7th Edition (20201 .- - - -/ Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: 5360 Lugo Street Permit Number: Fort Pierce , FL , 34951 KH A \IM A T/1 w�i w��• . Ir1AlY LJM 1 VIx r r%r—wU11CCIvir_N 1 5 - 5ee Individual code sections for full details. SECTION R401 GENERAL R401.3 Energy Performance Level (EPL) display card (Mandatory) The building official shall require that an energy display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law ❑ (Section 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD. SECTION R402 BUILDING THERMAL ENVELOPE ❑ R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. ❑ R402.4.1 Building thermal envelopeThe building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. ❑ R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required by the code official, an approved third party shall inspect all components and verify compliance. ❑ R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. ❑ R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where using tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the fireplace. Where using tight -fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907. I 1 R402.4.3 Fenestration air leakage. Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm .I� per square foot (1.5 Us/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 Us/m2), when tested according to NFRC 400 or AAMA/ WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Exception: Site -built windows, skylights and doors. 1/12/2021 3:34 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5 MANDATORY REQUIREMENTS - (Continued) R402.4.4 Rooms containing fuel -burning appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential. ❑ R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not more than 2.0 cfm (0.944 L/s) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. R403.1 controls. SECTION R403 SYSTEMS ❑ R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes, to be "substantially leak free' in accordance with Section R403.3.3. ❑ R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. ❑ R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: 1. Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the manufacturer's air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test. 2. Postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the entire system, including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. Duct leakage testing is required for Section R405 compliance where credit is taken for leakage, and a duct air leakage Qn to the outside of less than 0.080 (where Qn = duct leakage to the outside in cfm per 100 square feet of conditioned floor area tested at 25 Pascals) is indicated in the compliance report for the proposed design. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. ❑ R403.3.5 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.4 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41°C) or below 55°F (13°C) shall be insulated to a minimum of R-3. ❑ R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause degradation of the material. Adhesive tape shall not be permitted. R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory). If heated water circulation systems are installed, they shall be in accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe shall ❑ be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. ❑ R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 1/12/2021 3:34 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5 MANDATORY REQUIREMENTS - (Continued) R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3'% inches (89 mm) in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies (Mandatory). R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature setting range shall be from 100°F to 140°F (38°C to 60oC). R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water -heating systems to be turned off. R403.5.6.2 Water -heating equipment. Water -heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water -heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1. El R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors, and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar water -heating systems should meet the following criteria: 1. Be installed with atilt angle between 10 degrees and 40 degrees of the horizontal; and 2. Be installed at an orientation within 45 degrees of true south. R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. R403.6.1 Whole -house mechanical ventilation system fan efficacy. When installed to function as a whole -house mechanical ventilation system, fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where an air handler that is integral to tested and listed HVAC equipment is used to provide whole -house mechanical ventilation, the air handler shall be powered by an electronically commutated motor. R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19, space permitting, or R-10 otherwise. R403.7 Heating and cooling equipment. El on Equipment sizing (Mandatory). Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFIr_Ary FAN LOCATION AIRFLOW RATE MINIMUM (CFM) MINIMUM EFFICACY a (CFM/WATT) AIRFLOW RATE MAXIMU IV (CFM) HRV or ERV Any 1.2 cfm/watt Any Range hoods Any 2.8 cfm/watt Any In -line fan Any 2.8 cfm/watt Any Bathroom, utility room 10 1.4 cfm/watt <90 Bathroom, utility room 90 2.8 cfm/watt Any For SI: 1 cfm = 28.3 Umin. a. When tested in accordance with HVI Standard 916 1/12/2021 3:34 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5 MANDATORY REQUIREMENTS - (Continued) R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section R403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's expanded performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space. Exceptions: 1. Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is less than the 2. calculated total sensible load but not less than 80 percent of that load. When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Florida Building Code, Energy Conservation —Commercial Provisions in lieu of Section R403. R403.9 Snow melt and ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F (10°C), and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40oF (4.8°C). ❑ R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots. R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar- and waste -heat -recovery pool heating systems. 3. Where pumps are powered exclusively from on -site renewable generation. 1/12/2021 3:34 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 5 QR403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required. R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal ❑ efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas (Mandatory).The energy consumption of electric -powered portable spas shall be controlled by the requirements of APSP-14. DR403.13 Dehumidifiers (Mandatory If installed, a dehumidifier shall conform to the following requirements: 1. The minimum rated efficiency of the dehumidifier shall be greater than 1.7 liters/ kWh if the total dehumidifier capacity for the house is less than 75 pints/day and greater than 2.38 liters/kWh if the total dehumidifier capacity for the house is greater than or equal to 75 pints/day. 2. The dehumidifier shall be controlled by a sensor that is installed in a location where it is exposed to mixed house air. 3. Any dehumidifier unit located in unconditioned space that treats air from conditioned space shall be insulated to a minimum of R-2. 4. Condensate disposal shall be in accordance with Section M1411.3.1 of the Florida Building Code, Residential. R403.13.1 Ducted dehumidifiers. Ducted dehumidifiers shall, in addition to conforming to the requirements of Section R403.13, conform to the following requirements: 1. If a ducted dehumidifier is configured with return and supply ducts both connected into the supply side of the cooling system, a backdraft damper shall be installed in the supply air duct between the dehumidifier inlet and outlet duct. 2. If a ducted dehumidifier is configured with only its supply duct connected into the supply side of the central heating and cooling system, a backdraft damper shall be installed in the dehumidifier supply duct between the dehumidifier and central supply duct. 3. A ducted dehumidifier shall not be ducted to or from a central ducted cooling system on the return duct side upstream from the central cooling evaporator coil. 4. Ductwork associated with a dehumidifier located in unconditioned space shall be insulated to a minimum of R-6. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS R404.1 Lighting equipment (Mandatory). Not less than 90 percent of the lamps in permanently installed luminaires shall have an efficacy of at least 45 lumens -per -watt or shall utilize lamps with an efficacy of not less than 65 lumens -per -watt. R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights. 1/12/2021 3:34 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5