Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Truss
- r V !( 258 Southhall Lane, Suite 200 fiF; Maitland, Florida 32751 D P: (321) 972-0491 1 F: (407) 880-2304 E: info@fdseng.com Website: www.fdseng.com ENGINEERING ASSOCIATES January 18, 2021 -RECEIVED Building Department FEB 12 2020 Ref: Adams Homes ST. Lucie County, permitting Lot: 23 Blk. 1 Subdivision: Waterstone Address: 5360 Lugo St. Model: 1820 A 3CF RH KA # 21-0182 Truss Company: Builders First Source Date of drawings: 1/11/21 Job No.: 2598015 Wind Speed: 160 Exposure: C Truss Engineer: Joaquin Velez To whom it may concern, We have reviewed the truss design package for the project referenced above. This truss package complies with the original design intent and the underlying structure will accommodate all indicated loads. We approve the truss package without comment based upon the truss layout and truss profiles supplied to us by the Truss Company with truss profiles sealed by the Truss Engineer. Please note, this review is only for general conformance with the design concept of the project. Contractor or sub -contractor is responsible for matching all structural components and details shown in the construction documents. Contractor or sub -contractor is also responsible for confirming all quantities and dimensions; selecting appropriate fabrication processes and techniques; and coordinating work with all other trades. ®a�3ao�ic�ed�a� p ABLp Note: Truss ID's may vary. ®�®O�J� .'... E' r 4# If you have any questions, please do not hesitate to call. Sincerely, F •STD OF E les°°•� 1/18/2021 R.�l• Carl A. Brown, P.E. Luis Pa/I'd°Iis P.E. FL. # 56126 FL. # , 864 FDS Engineering Associates, A TSG Company "Your Building Code Experts" CONNECTORS SCHEDULE ROOF TRUSS Q ID MODEL ROOF UPLIFT SYM 0 11 A-11 LUS24 / JUS24 895 / 836 490 /610 1LA- 10 A HTU261 THD26 3600 / 3470 1555 / 2330 ILA 0 B HTU28 / THD28 4680 / 5040 2140 / 2330 JIB 0 C HTU26-2 / THD26-2 3600 / 3356 2175 / 2340 1Le 0 D HTU28-2 / THD28-2 4680 / 6005 3485 / 2596 ILD 0 E HGUS26-2 / THDH26-2 5320 / 6245 2155 / 2340 1 I LE 0 F HGUS28-2 / THDH28-2 7460 / 8025 1323513330 1 LF 0 G HGUS263 / THDH263 5230/5246 2155 / 2340 1 LG 0 H HGUS28-3 / THDH28-3 7460 / 7836 3235 / 4370 1 IN 0 J THJA26 / HJC26 9100 / 8990 4095 / 4370 1 L 3X8NOP REVIEWED ❑ REVIEWED WITH NOTATIONS ❑ REVISE AND RESUBMIT ❑ NOT REVIEWED (SEE EXPLANATION) Corrections or comments made on equipment submittals or shop drawings during this review do not relieve con- tractor from compliance with requirements of the draw- ings and specifications. This check is only for review of general conformance with the design concept of the project and general compliance with the information given in the contract documents. The contractor is responsible for confirming and corelating all quantities and dimen- sions, selecting fabrication processes and techniques construction, coordinating his work with that of all ec trades and performing his work in a safe and sa manner. FL RIDA DESIGN Date I I V By— Subff tlal Bo, Project No Project Name: Project Eng. VERIFY ALL DIMENSIONS AND CEILING CONDITIONS PRIOR TO APPROVAL SOIX CERIND F NO REOUIRED IN MELD BY BULDER MAIN WIND FORCE RESISTING SYWEwCC NYBRIO WIND ASC6r-10 IMPORTANT ENCLOSED EXPOSURE CATEOORYC OCCUFANCY CATEGORY 0 This Drawing Must Be Approved And WIND LOAD In IWH WIND IMPORTANCE FACTOR 1.W Returned Before Fabrication Will TRUSSES HAVE BEEN DESIGNED FOR A 1110 PSF BOTTOM CHORD LIVE LOAD Begin. For Your Protection Check All NONCONCURRENr Wit ANY OTHER LIVE LC Dimensions And Conditions Prior To APBELO Of Plan. SIGNATURE BELOW INDICATES ALL ROOF LOADING FLOOR LOADING NOTES AND DIMENSIONS HAVE TCLL: 20 PSF TCLL: 40 PSF BEEN ACCEPTED. TCDL: 07 PSF TCDL: 10 PSF BCDL: 10 PSF BCDL- 5 PSF BY TOTAL: 37 PSF TOTAL- 55 PSF DURATION: 1.25 DURATION: 1.00 CAUTIONM DO NOT ATTEMPT TO ERECT TRUSSES WITHOUT REFERRING TO THE ENGINEERING DRAWINGS AND BSCI-B1 SUMMARY SHEETS. ALL PERMANENT BRACING MUST BE IN PLACE PRIOR TO LOADING TRUSSES. (ie. SHEATHING, SHINGLES, ETC.) ALL INTERIOR BEARING WALLS MUST BE IN PLACE PRIOR TO INSTALLING TRUSSES. REFER TO FINAL ENGINEERING SHEETS FOR THE FOLLOWING. 1) NUMBER OF GIRDER PLIES AND NAILING SCHEDULE 2) BEARING BLOCK REQUIREMENTS 3) SCAB DETAILS (IF REQUIRED) 4) UPLIFT AND GRAVITY REACTIONS. WARNING Backcharges Will Not Be Accepted Regardless of Fault Without Prior Notification By Customer Within 48 Hours And Investigation By Builders First Source. NO EXECPTIONS. The General Contractor Is Responsible For All Connections Other Than Truss to Truss, Gable Shear Wall, And Connections. Temporary and Permanent Bracing, And Ceiling And Roof Diaphragm Connections. ROOF PITCH: 6112 CEILING PITCH: 0112 TOP CHORD SIZE: 2 X 4 BOTTOM CHORD SIZE 2 X 4 OVERHANG LENGTH: 16" END CUT: Plumb CANTILEVER: — TRUSS SPACING: 24" BUILDING CODE: FBC2020 BEARING HEIGHT SCHEDULE BUILDER: Adams Homes PROJECT: Single Family MODEL: 1 1820 A 3C FL ADDRESS: 5360 LUGO ST LOT / BLOCK- 2311 SUBDIVISION: WATERSTONE CITY: FT PIERCE DRAWN BY: K SANCHFZ 2697008 DATE: 10110812021 1 SCALE: NTS PLAN DATE: 1 2021 REVISIONS: 1. 2. 3. 4. t• 6'anmom 1 Firs03Oure 4408 Airport Road Plank City, FL 33693 Ph.(813) 305-1300 Fax (813) 305-1301 a Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. RE: 2597008 - LOT 23/1 WATERSTONE M'T k USA 1 e , nc. Site Information: 6904 Parke East Blvd. ampa, FL 33610-4115 Customer Info: Adams Homes Port St Lucie Project Name: 2597008 Model: 1820 Lot/Block: 23/1 Subdivision: WATERSTONE Address: 5360 LUGO STREET,. City: Fort Pierce State: FL Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: State: General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2020/TP12014 Design Program: MiTek 20/20 8.4 Wind Code: N/A Wind Speed: 160 mph Roof Load: 37.0 psf Floor Load: N/A psf This package includes 29 individual, Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet . conforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. Seal# Truss Name Date 1 T22400438 A01 1/11/21 2 T22400439 A01 AG 1/11/21 3 T22400440 A01 BG 1/11/21 4 T22400441 A01 CG 1/11/21 5 T22400442 A02 1/11/21 6 T22400443 A03 1/11/21 7 T22400444 A04 1/11/21 8 T22400445 A05 1/11/21 9 T22400446 A06 1/11/21 10 T22400447 A07 1/11/21 11 T22400448 A08 1/11/21 12 T22400449 B01 G 1/11/21 13 T22400450 B06G 1/11/21 14 T22400451 C 1 1/11/21 15 T22400452 C 1 V 1/11/21 16 T22400453 C3 1/11/21 17 T22400454 C3V 1/11/21 18 T22400455 C5 1/11/21 19 T22400456 C5V 1/11/21 20 T22400457 D01 G 1/11/21 21 T22400458 D02A 1/11/21 22 T22400459 E7 1/11/21 No. Seal# Truss Name Date 23 T22400460 EN 1/11/21 24 T22400461 E7VP 1/11/21 25 T22400462 G01 1/11/21 26 T22400463 G02 1/11/21 27 T22400464 G03 1/11/21 28 T22400465 H7 1/11121 29 T22400466 H7V 1/11/21 The truss drawing(s) referenced above have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by Builders FirstSource (Plant City, FL). Truss Design Engineer's Name: Velez, Joaquin My license renewal date for the state of Florida is February 28, 2023. IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. RECEIVED FEB 12 2020 ST. Luele County, Permitting January 11,2021 Velez, Joaquin 1 of 1 Job Truss Truss Type City Ply LOT 23/1 WATERSTONE 2597008 A01 SPECIAL 13 1 T22400438 Job Reference o tional Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:22:39 2021 Page 1 ID:193QG WBBpX3jR187zeOm7kz5?ad-UbDRXpFKF9ICwh7cyHOFTZEEeL8UD7rDVbm?VJzwzA_ 1-0-0 6-3-0 11-11-12 19-10-0 27-8-4 33-5-0 39-8-0 1-0-0 1-4-0 6-3-0 5-8-12 7-10.4 7-10-4 5-8-12 6-3-0 1-4-0 Scale = 1:71.8 5x6 = 6.00 12 4xb — 4xl0 MT20HS % 3.00 FIT 8-10-8 4xl0 MT20HS ZZ Iv 1N O LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2020/TP12014 CSI. TC 0.91 BC 0.90 WB 0.71 Matrix-MSH DEFL. Vert(LL) Vert(CT) Horz(CT) in (loc) I/defl Ud -0.63 10-11 >759 240 -1.15 10-11 >413 180 0.59 ' 8 n/a n/a PLATES MT20 MT20HS Weight: 197 lb GRIP 244/190 187/143 FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP M 31 'Except" TOP CHORD Structural wood sheathing directly applied. 1-4,6-9: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 5-0-10 oc bracing. BOT CHORD 2x4 SP M 31 'Except' WEBS 1 Row at midpt 6-11, 4-12 13-14,10-13: 2x4 SP No.1 WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 8=0-8-0 Max Horz 2=-433(LC 8) Max Uplift 2=-797(LC 10), 8=-797(LC 10) Max Grav 2=1793(LC 15), 8=1793(LC 16) FORCES. (lb) -Max. Comp./Max. Ten. -All farces 250 (lb) or less except when shown. TOP CHORD 2-3=-5905/2705, 3-4=-5621/2545, 4-5=-2780/1527, 5-6=-2739/1527, 6-7=-5299/2545, 7-8=-5593/2705 BOT CHORD 2-14=-2278/5679, 12-14=-1502/3876, 11-12=-680/2253, 10-11=-1502/3376, 8-10=-2278/5061 WEBS 5-11=-449/1175, 6-11 =-1 486/856, 6-10=-708/2011, 7-10=-260/287, 5-12=-449/1229, 4-12=-1574/856, 4-14=-708/2191, 3-14=-246/287 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 15-10-6, Exterior(2R) 15-10-6 to 23-9-10, Interior(1) 23-9-10 to 37-0-6, Exterior(2E) 37-0-6 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) " his truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Bearing at joint(s) 2, 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 797 lb uplift at joint 2 and 797 lb uplift at joint 8. January 11,2021 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGEMII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not• a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the.overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek'. is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 2311 WATERSTONE T22400439 2597008 A01AG SPECIAL 3 1 Job Reference (optional) _rS 'f5LQULi16c tManr Uuy, rLh Mani Giry, FL - 33567, 8.43U s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:22:41 2021 Page 1 ID:I93QGWBBpX3jRi87zeOm7kz5?ad-R_LCyVGanmZw9?H?3iQjZ JbH9pVhlWWzvF6ZCzwz9y 1 4-0 63-0 11-11-12 19-10-0 26-8-4 32-8-5 39 8-0 14-0 63-0 5-8-12 7-10-4 6-10-4 6-0-1 6-11-11 3x6 % 3.00 12 15-3-8 5x6 = 6.00 12 4x6 II 5 6 4-10-0 13 12 „ ,v 4x6 = 6xl2 MT20HS = 3x6 Scale = 1:72.2 3x6 = LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2020/TPI2014 CSI. TC 0.83 BC 0.99 WB 0.76 Matrix-MSH DEFL. Vert(LL) Vert(CT) Horz(CT) in (loc) I/defl L/d -0.35 10-12 >660 240 -0.56 10-12 >416 180 -0.08 12 n/a n/a PLATES GRIP MT20 244/190 MT20HS 187/143 Weight: 204 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-3-11 oc purlins. BOT CHORD 2x4 SP No.2 "Except" BOT CHORD Rigid ceiling directly applied or 5-6-7 oc bracing. Except: 6-12: 2x4 SP No.3, 9-11: 2x4 SP No.1 1 Row at midpt 6-14 WEBS 2x4 SP No.3 2-2-0 oc bracing: 12-14 WEBS 1 Row at midpt 7-12 REACTIONS. (size) 2=0-8-0, 12=0-4-0, 9=Mechanical Max Horc 2=425(LC 9) Max Uplift 2=-511(LC 10), 12=-586(LC 10), 9=-396(LC 10) Max Grav 2=927(LC 15), 12=1839(LC 15), 9=956(LC 16) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2514/1308, 3-4=-2153/1115, 4-5=-668/628, 5-6=-423/571, 6-7=-196/376, 7-8=-1329/740,8-9=-1507/776 BOT CHORD 2-16=-1079/2582, 15-16=-482/1303, 12-14=-1306/470, 6-14=-1181/469, 10-12=-221/617, 9-10=-570/1292 WEBS 3-16=-380/327, 4-16=-401/1298, 4-15=-1042/645, 7-12=-889/521, 7-10=-272/899, 8-10=-421/377, 5-15=-467/1152 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 15-10-6, Exterior(2R) 15-10-6 to 23-9-10, Interior(1) 23-9-10 to 35-8-6, Exterior(2E) 35-8-6 to 39-8-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) " ,Whis truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = IO.Opsf. 7) Refer to girder(s) for truss to truss connections. 8) Bearing atjoint(s) 2 considers parallel to grain value using ANSI[TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 511 lb uplift at joint 2, 586 lb uplift at joint 12 and 396 lb uplift at joint 9. January 11,2021 ® WARNING - Vedfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE. Design valid for use only with MiTekO connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek� is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPl1 Quality Criteria, OSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type City Ply LOT 23/1 WATERSTONE 2597008 A01BG SPECIAL T22400440 2 1 01 ? Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:22:42 2021 Page 1 ID:193QGWBBpX3jRl87ze0m7kz5?ad-vAva9rHCY4hnn9sBdPxy5BsodZCiQYGgBZ?f5ezwz9x 1-4-0 6 3-0 11-11-12 19-10-0 26-8-4 32-8-5 39$-0 6-3-0 5 8-12 7-10.4 6-10 4 6-0-1 6-11-11 5x8 \\ Scale = 1:74.7 6.00 12 rr O 3x6 :;�: 3.00 12 6-10-0 10 G4 zo 5 1.5x8 STP = 6x8 = 6x8 = 3x6 = LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2020/TPI2014 CSI. TC 0.73 BC 0.80 WB 0.47 Matrix-MSH DEFL. in Vert(LL) -0.31 Vert(CT) -0.49 Horz(CT) 0.08 (loc) I/deft Ud 9-10 >766 240 9-10 >483 180 10 n/a n/a PLATES GRIP MT20 244/190 Weight: 197 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-8-1 oc purlins. BOT CHORD 2x4 SP No.2 'Except* BOT CHORD Rigid ceiling directly applied or 5-3-7 cc bracing. Except: 5-10: 2x4 SP No.3, 9-10,8-9: 2x4 SP No.1 1 Row at midpt 5-11 WEBS 2x4 SP No.3 4-5-0 oc bracing: 10-11 WEBS 1 Row at midpt 4-11, 6-10 REACTIONS. All bearings 0-8-0 except Qt=length) 8=Mechanical, 12=0-4-0. (lb) - Max Horz 2=425(LC 9) Max Uplift All uplift 100 lb or less at joints) except 2=-547(LC 10), 10=-575(LC 10), 8=-424(LC 10) Max Grav All reactions 250 lb or less at joints) except 2=806(LC 15), 10=1681(LC 15), 8=964(LC 16), 12=251(LC 14) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown. TOP CHORD 2-3=-2036/1449, 3-4=-1650/1257, 4-5=-266/415, 5-6=-203/438, 6-7=-1273/770, 7-8=-1498/846 BOT CHORD 2-13=-1206/2141, 12-13=-591/975, 11-12=-591/975, 10-11 =-1 124/422, 5-11=-513/97, 9-10=-295/655, 8-9=-632/1286 WEBS 3-13=-418/324, 4-11=-1128/798, 6-10=-977/564, 6-9=-217/845, 7-9=-424/370, 4-13=-429/1097 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 15-10-6, Exterior(2R) 15-10-6 to 23-9-10, Interior(1) 23-9-10 to 35-8-6, Exterior(2E) 35-8-6 to 39-8-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * jhis truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide WIII fit between the bottom chord and any other members, with BCDL = 10.Opsf. 6) Refer to girder(s) for truss to truss connections. 7) Bearing atjoint(s) 2 considers parallel to grain value using ANSIfTPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 547 lb uplift at joint 2, 575 lb uplift at joint 10 and 424 lb uplift at joint 8. January 11,2021 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTekO connectors. This design is based only upon parameters shown, and is for an individual building component, not ��* a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MOW always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP/f Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 2311 WATERSTONE 2597008 A01 CG GABLE 1 1 T22400441 r Job Reference (optional) v ,a,,, "y, /, 17I0111 . !Ly, rL - oaoor, 6.431.) s Nov 3U 2020 MiTek Industries, Inc. Sat Jan 9 21:22:43 2021 Page 1 I D:193QG WBBpX3jR187zeOm7kz5?ad-N MSyNBIgJOpeOJRNB7SBePPwzyYL9OGpQDkDd4zwz9w r14-Q 5-10-0 13-2-0 19-10-0 26-8-4 32-8-5 39-8 0 14-0 5-10-0 7-4-0 6 8-0 6-104 6-0-1 6-11-11 6x12 MT20HS 11 ,a ,1 ,0 1. -IL 3x4 = 1.5x8 STP = 6x8 = 5x8 = 5x6 = 7-4-0 16-8-0 0-7-0 94-7 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defi Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.95 Vert(LL) -0.30 11-12 >774 240 TCDL 7.0 Lumber DOL 1.25 BC 0.77 Vert(CT) -0.49 11-12 >481 180 BCLL 0.0 Rep Stress Incr YES WB 0.43 Horz(CT) 0.08 12 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-MSH LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD BOT CHORD 2x4 SP No.3 `Except' BOT CHORD 2-15: 2x4 SP No.2 P, 13-14: 2x4 SP No.2, 11-12,10-11: 2x4 SP No.1 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 WEBS REACTIONS. All bearings 13-2-0 except Qt=length) 12=0-8-0, 10=Mechanical. (lb) - Max Horz 2=420(LC 9) Max Uplift All uplift 100 lb or less at joint(s) except 2=-286(LC 10), 12=-227(LC 10), 17=-369(LC 10), 15=-301(LC 10), 10=-436(LC 10) Max Grav All reactions 250 lb or less at joint(s) 16, 18 except 2=268(LC 19), 12=1136(LC 16), 17=361(LC 15), 15=728(LC 15), 10=963(LC 16), 2=268(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-286/343, 4-5=-353/349, 5-6=-236/462, 6-7=-223/466, 7-8=-1351/824, 8-10=-1595/925 BOT CHORD 14-15=-628/366, 5-14=-509/406, 12-13=-519/44, 6-13=-399/60, 11-12=-363/701, 10-11=-736/1417 WEBS 4-17=-376/381, 7-12=-989/577, 7-11=-225/876, 8-11=-484/392 5x8 = 39-8-0 Scale = 1:77.7 PLATES GRIP MT20 244/190 MT20HS 187/143 Weight: 259 lb FT = 20% Structural wood sheathing directly applied. Rigid ceiling directly applied or 6-0-0 oc bracing, Except: 10-0-0 oc bracing: 11-12 6-11-2 oc bracing: 10-11. 1 Row at midpt 6-13 6-0-0 oc bracing: 12-13 1 Row at midpt 7-12 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vuit=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -2-0-0 to 1-11-10, Interior(1) 1-11-10 to 15-10-6, Exterjor(2R) 15-10-6 to 23-9-10, Interior(1) 23-9-10 to 35-6-10, Exterior(2E) 35-6-10 to 39-6-4 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Ggible End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 5) All plates are MT20 plates unless otherwise indicated. 6) At plates are 2x4 MT20 unless otherwiseindicated. 7) Gable studs spaced at 2-0-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = IO.Opsf. January 11.2021 Continued on page 2 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. • Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing is MiTek' always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS17TP11 Quality Criteria, DSB-89 and BCS/ Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 6904 Parke East Blvd. Tampa, FL 36610 Job Truss Truss Type city Ply LOT 23/1 WATERSTONE T22400441 2597008 •. A01 CG GABLE 1 1 i Job Reference (optional) �uc�o n�aw�uwa tridlu �11y, rL/, rianc any, rL - oaoor, 1:5.4JU 5 Nov 3U ZU2U MiTek Industries, Inc. Sat Jan 9 21:22:43 2021 Page 2 I D:193QG WBBpX3jR187ze0m7kz5?ad-NMSyNBIgJOpeOJRNB7SBePPwzyYL90GpQDkDd4zwz9w NOTES- 10) Lumber designated with a "P" is pressure -treated with preservatives. Plate lateral resistance values have been reduced 20% where used in this lumber. Plates should be protected from corrosion per the recommendation of the treatment company. Borate or other suitable treatment may be used if it does not corrode the plates. If ACQ, CBA , or CA-B treated lumber is used, improved corrosion protection is required, and G185 galvanized plates may be used with this design. Incising factors have not been considered for this design. Building designer to verify suitability of this product for its intended use. 11) Refer to girder(s) for truss to truss connections. 12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 286 lb uplift at joint 2, 227 lb uplift at joint 12, 369 lb uplift atjoint 17, 301 lb uplift at joint 15, 436 lb uplift at joint 10 and 286 lb uplift at joint 2. ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5119/2020 BEFORE USE. ' Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with passible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS/fTP/f Quality Criteria, DSB-89 and BCS/ Building Component SafetyInformation available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 6904 Parke East Blvd. Tampa, FL 36610 Truss Type SPECIAL Qty I Ply I LOT 23/1 WATERSTONE T22400442 2597008 0 Builders stSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:22:44 2021 Page 1 I D:193QG WBBpX3jR187ze0m7kz5?ad-rZOKaXIS4hxVOSOakq_QAcx6eMssuOLyftUmAXzwz9v 1 4-0 6-3-0 11-11-12 19-0-0 20 8-0 2741 4 33-5-0 39-8-0 1-0- 1 4-0 6-3-0 5-8-12 7-0 4 1-8-0 7-0 4 5-8-12 6-0-0 1 4-0 5x8 ::�- 3.00 12 5x6 = 6.00 12 5x6 = 3x4 = 19-10-0 31-0-0 5x8 Scale = 1:73.9 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.89 Vert(LL) 0.61 11-12 >787 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.88 Vert(CT) -0.91 11-12 >522 180 MT20HS 187/143 BCLL 0.0 Rep Stress Incr YES WB 0.76 Horz(CT) 0.57 9 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-MSH Weight: 218 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 "Except` TOP CHORD Structural wood sheathing directly applied. 1-4,7-10: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 4-8-1 oc bracing. BOT CHORD 2x4 SP No.2 "Except' 2-16,9-11: 2x4 SP M 31 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 9=0-8-0 Max Horz 2=-417(LC 8) Max Uplift 2=-797(LC 10), 9=-797(LC 10) Max Grav 2=1540(LC 1), 9=1540(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-4905/2784, 3-4=-4621/2623, 4-5=-2726/1752, 5-6=-1932/1439, 6-7=-2726/1752, 7-8=-4621/2623,8-9=-4905/2784 BOT CHORD 2-16=-2350/4717, 15-16=-1549/3216, 13-15=-776/1929, 12-13=-776/1929, 11-12=-1549/3091,9-11=-2351/4431 WEBS 3-16=-282/293, 4-16=-742/1736, 4-15=-1216/792, 5-15=-573/1132, 5-13=-267/321, 6-13=-267/320, 6-12=-573/1068, 7-12=-1137/792, 7-11=-743/1605, 8-11=-296/294 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -14-0 to 2-7-10, Intedor(1) 2-7-10 to 15-0-6, Exterior(2R) 15-0-6 to 24-7-10, Interior(1) 24-7-10 to 37-0-6, Exterior(2E) 37-0-6 to 41-0-0 zone;C-C for members and forces 8, MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer/ Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific tosthe use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Bearing atjoint(s) 2, 9 considers parallel to grain value using ANSIrrPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 797 lb uplift at joint 2 and 797 lb uplift at joint 9. January 11,2021 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not ��• a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication,- storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPlt Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 23/1 WATERSTONE 2597008 A03 SPECIAL 1 1 T22400443 Build— Lire#13— - 1— Job Reference (optional) -- .1, 1 ,a,,, Ly, . I - —.1, 8.430 s Nov 30 202u MiTek Industries, Inc. Sat Jan 9 21:22:46 2021 Page 1 ~ ID:193QGWBBpX3jR187zeOm7kz5?ad-nx85?DKjbJBDFmAysF0uG11 RVAYiMIXF6BZtEPzwz9t 1. _0 6�-0 11-11-12 17-0-0 22 8-0 27-8-5 33-5-0 39 8-0 1-0- 1�-0 6-3-0 5-8-12 5-0-5 5-8-0 5-04 5$-12 6-3-0 1�4-0 6.00 12 5x6 = 5x8 = 4x10 MT20HS � 3.00 12 4x10 MT20HS ZZ 8-8-0 8-8-0 Scale = 1:75.4 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2020/TPI2014 CSI. TC 0.91 BC 0.86 WB 0.71 Matrix-MSH DEFL. Vert(LL) Vert(CT) Horz(CT) in (loc) I/defl L/d -0.62 11-12 >769 240 -1.12 11-12 >423 180 0.60 9 n/a n/a PLATES MT20 MT20HS Weight: 202 lb GRIP 2441190 187/143 FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 *Except* TOP CHORD Structural wood sheathing directly applied. 1-4,7-10: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 4-8-15 oc bracing. BOT CHORD 2x4 SP M 31 'Except' WEBS 1 Row at midpt 4-14, 6-14, 7-12 13-15,11-13: 2x4 SP No.1 WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 9=0-8-0 Max Horz 2=376(LC 9) Max Uplift 2=-797(LC 10), 9=-797(LC 10) Max Grav 2=1799(LC 15), 9=1801(LC 16) FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-5904/2977, 3-4=-5589/2795, 4-5=-2863/1738, 5-6=-2546/1644, 6-7=-2773/1738, 7-8=-5320/2795, 8-9=-5644/2977 BOT CHORD 2-15=-2526/5637, 14-15=-1660/3794, 12-14=-1034/2565, 11-12=-1660/3367, 9-11 =-2526/51 10 WEBS 3-15=-294/324, 4-15=-797/2189, 4-14=-1428/799, 5-14=-420/998, 6-14=-251/253, 6-12=-420/1108, 7-12=-1355/799, 7-11=-797/2035, 8-11=-306/324 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 13-0-6, Exterior(2R) 13-0-6 to 26-7-10, Interior(1) 26-7-10 to 37-0-6, Exterior(2E) 37-0-6 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) A..W plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 8) Bearing atjoint(s) 2, 9 considers parallel to grain value using ANSl1TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 797 lb uplift at joint 2 and 797 lb uplift at joint 9. January 11,2021 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not �s a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the - fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type City Ply LOT 2311 WATERSTONE T22400444 2597008 A04 SPECIAL 1 1 1 , Job Reference (optional) Builders Firstsource (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:22:47 2021 Page 1 I D:193QG WBBpX3jRl87zeOm7kz5?ad-F8iTCYLLMcJ4tw18QzX7oFZesatc5oZPLdQmrzwz9s 1-4-0 5-11-1 9-6-9 15-0-0 19-10-0 24-8-0 W-1-7 W-8-15 39-8-0 1-0- 1-4-0 5-11-1 3-7-9 5-5-7 4-10-0 4-10-0 5-5-7 3=7-9 5-11-1 1-4-0 Scale = 1:73.4 6.00 12 5x6 = 3x4 = 5x6 = 25 6 26 7 28 1.5x8 STP = 4x12 :�— 3.00 12 4x12 zZ 3x8 MT20HS \\ 3x8 MT20HS // 5-8-0 15-0-0 24-8-0 31-0-0 39-8-0 8-8-0 6-4-0 9-8-0 6-4-0 8-8-0 Plate Offsets (X,Y)-- [2:0-1-15,1-2-15], [2:0-2-14,Edge], [4:0-3-0,0-3-0], [5:0-3-0,0-2-0], [7:0-3-0,0-2-0], [8:0-3-0,0-3-0], [10:0-1-15,1-2-15], [10:0-2-14,Edge], [12:0-7-0,0-3-8], f16:0-7-0,0-3-81 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.83 Vert(LL) -0.67 13-15 >715 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.95 Vert(CT) -1.16 13-15 >410 180 MT20HS 187/143 BCLL 0.0 Rep Stress Incr YES WB 0.53 Horz(CT) 0.60 10 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-MSH Weight: 204 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing, Except: WEBS 2x4 SP No.3 5-3-0 oc bracing: 13-15. WEDGE WEBS 1 Row at midpt 4-15, 8-13 Left: 2x4 SP No.3, Right: 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 10=0-8-0 Max Horz 2=-335(LC 8) Max Uplift 2=-797(LC 10), 10=-797(LC 10) Max Grav 2=1804(LC 15), 10=1804(LC 16) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-5834/3030, 3-4=-5622/2947, 4-5=-3283/1933, 5-6=-2934/1832, 6-7=-2836/1832, 7-8=-3175/1933,8-9=-5371/2947,9-10=-5595/3030 BOT CHORD 2-16=-2565/5553, 15-16=-2182/4748, 13-15=-1410/3054, 12-13=-2182/4303, 10-12=-2565/5077 WEBS 4-16=-610/1626, 4-1 5=-1 922/1023, 5-15=-527/1184, 7-13=-527/1190, 8-13=-1814/1023, 8-12=-610/1514, 6-15=-339/205, 6-13=-339/205 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 11-0-6, Exterior(2R) 11-0-6 to 18-11-10, Interior(1) 18-11-10 to 20-8-6, Exterior(2R) 20-8-6 to 28-7-10, Interior(1) 28-7-10 to 37-0-6, Exterior(2E) 37-0-6 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 8) Bearing at joint(s) 2, 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 797 lb uplift at joint 2 and 797 lb uplift at joint 10. January 11,2021 ----...__.._._._... WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. -- ......... ---- --- -- -- Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with passible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS/?PN Quality Criteria, DSB-89 and BCS/ Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 6904 Parke East Blvd. Tampa, FL 36610 Job Truss Truss Type City Ply LOT 23/1 WATERSTONE 2597008 A05 SPECIAL 1 1 T22400445 R, dtdnr¢ Pimtq ,,,e rcroi=nt r;«, n o�.,... ,-:... Job Reference o tional --'--'-' "- --- 30 2020 MiTek Industries, Inc. Sat Jan 9 21:22:48 2021 Page 1 ID:193QGWBBpX3jR187zeOm7kz5?ad jKGrQuMz7wRxV4KLzg2MLS6nezD?gAcYaUS_Jlzwz9r 1 4-0 6 8-0 13-0-0 19-10-0 26-8-0 33-M 39-8-0 1-0- 111-0 6 8-0 611-0 6-10-0 6-10-0 64-0 6-8-0 1-4-0 Scale = 1:73.4 5x8 = 6.00 12 3x4 = 5x8 = 4 23 24 5 25 266 5x8 = 3.00 FIT 5x8 ZZ 15-7-5 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2020/TP12014 CSI. TC 0.95 BC 0.94 WB 0.80 Matrix-MSH DEFL. Vert(L.L) Vert(CT) Horz(CT) in (loc) I/deft Ud 0.62 10-11 >762 240 -0.96 11-13 >498 180 0.59 8 n/a n/a PLATES MT20 MT20HS Weight: 190 lb GRIP 244/190 187/143 FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP M 31 'Except' TOP CHORD Structural wood sheathing directly applied. 4-6: 2x4 SP No.2, 1-3,7-9: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. BOT CHORD 2x4 SP M 31 "Except' 12-14,10-12: 2x4 SP No.2 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 REACTIONS. (size) 2=0-B-0, 8=0-8-0 Max Horz 2=-294(LC 8) Max Uplift 2=-797(LC 10), 8=-797(LC 10) Max Grav 2=1540(LC 1), 8=1540(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-4919/3101, 3-4=-4613/2924, 4-5=-3036/2083, 5-6=-3036/2083, 6-7=-4613/2924, 7-8=-4919/3101 BOT CHORD 2-14=-2640/4556, 13-14=-1511/2821, 11-13=-1772/3223, 10-11=-1511/2821, 8-10=-2640/4445 WEBS 3-14=-371/397, 4-14=-1038/1926, 4-13=-149/535, 5-13=-399/275, 5-11=-399/275, 6-11=-149/535, 6-10=-1038/1815, 7-10=-378/397 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 9-0-6, Exterior(2R) 9-0-6 to 16-11-10, Interior(1) 16-11-10 to 22-8-6, Exterior(2R) 22-8-6 to 30-7-10, Interior(1) 30-7-10 to 37-0-6, Exterior(2E) 37-0-6 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific too.the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) '.This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Bearing at joint(s) 2, 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 797 lb uplift at joint 2 and 797 lb uplift at joint 8. January 11,2021 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not• a truss system. Before use, the building designer must vedfy the applicability of design parameters and properly incorporate this design into the overall p /� building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.. Additional temporary and permanent bracing iTe k� is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the IV � fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS/1rPl1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type City Ply LOT 23/1 WATERSTONE 2597008 A06 SPECIAL 1 1 T22400446 a-awos Fi�stS a roi� 4 r; r, Job Reference (optional) 24 25 2x4 11 5x6 = - •• ��• • •� •• n 11, ant „y, - oaoor, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:22:49 2021 Page 1 ID:193QG WBBpX3jRl87zeOm7kz5?ad-CWgDdEMbuEZo6EuXXOZbtgMNd FZhghoBBXrkzwz9q 1-4-0 5-11-1 11-0-0 17-0-0 22-8-0 28-8-0 33-8-15 39-8-0 1-0- 1 4-0 5-11-1 5-0-15 6-0-0 5-8-0 6-0-0 5_0 5-11-1 1 0 5x6 = 6.00 12 5x6 = 26 27 7 1.5x8 STP = 5x8 3.00 12 5x8 -0-0 8-2-1 Scale = 1:72.0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip IDOL 1.25 TC 0.93 Vert(LL) 0.73 12-14 >656 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.68 Vert(CT) -1.03 14-15 >464 180 MT20HS 187/143 BCLL 0.0 Rep Stress Incr YES WB 0.56 Horz(CT) 0.58 9 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-MSH Weight: 209 Ib FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.1 "Except` TOP CHORD Structural wood sheathing directly applied. 4-6,6-7: 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 4-7-6 oc bracing. BOT CHORD 2x4 SP M 31 "'Except' 13-15,11-13: 2x6 SP No.2 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 9=0-8-0 Max Horz 2=-253(LC 8) Max Uplift 2=-797(LC 10), 9=-797(LC 10) Max Grav 2=1540(LC 1), 9=1540(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-4917/3105, 3-4=-4608/2845, 4-5=-4142/2674, 5-6=-4142/2674, 6-7=-4145/2676, 7-8=-4608/2844, 8-9=-4916/3104 BOT CHORD 2-15=-2648/4483, 14-15=-1790/3279, 12-14=-2246/4158, 11-12=-1791/3281, 9-11=-2647/4442 WEBS 3-15=-333/385, 4-15=-745/1516, 4-14=-511/1116, 5-14=-321/300, 6-12=-381/301, 7-12=-511/1117, 7-11=-742/1461, 8-11=-342/385 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 7-0-6, Exterior(2R) 7-0-6 to 14-11-10, Interior(1) 14-11-10 to 24-8-6, Exterior(2R) 24-8-6 to 32-7-10, Interior(1) 32-7-10 to 37-0-6, Exterior(2E) 37-0-6 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific tcathe use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) `.This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Bearing atjoint(s) 2, 9 considers parallel to grain value using ANSI/fPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 797 lb uplift at joint 2 and 797 lb uplift at joint 9. January 11,2021 ®WARNING - Vedfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not�� a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.. Additional temporary and permanent bracing M1Tek• is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI1rP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 23/1WATERSTONE T22400447 2597008 A07 SPECIAL 1 1 ' Builders Firsts ,,me /Ofen� _ .._ Job Reference (optional) ..... ........ ...... .. __ __ ___ . _ jl•'••`-"•" ••"•" `- •"• `�v�/. ��+7, - +``. 6. 0 J rvuv Ju 2uzu Nii 1 eK I11UU5[ne5, inc. .oat Jan `J LI:22:50 202i rage 1 I D:193QG WBBpX3jRl87zeOm7kz5?ad-gjOcraNDfXhfkNTj554gQtB9gn?Kl7Qrl ox5NAzwz9p r1 4-0, 4 6-5 9-0-0 15-10 8 23-9-8 30-8-0 35-1-11 39-8-0 Al-0-Q 1'-0' 4 6-5 4-5-11 r 6-10-8 7-10-15 6-10-8 4-5-11 4 6-5 1-4-0 Scale = 1:72.0 5x6 = 3x4 = 5x8 = 5x6 = 6.00 12 4 27 2829 5 6 3031 32 7 i 3x4 i 3x4 1.5x8 STP = 3 26 833 N 25 ZS 9 34 1.5x8 STP = 2 17 16 15 14 13 12 0 0 Yf 1 5x6 = 9 10 °' N 0 18 3x4 = 3x6 = 3x4 = 5x6 = 11 I 2x4 11 3x4 = 2x4 II 3x6 3.00 12 3x6 ZZ 6-5 8-8-0 12 8-0 12-t�-14 19-10-0 26-0-0 1419 31-0-0 35-1-11 39 S-0 4 6-5 4-1-11 4-0-0 0-0-14 7-1-2 6-2-0 5-0-0 4-1-11 4-6--5 Plate Offsets (X,Y)-- [2:0-0-10,Edge], [4:0-3-0,0-2-0], [6:0-4-0,0-3-0] [7:0-3-0 0-2-0] [9:0-0-10 Edge] LOADING (psf) SPACING- 2-0-0 CSI. DEFL, in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.78 Vert(LL) 0.21 15-16 >745 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.50 Vert(CT) 0.17 15-16 >942 180 BCLL 0.0 Rep Stress Incr NO WB 0.59 HOrz(CT) 0.03 9 n/a n/a BCDL. 10.0 Code FBC2020/TPl2014 Matrix-MSH Weight: 187 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-7-5 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2x4 SP No.3 REACTIONS. All bearings 0-8-0 except Qt=length) 16=0-4-0, 13=0-4-0. (lb) - Max Horz 2=212(LC 9) Max Uplift All uplift 100 lb or Jess at joint(s) except 2=-288(LC 10), 9=-302(LC 10), 16=-686(LC 10), 13=-715(LC 10) Max Grav All reactions 250 lb or less at joints) except 2=451(LC 15), 9=527(LC 16), 16=1125(LC 19), 13=1185(LC 20) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-947/494, 3-4=-338/135, 4-5=-325/669, 5-6=-58/715, 6-7=-348/707, 7-8=-471/221, 8-9=-1083/570 BOT CHORD 2-18=-291/979, 17-18=-295/986, 16-17=-23/293, 15-16=-328/181, 13-15=-426/296, 12-13=0/332, 11-12=-365/945, 9-11 =-359/937 WEBS 3-17=-599/468, 4-17=-51/419, 4-16=-986/630, 5-16=-792/685, 5-15=-520/206, 6-15=-489/297, 7-12=-72/391, 8-12=-588/458, 6-13=-773/671, 7-13=-997/703 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 5-0-6, Exterior(2R) 5-0-6 to 12-11-10, Interior(1) 12-11-10 to 26-8-6, Exterior(2R) 26-8-6 to 34-7-10, Interior(1) 34-7-10 to 37-0-6, Exterior(2E) 37-0-6 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) T?Ris truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 2, 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify rapacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 288 lb uplift at joint 2, 302 lb uplift at joint 9, 686 lb uplift at joint 16 and 715 lb uplift at joint 13. 9) Load case(s) 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 15, 16, 17, 18 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard Except: ;ontinued on page 2 January 11.2021 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.• Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is for �f� T T1 IViM�lek' always required stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the I� fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSifrPN Quality Criteria, DSB-89 and BCSi Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 6904 Parke East Blvd. Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 23/1 WATERSTONE T22400447 2597008 A07 SPECIAL 1 1 Job Reference (optional) nunaers Firsiaource triant City, rL/, rlanr uty, rl.-:Jzlbbf, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:22:50 2021 Page 2 ID:193QG W BBpX3jR187zeOm7kz5?ad-gjOcraNDfXhtkNTj554gQtBggn?Kl7Qr1 ox5NAzwz9p LOAD CASE(S) Standard Except: 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=-54, 4-7=-54, 7-10=-54, 17-19=-20, 12-17=-20, 12-22=-20 4) Dead + 0.6 C-C Wind (Pos. Internal) Case 1: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=105, 2-25=59, 25-26=47, 4-26=70, 4-28=70, 28-31=47, 7-31=70, 7-33=70, 33-34=47, 9-34=59, 9-10=105, 17-19=-10, 16-17=-10, 13-16=20(F=30), 12-13=-10, 12-22=-10 Horz: 1-2=-113, 2-25=-67, 25-26=-56, 4-26=-78, 7-33=78, 33-34=56, 9-34=67, 9-10=113 5) Dead + 0.6 C-C Wind (Neg. Internal) Case 1: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=3, 2-4=-41, 4-7=-41, 7-9=-41, 9-10=3, 17-19=-20, 16-17=-20, 13-16=10(F=30), 12-13=-20, 12-22=-20 Horz: 1-2=-17, 2-4=27, 7-9=-27, 9-10=17 6) Dead + 0.6 MWFRS Wind (Pos. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=42, 2-4=13, 4-29=45, 29-32=26, 7-32=16, 7-9=31, 9-10=21, 17-19=-10, 16-17=-10, 13-16=20(F=30), 12-13=-10, 12-22=-10 Horz: 1-2=-50; 2-4=-22, 7-9=39, 9-10=29 7) Dead + 0.6 MWFRS Wind (Pos. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=21, 2-4=31, 4-27=16, 27-30=26, 7-30=45, 7-9=13, 9-10=42, 17-19=-10, 16-17=-10, 13-16=20(F=30), 12-13=-10, 12-22=-10 Horz: 1-2=-29, 2-4=-39, 7-9=22, 9-10=50 8) Dead + 0.6 MWFRS Wind (Neg. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-26, 2-4=-36, 4-7=-16, 7-9=5, 9-10=15, 17-19=-20, 16-17=-20, 13-16=10(F=30), 12-13=-20, 12-22=-20 Horz: 1-2=12, 2-4=22, 7-9=19, 9-10=29 9) Dead + 0.6 MWFRS Wind (Neg. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=15, 2-4=5, 4-7=-16, 7-9=-36, 9-10=-26, 17-19=-20, 16-17=-20, 13-16=10(F=30), 12-13=-20, 12-22=-20 Horz: 1-2=-29, 2-4=-19, 7-9=-22, 9-10=-12 10) Dead + 0.6 MWFRS Wind (Pos. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=74, 2-4=45, 4-7=45, 7-9=45, 9-10=74, 17-19=-10, 16-17=-10, 13-16=20(F=30), 12-13=-10, 12-22=-10 Horz: 1-2=-82, 2-4=-54, 7-9=54, 9-10=82 11) Dead + 0.6 MWFRS Wind (Pos. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=45, 2-4=16, 4-7=16, 7-9=16, 9-10=45, 17-19=-10, 16-17=-10, 13-16=20(F=30), 12-13=-10, 12-22=-10 Horz: 1-2=-53, 2-4=-25, 7-9=25, 9-10=53 12) Dead + 0.6 MWFRS Wind (Neg. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-5, 2-4=-16, 4-7=-16, 7-9=-16, 9-10=-5, 17-19=-20, 16-17=-20, 13-16=10(F=30), 12-13=-20, 12-22=-20 Horz: 1-2=-9, 2-4=2, 7-9=-2, 9-10=9 13) Dead + 0.6 MWFRS Wind (Neg. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-5, 2-4=-16, 4-7=-16, 7-9=-16, 9-10=-5, 17-19=-20, 16-17=-20, 13-16=10(F=30), 12-13=-20, 12-22=-20 Horz: 1-2=-9, 2-4=2, 7-9=-2, 9-10=9 15) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) Left): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-53, 2-4=-61, 4-7=-45, 7-9=-30, 9-10=-22, 17-19=-20, 16-17=-20, 13-16=61(F=81), 12-13=-20, 12-22=-20 Horz: 1-2=9, 2-4=17, 7-9=14, 9-10=22 16) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) Right): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-22, 2-4=-30, 4-7=-45, 7-9=-61, 9-10=-53, 17-19=-20, 16-17=-20, 13-16=61(F=81), 12-13=-20, 12-22=-20 Horz: 1-2=-22, 2-4=-14, 7-9=-17, 9-10=-9 17) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) 1 st Parallel): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-37, 2-4=-45, 4-7=-45, 7-9=-45, 9-10=-37, 17-19=-20, 16-17=-20, 13-16=61(F=81), 12-13=-20, 12-22=-20 Horz: 1-2=-7, 2-4=1, 7-9=-1, 9-10=7 18) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) 2nd Parallel): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-37, 24=45, 4-7=-45, 7-9=-45, 9-10=-37, 17-19=-20, 16-17=-20, 13-16=61(F=81), 12-13=-20, 12-22=-20 Horz: 1-2=-7, 2-4=1, 7-9=-1, 9-10=7 WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall building design. Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 23/1 WATERSTONE 2597008 A08 SPECIAL 1 1 T22400448 o I �; Job Reference (optional) A u. mars rs ource t ,ant aty, n), Plant i.ny, rL - 0000r, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:22:52 2021 Page 1 ID:193QG W BBpX3jR187zeOm7kz5?ad-c5VMGG PTB9xMzhd6CW71 VI GVcbbZmyH8V6QBS3zwz9n 1 4-0 7-0-0 12-3-1 16-0-8 19-10-0 22-5-14 26-3-5 3210 39 8-0 1-0- 1 4-0 7-0-0 5: - 3-9-8 3-9-8 2-7-14 3-9-8 6.4-11 7-0-0 1�-0 Scale = 1:72.0 5x6 = 6.00 12 3x8 = 3x4 = 2x4 II 5x6 = 5x12 = 5x6 — 3 24 25 4 2627 28 5 29 30 6 31 7 32 833 34 35 9 1.5x8 STP = Z2 N 37 38 39 40 15 14 41 42 43 44 45 46120 �1.5x82 mlR Sx836 5x12 = 11 Io 6x8 = 3x6 = 6x8 = 3x8 = 3x6 3.00 FIT 3x6 Zz 7-1-8 12-3-1 12 -0 19-10-0 26-2-0 26 -5 32-6-8 39-8-0 7-1-8 5-1-9 0- -15 7 4-0 6�-0 0- -5 6-3-3 7-1-8 Plate Offsets (X,Y)-- [2:0-0-10,Edge],'[3:0-3-0,0-2-0], [4:0-3-8,0-1-8], [7:0-3-0,0-3-0], [8:0-3-8,0-2-8], [9:0-4-0,0-2-8], [10:0-0-10,Edge], [12:0-8-0,0-0-8], [13:0-3-8,0-3-0], r16:0-3-8,0-3-01 r17:0-5-4 0-0-81 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.83 Vert(LL) 0.24 14-16 >696 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.90 Vert(CT) -0.27 14-16 >630 180 BCLL 0.0 Rep Stress Incr NO WB 0.95 Horz(CT) 0.06 10 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-MSH Weight: 177 lb FT = 20% LUMBER - TOP CHORD 2x4 SP N0.2 *Except* 7-9: 2x4 SP No.1 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-10-9 oc purlins. BOT CHORD Rigid ceiling directly applied or 5-5-4 oc bracing. WEBS 1 Row atmidpt 8-12 REACTIONS. All bearings 0-8-0 except (jt=length) 16=0-4-0, 13=0-4-0. (lb) - Max Horz 2=-171(LC 6) Max Uplift All uplift 100 lb or less atjoint(s) except 2=-356(LC 8), 10=-429(LC 8), 16=-1695(LC 8), 13=-1859(LC 8) Max Grav All reactions 250 lb or less atjoint(s) except 2=612(LC 1), 10=697(LC 1), 16=2263(LC 1), 13=2397(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1245/434, 3-4=-1038/444, 4-5=-573/923, 5-6=-856/1302, 6-7=-856/1302, 7-8=-866/1022, 8-9=-1360/708,'9-10=-1598/729 BOT CHORD 2-17=-263/1089, 16-17=-923/751, 14-16=-529/321, 13-14=-435/248, 12-13=-1022/891, 10-12=-507/1412 WEBS 3-17=-102/288, 4-16=-1311/939, 5-16=-1398/1438, 5-14=-602/680, 6-14=-421/437, 7-14=-775/753, 7-13=-1427/1490, 8-13=-1441/1137, 9-12=-14/366, 4-17=-1017/2098, 8-12=-1419/2494 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 2, 10 considers parallel to grain value using ANSUTPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 356 lb uplift at joint 2, 429 lb uplift at joint 10, 1695 lb uplift at joint 16 and 1859 lb uplift at joint 13. 9) Load case(s) 4, 5, 6, 7, 8, 9, 10, 11, 13, 14, 15, 16 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. .lanuary 11 gn91 :ontinued on page 2 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. • Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with passible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11rP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 2311 WATERSTONE T22400448 2597008 A08 SPECIAL 1 1 Job Reference (optional) ,uuuers nrstoource [clan[ Uny. rul, mant ury, rL - 30obf, 8.43U s Nov 30 202U MiTek Industries, Inc. Sat Jan 9 21:22:52 2021 Page 2 NOTES- ID:193QG WBBpX3jR187zeOm7kz5lad-c5VMGGPTB9xMzhd6CW 71VI GVcbbZmyH8V6QBS3zwz9n 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 175 lb down and 159 lb up at 7-0-0, 111 lb down and 197 lb up at 9-0-12, 111 lb down and 197 lb up at 11-0-12, 111 lb down and 197 lb up at 13-0-12, 111 lb down and 197 lb up at 15-0-12, 111 lb down and 197 lb up at 17-0-12, 111 lb down and 197 lb up at 19-0-12, 111 lb down and 197 lb up at 20-7-4, 111 lb down and 197 lb up at 22-7-4, 111 Ito down and 197 lb up at 24-7-4, 111 lb down and 197 lb up at 26-7-4, 111 lb down and 197 Ito up at 28-7-4, and 111 lb down and 197 lb up at 30-7-4, and 175 lb down and 356 lb up at 32-8-0 on top chord, and 353 lb down and 128 lb up at 7-1-8, 92 lb down at 9-0-12, 92 lb down at 11-0-12, 92 lb down at 13-0-12, 92 lb down at 15-0-12, 92 lb down at 17-0-12, 92 lb down at 19-0-12, 92 lb down at 20-7-4, 92 lb down at 22-7-4, 92 lb down at 24-7-4, 92 lb down at 26-7-4, 92 lb down at 28-7-4, and 92 lb down at 30-7-4, and 353 lb down and 128 lb up at 32-6-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-9=-54, 9-11=-54, 17-18=-20, 12-17=-20, 12-21=-20 Concentrated Loads (lb) Vert: 3=-175(B) 7=-111(B) 9=-175(B) 17=-330(B) 15=-46(B) 12=-330(B) 24=-111(B) 25=-111(B) 26=-111(B) 28=-111(B) 29=-111(B) 30=-111(13) 31=-111(B) 32=-111(B) 33=-111(B)34=-111(B) 35=-111(B)36=-46(B) 37=-46(B) 38=-46(B) 39=-46(B) 40=-46(B) 41=-46(B) 42=-46(B)43=-46(B) 44=-46(B) 45=-46(B) 46=-46(B) 4) Dead + 0.6 MWFRS Wind (Pos. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=42, 23=13, 3-27=45, 27-34=26, 9-34=16, 9-10=31, 10-11=21, 17-18=-10, 16-17=-10, 13-16=49(F=59), 12-13=-10, 12-21=-10 Horz: 1-2=-50, 2-3=-22, 9-10=39, 10-11=29 Concentrated Loads (lb) Vert: 3=130(B) 7=156(B) 9=257(B) 17=108(B) 15=-23(B) 12=108(B) 24=136(B) 25=136(B) 26=136(B) 28=156(B) 29=156(B) 30=156(B) 31=156(B) 32=156(B) 33=156(B) 34=156(B) 35=165(B)36=-23(B) 37=-23(B) 38=-23(B) 39=-23(B) 40=-23(B) 41=-23(B) 42=-23(B)43=-23(B) 44=-23(B) 45=-23(B) 46=-23(B) 5) Dead + 0.6 MWFRS Wind (Pos. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=21, 2-3=31, 3-25=16. 8-25=26, 8-9=45, 9-10=13, 10-11=42, 17-18=-10, 16-17=-10, 13-16=49(F=59), 12-13=-10, 12-21=-10 Horz: 1-2=-29, 2-3=-39, 9-10=22, 10-11=50 Concentrated Loads (lb) Vert: 3=159(B) 7=156(B) 9=246(B) 17=108(B) 15=-23(B) 12=108(B) 24=165(B) 25=156(B) 26=156(B) 28=156(B) 29=156(B) 30=156(B) 31=156(B) 32=156(B) 33=136(13)34=136(B) 35=1 36(B) 36=-23(B) 37=-23(B)38=-23(B) 39=-23(B) 40=-23(B) 41=-23(B) 42=-23(B)43=-23(B) 44=-23(B) 45=-23(B) 46=-23(B) 6) Dead + 0.6 MWFRS Wind (Neg. Internal) Left: Lumber Increase=1.60,,Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-26, 2-3=-36, 3-9=-16, 9-10=5, 10-11=15, 17-18=-20, 16-17=-20, 13-16=39(F=59), 12-13=-20, 12-21=-20 Horz: 1-2=12, 2-3=22, 9-10=19, 10-11=29 Concentrated Loads (lb) Vert: 3=54(B) 7=197(B) 9=315(B) 17=128(B) 15=-13(B) 12=128(B) 24=197(B) 25=197(B) 26=197(B) 28=197(B) 29=197(B) 30=197(B) 31=197(B) 32=197(B) 33=197(B) 34=197(B) 35=197(B) 36=-13(B) 37=-13(B)38=-13(B) 39=-13(B) 40=-13(B) 41=-13(B)42=-13(B) 43=-13(B) 44=-13(B) 45=-13(B) 46=-13(B) 7) Dead + 0.6 MWFRS Wind (Neg. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=15, 2-3=5, 3-9=-16, 9-10=-36, 10-11=-26, 17-18=-20, 16-17=-20, 13-16=39(F=59), 12-13=-20, 12-21=-20 Horz: 1-2=-29, 2-3=-19, 9-10=-22, 10-11=-12 Concentrated Loads (lb) Vert: 3=54(B)7=197(B)9=356(B)17=128(B)15=-13(B)12=128(B)24=197(B)25=197(B)26=197(B)28=197(B)29=197(B)30=197(B)31=197(B)32=197(B) 33=197(B) 34=197(B) 35=197(B) 36=-13(B) 37=-13(6) 38=-13(B) 39=-13(B) 40=-13(B) 41=-13(B) 42=-13(B) 43=-13(B) 44=-13(B) 45=-13(B) 46=-13(B) 8) Dead + 0.6 MWFRS Wind (Pos. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=74, 2-3=45, 3-9=45, 9-10=45, 10-1 1=74,17-18=-10, 16-17=-10, 13-16=49(F=59), 12-13=-10, 12-21=-10 Horz: 1-2=-82, 2-3=-54, 9-10=54, 10-11=82 Concentrated Loads (lb) Vert: 3=130(B)7=136(B)9=214(B)17=108(B)15=-23(B)12=108(B)24=136(B)25=136(B)26=136(B)28=136(B)29=136(B) 30=136(B) 31=136(B) 32=136(B) 33=136(B) 34=136(B) 35=136(B) 36=-23(B) 37=-23(B) 38=-23(B) 39=-23(B) 40=-23(B) 41=-23(B) 42=-23(B) 43=-23(B) 44=-23(B) 45=-23(B) 46=-23(B) 9) Dead + 0.6 MWFRS Wind (Pos. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=45, 2-3=16, 3-9=16, 9-10=16, 10-1 1=45,17-18=-10, 16-17=-10, 13-16=49(F=59), 12-13=-10, 12-21=-10 Horz: 1-2=-53, 2-3=-25, 9-10=25, 10-11=53 Concentrated Loads (lb) Vert: 3=116(B) 7=165(B) 9=271(B) 17=108(B) 15=-23(B) 12=108(B) 24=165(B) 25=165(B) 26=165(B) 28=165(B) 29=165(B) 30=165(B) 31=165(B) 32=165(B) 33=165(B) 34=165(B) 35=165(B) 36=-23(B) 37=-23(B) 38=-23(B) 39=-23(B) 40=-23(B) 41=-23(B) 42=-23(B) 43=-23(B)44=-23(B) 45=-23(B) 46=-23(B) 10) Dead + 0.6 MWFRS Wind (Neg. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-5, 2-3=-16, 3-9=-16, 9-10=-16, 10-11=-5, 17-18=-20, 16-17=-20, 13-16=39(F=59), 12-13=-20, 12-21=-20 Horz: 1-2=-9, 2-3=2, 9-10=-2, 10-11=9 Concentrated Loads (lb) Vert: 3=72(B) 7=197(B) 9=335(B) 17=128(B) 15=-13(B) 12=128(B) 24=197(B) 25=197(B) 26=197(B) 28=197(B) 29=197(B) 30=197(B) 31=197(B) 32=197(B) 33=197(B) 34=197(B) 35=197(B) 36=-13(B) 37=-13(B) 38=-13(B) 39=-13(B) 40=-13(B) 41=-13(B) 42=-13(B) 43=-13(B)44=-13(B) 45=-13(B) 46=-13(B) 11) Dead + 0.6 MWFRS Wind (Neg. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-5, 2-3=-16, 3-9=-16, 9-10=-16, 10-11=-5, 17-18=-20, 16-17=-20, 13-16=39(F=59), 12-13=-20, 12-21=-20 Horz: 1-2=-9, 2-3=2, 9-10=-2, 10-11=9 Continued on page 3 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. ' Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verily the applicability of design parameters and properly Incorporate this design Into the overall � /� T8k• building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing �� 1 Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 23/1 WATERSTONE 2597008 r A08 SPECIAL 1 1 T22400448 Job Reference (optional) -�••-•^ �- o.vou 5 nov ju zuzu Nu I eK tnaustnes, Inc. sat Jan a 21:22:52 2021 Page 3 I D:193QG WBBpX3jR187zeOm7kz5?ad-c5VMGG PTB9xMzhd6CW7IVIGVcbbZmyH8V6QBS3zwz9n LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 3=72(B) 7=197(B) 9=335(B) 17=128(B) 15=-13(B) 12=128(B) 24=197(B) 25=197(B) 26=197(B) 28=197(B) 29=197(B) 30=197(B) 31=197(B) 32=197(B) 33=197(6) 34=197(13) 35=197(B)36=-13(13) 37=-13(B) 38=-13(B) 39=-13(B) 40=-13(13) 41=-13(B) 42=-13(B) 43=-13(B) 44=-13(B) 45=-13(B) 46=-13(B) 13) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) Left): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-53, 2-3=-61, 3-9=-45, 9-10=-30, 10-11=-22, 17-18=-20, 16-17=-20, 13-16=24(F=44), 12-13=-20, 12-21=-20 Horz: 1-2=9, 2-3=17, 9-10=14, 10-11=22 Concentrated Loads (lb) Vert: 3=-19(B)7=145(B)9=232(B)17=76(B)15=-13(B)12=76(B)24=145(B)25=145(B)26=145(B)28=145(B)29=145(B)30=145(B)31=145(B)32=145(B) 33=145(B) 34=145(B) 35=145(B)36=-13(B) 37=-13(B) 38=-13(B)39=-13(B) 40=-13(B) 41=-13(B) 42=-13(B) 43=-13(B) 44=-13(B) 45=-13(B) 46=-13(B) 14) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) Right): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-22, 2-3=-30, 3-9=-45, 9-10=-61, 10-11=-53, 17-18=-20, 16-17=-20, 13-16=24(F=44), 12-13=-20, 12-21=-20 Horz: 1-2=-22, 2-3=-14, 9-10=-17, 10-11=-9 Concentrated Loads (lb) Vert: 3=-19(B) 7=145(B) 9=262(B) 17=76(B) 15=-13(B) 12=76(B) 24=145(B) 25=145(B) 26=145(B) 28=145(B) 29=145(B) 30=145(B) 31=145(B) 32=145(B) 33=145(B)34=145(B) 35=145(B)36=-13(B) 37=-13(B) 38=-13(B) 39=-13(B) 40=-13(B)41=-13(B) 42=-13(B)43=-13(B) 44=-13(B) 45=-13(B)46=-13(B) 15) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) 1st Parallel): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-37, 2-3=-45, 3-9=-45, 9-10=45, 10-11=-37, 17-18=-20, 16-17=-20, 13-16=24(F=44), 12-13=-20, 12-21=-20 Horz: 1-2=-7, 2-3=1, 9-10=-1, 10-11=7 Concentrated Loads (lb) Vert:3=-5(B) 7=145(B)9=247(B)17=76(B)15=-13(B)12=76(B)24=145(B)25=145(B)26=145(B)28=145(6)29=145(B)30=145(B)31=145(B)32=145(B) 33=145(B)34=145(B) 35=145(B) 36=-13(B) 37=-13(B) 38=-13(B)39=-13(B) 40=-13(B) 41=-13(B) 42=-13(B)43=-13(B) 44=-13(B) 45=-13(B) 46=-13(B) 16) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) 2nd Parallel): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-37, 2-3=-45, 3-9=-45, 9-10=-45, 10-11=-37, 17-18=-20, 16-17=-20, 13-16=24(F=44), 12-13=-20, 12-21=-20 Horz: 1-2=-7, 2-3=1, 9-10=-1, 10-11=7 Concentrated Loads (lb) Vert: 3=-5(B)7=145(B)9=247(B)17=76(B)15=-13(B)12=76(B)24=145(B)25=145(B)26=145(B)28=145(B)29=145(B)30=145(B)31=145(B)32=145(B) 33=1 45(B) 34=1 45(B) 35=145(B) 36=-13(13) 37=-13(B)38=-13(B) 39=-13(B) 40=-13(B) 41=-13(13)42=-13(B)43=-13(13) 44=-13(B) 45=-13(B) 46=-13(B) ® WARNING - Vedfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5/19/2020 BEFORE USE, T Design valid for use only with MiTekO connectors. This design is based only upon parameters shown, and Is for an individual building component, not• a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek� is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/17P11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type City Ply LOT 23/1 WATERSTONE T22400449 2597008 � 801G SPECIAL 1 1 Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:22:53 2021 Page 1 I D:193QGW BBpX3jR187zeOm7kz5?ad-4I3kTcP6yS3DbrClmDeX2 Wpfg_vLVOHHjm91_Vzwz9m 1 4-0 8 6-0 11-10-0 19-6-0 27-8-0 1 4-0 8-6-0 3 4-0 7-8-0 8-2-0 4x6 = y Jx4 — 1.5x8 STP = 6x8 = 6x8 = 7-10-0 8-0-0 17-6-5 1 27-8-0 Scale = 1:56.8 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2020/TPI2014 CSI. TC 0.84 BC 0.99 WB 0.97 Matrix-MSH DEFL. Vert(LL) Vert(CT) Horz(CT) in (loc) I/deft L/d 0.34 10-13 >283 240 -0.42 7-8 >566 180 -0.03 8 n/a n/a PLATES GRIP MT20 244/190 Weight: 132 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-8-5 oc purlins. BOT CHORD 2x4 SP No.1 'Except" BOT'CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 2-10: 2x4 SP No.2, 3-8: 2x4 SP No.3 7-11-9 oc bracing: 6-7. WEBS 2x4 SP No.3 2-2-0 oc bracing: 8-10 WEBS 1 Row at midpt 4-8 REACTIONS. (size) 2=0-4-0, 8=0-8-0, 6=Mechanical Max Horz 2=306(LC 9) Max Uplift 2=-434(LC 10), 8=-579(LC 10), 6=-365(LC 10) Max Grav 2=397(LC 21), 8=1135(LC 2), 6=973(LC 16) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-405/228, 34=-309/399, 4-5=-1355/804, 5-6=-1473/759 BOT CHORD 8-10=-479/674, 3-10=-424/457, 7-8=-9/340, 6-7=-543/1254 WEBS 4-8=-573/251, 4-7=-518/1159, 5-7=-542/542 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 7-10-6, Exterior(2R) 7-10-6 to 15-9-10, Interior(1) 15-9-10 to 23-8-6, Exterior(2E) 23-8-6 to 27-8-0 zone; cantilever left exposed ; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 434 lb uplift atjoint 2, 579 lb uplift at jo+1t 8 and 365 lb uplift at joint 6. January 11,2021 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 6/19/2020 BEFORE USE. ° Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MOW always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection andbracingof trusses and truss systems, see ANS11TP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 2311 WATERSTONE T22400450 2597008 B06G GABLE 1 1 Job Reference (optional) ..,,r, - 0.40U s rvov aU cUGU Ivu.l eK mausines, Inc. Jat Jan U ZI:ZZ:b4 ZU21 Page 1 I D:193QGWBBpX3jRl87zeOm7kz5?ad-YUd6gyQkjmB4D?nVKx9maj MoROIQE_vRyQvl Wxzwz9l 1 4-0 8-6-0 11-10-0 19.6-0 27-8-0 1.4-0 8-6-0 3 4-0 7-8-0 8-2-0 5x8 II 2x4 11 8 2x4 11 6.00 12 2x4 11 7 9 2x4 11 6 10 2x4 11 34 2x4 11 5 5 11 2x4 11 5x8 3x4 '- 4 12 33 3 3x8 I I 24 2 3x12 MT2 S 11 X 26 1 8-0-8 23 22 0 7 3x8 I 5x8 = 2x4 11 4x10 MT20HS = 2x4 I I Scale=1:56.4 35 3x6 13 N Iv 0 0 3�0L, 19 18 17 16 15 5x8 = 1.5x8 5TP = 2x4 11 2x4 11 2x4 11 2x4 11 7x10 = 20-0-0 - 8-0-0 0-0-8 9-5-13 ' 10-1-11 Plate Offsets (X,Y)-- [2:0-4-0,0-3-1], [12:0-4-0 0-3-0] [14:0-4-0 0-3-1] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.93 Vert(LL) 0.27 15-32 >858 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.81 Vert(CT) -0.44 15-32 >532 180 MT20HS 187/143 BCLL 0.0 Rep Stress Incr YES WB 0.43 Horz(CT) 0.06 14 n/a n/a BCDL 10.0 Code FBC2020rrP12014 Matrix-MSH Weight: 186 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2x4 SP No.3 JOINTS 1 Brace at Jt(s): 24, 25, 26 OTHERS 2x4 SP No.3 REACTIONS. (size) 2=0-3-8, 20=0-8-0, 14=Mechanical Max Horz 2=299(LC 9) Max Uplift 2=-466(LC 10), 20=-627(LC 10), 14=-340(LC 10) Max Grav 2=346(LC 19), 20=1138(LC 1), 14=759(LC 16) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-227/258, 4-5=-215/251, 5-6=-212/274, 6-7=-199/324, 7-8=-172/309, 8-9=-963/839, 9r10=-993/789,10-11=-953/728,11-12=-1058/728,12-14=-1170/724 BOT CHORD 20-21=-521/706, 6-21=-389/505, 14-15=-530/1015 WEBS 20-24=-696/278, 8-24=-772/318, 8-25=-592/902, 25-26=-591/899, 15-26=-570/890, 12-15=-554/444 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -2-0-0 to 1-11-10, Intedor(1) 1-11-10 to 7-8-14, Exterior(2R) 7-8-14 to 15-10-0, Interior(1) 15-10-0 to 23-6-14, Exterior(2E) 23-6-14 to 27-6-8 zone; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSIrrPI 1. 4) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 5) All plates are MT20 plates unless otherwise indicated. 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Refer to girder(s) for truss to truss connections. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 466 lb uplift at joint 2, 627 lb uplift at joint 20 and 340 lb uplift at joint 14. January 11,2021 ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 6/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not ��• a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MOW always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPl1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 23/1 WATERSTONE T22400451 2597008 C1 JACK 4 1 Job Reference (optional) Buuaers FirsiSource (Plan[ City, ra), Plant City, PL - 33b6/, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:22:54 2021 Page 1 I D:3xt?Yd6RbYnXO16Sf6ghjjz4cnz-YUd6gyQkjmB4D?nVKx9majMzSOUNE4dRyQvl WXZWZ91 -1-4-0 0-11-4 1-4-0 0-11-4 Plate Offsets (X,Y)- LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Lid TCLL 20.0 Plate Grip DOL 1.25 TC 0.23 Vert(LL) 0.00 5 >999 240 TCDL 7,0 Lumber DOL 1.25 BC 0.04 Vert(CT) 0.00 5 >999 180 BCLL 0,0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 4 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=79(LC 10) Max Uplift 3=-3(LC 1), 2=-195(LC 10), 4=-15(LC 1) Max Grav 3=20(LC 10), 2=159(LC 15), 4=44(LC 10) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Scale = 1:7.6 PLATES GRIP MT20 244/190 Weight: 5 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 0-11-4 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1:60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 3 lb uplift at joint 3, 195 lb uplift at joint 2 and 15 lb uplift at joint 4. January 11,2021 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. • Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is for MiTek always required stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 6904 Parke East Blvd. Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 2311 WATERSTONE T22400452 2597008 C1V SPECIAL 4 1 � � Job Reference o tional (Plant crry, FL), Plant City, PL - ssbtir, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:22:55 2021 Page 1 I D:193QG W BBpX3jR187zeOm7kz5?ad-OgBVuIRMU4Jxg9Mhueg?7xu8CogezXtaB4er3Ozwz9k -1-4-0 0-11-4 1-4-0 0-11.4 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud TCLL 20.0 Plate Grip DOL 1.25 TC ' 0.23 Vert(LL) 0.00 7 >999 240 TCDL 7.0 Lumber DOL 1.25 BC 0.04 Vert(CT) 0.00 7 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 HOrz(CT) 0.00 2 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix -MP LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD BOT CHORD 2x4 SP No.2 BOT CHORD REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=79(LC 10) Max Uplift 3=-4(LC 1), 2=-181(LC 10), 4=-14(LC 1) Max Grav 3=16(LC 10), 2=158(LC 1), 4=35(LC 10) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Scale = 1:7.6 PLATES GRIP MT20 244/190 Weight: 5 lb FT = 20% Structural wood sheathing directly applied or 0-11-4 oc puffins. Rigid ceiling directly applied or 6-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second.gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 4 lb uplift at joint 3, 181 lb uplift at joint 2 and 14 lb uplift at joint 4. January 11,2021 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE. • Design valid for use only with Mi7ek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek� Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI17P1f Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type City Ply LOT 23/1 WATERSTONE T22400453 2597008 C3 JACK 4 1 Job Reference (optional) Builders rirstaource triant ctry, V Q, Cant City, FL - 33561, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:22:56 2021 Page 1 I D:3xt?Yd6RbYnXO16Sf6 ghjjz4cnz-U tlt5dS_FNSoS IxtRM B Ef8RJyC8ji_7j PkO Pbgzwz9j 2-11-4 M 2-11-4 Scale = 1:12.7 Plate Offsets (X,Y)-- [2:0-4-0,0-0-4] 2-11-4 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Well L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.23 Vert(LL) -0.01 4-7 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.11 Vert(CT) -0.01 4-7 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix -MP Weight: 12 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-11-4 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=132(LC 10) Max Uplift 3=-52(LC 10), 2=-157(LC 10) Max Grav 3=72(LC 15), 2=197(LC 15), 4=49(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 52 lb uplift at joint 3 and 157 lb uplift at joint 2. January 11,2021 -- ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek� is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 23/1 WATERSTONE T22400454 2597008 C3V SPECIAL q 1 Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567. 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:22:56 2021 Page 1 I D:193QG WBBpX3jR187zeOm7kz5?ad-Utlt5dS_FNSoSIxtRMBEf8RJyC8hi_7jPkOPbgzwz9j 1 4-0 2-11-4 1-4-0 2-11-4 Scale = 1:12.7 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.23 Vert(LL) -0.01 4-7 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.12 Vert(CT) -0.01 4-7 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix -MP Weight: 12 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD BOT CHORD 2x4 SP No.2 BOT CHORD REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=132(LC 10) Max Uplift 3=-57(LC 10), 2=-149(LC 10) Max Grav 3=74(LC 15), 2=196(LC 15), 4=49(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Structural wood sheathing directly applied or 2-11-4 oc purlins. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASIDE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Bearing at joint(s) 2 considers parallel to grain value using ANSIrrPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 57 lb uplift at joint 3 and 149 lb uplift at joint 2. ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 511912020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Qualify Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 January 11,2021 MiTek' 6904 Parke East Blvd. Tampa, FL 36610 ob Truss Truss Type City Ply LOT 23/1 WATERSTONE T2240045: 597008 C5 JACK q 1 c Job Reference o tional Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:22:57 2021 Page 1 1 1 3x4 = w:axi r T cbKo rnxulb5ttign/jz4cnz-z3JFJzScOhaf4S W373jTCM_P7cPcRRMteO7y7Gzwzgi 4-11-4 4-11-4 d_11-A Scale=1:17.6 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.52 Vert(LL) 0.06 4-7 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.39 Vert(CT) -0.06 4-7 >908 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TPl2014 Matrix -MP Weight: 18 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-11-4 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=185(LC 10) Max Uplift 3=-107(LC 10), 2=-167(LC 10) Max Grav 3=134(LC 15), 2=267(LC 15), 4=87(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a jive load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 107 lb uplift at joint 3 and 167 lb uplift at joint 2. January 11,2021 ® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not• a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing 11 A'Te1�' Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MV 1 R fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP/1 Quality Criterla, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, M6904 Parke East Blvd. Tampa, Parke East D 2060136610 Job Truss Truss Type Qty Ply LOT 2311 WATERSTONE T22400456 2597008 C5V SPECIAL 4 1 ' Job Reference (optional) Buuaers Firsi,ource (Plant City, FL), Plant city, FL - 3356f, -1-4-0 3x9 � 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:22:57 2021 Page 1 ID:193QG WBBpX3jR187zeOm7kz5?ad-z3JFJzScOhaf4S W3?3jTCM_PWCPuRRMteO7y7Gzwz9i Scale = 1:17.6 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.56 Vert(LL) 0.06 4-7 >925 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.44 Vert(CT) -0.07 4-7 >875 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.01 3 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix -MP Weight: 18 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD BOT CHORD 2x4 SP No.2 BOT CHORD REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=185(LC 10) Max Uplift 3=-112(LC 10), 2=-161(LC 10) Max Grav 3=136(LC 15), 2=265(LC 15), 4=87(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Structural wood sheathing directly applied or 4-11-4 oc purlins. Rigid ceiling directly applied or 6-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 112 lb uplift atjoint 3 and 161 lb uplift at joint 2. January 11,2021 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. • Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing Is for MiTek always required stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 6904 Parke East Blvd. Tampa, FL 36610 Job Truss Truss Type City Ply LOT 23/1 WATERSTONE 2597008 D01G COMMON 2 1 T22400457 � Job Reference (optional) 3 �•��� �� �,.y, �, aF K ..Iy, 11- ooaor, 5.43U s NOV 3U ZUZU MiTek Industries, Inc. Sat Jan 9 21:22:58 2021 Page 1 I D:193QG WBBpX3jR187zeOm7kz5?ad-RFsdWJTEn?i Whc4GZmEiIZWbU?dVAr5Ot2tWflzwz9h 5-8-6 10-0-0 14-3-10 20-0-0 21-0-0 5-8-6 4-3-10 4-3-10 5-8-6 1.4-0 4x6 = 3x6 = 5x8 = 3x6 = Scale = 1:35.8 Plate Offsets (X,Y)-- [1:0-6-0,0-0-2][5:0-2-12 0-1-8j [7:0-4-0 0-3-4] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.48 Vert(LL) -0.16 7-10 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.93 Vert(CT) -0.35 7-10 >686 180 BCLL 0.0 Rep Stress Incr YES WB 0.23 Horz(CT) 0.03 5 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-MSH Weight: 87 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-8-3 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 2-2-0cc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 1=Mechanical, 5=0-8-0 Max Horz 1=-224(LC 8) Max Uplift 1=-348(LC 10), 5=-454(LC 10) Max Grav 1=738(LC 1), 5=814(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1223/1006, 2-3=-935/780, 3-4=-934/777, 4-5=-1217/986 BOT CHORD 1-7=-715/1133, 5-7=-686/1061 WEBS 3-7=-402/592, 4-7=-408/437, 2-7=-417/471 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-0-0 to 3-11-10, Interior(1) 3-11-10 to 6-0-6, Extedor(2R) 6-0-6 to 13-11-10, Interior(1) 13-11-10 to 17-4-6, Exterior(2E) 17-4-6 to 21-4-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 348 lb uplift atjoint 1 and 454 lb uplift at joint 5. Iv 0 January 11,2021 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not, a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M iTek� Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP/1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 23/1 WATERSTONE 2597008 s � D02A GABLE 1 1 T22400458 r=rrc�e.�u PI t C FL Job Reference (optional) rce ( an tty, ), Plant Clty, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:22:59 2021 Page 1 I D:193QG WBBpX3jR187zeOm7kz5?ad-vRQ?kfUsYlgNJmfS7UIxHn3m 1 PAivKIA6ic3C9zwz9g -1-4-0 10-0-0 20-0-0 21-4-0 1 4-0 10-0-0 10-0-0 1 4-0 Scale = 1:39.7 4x6 = Iv 3 Jx4 2x4 11 2x4 11 2x4 II oxb 2x4 II 2x4 11 2x4 11 dace urrsers (A,y)-- 12:U-3-8 togej 12:0-2-8 Edge] r12:0-3-8 Edgel [12.0-2-8 Edge], r17.0-3-0 0-3-0] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.50 Vert(LL) -0.02 13 n/r 180 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.10 Vert(CT) -0.02 13 n/r 120 BCLL 0.0 Rep Stress Incr YES WB 0.07 Horz(CT) 0.01 12 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-SH Weight: 105 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.2 P BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. OTHERS 2x4 SP No.3 REACTIONS. All bearings 20-0-0 (lb) - Max Horz 2=-232(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 18, 20, 16, 14 except 2=-258(LC 10), 12=-258(LC 10), 19=-104(LC 10), 15=-104(LC 10) Max Grav All reactions 250 lb or less at joints) 17, 18, 19, 16, 15 except 2=265(LC 19), 12=265(LC 20), 20=261(LC 15), 14=268(LC 16) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 6-7=-61/302, 7-8=-58/302 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=2ft; Cat. Ii; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Comer(3E) -2-0-0 to 1-11-10, Exterior(2N) 1-11-10 to 6-0-0, Corner(3R) 6-0-0 to 14-0-0, Extedor(2N) 14-0-0 to 18-0-6, Comer(3E) 18-0-6 to 22-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSIfrPI 1. 4) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Lumber designated with a "P" is pressure -treated with preservatives. Plate lateral resistance values have been reduced 20% where used in this lumber. Plates should be protected from corrosion per the recommendation of the treatment company. Borate or other suitable treatment may be used if it does not corrode the plates. If ACQ, CBA, or CA-B treated lumber is used, improved corrosion protection is required, and G185 galvanized plates may be used with this design. Incising factors have not been considered for this design. Building designer to verify suitability of this product for its intended use. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 18, 20, 16, 14 except Qt=lb) 2=258, 12=258, 19=104, 15=104. January 11,2021 ,A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 5119/2020 BEFORE rev. USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not�� a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing Is always required for stability and to MiTek prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS17rP/1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 6904 Parke e East East Blvd. Tampa, 36610 Job Truss Truss Type Qty Ply LOT 2311 WATERSTONE T22400459 2597008 E7 JACK 4 1 Job Reference (optional) �uuaers rtrstaource (Plant City, FL), Plant uity, rL - 33bbl, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:23:00 2021 Page 1 ID:3xt?Yd6RbYnX016Sf6ghj z4cnz-Ne_Ox?VVIcyExwEegBGAq_cggpLaeo6JKMMckbzwzgf 1 4-0 7-0-0 1 4-0 7-0-0 3x6 = 7-M 7-0-0 Scale = 1:23.1 Plate Offsets (X,Y)-- [2:0-0-4,Edge) LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.94 Vert(LL) 0.22 4-7 >381 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.82 Vert(CT) -0.23 4-7 >368 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.01 3 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix -MP Weight: 24 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.1 TOP CHORD Structural wood sheathing directly applied. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 7-7-14 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=241(LC 10) Max Uplift 3=-162(LC 10), 2=-184(LC 10) Max Grav 3=198(LC 15), 2=343(LC 15), 4=124(LC 3) \ FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf, h=15ft; B=45ft; L=40ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 3=162,2=184. January 11,2021 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. ' Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MOW always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/rPll Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type City Ply LOT 23/1 WATERSTONE 2597008 i E7V SPECIAL 7 1 T22400460 RI lilrtorc Fircl.Cn„rrc lDl�n/ r`i h, FI � PI Job Reference (optional) R ant Clty, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:23:00 2021 Page 1 ID:193QG WBBpX3jR187zeOm7kz5?ad-Ne_Ox?VVIcyExwEegBGAq_cpzpKieo6JKM Mckbzwz9f -1-4-0 7-0-0 1 4-0 7-0-0 3x6 LOADING (psf) SPACING- 2-0-0 TCLL 201.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2020frP12014 LUMBER - TOP CHORD 2x4 SP No.1 BOT CHORD 2x4 SP No.2 Scale = 1:22.9 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TC 1.00 Vert(LL) 0.23 4-7 >354 240 MT20 244/190 BC 0.88 Vert(CT) -0.23 4-7 >356 180 WB 0.00 Horz(CT) -0.03 3 n/a n/a Matrix -MP Weight: 25 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 4-9-5 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=241(LC 10) Max Uplift 3=-166(LC 10), 2=-179(LC 10) Max Grav 3=200(LC 15), 2=341(LC 15), 4=124(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1:60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Bearing atjoint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 3=166,2=179. January 11,2021 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not ��• a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MOW always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPl1 Qualify Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. SafetyInformation available from Truss Plate Institute, 2670. Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job 2597008 , f Builders FirstSource Truss E7VP City, FL), Plant City, -1-4-C 41 0 2 E Truss Type SPECIAL Qty I Ply 1 I LOT 23/1 T22400461 - "oor, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:23:01 2021 Page 1 ID:3xt?Yd6RbYnX016Sf6ghjjz4cnz-rgYm8LW73w45Y4prEvnPMC81 CDhFNFMTZ05AG 1 zwz9e 7-0.0 3x6 LOADING (psi) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d TCLL 20.0 Plate Grip DO 1.25 TC 0.77 Vert(LL) 0.21 4-7 >387 240 TCDL 7.0 Lumber DOL 1.25 BC 0.79 Vert(CT) 0.19 4-7 >436 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.01 3 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix -MP LUMBER- BRACING - TOP CHORD 2x4 SP No.1 TOP CHORD BOT CHORD 2x6 SP No.2 BOT CHORD REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=308(LC 10) Max Uplift 3=-153(LC 10), 2=-307(LC 10), 4=-150(LC 10) Max Grav 3=157(LC 15), 2=336(LC 1), 4=140(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Scale = 1:22.6 PLATES GRIP MT20 2441190 Weight: 31 lb FT = 20% Structural wood sheathing directly applied or 4-11-3 oc purlins. Rigid ceiling directly applied or 6-0-1 oc bracing. NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Bearing at joint(s) 2 considers parallel to grain value using ANSIfrPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 3=153, 2=307, 4=150. A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5119/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/t Quality Criteria, DSB-69 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 January 11,2021 MR, MiTek' 6904 Parke East Blvd. Tampa, FL 36610 Job Truss Truss Type city Ply LOT 23/1 WATERSTONE T22400462 2597008 G01 Hip Girder 1 1 Job Reference (optional) Quilders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:23:02 2021 Page 1 ID:3xt?Yd6RbYnXO16Sf6ghjjz4cnzJO68Mh WlgDCyAD01 oclevPhGad?p6fOcogrjoUzwz9d -1-4-0 3�-14 7-0-0 10-0-0 13-0-0 16-7-2 20-0-0 21�-0 14-0 3-4-14 3-7-2 3-0-0 3-0-0 3-7-2 213-14 1-4-0 Scale = 1:36.9 4x6 = 3x4 = 5 4x6 = Io i 4x6 = 3x8 = 4x6 = 3x8 = 4x6 = 7-0-0 13-0-0 20-0-0 7-0-0 6-0-0 7-0-0 LOADING (psQ SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.54 Vert(LL) 0.16 10-12 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.90 Vert(CT) -0.21 10-18 >999 180 BCLL 0.0 Rep Stress Incr NO WB 0.21 Horz(CT) 0.08 8 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-MSH Weight: 101 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-0-13 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 4-11-3 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 8=0-8-0 Max Horz 2=171(LC 7) Max Uplift 2=-909(LC 8), 8=-909(LC 8) Max Grav 2=1851(LC 13), 8=1851(LC 14) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3449/1701, 3-4=-3213/1615, 4-5=-2875/1496, 5-6=-2875/1496, 6-7=-3213/1615, 7-8=-3450/1701 BOT CHORD 2-12=-1391/3184, 10-12=-1392/3066, 8-10=-1391/3057 WEBS 3-12=-290/155, 4-12=-101/564, 5-12=-327/271, 5-10=-327/271, 6-10=-101/563, 7-10=-291 /155 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) except Ot=lb) 2=909, 8=909. 8) Girder carries hip end with 7-0-0 end setback. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 605 lb down and 376 lb up at 13-0-0, and 605 lb down and 376 lb up at 7-0-0 on top chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=-54, 4-6=-112(F=-58), 6-9=-54, 13-16=42(F=-22) Concentrated Loads (lb) Vert: 4=-347(F) 6=-347(F) January 11,2021 WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19f2020 BEFORE USE. -- Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and propedy incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP/f Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 23/1 WATERSTONE T22400463 2597908 t G02 Hip 1 1 Job Reference (optional) Putiaers rirstjource (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:23:03 2021 Page 1 I D:3xt?Yd6RbYnXO16Sf6ghjjz4cnz-nDg WZ1 XNbXKooNzDLKptSdESPOOer6JIOKaHLWZWz9c 4-6-9 9-0-0 11-0-0 15-5-7 20-0-0 4.6-9 4-5-7 2-0-0 4-5-6 4-6-9 Scale = 1:35.9 4x6 = 4x6 = 1I 3x6 = 3z4 = 4x6 = 3x4 = 3x6 = Io 9-0-0 2-0-0 9-0-0 Plate Offsets (X,Y)-- [1:0-6-0,0-0-21, [6:0-2-12,0-1-8) LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.47 Vert(LL) -0.14 9-12 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.67 Vert(CT) -0.29 9-12 >817 180 BCLL 0.0 Rep Stress Incr YES WB 0.23 Horz(CT) 0.03 6 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-MSH Weight: 91 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-9-13 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6.3-5 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 1=078-0, 6=0-8-0 Max Horz 1=-185(LC 8) Max Uplift 1=-352(LC 10), 6=-352(LC 10) Max Grav 1=740(LC 1), 6=740(LC 1) FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-129411062, 2-3=-994/793, 3-4=-838/785, 4-5=-994/793, 5-6=-1294/1062 BOT CHORD 1-9=-861/1197, 7-9=-447/838, 6-7=-861/1147 WEBS 2-9=-437/462, 3-9=-149/287, 4-7=-149/287, 5-7=-438/462 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-0-0 to 3-11-10, Exterior(21R) 3-11-10 to 16-0-6, Exterior(2E) 16-0-6 to 20-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=352, 6=352. January 11,2021 ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFOREUSE. -- Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not ��• a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is for MITek' always required stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11rPl1 Quality Criteria, DSB-09 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 6904 Parke East Blvd. Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 23/1 WATERSTONE 2597008 G03 Hip Girder 1 T22400464 r � Job Reference (optional) —err ru5LQU1J oe tridnt City. rL/, rtanl City, rl_ - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:23:04 2021 Page 1 ID:3xt?Yd6RbYnX016Sf6ghjjz4cnz-FPEunMY?MfSfPXYQV 1 L6_gmcgQn5aN5vF_KgtMzwz9b 10-3-0 4-8.13 9-9-0 1 -0 0 15-3-3 20-0-0 4-8-13 5-0-3 o 5-0-3 4-8-13 0-3-0 ` 4x6 11 Scale = 1:37.7 Io 4x10 MT20HS = 5x6 = 10x12 = 4x12 II 1.5x8 STP = 4x12 I 1.5x8 STP = 5x6 — 10-3-0 4-8.13 9.9-0 1 -0 0 15-3-3 20-0-0 4-9-13 5-D-3 3- 5-0.3 4-8.13 0-3-0 Plate Offsets (X,Y)-- [1:0-2-4,0-0-3], r5:0-3-0 0-2-13] LOADING (pso SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.57 Vert(LL) 0.19 6-7 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.47 Vert(CT) -0.26 6-7 >911 180 MT20HS 187/143 BCLL 0.0 Rep Stress Incr NO WB 0.96 Horz(CT) 0.07 5 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-MSH Weight: 218 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-7-0 oc purlins. BOT CHORD 2x6 SP M 26 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 1=0-8-0, 5=0-8-0 Max Horz 1=-202(LC 6) Max Uplift 1=-2244(LC 8), 5=-2282(LC 8) Max Grav 1=5042(LC 13), 5=5131(LC 14) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-9545/4275, 2-3=-6504/2973, 3-4=-6506/2973, 4-5=-10067/4504 BOT CHORD 1-9=-3758/8664, 7-9=-3758/8664, 6-7=-3962/8979, 5-6=-3962/8979 WEBS 2-9=-937/2337, 2-7=-3055/1412, 4-7=-3567/1635, 4-6=-1130/2778, 3-7=-2367/5406 NOTES- 1) 2-ply truss to be connected together with 10d (0.131 "x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-970 oc. Bottom chords connected as -follows: 2x6 - 2 rows staggered at 0-9=O oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 5) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 6) All plates are MT20 plates unless otherwise indicated. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) " this truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) except Qt=lb) 1=2244, 5=2282. 10) Manger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 805 lb down and 352 lb up at 1-4-0, 805 lb down and 352 lb up at 3-4-0, 882 lb down and 385 lb up at 5-4-0, 949 lb down and 415 lb up at 7-4-0, 946 lb down and 413 lb up at 9-4-0, 946 lb down and 413 lb up at 11-4-0, 946 lb down and 413 lb up at 13-4-0, 719 lb down and 314 lb up at 15-4-0, and 847 lb down and 370 lb up at 16-0-0, and 904 lb down and 395 lb up at 18-0-0 on bottom chord. The design%selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1— � 4 4 7r174 continued on page 2 u,y' ® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 6/1912020 BEFORE USE. Design valid for use only with MiTek@ connectors. This design is based only upon parameters shown, and is for an individual building component, not• a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• Is always required for stabitity and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the . fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI1rPl1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, M6904 Parke East Blvd. D 20601 Tampa, Parke 36610 East Job Truss Truss Type Qty Ply LOT 23/1 WATERSTONE T22400464 2597008 .} G03 Hip Girder 1 n L Job Reference (optional) pwioers rirstaource (rtant city, t-L1, runt city, rL - 3Jt)bf, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:23:04 2021 Page 2 I D:3xt?Yd6RbYnX016Sf6ghjjz4cnz-FPEunMY?MfSfPXYQV 1 L6_gmcgQn5aN5vF_KgtMzwz9b LOAD CASE(S) Standard 1) Dead +Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-5=-54, 1-5=-20 Concentrated Loads (lb) Vert: 6=-660(F) 14=-739(F) 15=-739(F)16=-809(F) 17=-871(F) 18=-868(F) 19=-868(F) 20=-868(F) 21=-777(F) 22=-829(F) ® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5119/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MOW always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11rP/f Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 23/1 WATERSTONE 2597008 ■ H7 MONO TRUSS 2 1 T22400465 Job Reference (optional) 2 - •�• • �'•r, ' 8.430 s Nov su 2uzu Mi I ek Industries, Inc. Sat Jan 9 21:23:05 2021 Page 1 I D:3xt?Yd6RbYnX016Sf6ghjjz4cnz-kboG_iZd78a W 1 h7cTIsLX2JIzg3zJzG2U e3NPpzwz9a -1-101-10-1100 4-6-7 -9-10-1 4-6-7 5-3-10 3X4 = `.^" " F Scale = 1:22.6 4-6-7 4-6-7 9-10-1 5-3-10 Plate Offsets (X,Y)-- [2:0-2-4 0-0-0] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.66 Vert(LL) --0.07 6-7 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.74 Vert(CT) -0.15 6-7 >788 180 BCLL 0.0 Rep Stress Incr NO WB 0.39 Horz(CT) 0.01 5 n/a n/a BCDL 10.0 Code FBC2020[TP12014 Matrix-MSH Weight: 43 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD BOT CHORD 2x4 SP N0.2 BOT CHORD WEBS 2x4 SP No.3 REACTIONS. (size) 4=Mechanical, 2=0-8-0, 5=Mechanical Max Horz 2=240(LC 8) Max Uplift 4=-166(LC 8), 2=-226(LC 8), 5=-78(LC 8) Max Grav 4=159(LC 1), 2=443(LC 1), 5=300(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-734/233 BOT CHORD 2-7=-330/681, 6-7=-330/681 WEBS 3-7=0/322, 3-6=-719/349 Structural wood sheathing directly applied or 6-0-0 oc purlins. Rigid ceiling directly applied or 9-8-5 oc bracing. NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5 except Qt=lb) 4=166,2=226. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 56 lb down and 62 lb up at 1-5-12, 56 lb down and 62 lb up at 1-5-12, 5 lb down and 68 lb up at 4-3-11, 5 lb down and 68 lb up at 4-3-11, and 50 lb down and 138 lb up at 7-1-10, and 50 lb down and 138 lb up at 7-1-10 on top chord, and 22 lb up at 1-5-12, 22 lb up at 1-5-12, 11 lb down an'd 7 lb up at 4-3-11, 11 lb down and 7lb up at 4-3-11, and 51 lb down at 7-1-10, and 51 lb down at 7-1-10 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASES) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=-54, 5-8=-20 inued on page 2 January 11,2021 WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not ��• a truss system. Before use, the building designer must verily the applicability of design parameters and properly incorporate this design into the overall Welk' building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek� Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/rP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. SafetyInformation available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 23/1 WATERSTONE 2597 008� H7 MONO TRUSS T22400465 � � 2 1 Builders FirstSource (Plant city FI plant ca„ PI -111a7 Job Reference o tional ou au -, en muubrrles, Inc. oai Jan u z1:zJ:Ub zUZI Page 2 I D:3xt?Yd6RbYnX016Sf6ghjjz4cnz-kboG_iZd78a W 1 h7cTIsLX2JIzg3zJzG2Ue3NPpzwz9a LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 3=36(F=18, B=18)7=-11(F=-5,B=-5)11=46(F=23,B=23)12=-99(F=-50,B=-50)13=22(F=11,B=11)14=-51(F=-25,B=-25) ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component; truss a ss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MOW always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS/1TP/1 Quality Criteria, DSB-89 and BCSI Building Component e East Blvd. Tampa, Parke 3 East Safety Information avail6904 Park able from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Job Truss Truss Type City Ply LOT 23/1 WATERSTONE 2597008 � � a H7V SPECIAL 2 1 T22400466 Job Reference (optional) I „SwOU CG trim n . ity, ri�/, rrarn Oily, FL - a000r, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:23:05 2021 Page 1 I D:193QG WBBpX3jR187zeOm7kz5?ad-kboG_izd78a W 1 h7cTIsLX2Jmxg5iJ_O2Ue3NPpzwz9a -1-10-10 5-4-1 9-10-1 1-10-10 54-1 4-6-0 3x4 5-4-1 4-6-0 Scale = 1:22.5 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.60 Vert(LL) 0.09 6-7 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.63 Vert(CT) -0.12 6-7 >999 180 BCLL 0.0 Rep Stress Incr NO WB 0.34 Horz(CT) 0.01 5 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-MSH Weight: 41 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-8-1 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-10-7 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 4=Mechanical, 2=0-8-0, 5=Mechanical Max Horz 2=240(LC 8) Max Uplift 4=-170(LC 8), 2=-248(LC 8), 5=-163(LC 5) Max Grav 4=141(LC 1), 2=439(LC 1), 5=300(LC 3) FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-998/624 BOT CHORD 2-7=-689/933, 6-7=-699/932 WEBS 3-7=0/293, 3-6=-918/685 NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Bearing at joint(s) 2 considers parallel to grain value using ANSVTPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 4=170, 2=248, 5=163. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 67 lb down and 52 lb up at 1-5-12. 67lb down and 52 lb up at 1-5-12, 80 Ib up at 4-3-11, 80 Ib up at 4-3-11, and 50 lb down and 174 lb up at 7-1-10, and 50 lb down and 174 lb up at 7-1-10 on top chord, and 23 lb up at 1-5-12, 23 lb up at 1-5-12, 11 lb down and 7 lb up at 4-3-11, 11 lb down and 7 lb up at 4-3-11, and 51 lb down at 7-1-10, and 51 lb down at 7-1-10 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=-54, 5-8=-20 January I I gng1 continued on page 2 WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE. ��• Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MOW always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPl1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 23/1 WATERSTONE 2597p08,, , ti 1-17V SPECIAL 2 1 T22400466 Job Reference (optional) .ouuuara rusrauurce triant airy, FL), riani city, rL - acou r, 8.43U s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:23:05 2021 Page 2 I D: i93QG WBBpX3j RI87zeOm7kz5?ad-kboG_iZd78aW 1 h7cTIsLX2Jmxg5iJ_02Ue3NPpzwz9a LOAD CASE(S) Standard Concentrated Loads (lb) ° Vert: 11=49(F=24, 13=24) 12=36(F=18, B=18) 13=-99(F=-50, B=-50) 14=23(F=11, B=11) 15=-11(F=-5, B=-5) 16=-51(F=-25, B=-25) WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5l1912020 BEFORE USE. ��• Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall MOW building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the lyl>1Tek• fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety lnformailon available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Symbols Numbering System General Safety Notes PLATE LOCATION AND ORIENTATION 14- 13 - Center plate on joint unless x, y 74 offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and fully embed teeth. Q'11d. - -I- For 4 x 2 orientation, locate plates 0- "i ' from outside edge of truss. This symbol indicates the required direction of slots in connector plates. "Plate location details available in MiTek 20120 software or upon request. PLATE SIZE The first dimension is the plate 4 X 4 width measured perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING LOCATION Indicated by symbol shown and/or by text in the bracing section of the �r output. Use T or I bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Min size shown is for crushing only. Industry Standards: ANSIITPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 6-4-8 1 dimensions shown in ft-in-sixteenths (Drawings not to scale) 2 3 TOP CHORDS Of O U d O I— O 2 U CL O I — JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. PRODUCT CODE APPROVALS ICC-ES Reports: ESR-1311, ESR-1352, ESR1988 ER-3907, ESR-2362, ESR-1397, ESR-3282 Trusses are designed for wind loads in the plane of the truss unless otherwise shown. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. © 2012 MiTek® All Rights Reserved MiTek." MiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020 Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal orX-bracing, is always required. See BCSI. 2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered. 3. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSlfTPI 1. 7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 9. Unless expressly noted, this design is'not applicable for use with fire retardant, preservative treated, or green lumber. 10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements. 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 13. Top chords must be sheathed or purlins provided at spacing indicated on design. 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 15. Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior approval of an engineer. 17. Install and load vertically unless indicated otherwise. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient. 20. Design assumes manufacture in accordance with ANSIITPI 1 Quality Criteria. 21.The design does not take into account any dynamic or other loads other than those expressly stated.