HomeMy WebLinkAboutBLOWER DOORPlanning & Development Services
- Building & Code Regulation Division
2300 Virginia Ave, Rm 201
Fort Pierce, FL 34982
Phone:772-462-2165 Fax:772-462-6443
Date:
Contractor: M
Job Address: Y 3 0
BLOWER DOOR TEST FORM
h 'aj'j 3
House Infiltration Test Certification LJ r
Prescriptive and Performance Method b
Permit #: 2 ° o "1 - O 1+ 53
7^
Construction: (J) New Construction — Complete
P f er' e.r-L -7Q f(
) Existing — After Addition
House Infiltration Test ReSults SLC Climate Zone 2 /
CFM (50) = 8 Test Date: 31 A I L" 11
Volume = 15 ono
ACH (50) = CFM (50) x 60 / Volume = s Mechanical Ventilation required less than 3 ACH
Passing results must be & ACH (50) or less (J) Pass ( ) Fail
FBC, Energy
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes pe
hour in Gimate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
FBC, Residential
Where the air infiltration rate of a dwelling unit is Less than 3 air changes per hour when tested with a blower door at a
pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservatil
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Testing Corncany
Company Name: Pro -Duct Services Address: 1915 Rio Vista Drive, Ft. Pierce, FL 34949
I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance with Section R402.4.1.2 Climate Zone 2.
Signature:
Printed Name: Martin Klein
License/Certification #: 5061633