James and Kathleen Dwyer Load Calcs
5603 Cassia Drive load calcs INC Square Footage 2000 Cir# Description Watts Ea Total Watts Pole Trip Wire 1 General Lighting 6000 6000 1 15 14 2 Appliances 1500 3000 1 20 12 1 Dinin2 room 1500 1500 1 20 1.2 1 Dryer 5000 5000 2 30 10 1 Refrigerator/Freezer 1200 1200 1 20 12 1 Water Heater 4500 4500 2 30 10 1 Well Pump 2000 2000 1 20 12 1 Range 8000 8000 2 40 8 1 Washer 1500 1500 1 20 12 1 Dishwasher 1200 1200 1 20 12 1 t Microwave 1800 1800 1 20 12 0 1 1 20 12 Total Load 35700 First 10KW @ 100% 10000 Adjusted KW 25700 Remainder @ 40% 10280 Total of first 10%+40% 20280 Mini split#1 5KW @ 65% 3250 Mini Split#2 5KW @ 65% 3250 Total Watt Load 26780 Watt Voltage 1 phase 240 Volts Total Amperage 111.58333 Amps Freshwater&Son's Electric LLC Mark Freshwater