Loading...
HomeMy WebLinkAboutJames and Kathleen Dwyer Mitsubishi Mini Split AC System Specs Job Name: System Reference: Date: rT — Mw o ACCESSORIES C 3/8"x 1/2"Port Adapter(MAC-A454JP-E) ;. C 1/2"x 3/8"Port Adapter(MAC-A455JP-E) C 1/2"x 5/8"Port Adapter(MAC-A456JP-E) ❑ M-NET Adapter(PAC-IF01MNT-E) ❑ Base Heater(PAC-645BH-E) /Outdoor Unit: MXZ-3C24NA2 (For data on specific indoor units, see the MXZ-C Technical and Service Manual.) unj 80eciific� 'on' - Rated Capacity Btu/h 22,000/23,600 Cooling' Capacity Range Btu/h 9.500-22,000/9,500-25,500 { (Non-ducted/Ducted) — Rated Total Input W 1,62)/2,100 �— Rated CapacityCapacity Btu/h 25,000/24,600 I Heating at 47°F' ' (rapacity Range Stu/h 15,500-30,600/15,500-29,400 l (Non-ducted/Ducted) — — — --� L-- Rated Total Input W — 1,750/1,900 Heating at'7°F` Rated Capacity Btu/h 14,000/14,000 (Non-ducted/Ducted) Rated Total Input W 2,120/2,230 Connectable Capacity Btu/h I 12,000-27,000 Energy Star"(ENERGY STAR products are third-party certified by an EPA-recognized Certificaticn Body.) Yes Power Supply Voltage,Phase,Hertz 208/230V,1-Phase,60 Hz 1 Electrical Requirements Recommended Fuse/Breaker Size A — 25 — I MCA — A — 22.1 i Indoor-Outdoor S1-S2 j V AC 208/230 Voltage i Indoor-Outdoor S2-S3 V DC±24 Compressor I INVERTER-driven Scroll Hermetic Fan Motor(ECM) F.L.A. 2.43 Cooling dB(A) 51 Sound Pressure Level — Heatvng — dB(A) 55 External Dimensions(H x W x D) In 31-11/32 x 37-13/32 x 13 mm (796 x 950 x 330) Net WeightLbs/kg 137(62) External Finish Munsell No.3Y 7.8/11 Refrigerant Pipe Size O.D. -D Liquid(High Pressure) In/mm 1/4(6.35) t � Gas Low Pressure In l mm A Port:1/2(12,7);Other:3/8(9.52) Max.Refrigerant Line Length Ft/m 230(70) Max.Piping Length for Each Indoor Unit Ft/m, 82(25) Max.Refrigerant Pipe Height If IDU is Above ODU Ft!rn 49(15) Difference If IDU is Below ODU Ft/rn 49(15) Connection Method_ Flared/Flared j Refrigerant R410A `Rating Conditions perAHRI Standard: Cooling Indoor,00'F(27'(')DB 167'F(19°C)WB Heating at 47°F Indoor.70'F(210 C)DB I60'F(16'C)WB Heating at 1T F Indoor:70°F(21"C)DB Cooling!Outdoor:95°F(35'C)DB/23.9`C(75'F)WB Heating at 47°F Outdoor:471 F(8°C)DB/431 F(6"C)WB Heating at 171 F!Outdoor:17'F(-8"C)DB/15"F(-9"C)WB Specifications are subject%,change without notice. C 2019 Mitsubishi Electric Trane HVAC US,LLC OPERATING RANGE: ENERGY EFFICIENCIES: Outdoor COP @ COP @ Indoor Unit Type SEER EER HSPF Ducted and Ducted NOTES: ^ Minimum of two Indoor Units must ba connected tothe MXZ-3C24NA2. ^ Minimum installed capacity cannot bo less than 12.00OBtu/h. ^ Total connected capacity must not exceed 130%of outdoor unit capacity. ` System Gan operate with only one Indoor Unit turned on. ^ Information provided at2O8123OX ^ For Reference: ' MXZ-C Technical&Service Manual for detailed specifications and additional information per Indoor Unit Combination. ' MXZ Series Multi-Zone Indoor/Outdoor Combination Table for allowed unit combinations. K0VZ CONNECTION RULES: ^ Only 1 [NVZ may ba used on any system. ^ When onMVZio connected,total connected capacity must be1OOY6orless. ^ When an MVZioconnected, no P'Seheo indoor units ran be used(PCA. PLA.orPEAD). NOTES: � � ! | | / | / | | Specifications are subject to change without notice. 2019Mitsubishi Electric Trane HN/AC US.LLC f • NOWDUCTED: •• • • . ♦ 0♦- indoor indoor ♦. Indoor unit 111 WWII) ful B+Unit C) Unit A Unit B Uni�C 1 g 6,000 6 6,000 - 7 u 1 9 9,000 9 9,000 - 1 12 12,000 12 12,000 - - ';4 4,4 C BOG - 1 15 '14,000 15 14,000 - 1 18 17,200 18 17,200 - .6i�U 2, CO, - 2 12 '12,000 6+6 6,000 6,000 - 7 40v 4''.3 2 15 '14,000 6+9 5,600 8,400 - 2 18 18,000 6+12 6,000 12,000 1.2.'•''v1 /. 2 18 '18,000 9+9 9,000 91,000 n ;r,. 11,OOG 2 21 ;?0,000 6+15 6,000 14,000 2C e.-+ 2 21 20,000 9+ 12 8,600 11,400 22,0 ,G 9 12.500 2 24 21,800 5,600 16,200 24,0G0 6 8 6 iO3 17.900 2 24 21,800 12+12 10,900 10,900 24.000 2.00 2 000 2 24 21.800 9+15 8,500 13,300 - 24.000 9.',CIO, 14_900' - 2 27 :21,800 7,500 14,300 2Y �n0 9+18 r 90D .,v .:v 2 27 21,800 12+ 15 10,100 11,700 - 24 0 0 0 70G 3.300 18,000 6+6+6 6,000 6,000 6,000 3 18 20&0 7 g 1_ 300 7.300) 3 21 21,000 6+6+9 6,000 6,000 9,000 24.3G,, 7.10. DQ C.o0u 3 24 22,000 6+6+ 12 5,500 5,500 11,000 3 24 22,000 g+g+g 5,500 8,300 8,300 00 6 ^^,r _;A 0 0 9 40,j 3 27 24,000 6+615 5,500 5,500 12.900 0 2�E -Du0 oCC ` r,>.6� ?3.7. 24,000 5,300 8,000 10.700 3 27 2E 6+9, 12 _ 3 27 24,000 9+9+ 9 8,000 8,000 8,000 2= 8-3G 01 8,3 DID 6 gnn Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US,LLC DUCTED: . Opera pac indoor .. Indoor ttt 1 9 9,000 9 9,000 - - 10 r.9�0 1 12 12,000 12 12,000 - - 1 15 15,000 15 15,000 - i'S.j'K 18 000 _ 1 18 17,200 18 17,200 - - ?1 21 Fn0 - 2 18 18,000 9+9 9,000 9,000 - 21 8C^ 10e00 0.900 2 21 21,000 9+ 12 9,000 12,000 - 2 J0 -9 SUi; 12,2Dg 2 24 21,800 12+12 10,900 10,900 - 2- vu-I 12.000 12.:-00, 2 24 21,800 g+ 15 8,200 13,600 - 24,3010 9,1010 90U 2 27 21,800 9+ 18 7,500 14,300 - 2 27 21,800 12+15 9,700 12,100 24.11 3C^ 3.700 - 3 27 21,800 9+9+9 7,300 _7,300 7,300 _ 2-6N 8,200 8,20r 8. Specifications are subject to change without notice. ©2019 Mitsubishi Electric Trane HVAC US,LLC Unit: inch 3-�,VW 2—Sloc.t N.fz:`,et--le T MTD) 3/32'.. -iZ 7 L II /41 6-o'-5f16' Ho!? !I fat ;z psc 2-�!5132'X�-13J3 7LT)Ovo,role 1-1132* 2-o7/8*k-;0-k-": ,ae Bolt mtD) 2 3-718--c-.-hose 37-13/BT 3' 19/32' (Con-c-;ng.1e C: A�, -,eke '-A�5 318--52�,ARE J ==J �GAS L?Q A L Lo Q! �--.IJ32 14-7/32* zz, 1.FREE SPACE L ,'3-25132' �7—�e Conduit plates Conduit connector 2.SERVICE SPACE O --D Lock nut ',3-25132 01 more 3-25!32' or,more MITSUBISHI .ffl& ELECTRIC COOLING & HEATING 1340 Satellite Boulevard.Smance.GA 30024 Toll 7ree:800-433-4822 www.mehvac.com LEM= E1� C us Intertek Specifications are subject to change without notice. @ 2019 Mitsubishi Electric Trane HVAC US,LLC j # 6 t is -I fit, • I Job Name: System Reference: Date: Indoor Unit: Wireless Remote Controller MSZ-GL09NA GENERAL FEATURES • Slim wall-mounted indoor units provide zone comfort control • The outdoor unit powers the indoor unit,and should a power outage occur,the system is automatically restarted when power returns • Multiple fan speed options:Quiet,Low, Medium, High,Super-high,Auto • Multiple control options available: -Hand-held Remote Controller(provided with unit) -kumo cloud smart device app for remote access -Third-party interface options -Wired or wireless controllers • Hot-Start Technology: no cold air rush at equipment startup or when restarting after Defrost Cycle • Quiet operation • Smart Set:recalls a preferred preset temperature setting at the touch of a button Specifications are subject to change without notice. (5- 2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. Cooling Capacity" 3 BTUiH 9,000 ----------.----------- -_ ---- _---- _ - - __ ___ ___--------- -- ---- ._ -.----- ---------._.._.__-- Heating Capacity2 3 BTUM 10,900 Voltage, Phase, Frequency 208/230V, 1 phase,60Hz Guaranteed Voltage Range VAC 87-253 Electrical Voltage. Indoor-Outdoor,S1-S2 V AC 208/230 Voltage: Indoor-Outdoor,S2-S3 V DC 24 Short-circuit Current Rating(SCCR) 5 MCA A 1 Blower Moto-Full Load Amperage A 0.76 Blower Moto-Out out W 30 Airflow Fate at Cooling, Dry CFM 399-321-237-170-145 Airflow Rate at Cooling,Wet CFM 364-286-201-134-109 Airflow Rate at Heating,Dry CFM 406-321-237-170-145 Sound Pressure Level(Cooling) dB(A) 43-:37-30-22-19 Sound Pressure Level (Heating) dB(A) 43-:37-30-22-19 Drain Pipe Size In.(rnm) 5/8(15.88) -- ------ ---- - - - - -- - ---------- ----- - - ---- --- - -- ------ -- Heat Exchanger Type Plate fin coil External Finish Color Munsell 1.OY 9.2/0.2 W: In.(mm) 31-7/16(798) Unit Dimensions D. In.(mm) 9-1/8(232) H: In-(mm) 1-1-58(295) %N: In. (mm) 33-1/2(850) Package Dimensions 0 In. (mm/ 12(300) H:In. (mm) 14(350) --------------- Unit Weight Lbs. (kg) 22(10) Package Weight Lbs. (kg) 26(11.5) Refrigerant Type R41OA Gas Pipe Size O.D.(Flared) in.(rnm) 3i8(9.52) Piping ---- __ - -- - Liquid Pipe Size O.D.(Flared) n. (mm) 1!4(6.35) Notes: 'Cooling(Indoor!'Outdoor) T 80 DB.67 WB//95 DB,75 WB Nominal Conditions - - - -- - - - - - - - -- - - -- - 21-leating at 47°F(Indoor li Outdoor) T 70 DB.60 WB r1 47 DB,43 WB 3Capaci-.y varies based on the number of indoor units operating and the model of the Multi-zone Outdoor Unit. For reference to connected capacity charts,please refer Multi-zone Outdoor Unit Operational Performance:. Specifications are subject to change without notice. ©2020 Mittsub:shi Electric Trane HVAC US LLC.All rights reserved. a s Anti-allergy Enzyme Filter _MAC-408FT-E kumo touch"°" RedLINKT"Wireless Controller -MHK2 Deluxe MA Remote Controller' _ PAR-40MAAU Simple MA Controller' PAC-YT53CRAU-J Touch MA Controller' _PAR-CT01 MAU-SB Wired Remote Sensor M21-EAA-307 Wireless Temperature and Humidiy Sensor PAC-USWHS003-TH-1 System Control Interface2 IAAC-3341F-E Wireless Interface 2 PAC-USWHS002-WF-2 Thermostat Interface _PAC-US444CN-1 kumo stations PAC-WHS01HC-E USNAP Interface PAC-WHS01UP-E IT Extender = PAC-WHS011E-E BACnet''and MODBUSV Interface PAC-UKPRC001-CN-1 Lockdown Bracket for Hand-held Remote Controllers _ RCMKP1CB Blue Diamond Sensor Extension Cable—15 Ft. - C13-103 Blue Diamond Alarm Extension Cable—6.5 Ft. _ C13-192 Blue Diamond MultiTank—collect on tank for use with multiple pumps C21-014 Blue Diamond Rubber Foot Pads F10-010 Mini Condensate Pump-230 volt application =S130-230 MegaBlue Advanced Blue Diamord Condensate Pump w/Reservoir&Sensor X87-835-110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w;Reservoir 8 Sensor(110V)up to 48.000 BTU? X87-711 -110V H[recommendeal Advanced Blue Diamond Mim Condensate Pump wr Reservoir&Sensor(208./230V)[recommended] - X87-721 -208i230V MicroBlue Blue Diamord Mini Condensate Pump(110/208!230V)up to 18.000 BTU-H =X85-003 Fascia Kit for MicroBlue Pump—mounts the MicroBiue and sensor directly beneath the indoor unit T18-016 Drain Pan Level Sensor S3610E (30A/600V/UL)[fits 2"X 4'utility Eox]-Black -TAZ-MS303 (30A/600V/UL)[fits 2"X 4"utility box]-White TAZ-MS303W Requires MAC-3341F-E 2 Allows indoor units to connect to an VA Controller Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. Unit: inch 1116xl oblong hole 1/'6xl3116 Oblong hole Installation late 3-1/8 3i-7/16 �I Ik 30-15/16 114 Zhl2-3/ l 13-5/16 1 13-9/1A l f i3/16 Indoor unit Insfallotior. plate -- �� I "i— S/I6 5 1 t-3/4 24-3/8 —'nF-- —' I hose —_ 4 3/16,; ho 2 s/i6 3/4 4-31 Air o u r -1 — — Insulation 01-318 O-D — aLiquid line o114 19-11/16(Flared connectioncn o114� a Gas line o318 16-15116 5!1 6 Ll (Rared connection:o3I8(06109112 KSTUIH)..0112(15 KSTU/H) Drain hose ,Insulation of-1/8 O.D Connected part o518 0.0 1340 Satellite Boulevard,Suwanee.GA 30024 To!!Free:800-433-4822 www/.m'�ehvac.com r. us FORM#MSZ-GL09NA FOR MXZ-C MULTI-ZONE HEAT PUMP SYSTEMS-202003 Intertek Specifications are subject to change without notice. Q 2020 Mitsubishi Electric Trane HVAC US LLC-All rights reserved. Jot Narne: System Reference: Date: Indoor Unit: Wireless Remote Controller MSZ-GL06NA GENERAL FEATURES • Slim wall-mounted indoor units provide zone comfort control • The outdoor unit powers the indoo unit,and should a power outage occur,the system is automatically restarted when power returns • Multiple fan speed options:Quiet, Low, Medium.High,Super-h gh,Auto • Multiple control options available: Hand-held Remote Controller(provided with unit) kumo cloud smart device app for remote access Third-party interface options Wired or wireless controllers • Not-Start Technology: no cold air rush at equipment startup or when restarting after Defrost Cycle • Quiet operation • Smart Set:recalls a preferred preset temperature setting at the touch of a button Specifications are subject to change without notice. v 2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. Cooling Capacity' 3 BTU/H 6,000 Heating Capacity2 3 BTU!H 7,200 Voltage,Phase, Frequency 208/230V, 1 phase,60Hz Guaranteed Voltage Range VAC 187-253 Electrical Voltage: Indoor-Outdoor,S1-S2 V AC 208/230 Voltage: Indoor-Outdoor,S2-S3 V DC 24 Short-circuit Current Rating(SCCR) Wireless Type MCA .A 1 Blower Motor Full Load Amperage A 0.76 Blower Motor Output W 30 Airflow Rate at Cooling, Dry CFM 145-170-237-321-399 Airflow Rate at Cooling.Wet CFM 109-134-201-286-364 Airflow Rate at Heating,Dry CFM 145-170-237-321-406 Sound Pressure Level(Cooling) dB(A) 19-22-30-37-43 Sound Pressure Level(Heating) dB(A) 19-22-30-3743 Drain Pipe Size In (mm) 5/8(15.88) Heat Exchanger Type Plate fin coil External Finish Color Munsell 1.0Y 9.210.2 - W:In. (mm) 31-716(798) Unit Dimensions D: In. (mm) 9-1/8(232) H In. (mm) 11-5/8(295) W: In. (mm) 33 1/2(850) Package Dimensions D: In. (mm) 12(300) H: In.(mm) 14(350) Unit Weight Lbs. (kg) 22(10) Package Weight Lbs. (kg) 26(11.5) Refrigerant Type R410A Gas Pipe Size O.D. (Flared) In. (mm) 3/8(9.52) Piping - Liquid Pipe Size O-D. (Flared) In. (mm) 1/4(6.35) Notes: 'Cooling (Indoor//Outdoor) °F 80 DB,67 WB/!95 DB,75 WB Nominal Conditions ----- ZHeating at 47°F(indoor 11 Outdoor) °F 70 DB.60 WB/I 47 DB,43 WB 3Capacity vanes based on the number of indoor units operating and the model of the Multi-zone Outdoor Unit.For reference to connected capacity charts,please refer Multi-zone Outdoor Unit Operational Performance. Specifications are subject to change without notice. 2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. Anti-allergy Enzyme Filter =MAC-408FT-E kumo touch"'" RedLINKI Wireless Controller MHK2 Deluxe MA Remote Controller' PAR-40MAAU Simple MA Controller' - PAC-Y753CRAU-J Touch MA Controller' PAR-CT01 MAU-SB Wired Remote Sensor M21-EAA-307 Wireless Temperature and Humidity Sensor PAC USWHS003-TH-1 System Control Interface` - MAC-3341F-E Wireless Interface 2 PAC-USWHS002-WF-2 Thermostat Interface PAC-US444CN-1 kumo station" PAC-WHS01HC-E USNAP Interface PAC-WHS01 UP-E IT Extender -PAC-WHS011E-E BACnet-' and MODBUS Interface PAC-UKPRC001-CN-1 Lockdown Bracket for Hand-held Remote Controllers RCMKP1CB Blue Diamond Sensor Extension Cable--15 Ft. - C13-103 Blue Diamond Alarm Extension Cable-6.5 Ft. _C13-192 Blue Diamond MultiTank—collection tank:for use with multiple pumps C21-014 Blue Diamond Rubber Foot Pads F10-010 Mini Condensate Pump—230 volt application -S130-230 MegaBlue Advanced Blue Diamond Condensate Pump w/Reservoir&Sensor X87-835-110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/Reservoir&Sensor(110V)up to 48.000 BTU/ _X8 7-711 - 110V H[recommended] Advanced Blue Diamond Mini Condensate Pump w/Reservoir&Sensor(208/230V)[recommended] X87-721 -208/230V MicroBlue Blue Diamond Mini Condensate Pump(110/208/230V)up to 18,000 BTU/H =X85-003 Fascia Kit for MicroBlue Pump-mounts the MicroBlue and sensor directly beneath the indoor unit T18-016 Drain Pan Level Sensor _SS610E (30A/600V/UL)(fits 2"X 4"utility box]-Black -TA7_-MS303 (30A/600V/UL)[fits 2"X 4"utility box]-White =TALI-MS303W Requires MAC-3341F-E 2 Allows indoor units to connect to an MA Controller Specifications are subject to change without notice. v 2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. Unit: inch 1116X1 Obloog hole 7116X13116 Oblong hole 3 I I n s t a l l a i i o nplate 3-1 18 8-7/8- ----�" 8-7/8 /8---°1 _ 31-7lI6 30-15/16 1/4 I ]-7Z 6-1/8 6-1/8 a 3l 13-5/16 ,jE 13-9/!6 9-i 3/16 , l8/8 Indoor unit A 1r I( oll hole 43 I V Installation plate —1 777 — � I M �_ I �- 1 518 ��� 1-314 5/16� 24-3/8 5=1. /8� 4-3/16XI�I Drain hose 2'S/16.; 3/d ' 4-31 Air out =1 —� insulation ol-3/8 O.D —j ,••���� a Liquid line m114 19-11/16(Flared connec5on m1/4) 2 Gas line m3/8 16-15/16 (Flared connection:e318(06tp9N2 KSTUIH),e112(15 KBTUM)i 3/ 6 Drain hose Insulation m1-1l8 O.D Connecte part m518 O.D J 1340 Satellite Boulevard.Suwanee,GA 30024 Toll Free 800-433-4822 mvw.mehvac.com =T � a FORM#MSZ-GL06NA FOR MXZ-C MULTI-ZONE HEAT PUMP mm ETA SYSTEMS-202003 lntertek Specifications are subject to change without notice. D 2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. Job Name: System Reference: Date: Indoor Unit: Wireless Remote Controller MSZ-GL15NA 757 11— aae GENERAL FEATURES • Slim wall-mounted indoor units provide zone comfort control • The outdoor unit powers the indoor unit,and should a power outage occur,the system is automatically restarted when power returns • Multiple fan speed options:Quiet,Low, Medium, High.Super-high,Auto • Multiple control options available: Hand-held Remote Controller(provided with unit) kumo cloud smart device app for remote access Third-party interface options Wired or wireless controllers • Hot-Start Technology: no cold air rush at equipment startup or when restarting after Defrost Cycle • Quiet operation • Smart Set: recalls a preferred preset temperature setting at the touch of a button Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. i 6 Cooling Capacity,,3 BTU/H 14,000 Heating Capacity2 3 BTU/H 18,000 Voltage, Phase, Frequency 208/230V, 1 phase,60Hz Guaranteed Voltage Range VAC 187-253 ElecVic:al Voltage: Indoor Outdoor,S1-32 VAC 208 i 230 ----- - --- ------- -- Voltage: Indoor-Outdoor,S2-S3 V DC 24 Short-circuit Current Rating(SCCR) 5 - -- ---- — --- - ---- - - - - -- - -- ------- ------- MCA A 1 Blower Motor Full Load Amperage A 0.76 Blower Motor Output h 30 Airflow Rate at Cooling; 'Dry CFM 533-420-335-272-205 Airflow Rate at Cooling,Wet CFM 498-385-300-237-170 Airflow Rate at Heating, Dry CFM 463-367-304-247-205 Sound Pressure Level(Cooling) dB(A) 49-44-38-32-26 Sound Pressure Level(Heating) dB(A) 46-40-35-30-26 Drain Pipe Size In (mm) 5/8(15.88) Heat Exchanger Type Plate fin coil External Finish Color Munsell 1.0Y 9.2/0.2 W In. (mm) 31-7I16(798) Unit Dimensions D: In. (mm) 9-1/8(232) H In.(mm) 11-5/8(295) W: In. (mm) 33-1/2(850) Package Dimensions D: In.(mm) 12(300) H:In.(mm) 14(350) Unit Weight Los. (kg) 22(10) Package Weight Los. (kg) 26(11.5) Refrigerant Type R410A Gas Pipe Size O.D.(Flared) In. ;mm) 1/2(12.7) Piping --- - - Liquid Pipe Size O.D.(Flared) In. "mm) 1!4(6.35) Notes: 'Cooling(Indoor!i Outdoor) T 80 DB,67 WB//95 DB.75 WB Nominal Conditions -- -- - ------- -- --- -- -- --- ----- ------ ----- - -- -- ZHeating at 47'F(indoor;/Outdoor) T 70 DB, 60 WB//47 DB,43 WB 3Capacity varies based on the number of indoor units operating and the model of the Multi-zone Outdoor Unit.For reference to connected capacity charts,please refer Multi-zone Outdoor Unit Operational Performance. Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. Anti-allergy Enzyme Filter = MAC-408FT-E kurno touch"' RedLINK"I Wireless Controller MHK2 Deluxe MA Remote Controller) PAR-40MAAU Simple MA Controller' PAC-YT53CRAU-J Touch MA Controller) _PAR-CT0IMAU-SB Wired Remote Sensor M21-EAA-307 Wireless Temperature and Humidity Sensor PAC-USWHS003-TH-1 System Control Interface =MAC-3341F-E Wireless Interface 2 PAC-USWHS002-WF-2 Thermostat Interface _ PAC-US444CN-1 kurno stations' PAC-WHS01 HC-E USNAP Interface PAC-WHS01 UP-E IT Extender = PAC-WHS011E-E BACnef=and MODBUSI Interface PAC-UKPRC001-CN-1 Lockdown Bracket for Hand-held Remote Controllers RCMKP1 CB Blue Diamond Sensor Extension Cable-15 Ft. C13-103 Blue Diamond Alarm Extension Cable—6.5 Ft. C13-192 Blue Diamond MultiTank—collection tank for use with multiple pumps -C21-014 Blue Diamond Rubber Foot Pads : F:0-010 Mini Condensate Pump-230 volt application S130-230 MegaB,ue Advanced Blue Diamond Condensate Pump w/Reservoir&Sensor X87-835- 110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump yr Reservoir&Sensor(!10V)up to 48,000 BTU! _X87-711 -110V H[recommended] Advanced Blue Diamond Mini Condensate Pump w/Reservoir&Sensor(208/230V)[recommended] X87-721 -208/230V MicroBlue Blue Diamond Mini Condensate Pump(110/208/230V)up to 18.000 BTU/H c X85-003 Fascia Kit for MicroBlue Pump--mounts the MicroBlue and sensor directly beneath the indoor unit T18-016 Drain Pan Level Sensor _SS610E (3CA/600V/UL)[fits 2"X 4"utility box]-Black TAZ-MS303 (30A1600V/UL)[fits 2"X 4"utility box]-White TAZ-MS303W Requires MAC-3341F-E 2 Allows indoor units to connect to ar,MA Controller Specifications are subject to change without notice. O 2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. e e Unit: inch 7116xl Oblong hol! 7/16xl3/16 Oblong hole Installation lofe 3-1/8 8-7/8 8-7/8 I18 m 31-7/16 �I � 30.15116 -114 —1 C I i m I 6-118 —I 2 3/ 3 sll6 3 9/16 2-I/8 9-1/8 3/16 Air In all hole 43 — Indoor unit fl V Insiailation Dlafe _ Pi 'n 3/4 5/i6 24 3!8 5-I/8 \ d 3116�'�I Drain hose A 3t N AIf O U t Insulation m1-318O.D d connection m1l4)I Liquid line m1/4 19-11/16(Flare� _ a Gas line m3/8 16-15/16 2 3/16 S/16 3/'i 6 (Flared connection.o3i8;0610112 KBTUM),m112(15 KBTUM) Drain hose Insulation m1-1/8 O.D Connected part m5/8 O.D 1340 Satellite Boulevard Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com r ' c omFORM MSZ-GL15NA FOR MXZ-C MULTI-ZONE HEAT PUMP SYSTEM us -202003 Intertek Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. Job Pro ect Summa Date: s -� Wrightsoft- 1 � Dale: Dec't2,2020 Entire House By. PATRICK S MESMER TWC Services 7950 Certral Industrial Dr.Ste#101,Rivera Bead;FL33404 Phone:?(561)246-8542 Email:patmesmergtwservices.00m • ion, • • For. KATHYAND JIM DWYER,WAGNER'SACAND REFRIGERATION FORT PIERCE,FL Notes: D4sign Information1l Weather. Vero Beach Municipal AP,FL,US Winter Design Conditions Summer Design Conditions Outside db 43 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 27 OF Design TD 16 °F Daily range L Relative humidity 50 % Moisture difference 59 gulb Heating Summary Sensible Cooling Equipment Load Sizing Structure 17175 Btuh Structure 22829 Btuh Ducts 6839 Btuh Ducts 10587 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 dim) 0 Btuh none Humidification 0 Btuh Blower e) 0 Btuh Piping 0 Btuh Equipment load 24014 Btuh Use manufacturers data n Rate/swingg rnulti ier 0.95 Infiltration Equipmentsensille load 31912 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3836 Btuh Ducts 2754 Btuh Central vent(0 cfm) 0 Btuh Heatingg Coolin'q (none) Area(ft2) 1783 1783 Equipment latent load 6590 Btuh Volume(ft3) 16824 16824 Air changes/bour 0.38 0.20 Equipment Total Load(Sen+Lat) 38503 Btuh Equiv AVF(cfm) 107 56 Req.total capacity at 0.70 SHR 3.8 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80AFUE Efficiency 0SEER Heating input 0 Btuh Sensible coding 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 OF Total cooling 0 Btuh Actual airflow 1359 cfrn Actual airflow 1359 cfm Air flow factor 0.057 cfm/Btuh Airflowfactor 0.041 cfm/Btuh Staticpressure 0 in H.20 Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.84 Calculations approved byACCA to meet all requirements of Manual J 9th Ed_ " wrigl7tsoft' 2020-Dec-1217:15 21 �� -`---����--� Riglt-SuteJUnversa1201919.0.19RSU02634 Pagel .SISANJAYHEATLOADMAGNERSDWYERRESIDENCE.rnp Calc=MJ8 Frort Door faces:N N Level 1 30'-0"— —1 U-0" BaV ctr 195 cfm STAIRWELL 30'4D" PANTRY BAk 5 cim � 8 cfrl 144 cfrr, \ FLORIDA ROOM \ 144 cfrn �144 c C4 Nl%86 cfrn KITHCHEN 101 cfm 101 cfrn Job#:3 TWC Services Scale: 1 :87 Performed by PATRICK S MESMER for: RzUe2 KATHY AND J$)DWYER 7950 Central Ind ustial Dr.Ste#101 Rift-Suites Universal 2019 Riviera Beach,FL 33404 19.0.19 RSUQ2634 FORT PIERCE,FL Phone:1(561)246..8542 2M-Deo-1217:1616 patmesmer@Wc,services.com ...OADWPGNER'S DWYER RESIDENCErup