Loading...
HomeMy WebLinkAboutPile Report 1310 Neptune Drive Boynton Beach,Florida 33426 Nulling . Toll Fr 6-4900 Toll Free:877-NUTTING(688-8464) Engineers Fax:561-73 Broward 954-941-8-941-8700 St.Lucie 772-408-1050 of Florida Inc.I Established 1967 Miami-Dade 305-557-3083 Your Project is Our Commitment www.nuttingengineers.com September 18, 2017 Mr. Tom Butler Bodax Foundations, Inc. 1101 NW 55th Street E Ft. Lauderdale, Florida 33309 rZ 0 L Subject: Report of Augercast Pile Installation Monitoring w Simmermacher Residence U1 7912 South Ocean Drive 0 Jensen Beach, Florida U N U Dear Mr. Butler: C: Nutting Engineers of Florida, Inc. (NE) has completed observation of augercast piling operations a, for the proposed residence and pool at the subject site. Bodax Foundations, Inc. installed cast-in- place augured piles for support of the proposed construction. Ln 6 Bodax Foundations, Inc. installed a total of seventy-two (72), 14-inch diameter auger cast piles E for the project. The piles were installed between August 29, 2017 and August 31, 2017. Please •L refer to the pile plan for the numbering. The pile size and depth recommendations were based upon the "Report of Geotechnical Exploration" report prepared by GFA International dated C December 15, 2016. ro The pile installation characteristics of each pile are presented in the attached Pile Installation Data. Identification of each pile location followed by the pile number is shown on the Pile Location Plans attached. Each pile record in the attached summary tables shows the following C: information: 0 U ■ RECORD NUMBER IN CHRONOLOGICAL ORDER N ■ THE PILE NUMBER(AS FOUND ON ATTACHED PLANS) o ■ THE DIAMETER OF THE PILE THE LENGTH OF PILE FROM GROUND SURFACE TO TIP ■ THE THEORETICAL VOLUME OF GROUT FOR THE PILE ■ THE NUMBER OF PUMP STROKES FOR THE PILE `-' ■ THE ACTUAL VOLUME OF GROUT FOR THE PILE C ■ THE GROUT FACTOR ■ THE DATE OF INSTALLATION ■ THE REINFORCEMENT TYPES ■ AND GENERAL COMMENTS AS NEEDED O F F I C E S F�F,� Palm Beach COFILE -Dade Py Miami nrlxrvExsnrzY T S t . L u c i e The drilling operations were monitored in the field by our field engineer and inspector in order to approximately determine the type of material being penetrated. This identification was done based on the augering time, the materials received during the drilling operations and the relative hardness of the soils/rocks as indicated by the vibration or"chattering" of the hydraulic lines. The augercast piles were installed to a depth of thirty feet below the existing ground surface. The piles were designed for an allowable compressive capacity of 30 tons as required by the structural specifications and the recommendations made in the referenced report by GFA International. Piles for the proposed residence received steel reinforcement consisting of one full-length, centered#7 reinforcing bar and a cage consisting of five, 15-feet long#5 reinforcing bars with#3 ties spaced 10-inches on center as stated in the structural documents. Piles for the proposed pool received steel reinforcement consisting of one full-length, centered#7 reinforcing bar and a cage consisting of five, 19-feet long #5 reinforcing bars with #3 ties spaced 10-inches on center as stated in the structural documents. Upon completion of this inspection process, and review of the recorded data, it is our opinion that the augercast piles installed for the proposed residence and pool attained the required design compressive capacity of 30 tons. The piles were installed in substantial compliance with the plans and specifications. We note that it was monitored and ensured that the piles began installation at the survey locations provided in.the field. If during drilling operations it was discovered that gross deviations from original locations have occurred, the deviation was attempted to be rectified. Nutting Engineers is not responsible for minor deviations which have occurred during drilling operations, along with incorrect surveyed pile locations. This condition is beyond the control of the site inspector and undersigned engineer. . Our client for this project was: Mr. Tom Butler Bodax Foundations,Inc. 1101 NW 55th Street Ft. Lauderdale, Florida 33309 The contents of this report are for the exclusive use of the client, the client's design & construction team and governmental authorities for this specific project exclusively. Information conveyed in this report shall not be used or relied upon by other parties or for other projects without the expressed written consent of NE. Hutling le Engineers of Florida Inca Established 1967 2 ?ANNWERSARY T 1967-2017. We appreciate this opportunity to work with you on this project and look forward to completing this and future projects with you. Should you have any questions or if we can be of any further assistance, please contact us at your convenience. Respectfully Submitted, NUTTING ENGINEERS OF FLORIDA,INC. Richard C. Wohlfarth, E. Steph rachek, P.E. #70784 Director of Engineering Senior Engineer Attachments: Pile Location Plans Pile Installation Data LTR BODAX SIMMERMACHER RESIDENCE 7912 S OCEAN DR JENSEN ACP SJM Nutting a Engineers of Florida Inc. Established 1967 I. 3 -10NMRSARYT 1967-2017 j 12 15 I n¢ �srrrf ' t G,¢.9DE SEAM..-Ck DOLE a;� �• samni��s'uuv�f g%l=rP�rv.'A�..cams�rieucaavrr Ir,,,,a -=„-_r.• -: 3 o__,i P-0, liGQ"39 P1LGSCL �!.'mnvnwxe>r�c ;txwzrmau:,w m.rnfAa waA' � ra-f I > ! — x'rum.•� I 4',3` Y aax ei.-r �p� 3�.a- wltuawAf:Afr��.ro�im.RYA:t'mft rawue.nelc R _ }r': ��::r..c..•.s a}cldflM1LL R1C®PALL letdldC(O:S•�cnffpeatrdr{at3 i:'» ...,. / 9i�— vx�mrsvaxmv_wtm�+..e>C[°].T34YDSi%Si11E•JArAi]fDArE01 I n+s a,e 1n,e «I rvs� i. gl ff4HliaBGTAlCitGi 1K!I[itU 4ID?JPIL7EYLISJNU.fd2>�AfOt^3v �rY 1 � G� ��� fi�Ab LCk]r'.P.1Ct�1.SVDliOSUt£2biP6tR'OC)NOM,ID N'TO !G l�.'ClLLA2C'RM(hJ✓LRlil'IifA.B9If27O Y•?IRYi 2E101it119f iy`� tom' �snccnxLn>�s.xf:ra%+airAr�n.�cr�:rraTv�cam.r+ouunwt �•vwr,c�;'.,".4-��rl — — ir.��aru� I $�H' urswlr vrr•.vArenortl nxrvtmsNne:a>cAaa>-Aro,vL we+x nta+ ate: { a. ixo , NAYS.W9i0Vl1mcCa[al'.aIRAJVLtf�rA2 cPm P_rti•.nru �YY ocnnoro' — I — SY.i_P 2» �.•. f_YBYN�S_ CdER ATMR.'!a CpIW)G6F4R:'QL xWs JLt• 2'L PMSXI4TtQ ' � j —cYtc9 C:�0c7tc_r P+OYlL AWKEr.Kish WMb AaLLtBWt�Of1>:bYS}fCGMIX' IY•> %S�StP XL�c:s — — 1� xb�w � 1 4'. lSL��wb^ey A9WY.vt P1I511C�A�2fR�0.11fYWLGp'9TR .a i%151: � — — � � H�;••w 1 � �� i pSl t02 L3�Aii ArA MO].tLtl:OR RIrP Ai'.8G8�c!'G424 �_ 9JiLR '!Av'O:P�TKCu.Dki^�HMl5Md0ii1W M[[�OCM%W'M j KRd11310J1vR Kl�`CJ INMOC'V14gfRA:F M2 �r I � L G4 ISOLATED PAD/PILE CAP _ Ale ,L it QVZ �'I e•-'Foi `er m�vr�R _ 33 a.' a� I md' c+ t , ED3.5 KETI It ( i I !_ � A! i n T - r♦ j oq LE1iY.u.FCCL-ZW: 1 L' .�.r F ` i DAV rQ A-4 PILING PLAN t/.'.V_ 7W 2. .5 —6 !40. rA- T-V ej FLUSH SPA PjOTE-. Ff= EX.RESIDENCE EX.RES]DENC VIE) POOL PILING PLAN FOOL LAYOUT&PIPING PLAN tl 17-79� 1 - 3 • DODAX FOUNDATION SliiI MERMACHER RESIDENCE 7912 S OCEAN DRIVE JENSEN BEACH, FLORIDA PILE LOG DATA OF AUGERCAST PILE INSTALLATION NUTTING ENGINEERS OF FLORIDA, INC. Theoretic. Total Pile Record Pile Dia. Pile Pump Volume of Grout Date Pile No. Length Grout Remarks No. (in) (ft) Volume Strokes pumped Factor Installed (ft ) fts 1 45 14.0 30 32.1 65 36.4 1.14 08/29/17 2 47 14.0 30 32.1 71 39.8 1.24 08/29/17 3 48 14.0 30 32.1 75 42.0 1.31 08/29/17 4 50 14.0 30 32.1 69 38.6 1.20 08/29/17 5' 49 14.0 30 32.1 78 43.7 1.36 1 08/29/17 6 46 14.0 30 32.1 74 41.4 1.29 08/29/17 7 44 14.0 30 32.1 76 42.6 1.33 08/29/17 8 43 14.0 30 32.1 87 48.7 1.52 08/29/17 9 36 14.0 30 1 32.1 79 44.2 1.38 08/29/17 10 34 14.0 30 1 32.1 73 40.9 1.27 08/29/17 11 68 14.0 30 32.1 70 39.2 1.22 08/29/17 Pool Pile 12 67 14.0 30 32.1 80 44.8 1.40 08/30/17 Pool Pile 13 33 14.0 30 32.1 73 40.9 1.27 08/29/17 14 3 14.0 30 32.1 66 37.0 1.15 08/29/17 15 4 14.0 30 32.1 68 38.1 1.19 08/29/17 16 17 14.0 30 32.1 69 38.6 1.20 08/29/17 17 2 14.0 30 32.1 63 35.3 1.10 08/29/17 18 54 14.0 30 32.1 70 39.2 1.22 08/29/17 19 61 14.0 30 32.1. 67 37.5 1.17 08/29/17 20 10 14.0 30 32.1 74 41.4 1.29 08/29/17 21 11 14.0 30 32.1 69 38.6 1.20 08/29/17 22 14 14.0 30 32.1 67 37.5 1.17 08/29/17 23 12 14.0 30 32.1 73 40.9 1.27 08/29/17 24 15 14.0 30 32.1 72 40.3 1.26 08/29/17 25 13 14.0 30 32.1 67 37.5 1.17 08/29/17 26 8 14.0 30 1 32.1 62 34.7 1.08 08/29/17 27 9 14.0 30 32.1 65 36.4 1.14 08/29/17 28 65 14.0 30 32.1 76 42.6 1.33 08/30/17 Pool Pile 29 72 14.0 30 32.1 93 52.1 1.62 08/30/17 Battered 30 66 14.0 30 32.1 81 45.4 1.41 08/30/17 Pool Pile 31 69 14.0 30 32.1 78 43.7 1.36 08/30/17 Battered 32 70 14.0 30 32.1 82 45.9 1.43 08/30/17 Pool Pile 33 71 14.0 30 32.1 84 47.0 1.47 08/30/17 Pool Pile 34 35 14.0 30 32.1 79 44.2 1.38 08/30/17 Pool Pile 35 51 14.0 30 32.1 88 49.3 1.54 08/30/17 36 52 14.0 30 32.1 76 42.6 1.33 08/30/17 37 41 14.0 30 32.1 74 41.4 1.29 08/30/17 38 39 14.0 30 32.1 80 44.8 1.40 08/30/17 Hutting IDof Florida Inc Established 1967 jANNNERSARY I 1967-20.1 - i BODAX FOUNDATION SIMMERMACHER RESIDENCE 7912 S OCEAN DRIVE JENSEN BEACH, FLORIDA PILE LOG DATA OF AUGERCAST PILE INSTALLATION NUTTING ENGINEERS OF FLORIDA, INC. Theoretic. Total Record Pile Dia. Pile Pile Pump Volume ofGrout Date No. Pile No. (in) Length Volume Strokes Grout Factor Installed Remarks (ft) (ft3) Pumped ft 39 5 14.0 30 32.1 75 42.0 1.31 08/30/17 40 6 14.0 30 32.1 78 43.7 1.36 08/30/17 41 32 14.0 30 32.1 73 40.9 1.27 08/30/17 42 1 31 14.0 30 32.1 68 38.1 1.19 08/30/17 43 29 14.0 30 32.1 72 40.3 1.26 08/30/17 44 37 14.0 30 32.1 76 42.6 1.33 08/30/17 45 40 14.0 30 32.1 80 44.8 1.40 08/30/17 46 53 14.0 30 32.1 73 40.9 1.27 08/30/17 47 55 14.0 1 30 32.1 67 37.5 1.17 08/30/17 48 38 14.0 30 32.1 74 41.4 1.29 08/30/17 li 49 42 14.0 30 32.1 75 42.0 1.31 08/30/17 50 30 14.0 30 32.1 82 45.9 1.43 08/30/17 51 7 14.0 30 32.1 66 37.0 1.15 08/30/17 52 1 14.0 30 32.1 65 36.4 1.14 08/30/17 53 18 14.0 30 32.1 71 39.8 1.24 08/30/17 54 64 14.0 30 32.1 67 37.5 1.17 08/30/17 55 63 14.0 30 32.1 74 41.4 1.29 08/30/17 56 21 14.0 30 32.1 68 38.1 1.19 08/30/17 57 56 14.0 30 32.1 74 41.4 1.29 08/31/17 58 27 14.0 30 32.1 81 45.4 1.41 08/31/17 59 19 14.0 30 32.1 67 37.5 1.17 08/31/17 60 23 14.0 30 32.1 70 39.2 1.22 08/31/17 61 16 14.0 30 32.1 80 44.8 1.40 08/31/17 62 26 14.0 30 32.1 74 41.4 1.29 08/31/17 63 20 14.0 30 32.1 71 39.8 1.24 08/31/17 64 24 14.0 30 32.1 66 37.0 1.15 08/31/17 65 22 14.0 30 32.1 72 40.3 1.26 08/31/17 66 25 14.0 30 32.1 65 36.4 1.14 08/31/17 67 28 14.0 30 32.1 66 37.0 1.15 08/31/17 68 62 14.0 30 32.1 89 49.8 1.55 08/31/17 69 58 14.0 30 32.1 74 41.4 1.29 08/31/17 70 57 14.0 30 32.1 78 43.7 1.36 08/31/17 71 60 14.0 30 32.1 80 44.8 1.40 08/31/17 72 59 14.0 30 32.1 75 42.0 1.31 08/31/17 Total linear feet drilled 2160 Total Grout(yd ) 110 Minimum depth drilled 30 Maximum depth drilled 30 PILE LOG FL BODAX SIMMERMACHER RES 7912 S OCEAN DR JENSEN ACP.xIs Nulling of Florida Inc. Established 1967 "NI19s7VERSA$Y T -2917