HomeMy WebLinkAboutEngery Calcs FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: SIMMERMACHER RESIDENCE Builder Name: COASTAL CONSTRUCTION Street: 7912 S.OCEAN DRIVE Permit Office: ST.LUCIE COUNTY City,State,Zip: JENSEN BEACH,FL, Permit Number:1706-0498 Owner: SIMMERMACHER Jurisdiction: Design Location: FL, Fort Pierce County:: ST.LUCIE COUNTY(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(5065.5 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=20.0 4729.50 ft2 b.Frame-Wood, Exterior R=19.0 233.33 ft2 3. Number of units,if multiple family 1 c. Frame-Wood,Adjacent R=19.0 102.67 ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (2155.0 sqft.) Insulation Area a.Roof Deck(Unvented) R=22.0 2155.00 ft2 6. Conditioned floor area above grade(ft2) 4977 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(886.7 sqft.) Description Area a.Sup:Attic, Ret:Attic,AH:Attic 6 475 a. U-Factor: Dbl, U=0.60 498.44 ft2 b.Sup: Attic,Ret:Attic,AH:Attic 6 425 SHGC: SHGC=0.20 b. U-Factor: Dbl, U=0.65 378.94 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a.Central Unit 58.5 SEER:16.50 c. U-Factor: Dbl, U=0.40 9.33 ft2 b.Central Unit 48.0 SEER:17.00 SHGC: SHGC=0.20 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Strip Heat 34.0 COP:1.00 SHGC: b.Electric Strip Heat 34.0 COP:1.00 Area Weighted Average Overhang Depth: 6.275 ft. - -Area Weighted Average SHGC: 0.221 14.Hot water systems 8. Floor Types (2175.5 sqft.) Insulation Area a.Electric Cap:80 gallons a.a.Raised Floor R=19.0 1350.50 ft2 b. Conservation features b.Slab-On-Grade Edge Insulation R=0.0 825.00 ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.178 Total Proposed Modified Loads: 139.17 PASS Total Baseline Loads: 156.74 I hereby certify that the plans and specifications covered by Review of the plans and O�VE Sro this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance 76) with the Florida Energy Code. PREPA D Y: Before construction is completed r� DATE: this building will be inspected for compliance with Section 553.908 * � I hereby certify that this building desi ed, is in compliance Florida Statutes. !� y� with the Florida Energy Co G'QD wt OWNER/AGENT: BUILDING OFFICIAL: DATE: 3 G DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. FILE" COPY 8/1/2017 9:35 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 7 I FORM R405-2014 PROJECT Title: SIMMERMACHER RESIDEN Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 4977 Lot# Owner: SIMMERMACHER Total Stories: 3 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: COASTAL CONSTRUCTION Rotate Angle: 0 Street: 7912 S.OCEAN DRIVE Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: ST.LUCIE COUNTY Jurisdiction: Whole House Fan: No City,State,Zip: JENSEN BEACH, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL_VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Vo lume 1 AHU#1 2926 31245.4 2 AHU#2 2051 20510 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 DINING 249 2938.2 No 2 1 No Yes Yes 2 FOYER 266 2660 No 0 1 No Yes Yes 3 POWDER 70 756 No 0 1 No Yes Yes 4 A/C CLST. 28 302.4 No 0 1 No Yes Yes 5 STAIRS 138 1490.4 No 0 1 No Yes Yes 6 KITCHEN 252 2721.6 Yes 0 1 No Yes Yes 7 LIVING ROOM 398 4696.4 No 2 1 No Yes Yes 8 MEDIA ROOM 304 3283.2 No 0 1 No Yes Yes 9 BATH 77 831.6 No 0 1 No Yes Yes 10 CLST. 35 378 No 0 1 No Yes Yes 11 MAIDS QUARTER 284 3067.2 No 2 1 1 No Yes Yes 12 EXERCISE 378 3780 No 4 1 Yes Yes Yes 13 LOWER FOYER 180 1692 No 0 1 No Yes Yes 14 ELEV 36 338.4 No 0 1 No Yes Yes 15 CABANA 69 690 No 0 1 No Yes Yes 16 STOR. 162 1620 No 0 1 No Yes Yes 17 OFFICE 272 2720 No 0 1 No Yes Yes 18 GUESTBATH 78 780 No 0 1 No Yes Yes 19 WIC 42 420 No 0 1 No Yes Yes 20 GUEST SUITE 176 1760 No 0 1 1 No Yes Yes 21 LAUNDRY 105 1050 No 0 1 No Yes Yes 8/1/2017 9:35 AM EnergyGaugeg)USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 7 FORM R405-2014 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 22 AHU 2 CLST. 25 250 No 0 1 No Yes Yes 23 SITTING 191 1910 No 0 1 No Yes Yes 24 LOFT 369 3690 No 0 1 No Yes Yes 25 MASTER SUITE 383 3830 No 0 1 1 No Yes Yes 26 W.I.C. 56 560 No 0 1 No Yes Yes 27 WIC 2 45 450 No 0 1 No Yes Yes 28 MASTER BATH 271 2710 No 0 1 No Yes Yes 29 TOILET 38 380 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Raised Floor DINING _--- ___- 249 ft2 19 0 0 1 2 Raised Floor DINING ---- __-- 16 ft2 19 0 1 0 3 Raised Floor FOYER ---- ---- 122 ft2 19 0 0 1 4 Raised Floor POWDER __-- ---- 70 ft2 19 0 0 1 5 Raised Floor A/C CLST. ---- ____ 28 ft2 19 0 0 1 6 Raised Floor STAIRS ---- ---- 28 ft2 19 0 0 1 7 Raised Floor KITCHEN ---- ---- 61 ft2 19 0 1 0 8 Raised Floor LIVING ROOM _--- ---- 24 ft2 19 0 0 1 9 Raised Floor MEDIA ROOM _--- __-- 304 ft2 19 0 0 1 10Raised Floor BATH --- ---- 77 ft2 19 0 0 1 11Raised Floor CLST. ___- ---- 35 ft2 19 0 0 1 12Raised Floor MAIDS QUARTE ---- ---- 234 ft2 19 0 0 1 13Raised Floor MAIDS QUARTE ---- ---- 50 ft2 19 0 1 0 14Slab-On-Grade Edge Insulatio EXERCISE 1 ft 0 378 ft2 ---- 0 1 0 15SIab-On-Grade Edge Insulatio LOWER FOYER 1 ft 0 180 ft2 _--- 0 1 0 16SIab-On-Grade Edge Insulatio ELEV 1 ft 0 36 ft2 ---- 0 1 0 17SIab-On-Grade Edge Insulatio CABANA 17 ft 0 69 ft2 ---- 0 1 0 18SIab-On-Grade Edge Insulatio STOR. 15 ft 0 162 ft2 ---- 0 1 0 19Raised Floor OFFICE ---- ---- 20 ft2 19 0 1 0 20Raised Floor MASTER BATH ---- ---- 1.5 ft2 19 0 1 0 21Raised Floor TOILET ---- ---- 31 ft2 19 0 1 0 8/1/2017 9:35 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 7 FORM R405-2014 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Flat tile/slate 2271 ft2 358 ft2 Light 0.6 No 0.9 No 22 18.4 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Unvented 0 2155 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Unvented) DINING 22 Blown 16 ft2 0.1 Wood 2 Under Attic(Unvented) MEDIA ROOM 22 Blown 18 ft2 0.1 Wood 3 Under Attic(Unvented) BATH 22 Blown 7 ft2 0.1 Wood 4 Under Attic(Unvented) MAIDS QUARTE 22 Blown 63 ft2 0.1 Wood 5 Under Attic(Unvented) OFFICE 22 Blown 272 ft2 0.1 Wood 6 Under Attic(Unvented) GUESTBATH 22 Blown 78 ft2 0.1 Wood 7 Under Attic(Unvented) WIC 22 Blown 42 ft2 0.1 Wood 8 Under Attic(Unvented) GUEST SUITE 22 Blown 176 ft2 0.1 Wood 9 Under Attic(Unvented) LAUNDRY 22 Blown 105 ft2 0.1 Wood 10 Under Attic(Unvented) AHU 2 CLST. 22 Blown 25 ft2 0.1 Wood 11 Under Attic(Unvented) SITTING 22 Blown 191 ft2 0.1 Wood 12 Under Attic(Unvented) LOFT 22 Blown 369 ft2 0.1 Wood 13 Under Attic(Unvented) MASTER SUITE 22 Blown 383 ft2 0.1 Wood 14 Under Attic(Unvented) W.I.C. 22 Blown 56 ft2 0.1 Wood 15 Under Attic(Unvented) WIC 2 22 Blown 45 ft2 0.1 Wood 16 Under Attic(Unvented) MASTER BATH 22 Blown 271 ft2 0.1 Wood 17 Under Attic(Unvented) TOILET 22 Blown 38 ft2 0.1 Wood WALLS Adjacent Cavity ity Width Height Sheathing Framing Solar Below 1 le Et In Et In Amn R-NIalue G N Exterior Concrete Block-Int Insul DINING 20 15 0 11 10 177.5 ft2 0 0 0.5 0 2 S Exterior Concrete Block-Int Insul DINING 20 7 0 11 10 82.8 ft2 0 0 0.5 0 3 W Exterior Concrete Block-Int Insul DINING 20 18 0 11 10 213.0 ft2 0 0 0.5 0 4 SW Exterior Concrete Block-Int Insul FOYER 20 4 3 10 0 42.5 ft2 0 0 0.5 0 5 W Exterior Concrete Block-Int Insul FOYER 20 14 0 10 0 140.0 ft2 0 0 0.5 0 6 NW Exterior Concrete Block-Int Insul FOYER 20 4 3 10 0 42.5 ft2 0 0 0.5 0 7 N Exterior Concrete Block-Int Insul STAIRS 20 12 0 10 10 130.0 ft2 0 0 0.5 0 8 N Exterior Concrete Block-Int InsulKITCHEN 20 14 0 10 10 151.7 ft2 0 0 0.5 0 9 E Exterior Concrete Block-Int InsulKITCHEN 20 18 0 10 10 195.0 ft2 0 0 0.5 0 10 E Exterior Concrete Block-Int InstdVING ROO 20 22 0 11 10 260.3 ft2 0 0 0.5 0 11 E Exterior Concrete Block-Int InsWEDIA ROO 20 16 0 10 10 173.3 ft2 0 0 0.5 0 12 S Exterior Concrete Block-Int InsWEDIA ROO 20 19 0 10 10 205.8 ft2 0 0 0.5 0 8/1/2017 9:35 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 7 FORM R405-2014 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 13 S Exterior Concrete Block-Int Insul BATH 20 7 0 10 10 75.8 ftz 0 0 0.5 0 14 N Exterior Concrete Block-Int InsWAIDS QUA 20 9 0 10 10 97.5 ftz 0 0 0.5 0 15 S Exterior Concrete Block-Int InsWAIDS QUA 20 17 0 10 10 184.2 ftz 0 0 0.5 0 16 W Exterior Concrete Block-Int InsLMAIDS QUA 20 18 0 10 10 195.0 ftz 0 0 0.5 0 17 N Exterior Concrete Block-Int Insul CABANA 20 10 0 10 0 100.0 ftz 0 0 0.5 0 18 E Exterior Concrete Block-Int Insul CABANA 20 7 0 10 0 70.0 ftz 0 0 0.5 0 19 N Exterior Concrete Block-Int Insul STOR. 20 9 0 10 0 90.0 ftz 0 0 0.5 0 _20 E Exterior Concrete Block-Int Insul STOR. 20 6 0 10 0 60.0 ftz 0 0 0.5 0 _21 N Exterior Concrete Block-Int Insul OFFICE 20 15 0 10 0 150.0 ftz 0 0 0.5 0 _22 E Exterior Concrete Block-Int Insul OFFICE 20 20 0 10 0 200.0 ftz 0 0 0.5 0 23 S Exterior Concrete Block-Int Insul OFFICE 20 1 0 10 0 10.0 ftz 0 0 0.5 0 _24 N Exterior Concrete Block-Int InsGUESTBATH 20 13 0 10 0 130.0 ftz 0 0 0.5 0 _25 N Exterior Concrete Block-Int Insul WIC 20 7 0 10 0 70.0 ftz 0 0 0.5 0 _26 W Exterior Concrete Block-Int Insul WIC 20 6 0 10 0 60.0 ftz 0 0 0.5 0 _27 S Exterior Concrete Block-Int InsGUEST SUIT 20 5 0 10 0 50.0 ftz 0 0 0.5 0 _28 SW Exterior Concrete Block-Int Ins(DUEST SUIT 20 4 3 10 0 42.5 ftz 0 0 0.5 0 _29 W Exterior Concrete Block-Int InsGUEST SUIT 20 12 0 10 0 120.0 ftz 0 0 0.5 0 _30 E Exterior Concrete Block-Int Insul SITTING 20 16 0 10 0 160.0 ftz 0 0 0.5 0 _31 N Exterior Concrete Block-Int Insul LOFT 20 5 0 10 0 50.0 ftz 0 0 0.5 0 _32 W Exterior Concrete Block-Int Insul LOFT 20 12 0 10 0 120.0 ftz 0 0 0.5 0 _33 E Exterior Concrete Block-Int InsMASTER SUI 20 19 0 10 0 190.0 ftz 0 0 0.5 0 _34 S Exterior Concrete Block-Int InsMASTER SUI 20 17 0 10 0 170.0 ftz 0 0 0.5 0 _35 S Exterior Concrete Block-Int Insul W.I.C. 20 8 0 10 0 80.0 ftz 0 0 0.5 0 _36 N Exterior Concrete Block-Int InsMASTER BA 20 1 0 10 0 10.0 ftz 0 0 0.5 0 _37 S Exterior Concrete Block-Int InsUASTER BA 20 14 0 10 0 140.0 ftz 0 0 0.5 0 _38 W Exterior Concrete Block-Int InsUASTER BA 20 16 0 10 0 160.0 ftz 0 0 0.5 0 _39 N Exterior Concrete Block-Int Insul TOILET 20 7 0 10 0 70.0 ftz 0 0 0.5 0 _40 W Exterior Concrete Block-Int Insul TOILET 20 6 0 10 0 60.0 ftz 0 0 0.5 0 _41 N Garage Frame-Wood LOWER FOY 19 11 9 4 102.7 ftz 0.23 0.6 0 _42 S Exterior Frame-Wood EXERCISE 19 25 9 4 233.3 ftz 0.23 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Insulated FOYER None .39 6 8 48 ftz 8/1/2017 9:35 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 7 FORM R405-2014 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 1 Metal Low-E Double Yes 0.65 0.25 27.2 ft2 2 ft 0 in 12 ft 0 in None None 2 W 3 Metal Low-E Double Yes 0.4 0.2 4.7 ft2 2 ft 0 in 12 ft 0 in None None 3 W 3 Metal Low-E Double Yes 0.65 0.25 27.1 ft2 2 ft 0 in 12 ft 0 in None None 4 W 5 Metal Low-E Double Yes 0.65 0.25 6.0 ft2 6 ft 0 in 1 ft 4 in None None 5 N 8 Metal Low-E Double Yes 0.6 0.2 27.2 ft2 2 ft 0 in 12 ft 0 in None None 6 E 9 Metal Low-E Double Yes 0.65 0.25 27.1 ft2 2 ft 0 in 12 ft 0 in None None 7 E 10 Metal Low-E Double Yes 0.6 0.2 144.0 ft2 10 ft 0 in 1 ft 4 in None None 8 E 11 Metal Low-E Double Yes 0.6 0.2 108.0 ft2 10 ft 0 in 1 ft 4 in None None 9 S 12 Metal Low-E Double Yes 0.65 0.25 11.2 ft2 2 ft 0 in 12 ft 0 in None None 10 S 13 Metal Low-E Double Yes 0.65 0.25 5.6 ft2 2 ft 0 in 12 ft 0 in None None 11 S 15 Metal Low-E Double Yes 0.65 0.25 11.3 ft2 2 ft 0 in 12 ft 0 in None None 12 W 16 Metal Low-E Double Yes 0.4 0.2 4.7 ft2 2 ft 0 in 12 ft 0 in None None 13 W 16 Metal Low-E Double Yes 0.6 0.2 27.2 ft2 2 ft 0 in 12 ft 0 in None None 14 E 18 Metal Low-E Double Yes 0.65 0.25 24.0 ft2 2 ft 0 in 1 ft 4 in None None 15 N 21 Metal Low-E Double Yes 0.65 0.25 23.3 ft2 2 ft 0 in 1 ft 4 in None None 16 E 22 Metal Low-E Double Yes 0.65 0.25 35.0 ft2 2 ft 0 in 1 ft 4 in None None 17 N 24 Metal Low-E Double Yes 0.65 0.25 7.3 ft2 2 ft 0 in 1 ft 4 in None None 18 W 29 Metal Low-E Double Yes 0.65 0.25 40.0 ft2 1 ft 1 in 1 ft 4 in None None 19 E 30 Metal Low-E Double Yes 0.6 0.2 96.0 ft2 10 ft 0 in 1 ft 4 in None None 20 N 31 Metal Low-E Double Yes 0.65 0.25 7.3 ft2 2 ft 0 in 1 ft 4 in None None 21 W 32 Metal Low-E Double Yes 0.65 0.25 48.0 ft2 8 ft 0 in 1 ft 4 in None None 22 E 33 Metal Low-E Double Yes 0.6 0.2 96.0 ft2 10 ft 0 in 1 ft 4 in None None 23 S 34 Metal Low-E Double Yes 0.65 0.25 20.0 ft2 2 ft 0 in 1 ft 4 in None None 24 S 37 Metal Low-E Double Yes 0.65 0.25 18.7 ft2 2 ft 0 in 1 ft 4 in None None 25 W 38 Metal Low-E Double Yes 0.65 0.25 40.0 ft2 1 ft 1 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 1404 ft2 1404 ft2 44 ft 9.4 ft 19 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000463 6038.1 331.49 623.41 .4695 7 8/1/2017 9:35 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 7 FORM R405-2014 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COP:1 34 kBtu/hr 1 sys#1 2 Electric Strip Heat None COP:1 34 kBtu/hr 2 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 16.558.5 kBtu/hr cfm 0.7 1 sys#1 2 Central Unit Split SEER: 17 48 kBtu/hr cfm 0.7 2 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 80 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ftz DUCTS / ----Supply-- --Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 475 ft2 Attic 105 ftz Default Leakage Attic (Default) (Default) 1 1 2 Attic 6 425 ftZ Attic 105 ftz Default Leakage Attic (Default) (Default) 2 2 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Coolin Jan Feb Mar A r Ma X Jun Jul rj Au Se Oct Nov Dec Heating lX�Jan X Feb Xj Mar Apr f May4 Jun 4 Jul Au1XI Sep Oct H Nov Dec Ventin [ ]]]Jan [I Feb [X Mar [X A r [ Ma [ Jun [ Jul Aug Se [X]Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 8/1/2017 9:35 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 7 of 7 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: SIMMERMACHER RESIDENCE Builder Name: COASTAL CONSTRUCTION Street: 7912 S.OCEAN DRIVE Permit Office: ST.LUCIE COUNTY City,State,Zip: JENSEN BEACH, FL, Permit Number:1706-0498 Owner: SIMMERMACHER Jurisdiction: Design Location: FL,Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/doorjambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 8/1/2017 9:35 AM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 89 The lower the EnergyPerformance Index, the more efficient the home. 7912 S. OCEAN DRIVE, JENSEN BEACH, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=20.0 4729.50 ft2 b.Frame-Wood,Exterior R=19.0 233.33 ft2 3. Number of units, if multiple family 1 c.Frame-Wood,Adjacent R=19.0 102.67 ft2 4. Number of Bedrooms 3 d.N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? No a.Roof Deck(Unvented) R=22.0 2155.00 ft2 6. Conditioned floor area(ft2) 4977 b.N/A R= ft2 7. Windows" Description Area c.N/A R= ft2 a. U-Factor: Dbl,U=0.60 498.44 ft2 11.Ducts R ft2 a.Sup:Attic,Ret:Attic,AH:Attic 6 475 SHGC: SHGC=0.20 b.Sup: Attic, Ret:Attic,AH:Attic 6 425 b. U-Factor: Dbl, U=0.65 378.94 ft2 SHGC: SHGC=0.25 12.Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl, U=0.40 9.33 ft2 a.Central Unit 58.5 SEER:16.50 SHGC: SHGC=0.20 b.Central Unit 48.0 SEER:17.00 d. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency a.Electric Strip Heat 34.0 COP:1.00 Area Weighted Average Overhang Depth: 6.275 ft. b.Electric Strip Heat 34.0 COP:1.00 Area Weighted Average SHGC: 0.221 8. Floor Types Insulation Area 14.Hot water systems Cap:80 gallons a.Raised Floor R=19.0 1350.50 ft2 a.Electric EF:0.97 b.Slab-On-Grade Edge Insulation R=0.0 825.00 ft2 c.N/A R= ft2 b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building T�iE ST Construction through the above energy saving features which will be installed (or exceeded) �Ot , in this home before final inspection. Otherwise, a new EPL Display Card will be completed y4;",,,,°''�' •_ + based on installed Code co liant atures. �r Builder Signature: Date: �i��� 7h, a° Address of New Home: 79/Z s c4c.41�, �� City/FL Zip: ✓�/�SUi� �.CpD 3 y g s� WE *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 8/1/2017 9:35 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 Pro Summa Job: wrightsoft® AH�#� � Date: Jun 26,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM Prosect Information For: SIMMERMACHER LOT#4 7912 S. OCEAN DRIVE, JENSEN BEACH, FL 34957 Notes: Desiqn Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 17126 Btuh Structure 31918 Btuh Ducts 8367 Btuh Ducts 5815 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 25493 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 35846 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 7067 Btuh Ducts 4876 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area 2927 2927 Equipment latent load 11943 Btuh Volumee�ft3) 31257 31257 Air changes/hour 0.26 0.14 Equipment total load 47790 Btuh Equiv.AVF(cfm) 137 73 Regtotal capacity at 0.70 SHR 4.3 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade Trade Model Cond 24ANB76000030 AHRI ref Coil FV4CNB006 AHRI ref 0 Efficiency 100 EFF Efficiency 13.4 EER, 16.5 SEER Heating Input 10.0 kW Sensible cooling 40950 Btuh Heating output 34121 Btuh Latent cooling 17550 Btuh Temperature rise 16 OF Total cooling 58500 Btuh Actual air flow 1950 cfm Actual air flow 1950 cfm Air flow factor 0.076 cfm/Btuh Air flow factor 0.052 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.76 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. c wri htsoft• 7- ° -' o . 41 r 9 Right-Suite®Universal 2017 17.0.14 RSU08101ILL fR.c.P. ...lcs\Documents\SIMMERMACHER RESIDENCE-LOT$3.rup Calc=MJ8 Front Door faces: W ge 1 I • Job: wrightsoft® Project Summary Date: Jun 26,2017 AHU#2 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM Proiect Information For: SIMMERMACHER LOT#4 7912 S. OCEAN DRIVE, JENSEN BEACH, FL34957 Notes: Desiqn Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 13377 Btuh Structure 24482 Btuh Ducts 5965 Btuh Ducts 4147 Btuh Central vent (0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 19342 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 27198 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2337 Btuh Ducts 3459 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 2050 2050 Equipment latent load 5797 Btuh Volume(ft') 20495 20495 Air changes/hour 0.31 0.16 Equipment total load 32994 Btuh Equiv.AVF (cfm) 104 56 Req. total capacity at 0.70 SHR 3.2 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade Trade CARRIER Model Cond 24AN B748AO031 AHRI ref Coil FV4CNB006 AHRI ref 5634911 Efficiency 100 EFF Efficiency 13.5 EER, 17 SEER Heating Input 10.0 kW Sensible cooling 33600 Btuh Heating output 34121 Btuh Latent cooling 14400 Btuh Temperature rise 19 OF Total cooling 48000 Btuh Actual air flow 1600 cfm Actual air flow 1600 cfm Air flow factor 0.083 cfm/Btuh Air flow factor 0.056 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.83 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - wri htsoft® 2017-Aug-01 08:52:41 g Right-Suite®Universal 2017 17.0.14 RSU08101 Page 2 ...IcslDocumentsMMMERMACHER RESIDENCE-LOT$3.rup Calc=MJ8 Front Doorfaces: W wri htsoft° Ri h -M)Worksheet Job: 9 AHU#1 Date: Jun 26,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@,AOL.COM 1 Room name AHU#1 DINING 2 Exposed wall 247.4 ft 40.0 ft 3 Room height 10.7 ft d 11.8 ft heat/cool 4 Room dimensions 1.0 x 250.0 ft 5 Room area 2927.0 ft' 250.0 ft' Ty Construction U-value Or HTM Area (ft2) Load Area (ft� Load number (Btuh/ft;°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Tailored foam inject 0.000 n 0.00 T 0.00 547 519 0 0 83 83 0 0 4A5-2ov 0.470 n 13.16 13.55 28 0 368 379 0 0 0 0 . 'E 4A5-2ov 0.470 n 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov .---.--- - ----0.470 _n. 0.00. 0.00 .,--'0 --- -0 --0 ---- - 0 -. 0- --0 -- 0 0 11 W_ _- -- Tailored foam inject___ . 0.000 _ne, _ 0.00 _ 0.00 _ . 42 ._ 42 0 0 -0- - -_ 0 0 _ - 0 Tailored foam inject 0.000 a 0.00 0.00 547 429 0 0 212 161 0 0 1D-c2ovd 0.570 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 e_ 13.16 36.84 9 0 123 344 5 0 61 172 4A5-2ov 0.470 a 13.16- 13.55 6 6 79 81 0 0 0 0 4A5-2ov 0.470 a 13.16 36.84 54 0 712 1994 27 0 356 997 4A5-2ovd ' 0.470 a 0.00 0.00 0 0 0 0 0 0 0 0 _ _-11DO _ 0.390 a 10.92 _ 11.31 - ___ 48, 48 _524 . _ 543 0 0.-- _ 0 ____ _ W Tailored foam inject_ ____0.000_se_ _ 0 Tailoredfoaminject 0.000 s 0.00 0.00 745 691 0 0 177 150 0 0 4A5-2ov 0.470 s 0.00 0.00 0 0 0 0 0' 0 0 0 4A5-2ov 0.470 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov -----_ _ ---_0.470 s _ _.13.16._ _13.55 __ -__54 .- 54 712 -- - 733--_ - 27- - -27--_ -356_- _ 367 Tailored foam inject 0.000 w 0.00 0.00 757 454 0 0 0 0 0 0 1 D-c2ov 0.570 w 0.00 0.00 0 0 0 0 0 0 0 0 1 D-c2ov 0.570 w 15.96 29.64 108 84 1724 3201 0 0 0 0 1Dc2ov 0.570 w 15.96 29.64 144 112 2298 4268 0 0 0 0 1 Dc2cvd 0.570 w 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 w 13.16 36.84 27 0 356 997 0 0 0 0 4A5.2ov _ 0.470 w 13.16 35.79 24 1 316 859 0 0 0 0 R 12C-0sw -0.091 - 2.55 1.28 -690 666 1697 855 0- 0 0 0 D-11D0 w ,-_- 0390, n- _10.92 11.31- _ ._ 24 _.- 24 _262 _. -_ 271 _---. _ 0 ---- .0 _ 0 R 12E-0sw 0.068 - 1.90 0.78 730 706 1344 552 0 0 0 0 L -D 11 D0__- 0.390-__n- 10.92 11.31 24 _ _ _ 24 _262_ 271 - - 0 _. 0 __ 0 0 - - C 76X19Omd _ _-0.408 __ - ._ 1.69 1.49 _ - 105 _ _._ 105 __. 166_ 156 16 16 _._ _ 25 _-. 24 F.„._. 19C-19csco _ 0.049 - 0.48-__ 0.25_ _ 1156 _ 1156 _ _550 _ 295_, 234 234 _- 'I'll 60 F - 22A"tpl- =- -0.989... 27.69---0.00 - -825- 33 914 _ _. 0_ .. 0 0 - 0 F, 22A-tol _ , 27,-. 18 . . .-_500 0_. 16 3 71 0.989. 27,69 0.00 1- . 0 6 c)AED excursion 10607 -110 Envelope loss/gain 12909 26408 981 1510 12 a) Infiltration 4218 1210 743 213 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 10 2300 2 460 Appliances/other 2000 0 Subtotal(lines 6 to 13) 17126 31918 1724 2183 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 2 1 14 Subtotal 17126 31918 1727 2184 15 Duct loads 49% 18% 8367 5815 49% 18% 843 398 Total room load 25493 37733 2570 2582 Air required(cfm) 19501 19501 197 133 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .4C�A -`-F wrigtrtsoft• 2017-Aug-01 08:52:41 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 1 ..lcs\Documents\SIMMERMACHER RESIDENCE-LOT$3.rup Calc=MJ8 Front Door faces: W _ I •wri htsoft Ri h -M)Worksheet Job: 9 AHU#1 Date: Jun 26,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772466-6796 Email:QUICKCALCS@,AOL.COM 1 Room name FOYER POWDER 2 Exposed wall 22.4 ft 0 ft 3 Room height 10.0 ft heat/cool 10.8 ft heat/cool 4 Room dimensions 1.0 x 266.0 ft 7.0 x 10.0 ft 5 Room area 266.0 ft2 70.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Tailored foam inject 0.000 n 0.00 0.00 0 0 0 0 0 6 0 0 4A5-2ov 0.470 n 13:16, 13.55 0 0 0 0 0 0 0 0 4A5-2ov .0.470 n 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov _ _-- _--- ____O.470 _n- _ - 0.00-:__.__0.00 - _._0 0 _0 ­_0 _ _- _0---- - 0_ ---_- Q -. _. ._0 11 W _ Tailored_foam_inject _ _ 0.000 ne_ 0.00 _- 0.00 _.__42 -_ 42_ _ _ 0 _ 0 0 __ 0 Tailored foam inject 0.000 a 0.00 0.00 140 86 0 0 0 0 0 0 1 D-c2ovd 0.570 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 a 13.16 36.84 0 0 0 0 0 0 0 0 4A5-2ov 0.470 a 13.16 -13.55 6 6 79 81 0 0 0 0 4A5-2ov 0.470 'e 13.16 36.84 0 0 0 0 0 0 0 0 4A5-2ovd 0.470 a 0.00 0.00 0 0 0 0 0 0 0 0 11 DO 1 _ ___ 0.390 _e_ _ 10.92 11.31 ._ 48 _ 48 _ .- _524 543- 0 _._. 0 - -0 0 W Tailored foam inject 0.000 se 0.00 0.00 42 42 0 0 0 0 0 0 Tailored foam inject 0.000 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 s. 0.00 ` 0.00 0 0 0 0 0 0 0 0 --G 4A5-2ov 0.470 s 0.00 0.00 0 0 0 0 0 0 0 0 _�- 4A5-2ov -:.__. __ _O.470 s- 13.16_ 13.55 0_ 0 _O _ 0 0 _ _ 0 __ 0 0 Tailored foam inject 0.000 w 0.00 0.00 0 0 0 0 0 0 0 0 1 D-c2ov 0.570 w 0.00 0.00 0 0 0 0 0 0 0 0 1 D-c2ov 0.570 w 15.96 29.64 0 0 0 0 0 0 0 0 1 D-c2ov 0.570 w 15.96 29.64 0 0 0 0 0 0 0 0 1D-c2ovd 0.570 w 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 w 13.16 36.84 0 0 0 0 0 0 0 0 4A5-2ov--, _ _ 0.470 _w_ _13.16__ 35.79 0 0 _ 0 _ -0- 0 _ _ 0 0 _ 0 R 12C-Osw 0.001 2.55 1.28 0 6 0 0 0 0 0 0 D 11DO__--. ----- -- -- 0.390._n_. 10.92 _. 11.31 0_.___. _ 0 :__._0 0_-. _. 0. ._ 0 ------ O __.:.0 R 12E-Osw 0.068 - 1.90 0.78 0 0 0 0 6 0 0 0 11DO 0.390 n _ 10.92 11.31 0 0 0 _ 0 0 0 0 0 0.408--- 1.59 - 1.49 0 0 - 0 0_- _ 0 0 _ 0 0 19C-19csco__ _ -049 .__- 0.48.--_0.25 __-122 122 58 _ 31 _.. _ 70 70. - 33 18 F 22A_tpl --------- 0;989 "- 27.69 -0.00 0 0 - - 0 -0 0 - 22A-tDl------ - -- ___-- 0.989 _-_ 27.69- 0.00 0 --- 6 0 0 0 -- 0 __-- 0 6 c)AED excursion -36 -1 Envelope loss/gain 661 619 33 17 12 a) Infiltration 354 102 0 0 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1015 721 33 17 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 4 2 14 Subtotal 1015 721 38 19 15 Duct loads 49% 18% 496 131 49% 18% 18 3 Total room load 1511 852 56 23 Air required(cfm) 116 44 41 1 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wr1 htSOft' 2017-Aug-0108:52:41 .�A 9 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 2 ...Ics\Documents\SIMMERMACHER RESIDENCE-LOT$3.rup Calc=MJ8 Front Door faces: W • wrightsoft9 Ri --J®Worksheet Job: AHU#1 Date: Jun 26,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name A/C CLST. STAIRS 2 Exposed wall 0 ft 12.0 ft 3 Room height 10.8 ft heat/cool 10.8 ft heat/cool 4 Room dimensions 7.0 x 4.0 ft 1.0 x 138.0 ft 5 Room area 28.0 ftz 138.0 ftZ Ty Construction U-value Or HTM Area (ft� Load Area (ftJ Load number (Btuh/W�-°F) (Btuh/ftl or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Tailored foam inject 0.000 n 0.00 0.00 0 - 0 0 0 6 0 0 0 4A5-2ov 0.470 n 13.16 13.55 0 0 0 0 0 0 0 0 G 4A5-2ov 0.470 n 0.00 0.00 0 0 0 0 0 0 0 0 `G: 4A5-2ov. _---•--- -- ------0:470 --n-- - --0.00 0.00 . --- 0 - 0 --0 --0- ----._ 0-_-- 11 W. _ Tailored,foam inject _ _ - 0.000 -ne _ _.0.00, _0.00 _ _ -0 0 __ 0 0 .,. _ 0_ 0 0 _ -.0 Tailored foam inject 0.000 a 0.00 0.00 0 0 0 0 0 0 0 0 1Dc2ovd 0.570 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 a 13.16. 36.84 0 0 0 0 0 0 0 0 4A5-2ov 0.470 a 13.16 13.55 0 0 0 0 0 0 0 0 4A5-2ov 0.470 a 13.16 36.84 0 0 0 0 0 0 0 0 4A5-2ovd 0.470 a 0.00 0.00 0 0 0 0 0 0 0 0 11D0- --- 0.390_a _10.92 11.31- 0 0 ---0 0 0 0- 0 0 W Tailored foam inject _. 0.000_se 0.00 0.00 0 0 0 0 0 0 0 _ 0 Tailored foam inject 0.000 s 0.00 0.00 0 0 -0 0 130 130 0 0 4A5-2ov 0.470 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5.2ov 0.470 s 0.00 0.00 0 0 0 0 0 0 0 0 _ _ 4A5-2ov_.m_ _0.470 .s _13.16 . _13.55 _ _ _ 0 - 0 0_ _ _ 0 .0 __ 0 _ 0 - 0 Tailored foa inject 0.000 w 0.00 0.00 0 0 0 0 0 0 0 0 1 D-c2ov 0.570 w 0.00 0.00 0 0 0 0 0 0 0 0 1Dc2ov 0.570 w 15.95 29.64 0 0 0 0 0 0 0 0 1 Dc2ov 0.570 w 15.96 29.64 0 0 0 0 0 0 0 0 ID-c2ovd 0.570 w 0.00 0.00 0 0 0 0 0 0 0 0 4A5.2ov 0.470 w 13.16 36.84 0 0 0 0 0 0 0 0 4A5-2ov-_ w_.__ 13,16_ -35.79_ _ 0 0 0 0 _ 0_ 0 _ 0 __ 0 12C-0sw 0.091 2.55 1.28 0 0 0 0 0 0 0 0 11D0 __.._ _.- _---_ `0.390-,n-. 10.92__-_11.31 0-__-.-:- 0 . _._. _ 0 _ _ ._ _0 0 0_-- -- R 12E-0sw 0.068 - 1.90 0.78 0 0 0 0 0 0 0 0 11D0 .- -- ._---0.390 -n-- 10.92 ..-11.31 0 0 - 0 _0 0 0 0 - - 0 0.408_- .1.59 -_. 1.49 0 . _ __0-_ _ _ -. 0 _ _0 _ _ 0 0 _- _ 0 F. _ 19C-19cscp __0.049 --0.48 _0.25 28_ 28 13 7 __ 28 _ 28 13 7 F ._ . 22Actpl__.:: ____- -._.0.989 27.69. 0.00. - -0 . -- .F. - 22A-tpl __. 0 _._ _. 0_. _o -_.. . -._ 0 0.: -.--- 0 _o --- -- --0.989 - --27,69 - 0.00 ------- 0 _. 0 --- 0 - 0- - 0 -- 0 -- 0 6 c)AED excursion 0 -3 Envelope loss/gain 13 7 13 4 12 a) Infiltration 0 0 204 59 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 13 7 217 63 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -13 -7 7 3 14 Subtotal 0 0 224 66 15 Duct loads 49% 18% 0 0 49% 18% 109 12 Total room load 0 0 333 78 Air required(cfm) 01 01 1 1 25 4 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrigFltsoft" 2017-Aug-01 08:52:41 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 3 'CC-l` ...Ics%DocumentslSIMMERMACHER RESIDENCE-LOT$3.rup Calc=MJ8 Front Door faces: W I i • wrightsoft° Rig hi J®Worksheet Job: AHU#1 Date: Jun 26,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name KITCHEN LIVING ROOM 2 Exposed wall 32.0 ft 22.0 ft 3 Room height 10.8 ft heat/cool 11.8 ft heat/cool 4 Room dimensions 14.0 x 18.0 ft 1.0 x 398.0 ft 5 Room area 252.0 ft' 398.0 ftz Ty Construction U-value Or HTM Area (ft� Load Area (ft� Load number (Btuh/t;°F) (Btuh/ft� or perimeter (ft) (Stuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Tailored foam inject 0.000 n 0.00 0.00 0 0 0 0 0 0 6 0 4A5-2ov 0.470 n 13.16 13.55 0 0 0 0 0 0 0 0 4A5-2ov 0.470 n 0.00 0.00 0 . 0 0 0 0 0 0 0 4A5-2ov_ -, -_ -_ 0.470 _n. __ .0.00 0.00 __- 0_....- .. _0 _..:0 0 _ _._ 0 0 .. _ 0 11 W- _ Tailored foam_-infect _ _._ -0.000 ne _-- 0.00__--0.00_ _ 0 _ 0 _ 0 0 _ ______0 0 _ 0_ _ _ Tailored foam inject . 0.000 a 0.00 0.00 0 0 -'0 0 0 0 0 0 1Dc2ovd 0.570 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 a 13.16 36.84 0 0 0 0 0 0 0 0 4A5-2ov 0.470 a 13.16- 13.55 0 0 0 0 0 0 0 0 4A5-2ov 0.470 a 13.16 36.84 0 0 0 0 0 0 0 0 4A5-2ovd 0.470 a 0.00 0.00 0 0 0 0 0 0 0 0 11D0_,--____ - 0.390 a 10.92-: 11.31 _ 0.. -0 ___0 0 0 0-- Q-- - - 0 W Tailored foam inject 0.0000 se_ 0.00 0.00 0 0 _0 _ 0 0 0 0 0 Tailored foam inject 0.000 s 0.00_ 0.00 151 124 V _ 0 0 0 0 0 0 4A5-2ov 0.470 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5.2ov- 0.470 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5 2ov _-- - - 0.470 -s- 13.16 _ 13.55 _27 27 356 ._ 367 - -- -0 - -,_0 - 0 0 Tailored foam inject 0.000 w 0.00 0.00 194 167 0 0 260 116 0 0 1Dc2ov 0.570 w 0.00 0.00 0 0 0 0 0 0 0 0 1 D-c2ov 0.570 w 15.96 29.64 0 0 0 0 0 0 0 0 1Dc2ov 0.570 w 15.96 29.64 0 0 0 0 144 112 2298 4268 1D-c2ovd 0.570 w 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 w 13.16 36.84 27 0 356 997 0 0 0 0 4A5-2ov___ _ 0.470 w. _ _13.16 35.79- _____- __ 0 0 0 _ 0__ _ 0 0 0_ 0 12C-0sw 0.091 -- 2.55 1.28 0 0 0 0 0 0 0 6 _-0:11D0 -= - _-_.0.390 -n_-__10.92_-.-11.31 -- - 0 0 - 0 0 -..-0 - 0- - 0 0 P 12E-0sw 0.068 - 1.90 0.78 0 0 0 0 0 0 0 0 L- 11 D0.- _ 0.390 _ n- _ 10.92_ 11.31 _0 _ 0 C _.._ 16X19-0md------- ---0.408 . -- - _1.59 1.49-- - -- 0 - 0 0- -- __0 .0 -- 0 0--- - -Q F -_ 19C-19csc0___.- --_--_ -.--_0 049 - 0.48-.-_ 0.25 0.--- -_ 0 . _. .__0 _ 0 - 24- -- 24 _- 11 .__ - _6 F--- 22A-tpl-_--- - - - 0.989__=- 27.69 _ _0.00 0 -0 -0 0 0 0 6_ 0 -F_ 22A-tDl _ _ __0.989 27.69 0.00 61_ 8- _ - 215 6 c)AED excursion 141 5978 Envelope loss/gain 927 1505 2310 10252 12 a) Infiltration 544 156 408 117 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 2000 0 Subtotal(lines 6 to 13) 1471 3661 2718 10829 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1471 3661 2718 10829 15 Duct loads 49% 18% 718 667 49% 18% 1328 1973 Total room load 2189 4328 1 1 4046 12802 Air required(cfm) 167 224 309 662 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed AC4 wrightsoft" 2017-Aug-01 08:52:41 �A Right-Suited Universal 2017 17.0.14 RSU08101 Page 4 ..Ics\Documents%SIMMERMACHER RESIDENCE-LOT$3.rup Calc=MJ8 Front Door faces: W lh -�J@ wri htsoft° Ri Worksheet Job: A AHU#1 Date: Jun 26,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@40L.COM 1 Room name MEDIA ROOM BATH 2 Exposed wall 35.0 ft 7.0 ft 3 Room height 10.8 ft heat/cool 10.8 ft heat/cool 4 Room dimensions 19.0 x 16.0 ft 7.0 x 11.0 ft 5 Room area 304.0 ftz 77.0 ftZ Ty Construction U-value Or HTM Area (ft� Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Tailored foam inject' 0.000 n -0.00 0.00 205 194 0 0 76 70 0 0 4A5.2ov 0.470 n 13.16 13.55 11 0 147 152 6 0 74 76 4A5-2ov 0.470 n 0.00 0.00 0 0 0 0 0 0 0 0 4A-5-2ov___..-- '----- 0.470.__n .- -_0.00 0.00 ---- -.-0 ..__ _ _0 __-_ 0 _ --0 0 -. -0-- 0 _. _._0 11 _W Tailored foam iniect __._0.000 ne__ .0.00- 0.00"-__. .__0 _ _0 _ 0 _0 _ _ _ 0_ 0 0 _" -0 Tailored foam inject_ 0.000 a 0.00 0.00 0 0 0 0 0 0 0 0 1Dc2ovd 0.570 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5.2ov 0.470 a 13.16 36.84 0 0 0 0 0 0 0 0 4A5-2ov 0:470 a 13.16 13.55 0 0 0 0 0 0 0 0 4A5-2ov 0.470 a 13.16- 36.84 0 0 0 0 0 0 0 0 4A5.2ovd 0.470 a 0.00 0.00 0 0 0 0 0 0 0 0 11D0 -- 0.390 -e _._.10.92 . 11.31 ° ° - 0 - -0 - - ° - 0 - 0. W Tailored foam inject 0.000 se 0.00 0.00 0 0 0 0 0 0 0 0 VVVNNN Tailored foam inject t 0.000 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov _ _ - 0.470 -_s_ 13.16 _ 13.55 0- 0 __._0 _ 0. --.0- 0_ .. _._ ___ -.0 ___ 0 Tailored foam inject 0.000 w 0.00 0.00 173 65 0 0 0 0 0 0 1Dc2ov 0.570 w 0.00 0.00 0 0 0 0 0 0 0 0 1 Dc2ov 0.570 w 15.96 29.64 108 84 1724 3201 0 0 0 0 1 Dc2ov 0.570 w 15.96 29.64 0 0 0 0 0 0 0 0 1Dc2ovd 0.570 w 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 w 13.16 36.84 0 0 0 0 0 0 0 0 4A5-2ov_ _ 0.470 _w_ -_ 13.16_ 35.79 _0 0 12C-0 6 sw 0.091 - 2.55 1.26 0 . 0 0 0 0 6 0 D 11 DO _ _ 0:390.._ n. 10,92.....11.31 ---0 -0- ---.__0 0 -0- - -°-- 0 - 0 R 12E-0sw 0.068 - 1.90 0.78 0 0 0 0 0 0 0 0 11 DO __-__ _ 0.390 n 10.92 _ 11_31 _ 0 0_ 0 0 0 0 0 0 - - C-. 16X19-0md _-_----_----0.408 -_---_:_ 1.59 -.1.49 19 _ 19 .---._-30 28 -.--___-7 _ 7 ._ 11 IQ F_ - 19C_19 _0. csco__ 0_049 0.48 ._ 0.25 30_4 304. --1� ---77 - 77 _ 77 - -37- 20 F - 22A-tpl - -_. 989 27.69 0.00- 21A_tpl -- 0.989. --- 27.69 - 0.00 __ Q -. _0. - - 0 ° - 0 - -0 - ° .. ° 6 c)AED excursion 4449 -7 Envelope loss/gain 2046 7908 121 99 12 a) Infiltration 595 171 119 34 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 2641 8079 240 133 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 S ubtotal 2641 8079 240 133 15 Duct loads 49% 18% 1290 1472 49% 18% 117 24 Total room load 3931 9550 358 158 Air required(cfm) 301 494 27 8 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft" 2017-Aug-01 08:52:41 Right-Suite®Universal 2017 17.0.14 RSU08101'�� ...lcs\Documents%SIMMERMACHER RESIDENCE-LOT$3.rup Calc=MJ8 Front Doorfaces: W Page 5 i wrightsoft° Rig hn -J®Worksheet Job: AHU#1 Date: Jun 26,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772466-6799 Fax:772-466-6796 Email:QUICKCALCS@D40L.COM 1 Room name CLST. MAIDS QUARTERS 2 Exposed wall 0 ft 44.0 ft 3 Room height 10.8 ft heaticool 10.8 ft heat/cool 4 Room dimensions 7.0 x 5.0 ft 1.0 x 284.0 ft 5 Room area 35.0 ftz 284.0 ftz Ty Construction U-value Or HTM Area (ftJ Load Area (ft� Load number (Btuh/ft�°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 . Tailored foam inject 0.000 n 0.00 0.00 - 0 0 0 0 184 in 0 6 4A5-2ov 0.470 n 13.16 13.55 0 0 0 0 11 0 147 152 4A5-2ov 0.470 n 0.00 0.00 0 0 0 0 0 0 0 0 - 4A52oy_". _. -- _.0.470 . n - 0.00.. 0.00 - 0 -_.._. 0 _ -... _0. 0 . 0 0--- 0 - ..-- 0 11 W _._, Tailored foam infect_ 0.000 ne 0.00M_. _0.00 _ _ 0 _0 ______.0 _ 0_ . 0 . _ 0 _ _ . . 0_ 0 Tailored foam inject 0.000 a 0.00 0.00 0 0 0 0 194 163 0 0 1 D-c2ovd 0.570 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 a 13.16 36.84 0 0 0 0 5 0 61 172 4A5-2ov ,. 0.470 a 13.16` 13.55 0 0 0 0 0 0 0 0 4A5-2ov 0.470 a 13.16 36.84 0 0 0 0 27 0 356 997 4A5-2ovd .0.470 a 0.00. 0.00 0 0 0 0 0 0 0 0 11D0 _ 0.390__e_ _ 10.92_ 11.31. _ . .__ 0 0 0 _ _ _0 _ _.0 0 _0 _:__ -0 W Tailored foaminject _ 0.000 se 0.00 0.00 0 0 0 0 0 0 0 ___0 TETailored foam inject 0.000 s 0.00 0.00 0 0 0 0 97 .97 0 _ 0 4A5-2ov 0.470 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5.2ov 0.470 s 0.00 0.00 0 0 0 0 0 0 0 - 0 _ 4A5-2ov___ -_ _ _ 0.470 s 13.16 ___13.55 0 __0 ___ 0 _ -0 -__. 0 _ _ __0.0 0 Tailored foam inject 0.000 w 0.00 0.00 0 0 0 0 0 0 0 0 1 D-c2ov 0.570 w 0.00 0.00 0 0 0 0 0 0 0 0 1Dc2ov 0.570 w 15.96 29.64 0 0 0 0 0 0 0 0 1 Dc2ov 0.570 w 15.96 29.64 0 0 0 0 0 0 0 0 1 D-c2ovd 0.570 w 0.00 0.00 0 0 0 0 0 0 0 0 4A5.2ov 0.470 w 13.16 36.84 0 0 0 0 0 0 0 0 __. 4A572oy__ _ __ _ 0.470 _w_ _ 13.16 _ 35.79 0 0 0 0 0 0 _ 0 0 fl 12C-0sw 0.091 - 2.55 1.28 0 0 0 0 0 0 0 0 -- - 11D0. - -"- - _. :.0.390 ._n- - -10.92;--11.31 .. .. ., .0 . 0 _0_ -- 0.- - -0 0 - -0 P 12E-0sw 0.066 - 1.90 0.78 0 0 0 0 0 0 0 0 _11D0 _ 0.390 -n_ 10.92._ 11.31 0 -_ 0 0 _ 0 0 _ 0 _ 0 0 16X190md __--- _ 0.408 _ 1..59_.-_ 1.49 0 _ .. -0_ .. 63 63 -- 100 - 9,4 19C-19cscp 0.049__- - 0.48 0.25 35 35 17 9 _... 234 234 111 _ _._ 60 . E_=_- 22A-tpl-_-,_- -.._ -_.._0.989 _ . -- 27:69 _- 0.00 _ -_-. 0 0 _ F- 22A-tpl _ -- .- 0.989_ __ 27.69 0.00 - _-__0 _ - _0 0 0 5 8__ . 0 _ _ _ 215 _. _._0 6 c)AED excursion 0 -28 Envelope loss/gain 17 8 991 1446 12 a) Infiltration 0 0 748 215 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal(lines 6 to 13) 17 8 1738 2120 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 17 8 1738 2120 15 Duct loads 1 49% 18% 8 2 49% 18% 849 386 Total room load 25 10 1 2588 2507 Air required(cfm) 2 1 198 130 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft" 2017-Aug-01 08:52:41 Right-Suite®Universal 2017 17.0.14 RSU08101 Ar- p` ...Ics\Documents\SIMMERMACHER RESIDENCE-LOT$3.rup Calc=MJ8 Front Door faces: W Page 6 wri htsoftn Ri f1WJ@ Worksheet Job: 8 Date: Jun 26,2017 14U#7 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772466-6796 Email:QUICKCALCS@,AOL.COM 1 Room name EXERCISE LOWER FOYER 2 Exposed wall 1.0 ft 0 ft 3 Room height 10.0 ft heat/cool 9.4 ft heat/cool 4 Room dimensions 14.0 x 27.0 ft 15.0 x 12.0 ft 5 Room area 378.0 ftz 180.0 ftz Ty Construction U-value Or HTM Area (ft� Load Area (ft� Load number (Btuh/ftz°F) (Btuh/ft or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V Tailored foam inject 0.000 n 0.00 0.00 0 0 0 0 0- 0 0 0 4A5-2ov 0.470 n 13.16 13.55 0 0 0 0 0 0 0 0 4A5-2ov 0.470 n 0.00, 0.00 0 , 0 0 0 0 0 0 0 !� 0 -0 -- 0 - 0 4AFr.2ov.__-._ 0.470,n. - ._ 0.00 _ __0.00 0.__ _ 0 0 0 11 W -_,_ Tailored foam inject- _ __- 0.000 -ne _ __0.00 _ _0.00 0 0 _0 _ _ 0_ _ 0 _ 0 0 _ 0 Tailored foam inject 0.000 a 0.00 0.00 0 0 0 0 0 0 0 0 1Dc2ovd 0:570 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 a 13:16 36.84 0 0 0 0 0 0 0 0 4A5-2ov 0.470 a 13.16 13.55 0 0 0 0 0 0 0 0 4A5-2ov 0.470 a 13.16 36.84 0 0 0 0 0 0 0 0 4A5-2ovd 0.470 a 0.00 0.00 0 0 0 0 0 0 0 0 11DO - . -- 0.390 _e 10.92 -11.31 -- - .0 _ 0 0 0 _ 0 _-- -- 0 _ -0 W Tailored foam inject _ 0.000 _se 0.00 0.00 _0 0 0 0 0 0 0 0 Tailored foam inject 0.000 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5.2ov 0.470 s- 0.00 0.00 0 0 0 0 0 0 0 0 _ - 4A5-2ov-__ .__ -_ 0.470 s 13.16 13.55 _. .,_ -0 _. __ _0 ___0. 0 _. _ _0 _ 0 ._ _ 0 _ Tailored foam inject 0.000 w 0.00 0.60 0 6 6 0 0 0 0 0 1 D-c2ov 0.570 w 0.00 0.00 0 0 0 0 0 0 0 0 1 Dc2ov 0.570 w 15.96 29.64 0 0 0 0 0 0 0 0 1 D-c2ov 0.570 w 15.96 29.64 0 0 0 0 0 0 0 0 1D-c2ovd 0.570 w 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 w 13.16 36.84 0 0 0 0 0 0 0 0 _ 4A5 2ov__ 0.470_w_ 13.16____35.79 -_ __ 0 -_- _._0 _ -0 __0 _. 0 __ _ 0 _ 0_ _ 0 R !__.Ll 12C-Osw 0.091 - 2.55 1.28 0 0 0 6 361 277 705 355_11D0- :_ _ __-_.._0.390.._n_ ___ _10.92-4_-11.31 _ : 0 Q _0- _ -- 0-_.._.. 24 24 __--__262.---__.271 P 12E-Osw 0.068 - 1.90 6.78 730 706 1344 552 0 0 0 0 L--D 11D0__ _ -_-_ 0.390 n_ _ _10.92_ _ 11.31 _ 24 24 262- -_ 271 0 0_ _ _ 0 _ 0 C.._. 16X19-Omd---_._ _ .-__ 0.408 _i_ 1.59_ : 1.49 _ ._ _.0 __ 0 _.0 0- __ ..-0 --- ._0 _- -- -o 0 F-. _ 19C719cgcp_-_ _0.049_--- 0.48- 0.25 _ 0 0 0 0 0 0 0 0 F 22A-tpl.--_-.-- - - 0.989 .r._ _ -27.69-._. _0.00 __._378 1 28 _ 0 180_ _..0 -0 - -� 0.989 . -_ _ 27:69 ._--0.00 _ 0 0 0 0 -0 - -0._. _ 0 6 c)AED excursion -83 -30 Envelope loss/gain 1634 740 967 597 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 4 920 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1634 1660 967 597 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 431 207 14 Subtotal 1634 1660 1398 803 15 Duct loads 49% 18% 798 302 49% 18% 683 146 Total room load 2432 1963 1 1 2082 950 Air required(cfm) 1861 101 159 49 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed wrigF�tsoft� 2017-Aug-01 08:52:41 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 7 ..Ics\Documents%SIMMERMACHER RESIDENCE-LOT$3.rup Calc=MJ8, Front Door faces: W °wri htsoft Ri lJO Worksheet Job: e AHU#1 Date: Jun 26,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772466-6799 Fax:772-466-6796 Email:QUICKCALCS@,AOL.COM 1 Room name ELEV CABANA 2 Exposed wall 0 ft 17.0 ft 3 Room height 9.4 ft heat/cool 10.0 ft heaticool 4 Room dimensions 6.0 x 6.0 ft 1.0 x 69.0 ft 5 Room area 36.0 ft2 69.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-'F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Tailored foam inject 0.000 n 0.00 0.00 0 0 0 0 0 0 0 0 Ub 4A5-2ov 0.470 n 13.16 13.55 0 0 0 0 - 0 0 0 0 4A5-2ov 0.470 n 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov..-:_ - __---._O:-470 n - _ .0.00 __ 0.00 _ -__0. - 0 .- 0 _ -0 ._ - _0 - ---0 ---- 0----- .0 11 W __ Tailored.foam inject _ ----0.000. ne 0.00._ 0.00 _0 0 _0 0 _ 0 0 - 0 Tailored foam inject 0.000. e 0.00 0.00 0 0 0 0 0 0 0 0 1 D-c2ovd 0.570 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 a 13.16 36.84 0 0 0 0 0 0 0 0 4A5-2ov 0.470 a 13.16 13.55 0 0 0 0 0 0 0 0 4A5-2ov 0.470 a 13.16 36.84 0 0 0 0 0 0 0 0 4A5.2ovd 0.470 a 0.00 0.00 0 0 0 0 0 0 0 0 _ 11D0._ ---0.390 a 10.92 _ _11.31 Q_ - _0 _ 0 _ .0 0. 0 0 0 W Tailored foam inject__ 0.000_se___ 000 0.00 0 0 _0 0 0 0 _0 0 Tailored foam inject ---6'000 s -0-.-0'-0 6.00 0 0 100 100 0 0 4A5-2ov 0.470 s 0.00 0.00 0 0 0 0 0 0 0 0 4A5 20v 0.470 s 0.00 0.00 0 0 0 0 0 0 0 0 0.470 -s- _13.16 _ 13.55 _ 0 _ Tailored foam inject 0.000 w 0.00 0.00 0 0 0 0 70 46 0 0 1 D-c2ov 0.570 w 0.00 0.00 0 0 0 0 0 0 0 0 1 D-c2ov 0.570 w 15.96 29.64 0 0 0 0 0 0 0 0 1 D-c2ov 0.570 w 15.96 29.64 0 0 0 0 0 0 0 0 1 Dc2ovd 0.570 w 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 w 13.16 36.84 0 0 0 0 0 0 0 0 4A5-2oy - 0.470 w-_ 13.16 35.79 0 _ _ 0 0 _ 0 24__ 1 316 _ 859 R 12C-Osw 0.091 2.55 1.28 169 169 431 217 0 0 0 0 11D0 - - _. 0.390 n . 10.92 , _11,31. _0 Q ' _-0 - -- .0; -.. -0 0 = 0- -- 0- P 12E-Osw 0.068 - 1.90 0.78 0 0 0 0 0 0 0 0 11D0_-___, -- --_- 0.390 -n _10.92___ 11.31 0 _ 0 _ (:F . _- 16X19-0md---- - -----_0.408 _ 1.59--- 1.49 _ _0 O =-.-9 - 0--- 6 0.-- -0 0 F- 19C-19cscp _ 0.049 _ 0.48 0.25 -0 0 0 0 0 0 0 0 F_ 22A-tpi. 0.969 i_ _...27.69 0.00 _ ._'.36 0 __ . __0 _ "-0---- -69 _ ...__17 _-_ _471, , _ ..__.0 F _ 22A-tol .._ ._0.989 =, 27.69 - 0.00 _ 0 _ _0 0 0 0 _ _ 0 0 0 6 c)AED excursion -10 365 Envelope loss/gain 431 207 787 1224 12 a) Infiltration 0 0 268 77 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 431 207 1054 1301 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -431 -207 0 0 14 Subtotal 0 0 1054 1301 15 Duct loads 49% 18% 0 0 49% 18% 515 237 Total room load 0 0 1569 1538 Air required(cfm) 0 0 1 1 120 79 Calculations approved bV ACCA to meet all requirements of Manual J 8th Ed wrightsof , 2017-Aug-01 08:52:41 Right-Suited Universal 2017 17.0.14 RSU08101 Page 8 ..Ics\Documents\SIMMERMACHER RESIDENCE-LOT$3.rup Calc=MJS Front Doorfaces: W wrii htsoft° Ri h J@ Worksheet Job: 9 /Q V#1 Date: Jun 26,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@,AOL.COM 1 Room name STOR. 2 Exposed wall 15.0 ft 3 Room height 10.0 ft heat/coal 4 Room dimensions 1.0 x 162.0 ft 5 Room area 162.0 ftz Ty Construction U-value Or HTM Area (ft� Load Area Load number (13tuh1ft;°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Tailored foam inject 0.000 n 0.00 0.00 0 0 0 0 4A5-2ov 0.470 n 13.16" 13.55 0 0 0 0 4A5-2ov - 0.470 n 0.00, 0.00 0 0 0 0 4A572ov 0.470 n-- 0.00_-__0.00 .-_'0 0 0. - -0 11 W-,___ Tailoredfoam_iniect - _0.000 _ne - _ 0.00 _0.00 _ _ 0 0 ". _ 0_ _ 0 . Tailored foam inject 0.000 a 0.00 0.00 0 0 0 0 1 D-c2ovd 0.'570 a 0.00 0.00 0 0 0 0 4A5-2ov 0.470 a 13.16 36.84 0 0 0 0 4A5-2ov 0.470 a 13.16- 13.55 0 0 0 0 4A5-2ov 0.470 a 13.16 36.84 0 0 . 0 0 4A5-2ovd 0.470 a 0.00 0.00 0 0 0 0 _ 11D0. _ _- -- _ -_0.390 e._ 10.92 __11.31 _-- 0 ., -- 0 _ Q 0 W- Tailored foam inject_ 0:000 se 0.00 _ 0.00 0 __ 0 0 0 Tailored foam inject 0.000 s' 0.00 .0.00 90 90 0 0 - 4A5.2ov 0.470 s 0.00 0.00 0 0 0 0 4A5-2ov 0.470 s 0.00 0.00 0 0 0 0 AA5-2ov ___0.470 -s- 13.1.6 _ 13.55 -_ _ _ _0 . .___ 0 _ _ 0 __ __0 Tailored foam inject 0.000 w 0.00 0.00 60 60 0 0 1 D-c2ov 0.570 w 0.00 0.00 0 0 0 0 1 D-c2ov 0.570 w 15.96 29.64 0 0 0 0 1 D-c2ov 0.570 w 15.96 29.64 0 0 0 0 1Dc2ovd 0.570 w 0.00 0.00 0 0 0 0 4A5-2ov 0.470 w 13.16 36.84 0 0 0 0 4A5-2ov _ _ 0.470 w 13.16 __.35.79- 0 _ 0 -__.____0 0 F1 12C-0sw 0.091 - 2.55 1.28 220 220 561 282 - �-D 11D0._ - - 0,390 _:n 10.92 _.._11.31.---- 0 .- _ ..Q _. ____'0 _0 _ R 12E-0sw 0.068 - 1.90 0.78 0 0 0 0 _11D0 _ 0.390 ,n 10.92 11.31_ ._ - 0. _ 0 0_ 0 C - 1.6X19Omd---- --..--0.408 --1.59 _1.49 0 - 0 0 0 - - F__ 19C-19CScp_ -__ 0.049 - 0.48 ...._ 0.25 ----,0 0 -0 0 F: . _. -224-tpl" --- -- ..._0.989 _27.69 0.00 _:__ 162 .. 15 _ 415. - .0 F. - 22A-tpl._. .__. _0.989 - 27.69 .._.0.00 0 - 0 6 c)AED excursion -17 Envelope loss/gain 976 266 12 a) Infiltration 236 68 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal(lines 6 to 13) 1212 333 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 1212 333 15 Duct loads 49% 18% 592 61 Total room load 1804 394 Air required(cfm) 138 20 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsc2ft- 2017-Aug-01 08:52:41 ACCkRight-Suite®Universal 2017 17.0.14 RSU08101 Page 9 ...lcs%Documents\SIMMERMACHER RESIDENCE-LOT$3.rup Cale=MJ8 Front Door faces: W wri9 htsoft° Rig tli-J®Worksheet Job: AHU#2 Date: Jun 26,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name AHU#2 OFFICE 2 Exposed wall 204.1 ft 36.0 ft 3 Room height 10.0 ft d 10.0 ft heat/cool 4 Room dimensions 1.0 x 272.0 ft 5 Room area 2049.5 ft2 272.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2.-*F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 L� Tailored foam inject 0.000 n 0.00 0.00 450 411 0 0 10 10 6 0 4A5-2ov 0.470 n 0.00 0.00 0 0 0 0 0 0 0 0 4A5 2ov 0.470 n 13.16 , 13.55 19 0 246 253 0 0 0 0 4A5 2ov --_. - -:--- _0.470..n -:.13.16 -_13.55 20 _0. ...; _263 - 271 0- - 0 - - -_.0__ _ .__ 0 11 W _ Tailoredfoam_iniect 0.000 _ne._ _ 0.00_ 0.00 ._ _ 42_ 42 0 0_._. 0_ _ 0 _ 0 _0 Tailored foam.inject 0.000 a 0.00 0.00 520 392 0 0 0 0 0 0 1 Dc2ovd 0.570 a 15.96 62.36 80 0 1277 4989 0 0 0 0 4A5-2ov. 0.470 a 0.00 0.00 0 0 0 0 0 0 0 0 - 4A5-2ov 0.470 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0:470 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ovd- 0.470 a 13.16 21.29 48 32 632 1022 0 0 0 6 11D0 - _._ 0.3.90 e_ 0.00__:--0.00 _ .-____0 0 0 _ -0--. 0 0_. 0_ __ 0 W Tailored foam inject 0.000 se 0.00 0.00 _ 0 0 _0 0 0 0 0 0 Tailored foam inject '`0.600 -s 0.00 6.00 480 442 0 0 150 127 0 0 4A&2ov, 0.470 s 13.16 13.55 15 15 191 196 0 0 0 0 4A5-2ov 0.470 s 13.16 13.55 23 23 307 316 23 23 307 316 - - 4A5-2ov:_--- - -- 0.470--s _ -0.00____0.00 - 0 --� - 0 - 0 .'0_ - 0 __0 ------0 Tailored foam inject 0.000 w 0.00 0.00 550 323 0 0 200 165 0 0 1Dc2ov 0.570 w 15.96 59.33 35 3 559 2077 35 3 559 2077 1 Dc2ov 0.570 w 0.00 0.00 0 0 0 0 0 0 0 0 1Dc2ov 0.570 w 0.00 0.00 0 0 0 0 0 0 0 0 1 Dc2ovd 0.570 w 15.96 25.55 192 168 3064 4906 0 0 0 0 4A&2ov 0.470 w 0.00 0.00 0 0 0 0 0 0 0 0 4A&2ov 0,470 w_ 0.00 0.00 0 0 0 0 0 0 0 0 RR 12C-0sw .0.091 -- 0.00 0.00 - '0 0 --- 0 0 0 0 0 0 0.390 __n_ 0.00__._0.00 0_ _r-- 0 _ _0 _ - _0 _---- _o--- .- 0"___ _-.__0.___.- _0. R 12E-0sw 0.068 - 0.00 0.00 0 0 0 0 0 0 0 0 ---.D_ 11 D0 - ----0.390, n- 0.00_.._. 0.00 - 0 - 0 0 -0 -0- 0 0 - - 0 16X19 Omd__ .___ ___ -_0.408 ._r 1.59._ ..-_ .49 _ __.2050 _- _2050 __3250 _- 3046 _ 272___ _ 272 ___431 _ 404 F._ 19C-1,9cscr) _ _ 0.049 .- ._ 0.00 0.00 _ 0 _0 0. 0 0 0-_ 0 _-. 0 F 22Actpl-- Q.989_ - _ _ _0.00 _-0.00 - _0 - 0 '____0_' 0- _0'___ 0 - 0- F 22A-tpl- -•._. 0.989 _- - _ 27.69__ 0.00 -5_3 14._. _.376 _ _. 0 20 _ 3 .- 73 _._ .- 0 6 c)AED excursion 6485 525 Envelope loss/gain 10163 23560 1370 3322 12 a) Infiltration 3214 922 566 163 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 13377 24482 1937 3485 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 10 8 14 Subtotal 13377 24482 1947 3493 15 Duct loads 45% 17% 5965 4147 45% 17% 868 592 Total room load 19342 28629 2815 4084 Air required(cfm) 1600 1600 233 228 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. +� wrightsoft� 2017-Aug-01 08: 1 Right-Suite®Universal 2017 17.0.14 RSU08101 Pagege 10 ACCk ..lcs\Documents\SIMMERMACHER RESIDENCE-LOT$3.rup Calc=MJ8 Front Door faces: W i wri htsoft° Ri h�-J®Worksheet Job: 9 AHU#2 Date: Jun 26,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax:772466-6796 Email:QUICKCALCS@,AOL.COM 1 Room name GUESTBATH WIC 2 Exposed wall 13.0 ft 13.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 13.0 x 6.0 ft 7.0 x 6.0 ft 5 Room area 78.0 ft2 42.0 ft2 Ty Construction U-value Or HTM Area (ft� Load Area (ftJ Load number (Btuh/ftz°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Tailored foam inject - 0.000 n .-0.00 - 0.00 . _ 0. . -_0 7-0 _---- _.-.0 0 0 0 0 4A5-2ov 0.470 _ n 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov. 0.470 n 13.16 13.55 0 0 0 0 0 0 0 0 4A5.2ov ._.-_ 0:470 _n_- --13.16-.- 13.55 __ 0 __ 0 0 _-0 0 0, _ -,_0 11 W„ _-" Tailored foam infect 0.000 ne__ _ 0.00.---- 0.00 0 0 _ 0 0 0_ 0 0 _ - 0 _- Tailored foam inject 0:000 a 0.00 0.00 0 0 0 0 60 60 0 0 1 D-c2ovd 0.570 a 15.96 62.36 0 0 0 0 0 0 0 0 4A5-2ov 0:470 a 0.00: 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 e_ 0.00 0.00 0 0 0 0 0 0 0 0 4A5.2ov 0.470 a 0.00 0.00 0 0 -0 0 0 0 0 0 4A5-2ovd 0.470 a 13.16 21.29 0 0 0 0 0 0 0 0 _ 11 DO "-- - - 0.390 a 0.00--_0.00 - --0 - -0 0 °- ° °- - 0 _._ 0 W_ Tailored foam inject 0 Tailored foam inject 0.000 s 0.00 0.00 130 123 0 0 70 70 0 0 4A5-2ov 0.470 s 13.16 13.55 7 7 95 98 0 0 .0 0 4A5-2ov 0.470 s 13.16 13.55 0 0 0 0 0 0 0 0 �G 4A5.2ov_ ._ - - - 0.470 s --_0.W.__, 0.00- - 0 __ - -° 0 _-0 ... ° -- °- - -0 _. _0 Tailored foam inject 0.000 w 0.00 0.00 0 0 0 0 0 0 0 0 1 D-c2ov 0.570 w 15.96 59.33 0 0 0 0 0 0 0 0 1 D-c2ov 0.570 w 0.00 0.00 0 0 0 0 0 0 0 0 1D-c2ov 0.570 w 0.00 0.00 0 0 0 0 0 0 0 0 1 D-c2ovd 0.570 w 15.96 25.55 0 0 0 0 0 0 0 0 4A5-2ov 0.470 w 0.00 0.00 0 0 0 0 0 0 0 0 4A5 2ov.,-_ - 0,470 _w _ _0.00 0.00_ 0 _ 0 0 0__ 0 0 0__ _ 0 q 12C-0sw 0.091 0.00 0.00 0 0 0 0 0 0 0 0 �-p 11D0. " =-- 0:390 n - 0 _ _.00._..-0.00_- - -° ----0 0 . R 12E-0sw 0.068 - 0.00 0.00 0 0 0 0 0 0 0 0 --D--11D0 _ - _ 0.390 n _0.00_ -_ 0.000 _C_ 0 _- 16X19-0md- ._. .___ _ . ._0.408 _ -1 59 __ _1.49 78....- - 76 _ - _- 124 116 _._. 42 _. _ 42_.._ _67_ - _..62 ,F_. .- 19C-19cscq,. -0.049 - -- 0.00 0.00 - 0 0 0 - 0 0 0 0- 0 22A-tpl- .0.966 _ - ____0.00 0.00 _-.__ .0. 0 -_ _ 0 0 0 0 0_ - 0- F_ 22A-tpl__ -0.-989 _- _ 27.69-_ .0.00 0 0 0 0 - 0 _ 0 - 0 0 6 c)AED excursion -39 -17 Envelope loss/gain 219 175 67 45 12 a) Infiltration 205 59 205 59 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 424 234 271 104 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 424 234 271 104 15 Duct loads 45% 17% 189 40 45% 17% 121 18 Total room load 613 274 1 1 392 122 Air required(cfm) 51 15 32 7 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Q:- � wrightsoft- 2017-Aug-01 08:52:41 A Right-SuReO Universal 2017 17.0.14 RSU08101 Page 11 ...IcslDocuments%SIMMERMACHER RESIDENCE-LOT$3.rup Calc=MJ8 Front Doorfaces: W wri htsoft9 Ri PM Worksheet Job: 9 AHU#2 Date: Jun 26,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE, FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@,AOL.COM 1 Room name GUEST SUITE LAUNDRY 2 Exposed wall 21.2 ft 0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heaticool 4 Room dimensions 1.0 x 175.5 ft 7.0 x 15.0 ft 5 Room area 175.5 ft2 105.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Tailored foam inject 0000 n 0.00 0.00 50 50 0 0 - 0 0 0 0 4A5-2ov 0.470 n 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 n 13.16 13.55 0 0 0 0 0 0 0 0 4A572ov_ _.. __ _ 0.470 .n ---13.16_ 13.55 __ _. 0 _ 0 0 0 0 0_ _ _. 0_ 0 11 _W.. - Tailored foam,iniect_- 0..000 ne .,_ 0.00 . . 0.00 42_ _ 42 _ 0 0 0 _0 __ 0 ._ -_.. 0 Tailored foam inject• 6.000 a 0.00 0.00 120 80 0 0 0 0 0 0 1Dc2ovd 0.570 a 15.96 62.36 40 0 638 2494 0 0 0 0 4A5-2ov, 0.470 a 0.00 0.00 .0 0 0 0 0 0 0 0 4A5-2ov 0.470 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 a 0.00 " 0.00 0 0 0 0 0 0 0 0 4A5-2ovd 0.470 a 13.16 21.29 0 0 0 0 0 0 0 0 11D0 - - 0:390 _ e 0.00 .. 0.00 ° ° ° - ° - - ° 0 0.. _ . 0 W . Tailored foam inject _ 0.000 se 0.0.0 0.00 0 _0 __0 0 0 0 0 --.0 Tailored foam inject 0.000 s o.00 o.00 .0 0 0 0 -0 0 0 0 4A5-2ov 0.470 s 13.16 13.55 0 0 0 0 0 0 0 0 4A5-2ov 0.470 s 13.16 13.55 .0 0 0 0 0 0 0 0 AA5-2ov...-- - --•-0.470 s. 0.00_.._._ 0.00 -0. -0._ .. 0 0 .....- .. 0 __. .. .0__ 0-- 0 Tailored foam inject 0.000 w 0.00 0.00 0 0 0 0 0 0 0 0 1 Dc2ov 0.570 w 15.96 59.33 0 0 0 0 0 0 0 0 1Dc2ov 0.570 w 0.00 0.00 0 0 0 0 0 0 0 0 1Dc2ov 0.570 w 0.00 0.00 0 0 0 0 0 0 0 0 1 D-c2ovd 0.570 w 15.96 25.55 0 0 0 0 0 0 0 0 4A5-2ov 0.470 w 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov__ __-_ _ _ 0.470 w 0.00 _ 0.00 _ 0 0 _ _0 _ __ 0 0 0 _ 0__ _0 R 0 0 0 0 0 0 0 12C-Osw 0.091 - 0.00 0.00 0 �-D 11DQ - - -__O.390-n - 0.00-.__O.00 _.. -=0 -0 - --- 0 .__ 0 0 - 0 ° 0 P 12E-Osw 0.068 - 0.00 0.00 0 0 0 0 0 0 0 0 1--D _11 DO__ _ 0.390 _n-_ 0.00___ 0.00 0_ 0 _ _0 0- _-..- _0 __-_ _ 0 _ 0 0 1.59 ___1.49 - - 176 176 278 _ ._ 281. _. .105 105._-_ _-166 . - 156 19C-19cscp _ _ 0.049 -- ----0.00 _ -0.00 - -- - 0. - 0 ° _ .... .0- .. ° -__ _ 0 -0 F: . : 22A-tpl_ 0.989- - 0.989 0._989 -- -_ 27.69 , 6 c)AED excursion -45 -22 Envelope loss/gain 917 2710 166 134 12 a) Infiltration 334 96 0 0 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1251 2806 166 134 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1251 2806 166 134 15 Duct loads 45% 17% 558 475 45% 17% 74 23 Total room load 1809 3281 241 157 Air required(cfm) 150 183 20 9 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed wrightsoft- Right-Suite®Universal 2017 17.0.14 RSU08101 2017-Aug-01 08:52:41 Pa12 ''��` ...IcslDocuments\SIMMERMACHER RESIDENCE-LOT$3.rup Calc=MJ8 Front Door faces: W ge wri htsoft' Ri h ®Worksheet Job: 9 AHt-JU#2 Date: Jun 26,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name AHU 2 CLST SITTING 2 Exposed wall 0 ft 16.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 5.0 x 5.0 ft 1.0 x 191.0 ft 5 Room area 25.0 ft2 191.0 ftz Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft;°F) (Btuwft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V Tailored foam inject 0.000 n 0.00 0.00 0 0 0 0 0 0 0 0 4A&2ov 0.470 n 0.00 0.00 0. 0 0 0 0 0 0 0 4A5-2ov 0.470 n 13.16 13.55 0 0 0 0 0 0 0 0 _,-- 4A5-2ov__. ...... __ --0.470- n _13.16__13.55_ 0 - - _0 -----_0 __0 0 0 ._-- 0_ 11 W-._ Tailored-foam inject .. . 0.000 ne 0.00_- 0.00 _ 0 0 0. - 0 _.. - 0 .0 0 __-, _ _0 Tailored foam inject 0.000 a 0.00 0.00 0 0 0 0 0 0 0 0 1 D-c2ovd 0.570 a 15.96 62.36 0 0 0 0 0 .0 0 0 4A5-2ov 0.470 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov, 0.470 a 0.00 0:00 0 0 0 0 0 0 0 0 4A5-2ovd' 0.470 a 13.16 21.29 0 0 0 0 0 0 0 0 11 DO"_ __._.--. 0.390 e __ 0.00__ 0.00 _ _ _0.- - _ 0 0- 0--._.-_ 0 W Tailored foam inject__ 0.000 se -0.00 0.00 6 0 0 6 0 0 0 0 Tailored foam inject 0.000 s 0.00 0.00 - 0 0 0 0 0 0 0 0 4A5-2ov 0.470 s 13.16 .13.55 0 0 0 0 0 0 0 0 4A5-2ov 0.470 s 13.16 13.55 0 0 0 0 0 0 0 0 0:470 .s -__0,00.-._..0.00 __ _..._0. . _ _0 ..-._. _0 0--- 0_-- _ Tailored foam inject 0.000 w 0.00 0.00 0 0 0 0 160 64 0 0 1 D-c2ov 0.570 w 15.96 59.33 0 0 0 0 0 0 0 0 1 D-c2ov 0.570 w 0.00 0.00 0 0 0 0 0 0 0 0 1 D-c2ov 0.570 w 0.00 0.00 0 0 0 0 0 0 0 0 1 D-c2ovd 0.570 w 15.96 25.55 0 0 0 0 96 84 1532 2453 4A5-2ov 0.470 w 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov _ 0.470 --w - -0.00.- _0.00 0 0 _ _ 0 0 _ _ 0 0 _ 0 0 Fj uc-osw, 0.091 - 0.00 0.00 0 0 0 0 0 0 0 0 L-=n 11 DO'. -- .._ _.__0.390- n - 0.00" _0.00_. - -0 0 0 PI - 12E-0sw 0.068 - 0.00 0.00 0 0 0 0 0 0 0 0 L-D 11D0 _ _-- _ _0.390 n-_ _-, 0.00_ 0.00 , 0 0 0 0 _" 0__ 0 - 0 _ 0 C ..-_ 16X1970md_-_ --- - _..0.408 - 1.59 _ 1.49 _.-.___25__ 25-- -- .40 - _---37-_- ._191 _ 191 __. - 303 284 F- ._ 19C-19cscp 0.049 - Q-00 - 0.00 _ 0 0 0. - 0 - 0 - 0 _0_ 0 -- F . . 22A-tpl__..:_. _ _0:989.-_- 0 F _ _ 22A_tpl.--__--- - _ 0:989 - 27.69 0.00 _ _0".- 0 0 0 6 c)AED excursion -5 3371 Envelope loss/gain 40 32 1835 6108 12 a) Infiltration 0 0 252 72 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 40 32 2087 6180 Less external load 0 0 0 0 Less transfer 0 0. 0 0 Redistribution -40 -32 20 16 14 Subtotal 0 0 2107 6196 15 Duct loads 45% 17% 0 0 45% 170/o 939 1049 Total room load 0 0 3046 7246 Air required(cfm) 0 0 _F 1 252 405 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wwrightsof - 2017-Aug-01 08:62:41 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 13 �� ...lcs\Documents\SIMMERMACHER RESIDENCE-LOT$3.rup Calc=MJB Front Door faces: W wry9 Vilh -J@ htsoft° Worksheet Job: U#2 Date: Jun 26,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS(@,10L.COM 1 Room name LOFT MASTER SUITE 2 Exposed wall 17.0 ft 36.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 1.0 x 369.0 ft 1.0 x 383.0 ft 5 Room area 369.0 ft2 383.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Tailored foam inject 0.000 n 0.00 0.00 0 0 0 0 170 150 0 0 �l; CCCI 4A5-2ov 0,470 n 0.00 0.00 0 0 0 . 0 0 0 0 0 4A5-2ov 0.470 n 13.16 13.55 0 0 0 0 0 0 0 0 4A5-2ov 0.470 n 13.16 13.55 .0- 0 0 0 0 --.0 _ 0_ __ 20 _ _ . 0 263 _271 11 W-. Tailored foam inject_-_ _ 0.000 ,ne 0.00 0.00 0- _ 0 0 _ 0 _ _ -0 ._ Tailored foam inject 0.000 , e 0.00 0.00 120 72 0 0 0 0 0 0 1 D-c2ovd -.0.570 a 15.96 62.36 0 0 0 0 0 0 0 0 4A5-2ov 0.470 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 a 0.00. 0.00 0 0 0 0 0 0 0 0 4A5.2ov 0.470 a 0,00 0.00 '0 0 0 0 0 0 0 0 4A5.2ovd, 0.470 a 13.16 21.29 48 32 632 1022 0 0 0 0 11D0- - - 0.390 -e- -- 0.00_. _.0.00 ---.0 -0- - - 0 . W _ Tailored foam inject_ 0.000 se 0.00 0.00 0 0 0 0 0 0 0 - 0 Tailored foam inject 0.000 s 0.00 0.00 50 43 0 0 0 0 0 0 4A5-2ov 0.470 s 13.16 13.55 7 7 95 98 0 0 0 .0 4A5-2ov,' 0.470 s 13.16 13.55 0 0 0 0 0 0 0 0 4A5 2ov ---- . _ ._0.4.70--s ---- 0.00_.__0.00.- - _- . 0, ---- 0. _ __0 -_ 0 0_ -_ 0 0-. 0 Tailored foam inject 0.000 w 0.00 0.00 0 0 0 0 190 94 0 0 1 D-c2ov 0.570 w 15.96 59.33 0 0 0 0 0 0 0 0 1 D-c2ov 0.570 w 0.00 0.00 0 0 0 0 0 0 0 0 1Dc2ov 0.570 w 0.00 0.00 0 0 0 0 0 0 0 0 1 D-c2ovd 0.570 w 15.96 25.55 0 0 0 0 96 84 1532 2453 4A5-2ov 0.470 w 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov __ 0.470_w 0.00 - „__0.00 _ _ _0 _ 0 .______0 0 0 0 _ _0 0 R . 12t-0 0.091 0.00 0.00 0 .0 0 0 0 0 0 0 11D0 ._ - -0.390_n__ __0.00 �__ 0.00 -- --0 ----. 0 - - ---0 -- 0 ----- __0 _._.0.-- -0._ � 0 PI 12E-0sw 0.068 - 0.00 0.00 0 0 0 0 0 0 0 0 L D 11D0 0.390 n - 0.-00 -_ 0.00 - 0 - - -- 0 - 0 - 0 - 0 - - -0- _0 -_0 16X19 _1 0md -__ _0.408__- - _-. .59__: 1.49 369 368 , __585 548_ 383 _ _.- 383-__- . 607_. ..__569 F_ 19C-19cscr) _ _ 0.049 - 0.00 0.00 _ _ -0 0 0 0 0 0 0 0 F-= 22A-tpl '- - - -_ag960 _ -.0.00 0.00 -0 _ 6 . . o _ 0 0 F. . M tpl-. .. - 0.969_- - - 27,69 0.00 0 _ 0 0_ . 0 - '0 0- - -.0 6 c)AED excursion -248 3224 Envelope loss/gain 1312 1421 2403 6517 12 a) Infiltration 268 77 566 163 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1580 1498 2969 6679 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 10 8 0 0 14 Subtotal 1590 1506 2969 6679 15 Duct loads 45% 17% 709 255 45% 17% 1324 1131 Total room load 2298 1761 4293 7811 Air required(cfm) 190 98 1355 437 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed �A wrightsoft' Right-SuRe® 2017-Aug-0108:52:41 Universal 2017 17.0.14 RSU08101 Page 14 ..Ics\Documents\SIMMERMACHER RESIDENCE-LOT$3.rup Calc=MJ8 Front Doorfaces: W • (� Job: wri htsoft Ri h�-M Worksheet 9 AHU#2 Date: Jun 26,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name W.I.C. WIC 2 2 Exposed wall 8.0 ft 0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 8.0 x 7.0 ft 1.0 x 45.0 ft 5 Room area 56.0 ft2 45.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2--°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Tailored foam inject 0.000 n 0.00 0.00 80 80 0 0 _ 0 0 0 0 4A5-2ov 0.470 n 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 n 13.16 13.55 0 0 0 0 0 0 0 0 4A5 2ov --- 0.470 _n. _13.16 .... 13.55 - _.0-- - 0 _ .._- 0 0 0 0 0 0 11 W____ Tailored foam inject_ . _ 0 000_ne _ _ 0.00 _ _0.00 _ 0 _0 __- _ 0 _ 0. _ ____0 _- _ _ 0 0 __ 0 Tailored foam inject 0.000 a 0.00 0.00 0 0 0 0 0 0 0 0 -1 D-c2ovd 0.570 'e 15.96 62.36 0 0 0 0 0 0 0 0 4A5-2ov 0.470 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ovd 0.470 a 13.16 21.29 0 0 0 0 0 0 0 0 11DO- --- 0.390 -e -- -0.00- -_0.00 --- 0 -- __-0- _ _0 _ __0 _-. -- 0 -- 0_ W Tailored foam inject 0.000 se 0.00 0.00 0 0 0 0 0 0 0 0 Tailored foam inject --0.000 s- - 0.00 0.00 - - 0 0 _ .0 - 0 - -- 0 -- 0 - 0 - -_ -0 4A5-2ov 0.470 s 13.16 13.55 0 0 0 0 0 0 0 0 4A5-2ov 0.470 s 13.16 13.55 0 0 0 0 0 0 0 0 4A52ov__ _ 0.470 s__. .0.00 0.00 ... ......0...__ 0 _ -..0- - -- -_0 -0 -- -. 0-•-- -.0---..__ 0 Tailored foam inject 0.000 w 0.00 0.006 0 0 0 0 0 0 0 1 D-c2ov 0.570 w 15.96 59.33 0 0 0 0 0 0 0 0 1D-c2ov 0.570 w 0.00 0.00 0 0 0 0 0 0 0 0 1 D-c2ov 0.570 w 0.00 0.00 0 0 0 0 0 0 0 0 1 D-c2ovd 0.570 w 15.96 25.55 0 0 0 0 0 0 0 0 4A5.2ov 0.470 w 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov____ ____ _ _0.470 w __ 0,00 _ _0.00 0 0 _ _0 _ _ 0 .__ _ 0_ 0 _ 0 0 12C-0sw 0.091 - o.00 0.00 0 - 0 0 0 0 0 0 0 11D0- -- -- - --0:390 n - 0.00- _0.00 - 0. - . . ,0_ -0 0.- -- 0 - 0 - 0 0 PI - 12E-Osw 0.068 - 0.00 0.00 0 0 0 0 0 0 0 0 L -U 11D0 0.390 n_ 0.00 0.00 0 0 0 0 0 0 0 0 C____ .16X19-0md_--._ _-__ ._ 0.408._- - _ _ 1.59_ __1.49_ _56_ _ .56_. __89 83 --- 45 _-_ _45 _ 71 _ _ __67 .F ...__ 19C-19cscp .00,_,. ... _ 0.049 _-_ 0.00 ___0 01 0 _ .- .0 _.0-. --. -0 -0 --- - -0 .- - -0- .FZA-tp( -- -_ _-- 0.989 - - 0.00 _. 0.00.- 0 _0 0 0 0 - 0 0 F. -_ 22A-tol_ - -- 0.989 27.69 0.00 - 0 0 0 - 0- 0 - 0 0 6 c)AED excursion -17 _9 Envelope loss/gain 89 66 71 57 12 a) Infiltration 126 36 0 0 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 215 102 71 57 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 215 102 71 57 15 Duct loads 45% 17% 96 17 45% 17% 32 10 Total room load 310 1201 103 67 Air required(cfm) 26 7 9 4 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .4C= 4- wrightscWV 2017-Aug-01 08:52:41 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 15 ...Ics\Documents\SIMMERMACHER RESIDENCE-LOT$3.rup Calc=MJ8 Front Door faces: W wri htsoft° h -Ri M)Worksheet Job: g AHU#2 Date: Jun 26,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772466-6796 Email:QUICKCALCS@,10L.COM 1 Room name MASTER BATH TOILET 2 Exposed wall 30.9 ft 13.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 1.0 x 270.5 ft 1.0 x 37.5 ft 5 Room area 270.5 ft2 37.5 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (BtulV t2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Tailored foam inject 0.000 n �0.0d 0.00 140 121 0 0 - 0 0 0 0 4A5-2ov 0.470 n 0.00 0.00 0 0 0 0 0 0 0 0 G 4A5-2ov 0.470 n 13.16 13.55 19. 0 246 253 0 0 0 0 AA5-2ov--- - -- - _0.470 _n-- .13.16-- 13.55 - - ---. 0- -0 ----._0.- --0 . .._ 0 _ _. 0 - -0 - 0 11 W Tailored foam infect _. _ _0.000 ne _ 0.60_,_ 0.00 0 6 --_0. _ 0 __,-__0 _ _ 0 0 0 Tailored foam inject 0.000 a 0.00 0.00 160 12.0 0 0 60 60 0 0 ID-c2ovd- 0.570 a 15.96 62.36 40 0 638 2494 0 0 0 0 4A5-20v 0.470 a 0.00 0.00 0 0 0 D 0 0 0 0 4A5-2ov 0.470 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ovd 0.470 a 13.16 21.29 0 0 0 0 0 0 0 0 .- - 11D0----- - -.- 0.390 e__•_ 0.00 - 0.00 0,----- -0 - --- ..0 _.- - 0--- -0,--Tailored foam inject 0.000 se 0.00 0.00 0 0 0 _ 0 0 0 0 0 Tailored foam inject _ 0.000 s 0.00 0.00 10 10 0 0 70 70 0 0 4A5-2ov-- 0.470 s 13.16 13.55 0 0 0 0 0 0 0 0 4A5-2ov. 0.470 s 13.16 13.55 0 0 0 0 0 0 0 0 - --- _ 4A5-20v._.- 0.470 _s 0.00_. _ 0.00 IQ_ . 0 _ 0. . 0 .- __ 0 0 Tailored foam inject 0.000 w 0.00 0.00 0 0 0 0 0 0 0 0 1Dc2ov 0.570 w 15.96 59.33 0 0 0 0 0 0 0 0 1 D-c2ov 0.570 w 0.00 0.00 0 0 0 0 0 0 0 0 1 Dc2ov 0.570 w 0.00 0.00 0 0 0 0 0 0 0 0 1 D-c2ovd 0.570 w 15.96 25.55 0 0 0 0 0 0 0 0 4A5-2ov 0.470 w 0.00 0.00 0 0 0 0 0 0 0 0 - 4A5-2ov- 0.470 w_ .0.00- _0.00 -0- ---0, -0- - 0 -0 0 - 0 - -0 I: 12C-osw; 0.091 - 0.00 0.00 0 0 0 0 0 0 0 0 _D 11D0 _..w:_ 0.390 n_ -0.00--'-_ 0.00 -- _ _ =_0: . 0 0 00--_-- -0-- _ - -0 P 12E-Osw 0.068 - 0.00 0.00 0 0 0 0 0 0 0 0 L-D _11 DO_ 0.390 _n_ _ 0.00 0.00 _ _ 0 0 0 0 0 _ _ 0 0 0 .- C.- 1.6X19-0md_- _ _ 0.408 _- 1.59,_ 1.49_ __. _271_ 271 429. _ 402 _ . 38 _ 38 _ 59 _-_�_ 56- F 1C-19csCp ___ _ 0.049 - 0:00 0.00- -F- - 22A7tPl - - - 0.989 -0.00 __T 0.00 0 . 0 - Q - - 0 _ 0 . ---_. ------0 - 0 F 22A-tpl 0.989 - 27.69 0.00 2 0 5 0 31 11 298 0 6 c)AED excursion -217 -16 Envelope loss/gain 1318 2933 357 39 12 a) Infiltration 488 140 205 59 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1805 3072 562 98 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1805 3072 562 98 15 Duct loads 45% 17% 805 520 45% 17% 250 17 Total room load 2611 3593 812 115 Air required(cfm) 216 201 67 6 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft� 2017-Aug-01 08:52:41 14- Right-Suite®Universal 2017 17.0.14 RSU08101 Page 16 ..Ics\Documents\SIMMERMACHER RESIDENCE-LOT$3.rup Calc=MJ8 Front Doorfaces: W Duc stem Summary Job: wrightsoft® t System � date: Jun 26,2017 AHU#1 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM Project • • For: SIMMERMACHER LOT#4 7912 S. OCEAN DRIVE, JENSEN BEACH, FL 34957 Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.250/0.250 in H2O 0.250/0.250 in H2O Lowest friction rate 0.193 in/100ft 0.193 in/100ft Actual air flow 1950 cfm 1950 cfm Total effective length (TEL) 259 ft SupplyBranch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Mat[ Ln (ft) Ln (ft) Trunk BATH h 358 27 8 0.215 4.0 Ox0 VIFx 48.1 185.0 st9 CABANA h 1569 120 79 0.196 6.0 Ox0 VIFx 60.2 195.0 st7 CLST. h 25 2 1 0.227 4.0 Ox 0 VIFx 45.1 175.0 st9 DINING h 2570 197 133 0.271 7.0 Ox0 VIFx 19.5 165.0 st9 EXERCISE h 1216 93 51 0.197 6.0 Ox0 VIFx 54.1 200.0 st7 EXERCISE-A h 1216 93 51 0.193 6.0 Ox0 VIFx 53.8 205.0 st7 FOYER h 1511 116 44 0.252 6.0 Ox0 VIFx 28.4 170.0 st9 KITCHEN c 2164 84 112 0.247 7.0 Ox0 VIFx 22.5 180.0 st8 KITCHEN-A c 2164 84 112 0.423 7.0 Ox0 VIFx 23.2 95.0 st8 LIVING ROOM c 6401 155 331 0.216 9.0 Ox0 VIFx 41.5 190.0 st8 LIVING ROOM-A c 6401 155 331 0.231 9.0 Ox 0 VIFx 31.0 185.0 st8 LOWER FOYER h 2082 159 49 0.220 6.0 Ox 0 VIFx 42.7 185.0 st7 MAIDS QUARTERS h 2588 198 130 0.224 7.0 Ox 0 VIFx 43.2 180.0 st9 MEDIA ROOM c 4775 150 247 0.201 9.0 Ox0 VIFx 53.4 195.0 st8 MEDIA ROOM-B c 4775 150 247 0.196 9.0 Ox0 VIFx 54.5 200.0 st8 POWDER h 23 4 1 0 0 Ox 0 VIFx 0 0 STAIRS h 78 25 4 0 0 Ox0 VIFx 0 0 STOR. h 1804 138 20 0.201 4.0 Ox0 VIFx 59.2 190.0 1 st7 wri htsofta 2017-Aug-0108:52:45 �," 9 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 1 Arm ...lcs\Documents\SIMMERMACHER RESIDENCE-LOT$3.rup Calc=MJ8 Front Door faces: W Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st1 Peak AVF 603 250 0.193 564 14.0 0 x 0 VinlFlx st7 Peak AVF 603 250 0.193 564 14.0 0 x 0 VinlFlx st6 st6 Peak AVF 603 250 0.193 564 14.0 0 x 0 VinlFlx st1 st8 Peak AVF 778 1379 0.196 573 21.0 0 x 0 VinlFlx st2 st2 Peak AVF 778 1379 0.196 573 21.0 0 x 0 VinlFlx st9 Peak AVF 539 316 0.215 585 13.0 0 x 0 VinlFlx st3 st3 Peak AVF 539 316 0.215 585 13.0 0 x 0 VinlFlx TableReturn Branch Detail Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening (in) Matl Trunk rb3 Ox 0 1950 1950 0 0 0 0 Ox 0 VIFx wri htsoft" 2017-Aug-0108:52:45 9 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 2 ACCA ...Ics\Documents\SIMMERMACHER RESIDENCE-LOT$3.rup Calc=MJ8 Front Door faces: W . ,�. 9 ® Duct System Summary Job: wri htsoft y Date: Jun 26,2017 AHU #2 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772466-6796 Email:QUICKCALCS@AOL.COM Project • • For: SIMMERMACHER LOT#4 7912 S. OCEAN DRIVE, JENSEN BEACH, FL34957 Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.250/0.250 in H2O 0.250/0.250 in H2O Lowest friction rate 0.200 in/100ft 0.200 in/100ft Actual air flow 1600 cfm 1600 cfm Total effective length (TEL) 249 ft SupplyBranch Detail Table Design Htg CIg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Mat] Ln (ft) Ln (ft) Trunk GUEST SUITE c 3281 150 183 0.310 7.0 Ox 0 VIFx 21.4 140.0 st12 GUESTBATH h 613 51 15 0.221 4.0 Ox0 VIFx 26.2 200.0 st12 LAUNDRY h 241 20 9 0.287 4.0 Ox 0 VIFx 14.4 160.0 st12 LOFT h 2298 190 98 0.471 7.0 Ox0 VIFx 16.1 90.0 st4 MASTER BATH h 2611 216 201 0.205 7.0 OxO VIFx 44.3 200.0 st11 MASTER SUITE c 3905 178 218 0.253 9.0 Ox0 VIFx 37.3 160.0 st11 MASTER SUITE-B c 3905 178 218 0.316 9.0 Ox 0 VIFx 28.2 130.0 st10 OFFICE h 1407 116 114 0.504 7.0 Ox0 VIFx 9.2 90.0 st5 OFFICE-A h 1407 116 114 0.375 7.0 Ox 0 VIFx 23.2 110.0 st5 SITTING c 7246 252 405 0.401 9.0 Ox0 VIFx 14.6 110.0 st10 TOILET h 812 67 6 0.200 4.0 Ox 0 VIFx 49.4 200.0 st11 W.I.C. h 120 26 7 0 0 Ox 0 VIFx 0 0 WIC h 392 32 7 0.235 4.0 Ox 0 VIFx 32.6 180.0 st12 WIC 2 h 103 9 4 0.231 4.0 Ox 0 VIFx 36.0 180.0 st11 SupplyDetail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st5 Peak AVF 485 442 0.221 527 13.0 0 x 0 VinlFlx st11 Peak AVF 469 429 0.200 597 12.0 0 x 0 VinlFlx st10 st10 Peak AVF 899 1052 0.200 596 18.0 0 x 0 VinlFlx st4 st4 Peak AVF 1089 1151 0.200 584 19.0 0 x 0 VinlFlx st12 Peak AVF 253 214 0.221 572 9.0 0 x 0 VinlFlx st5 wri htsoft® 2017-Aug-0108:52:45 9 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 3 ...Ics\Documents\SIMMERMACHER RESIDENCE-LOT$3.rup Caic=MJ8 Front Door faces: W Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening(in) Mat[ Trunk rb2 Ox0 1600 1600 0 0 0 0 Ox 0 VIFx c wri htsoft® 2017-Aug-0108:52:45 9 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 4 ACCA ...Ics\Documents\SIMMERMACHER RESIDENCE-LOT$3.rup Calc=MJ8 Front Door faces: W