Loading...
HomeMy WebLinkAboutProduct Approval - exterior Doors 7/28/2017 Florida Building Code Online BCIS Home Log In I User Registration I Hot Topics I Submit Surcharge I Stats&Facts I Publications I FBC Staff BCIS Site.Map I Links I Search dbpr a I k �,,�� Product Approval USE Public Use Product Approval Menu>Product or Application Search>Application List>Application Detail • FL# FL14429-115 Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Andersen Corporation Address/Phone/Email 100 Fourth Avenue North Bayport,MN 55003 (651)264-5308 alan.barstad@AndersenCorp.com Authorized Signature Alan Barstad alan.barstad@AndersenCorp.com Technical Representative Address/Phone/Email Quality Assurance Representative Alan Barstad Address/Phone/Email 100 Fourth Avenue North Bayport,MN 55003 (651)264-5308 abarstad@andersencorp.com Category Exterior Doors Subcategory Sliding Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer %{ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Hermes F.Norero,P.E. the Evaluation Report Florida License PE-73778 Quality Assurance Entity Window and Door Manufacturers Association Quality Assurance Contract Expiration Date 12/31/2018 Validated By Locke Bowden Validation Checklist-Hardcopy Received Certificate of Independence FL14429 R5 COI Andersen COI SS 2015-02-23.odf Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA 101/I.S.2/A440 2005 AAMA/WDMA/CSA 101/I.S.2/A440 • 1 Fy AAMA/WDMA/CSA 101/I.S.2/A440p };? ASTM E 1886 FLE M� ' ASTM E 1886 2005 ASTM E 1996 2012 ASTM E 1996 2002 TAS 201 1994 TAS 202 1994 http://miww.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDquiKNpeAsup/p2bZPP3jp/p2ba4esDUaDyzs4WTjjF1v84JHvgBCQp/*3dp/`3d 1/3 7/28/2017 Florida Building Code Online TAS 203 1994 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted . 04/24/2015 Date Validated 04/25/2015 Date Pending FBC Approval 04/28/2015 Date Approved 06/23/2015 Summary of Products FL# Model,Number or Name Description 114429.1 400 Series Frenchwood Gliding Door Limits of Use Installation Instructions Approved for use in HVHZ: No FL14429 R5 II AWD007 SS 2015-04-20.odf Approved for use outside HVHZ:Yes Verified By:Hermes F.Norero,P.E.Florida RE.#73778 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure.N/A Evaluation Reports I'I Other:Refer to pressure tables on drawing AWD007(Note: FL14429 PS AE PER3518 SS 2015-04-21.13df All pressures meet water infiltration requirements) Created by Independent Third Party:Yes 14429.2 A Series FWGD Gliding Doors Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL14429 R5 II AWD023 SS 2015-04-20.2df Approved for use outside HVHZ:Yes Verified By: Hermes F.Norero,P.E.Florida P.E.#73778 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Refer to pressure tables on drawing AWD023(Note: FL14429 R5 AE PER3519 SS 2015-04-21.Ddf All pressures meet'water infiltration requirements).Plastic Created by Independent Third Party:Yes Material Certification of laminated glazing interlayers are listed under current Miami-Dade NOAs. 14429.3 A Series FWGD DP Upgrade Gliding Doors Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL14429 R5 II AWD040 SS 2015-04-20.Ddf Approved for use outside HVHZ:Yes Verified By: Hermes F. Norero,P.E.Florida P.E.73778 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Refer to pressure tables on drawing AWD040(Note: FL14429 R5 AE PER3520 SS 2015-04-21.Ddf All pressures meet water infiltration requirements) Created by Independent Third Party:Yes 14429.4 Series 100 Gliding Patio Doors Limits of Use Installation Instructions Approved for use in HVHZ:No FL14429 R5 II AWD035 SS 2015-04-20.Ddf Approved for use outside HVHZ:Yes Verified By: Hermes F. Norero,P.E.Florida P.E.#73778 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+30/-30 Evaluation Reports Other:Refer to pressure tables on drawing AWD035(Note: FL14429 R5 AE PER3521 SS 2015-04-21.Ddf All pressures meet water infiltration requirements) Created by Independent Third Party:Yes Hack ;3ext Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.;Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emaft provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public To determine if you are a licensee under Chapter 455,F.S., please dick here. Product Approval Accepts: OR tL6ec(c http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDquiKNpeAsug/o2bZPP3j%2ba4esDUaDyzs4WTEFlv84JHvgBCQg/o3d`/o3d 2/3 7/28/2017 Florida Building Code Online BCIS Home I Log In l user Registration I Hot Topics I Submit Surcharge I Stats&Facts I Publications I FSC Staff 1! BCIS Site Map I Unks I Search 1 Florida rLL Product Approval USER:Public User _ ...r:r.�s';"ter•r--:. ' Product Approval Menu>Product or Application Search>Aoolication List>Application Detail FL# FL14285-R5 kF Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Andersen Corporation Address/Phone/Email 100 Fourth Avenue North Bayport,MN 55003 (651)264-5308 alan.barstad@AndersenCorp.com Authorized Signature Alan Barstad alan.barstad@AndersenCorp.com Technical Representative Address/Phone/Email Quality Assurance Representative Alan Barstad Address/Phone/Email 100 Fourth Avenue North Bayport,MN 55003 (6S1)264-5308 abarstad@andersencorp.com Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Hermes F.Norero,P.E. the Evaluation Report Florida License PE-73778 Quality Assurance Entity Window and Door Manufacturers Association-QA Quality Assurance Contract Expiration Date 12/31/2018 Validated By Locke Bowden �f; Validation Checklist-Hardcopy Received Certificate of Independence FL14285 R5 COI Andersen COI SS 2015-02-23.odf Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA 101/CSA 101/I.S.2/A440 2005 AAMA/WDMA 101/CSA 101/I.S.2/A440 2008 ASTM E 1886 2002 ASTM E 1886 2005 ASTM E 1996 �2 ASTM E 1996 2 TAS 201 J ^i99+I TAS 202 FLE 1994 TAS 203 1994 http://Www.hoddabuilding.org/pr/pr app_dti.aspx?param=wGEVXQwtDquDEJErtOSCeus%2b5Sk3lhC%2fgPjKV6whgXcdT04gSQClTw%3d%3d 1/3. 7/28/2017 ' Florida Building Code,Online Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/24/2015 Date Validated 04/25/2015 Date Pending FBC Approval 04/28/2015 Date Approved 06/23/2015 Summary of Products FL# Model,Number or Name Description 14285.1 400S FWI Standard 400 Series Frenchwood Inswing Doors.Single,Double,&Triple Configurations Limits of Use Installation Instructions Approved for use in HVHZ:No FL14285 R5 II AWD078 SS 2015-04-21.odf Approved for use outside HVHZ:Yes Verified By:Hermes F.Norero,P.E.Florida P.E.#73778 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+40/-40 Evaluation Reports Other:See drawing AWD078 for approved design pressures FL14285 R5 AE PER3510 SS 2015-04-21.odf per configuration.All pressures meet water infiltration Created by Independent Third Party:Yes requirements. 14285.2 400S FWO Standard Outswing Single and French Doors Limits of Use Installation Instructions Approved for use in HVHZ: No FL14285 R5 II AWD018 SS 2015-04-20.1)df Approved for use outside.HVHZ:Yes Verified By:Hermes F.Norero,P.E.Florida P.E.73778 Impact Resistant:No Created by Independent Third Party:Yes. Design Pressure:N/A Evaluation Reports Other:See drawing AWD018 for approved design pressures FL14285 R5 AE PER3511 SS 2015-04-21.Ddf per configuration.All pressures meet water infiltration Created by Independent Third Party:Yes requirements. 14285.3 A Series FWOD Outswing Single and French Doors Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL14285 R5 II AWD024 SS 2015-04-20.1)df Approved for use outside HVHZ:Yes Verified By: Hermes F.Norero,P.E.FL PE#73778 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See drawing AWD024 for approved design pressures FL14285 R5 AE PER3512 SS 2015-04-21.Ddf per configuration.All pressures meet water inflitration Created by Independent Third Party:Yes requirements.Plastic Material Certification of PVB interlayer is listed under current Miami-Dade NOA. 14285.4 A Series FWOD DP Upgrade Outswing Single and French Doors _ Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL14285 PS II AWD039 SS 2015-04-20.Ddf Approved for use outside HVHZ:Yes Verified By: Hermes F.Norero,P.E.Florida P.E.73778 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See drawing AWD039 for approved design pressures FL14285 RS AE PER3513 SS 2015-04-21.Ddf per configuration.All pressures meet water inflitration Created by Independent Third Party:Yes requirements. oacl; Mext. . Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to•supply a personal address,please provide the Department with an email address which can be made available to the public To determine if you are a licensee under Chapter 455,F.S., please dick here. http://www.floridabuilding.org/pr/pr app_dtl.aspx?pafam=wGEVXQwtDquDEJErtOSCeusg/`2b5Sk3lhCp/o2f9PjKV6whgXcdTO4gSQClTw%3d%3d 213 Andersen. UNIT MAX. UNIT MAX. WIDTH 561/2", WIDTH 311/2" SASH MAX. SASH MAX. SASH MAX. • WIDTH 3011/32" WIDTH 27 7/32" WIDTH 27 7/32" Dl.OMAX. WINDOWS-DOORS WIDTH 271/8" D.L.O.MAX. D.L.O.MAX. WIDTH 24" E WIDTH 24" 800 FOURTH D e 4 - FW(651)26/-5150 fk.(651)26N165 D 4 4 4 pG m C m UNIT SASH MAX. UNIT D.L.O.MAX. w i m MAX. HEIGHT MAX. "X"or"0" HEIGHT <o Ga. F "X"or"0" Fn. G 70 5/16" HEIGHT X.or"0" HEIGHT 5 5 5 5 717/8" Gv F H 671/16" 9", 2m a 717/8" 5 5 5 SASH MAX. w� m F¢m12 D.L.O.MAX. Fes• G HEIGHT V) HEIGHT 5 5 70 5/16" c 67 1/16" w a ¢Jm w a a per, `C--',M A B F A B -.4 4 Q 4 4 ELEVATION ELEVATION CX16 CW26 Z � z UNIT MAX. UNIT MAX. WIDTH 717/8 SASH MAX. SASH WIDTH 3515/16 D.L.O.MAX. WIDTH 22 31/32" WIDTH 34 MAX.AX. WIDTH 19 3/4" LU D.L.O MAX. a WIDTH 319/1611 E 4 D E D 4 4 4 T Z �0 2j�I UNIT UNIT D,L.O.MAX. �%% O MAX. F>. G SASH MAX. MAX. HEIGHT X,. 5 5 HEIGHT HEIGHT "X"or"0" "X"or"0" "X"or"0" HEIGHT ���� ��• •r•••••,;� 5213/16" G"" F or 511/4" 59 7/8" Ga. F 55 1/16" O ^�u 5 5 "0" D.L.O.MAX. 5 5 H Fa. G SASH MAX. 2 O HEIGHT 5 5 5 HEIGHT u 48" 58 5/16" aw w A B 'A 4 4 Do �N 4 4 ~ u1 2= uZ Q AO ELEVATION ELEVATION DwG# V CXW145 C35 A W DO19 SHEET: 2 0F 6 Andersen_ WINDOWS-DOORS SEE ANCHOR 100 FOURTH A-N NORTH SEE ANCHOR SEE ANCHOR SEE ANCHOR SCHEDULE BELOW BAYPORT,MN 5mog-1096 SCHEDULE BELOW SCHEDULE BELOW SCHEDULE BELOW Pit.(651)264J150 FO(651)264-r85 .1 F ga O m^I Zi6& LL o�w im „x„ T In C m SEE ANCHOR SEE ANCHOR o ci F�o SEE ANCHOR SCHEDULE BELOW SEE ANCHOR SCHEDULE BELOW w < m ui m SCHEDULE BELOW SCHEDULE BELOW a¢ �1 a !J In ANCHOR,LAYOUT scHeD ANC eE ow� SEE ANCHOR SCHEDULE BELOW m ANCHOR LAYOUT • Z O Z. MIDSPAN AT tj HEAD A SILL o ANCHOR SCHEDULE HEAD/SILL •"z" INSTALLATION EDGE JAMB O.C. CORNER QTY PER EMBEDMENT O.L. Z TYPE LOCATION SUBSTRATE ANCHOR TYPE DISTANCE DISTANCE DISTANCE (IN.) DISTANCE (IN.) DISTANCE (IN.) SEE ANCHOR I (IN.) SEE ANCHOR SCHEDULE BELOW #8WOOD ��� •''•1•••• SCHEDULE BELOW CLIP 2 WOOD ANCHOR 1.5 0.75, 20 20 6 = O'a h CLIP 1 WOOD #fOWOOD 1.5 0.75 15 20 6 ANCHOR tL f- CONCRETE/ 3/16°ITW ;• ANCHOR LAYOUT `LIP 1 1.25 z.5 zD 20 6 •• MASONRY TAPLON #8 SELF- CLIP 2 METAL STUD TAPPING 3THREADS N/A 20 20 6 y�•*PROF SCREW Ell I1 w' °D(VN m 7 J 01 Go C:* == U,Z DWG#: A W D019 SHEET: 3 OF 6 TAPCON CAULK BETWEEN 3/1I"ITW INSTALLATION Andersen. dersen. CONCRETE/MASONRY d 2X ANCHOR WOOD BUCK BY OTHERS 11/2"MIN. � CONCRETE/MASONRY BY OTHERS EMBEDMENT CAULK BETWEEN CONCRETE/MASONRY 2 1/2"MIN. BY OTHERS #INSTAL0 WOODLATION IONSCR A CONCRETE/MASONRY&IX EDGE DISTANCE w i x n o w s•D O O x 6 ' INSTALLATION ANCHOR 2X WOOD BUCK ONE(1)PER CLIP WOOD BUCK BY OTHERS 3/4"MIN. 100 FOURTH T;6W SE 0o3 NORTH' BY OTHERS 1X WOOD BUCK EDGE PA:(651)M-500 rx-(esg26a-as DISTANCE CAULK BETWEEN BY OTHERS 11/4"MIN. xm, FIN S 2X 3/4"MIN. WOOD BUCK '' r EDGE DISTANCE CAULK BETWEEN EMBEDMENT EXTERIOR FINISH _11 FIN 61X v� o WOOD BUCK f o Vj m m BY OTHERS EXTERIOR FINISH c p u re a ERIM BY OTHERS P SEALANT I 2 1/4"MAX. t� ¢ m< BY OTHERS PERIMETER 1 22 SHIM SPACE SEALANT 26 I/4"MAX. HS a m 5 16 18 BY OTHERS 16 3 SHIM SPACE < �` LU H c O.A.WINDOW O.A. 118 9 HEI1GHT 11A 7 WINDOW HEIGHT 18 �]m 1 9' EXTERIOR INTERIOR EXTERIOR 7 INTERIOR SEE Q DETAIL ZING SEE GLAZING DETAIL 2 m VERTICAL SECTION NOTE:WHEN USING INSTALLATION VERTICAL SECTION (� HEAD-2X WOOD FRAME CLIP,ITEM#27,USE OF THE HEAD-IX WOOD/CONCRETE/MASONRY Z INSTALLATION CUP NAILING FIN IS REQUIRED. INSTALLATION CUP Q H Z 0 W V) w EXTERIOR INTERIOR EXTERIOR INTERIOR } SEE GLAZING SEE GLAZING 18 DETAILI 18 12 DETAIL 12 O.A.HEHT WINDOW 11A O.A. 118 TWO(2)#8 WOOD SCREW Z 10 WIM��W 10 INSTALLATION ANCHORS PER �� LIP 7 1/4"MAX. HEIGHT 7 16 26 C1/4"MAX. 1 16 26 SHIM SPACE PERIMETER 1 SHIM SPACE `� `,t..•••' SEALANT O, PERIMETER SEALANT---- ;y.• a •• ,, BY OTHERS L: = BY OTHERS ,•,r',.:: .•:• + :';:"'.. �. •}� x..;. 11/4"MIN. EXTERIOR FINISH 1 1/2"MIN. F �� •%'y- ;,:'•.:•• EMBEDMENT BY OTHERS EMBEDMENT y'; L- 3/16"ITW TAPCON •,y.':; INSTALLATION ANCHOR �.a •, CAULK BETWEEN t�• () " 21/2"MIN.EDGE ' 3/4"MIN.ONE 1 PER CLIP FIN 6 2X WOOD BUCK EDGE DISTANCE DISTANCE 2X WOOD BUCK BY OTHER a T PRECAST SILL--"" CONCRETE/MASONRY BY OTHERS O° BY OTHERS CAULK BETWEEN <o Z _� = u Z 'VERTICAL SECTION CONCRETE/MASONRY a 2X . VERTICAL SECTION o WOOD BUCK BY OTHERS SILL-2X WOOD/CONCRETE/MASONRY DWG#: O 4 SILL-PRECAST CONCRETE A INSTALLATION CUP A W DO / INSTALLATION CUP SHEET: 4 OF 6 3 THREADS MIN. 1/4"MAX. A PENETRATION BEYOND SHIM SPACE 11/4"MIN. Al`dersen. METAL FRAME 3/16"ITW TAPCON EMBEDMENT 1/4"MAX. INSTALLATION ANCHOR 3/4"MIN. SHIM SPACE ONE(1)PER CLIP EDGE DISTANCE INTERIOR WIRDOWS•000RS . INTERIOR - 100 FOURTH AVE N NORTH 5 BAYPORT.MN 58003-IM6 INTERIOR 21/2"MIN. PH:(691)264.O1B0 Fx:(601)261 HBB 17 17 26 EDGE DISTANCE co 26 8 �• � M TWO(2)#8 SELF-TAPPING 4 8 SCREW INSTALLATION SEE GLAZING SEE GLAZING +. .;� ° ' ANCHORS PER CLIP CONCRETE/MASONRY BY OTHERS w m DETAIL DETAILI a m METAL STUD FRAMING CAULK BETWEEN <a a 0 u Fi CONCRETE/MASONRY&IX ° -+ Sc BY OTHERS •' WOOD BUCK BY OTHERS � T � SHEATHING m w P �1• 1X WOOD BUCK =°NI DD F. m BY OTHERS BY OTHERS V) o zLu CAULK BETWEEN CAULK BETWEEN w a m°I In FIN&SHEATHING SEE GLAZING FIN&IX WOOD BUCK + d OUT EXTERIOR FINISH 25 28 2 7 118 DETAIL1 11A 7 4B 7 11A IA 7 2 25 EXTERIOR FINISH m BY OTHERS BY OTHERS O.A. EXTERIOR EXTERIOR PERIMETER SEALANT PERIMETER SEALANT O.A. BY OTHERS WIDTOHW EXTERIOR I HW BY OTHERS T m HORIZONTAL SECTION HORIZONTAL SECTION G� HORIZONTAL SECTION Z 5 JAMB•METAL STUD FRAME 5 INTEGRAL MULLION POST 5 JAMB-1X WOOD/CONCRETE/MASONRY O Z INSTALLATION CUP INSTALLATION CUP 10.1 MM O.A.LAMINATED GLAZING CONSISTING OF. � I F 3,9 MM ANNEALED LL h 0.090'SENTRYGLAS INTERLAYER BY DUPONT p 3.9 MM ANNEALED EXTERIOR INTERIOR 16.9 MM O.A.I.G.CONSI5TING OF: 1/2"MIN•GLASS Z 2.2 MM ANNEALED IIB BITE 10.1 MM O.A.LAMINATED GLAZING CONSISTING OF: ��� M AIR SPACEF 3,9 M ANNEALED ���� p 2.7 MM ANNEALED 0,090"SENTRYGLAS INTERLAYER BY DUPONT ��� �Ci .••'t•••a 3. d 0.090"SENTRYGLAS 1NTERLAYER BY DUPONT 3.9 MM ANNEALED 2.7 MM ANNEALED p EXTERIOR INTERIOR ` GLAZING SILICONE GE 7700 OR DC 1350 m' I- / 1/2"MIN.GLASS GLAZING DETAIL 2 / 1/2"MIN.GLASS �iy`yd •'•.,, ,.• ,,����•. t1A BITE 11B BITEill EXTERIOR INTERIOR �� m N m �vl poi US tZ GLAZING SILICONE GE 7700 GLAZING SILICONE GE 7700 DWG OR DC 1350 OR DC 1350 GLAZING DETAIL 1 GLAZING DETAIL 3 AWD019 SHEET: 5 OF 6 O FRAME HEAD/SILL O FRAME SIDE BILL OF MATERIALS Andersen,WOOD 2 WOOD NO PART NUMBER DESCRIPTIO MATERIAL MANU ACTURER 1 30835 FRAM AD SI L WOO A D RS N 2 30838 RA SI 00 ANDERSEN 4.125" c 4.125" 3 XT N5ION JAMB WOOD A DERSEN 4 '30839 MULLION P05T OOD ANDERSEN 48 MULLION POST CLADDING PVC ANDERSEN WINDOWS-00 0 R s 5 30056 MULLION POST CASING WOOD A D R5 N 100 FOURTH AVE N NORTH 1.344 1.094" 6 SASH RAIL/5TILE CLADDING PVC ANDERSEN BAYPORT,MN 55003.1096 7 30016 SASH RAIL 5TILWOOD A RS PH,(651)264-SM FX:(651)264-N85 8 30847 8 TRIM STOP JAMB WOO ANDERSEN 9 308 TRIM STOP AD OOD ANDERSEN O EXTENSION JAMB 5 MULLION POST CASING l0 30842-45 TRIM STOP SILL OOD ANDERSEN _ u $ WOOD O WOOD 11A 30184 GLAZING BEAD-I.&. p Z Z�c i1B GAZING BEAD-MONO.EAMI. PVC - z a 2.031" 12 30809 10 ROTO OPERATOR STEEL AMEROCK CORP. y w 1,969" 1- 13 30442 SNUGGER ALUMINUM chi X< ay 0.688" 14 #8 X 1/2" SNUGGER SCREW - a * a w�+ T- 15 30053 STATIONARY SASH CLIP GALV.STEEL w p a ¢m 16 HINGES STEEL AMEROCK CORP. o o o 0.680" 17 LOCK W KEEPERS ON SASH STEEL AMEROCK CORP. V) a-Icm w < m' 18 3021314 WEATHER STRIPPING ac 99, u s a 19 NOT USED (uwo m O MULLION POST 4B WOOD ST CLADDING 21 #8 X15/8" SASH REINFORCING BAR REINFORCING BARSCREWS ALUMINUM _ 22 BRAD NAILS 1-1/2"LONG I GALV.STEEL 4.813" 2.520" 23 30172 FOAM WEATHERSTRIPPING 24 25 30023 FRAME SIDE CLADDING PVC ANDERSEN 25A 30023 FRAME HEAD SILL CLADDING PVC ANDERSEN cc 2.000" 2.062" 26 INSTALLATION CLIP 304 5S N 27 INSTALLATION CLIP 304 55 1 28. 30442 EXTERIOR SNUGGER ALUMINUM Z NOTE: ALL WOOD TO BE 0 O. SASH RAIUSTILE CLAD. O7 SNASP OOD RAIUSTILE 8O WOOD WOOD STOP JAMB O TRIM STOP HEAD PONDEROSA PINE OR EQUAL H o TRIM STOP SILL H 1.900" 2.000° 2.000 10 WOOD Z.000" 2.000° _r w V) 1.452" 1.352" 0.891 %//�}m�rJ 0.89' 1" 1.406" L ll�l�fl!!G 11 GLAZING BEAD-I.G. 11B GLAZING BEAD-MONO.LAMI. 15 �ALvTS NARY SASH CLIP 20 SASTEEL MHIR`EMNF.BAR 25 FAR.SIDE CLADDING o „ 0.736" 3.0001, 2.713"� VC 0.728 Z 0;::: " 4 .721 1.593" 0 0.230" 2,530" 0.721 Lc OFRAME HEAD/SILL CLADDING O INSTALLATION CLIP O INSTALLATION CLIP O EXTERIOR SNUGGER 25A PVC 26 304 SS 27 304 5s 28 ALUMINUM %$ '•. ' ` 2,713" 3,000" 6.375" 0.024" 2.780" ® 01 ® ® ,9 .643" a m mill"65 :(D m= T I I V) m 1.500" 1.500" ®/9 ® ®®®®®®®®® I�1 (�- Q 3 u) _ -3 V)e ¢ o V) y2 �Z.714" o o v IV) 00.210' 00.188" DWG#: (TYp.) 0.188" (TYP.) A W D019 0.024"� SHEET: 6 OF 6