HomeMy WebLinkAboutProduct Approval - fixed window (2) NUAIMAPAUM I:UUN 11 r _ PRODUCT CONTROL SECTION DEPARTMENT OF REGULATOR`;AND LCONOMIC RESOURCES(RER) 11805 SW 26 Street Room 208 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidadL.gov/economl CGI Windows and Doors,Inc. 10100 NW 25`h Street Miami,FL 33172. SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials_ The documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as'described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION:Series 11450-Transom"Aluminum Fixed Window—L.M.T. APPROVAL DOCUMENT:Drawing No.W98-38,titled"Transom Lites,for Swing Doors",sheets 1 through 5 of 5,dated 05/02/98,with revision K dated 05119116,prepared by Al-Farooq Corporation,signed . and sealed by Javad Ahmad,P.E.,bearing the Miami-Dade County-Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING:Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/series, and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises and renews NOAP 15-0512.14 and consists of this page f and evidence pages E-1,E 2, E-3 and E-4,as well as approval document mentioned above_ The submitted documentation was reviewed by Jorge M.Plasencia,P.E. CIMMMCOU rr ��. NOA No.16-0523.02 / Expiration Date. November 19,2021 Approval Date: July 28,2016 i Page 1 OCP r CGI Windows and Doors,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NOA's No. 98-0608.21 and 03-0422.03) 2, Drawing No. W98-38,titled Series"Transom Lites for Swing Doors", sheets 1 through 5 of 5,dated 05/02/98,with revision K dated 05/19116,prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad,P.E. B. TESTS 1. Test reports on: 1)Uniform Static Air Pressure Test,Loading per FBC TAS 202-94 2)Large Missile Impact Test per FBC,TAS 201-94 3)Cyclic Wind Pressure Loading per FBC;TAS 203-94 along with marked-up drawings and installation diagram of a series 7500 PVC fixed window,to qualify DuPont"Butacite"PVB interlayer,Duraseal®and Super Spacer® insulating glass spacer,prepared by Certified Test Laboratories,Test Report No. CTLA-3056 WA,dated 03/03/15, signed and sealed by Ramesh C.Patel,P.E. (Submitted under NOA No. 15-0512.14) 2. Test reports on: 1)Uniform Static Air Pressure Test,Loading per FBC TAS 202-94 2)Large Missile Impact Test per FBC,TAS 201-94 3)Cyclic Wind Pressure Loading per FBC,TAS 203-94 along with marked-up drawings and installation diagram of a series 7400 PVC project out window, to qualify DuPont`Butacite"PVB interlayer,Duraseal®and Super Spacer®insulating glass spacer,prepared by Certified Test Laboratories,Test Report No. CTLA-3056 WB,dated 03/03/15, signed and sealed by Ramesh C.Patel,P.E. (Submitted under NOA No. 15-0512.14) 3. Test reports on: 1)Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2)Large Missile Impact Test per FBC,TAS 201-94 3)Cyclic Wind Pressure Loading per FBC,TAS 203-94 along with marked-up drawings and installation diagram of a series 238 aluminum fixed.window,to qualify DuPont"Butacite"PVB interlayer,Duraseal(D and Super Spacer®insulating glass spacer,prepared by Certified Test Laboratories,Test Report No. CTLA-3056 WC,dated 04116115, signed and sealed by Ramesh C.Patel,P.E. (Submitted under NOA No. 15-0512.14) 4. Test reports on: 1)Uniform Static Air Pressure Test,Loading per FBC, TAS 202-94 2)Large Missile Impact Test per FBC,TAS 201-94 3) Cyclic Wind Pressure Loading per FBC,TAS 203-94 along with marked-up drawings and installation diagram of an outswing aluminum door,prepared by Architectural Testing,Inc.,Test Report No.ATI-B5234A3-450-18, dated 12/13/11,signed and sealed by Vinu J.Abraham,P.E. (For reference only) (Submitted under NOA No. 11-1110.02) Jorge M.Plasencia,P.E. roduct Control Unit Supervisor NOA No.16-0523.02 Expiration Date: November 19,2021 Approval Date: July 28,2016 E-1 i CGI Windows'and Doors.Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED B. TESTS(coNumm) . 5. Test reports on: 1)Air Infiltration'Test,per FBC,TAS 202-94 2)Uniform Static Air Pressure Test,Loading per FBC,TAS 202-94 3)Water Resistance Test,per FBC,TAS 202-94 4)Large Missile Impact Test per FBC,TAS 201-94 S)Cyclic Wind Pressure Loading per FBC,TAS 203-94 6)Forced Entry Test,per FBC 24113.2.1 and TAS 202-94 along with marked-up drawings and installation diagram of a series 450 aluminum swing door w/sidelites and transom,prepared by Hurricane Testing Laboratory,Inc.,, Test Report No.HTL-0080-0304-11 dated 08/03/11,for specimens#1 through#15, signed and sealed by Vinu J.Abraham,P.E. (Submitted under NOA No. 11-1110.02) 6. Test reports on:1)Uniform Static Air Pressure Test,Loading per FBC,TAS 202-94 2)Large Missile Impact Test per FBC,TAS 201-94 3)Cyclic Wind Pressure Loading per FBC,TAS 203-94 along with marked-up drawings and installation diagram of an aluminum sliding glass door,prepared by Hurricane Test Laboratory,Inc., Test Report No. . HTL-0080-0402-02,dated 4/1/02,signed and sealed by Vi nu J.Abraham,P.E. (Submitted under NOA No. 03-0422.03) 7. Test reports on: 1)Air Infiltration Test,per FBC,TAS 202-94 2)Uniform Static Air Pressure Test,Loading per FBC, TAS 202-94 3)Water Resistance Test,per FBC,TAS 202-94 4)Large Missile Impact Test per FBC, TAS 201-94 5)Cyclic Wind Pressure Loading per FBC,TAS 203-94 6)Forced Entry Test,per FBC 24113.2.1 and TAS 202-94 along with marked-up drawings and installation diagram of an aluminum in/outswing door w/sidelites,by Hurricane Testing Laboratory,Inc., Test Report No.HTL-0080- 912-97,dated 09/23/97 thru 02/27/98 for specimen#1,2,3,SA, 513 and 5C, signed and sealed by Timothy S.Marshall,P.E. (Submitted under NOA No. 98-0608.21) 8. Tensile Test prepared by Metallurgical,Inc., Report No.8CM-709,dated 04/02/98, for aluminum samples,tested per ASTM E-8, signed and sealed by Frank Grate,P.E. (Submitted under NOA No. 98-0608.21) 9. Tensile Test prepared by Metallurgical,Inc.,Report No. 8CM 709,dated 10/02/98, for aluminum samples,tested per ASTM E-8 and Spectrographic analysis per ASTM E-415,signed and sealed by Frank Grate,P.E. (Submitted under NOA No. 98-0608.21) Jorge AL Plasencia,P.E. ' Product Control Unit Supervisor NOA No.16-0523.02 Expiration Date: November 19,2021 Approval Date: July 28,2016 E-2 f CGI Windows and Doors.Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED C. CALCULATIONS 1. . Anchor verification calculations and structural analysis,complying with FBC-5tb Edition(2014),dated 10/07/14,prepared by Al Farooq Corporation,signed and sealed by Javad Ahmad,P.E. (Submitted under previous NOA No. 14-1103.11) 2. Glazing complies with ASTM E1300-09 D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources(RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 14-0916.11 issued to Kuraray America,Inc.for their "SentryGlas®(Clear and White) Glass Interlayers"dated 06/25/15,expiring on 07/04/18. 2. Notice of Acceptance No. 14-0916.10 issued to Kuraray America,Inc,for their "Butacite®PVB Glass Interlayer"dated 04/25/15,expiring on 12/11/16. 3. Notice of Acceptance No. 14-0423.15 issued to Eastman Chemical Company(MA) for their Saflex CP—Saflex and Saflex HP Composite Glass Interlayers with PET Core"dated 06/19/14,expiring on 12/11/18. 4. Notice of Acceptance No. 15-1201.11 issued to Eastman Chemical Company(MA) for their"Saflex Clear and Color Glass Interlayers"dated 03/17/16,expiring on 05/21/21. F. STATEMENTS 1. Statement letter of conformance,complying with FBC-5th Edition (2014),and of no financial interest,dated 05/19/16,issued by Al-Farooq Corporation,signed and sealed by Javad Ahmad,P.E. (Submitted under previous NOA No. 14-110311) 2. Laboratory compliance letter for Test Report No.ATI_B5234.03-450-18,issued by Architectural Testing,Inc.,dated 12/13/11,signed and sealed by Vinu J.Abraham, P.E. (Submitted under NOA No. 11-1110.02) 3. Laboratory compliance letter for Test Report No.HTL-0080-0304-11,issued by Hurricane Test Laboratory,Inc.,dated 08/03/11,signed and sealed by Vinu J. Abraham,P.E. (Submitted under NOA No. 11-1110.02) 4. Laboratory compliance letter for Test Report No.HTL-0080-0402-02,issued by Hurricane Test Laboratory,Inc.,dated 11/26/02, signed and sealed by Vinu J. Abraham,P.E. (Submitted under NOA No. 03-0422.03) Jorge M.Plasencia,P.E. Product Control Unit Supervisor NOA No.16-0523.02 Expiration Date: November 19,2021 Approval Date: July 28,2016 E-3 CGI Windows and Doors,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBNHT rED F. STATEMENTS(coN umED) 5. Laboratory compliance letter for Test Report No.HTL-0080-912-97,issued by Hurricane Test Laboratory, Inc.,dated 09/23/97,signed and sealed by Timothy Marshal,P.E. (Submitted under.NOA No. 98 0608 21) 6. Laboratory compliance letter for Test Report No.8CM-709,issued by Metallurgical, Inc.,dated 0402/98, signed and sealed by Frank Grate,P.E. (Submitted under NOA No. 98-0608.21) 7. Test Proposal for the qualification of Butacite®PVB glass interlayer by DuPont as well as Duraseal®and.Super Spacer®Standard warm-edge flexible insulating glass spacers,dated December 16,2014,issued by REP,Product Control Section, signed by Jaime Gascon,P.E.;Supervisor,Product Control Section. (Submitted under NOA No. 15-0512.14) G. OTHERS 1. Notice of Acceptance No. 15-0512.14,issued to CGI Windows&Doors,Inc. for their Series"450-Transom"Aluminum Fixed Window-L.M.I.,approved on 09/10/1-5 and expiring on 11/19/16. orge M.Plasencia,P.E. Pro uct Control Unit Supervisor NOA No.16-0523.02 Expiration Date: November 19,2021 Approval Date: July 28,2016 E-4 ,0� .080 .160�•1 1.� I f C� MO O 4,� m -�I.778 •H18 928 .754 � •B28 OB744 k*- 6� � m m OGEE GLAZING BEAD OGEE GLAZING ADAPTER ,IN UL. GLASS ADAPTER }�k CGI-375 CGI-504 CGI-51a 0. t3 9 6063-TS 6083-Ts 5063-TB O V 0 .617 .67213 y1 .608 .030 .828 •090 =01 4 •1 �p .754 .742 O O S O.17 d O SD. GLAZING BEAD SO. GLAZING ADAPTER COI-396 CGI-519 N 6 6063-T5 6063-TB Q 2 4.462 1.918 Q " .125 1.Z70-�i O .750 1.102 .126 O U 1.812 C ,100 0 O 1.034 jf2ANS9M TOP & SOTTO M L2202— 6063-T6 C3 W DOOR HEAD 1.Z50� � 0 9 CGI-507 6083-T6 ,7F15 :— En O n ONM 4.522 �-.125 NOTES; .0 yi m n al 1M. H NNFI THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE �p r-Z REQUIREMENTS OF THE 2014 (5TH EDITION) FLORIDA BUILDING CODE N o �I BOs3-75 INCLUDING HIGH VELOCITY HURRICANE ZONE(HVHZ), o— .750 .12fi WOOD BUCKS BY OTHERS, MUST BE ANCHORED PROPERLY TO TRANSFER U 1.844 —.4A60 �� LOADS TO THE STRUCTURE. - 0 r ANCHORS SHALL BE AS LISTED.SPACED AS SHOWN ON DETAILS,ANCHORS TRANSOM ADAPTER EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. CGh510 ANCHORING OR LOADING CONDITIONS NOT SHOWN IN THESE DETAILS ARE 6063-Te NOT PART OF THIS APPROVAL. O .i ZS A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. u R 1.250-►I ALL SHIMS TO BE HIGH IMPACT. NON-METALLIC AND NON-COMPRESSIBLE c 4.812 MATERIALS INCLUDING BUT NOT UMITEO TO STEEL/METAL SCREWS,THAT o _ COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE 100. REQUIREMENTS OF THE 2014 FLORIDA BUILDING CODE &ADOPTED STANDARDS. .125 Toe TRANSOMS ARE RATED FOR LARGE AND SMALL MISSILE IMPACT. 2 a S e 4.582 SHUTTERS ARE NOT REQUIRED. g o- \\\\�ltl•l� TRANSOM STILE pD AN ..1fi0 CGI-500A �� .� �.'•., 2.z1e 6063 T6 1J17s PRODUCT REVISED �' ' czVa'' as eomplYixg with tho Florldo 83.c...p Dooddo 1.063 N0A-No. 16.0523.02 _ •�92 y . ,076 .062 .931 PxpI mtlon Dato 11/19/2021 .27G .465 >(iylll4 BY O'•. ATE OF ? drawing no. Miam Pmduet on �i ORIOt`. `� DOOR JAMB DOOR HEAD CAP DOOR STOP ♦ W98-38 6063575 B0635T5 6063-T5 - - '7 7,®NAL \v'\`\ sheet I of 5 r11111111 TRANSOM LITR LOAD CAPACrYY -PSF W' W W �V NOMINAL DIMS. MASS TYPB'A' WIDTH HEIGHT 7/16'&I'C0YPDSI78 PARIS OLAS9 TYPE'A1' GIA89 7YPH9'H'&1111' 9" A 20'MAK W-IN. L IN. FJCr.(+) 1M.(-) EXT.(+) I INT.(-) EXT•(+) 1NT,(-) 38 IOU 110.0 70.0 70.0 90.0 90.0 42 100.0 110.0 70.0 70.0 90.0 90.0 1Rj q 48 100.0 110,0 70.0 70.0 90.0 90.0 g c 54 24 100.0 110.0 70.0 70.0 00.0 90.0 5 , ,, 60 100.0 110.0 70.0 70.0 90.0 00.0 ywI 66 100.0 107.6 70.0 70.0 90.0 90.0 r-------1 It^------A-- -' -1 r--•----- C II ------I Jill r----'V 11 J- --- ii r---- 72 90.3 90J 70.0 70.0 90.0 90.0 1 1 36 100.0 110.0 70.0 70.0 90.0 90.0 II 11 j II II 11 /11 II 1\ j IIII p j II gp III 1 II91 / 11+� \ 1 IIII I 1 8 SV Cc 42 100.0 110.0 70.0 704 90.0 90.0 � II 1 1 II II 1 1 II 1 1 11 II 1 1 11 � n O It l 1 IIII 1 / IIII \ 0 II 11 ° 1 11 48 100.0 11010 70.0 70.0 90.0 90.0 II 1 1 II 11 1 1 II 1 1 II 11 1 e 11 11 1 1 11 11 1 /' 1 11 1 \ I II 1 ➢ II �. sa 30 Joao 110.0 70.0 Tao 90.0 90.0 q °u iii i/ \ it 60 10D.0 11010 70.0 70.0 20.0 90.0 II 1 1 II {II 1 1 II II 1 1 11 L p III 1 II IIII FI II II ° ° 11 .1�7 fpp_ ,J 86 100.0 103.6 70.0 70.0 80.0 90.0 tl p 1 1 11 y\ j IV j /p 11 II j p 11 Q b 01 72 88.8 86.5 70.0 70.0 90.0 90.0 11 1 II x 1 \ 1 II 1 / I II If I 1 II II 1 fill 1 II 1 1 till 36 100.0 110.0 70.0 70.0 90A 90.0 ll 1 1 It it \ 1 u 1 / 1 II 19, 1 {II Il j II I j \ j ll / 1 n x 1 1 11 !n m 42 100.0 110.0 70.0 7o.0 90.0 90.0 IIfill If 48 100.0 110.0 70.0 70.0 90.0 90.0 Q L 1 0 IppI ti \I II 1 j j 11 11 j j p ?RANSOM O.L OPG. O U 54 36 100.0 110.0 70.0 70.0 90.0 9G.0 If 11 L- -S,11 -•---y II II L----J II WIDTH WIDTH C 11 - II 11 11 IIII II 38' 24-7/8- - 60 100.0 110.0 70.0 70,0 90.0 90.0 �' V�"'�----- ---'---�1""�-""'-"'D U' vi 66 100.0 100.3 70.0 70.0 90.0 9D.0 42' 30-7/8- Z . pO 83.6 70.0 70.0. 80.1 86.1 RE'v 48 38-7/e 72 SEPARATE'CGI'N!.'.1,Ov1 rC� G 54" 42-7/B' ❑41 36 IOOA 110.0 70.G 70.0 90.0 90.0 FOR S SERIES 450 80" -7/6. IX C '42 85.7 84.3 70.0 70.0 85.7 90.0 COOR& MUWONS 48 42 85.7 94.3 70.0 70.0 85.7 9D.0 of 72' 60-7/8" N 54 86.7 94.3 70.0 70.0 85.7 90.0 3•CV 60 85:7 89.8 70.0 70.0 85.7 89.8 TRANSOM 0.1-Of •O 3 in 36 100.0 110.0 70.0 70.0 90.0 90.0 3 ANCHORS HEJOHr HEIGHT 0 C z IaJ. AT EACH SIDE In §p o 42 48 85.7 94J 70.0 70.0 85.7 90.0 W W W 12" 7-3/8' Z _ 48 75.0 62.5 70.0 70.0 76.0 82.5 3 FT. MAX. 6 FT.MAY. 3 FT.MAX, to, 13-3/8" U. o 54 75.0 82.5 70.0 70.0 75.0 824 24" 19-3/8" 35 100.0 11110 70.0 70.0 80.0 90.0 9" 121p0j1, 20"MAX. 3O' 26-3/8' C� A 42 54 85.7 94.3 70.0 70.0 85.7 90.0 8" _ 4 �n11 38" 31-3/0, 48 75.0 82.5 70.0 70,0 75.D 82.5 _y, 42' 37-3/8' 36 60 100.0 110.0 70.0 70.0 00.0 00.0 % 48 43-3/8" 42 65.7 94.3 70.0 70.0 85.7 90.0 C E /, El a 54 49-3j5' 5 i i so' 55-3/8' 0$ g NOTE: r--^--'-�r------y-7t--- ---�r---- --� �E o GLASS CAPACITIES ON THIS SHEET ARE BASED ON ASTM E1300-09 3 SEC. GUSTS i 1 1It11 eGl 11141 111 AND FLORIDA BUILDING COMMISSION DECLARATORY STATEMENT OCA05-DEC-219 c d^ . � ii° iinl/ niii \1iii1 'ii •H $;��� • till III Ilu l\ IIII /11111 10 III 1II� 1 \ IIII / IIIII ( � `7111N t Iy7j . PP., i 1y 9 .A II 1 011 e l l 11111 111 { u PRODUCT REVISED ��''vG'ENSF"••. '. .k y,-----I II as come In with the Florida n ,-ul a In x gu8ding one 1-----q( .-----�o-vo-T>WT---.--� MOA-No. 46-0623.02 70592 : Q k 2 ANCHORS 2-1/2" P�cplmtlon Data 11/19/2021 •5( /�� 'b AT EACH SIDE MIN. SPACING By a ` drawing no. , Mlam ro a Product Con '� '•.F<OR10.%'G,\`�� PMAX FOR THIS S_CONDITION = 72.3 PSF ����j�..... yy98 W9 2 01 5 3/16-ANN,GLASS 3/16°HEAT STREWO CLASS 3/16-ANN. GLASS p y ccS' 075"Interlayer 0758 Interlayer So ex CP With PEr Core Saflex CP With PET Cara 090'Interlayer Saflex Clear And Color Glass A OR Eastman Chemical Co.' OR'Eastman Chemical Co.' By'Eastman Chemical Co.' Z' m OR .090 ALUMINUM SHEET e�Intarlayer .090" 90"IGnclasrlayer 090'Interlayer C w ¢Sen Glas try Butocite PVB 1/4'PLYW000 1- By Kuraray Americo, Inc.' By'Kuroroy Americo, Inc.' By Kuraray America, Inc.' h, 3/16°ANN.GLASS 3/18°HEAT STREN'O GLASS .090 ALUMINUM SHEET BULB VINYL - BULB VINYL BULB VINYL 3/16-HEAT STREWD GLASS BULB VINYL d $ ` CGI-382 CGI-382 CGI-382 CGI-3B2 O u. 0Nti � � j� I N � II IIp❑, II III 0 I II c34 � \cart ��Y71 I I• X I I.I a��l SILICONE YI SIUCONE SILICONE 1V SILICONE a a m GE-1200 GE-1200 GE-1200 GE-1200 SETTING BLOCKS DOW 995 SETTING BLOCKS DOW 995 SETTING BLOCKS DOW 995 SERING BLOCKS OOW 995 EPDM DOW 899 EPDM DOW 899 EPDM DOW 899 EPDM DOW 899 DUROMETER BOtS OUROMETER 80*5 DUROMETER 801- DUROMETER 8035 m 2 PER LITE 2 PER LITE 2 PER LITE 2 PER LITE O V AT 1/4 POINTS ON AT 1/4 POINTS ON AT 1/4 POINTS ON AT 1/4 POINTS ON p C LITES WIDER THAN 36' UTES WIDER THAN 36" LITES WIDER THAN 36' - LITES WIDER THAN'36" ua'i GLASS TYPE 'A' -1ASCU a� 8' 7/16" OVERALL OMPOSRE PANEI Z p 7/16"OVERALL LAM.GLASS 7/16.OVERALL LAM.GLASS N O C3 Lu 1/8'OR t/a"TEMP.cuss TRANSOMS CAN BE GLAZED USING c AIR SPACE 1/8"OR 1/4"TEMP.GLASS SQUARE OR OGEE GLAZING BEADS/ADAPTERS O m AIR SPACE ; r%1'tj 3/16'ANN, GLASS 3/16"ANN.GLASS k. DOW SHEET - C "oI 075°Interlayer 0 r��_2 Saflex CP With PET Core .090"Interlayer D to 9 p By 'Eastman Chemical Co.' SaOax Gear And Color Glass VINYL Z p OR BY'Eastman Chemleal Co.' BULB—3 090" Interlayer OR CGI-3INUM SHEET U O� BULB VINYL SentryGlas 090'Irderlayer CGI—J82 By'Kuraray America,Inc.' BULB VINYL Butoeite PVB O . CGI-382 - By'Kuremy America,Inc.' 3/16'ANN.GLASS 3/16'HEAT STREN'D GLASS � YC❑ I I 'I LICONESETTING BLOCKSE-1200 EPDMOW 995 SILICONE SILICONE DUROMETER 80t5 899 io _m o GE-1200 SETTING BLOCKS GE-1200 2 PER LITE o d SETTING BLOCKS AT 1/4 POIMS•ALL SIZES .2 o 6 6!�c EPDM DOW 995 EPOM DOW 995 B� DUROMETER 80f5 DOW B99 DUROMErER 80t5 DOW 899 f OVERALL COMPOSITE PAN_FI 2 PER UTE %L EDGE SPACER 2 PER LITE AT 1/4 POINTS ALL SIZES ST. STEEL BY'CARDINAL' AT 1/4 POINTS ALL SIZESOR XL EDGE SPACER 111111111rrf7 ,1 ST.STEEL BY'CARDINAL'OR GLASS TYPE 'Al' DURASEAL BY'OUANEX' P CEN@"•• II GR GLASS TYPE B1° oRRASEAL BY'avANEx' PRODUCT REVISED �•' V F Lr 1"OVERALL INSUL LAM. GLASS SUPER SPACER BY 'OUANEX' as complying with the Florida _ $ 1"OVERALL INSUL,LAM. GLASS SUPER SPACER BY'OUANEX' Building Code — N 70582 L Noe-No. 16-0523.02 Expimtion Data 11/19/2021 TATE OF / � GLAZING OPTIONS illy "�.''•,!xoR.a! drawing no�. UMlam a m ue on o �ii �s '��`�� W98 38 /4f�OIII AfT4Lt���� sheet 3of5 •NOTE: •1/4"ULTRACON AS MFG. BY ELCO U ANCHORS MAY ALSO BE 1-3/4'MIN i-1/4'EMBED INTO MASONRY �t2 X 1-1/4'SMS DIRECTLY TO MASONRY EDGE GIST• 6' &9"FROM CORNERS&20'O.C. WITH 1/4'MAX.SHIM SPACE a4'� a a• a m .320H WOOL PILE W/CENTERFIN 0 WEATHERSEAI, ,i,Li;�� ',F:^t E=�' w I (ULTRAFAB#3032) •'a,f;;F:<.•. 0 a• 0 0 p�`L" IL 9 O'oQ N .. a 00 1-e07 COT.ROD CGI-503U(A-MESSURY �ER O 2010) G'a N I I I GE 1200 SILICONE TYP. O C FRAME CORNER DETAIL CGI-5i1 Z p` . CCI-503 O �yt CGI-510 p. V� 4 ALL CORNERS TO BE SEALED WITH O a c[A LOW MODULUS SILICONE SILPRUF OR EQUIVALENT W 3 NM #10 X 1'SMS 5 p M n 0 6"FROM ENDS& 12'D.C. COR _O Z 3/16 X 1"KWIK-FLEX S.D.SCREWS I I I N O_ e12 X 1-1/4"SMS 0 5'FROM ENDS& 12'O.C. 11 I I o 9-9 I Vo I�rx_s—z_sl�l I 1 n • I� �i U I I I ¢ $13 II ° �"iu •m �9sE� ' PRODUCT REVISED as COMPi I with the Florida Building Code _ 8 NOA-No. 16-0523.02 1-1/2'X 1-1/2'X 3/16" 191110 r _ .ALUM PLATE expirntt°nOato11119T2021 A�CF drawing no. WOOD=BUCKS B SYSTEM AND T ST USTAINRLOADS By ' i \ W98-38PANEL CORNER DETAIL TRANSOM CORNER DETAIL TRUCTURE. ml 'dopra u° con � / 1G'T�� sheet 4 of 5 �ry 11IIN 1/4"ULTRACON •NOTE: a 1-1/4"EMBED INTO MASONRY ANCHORS MAY ALSO BE 6'FROM CORNERS &24-3/16.O.C. DIRECTLY TO MASONRY n 1-3/4-MIN. EDGE DIST. WITH 1/4"MAX. SHIM SPACE alo (SEE DETAIL BELOW) USE APPROVED MULLION �i g n zJz w 0 F h Q O FOAM TYPE 0 6'FROM C O ORNERS 1/4-MAM' WEATHER SEAL '&24-3/18" SHIMS TYP.AT PERIMETERS O S Nair; CGI-511 OF TRANSOM CCI-511 CL C a_�� cy jr — GLASS SITE TYP. Of •�e Z$ D' h --- o c vl O r m J•r.; O )')"• C01-SODA C 31-500A .,f•:•Y VINYL BULB TYP. In O Lj Lj • r i:- CGI-509 GE 1200 SILICONE TYP, CCI-609 EXTERIOR O O N N crIn h 3 M I B 14SMS J 03,�N ®6'FROM CORNERS C: C Z�1 W &24-3/16'O.C. N O c 8. 20" CGI-511 ZZ o-.^.. MAX. U O �{ B" L INNffO DOD STRUCTURE n 1-3/8"MIN.EMBED c_______ THR WOOD BUCK INTO MASONRY o 15 'T p - -�1ir____j ttMII 1-1/4'MIN. MASONRY EMBED II s /1i\ i 'I 1-3/4"MIN.EDGE DIST. A7 3"O.C.SPACING II 0 / I111 \ 11117- It8 0 II O O ADDL.ANCHOR READ. FOR DOOR HEIGHTS X 9 FT. c o 1 y I o II I 1 e I CCI-500A COI-500A o x x nl\ lue /el' III \ III n / I n ccl-6D9 nu11 u l I51 III . `� •, aCEN@F'';"L n ii NO—TES; PRODUCT REVISED j �_ �y n :11,Id._..__.a u / ( ) as c a In gowiththoFlorida _* - 1�s a 11 II I 1 4" DIA. ll A ON BY -0' Fuv177 KSI,F 155 KSI Cod ` 1-3/4" MIN. EDGE DISTANCE INTO CONC. & MASONRY NOA-No. 16-0523.02 �f ANCHORING DETAIL FOR TRANSOM ENDS 3/4" MIN. EDGE DISTANCE INTO WOOD Expiration Date IIM 9/2021 FOR TRANSOMS WITHOUT SIDELITES :<41 drawing no. AND XX DOORS BELOW CONCRETE f'c - 3000 PSI MIN. BY.- Protluet Control G C-80 HOLLOW/FILLEDW98-38 BLOCK f'm = 2000 PSI MIN. ' A�1���`` sheet 5 of 5