HomeMy WebLinkAboutRevision 20-0633 - REV2 S&S - 03-09-21GENERAL NOTES SUMMARY OF WORK: 1. Project Description: New 1-story residence. 2. Work Involved: a. Roof: Asphalt shingles, #30 felt, exterior sheathing, pre-engineered trusses, R-30 Blown Insulation for A/C space. b. Walls: i. Exterior: 8" CMU walls with exterior stucco finish and min. 1" Thk Rigid Board Insulation, 1X P.T. furring and 1/2" drywall at the interior side ii. Interior: Metal studs, batt insulation, with 1/2" drywall each side c. Ceiling: i. 5/8" drywall - see plans for trays, coffers and vaults ii. Exterior ceiling finish shall be I/2" thick stucco on high rib lath attached per note on wall section. d. Foundation: Concrete thickened slab edge and 4" concrete floor slab e. Mechanical: i. Provide (1) unit per plans ii. Exhaust all bathrooms and dryer f. Electrical: i. Provide power and lighting per plans ii. Provide 200 amp service and 40 slot panel g. Plumbing: i. Provide water heater per plans ii. Provide sanitary lines per plans and risers iii. Provide plumbing fixtures per plan h. Work completed shall meet all local and state building code requirements. COORDINATION: 1. Contractor shall verify existing site conditions of project location prior to commencement of work. 2. Contractor shall coordinate and verify all utility requirements, compatibility and location of projected utilities of project, as shown on the drawings. 3. Contractor shall verify space requirements and location of project utilities. 4. Contractor shall field verify all dimensions of project. Do not scale drawings. 5. Contractor shall notify Architect of any discrepancies in drawings and/or specifications of project. Commencement of the work without proper notification to the Architect, the contractor will assume responsibility of work preformed. 6. Contractor shall notify the Architect, when the full intent of the drawings and/or specifications is not clear. Commencement of the work without proper notification to the Architect, the contractor will assume responsibility of work preformed. 7. Owner and Contractor shall coordinate Schedule of Values, Application of Payment, Construction Cost and any other fees related to this project. CHANGE PROCEDURES: 1. Architect will submit Supplemental Instructions for minor changes. 2. Contractor may propose changes by submitting a request for change to Architect. Architect and Owner shall give written approval for all changes made by the Contractor. Commencement of the work without written approval from Architect and Owner, the contractor will assume responsibility of work preformed. SUBMITTAL: 1. Prior to construction Architect and Owner shall submit a list, to the Contractor of required shop drawings submittals for this project. 2. Prior to construction Architect and Owner shall submit a list, to the Contractor of all required testing for this project. Contractor shall be responsible for the cost of any testing requested by the Owner. TEMPORARY FACILITIES: 1. Contractor shall provide and maintain access to the site of the project. 2. Contractor shall coordinate with Owner for temporary facilities requirements, if required for this project. 3. Contractor shall be responsible for maintaining a clean and safe construction site. 4. Contractor is responsible for the removal of all construction debris. MATERIALS: 1. Store and protect all project products and materials in accordance with manufacturer instructions. Products and materials of this project shall be installed free of damage. PROJECT INFORMATION DESIGN PARAMETERS: Florida Building Code (6th Edition, 2017) Florida Residential Code (6th Edition, 2017) Florida Existing Building Code (6th Edition, 2017) Florida Plumbing Code (6th Edition, 2017) Florida Mechanical Code (6th Edition, 2017) Florida Fuel Gas Code (6th Edition, 2017) 2014 National Electric Code 2012 Florida Accessibility Code (6th Edition, 2017) Florida Energy Code (6th Edition, 2017) Florida Fire Prevention Code (6th Edition) 2002 National Fire Alarm Code - (NFPA-72) 2002 Fire Sprinkler Code - (NFPA-13/13R/13D) 2002 Standard for Automatic Fire Suppression Systems (NFPA-17/17A) 2000 Standard for Safeguarding Const., Alterations, & Demo Operations (NFPA-241) Building Design: Ultimate Wind Speed: Nominal Wind Speed: Building Category: Wind Importance/Use Factor: Internal Pressure Coefficient: Building Mean Height: Roof Overhang: Roof Pitch: Garage Design Pressure: 120 sqft. Door Design Pressure: 50 sqft. Window Design Pressure: 20 sqft. Exposure: Design Loads: Impact Protection: nr(-1 I DA KIrV - R3 One -Family Residence CONSTRUCTION: Enclosed 160 mph 3 second gust 124 mph II 1.0 +/-0.18 15'-6" 1'-4" 5/12 Int. Zone (+26.3/-29.3) Ext. Zone (+30.0/-36.7) Int. Zone (+31.6/-34.6) Ext. Zone (+31.6/-39.8) Int. Zone (+33.7/-36.7) Ext. Zone (+33.7/-44.0) C Roof Dead Load/Live Load Floor Dead Load/Live Load Hurricane Shutters Type V Unprotected, Unsprinklered Ext. brg walls - CMU Pre -fabricated wood roof trusses Int walls -metal stds & drywall AREA TABULATIONS: (include exterior walls A/C space: 1,852 gross sqft. Garage: 469 gross sqft. Covered Patio: 144.5 gross sqft. Front Entry 56 gross sqft. Total New Bldg. Area: 2,521.5 gross sqft. 15/40 psf 15/30 psf Product Approval Submittal Affidavit Bldg Address: 8682 Lonesome Pine Trail Contractor: Homecrete Homes Opening Schedule: Swing Doors, Overhead Doors, Sliding Doors, Fixed Glass, Windows, & Skylights: FL# or Product Model # Manufacturer Glass Attachment Method Type, Building Design Product Design Miami -Dade Description Size, Spacing, & Embedment Pressure Pressure FL# 17234.1 SINGLE -HUNG 610 Custom Windows Non -Impact Rated Installation shall stricty adhere to product approval See Cover Sheet +50 / -50 WINDOW Aria and Doors Low E 270 FL# 17234.1 into 1X P.T. wood buck Anchors: 3/16" anchors @ Head, Sill and Jamb Attachment: Head - 6" max from corners (1) at midpoint Jamb - 6" max from corners Jamb - 14.5" max O.C. Jamb - 3" either side from center Embedment: 1-1/4" min into concrete thru 1X Use 3/16" dia. Elco Ultracon Anchors FL# 12856.2 HURRICANE Safety Town & Country Installation shall stricty adhere to product approval See Cover Sheet +54.0 / -54.0 SHUTTERS Edge Industries FL# 12856.2. 1/4" all points solid set anchor x 7/8" embed 2" min. edge distance - max spacing of 12" O.C. FL # 20468.1 FIBERGLASS Smooth Star Thermatru Corp. N/A Tapcons shall be spaced as per product approval See Cover Sheet +67.0 / -67.0 ENTRY DOOR Opaque on Sheet 8 of 11 Anchors: 1/4" X 3" Tapcons @ Head and Jamb Buck Attachment: Head - 4" max from corners Jamb - 4" max from corners Jamb - 13.00" max O.C. Frame Attachment: Head - 6" max from corners Jamb - 6" max from corners Jamb-14.00" max O.C. Embedment: 1-1/2" min into concrete FL# 20834.2 S.G.D. 880 Custom Windows Non -Impact Rated Installation shall stricty adhere to product approval See Cover Sheet +65.0 / -65.0 NON - IMPACT SGD and Doors Low E 270 FL# 20834.2 into 2X P.T. wood buck Anchors: 1/4" anchors @ Head, Sill and Jamb Attachment: Head/Sill - 6" max from corners Head/Sill - (1) mid -span of door panel Head/Sill - (2) @ 3" O.C. sides at center Jamb - 6" max from corners Jamb - 21'max O.C. Embedment: 1-1/4" min into concrete Use 1/4" dia. ITW Tapcons Embedment: 1-3/8" min into 2X Use #12 wood screw anchors FL# 16546.5 GARAGE DOOR CLOPAY CLOPAY N/A Attach track as per Product Approval and Track See Cover Sheet +36.0 / -42.0 MODEL 73 W6 Supplement Guide - Attach Buck W/ 5/8"0 x 6" sleeve anchors @ 18" O.C. Product Model # Manufacturer Attachment Method Type, Building Design Product Design Size, Spacing, & Embedment Pressure Pressure Mullions Tube Mullion Custom Windows 3" Tube Mullion - Installation shall strictly adhere See Cover Sheet +65.0 / -65.0 FL # 9520.1 and Doors to Product Approval FL# 9520.1 Use 3/16" dia. ITW Tapcons at each hole P vid mi u f 1- 4" be en Roof Heritage Tamko Attach Shingles with (Zinc Coated) Roofing Nails 12 Gauge, See Cover Sheet N/A Asphalt with 3/8" dia. heads, long enough to penetrate through plywood Shingles 1/4". use (4) nails per shingle, placed in nail line 7-3/8" & 7-1/2" FL # 18355.1 in field and (1) each side 1" from edge Id ing Stucco 5/8" Thick Light Textured Stucco on Typical Concrete Block Const. See Cover Sheet N/A Soffit Universal Plygem Siding Group Attach with 16 gauge x 1" staples into min 3/4" See Cover Sheet N/A Vinyl 12" Mastic Soffits spruce -pine -fir FL # 23352.1 Refer to Florida Product Approval for additional information I have reviewed the above product approval information and and approved it. Name: Nicole L. Norton/n2 architecture + design Signature: Certification Number: AR 91827/ AA26002853 Date: INDEX OF DRAWINGS Revised 09-Mar-21 V O1 O Sheet Sheet Title + + + C1 Cover Sheet, General Information + Notes ■ ■ ■ Al Floor Plan, Details + Notes ■ ■ A2 Foundation Plan Details + Notes ■ A3 Building Elevations ■ S1 Roof Framing Plan NJ I S2 Structural Details ■ ■ ■ P1 Plumbing Plan, Schedules + Notes ■ E1 Electrical Plan Schedules + Notes SYMBOLS Digitally signe Nicole L. Nicole L. Nort( # Date: 2021.03. O Window AXX DetailNorton 13:00:34-05'01 ## Door ## Keyed Note xxx Room Name XX.X Interior Elevation 0 Wall Type XXX Exterior Elevation AX.X Wall Section AX.X Building Section 0 Revision 0 Miscellaneous Key PROJECT CONTACTS OWNER/CONTRACTOR: Homecrete Homes Robert Cenk 2162 NW Reserve Park Trace Port St Lucie, Florida 34986 (772) 873-6707 ARCHITECT: n2 architecture + design Niki L. Norton, R.A. 2081 SE Ocean Blvd. Suite 1A Stuart, Florida 34996 (772) 220-4411 LOCATION MAP Oil}Jt }i; I � 4.1 � r r�lG + K I r ,r1.;r ��r. ..-� v-•s - • .ti .'�.. r w PROJECT LOCATION R# y bhf'. #il1f .�°il' +•.fir. •" .r `',' i ., =r +F '� • i 11�f ' IY �-ram._-•_-n.��..Jr.-.--i- _�_. -_.. ..�...�Y- .__�� V - � T�..}! r - C O C U N} LA L O �p .� t _ C � L i 2-O o '0 Q C O N L O w N L o m 3 V1 i -O a.-. C U1 6 to 1 a o m T O a� C VUi O -C f6= 00,- O L C Q . o "a +°�+ C C: N O N y L T= L E2 > Q Qro � .L ='L C O y, 'O - 50 ,O L O O (n -C L 3 - -fO ^ L.L S� 5 u� 3u`U LA 0 fu o a (1)+� C _ C U C C U U Q ouQ_6 EaQ U c7 O C (n LL N -6� N L n L C v ca + nI Tao � a) U) 70 E - E o + O N U � U O G� U s_ (U signed and sealed by N6COLE NORTON, RA, LEER AP using a Diaital Signawre and Date. Printed Copies are nca conWefed 51ned bntl sealed and ehe signature most be vefifred on any electronic coples- W U Q� L. Ln V -0�fa O L O W r• W a -0 U) Eo �I.L� Ln a-' N 0 U L M L L U O J .W 00 W N 00 Ia L M� W Z W U_ Rev. # Date 25-Aug-20 Client + Bldg. Dept. Revisions 2 09-Mar-21 Client Revision Project Number 20-0633 Status CD Issue date 23-Jun-20 Sheet C 1 Cover Sheet