Loading...
HomeMy WebLinkAboutAPPROVED Design Pressure Report (Rannacher) - Master Craft Aluminum Products Property Information Building Information Owner: Rannacher Wind Zone: 160 MPH. Address: 121 Lagos del Norte Exposure Category: B Ft Pierce,Fl 34951 Minimum Building Dimension: 24 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 53 62 1 30.7 -33.5 2 Int 26 38 7 32.5 -35.2 3 Int 26 38 7 32.5 -35.2 4 Int 74 62 7 30.0 -32.8 5 End 113 84 7 28.5 -35.5 6 End 101 84 7 28.7 -36.0 7 End 108 84 7 28.6 -35.7 8 Int 53 55 7 31.0 -33.7 9 Int 53 55 7 31.0 -33.7 Prepared in accordance with:ASCE 7-16,Chapter 30. Wind Loads-Components and Cladding. 7th Edition(2020)Florida Building Code. Paget of 1