Loading...
HomeMy WebLinkAboutAPPROVED Design Pressure Report (Justis) - Master Craft Aluminum Products Property Information Building Information Owner: Justis Wind Zone: 160 MPH. Address: 62 Mediterranean Blvd E Exposure Category: B Port St Lucie,Fl 34952 Minimum Building Dimension: 24 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 End 108 84 7 28.6 -35.7 2 End 106 84 7 28.6 -35.8 3 Int 106 84 7 28.6 -31.4 Prepared in accordance with:ASCE 7-16,Chapter 30. Wind Loads-Components and Cladding. 7th Edition(2020)Florida Building Code. Page 1 of 1