HomeMy WebLinkAboutAPPROVED Design Pressure Report (Justis) - Master Craft Aluminum Products Property Information Building Information
Owner: Justis Wind Zone: 160 MPH.
Address: 62 Mediterranean Blvd E Exposure Category: B
Port St Lucie,Fl 34952 Minimum Building Dimension: 24 ft.
Mean Roof Height: 15 ft.
Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 End 108 84 7 28.6 -35.7
2 End 106 84 7 28.6 -35.8
3 Int 106 84 7 28.6 -31.4
Prepared in accordance with:ASCE 7-16,Chapter 30. Wind Loads-Components and Cladding. 7th Edition(2020)Florida Building Code.
Page 1 of 1