HomeMy WebLinkAboutblower doorR. EN Ij I L'OI INC & LI`vy U-MU T 1. 111 Vi Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 611 Edition Jurisdiction: Permit #: f Job Information Builder: K Hovnanian Community: �� ^� Lot: L(Y Unit: Address: ,,�J ` •-� --1 AP/14 IM 1r)MEMEN City: ��-}- �'. State: FL Zip:1 ,51 House S.F. Avg. Ceiling Height: Total Volume: (.� 31611 Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method 0 PRESCRIPTIVE METHOD The building or dwelling unit shall be tested and verified as having an air leakage rate or not exceeding 7 air change per hour at a pressure of 0.24rich w.g, (50 pascals) in climate zones 1 and 2. Q�Ze PERFORMANCE OR ERI METHOD -The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50) value, as shown on FORM R405"2017 (Performance) or R4W2017 (ERI), section labeled as infiltration, sub- section ACH. ACH(50) specified on Form R40520174nergy Calc (Perf'ormonce) or R406-2017 (ERI); Pressure & Flow Data (For Single Point) Test # House Pressure: Pascals Flow: CFM (50) Ring Used r ACH50 = CFM (50) x 60 / House Volume = L) Method for calculating building volume: 0 Retrieved from architectural plans PASS ❑ FAIL Cade Software calculated ❑ When ACH(50) is less than 3, Mechanical Ventilation installation must Field measured and calculated be verified by building department. Testing, Testing shall be conducted in accordance with ANSI/RESNI T/ICC 380 and reported at a pressure or 0.2 inch w.g, (50 pascals), Testing shall ble conducted by either Individual as defined In Section 553,003(5) or (7), Florida Statues, or individuals licensed as set forth in Section 480,105(3)(f), (g), or (I) or an approved third party, A written report of the results of the test shall be signed by the party conducting the test and provided to the code ofCial. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope, Testing Company , Company Name: RunBrook, LLC Phone: 561-510-5715 1 hereby verify that the above Air Leakage results are in accordance with the 2017 61" Edition Florida Building Code Energy Conservation requirement according to the compliance method selected above. / 8b, Signature of Tester: Date of Test: / Printed Name of Tester: Frank Costagliola License/Certification #: 3243649 Issuing Authority: RESNET UNBROOK Duct Leakage Test Report GREEN BUILDIN & ENERGYTESTING Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition