HomeMy WebLinkAboutCT Shingle NOANEMO I etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
to (203) 262-9245
ENGINEER EVALUATE TEST CONSULT
REPORTEVALUATION
CertainTeed, LLC Evaluation Report 3532.09.05-R17
20 Moores Road FL5444-R16
Malvern, PA 19355 Date of Issuance: 09/22/2005
(610) 893-5400 Revision 17: 07/24/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 7t' Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION: CertainTeed Asphalt Roof Shingles.
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1 / R905.2.6.1
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEW ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOletc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 14.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert
Nieminen, P.E. on 07/24/2020. This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
02018 NEMO ETC, LLC
ON EMO I etc.
TABLE 1: ASPHALT SHINGLE COMPONENTS
Type
Product
Description
Material
Standard
Plant(s)
Fiberglass reinforced starter shingle,
High -Performance Starter
measuring 10" x 36", for use with
ASTM D3462
NC
Grand Manor' and Highland Slate°
Fiberglass reinforced starter shingle,
measuring 13-1/4" x 40", with a
Presidential® Starter
reinforcement on the underside, for
ASTM D3462
CA(F)
use with Presidential Shake' and
Presidential Shake® TL
Starter
Strips
Presidential® Starter IR
Fiberglass reinforced starter shingle,
measuring 13-1/4" x 40", for use with
ASTM D3462
CA(F)
Presidential Shake® IR
SwiftStart® Starter Shingle
Fiberglass reinforced starter strip,
measuring 15-1/4" x 38-3/4"
ASTM D3462
MN
Fiberglass reinforced starter shingle,
Universal Starter
measuring 7" x 36", for use with
shingles measuring 12" x 36" having a
ASTM D3462
NC
weather exposure < 5"
CT 20'"
LA, NC
CT 20'" Metric
OR
Fiberglass reinforced, 3-tab asphalt
roof shingle
ASTM D3462
XT' 25
LA, MN, NC, OH
XT' 25 Metric
OH, OR
XT'"" 30 IR
LA
Highland Slate°
Fiberglass reinforced, 4-tab asphalt
roof shingle
ASTM D3462
NC
Arcadia'"
CA(F)
Belmont®
NC
Belmont® IR
NC
Carriage House"
NC
Grand Manor'
NC
Landmark®
CA(W), GA, LA, MA, MO,
MN, NC, OH, OR, TX
Landmark" Pro
CA(W), GA, MA, MO, MN,
OH, NC
Asphalt
Fiberglass reinforced, laminated
asphalt roof shingle
ASTM D3462
Landmark' Pro Architect 80
OR
Shingles
Landmark Pro Solaris°
CA(W)
Landmark® Premium
CA(W), MA, MN, OR, NC
Landmark Solaris°
CA(W), OR
Landmark Solaris° Gold/Platinum
OR
Landmark® TL
CA(F)
Landmark® TL Solaris
CA(F)
NorthGate®
Fiberglass reinforced, laminated, SBS
modified bitumen roof shingle
ASTM D3462
MN, OR
Presidential Shake°
CA(F), MN
Presidential Shake' IR
MN
Fiberglass reinforced, architectural
asphalt roof shingle
ASTM D3462
Presidential Shake' TL
CA(F), MN
Presidential Solaris°
CA(F)
Presidential TL Solaris
CA(F)
Patriot
Fiberglass reinforced asphalt roof
strip -shingle; laminated appearance
ASTM D3462
OH, OR
Note: Any of the above listed shingles may be produced in AR (algae resistant) versions
NEMO ETC, LLC
Certificate of Authorization #32455
7T" EDITION (2020) FBC NON-HVHZ EVALUATION
CertainTeed Asphalt Roof Shingles
Evaluation Report 3532.09.05-R37
FL5444-R16
Revision 17: 07/24/2020
Page 3 of 14
ONEMO I etc.
TABLE 1 (CONTINUED): ASPHALT SHINGLE COMPONENTS
Type
Product
Description
Material
Standard
Plant(s)
Hip &
Ridge
Shingles
Shangle Ridge°
Fiberglass reinforced accessory
shingles for hip and ridge installation
ASTM D3462
NC
Shadow Ridge°
ASTM D3462
MA, MN, NC, OH
Shadow Ridge° Metric
ASTM D3462
OR
Cedar Crest®
None
NC
Cedar Crest® IR
None
NC
NorthGate® Ridge
ASTM D3462
OR
NorthGate® Accessory
ASTM D3462
MN
5.1 This is a Building Code Evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -
Dade Counties).
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 Wind Classification: Refer to Section 6 for installation requirements to meet wind classifications.
TABLE 2A: WIND CLASSIFICATIONS, ASPHALT SHINGLES
Product
FBC Table 1507.2.7.1 or R905.2.6.1
CT 20TI
ASTM D3161(F) & ASTM D7158(H)
CT 20T" Metric
ASTM D3161(F) & ASTM D7158(H)
XT'^" 25
ASTM D3161(F) & ASTM D7158(H)
XT"" 25 Metric
ASTM D3161(F) & ASTM D7158(H)
XT"" 30 IR
ASTM D3161(F) & ASTM D7158(H)
Arcadia"
ASTM D3161(F) & ASTM D7158(H)
Belmont®
ASTM D3161(F) & ASTM D7158(H)
Belmont® IR
ASTM D3161(F) & ASTM D7158(H)
Carriage House°
ASTM D3161(F) & ASTM D7158(H)
Grand Manor®
ASTM D3161(F) & ASTM D7158(H)
Landmark'
ASTM D3161(F) & ASTM D7158(H)
Landmark® Pro
ASTM D3161(F) & ASTM D7158(H)
Landmark' Pro Architect 80
ASTM D3161(F) & ASTM D7158(H)
Landmark Pro Solaris®
ASTM D3161(F) & ASTM D7158(H)
Landmark® Premium
ASTM D3161(F) & ASTM D7158(H)
Landmark Solaris°
ASTM D3161(F) & ASTM D7158(H)
Landmark Solaris° Gold/Platinum
ASTM D3161(F) & ASTM D7158(H)
Landmark° TL
ASTM D3161(F) & ASTM D7158(H)
NorthGate°
ASTM D3161(F) & ASTM D7158(H)
Presidential Shake'
ASTM D3161(F) & ASTM D7158(H)
Presidential Shake° IR
ASTM D3161(F) & ASTM D7158(H)
NEMO ETC, LLC Evaluation Report 3532.09.05-R37
Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL5444-1116
CertainTeed Asphalt Roof Shingles Revision 17: 07/24/2020
Page 4 of 14
5.5.1
5.5.2
5.5.3
5.5.4
5.5.5
OMEMO I etc.
TABLE 2A: WIND CLASSIFICATIONS, ASPHALT SHINGLES
Product
FBC Table 1507.2.7.1 or R905.2.6.1
Presidential Shake° TL
ASTM D3161(F) & ASTM D7158(H)
Presidential Solaris®
ASTM D3161(F) & ASTM D7158(H)
Presidential TL Solaris
ASTM D3161(F) & ASTM D7158(H)
Highland Slate°
ASTM D3161(F) & ASTM D7158(H)
Patriot
ASTM D3161(F) & ASTM D7158(H)
Classification by ASTM D7158:
ASTM D7158, Class H applies only to exposure category B or C and a building height of 60 feet or less. Calculations
by a qualified design professional are required for conditions outside these limitations. Contact the shingle
manufacturer for data specific to each shingle.
Analysis in accordance with ASTM D7158 indicates the measured uplift resistance (RT or RA) for the CertainTeed
asphalt Roof shingles listed in Table 1 (except Presidential Solaris°, Landmark Pro Solaris° and Landmark Solaris°
Gold/Platinum) exceeds the calculated uplift force (FT) under the following conditions:
• maximum design wind speed of Vasd = 150 mph (VUit = 194 mph)
located in Exposure D conditions
no topographical variations (flat terrain)
• having a mean roof height less than or equal to 60 feet.
The shingles (except Presidential Solaris°, Landmark Pro Solaris° and Landmark Solaris® Gold/Platinum) are
permissible under Code for installation in these conditions using the installation procedures detailed in this
Evaluation Report and CertainTeed minimum requirements, subject to minimum codified fastening requirements
established within any local jurisdiction, which shall take precedence.
TABLE 213: WIND CLASSIFICATIONS, STARTER STRIPS AND HIP & RIDGE
Type
Product
FBC Table 1507.2.7.1 or R905.2.6.1
High -Performance Starter
ASTM D3161, Class F
Presidential° Starter
ASTM D3161, Class F
Starter Strips
Presidential° Starter IR
ASTM D3161, Class F
SwiftStart® Starter Shingle
ASTM D3161, Class F
Universal Starter
ASTM D3161, Class F
Shangle Ridge®
ASTM D3161, Class F (sealant required, See Section 6)
Shadow Ridge® (NCproduction)
ASTM D3161, Class F
Shadow Ridge° (MA, MN or OH production)
ASTM D3161, Class F (sealant required, See Section 6)
Hip & Ridge
Shadow Ridge ® Metric (OR production)
ASTM D3161, Class F (sealant required, See Section 6)
Shingles
Cedar Crest'
ASTM D3161, Class F (sealant required, See Section 6)
Cedar Crest° IR
ASTM D3161, Class F (sealant required, See Section 6)
NorthGate® Ridge
ASTM D3161, Class F
NorthGate® Accessory
ASTM D3161, Class F
High -Performance Starter shingles are limited to use with Grand Manor® and Highland Slate® shingles.
Presidential® Starter shingles must be applied using two (2) overlapping layers and are limited to use with
Presidential Shake® and Presidential Shake® TL shingles.
Presidential® Starter IR shingles must be applied using two (2) overlapping layers and are limited to use with
Presidential Shake® IR shingles.
Universal Starter shingles are limited to use with CertainTeed shingles measuring 12" x 36" having a weather
exposure < 5".
NEMO ETC, LLC Evaluation Report 3532.09.05-1137
Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL5444-R16
CertainTeed Asphalt Roof Shingles Revision 17: 07/24/2020
Page 5 of 14
OMEMO I etc.
5.6 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3.
Refer to the Product Approval of the component manufacturer for components that are produced by a Product
Manufacturer other than the report holder on Page 1 of this Evaluation Report.
6.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle
manufacturer's minimum requirements.
6.1.1 Underlayment shall be acceptable to CertainTeed, LLC and shall hold current Florida Statewide Product Approval,
or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3.
6.2 Installation of asphalt shingles shall comply with the CertainTeed, LLC current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or Section R905.2.6 and the minimum
requirements herein.
6.2.1 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or
R905.2.5. Staples are not permitted.
6.2.2 Where the roof slope exceeds 21 units vertical in 12 units horizontal, use the "Steep Slope" directions.
6.3 CertainTeed asphalt shingles are acceptable for use in reroof (tear -off) or recover applications, subject to the
limitations set forth in FBC Section 1511 or R908 and CertainTeed published installation instructions.
6.4 HIGH-PERFORMANCE STARTER:
6.4.1 Eaves: For the first starter shingle in each roof corner, use five (5) nails as shown below. All other starter
shingles require four (4) nails per shingle. Nails must be of sufficient length to penetrate into the deck 3/4" or
through the thickness of the decking, whichever is less. Nails are to be 11 or 12 gauge, corrosion -resistant
roofing nails with 3/8" heads. Apply the 10" starter shingle with its factory -applied sealant stripes at the
shingle's lower -most edge and nail firmly into the roof deck as near as possible *(maximum 3") to the eaves
edge while avoiding the sealant. With the starter shingle well fastened to the deck and the sealant low on the
starter shingle, it can firmly adhere to the first course shingles. *If nailing within 3" is not possible, nail as
closely as possible, then lift and adhere the starter shingle to the underlayment and to the supporting structure
with CertainTeed FlintBondl" Asphalt Roofing Cement -Caulk Grade, or approved equal.
Rakes: Prior to installation of the field shingles, starter shingles may be applied up the slope along the rake edge
with sealant edge placed closest to the rake edge. Fasten as indicated below.
HIGH-PERFORMANCE STARTER SHINGLES
36
1 316" (Max T )
NEMO ETC, LLC
Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION
CertainTeed Asphalt Roof Shingles
Evaluation Report 3532.09.05-R17
FL5444-R16
Revision 17: 07/24/2020
Page 6 of 14
ON EMO I etc.
6.5 PRESIDENTIAL® STARTER AND PRESIDENTIAL® STARTER IR:
6.5.1 General: These shingles shall be applied by using two (2) overlapping layers. Begin application of the
bottom/lower layer of starter shingles by cutting and applying a 13-3/4" x 20" piece at the lower left rake/eaves
corner overhanging rakes and eaves 1/4" to 3/4". Continue along the eaves with full-size 13-1/4" x 40" starter
shingles. Each top/upper starter course shingle shall have its 2" top section removed at the perforations,
resulting in 11-1/4" x 40" shingles. The colored granule portion of the "top" starter shingles shall be located
nearest the lowermost eave edge. Install the first top/upper starter shingle so that it is flush to the left side and
bottom edges of the first bottom/lower starter shingle. This first top/upper starter shingle shall be 11-1/4" x
38". Continue along the eaves with 11-1/4" x 40" top/upper starter shingles ensuring that the lower edges are
flush with the lower edges of the bottom/lower layer. Reference the product's wrapper for more specific
details.
Eaves: Fasten as shown below. Rakes: After applying the starter shingles at the eaves, but prior to installing
the field shingles, starter shingles may be applied up the slope at the rake edge. Fasten as shown below.
Fastening: Four nails are required per shingle. Nails shall be of sufficient length to penetrate into the deck 3/4"
or through the thickness of the decking, whichever is less. Nails are to be 11 or 12 gauge, corrosion -resistant
roofing nails with 3/8" heads.
Presidential Starter and Presidential IR Starter Shingles
1st Botkwn Staftr Full Bottom Starter
r—
t I
1st T e Starter
�•
6.6 UNIVERSAL STARTER:
6.6.1 General: While Universal Starter Strip shingles are specifically designed to be used with shingles 36" length and
having a weather exposure of < 5", they may be installed beneath shingles of any length if special precautions
are taken. IMPORTANT: In all cases the end joints of the starter and the first course shingles shall NEVER BE
LESS THAN 3-1/2" apart.
Eaves: The sealant on starter courses should face out and lie as close as possible to the eaves edge of the roof.
Fasten as described below. Rakes: After applying the starter shingles at the eaves, but prior to installing the
field shingles, starter shingles may be applied up the slope at the rake edge with sealant facing out and nearest
to the outer roof edge. Fasten as described below.
Fastening: Use four nails on these starter shingles as shown below. The sealant on starter courses shall lie as
close as possible to the eaves edge of the roof. Nails shall be of sufficient length to penetrate into the deck 3/4"
or through the thickness of the decking, whichever is less. Nails are to be 11 or 12 gauge, corrosion -resistant
roofing nails with 3/8" heads.
UNIVERSAL STARTER SHINGLES
3 6'
12" 12' I
NEMO ETC, LLC Evaluation Report 3532.09.05-1137
Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL5444-R16
CertainTeed Asphalt Roof Shingles Revision 17: 07/24/2020
Page 7 of 14
OMEMO I etc.
6.7 SWIFTSTART® STARTER SHINGLE:
Fastening: Use four nails, located as shown below
38-314" (984 mm)
l' (25 mm) from edge l' (25 mm) from edge I 7-5rfi'
(194 mm)
Max 3" r�
(76 mm)
The inner two fasteners must be placed such that they fag at least 3' (76 mm) from
the end joints of the shingle in the succeeding course.
6.8 CT 20T-' XTT- 25, XTT" 30 Ill
LOW AND STANDARD SLOPE
ENGLISH 12" 12" 12''
��(305 mm) (305 mm} (305 mm)�
-f-- 1_' —25 mm)—ialant 1"(25mm)
-�
5 §la" (145 mm)
5 r�z"for Norwood
Plant
METRIC 13t/a" 13r/s" 3rls"
1" (25 mm) Sealant 1" (25 mm)
6 UTs"
T
Figure 11-3: Use four nails for every full shingle.
STEEP SLOPE
Use four nails and six spots of asphalt roofing cement* for every full
shingle (Figure 11-4). Asphalt roofing cement meeting ASTM D4586
Type. II is suggested.
I•
Roofing Cement
Apply 1" (25 mm) spots of asphalt roofing cement
under each tab corner.
Figure 11-4: Use four mails and sic spots ofaspbatt cement on steep slopes.
*CAUTION: Excessive use of roofing cement can cause shingles
to blister.
Hip & Ridge: Cut Shingles
Note: The use of BASF 'Sonolostic° NP1T'" adhesive or Henkel VL ® Polyurethane Roof & Flashing Sealant" in accordance
with Certain Teed requirements is required for the ASTM D3161, Class F wind rating.
t �2'' (50 mm) Remove
(25 mm)� � _
i
li IF
l _ _ _12''
Cap Cap (305 mm)
Shingle Shingle 1
Figure 11-24: Cut tabs, then trim back to make crap shingles
(English dimensions shown).
NEMO ETC, LLC
Certificate of Authorization #32455
Tp" {305
(1251n) Sues
-�r�mas
p�1n
14� mm1 s oo� p�ar�l
Figure 11-25: Installation of caps along the hips and ridges.
7T" EDITION (2020) FBC NON-HVHZ EVALUATION
CertafnTeed Asphalt Roof Shingles
Evaluation Report 3532.09.05-R37
FL5444-R16
Revision 17: 07/24/2020
Page 8 of 14
6.9 ARCADIATM:
LOW AND STANDARD SLOPE STEEP SLOPE
Use SIX nails for every full shingle located as shown below.
Nail Line
Nail
Nail Line
1" (25 mm) 1' (25 mm) —
Figure 2: Use six nails for every full shingle.
Hip & Ridge: Cedar Crest' or Cedar Crest' IR
ON EMO I etc.
Use SIX nails and FOUR spots of asphalt roofing cement for every full
shingle as shown below. Apply asphalt roofing cement 1"(25 mm)
from edge of shingle. Asphalt roofing cement meeting ASTM D 4586
Type II is suggested.
Figure 3: Use six nails and four spots of asphalt
roofing cement on steep slopes.
Use two (2), minimum 1%-inch long fasteners per shingle. For the starter shingle, place fastener 1-inch from each side
edge and about 2-inch up from the starter shingle's exposed butt edge, ensuring minimum %-inch embedment into the
deck, or full penetration through the deck. For each full Cedar Crest shingle, place fasteners 8-5/8-inch up from its exposed
butt edge and 1-inch from each side edge.
Note: The use of BASF "Sonolastic° NP11" adhesive or Henkel "PLO Polyurethane Roof & Flashing Sealant" in accordance
with Certain Teed requirements is required for the ASTM D3161, Class F wind rating.
12'
3 mrn) (305 ff
,%,ura
QL�
m07
Hand -sealing adhesive
411
114"
314" —
�R
Dab of asphalt
cement between T„
shingle layers
NEMO ETC, LLC Evaluation Report 3532.09.05-1137
Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION F1.5444-1116
CertainTeed Asphalt Roof Shingles Revision 17: 07/24/2020
Page 9 of 14
OMEMO I etc.
6.10 BELMONT® OR BELMONT® IR:
Lowy and Standard Slope Steep Slope (greater than 21:12):
(2:12 to 21:12): Use SEVEN nails and EIGHT spots of
Use FIVE nails for every full Belmont shingle, asphalt rooting cement" for every full
located as shown below-
1 1 7' %mm}
or iZ
1� 1' (25 mmi
1' Z mm1-1
o Additional nails it required
}
_WP N
Belmont shingle. Apply asphalt roofing
cement 1" (25mm) from edge of shingle_
See below. Asphalt roofing cement meeting
ASTM D4586 Type 11 is suggested_
1 102' (38 mrp)
a* leiffl��
P
—1'(25rnm)
pz�
1'f25rrmj—1
min)
d 51d•
MCI mml
1'(25mmI Roofing Cement
Hip & Ridge:
Option 1: For Belmont°, refer to instructions for Cedar Crest® or Cedar Crest' IR.
For Belmont® IR, refer to instructions for Cedar Crest° IR.
Note: The use of BASF "Sonolastic° NP1`adhesive or Henkel "PL° Polyurethane Roof & Flashing Sealant"
in accordance with CertainTeed requirements is required for the ASTM D3161, Class F wind rating.
Option 2: For Belmont®: Shangle® Ridge
Note: The use of BASF "Sonolastic° NP1`adhesive or Henkel "PLI Polyurethane Roof & Flashing Sealant"
in accordance with CertainTeed requirements is required for the ASTM D3161, Class F wind rating.
Figure 17-18: Shangle° Ridge,
18 Exposure Remove tape
from the right side
and fasten
�ECotio
Faster theme
left[ side 85/8�/ RIGHT
FIRST j
LEFT
Figure 17-19:Installation ofSbangle° Ridge shingles
on hips and ridges.
NEMO ETC, LLC Evaluation Report 3532.09.05-1137
Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL5444-1116
CertainTeed Asphalt Roof Shingles Revision 17: 07/24/2020
Page 10 of 14
6.11 CARRIAGE HOUSE® AND GRAND MANOR®:
LOW AND STEEP SLOPE
STANDARD SLOPE
Use five nails for every full Shangle.
{16 mm)
+-1"
(25 mm)
8 �/s'1
(220 mm)
Figure 17-4: Use five nails for ever- fu11 Crand,flanor Shangle.
Carriage house Sbangle, or Centennial Slate.
Hip & Ridge: Refer to instructions for Shangle® Ridge.
OMEMO I etc.
Use seven nails and three spots of asphalt roofing cement for every
full Grand Manor Shangle. Use five nails and three spots of asphalt
roofing cement for even, full Carriage House Shangle and Centennial.
Slate. Apply asphalt roofing cement 1" (25 vim) from edge of shingle
(Figure 17-5). Asphalt roofing cement meeting ASTM D4586 Type 11
is suggested.
t (38 mm)
1�� o� less ;;
(25 mm)
5/8
(16 mmj
8 SC8"
(220 mm)
1'
(25 mm)
Booting Cement
Figure 17-5: When installing Grand ifanor Sbangles on steep slopes,
use seven nails and three spots of asphalt roofing cement.
6.12 LANDMARK®, LANDMARK° PRO, LANDMARK° PRO ARCHITECT 80, LANDMARK PRO SOLARIS®, LANDMARK® PREMIUM, LANDMARK
SOLARIs®, LANDMARK SOLARIS° IR, LANDMARK SOLARIS® GOLD/PLATINUM OR NORTHGATE®:
WIDE
NAILNG 12" 14 3A, i2'
AREA 1Y15mm) { '375mm) t (345mm)+�
T Ielirq Limts
u na
+1" {2c mml PPS ifs 1' (25mmj� �
l bwet nail iris
{ }
7 7 71
Naling areas for low and standard stapes (f om 2:12 M 21:12)
Nal oet4een upper 81awe- Les as s.�own above.
STEEP 12" 14-31X' 12"
SLOPE —(305 mm) —(375 mmj-- �-(305 min)--1
NAILING N2ilinq mits
AREA I 6siweah
�1'(25 mm) na+ Ilnes. I.,
{
17
.7
Roofing event
Nailing areas for steep slopes (greater than 21:12)
and "Storm -Nailing"
Nail between lower 2 nail lines as shown above.
NEMO ETC, LLC Evaluation Report 3532.09.05-1137
Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL5444-1116
CertainTeed Asphalt Roof Shingles Revision 17: 07/24/2020
Page 11 of 14
ON EMO I etc.
Hip & Ridge:
Option 1: Refer to instructions for Cedar Crest° or Cedar Crest® IR.
Option 2: NorthGate° Accessory or Shadow Ridge'
Note: The use of BASF "Sonolastic® NP1 "' adhesive or Henkel "PL ° Polyurethane Roof & Flashing
Sealant" in accordance with CertainTeed requirements is required for the ASTM D3161, Class F wind
rating. (Use of sealant is optional for Shadow Ridge® produced in Oxford, NO
9 2712T
- —cno mm}
415n 5, (125 rtirnl
13 114'
(337 Mrr.)
t
Ceptiadug Notch
Align these
notches to top
edge 01
Pcauiods Worm
NorthGate° Ridge
12"
(305mm)
6" 6"
(150mm) (150mm)
Notch for
Centering
12"
(305mm) Notches for Alignment to
the Top Edge of the Previous 7
Cap fors"(125mm)Exposure (1( m)
T
7518'
(194 inm)
English Dimension
Shadow Ridge®
1311811
(333 mm)—
f 6 5/8 ► f 6 518" ►
(1 88 mm1 068 mm)
Centering
13114" Notch e
(337 mm) � Align these"j
notches to top 7 5/8"
e(194 mrn)
dge of
previous course.
131/4"
(337mm)
NorthGate° Accessory
9718"
(250mm)
415MG 415/16"
(125mm) (125mm)
Metric Dimension
Shadow Ridge®
(305mm)
Laying Notch
I � III I
I I �
Figure 13-20: Use layingnotcbes to center shingles on hips and
ridges, and to locate the correct exposure.
7
75/8''
(196mm)
NEMO ETC, LLC Evaluation Report 3532.09.05-1137
Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL5444-1116
CertainTeed Asphalt Roof Shingles Revision 17: 07/24/2020
Page 12 of 14
6.13 LANDMARK® TL:
LANDMARK TL
LANDMARK TL
13112" 13" 131/2',
1—(343 mm)— -(330 mm)——(343 mm)—1
- tY �—V'(25rnm) 1'' (25 mm)FA R N F// 1/.
—
ftu e 134 Use fortr u(dlr for et,et)- fitll shiargle.
1"
(25 rr
ON EMO I etc.
Figure 13-5: Use six nails sand four spots of
asphalt roofing cement on steep slopes.
Hip & Ridge: Refer to instructions for Cedar Crest®, Cedar Crest® IR, NorthGate® Accessory or Shadow Ridge®.
6.14 PRESIDENTIAL SHAKE®, PRESIDENTIAL SHAKE® IR, PRESIDENTIAL SHAKE® TL, PRESIDENTIAL SOLARIS°:
LOW AND STANDARD SLOPE: STEEP SLOPE:
For low and standard slopes, use five nails for each full Presidential For steep slopes, use nine nails for each full Presidential shingle and
shingle as shown below. apply 1" diameter spots of asphalt roofing cement under each shingle tab.
After applying 5 nails in between the nailing guide lines, apply 4 nails 1"
Nailing 40'' above tab cutouts malting certain tabs of overlying shingle cover nails.
Guide Lines (1016 mm)
5 114"
(133 mm) � 14 1l4''
t-1112" 31mm) (362mm)
— — — - — — — —•— — — — - 1
NOTE: Apply nails on painted guideline.
Figure 16-6. Fastening Presidenhat and Presidentwl TL Shake 1" diameter asphalt roofing cement
shingles on low and standard slopes.
Figure 16-7 Fastening Presidential and Presidential T/L Shake
shingles on steep slopes.
Hip & Ridge: Refer to instructions for Cedar Crest® or Cedar Crest® IR.
NEMO ETC, LLC Evaluation Report 3532.09.05-1137
Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL5444-R16
CertainTeed Asphalt Roof Shingles Revision 17: 07/24/2020
Page 13 of 14
6.15 HIGHLAND SLATE®:
LOW AND STANDARD SLOPE:
1230 mm}
(230 mm]
l� mm]
(234 mm)
(25 mm)
(25 mm)
9-3f8"
(240 mm)
Miami -Dad e requ fires
SIX nails (two nails
1" (25 mm)
Installed over center
cutout as shown).
Figure 11-3: Use FIVE nails for eve, y Highland Slate shingle.
ON EMO I etc.
STEEP SLOPE:
Use FIVE nails and EIGHT spots of asphalt roofing cement* for each
full Highland Slate shingle. For Miami -Dade, SIXnailsare required.
Apply 1" diameter spots of asphaltroofing cement under each tab
corner. Asphalt roofing cement meeting ASTM D4586 'Igpe IL is suggested.
Miami -Dade requires
SIX nails (two nails
installed over center
cutout as shown ).
Figure 113A: Use IT E nails and eight spots of asphalt
roofing cement under each tab corner.
*CAUTION: Excessive use of roofing cement can cause shingles
to blister.
Hip & Ridge: Refer to instructions for Cedar Crest®, Cedar Crest® IR or Shangle Ridge®.
6.16 PATRIOT:
LOW AND STANDARD SLOPE STEEP SLOPE
Use FOUR nails for every fttll shingle located as shown below.
O lant
G118' �1 I25 Mfn)
(156MM) J J
i333^11'!j i333mm
Use FOUR nails and four spots of asphalt roofing cement for every full
shingle as shown below. Asphalt roofing cement meeting ASTM D4586
Type II is suggested. Apply 1"(25 inm) spots of asphall roofing
cement as shown.
CAUTION: Excessive use of roofing cement can cause shingles to blister.
-------------
(85mm) 25 mmt —
{156mmj I�
TT_ fRooling Cement
12-1J8' +I_ 13-1,B. _+_ 12.116
MIMM) (333mm) 1333")
Hip & Ridge: Refer to instructions for Cedar Crest°, Cedar Crest® IR, NorthGate° Accessory, Shadow Ridge° or Shangle
Ridge°.
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
UL LLC—QUA9625; (414) 248-6409; karen.buchmann@us.ul.com
- END OF EVALUATION REPORT -
NEMO ETC, LLC Evaluation Report 3532.09.05-1117
Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL5444-R16
CertainTeed Asphalt Roof Shingles Revision 17: 07/24/2020
Page 14 of 14