Loading...
HomeMy WebLinkAboutCT Shingle NOANEMO I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 to (203) 262-9245 ENGINEER EVALUATE TEST CONSULT REPORTEVALUATION CertainTeed, LLC Evaluation Report 3532.09.05-R17 20 Moores Road FL5444-R16 Malvern, PA 19355 Date of Issuance: 09/22/2005 (610) 893-5400 Revision 17: 07/24/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 7t' Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: CertainTeed Asphalt Roof Shingles. LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1 / R905.2.6.1 CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEW ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOletc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 14. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 07/24/2020. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 02018 NEMO ETC, LLC ON EMO I etc. TABLE 1: ASPHALT SHINGLE COMPONENTS Type Product Description Material Standard Plant(s) Fiberglass reinforced starter shingle, High -Performance Starter measuring 10" x 36", for use with ASTM D3462 NC Grand Manor' and Highland Slate° Fiberglass reinforced starter shingle, measuring 13-1/4" x 40", with a Presidential® Starter reinforcement on the underside, for ASTM D3462 CA(F) use with Presidential Shake' and Presidential Shake® TL Starter Strips Presidential® Starter IR Fiberglass reinforced starter shingle, measuring 13-1/4" x 40", for use with ASTM D3462 CA(F) Presidential Shake® IR SwiftStart® Starter Shingle Fiberglass reinforced starter strip, measuring 15-1/4" x 38-3/4" ASTM D3462 MN Fiberglass reinforced starter shingle, Universal Starter measuring 7" x 36", for use with shingles measuring 12" x 36" having a ASTM D3462 NC weather exposure < 5" CT 20'" LA, NC CT 20'" Metric OR Fiberglass reinforced, 3-tab asphalt roof shingle ASTM D3462 XT' 25 LA, MN, NC, OH XT' 25 Metric OH, OR XT'"" 30 IR LA Highland Slate° Fiberglass reinforced, 4-tab asphalt roof shingle ASTM D3462 NC Arcadia'" CA(F) Belmont® NC Belmont® IR NC Carriage House" NC Grand Manor' NC Landmark® CA(W), GA, LA, MA, MO, MN, NC, OH, OR, TX Landmark" Pro CA(W), GA, MA, MO, MN, OH, NC Asphalt Fiberglass reinforced, laminated asphalt roof shingle ASTM D3462 Landmark' Pro Architect 80 OR Shingles Landmark Pro Solaris° CA(W) Landmark® Premium CA(W), MA, MN, OR, NC Landmark Solaris° CA(W), OR Landmark Solaris° Gold/Platinum OR Landmark® TL CA(F) Landmark® TL Solaris CA(F) NorthGate® Fiberglass reinforced, laminated, SBS modified bitumen roof shingle ASTM D3462 MN, OR Presidential Shake° CA(F), MN Presidential Shake' IR MN Fiberglass reinforced, architectural asphalt roof shingle ASTM D3462 Presidential Shake' TL CA(F), MN Presidential Solaris° CA(F) Presidential TL Solaris CA(F) Patriot Fiberglass reinforced asphalt roof strip -shingle; laminated appearance ASTM D3462 OH, OR Note: Any of the above listed shingles may be produced in AR (algae resistant) versions NEMO ETC, LLC Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION CertainTeed Asphalt Roof Shingles Evaluation Report 3532.09.05-R37 FL5444-R16 Revision 17: 07/24/2020 Page 3 of 14 ONEMO I etc. TABLE 1 (CONTINUED): ASPHALT SHINGLE COMPONENTS Type Product Description Material Standard Plant(s) Hip & Ridge Shingles Shangle Ridge° Fiberglass reinforced accessory shingles for hip and ridge installation ASTM D3462 NC Shadow Ridge° ASTM D3462 MA, MN, NC, OH Shadow Ridge° Metric ASTM D3462 OR Cedar Crest® None NC Cedar Crest® IR None NC NorthGate® Ridge ASTM D3462 OR NorthGate® Accessory ASTM D3462 MN 5.1 This is a Building Code Evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami - Dade Counties). 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 Wind Classification: Refer to Section 6 for installation requirements to meet wind classifications. TABLE 2A: WIND CLASSIFICATIONS, ASPHALT SHINGLES Product FBC Table 1507.2.7.1 or R905.2.6.1 CT 20TI ASTM D3161(F) & ASTM D7158(H) CT 20T" Metric ASTM D3161(F) & ASTM D7158(H) XT'^" 25 ASTM D3161(F) & ASTM D7158(H) XT"" 25 Metric ASTM D3161(F) & ASTM D7158(H) XT"" 30 IR ASTM D3161(F) & ASTM D7158(H) Arcadia" ASTM D3161(F) & ASTM D7158(H) Belmont® ASTM D3161(F) & ASTM D7158(H) Belmont® IR ASTM D3161(F) & ASTM D7158(H) Carriage House° ASTM D3161(F) & ASTM D7158(H) Grand Manor® ASTM D3161(F) & ASTM D7158(H) Landmark' ASTM D3161(F) & ASTM D7158(H) Landmark® Pro ASTM D3161(F) & ASTM D7158(H) Landmark' Pro Architect 80 ASTM D3161(F) & ASTM D7158(H) Landmark Pro Solaris® ASTM D3161(F) & ASTM D7158(H) Landmark® Premium ASTM D3161(F) & ASTM D7158(H) Landmark Solaris° ASTM D3161(F) & ASTM D7158(H) Landmark Solaris° Gold/Platinum ASTM D3161(F) & ASTM D7158(H) Landmark° TL ASTM D3161(F) & ASTM D7158(H) NorthGate° ASTM D3161(F) & ASTM D7158(H) Presidential Shake' ASTM D3161(F) & ASTM D7158(H) Presidential Shake° IR ASTM D3161(F) & ASTM D7158(H) NEMO ETC, LLC Evaluation Report 3532.09.05-R37 Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL5444-1116 CertainTeed Asphalt Roof Shingles Revision 17: 07/24/2020 Page 4 of 14 5.5.1 5.5.2 5.5.3 5.5.4 5.5.5 OMEMO I etc. TABLE 2A: WIND CLASSIFICATIONS, ASPHALT SHINGLES Product FBC Table 1507.2.7.1 or R905.2.6.1 Presidential Shake° TL ASTM D3161(F) & ASTM D7158(H) Presidential Solaris® ASTM D3161(F) & ASTM D7158(H) Presidential TL Solaris ASTM D3161(F) & ASTM D7158(H) Highland Slate° ASTM D3161(F) & ASTM D7158(H) Patriot ASTM D3161(F) & ASTM D7158(H) Classification by ASTM D7158: ASTM D7158, Class H applies only to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. Analysis in accordance with ASTM D7158 indicates the measured uplift resistance (RT or RA) for the CertainTeed asphalt Roof shingles listed in Table 1 (except Presidential Solaris°, Landmark Pro Solaris° and Landmark Solaris° Gold/Platinum) exceeds the calculated uplift force (FT) under the following conditions: • maximum design wind speed of Vasd = 150 mph (VUit = 194 mph) located in Exposure D conditions no topographical variations (flat terrain) • having a mean roof height less than or equal to 60 feet. The shingles (except Presidential Solaris°, Landmark Pro Solaris° and Landmark Solaris® Gold/Platinum) are permissible under Code for installation in these conditions using the installation procedures detailed in this Evaluation Report and CertainTeed minimum requirements, subject to minimum codified fastening requirements established within any local jurisdiction, which shall take precedence. TABLE 213: WIND CLASSIFICATIONS, STARTER STRIPS AND HIP & RIDGE Type Product FBC Table 1507.2.7.1 or R905.2.6.1 High -Performance Starter ASTM D3161, Class F Presidential° Starter ASTM D3161, Class F Starter Strips Presidential° Starter IR ASTM D3161, Class F SwiftStart® Starter Shingle ASTM D3161, Class F Universal Starter ASTM D3161, Class F Shangle Ridge® ASTM D3161, Class F (sealant required, See Section 6) Shadow Ridge® (NCproduction) ASTM D3161, Class F Shadow Ridge° (MA, MN or OH production) ASTM D3161, Class F (sealant required, See Section 6) Hip & Ridge Shadow Ridge ® Metric (OR production) ASTM D3161, Class F (sealant required, See Section 6) Shingles Cedar Crest' ASTM D3161, Class F (sealant required, See Section 6) Cedar Crest° IR ASTM D3161, Class F (sealant required, See Section 6) NorthGate® Ridge ASTM D3161, Class F NorthGate® Accessory ASTM D3161, Class F High -Performance Starter shingles are limited to use with Grand Manor® and Highland Slate® shingles. Presidential® Starter shingles must be applied using two (2) overlapping layers and are limited to use with Presidential Shake® and Presidential Shake® TL shingles. Presidential® Starter IR shingles must be applied using two (2) overlapping layers and are limited to use with Presidential Shake® IR shingles. Universal Starter shingles are limited to use with CertainTeed shingles measuring 12" x 36" having a weather exposure < 5". NEMO ETC, LLC Evaluation Report 3532.09.05-1137 Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL5444-R16 CertainTeed Asphalt Roof Shingles Revision 17: 07/24/2020 Page 5 of 14 OMEMO I etc. 5.6 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. Refer to the Product Approval of the component manufacturer for components that are produced by a Product Manufacturer other than the report holder on Page 1 of this Evaluation Report. 6.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle manufacturer's minimum requirements. 6.1.1 Underlayment shall be acceptable to CertainTeed, LLC and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Installation of asphalt shingles shall comply with the CertainTeed, LLC current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or Section R905.2.6 and the minimum requirements herein. 6.2.1 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.2 Where the roof slope exceeds 21 units vertical in 12 units horizontal, use the "Steep Slope" directions. 6.3 CertainTeed asphalt shingles are acceptable for use in reroof (tear -off) or recover applications, subject to the limitations set forth in FBC Section 1511 or R908 and CertainTeed published installation instructions. 6.4 HIGH-PERFORMANCE STARTER: 6.4.1 Eaves: For the first starter shingle in each roof corner, use five (5) nails as shown below. All other starter shingles require four (4) nails per shingle. Nails must be of sufficient length to penetrate into the deck 3/4" or through the thickness of the decking, whichever is less. Nails are to be 11 or 12 gauge, corrosion -resistant roofing nails with 3/8" heads. Apply the 10" starter shingle with its factory -applied sealant stripes at the shingle's lower -most edge and nail firmly into the roof deck as near as possible *(maximum 3") to the eaves edge while avoiding the sealant. With the starter shingle well fastened to the deck and the sealant low on the starter shingle, it can firmly adhere to the first course shingles. *If nailing within 3" is not possible, nail as closely as possible, then lift and adhere the starter shingle to the underlayment and to the supporting structure with CertainTeed FlintBondl" Asphalt Roofing Cement -Caulk Grade, or approved equal. Rakes: Prior to installation of the field shingles, starter shingles may be applied up the slope along the rake edge with sealant edge placed closest to the rake edge. Fasten as indicated below. HIGH-PERFORMANCE STARTER SHINGLES 36 1 316" (Max T ) NEMO ETC, LLC Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION CertainTeed Asphalt Roof Shingles Evaluation Report 3532.09.05-R17 FL5444-R16 Revision 17: 07/24/2020 Page 6 of 14 ON EMO I etc. 6.5 PRESIDENTIAL® STARTER AND PRESIDENTIAL® STARTER IR: 6.5.1 General: These shingles shall be applied by using two (2) overlapping layers. Begin application of the bottom/lower layer of starter shingles by cutting and applying a 13-3/4" x 20" piece at the lower left rake/eaves corner overhanging rakes and eaves 1/4" to 3/4". Continue along the eaves with full-size 13-1/4" x 40" starter shingles. Each top/upper starter course shingle shall have its 2" top section removed at the perforations, resulting in 11-1/4" x 40" shingles. The colored granule portion of the "top" starter shingles shall be located nearest the lowermost eave edge. Install the first top/upper starter shingle so that it is flush to the left side and bottom edges of the first bottom/lower starter shingle. This first top/upper starter shingle shall be 11-1/4" x 38". Continue along the eaves with 11-1/4" x 40" top/upper starter shingles ensuring that the lower edges are flush with the lower edges of the bottom/lower layer. Reference the product's wrapper for more specific details. Eaves: Fasten as shown below. Rakes: After applying the starter shingles at the eaves, but prior to installing the field shingles, starter shingles may be applied up the slope at the rake edge. Fasten as shown below. Fastening: Four nails are required per shingle. Nails shall be of sufficient length to penetrate into the deck 3/4" or through the thickness of the decking, whichever is less. Nails are to be 11 or 12 gauge, corrosion -resistant roofing nails with 3/8" heads. Presidential Starter and Presidential IR Starter Shingles 1st Botkwn Staftr Full Bottom Starter r— t I 1st T e Starter �• 6.6 UNIVERSAL STARTER: 6.6.1 General: While Universal Starter Strip shingles are specifically designed to be used with shingles 36" length and having a weather exposure of < 5", they may be installed beneath shingles of any length if special precautions are taken. IMPORTANT: In all cases the end joints of the starter and the first course shingles shall NEVER BE LESS THAN 3-1/2" apart. Eaves: The sealant on starter courses should face out and lie as close as possible to the eaves edge of the roof. Fasten as described below. Rakes: After applying the starter shingles at the eaves, but prior to installing the field shingles, starter shingles may be applied up the slope at the rake edge with sealant facing out and nearest to the outer roof edge. Fasten as described below. Fastening: Use four nails on these starter shingles as shown below. The sealant on starter courses shall lie as close as possible to the eaves edge of the roof. Nails shall be of sufficient length to penetrate into the deck 3/4" or through the thickness of the decking, whichever is less. Nails are to be 11 or 12 gauge, corrosion -resistant roofing nails with 3/8" heads. UNIVERSAL STARTER SHINGLES 3 6' 12" 12' I NEMO ETC, LLC Evaluation Report 3532.09.05-1137 Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL5444-R16 CertainTeed Asphalt Roof Shingles Revision 17: 07/24/2020 Page 7 of 14 OMEMO I etc. 6.7 SWIFTSTART® STARTER SHINGLE: Fastening: Use four nails, located as shown below 38-314" (984 mm) l' (25 mm) from edge l' (25 mm) from edge I 7-5rfi' (194 mm) Max 3" r� (76 mm) The inner two fasteners must be placed such that they fag at least 3' (76 mm) from the end joints of the shingle in the succeeding course. 6.8 CT 20T-' XTT- 25, XTT" 30 Ill LOW AND STANDARD SLOPE ENGLISH 12" 12" 12'' ��(305 mm) (305 mm} (305 mm)� -f-- 1_' —25 mm)—ialant 1"(25mm) -� 5 §la" (145 mm) 5 r�z"for Norwood Plant METRIC 13t/a" 13r/s" 3rls" 1" (25 mm) Sealant 1" (25 mm) 6 UTs" T Figure 11-3: Use four nails for every full shingle. STEEP SLOPE Use four nails and six spots of asphalt roofing cement* for every full shingle (Figure 11-4). Asphalt roofing cement meeting ASTM D4586 Type. II is suggested. I• Roofing Cement Apply 1" (25 mm) spots of asphalt roofing cement under each tab corner. Figure 11-4: Use four mails and sic spots ofaspbatt cement on steep slopes. *CAUTION: Excessive use of roofing cement can cause shingles to blister. Hip & Ridge: Cut Shingles Note: The use of BASF 'Sonolostic° NP1T'" adhesive or Henkel VL ® Polyurethane Roof & Flashing Sealant" in accordance with Certain Teed requirements is required for the ASTM D3161, Class F wind rating. t �2'' (50 mm) Remove (25 mm)� � _ i li IF l _ _ _12'' Cap Cap (305 mm) Shingle Shingle 1 Figure 11-24: Cut tabs, then trim back to make crap shingles (English dimensions shown). NEMO ETC, LLC Certificate of Authorization #32455 Tp" {305 (1251n) Sues -�r�mas p�1n 14� mm1 s oo� p�ar�l Figure 11-25: Installation of caps along the hips and ridges. 7T" EDITION (2020) FBC NON-HVHZ EVALUATION CertafnTeed Asphalt Roof Shingles Evaluation Report 3532.09.05-R37 FL5444-R16 Revision 17: 07/24/2020 Page 8 of 14 6.9 ARCADIATM: LOW AND STANDARD SLOPE STEEP SLOPE Use SIX nails for every full shingle located as shown below. Nail Line Nail Nail Line 1" (25 mm) 1' (25 mm) — Figure 2: Use six nails for every full shingle. Hip & Ridge: Cedar Crest' or Cedar Crest' IR ON EMO I etc. Use SIX nails and FOUR spots of asphalt roofing cement for every full shingle as shown below. Apply asphalt roofing cement 1"(25 mm) from edge of shingle. Asphalt roofing cement meeting ASTM D 4586 Type II is suggested. Figure 3: Use six nails and four spots of asphalt roofing cement on steep slopes. Use two (2), minimum 1%-inch long fasteners per shingle. For the starter shingle, place fastener 1-inch from each side edge and about 2-inch up from the starter shingle's exposed butt edge, ensuring minimum %-inch embedment into the deck, or full penetration through the deck. For each full Cedar Crest shingle, place fasteners 8-5/8-inch up from its exposed butt edge and 1-inch from each side edge. Note: The use of BASF "Sonolastic° NP11" adhesive or Henkel "PLO Polyurethane Roof & Flashing Sealant" in accordance with Certain Teed requirements is required for the ASTM D3161, Class F wind rating. 12' 3 mrn) (305 ff ,%,ura QL� m07 Hand -sealing adhesive 411 114" 314" — �R Dab of asphalt cement between T„ shingle layers NEMO ETC, LLC Evaluation Report 3532.09.05-1137 Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION F1.5444-1116 CertainTeed Asphalt Roof Shingles Revision 17: 07/24/2020 Page 9 of 14 OMEMO I etc. 6.10 BELMONT® OR BELMONT® IR: Lowy and Standard Slope Steep Slope (greater than 21:12): (2:12 to 21:12): Use SEVEN nails and EIGHT spots of Use FIVE nails for every full Belmont shingle, asphalt rooting cement" for every full located as shown below- 1 1 7' %mm} or iZ 1� 1' (25 mmi 1' Z mm1-1 o Additional nails it required } _WP N Belmont shingle. Apply asphalt roofing cement 1" (25mm) from edge of shingle_ See below. Asphalt roofing cement meeting ASTM D4586 Type 11 is suggested_ 1 102' (38 mrp) a* leiffl�� P —1'(25rnm) pz� 1'f25rrmj—1 min) d 51d• MCI mml 1'(25mmI Roofing Cement Hip & Ridge: Option 1: For Belmont°, refer to instructions for Cedar Crest® or Cedar Crest' IR. For Belmont® IR, refer to instructions for Cedar Crest° IR. Note: The use of BASF "Sonolastic° NP1`adhesive or Henkel "PL° Polyurethane Roof & Flashing Sealant" in accordance with CertainTeed requirements is required for the ASTM D3161, Class F wind rating. Option 2: For Belmont®: Shangle® Ridge Note: The use of BASF "Sonolastic° NP1`adhesive or Henkel "PLI Polyurethane Roof & Flashing Sealant" in accordance with CertainTeed requirements is required for the ASTM D3161, Class F wind rating. Figure 17-18: Shangle° Ridge, 18 Exposure Remove tape from the right side and fasten �ECotio Faster theme left[ side 85/8�/ RIGHT FIRST j LEFT Figure 17-19:Installation ofSbangle° Ridge shingles on hips and ridges. NEMO ETC, LLC Evaluation Report 3532.09.05-1137 Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL5444-1116 CertainTeed Asphalt Roof Shingles Revision 17: 07/24/2020 Page 10 of 14 6.11 CARRIAGE HOUSE® AND GRAND MANOR®: LOW AND STEEP SLOPE STANDARD SLOPE Use five nails for every full Shangle. {16 mm) +-1" (25 mm) 8 �/s'1 (220 mm) Figure 17-4: Use five nails for ever- fu11 Crand,flanor Shangle. Carriage house Sbangle, or Centennial Slate. Hip & Ridge: Refer to instructions for Shangle® Ridge. OMEMO I etc. Use seven nails and three spots of asphalt roofing cement for every full Grand Manor Shangle. Use five nails and three spots of asphalt roofing cement for even, full Carriage House Shangle and Centennial. Slate. Apply asphalt roofing cement 1" (25 vim) from edge of shingle (Figure 17-5). Asphalt roofing cement meeting ASTM D4586 Type 11 is suggested. t (38 mm) 1�� o� less ;; (25 mm) 5/8 (16 mmj 8 SC8" (220 mm) 1' (25 mm) Booting Cement Figure 17-5: When installing Grand ifanor Sbangles on steep slopes, use seven nails and three spots of asphalt roofing cement. 6.12 LANDMARK®, LANDMARK° PRO, LANDMARK° PRO ARCHITECT 80, LANDMARK PRO SOLARIS®, LANDMARK® PREMIUM, LANDMARK SOLARIs®, LANDMARK SOLARIS° IR, LANDMARK SOLARIS® GOLD/PLATINUM OR NORTHGATE®: WIDE NAILNG 12" 14 3A, i2' AREA 1Y15mm) { '375mm) t (345mm)+� T Ielirq Limts u na +1" {2c mml PPS ifs 1' (25mmj� � l bwet nail iris { } 7 7 71 Naling areas for low and standard stapes (f om 2:12 M 21:12) Nal oet4een upper 81awe- Les as s.�own above. STEEP 12" 14-31X' 12" SLOPE —(305 mm) —(375 mmj-- �-(305 min)--1 NAILING N2ilinq mits AREA I 6siweah �1'(25 mm) na+ Ilnes. I., { 17 .7 Roofing event Nailing areas for steep slopes (greater than 21:12) and "Storm -Nailing" Nail between lower 2 nail lines as shown above. NEMO ETC, LLC Evaluation Report 3532.09.05-1137 Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL5444-1116 CertainTeed Asphalt Roof Shingles Revision 17: 07/24/2020 Page 11 of 14 ON EMO I etc. Hip & Ridge: Option 1: Refer to instructions for Cedar Crest° or Cedar Crest® IR. Option 2: NorthGate° Accessory or Shadow Ridge' Note: The use of BASF "Sonolastic® NP1 "' adhesive or Henkel "PL ° Polyurethane Roof & Flashing Sealant" in accordance with CertainTeed requirements is required for the ASTM D3161, Class F wind rating. (Use of sealant is optional for Shadow Ridge® produced in Oxford, NO 9 2712T - —cno mm} 415n 5, (125 rtirnl 13 114' (337 Mrr.) t Ceptiadug Notch Align these notches to top edge 01 Pcauiods Worm NorthGate° Ridge 12" (305mm) 6" 6" (150mm) (150mm) Notch for Centering 12" (305mm) Notches for Alignment to the Top Edge of the Previous 7 Cap fors"(125mm)Exposure (1( m) T 7518' (194 inm) English Dimension Shadow Ridge® 1311811 (333 mm)— f 6 5/8 ► f 6 518" ► (1 88 mm1 068 mm) Centering 13114" Notch e (337 mm) � Align these"j notches to top 7 5/8" e(194 mrn) dge of previous course. 131/4" (337mm) NorthGate° Accessory 9718" (250mm) 415MG 415/16" (125mm) (125mm) Metric Dimension Shadow Ridge® (305mm) Laying Notch I � III I I I � Figure 13-20: Use layingnotcbes to center shingles on hips and ridges, and to locate the correct exposure. 7 75/8'' (196mm) NEMO ETC, LLC Evaluation Report 3532.09.05-1137 Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL5444-1116 CertainTeed Asphalt Roof Shingles Revision 17: 07/24/2020 Page 12 of 14 6.13 LANDMARK® TL: LANDMARK TL LANDMARK TL 13112" 13" 131/2', 1—(343 mm)— -(330 mm)——(343 mm)—1 - tY �—V'(25rnm) 1'' (25 mm)FA R N F// 1/. — ftu e 134 Use fortr u(dlr for et,et)- fitll shiargle. 1" (25 rr ON EMO I etc. Figure 13-5: Use six nails sand four spots of asphalt roofing cement on steep slopes. Hip & Ridge: Refer to instructions for Cedar Crest®, Cedar Crest® IR, NorthGate® Accessory or Shadow Ridge®. 6.14 PRESIDENTIAL SHAKE®, PRESIDENTIAL SHAKE® IR, PRESIDENTIAL SHAKE® TL, PRESIDENTIAL SOLARIS°: LOW AND STANDARD SLOPE: STEEP SLOPE: For low and standard slopes, use five nails for each full Presidential For steep slopes, use nine nails for each full Presidential shingle and shingle as shown below. apply 1" diameter spots of asphalt roofing cement under each shingle tab. After applying 5 nails in between the nailing guide lines, apply 4 nails 1" Nailing 40'' above tab cutouts malting certain tabs of overlying shingle cover nails. Guide Lines (1016 mm) 5 114" (133 mm) � 14 1l4'' t-1112" 31mm) (362mm) — — — - — — — —•— — — — - 1 NOTE: Apply nails on painted guideline. Figure 16-6. Fastening Presidenhat and Presidentwl TL Shake 1" diameter asphalt roofing cement shingles on low and standard slopes. Figure 16-7 Fastening Presidential and Presidential T/L Shake shingles on steep slopes. Hip & Ridge: Refer to instructions for Cedar Crest® or Cedar Crest® IR. NEMO ETC, LLC Evaluation Report 3532.09.05-1137 Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL5444-R16 CertainTeed Asphalt Roof Shingles Revision 17: 07/24/2020 Page 13 of 14 6.15 HIGHLAND SLATE®: LOW AND STANDARD SLOPE: 1230 mm} (230 mm] l� mm] (234 mm) (25 mm) (25 mm) 9-3f8" (240 mm) Miami -Dad e requ fires SIX nails (two nails 1" (25 mm) Installed over center cutout as shown). Figure 11-3: Use FIVE nails for eve, y Highland Slate shingle. ON EMO I etc. STEEP SLOPE: Use FIVE nails and EIGHT spots of asphalt roofing cement* for each full Highland Slate shingle. For Miami -Dade, SIXnailsare required. Apply 1" diameter spots of asphaltroofing cement under each tab corner. Asphalt roofing cement meeting ASTM D4586 'Igpe IL is suggested. Miami -Dade requires SIX nails (two nails installed over center cutout as shown ). Figure 113A: Use IT E nails and eight spots of asphalt roofing cement under each tab corner. *CAUTION: Excessive use of roofing cement can cause shingles to blister. Hip & Ridge: Refer to instructions for Cedar Crest®, Cedar Crest® IR or Shangle Ridge®. 6.16 PATRIOT: LOW AND STANDARD SLOPE STEEP SLOPE Use FOUR nails for every fttll shingle located as shown below. O lant G118' �1 I25 Mfn) (156MM) J J i333^11'!j i333mm Use FOUR nails and four spots of asphalt roofing cement for every full shingle as shown below. Asphalt roofing cement meeting ASTM D4586 Type II is suggested. Apply 1"(25 inm) spots of asphall roofing cement as shown. CAUTION: Excessive use of roofing cement can cause shingles to blister. ------------- (85mm) 25 mmt — {156mmj I� TT_ fRooling Cement 12-1J8' +I_ 13-1,B. _+_ 12.116 MIMM) (333mm) 1333") Hip & Ridge: Refer to instructions for Cedar Crest°, Cedar Crest® IR, NorthGate° Accessory, Shadow Ridge° or Shangle Ridge°. As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. UL LLC—QUA9625; (414) 248-6409; karen.buchmann@us.ul.com - END OF EVALUATION REPORT - NEMO ETC, LLC Evaluation Report 3532.09.05-1117 Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL5444-R16 CertainTeed Asphalt Roof Shingles Revision 17: 07/24/2020 Page 14 of 14