Loading...
HomeMy WebLinkAboutRevisions, Added Modified Bituman OFFICE USE ONLY: 7 ` DATE FILED: ��` V` PERNUT# REVISION FEE: \n 7 RECEIPT# PLANNING&DEVELOPMENT SERVICES p ,• ;: BUILDING&CODE REGULATION DIVISION ; 2300 VIRGINIA AVENUE FORT PIERCE,FL 34982.56 (772)462.1553 APPLICATION FOR BUILDING PERMIT RE PROJECT INFORMATION LOCATION/SITE ADDRESS- 6� IV DETAILED DESCRIPTION OF PROJECT REVISIONS: CONTRACTOR INFORMATION: to STATE STATE of FL REG./CERT. #: Cc j VST.LUCIE CO CERT. #: BUSINESS NAME: sit,vA ,� QUALIFIERS NAME: ADDRESS: 6 CITY: r STATE: 7/ ZIP: yllVF PHONE(DAYTIME): )'-t'j Z--C(C$_C)�z n FAX: 72 7��LX- r)2°`( - OWNER/BUILDER INFORMATION: NAME: . ADDRESS: ' CITY: j' . ,n�e STATE: ZIP: PHONE(DAYTIME: FAX: ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: STATE: ZIP: PHONE(DAYTRAE): FAX: SLCCC: 9123109 file Copy Revised 06130117 /� /� �1 , .4 _ ,�i. �• ` �i f'� i i� / ' j - S , LLCf,L �.. hST c s.s ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code-Building INSTRUCTION PAGE " COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Required Sections of Attachments Required Roof System the Permit Application See List Below Form Low Slope Application A,B,C 1,2,3,4,5,6,7 Prescriptive BUR-RAS 150 A,B,C 2,4,5,6,7 Asphaltic Shingles A,B,D 1,2,4,5,6,7 Concrete or Clay Tile A,B,D,E 1,2,3,4,5,6,7 Metal Roofs A,B,D 1,2,3,4,5,6,7- Wood Shingles and A,B,D 1,2,4,5,6,7 Shakes Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16,or if applicable,RAS 127 or RAS 128 4. Other Component of Product Approval S. Municipal Permit Application 6. Owners Notification for Roofing Considerations(Reroofing Only) L�� 7. Any Required Roof Testing/Calculation Documentation iie Copy Form RooflnfoFeb21 Rev Feb 18,2021 I i � T L v_ Section A(General Information) •L Master Permit No. — � Process No. Contractors Name:� ��'`����� License# CCU (off Job Address Q-A kQ ROOF CATEGORY w Slope ❑Mechanically Fastened Tile ❑Mortar/Adhesive Set Tiles ❑Asphaltic Shingles ❑Metal Panel/Shingles ❑Wood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE ❑ New roof ❑ Repair ❑ Maintenance ❑ Reroofing ❑Recovering .ROOF SYSTEM INFORMATION Low Slope Roof Area(SF) Steep Sloped Roof Area(SF) 5-4)' Total(SF) Section B(Roof Plan) Sketch Roof Plan: Illustrate all levels and.sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels,clearly identify dimensions of elevated pressure zones and location of parapets. � I I i. Section C(Low Slope Roof) Surfacing: — �- Fill in specific roof assembly components and identify Fastener Spacing for Anchor/Base Sheet A meet: manufacturer Zone 1':_....."oc @ Lap,#Rows_® "Go ' (If a component is not used,identify as"NA") Zone 1:r"oc @ Lap,#Rows ®moo System Manufacturer: C c� ..� Zone 2' "oc @ Lap,#Rows ®— moo Zone 3• "oc @ Lap,#Rows—® coo Product Approval No.: Number of Fasteners Per Insulation Board: Design Wind Pressures,From RAS 128 Or Calculations: Zone 1'' Zone 1: Zone 2: Zone 3- Zone Vfk, Zone 1i 34,1 Zone 2: Zone 3a�W, Illustrate Components Noted and Details as Applicable: Max. Design Pressure,from the specific product approval Woodblocking, Gutter, Edge Termination, Stripping, system: l— /� ZO,�` Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing,Coping,Etc., Deck: dB / Indicate: Mean Roof Height, Parapet Height, Height of Base Type: 7-543 Z F? "-)00 c'�.�i' -Flashing,Component Material,Material'Thickness,Fastener Type,Fastener Spacing or Submit Manufacturers Details that Gauge Thickness: Comply with RAS 111 and Chapter 16.. Slope: !2s Anchor/Base Sheet&No.df Ply(s): Anchor/Base Sheet Fastener/Bonding Material: 0n4' 0rLA Insulation Base Layer" Base Insultation Size and Thickness: Parapet Base Insulation Fastener/Bonding Material: Height K!A- Top Insulation Layer:_ Top Insulation Size and Thickness: 4 OQ FT. Top Insulation Fastener/Bonding Material: f Mean Base Sheet(s)&No.of Ply(s): Roof Base Sheet Fastener/Bonding Material: Height Ply Sheet(s)'&No.of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply:GT� Top Ply Fastener/Bonding Material: Section D(Steep Slope Roof System) Roof System Manufacturer: �-r ® VL' Notice of Acceptance Number: ., Minimum Design Wind Pressures,If Applicable(From RAS 127 or Calculations): Zone 1:-Zone 2e:_Zone 2n:_Zone 2r:_Zone 3e: Zone 3r: Deck Type: Type Underlayment: Roof Slope: 2 Insulation Fire Barrier: Ridge Ventilation? Fastener Type&Spacing: Adhesive Type: � n Type Gap Sheet: ` T r Mean RooF'Height: Roof Covering: Type&Size DripT'�� Edge: 2-k� n �1q RFCF�Fp NEMO I etc. C did Certificate'of Authorization#32455 64'��'�or 353 Christian Street,Unit#13 Oxford,CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT EVALUATION .O. Tarco Roofing Evaluation Report T37910.06.11-R6 One Information Way,Suite 225 FL14672-R6 Little Rock,AR 72202 Date of Issuance:06/23/2011 Revision 6:•08/04/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 7th Edition(2020)Florida.Building Code sections noted herein. DESCRIPTION: LeakBarrier®Modified Bitumen Roof Systems LABELING: Labeling shall be in accordance with the requirements of the:Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, .LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). MEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements,with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOletc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire,Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4, plus a 7-page Appendix. Prepared by: _ j,,g�p_34489 Robert J.M. Nieminen,P.E. „+; .:-sr,.,; The facsimile seal appearingwas authorized by Robert '•F Florida Registration No.59166,Florida DCQ ANE2983 %�5�t"^:kyE«;''. Nieminen,P.E.on 08/04/2020.This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 02019 NEMO ETC,LLC file C®py *NEMO etc. 1. SCOPE: Product Category: Roofing Sub-Category: Modified Bitumen Roof Systems Compliance Statement: LeakBarrier® Modified Bitumen Roof Systems, as produced by Tarco Roofing, have demonstrated compliance with the following sections of the 7th Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: . Section Property Standard Year 1504.3.1 Wind resistance FM 4474 2011 1504.6 Physical properties ASTM G155 2013 1504.7 Impact resistance FM 4470,Section 4.6 2016 1507.1.1 Material standard ASTM D1970 2015 1507.10.2 Material standard ASTM D226 2009 1507.10.2 Material standard ASTM D4601 2012 1507.11.2 Physical Properties ASTM D6163 2015 1507.11.2 Physical Properties ASTM D6164 2011 1507.11.2 Material standard ASTM D6222 -2011, 3. REFERENCES; Entity Examination Reference Date ERD(TST6049), FM 4474 T36510.05.11 05/12/2011 ERD(TST6049) FM 4470 T39050.11.11 11/18/2011 ERD(TST6049) Criticality T39040.11.11 11/21/2011 ERD(TST6049) ASTM D6222(TX) T35450.12.11 12/21/2011 ERD(TST6049) FM 4474 K39690SC 03/07/2012 ERD(TST6049) FM 4470,Section 4.6 T40800.02.12 02/22/2012 ERD(TST6049) ASTM D6222(TX) T43940.05.13 05/01/2013 ERD(TST6049) ASTM D4601(TX) T43410.05.13 05/23/2013 ERD(TST6049) FM 4474 TAR-SC7960.01.16 01/31/2016 ERD(TST6049) FM 4474 TAR-SC5670.03.16 03/21/2016 ERD(TST6049) ASTM D226(TX) TAR-SC13965.02.17-RI 02/27/2017 ERD(TST6049) FM 4474 T6460.06.07-R2 05/26/2017 ERD(TST6049) ASTM D6163(TX) T6470.08.07-R2 06/02/2017 ERD(TST6049) ASTM D4601(TX) TAR-SC16545.11.17 11/01/2017 NEMO(TST6049) ASTM D6164(TX) 4-TAR-18-002.04.18 04/16/2018 MEMO(TST6049) Criticality 4i-TAR-2-SSCRT-01.A 07/17/2020 PRI(TST5878) ASTM D1970(TX) BRY-018-02-01 08/11/2003 Tarco Roofing FBC Cross-List Listing Agreement 01/26/2020 UL(QUA1743) Quality Assurance Service Confirmation 04/07/2020 NEMO ETC,LLC Evaluation Report T37930.06.11-R6 Certificate of Authorization#32455, 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL14672-R6 LeakBarrier®Modified Bitumen Roof Systems Revision 6: 08/04/2020 Page 2 of 4 fONEMOJetc. 4. PRODUCTDESCRIPTION - This Evaluation Report covers LeakBarrier® Modified Bitumen`Roof Systems installed in accordance with Tarco Roofing published installation instructions and the Limitations/Conditions of Use herein. The following products make up the subject systems. ' TABLE 1:ROLL-GOODS FOR LEAK9ARRIER0 MODIFIED BITUMEN ROOF SYSTEMS Material Standard , Type product -Plant(s) Reference.- Type Grade.. LeakBarrier®EasyLay'" ASTM D226 II N/A TX Base Sheets LeakBarrier®EasyNailBaser" ASTM D4601 II N/A, TX LeakBarrier®MS300,• ASTM D1970 N/A N/A. TX TopShield Ice&Water G300 ASTM D1970 N/A. N/A TX Smooth Surfaced Membranes: LeakBarrier®EasyBase'"" ASTM D4601 II N/A TX LeakBarrier®EasyTorch'"SA Base ASTM D4601 11 N/A TX LeakBarrier®EasyTorch''APP Smooth ASTM D6222 I S 'TX Granule Surfaced LeakBarrier®EasyStick Plus'"' ` ASTM D6164 I G TX Membranes: LeakBarrier®EasyTorch'"APP Granular. ASTM D6222 I G TX 5: . 'LIMITATIONS: 5.1 This'is a Building Code Evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was u'sed for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High-Velocity Hurricane,Zone;jurisdictions (i.e., Broward and Miam'i- Dade Counties). 5.3 This Evaluation Report pertains to above-deck roof components. Roof-decks and-structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation_of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and'Aimitations concerning the use of foam plastic insulation. 5.5 This Evaluation Report does not include evaluation of roof edge termination: Refer to FBC 1504.5 for requirements and limitations regarding edge securement for low-slope roofs. 5.6 Refer to FBC 1511 for-requirements and limitations regarding recover installations. 5.6.1 For mechanically attached components over existing roof decks,fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 5.6.2 For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ANSI/SPRI IA-1,ASTM E907,FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.6.3 For bonded insulation or membrane over existing substrates in a recover installation,the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction,as documented through field uplift testing in accordance with ASTM E907,FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 5.7 Refer to Appendix 1 for system attachment requirements for wind load resistance. NEMO ETC,LLC' Evaluation Report T37910.06.11-R6 Certificate of Authorization#32455 1 7-EDITION(2020)FBC NON-HVHZ EVALUATION - FL14672-116 LeakBarrier°.Modified Bitumen Roof Systems Revision 6: 08/04/2020 Page 3 of 4 i I NNEMOjetc- 5.7.1 "MDP"=Maximum Design Pressure is the result of testing for wind load resistance,based on allowable wind loads, and reflects the,ultimate,passing pressure divided by-2 (the 2 to,1-margin of'safety per FBC.,1504.9.has already been applied). Refer to FBC 1609 for determination of design wind loads, 5.7.2 For mechanically attached components or partially-bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure-determined in accordance with FBC Chapter 16, Elevated pressure zones'shall'6mpfoy an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI:WD1, FM Loss Prevention.Data Sheet 1-29,Roofing Application Standard RAS 117 and Roofing.Application Standard RAS 137. Assemblies marked with an asterisk*carry the limitations set forth imSectioh 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(February 2020)for Zone'2/3 enhancements. . 5.7.3 For assemblies with all components fully bonded in place,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC.Chapter 16. No rational analysis is permitted for these systems: 5.8 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3, Refer to the Product Approval of the,component manufacturer for components listed in Appendix 1 that are produced-by a Product Manufacturer other than the report holder,on Page 1 of this Evaluation Report. . 6 INSTALLATION:` LeakBarrier° Modified Bitumen Roof Systems shall be installed in accordance with Tarco Roofing,published installation instructions,subject to the Limitations/Conditions of Use_noted herein. 7. BUILDING PERMIT'REQUIREMENTS: As required by the Building Official or Authority Having`Jurisdiction to properly evaluate the installation of this product. 8 ; MANUFACTURING PLANTS: Contact the named:QA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material,standards. ,9. QUALITY ASSURANCE'ENTITY: Underwriters Laboratories—QUA1743;'(414)248-6409;Karen.buchmann@us.ul.com -THE SEVEN(7)PAGES THAT FOLLOWS FORM PART OF THIS EVALUATION REPORT NEMO ETC,LL0 Evaluation Report T37910.06.11-R6 Certificate of Authorization#31455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL14672-R6 LeakBarrier®Modified Bitumen Roof Systems Revision 6: 08/04/2020 Page 4 of 4 NN-EMO-1 etc. TABLE DECK APPLICATION TYPE DESCRIPTION PAGE 1A Wood New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 2 1B Wood New,Reroof(Tear-Off)or Recover D Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 3 1C Wood New or Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet(nails),Bonded Roof Cover 4-5 1D Wood New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet(screws&plates),Bonded Roof Cover 6 1E Wood New or Reroof(Tear-Off) F_ Non-Insulated,Bonded Roof Cover 7 2A Structural concrete New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 7 The following notes apply to the systems outlined herein: 1 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 2 Unless otherwise noted,fasteners and stress plates shall be as follows. Fasteners shall be of sufficient length for the following engagements: ➢ Wood: OMG#12 or#14 HD with OMG 3 in.Galvalume Steel Plate(non-ribbed)or Trufast#12 DP or#14 HD with Trufast 3"Metal Insulation Plates. Minimum%-inch plywood penetration or minimum 1- inch wood plank embedment. 3 Unless otherwise noted,insulation may be any one layer or combination of FBC Approved(Local or Statewide)board(s)that meet FBC 1505 and,for foam plastic,FBC Chapter 26,when installed with the roof cover. 4 Preliminary insulation attachment for System,Type D:Unless otherwise noted,refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29(February 2020). 5 For mechanically attached components or partially-bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed-at least the Zone 1 PRIME design pressure determined in accordance with FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDl,FM Loss Prevention Data Sheet 1-29,Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137.-Assemblies marked with an asterisk*carrythe limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(February 2020)for Zone 2/3 enhancements. 6 For assemblies with all components fully bonded,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 7 For mechanically attached components over existing decks,fasteners shall.be tested in the existing deck for withdrawal resistance. A qualified'design professional shall review the data for comparison to the minimum'requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105., 8 For bonded insulation or membrane over existing substrates in a re-roof(tear off)or recover installation,the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question,field uplift testing in accordance shall be conducted on mock-ups of the proposed new roof assembly. For bonded insulation or membrane over existing substrates in a recover installation,the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction,as documented through field uplift testing. Field uplift testing shall be in accordance with ASTM E907,FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 9 Refer to FBC 1511 for requirements and limitations regarding recover installations. For Recover Applications using System Type C-1,C-2,D-1 or D-2,the insulation is optional. Alternatively,an FBC Approved insulation board or coverboard may be used as a separation layer. Board products shall be preliminarily attached prior to roof cover installation. The separator component shall be documented as.meeting FBC -1505 and,for foam plastic,FBC Chapter 26,when installed with the roof cover in Recover applications._ 10. "MDP"=Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads.Refer to FBC 1609 for determination of design wind loads. NEMO ETC,LLC Evaluation Report T37910.06.11-R6 for FL14672-R6 Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION Revision 6:08/04/2020 02019 NEMO ETC,LLC LeakBarrier®Modified Bitumen Roof Systems;(254)913-7750 Appendix 1,Page 1 of 7 MEMO etc. SYSTEM TYPE,C, MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System Deck Top insulation Layer Roof Cover MDP No. (Note 1) Base Insulation Layer Type Fasteners Attach Base Ply Ply Cap (Psf) SELF-ADHERING BASE PLY: Min.15/32" (Optional)One or more Min.3/8-inch'SECUROCK Gypsum- l per EasyBase,self- (Optional)EasyBase,self-'' EasyStick Plus,self- W-1. plywood at max., layers,any combination, Note 2 Z, -52.5 24"spans loose laid Fiber Roof Board 1.0ft adhering' adhering adhering Min:15/32" (Optional)One or more EasyTorch SA' (Optional)EasyTorch SA Base, EasyTorch APP Smooth Min.3/8-inch SECUROCK Gypsum-, 1 per W-2. plywood at max. layers,any combination,' Fiber Roof Board 'Note 2 1.0 ftZ Base,self- self-adhering or EasyTorch APP or Granular,torch- -52.5 24"spans loose laid adhering Smooth,torch-applied applied LeakBarrier Min.15/32" (Optional)One or more MS300 or EasyTorch APP Smooth Min.3/8-inch SECUROCK Gypsum-- 1 per (Optional)EasyTorch APP W-3. plywood at max. layers,any combination, . Fiber Roof Board Note 2 10 ftZ TopShield Ice& Smooth,torch-applied, or Granular,torch- -52.5 24"spans loose laid Water G300,self- applied . . . adhering Min.15/32" (Optional)One or more Min.2-inch ACFoam II,EnergyGuard W 4. plywood at max layers,any combination, Polyiso„ 1.0ft ENRGY 3,H-Shield,ISO 95+ Note 2 . 1 per" adhering adhering -82'5 EasyBase,self- (Optional)EasyBase,self- EasyStick Plus,self- adhering24"spans loose laid GL or Multi-Max FA3 Min.15/3r (Optional)One or more Min.,2-inch.ACFoam II,EnergyGuard EasyTorch SA (Optional),EasyTorch SA Base, EasyTorch APP Smooth 1 per: , W-S, plywood at max layers,any combination, Polyiso,ENRGY 3,H-Shield,ISO'95+ Note 2 ' 1.0 ftZ Base,self- self-adhering or EasyTorch APP or Granular,torch- -82.5 24"spans loose laid GL or Multi-Max FA3 adhering Smooth,torch-applied applied LeakBarrier Min.15/32" (Optional)One or more Min.2-inch ACFoam II,EnergyGuard 1 MS300 or EasyTorchEasyTorch APP EasyTorch APP Smooth per W-6. plywood at max. layers,any combination, Polyiso,ENRGY 3,H-Shield,ISO95+ Note 2 1.per TopShield Ice& Smooth,torch-applied or Granular,torch- -82.5 ftZ M'spans loose laid GL or Multi-Max FA3 Water-G300,self- applied adhering TORCH-APPLIED BASE PLY. Min.15/32" (Optional)One or more-, EasyTorch APP EasyTorch APP Smooth Min.3/8-inch SECUROCK Gypsum- 1 per (Optional)EasyTorch APP W-7. plywood at max. layers,any combination, Note 2 Smooth,.torch- or Granular,torch- -52.5 Fiber Roof Board 1:0 ftZ Smooth,torch-applied - 24" loose laid applied applied MEMO ETC,LLC Evaluation Report T37910.06.11-R6for F1.14672-116 Certificate of Authorization#32455 77N EDITION(2020)FBC NON-HVHZ EVALUATION Revision 6:08/04/2020 ©2019 NEMO ETC,LLC LeakBarrier®Modified Bitumen Roof Systems;(254)913-7750 Appendix 1,Page 2 of 7 MEMO 0 etc. TABLE IB: •es sCONSTRUCTION, •e• • RECOVER • INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOFCOVER System Deck Insulation Layer Base Sheet Roof Cover MDP No. (Note 1) Type Attach Type Fasteners Attach Base Ply Ply Cap Ply (psf) SELF-ADHERING BASE PLY: Min.15/32" Any type, 10-inch o.c.in the min.4-inch lap and W-8.__ _ plywood at max. thickness or Loose EasyLay Note 2 10-inch o.c.in two(2),equally EasyBase,self- (Optional)EasyBase,self- EasyStick Plus,self- -60.0 24"spans combination laid spaced,staggered center rows adhering adhering adhering Min.15/32" Any type, Loose 10-inch o.c.in the min.4-inch lap and EasyTorch SA (Optional)EasyTorch SA Base, EasyTorch'APP W-9. plywood at max. thickness or laid EasyLay Note 2 10-inch o.c.in two(2),equally Base,self- self-adhering or EasyTorch Smooth or Granular, -60.0 24"spans combination spaced,staggered center rows adhering APP Smooth,torch-applied torch-applied LeakBarrier Min.15/32" Any type, Loose 10-inch o.c.in the min.4-inch lap and MS300 or (Optional)EasyTorch APP EasyTorch APP W-10. plywood at max thickness or laid Easyl_ Smooth,torch-applied ay Note 2 10-inch o.c.in two(2),equally TopShield Ice& Smooth or Granular, -60.0 24"spans combination spaced,staggered center rows Water G300, torch-applied self-adhering Min.15/32" Anytype, 8-inch o.c.in the min.4-inch lap and W-11. plywood at max. thickness or Loose EasyLay Note 2 8-inch o.c.in four(4),equally spaced, EasyBase,self- (Optional)EasyBase,self- EasyStick Plus,self- -135.0 24"spans combination staggered center rows laid adhering adhering adhering Min.15/32" Anytype, 8-inch o.c.in the min.4-inch lap and EasyTorch SA (Optional)EasyTorch SA Base, EasyTorch APP W-12. plywood at max thickness or Loose EasyLay Note 2 8-inch o.c.in four(4),equally spaced, Base,self- self-adhering or EasyTorch Smooth or Granular, -135.0 P Vw laid Y Y. � ) q Y P g Y 24"spans combination staggered center rows adhering APP Smooth,torch-applied torch-applied LeakBarrier Min.15/32" Anytype, 8-inch o.c.in the min.4-inch lap and MS300 or (Optional)EasyTorch APP EasyTorch APP Loose W-13. plywood at max. thickness or EasyLay Note 2 8-inch o.c.in four(4),equally spaced, TopShield Ice& Smooth or Granular, -135.0 24"spans combination laid staggered center rows Water G300, Smooth,torch-applied torch-applied self-adhering Min.15/32" Anytype, Loose 6-inch o.c.in the min.4-inch lap and EasyBase,self- (Optional)EasyBase,self- EasyStick Plus,self- W-14. plywood at max. thickness or EasyNailBase Note 2 6-inch o.c.in four(4),equally spaced, -135.0 laid adhering adhering adhering 24"spans combination staggered center rows Min.15/32" Any type, Loose 6-inch o.c.in the min.4-inch lap and EasyTorch SA (Optional)EasyTorch SA Base, EasyTorch APP W-15. plywood at max. thickness or EasyNailBase Note 2 6-inch o.c.in four(4),equally spaced, Base,self- self-adhering or EasyTorch Smooth or Granular; -135.0 24"spans combination laid staggered center rows adhering APP Smooth,torch-applied torch-applied LeakBarrier Min.15/32" Anytype, 6-inch o.c.in the min.4-inch lap and MS300 or EasyTorch APP lard Smooth W-16. plywood at max. thickness or Loose EasyNailBase Note 2 6-inch o.c.in four(4),equally spaced, TopShield Ice& (Optional)EasyTorch APP Smooth or Granular, -135.0 24"spans combination staggered center rows Water G300, ,torch-applied torch-applied self-adhering TORCH-APPLIED BASE PLY: - - Min.15/32" -Any type, 6-inch Loose o.c.in the min.4-inch lap and EasyTorch APP EasyTorch APP(Optional)EasyTorch APP W-17. plywood at max. thickness or laid EasyNailBase Note 2 6-inch o.c.in four(4),equally spaced, Smooth,torch- Smooth torch-applied Smooth or Granular, -135.0 24"spans combination ,staggered center rows applied torch-applied NEMO ETC,LLC Evaluation Report T37910.06.11-R6 for FL14672-116 Certificate of Authorization#32455 77H EDITION(2020)FBC NON-HVHZ EVALUATION Revision 6:08/04/2020 02019 MEMO ETC,LLC LeakBarrier®Modified Bitumen Roof Systems;(254)913-7750 Appendix 1,Page 3 of 7 �NNEMO I etc. ••P DECKS—NEW CONSTRUCTION or REROO Offl • BONDED ROOF COVER System Deck Base Sheet Roof Cover MDP No. (Note 1) Type Fasteners Attach Base Ply Ply Cap Ply (Psf) SELF-ADHERING BASE PLY: 12 ga.annular ring shank nails Min.19/32" inch o.c.in three(3),equally EasyBase,self-adhering 7-inch o.c.in the 4-inch lap and 7- W-18. plywood at max. EasyLay and min.32 ga.,1-5/8" (Optional)EasyBase,self- EasyStick Plus,self- -60.0 diameter tin-caps. (Ref: FBC adhering adhering 24"spans 1517.5) spaced,staggered center rows 12 ga.annular ring shank nails Min.19/32" and min.32 ga.,1-5/8" EasyTorch SA Base,7-inch o.c.in the 4-inch lap and 7- (Optional)EasyTorch SA Base, EasyTorch APP W-19. plywood at max. EasyLay inch o.c.in three(3),equally self-adhering or EasyTorch Smooth or Granular, -60.0 24"spans diameter tin-caps. (Ref: FBC spaced,staggered center rows self-adhering APP Smooth,torch-applied torch-applied 1517.5) 12 ga.annular ring shank nails Min.19/32" 7-inch o.c.in the 4-inch lap and 7- LeakBarrier MS300 or- EasyTorch APP and min.32 ga.,1-5/8" (Optional)EasyTorch APP W-20. plywood at max. EasyLay inch o.c.in three(3),equally TopShield Ice&Water Smooth or Granular, -60.0 , diameter tin-caps. (Ref: FBC Smooth torch-applied 24"spans 1517.5) spaced,staggered center rows G300,self-adhering torch-applied ' Min.15/32" 8-inch o.c.in the min.4-inch lap and (Optional)EasyBase,self- EasyStick Plus,self- W-21. plywood at max. EasyLay Simplex MAXX Cap Fastener 8-inch o.c.in four(4),equally EasyBase,self-adhering adhering adhering 82.5 24"spans spaced,staggered center rows Min.15/32" 8-inch o.c.in the min.4-inch lap and EasyTorch SA Base, (Optional)EasyTorch SA Base, EasyTorch APP W-22. plywood at max. EasyLay Simplex MAXX Cap Fastener 8-inch o.c.in four(4),equally self-adhering or EasyTorch Smooth or Granular, -82.5 24"spans spaced,staggered center rows self-adhering APP Smooth,torch-applied torch-applied Min.15/32" 8-inch o.c.in the min.4-inch lap and 'LeakBarrier MS300 or. EasyTorch APP W-23. plywood at max EasyLay. Sim lex MAXX Ca Fastener 8-inch o.c.in four(4),equally TopShield Ice&Water (Optional)EasyTorch APP Smooth or Granular, -82.5 P Ywp P ( ) q y P torch-applied 24"spans spaced,staggered center rows G300,self-adhering Smooth, torch-applied 12 ga.annular ring shank nails Min.15/32" 4 4-inch o.c.in the 4-inch lap and and min.32 ga.,1-5/8" (Optional)EasyBase,self- EasyStick Plus,self- W-24. plywood at max. EasyLay inch o.c.in four(4),equally spaced, EasyBase,self-adhering. -120.0 24"spans diameter tin-caps. (Ref: FBC staggered center rows adhering adhering 1517.5) 12 ga.annular ring shank nails Min.15/32" - 4-inch o.c.in the 4-inch lap and 4 . .(Optional)EasyTorch SA Base, EasyTorch APP.. _ and min.32 ga.,1-5/8" EasyTorch SA Base, W-25. plywood at max. EasyLay inch o.c.in four(4),equally spaced, self-adhering or EasyTorch Smooth or Granular, 120.0 24"spans 1517.5) diameter tin-caps. (Ref: FBC staggered center rows self-adhering APP Smooth,torch-applied torch-applied 12 ga.annular ring shank nails Min.15/32" 4-inch o.c.in the 4-inch lap and 4 LeakBarrier MS300 or EasyTorch APP and min.32 ga.,1-5/8" (Optional)EasyTorch APP W-26. plywood at max. EasyLay. diameter tin-caps. (Ref:.FBC Smooth,torch-applied inch o.c.in four(4),equally spaced, TopShield Ice&Water Smooth or Granular, -120.0 24"spans 1517.5) staggered center rows G300,self-adhering torch-applied 12 ga.annular ring shank nails Min.15/32" 4-inch o.c.in the 4-inch lap and 4 and min.32 ga.,1-5/8" (Optional)EasyBase,self- EasyStick Plus,self- W-27. plywood at max EasyNailBase inch o.c.in five(5),equally spaced, EasyBase,self-adhering, -120.0 24"spans diameter tin-caps. (Ref: FBC staggered center rows adhering adhering 1517.5) MEMO ETC,LLC Evaluation Report T37910.06.11-R6 for FL14672-R6 Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION Revision 6:08/04/2020 ©2019 NEMO ETC,LLC LeakBarrier®Modified Bitumen Roof Systems;(254)913-7750 Appendix 1,Page 4 of 7 NNEmojetc. TABLE 1C:,WOOD DECKS—NEW CONSTRUCTION or REROOF(Tear-Off) • • e ALLY ATTACHED BONDED ROOF COVER System Deck Base Sheet Roof Cover MDP No. (Note 1) Type Fasteners Attach Base Ply Ply 'Cap Ply (Psi 12 ga.annular ring shank nails Min.15/32" 4-inch'o.c.in the 4-inch lap and 4 (Optional)EasyTorch SA Base, EasyTorch APP and min.32 ga.,1-5/8" EasyTorch SA Base, W-28, plywood at max. EasyNailBase inch o.c.in five(5);equally spaced, self-adhering or EasyTorch Smooth or Granular, -120.0 diameter tin-caps. (Ref: FBC self-adhering 24"spans - - staggered-center rows APP Smooth,torch-applied torch-applied 12 ga.annular ring shank nails Min.15/32" 4,inch o.c.in the 4-inch lap and 4-. LeakBarrier MS300 or EasyTorch APP and min.32 ga.,1-5/8" (Optional)EasyTorch'APP W-29.- plywood at max. EasyNailBase inch o.c.in five(5),equally spaced, TopShield Ice&Water Smooth or Granular, -120.0 .. diameter tin-caps. (Ref: FBC Smooth,torch-applied 24"spans 1517.5) staggered center rows . G300,self-adhering torch-applied ,TORCH-APPLIED BASE PLY: Min.15/32" 9-inch o.c.in the min.,2-inch lap and (Optional)EasyTorch P EasyTorch APP W-30. plywood at max. EasyNailBase Simplex MAXX Cap Fastener' "18-inch o.c.in two(2),equally APP Smooth,torch- (Optional)EasyTorch APP Smooth or Granular, -45.0* 24"s ans Smooth,torch-applied s�aced sta erect center.rows applied torch-a d P P gg PP PPlie Min.15/32" 9-inch o.c,in the min.2-inch lap and (Optional)EasyTorch EasyTorch APP W-31. plywood at max. EasyNailBase Simplex MAXX Cap Fastener 12-inch ox.in two(2),equally APP Smooth,torch- (Optional)'EasyTorch APP Smooth or Granular, -52.5 24"spans spaced,staggered center rows applied Smooth,torch-applied torch-applied Min.15/32" 6-inch o.c.in the min.2-inch lap and (Optional)EasyTorch EasyTorch APP (Optional)EasyTorch APP W-32. plywood at max. EasyNailBase Simplex MAXX Cap Fastener 6-inch o.c.in two(2),equally APP Smooth,torch- Smooth or Granular, -90.0 Smooth,torch-applied 24"spans spaced,staggered center rows applied torch-applied Min,15/32" 6-inch o.c.in the min.2-inch lap and (Optional)EasyTorch EasyTorch APP W-33. plywood at max. EasyNailBase Simplex MAXX Ca Fastener 6-inch o.c.in three 3,e uall APP Smooth,torch- (Optional)EasyTorch APP Smooth or Granular, -105.0 P Yw y P P ( � q y Smooth,torch-applied 24"'spans spaced,staggered center rows applied torch=applied 12 ga.annular ring shank nails Min,15/3T' 4-inch o.c.in-the flinch lap and 4 (Optional)EasyTorch EasyTorch APP and min.32 ga.,1-5/8" (Optional)EasyTorch APP E plywood at max. EasyNailBase inch o.c.in five(5),equally spaced,- APP Smooth,torch- Smooth or Granular, -120.0 diameter tin=caps.,(Ref: FBC Smooth,torch-applied 24"spans' 1517.5) staggered center rows applied torch-applied NEMO ETC,LLC Evaluation Report T37916.06.11-116 for FL34672-R6 Certificate of Authorization#32455 ` """ 7-EDITION(2020)FBC NON-HVHZ EVALUATION Revision 6:08/04/2020 ©2019 NEMO ETC,LLC LeakBarrier®Modified Bitumen Roof Systems,(254)913-7750 Appendix 1,Page 5 of 7 NNEMOjetc. TABLEID. WOOD B ONSTRUCTION R�KOOF • a B a a aB a :0 B B '•• COVER, System Deck Base Sheet Roof Cover MDP No. (Note 1) Type Fasteners Attach Base Ply Ply Cap Ply (Psf) SELF-ADHERING BASE PLY: - Min.15/32" 10-inch o.c.in the min.4-inch lap and 10-inch o.c. (Optional)EasyBase,self- EasyStick Plus,self- W-35. plywood at max. EasyLay Note 2 in two(2),equally spaced,staggered center rows EasyBase,self-adhering adhering adhering -60.0 24"spans Min.15/32" 10-inch o.c.in the min.4-inch lap and 10-inch o.c. EasyTorch SA Base,self- (Optional)EasyTorch SA Base, EasyTorch APP W-36. plywood at max. EasyLay Note 2 self-adhering or EasyTorch APP Smooth or Granular, -60.0 in two(2),equally spaced,staggered center rows adhering 24"spans Smooth,torch-applied torch-applied Min.15/32" 10-inch o.c.in the min.4-inch lap and 10-inch o.c. LeakBarrier MS300 or (Optional)EasyTorch APP EasyTorch APP W-37. plywood at max. EasyLay Note 2 in two(2),equally spaced,staggered center rows TopShield Ice&Water Smooth,torch-applied Smooth or Granular, -60.0 24"spans G300,self-adhering torch-applied Min.15/32" 8-inch o.c.in the min.4-inch lap and 8-inch o.c.in (Optional)EasyBase,self- EasyStick Plus,self- W-38. plywood at max. EasyLay. Note 2 four(4),equally spaced,staggered center rows EasyBase,self-adhering. adhering adhering -135.0 24"spans Min.15/32" (Optional)EasyTorch SA Base, EasyTorch APP 8-inch o.c.in the min.4-inch lap and 8-inch o.c.in EasyTorch"SA Base,self- W-39. plywood at max. EasyLay Note 2 four(4),equally spaced,staggered center rows adhering self-adhering or EasyTorch APP Smooth or Granular, -135.0 24"spans Smooth,torch-applied torch-applied Min.15/32" LeakBarrier MS300 or EasyTorch APP 8-inch o.c.in the min.4-inch lap and 8-inch o.c.in (Optional)EasyTorch APP W-40. plywood at max. EasyLay Note 2 four(4),equally spaced,staggered center rows TopShield Ice&Water Smooth,torch-applied Smooth or Granular, -135.0 24"spans G300,self-adhering torch-applied Min.15/32" 6-inch o.c.in the min.4-inch lap and 6-inch o.c.in (Optional)EasyBase,self- EasyStick,Plus,self- W-41. plywood at max. EasyNailBase Note 2 EasyBase,self-adhering -135.0 four(4),equally spaced,staggered center rows adhering adhering 24"spans Min.15/32" (Optional)EasyTorch SA Base, EasyTorch APP W-42. plywood at max. EasyNailBase Note 2 four( o.c.in the min.4-inch lap and 6-inch rosin EasyTorch SA Base,self- self-adhering or EasyTorch APP Smooth or Granular, -135.0 24"s ans four(4),equally spaced,staggered center rows adhering Smooth,torch-applied torch-applied P PP pP Min.15/32" LeakBarrier MS300 or EasyTorch APP 6-inch o.c.in the min..4-inch lap and 6-inch o.c.in (Optional)EasyTorch APP four( W-43, plywood at max. EasyNailBase Note 2 equally spaced,staggered center rows TopShield Ice&Water Smooth,torch applied Smooth or Granular, -135.0 4), 24"spans G300,self-adhering torch-applied TORCH-APPLIED BASE PLY: Min.15/32" 6-inch o.c.in the min.4-inch lap and 6-inch o.c.in (Optional)EasyTorch APP (Optional)EasyTorch APP EasyTorch APP W-44. plywood at max. EasyNailBase Note 2 Smooth or Granular, -135.0 24"spans four(4),equally spaced,staggered center rows Smooth,torch-applied Smooth;torch-applied torch-applied NEMO ETC,LLC Evaluation Report T37910.06.11-R6 for FL14672-R6 Certificate of Authorization#32455 7'"EDITION(2020)FBC NON-HVHZ EVALUATION Revision 6:08/04/2020 02019 NEMO ETC,LLC LeakBarrier'Modified Bitumen Roof Systems,(254)913-7750 Appendix 1,Page 6 of 7 ONEMOletc. TABLE IE: WOOD DECKS—NEW CONSTRUCTION or REROOF(Tear-Off) :• • • ROOF COVER System Deck(Note 1) Roof Cover MDP No. Type Joint Treatment Base Ply Ply Cap (Psf) W 45 Min.15/32"plywood None (Optional)EasyBase,self-adhering (Optional)EasyBase,self-adhering EasyStick Plus,self- -75.0 at max.24"spans adhering - W-46.- Min.15/32"plywood-- None EasyTorch SA Base,serf-adhering (Optional)EasyTorch SA Base,self-adhering EasyTorch APP Smooth or -75.0 at max.24"spans or EasyTorch APP Smooth,torch-applied Granular,torch-applied Min.15/32"plywood LeakBarrier MS300 or TopShield Ice (Optional)EasyTorch APP Smooth,torch- EasyTorch APP Smooth or W�7 None at max.24"spans &Water G300,self-adhering applied Granular,torch-applied -75.0 Min.15/32"plywood Plywood joints are covered with 4-inch wide strips of EasyStick Plus,self- W-48. at max.24"spans EasyBase,self-adhering,rolled into place to create (Optional)EasyBase,self-adhering (Optional)EasyBase,self-adhering adhering -120.0 continuous bond. Plywood joints are covered with 4-inch wide strips of Min.15/32"plywood (Optional)EasyTorch SA Base,self-adhering EasyTorch APP Smooth or W 49. at max.24"spans EasyBase,self-adhering,rolled into place to create EasyTorch SA Base,self-adhering or EasyTorch APP Smooth,torch-applied Granular,torch-applied -120.0 continuous bond. Min.15/32"plywood Plywood joints are covered with 4-inch wide strips of LeakBarrier MS300 or TopShield Ice (Optional)EasyTorch APP Smooth,torch- EasyTorch APP Smooth or W-50. EasyBase,self-adhering,rolled into place to create -120.0 at max 24"spans continuous bond. &Water G300,self adhering applied Granular,torch-applied CONCRETETABLE 2A: DE&S NEW CONSTRUCTION ••• • -_SYSTEIVI TYPE.F: NON-INSULATED,BONDED ROOF COVER.-------- System Deck Roof Cover MDP No. (Note 1) Primer Base Ply Ply Cap (psf) C-1. Concrete ASTM D41 EasyTorch APP Smooth,torch-applied (Optional)EasyTorch APP Smooth,torch-applied EasyTorch APP Smooth or Granular,torch-applied -670.0 MEMO ETC,LLC Evaluation Report T37910.06.11-R6 for FL14672-R6 Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION Revision 6:08/04/2020 ©2019 NEMO ETC,LLC LeakBarrier®Modified Bitumen Roof Systems;(254)913-7750 Appendix 1,Page 7 of 7