Loading...
HomeMy WebLinkAbouthealth departmentFLORIDA STATE OF >g�DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM .y Y CONSTRUCTION INSPECTION AND FINAL APPROVAL APPLICANT: Adams Homes of Northwest Florida, Inc AGENT: Benjamin Drew"s Plumbing & Drain Services PROPERTY ADDRESS: 5001 Sunset Blvd Fort Pierce, FL 34982 APPLICATION #:AP1450603 PERMIT #:56-SF-2012264 DOCUMENT # : FI 1588214 DATE PAID:10/29/2019 FEE PAID:545.00 RECEIPT #:56-PID-4210941 LOT: 24 BLOCK: 46 SUBDIVISION: Indian River Estates ID#: 3402-608-0219-000-7 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] [01] TANK SIZE [1] 1090.00 [21 300.00 [ ] [271 SURFACE WATER FT [ ] [021 TANK MATERIAL Polyethylene [ ] [281 DITCHES FT [ ] [031 OUTLET DEVICE [ ] [29] PRIVATE WELLS FT [ ] [041 MULTI -CHAMBERED [ Y N ] [ ] (30] PUBLIC WELLS FT [ ] [051 OUTLET FILTER Polylok PL-68 [ ] [311 IRRIGATION WELLS FT [ ] [061 LEGEND 1. 70-143-11DC4 2, 70-156-03SC3 [ ] [321 POTABLE WATER 47 FT [ ] [071 WATERTIGHT [ ] [33] BUILDING FOUNDATIONS 5 FT [ ] [081 LEVEL [ ] (341 PROPERTY LINES 5 FT [ ] (091 DEPTH TO LID [ ] [351 OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [10] AREA [1] 510 [2] SQFT [ ] [361 DRAINFIELD COVER [ ] [111 DISTRIBUTION BOX HEADER X [ ] [37] SHOULDERS [ ] [121 NUMBER OF DRAINLINES 1. 4.00 2. [ ] [381 SLOPES [ ] (13] DRAINLINE SEPARATION [ ] [391 STABILIZATION 03/08/2021 [ ] [141 DRAINLINE SLOPE [ ] [151 DEPTH OF COVER ADDITIONAL INFORMATION [ ] [16] ELEVATION [ ABOVE / BELOW ]BM 8.00 [ ] [401 UNOBSTRUCTED AREA [ ] [171 SYSTEM LOCATION E ] [411 STORMWATER RUNOFF [ ] [18] DOSING PUMPS 1.00 [ ] [421 ALARMS [ ] [19] AGGREGATE SIZE [ ] [431 MAINTENANCE AGREEMENT [ ] [20] AGGREGATE EXCESSIVE FINES [ ] [441 BUILDING AREA [ ] [211 AGGREGATE DEPTH [ ] (45] LOCATION CONFORMS WITH SITE PLAN FILL / EXCAVATION MATERIAL [ ] [461 FINAL SITE GRADING [ ] [471 CONTRACTOR Bruce T Mc Cullers (Reliable T [ ] [221 FILL AMOUNT [ ] [48] OTHER ADS MPS-9 (9 pipes - 2 tier) [ ] [23] FILL TEXTURE [ ] [241 EXCAVATION DEPTH ABANDONMENT [ ] [25] AREA REPLACED [ ] [491 TANK PUMPED [ ] [26] REPLACEMENT MATERIAL [ ] [501 TANK CRUSHED & FILLED Comments: Comments are on page 2. / St. Lucie CHD DATE: 12/04/2020 CONSTRUCTION [ APPROVED DISAPPROVED Environ ental Specialist II n J Ingram (ENVIRONMENTAL HEALTH) FINAL SYSTEM [ APPROVED / DISAPPROVED ]: St. Lucie CHD DATE: 03/11/2021 Environmental Specialist II rian J Ingram (ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1450600 EID2012264 9" STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL who ws s� Violation Number Comment Comments APPLICATION #:AP1450603 PERMIT #:56-SF-2012264 DOCUMENT # : FI 1588214 DATE PAID:10/29/2019 FEE PAID:545.00 RECEIPT #:56-PID-4210941 The system is sized for 4 bedrooms with a maximum occupancy of 8 persons (2 per bedroom), for a total estimated flow of 400 gpd. New ST, filter, DT, liberty 1/3 hp pump, and 2x40'+2x45' long TRENCH DF installed. No violations, system ok to cover. Contractor notified by phone. Needs final inspection for mound system, gutters, alarm check, final site grading, and pump wired through riser wall in conduit. Final system approved. Contractor, building department, and builder emailed final approval. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1450603 EID2012264