ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET
Florida Building Code 7th Edition (2020)
Based on Section 1525 ofthe Florida Building Code - Building
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED
BELOW:
Roof System
-Application
Required Sections of
the Permit Application
Form
Attachments Required
See List Below
Low Slope
A, _BC
1,2,3AA6,7
Prescriptive BUR-RAS 150
A, B, C
2,4,5,6,7
Asphaltic Shingles
A, B, D
1,2,4,5,6,7
Concrete or Clay Tile
p, B, D, E
12,3,4,587
Metal Roofs
A, B, 11
1,2,3,4A6,T
Wood Shingles and
Shakes
A, B, D
1,2,4,5,6,7
Other
As Applicable
193,4,5,6,7
ATTACHMENTS REQUIRED As Applicable):
1.
Fire Directory Listing Page
2.
From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3.
Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128
4.
Other Component of Product Approval
S.
Municipal Permit Application
6.
Owners Notification for Roofing Considerations (Reroofing Only)
7.
Any Required Roof Testing/Calculation Documentation
Fonn RoaflnfoFeb21 Rev Feb 18, 2021
ST. LUCIE WORKS
Section A (General Information)
Master Permit No.
Process No.
Contractors Name: dA TAYLOR ROOFING Licensee CCC 1325895
15501 MIDWAY ROAD, FORT PIERCE, FL 34945
GiLow Slope
O Asphaltic Shingles
O New roof ❑ Repair
Low Slope Roof Area(SF) 1,100
ROOF CATEGORY
❑ Mechanically Fastened Tile
0 Metal Panel/Shingles
0 Prescriptive BUR-RAS 15C
ROOF ROOF TYPE.
❑ Maintenance
. ROOF SYSTEM INFORMATION
Steep Sloped Roof Area (SF)
❑ Mortar/Adhesive Set Tiles
ClWood Shingles/Shakes
Er Reroofing 13Recovering
Total (SF) 1,100
Section B (Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.
Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets.
ST. LUCIE ;'VORKS
Section C (Low Slope Roof)
Fill in specific roof assembly components and identify
manufacturer
(If a component is not used, identify as "NA")
System Manufacturer: JOHNS MANVILE TPO W-14
Product Approval No.: FL#11475A
Design Wind Pressures, From RAS 128 Or Calculations:
Zone V:_Zone 1:-56.14 Zone 265.82Zone 3: -70.6
Max. Design Pressure, from the specific product approval
system:
Deck:
Type: PLYWOOD
Gauge Thickness: 5/8 CDX
Slope: 1 to/12
Anchor/Base Sheet & No. df ply($): WA
Anchor/Base Sheet Fastener/Bonding Material:
N/A
Insulation Base layer: 2" ISO
Base Insultation Size and Thickness: 2"
Base Insulation Fastener/Bonding Material:
Top Insulation Layer: SECURE ROCK
Top Insulation Size and Thickness:.5"
Top Insulation Fastener/Bonding Material:
4" SCREWS JM HIGHLOAD FASTENERS
Base Sheet(s) & No. of Ply(s): N/A
Base Sheet Fastener/Bonding Material:
N/A
Ply Sheet(s)' & No. of Ply(s): N/A
Ply Sheet Fastener/Bonding Material:
4" HIGH LOAD FASTENERS
Top Ply: N/A
Top Ply Fastener/Bonding Material:
.060TPO 1 PLY
Surfacing: N/A PLEASE SEE ENGINEERING
Fastener Spacing for Anchor/Base Sheet Attachment:
Zone 1':_"
oc @ Lap, If Rows_ ®_ W
Zone 1�"
oc @ Lap, If Rows _ @ — oc
Zone 2—"
oc @ Lap, If Rows —@ _ oc
Zone 3
" oc @ Lap, If Rows_ ®_ oc
Number of Fasteners Per Insulation Board:
Zone 1':Zone 1:—Zone 2:—Zone 3:_
Illustrate Components Noted and Details as Applicable:
Woodblocking, Gutter, Edge Termination, Stripping,
Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterflashing, Coping, Etc..
Indicate: Mean Roof Height, Parapet Height, Height of Base
Flashing, Component Material, Material' Thickness, Fastener
Type, Fastener Spacing or Submit Manufacturers Details that
Comply with RAS 111 and Chapter 16..
S1 LUCIE WORKS
Section D (Steep Slope Roof System)
Roof system Manufacturer:
Notice of Acceptance Number:
Minimum Design Wind Pressures, If Applicable (From RA5127 or Calculations):
Zone 1: Zone 2e: 7one 2n:—Zone 2r: 7one 3e:—Zone 3r:
\Deck Type:
Type Underlaymenh
Roof Sbpe:
12
Insulation:
Fire Bander:
Ridge)Aantatonl Fastener Type&Spacing:
Adhesive Type:
Type Cap Sheet:
Mean Roof Height: I Roof Covering:
Type & Size Drip �—
Fdnc
ST. LUCIE V,:.
Section E (Tile Calculations)
For Moment based tile systems, choose either Method 1 or 2. Compare the values for Mrwith the values From Mr. If the Mr values
are greaterthan or equal to the Mrvalues, for each area of the roof, then the tile attachment method is acceptable.
Method 1'Moment Based Tile Calculations Per RAS 12T
(Zone 1: _x1 = )_ Mg: _=Mri_ Product ApprovalM
(Zone 2e: _xA_= _ )- Mg: _=Mr _ Product ApprovalM
(Zone 2n: '_xa_= _)- Mg; _=Mm_ Product ApprovalM
(Zone 2r. _Xb_= _)- Mg: _=Mg_ Product Approval Mr
(Zone 3e: "xa_> _)-Mg:_=M,ar_ Product ApprovalM
(Zone 3r. =xX-= -Mgt_=M,9_ Product Approval Mr
Method 2 "Simplified Tile Calculations Per Table Below"
Required Moment of Resistance (Mr) From Table Below_Product Approval Mr_
M, required Moment Resistance -
Mean Roof Height Roof Slope
15'
20'
25'
30'
40'
2:12
34.4
36.5
38.2
39.7
42.2
3:12
32.2
34.4
36.0
37.4
39.8
4:12
30.4
32.2
33.8
35.1
37.3
5:12
28.4
30.1
31.6
32.8
34.9
6:12
26.4
28.0
29.4
30.5
32.4
7:12
24.4
25.9
27.1
28.2
30.0
'Must be used in conjunction with a list of moment based tile systems
• For Uplift based tile systems use Method 3. Compare the values for F' with the values for Fr If the F'values are greater than or
equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable.
Method 3 "Uplift Based Tile Calculations Per RAS 12T
(Zone 1:_x LxW:= -W:cos rFrn Product Approval F'
(Zone 2e:_x L=xW:=)-W:cos rFa• Product Approval F'
(Zone 2n: xL_=x W� )-W:_Cosr =Fa" Product Approval F
(Zone 2r:_xL =x W;= )-W: Cos r =Far_ Product Approval F'
(Zone 3e: x l ac W:= ) -W: Cos r Frse Product Approval F'
(Zone 3r: xL=xW:=---)-W:_Cos r =Fo Product Approval F'
Where to Obtain Information
Description
Symbol
Where to find
Design Pressure
Zones 1, 2e, 2n, 2r, 3e, 3r
From applicable table in RAS 127 or by an engineering analysis
prepared by PE based on ASCE 7
Mean Roof Height
H
Job Site
Roof Slope
0
Job Site
Aerodynamic Multiplier
a
Product Approval
Restoring Moment due to Gravity
Ma
Product Approval
Attachment Resistance
Mf
Product Approval
Required Moment Resistance
Ma
Calculated
Minimum Attachment Resistance
F'
Produc[Approval
Required Uplift Resistance
Fr
Calculated
Average Tile Weight
W
Product Approval
Tile Dimensions
L=length W=width
Product Approval
All calculations must be submitted to the building official at the time of permit application.