Loading...
HomeMy WebLinkAboutAPPROVED, roofing permit infoLay ccm L� R ST. LUCIE WORKS ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code - Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Low Slope Application i Pre5criptive BUR-RAS 1So j Asphaltic 5hingles CDncrete or Clay rile r tal Roofs ood Shingles and .Shakes Other Required Sections of the Permit Application Form A, B, C A, B, C A,8,0 A, B, D, E A, B, D As Applicable Attachments Required See List Below 1,2,A4A6,7 2,4,5,6,7 1,2,4.5.8,7 1,2,4„6,6,7 1,2.%4s,6,7 ATTACHMENTS REQUIRED As Applicable): 1. Flre Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Retail Drawings 3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 ............... �........._ ._.......... 4. Othercomponent of Product Approval 5. Municipal Permit Application 6. Owners Notification For Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form RooftnfoFeb21 Rev Feb 18, 2021 ST. LUCIE WORKS Section A (General Information) Master Permit No. Process No. Contractors Name: JA TAYLOR ROOFING License # CCC 1325895 Job Addres 2719 S 29T STREi~T, FC3RT PIEiCE l L 34981 © Low Slope ❑ Asphaltic Shingles © New roof ❑ Repair Low Slope Roof Area (SF) ROOF CATEGORY 0 Mechanically fastened Tile EZMetal Panel/Shingles C3 Prescriptive 13UR-W 150 ROOF ROOF TYPE. © Mortar/Adhesive Set Tiles OWood Shingles/Shakes 0 Maintenance 9 Reroofing -ROOF SYSTEM INFORMATION Steep Sloped Roof Area (SF) _ 2,400 ❑ Recovering Total (SF) 2.400 Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scupoers, overflovi �r E�„�.� ._a __ Inch...,...,:__.. _..., sins. ets. ST. LUCK ¢ a .�,�. � KS Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer - Pro d u ct Approval No.: Design Wind Pressures, From RAS 128 or Calculations: Zane V.' — Zone 1: Zone 2: _____Zone 3: Max. Design Pressure, from the specific product approval system: Deck: Type: Gauge Thickness: Slope: Anchor/Base Sheet & No- df Ply{s): Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer: Base Insultation Size and Thickness: Base Insulation Fastener/Banding Material: Top insulation Layer: Tap Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): Base Sheet Fastener/Handing Material: Ply Sheet(s)' & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: Top Ply Fastener/Bonding Material: Surfacing- Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1 `.--" oc @Lap, # Rows--* ® --2 ac Zone 1" oc @Lap, #Rows 'vc Zone Z:_. it oc @ Lap, # Rows ,,,_ 4 oc Zone 3:—.._." oc @ Lap, # Rows ,. ® _moo Number of Fasteners Per Insulation Board; Zone i': Zone 1: Zone Z Zone 3: Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Cou n terf I a s h i n g, Coping, Etc., Indicate: Mean Roof height, Parapet Height, Height of Base Flashing, Component Material, MateriaP Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Detalls that Comply with RAS 1 11 and Chapter 16.. ST. L UCIE WORKS Section D {Steep Slope Roof System) Roof system Manufacturer: JA TAYLOR ROOFING 5V CRIMP Notice ofArceptance Number: FL#17443.1 Minimurn Design Wind Pressures, 1f Applicable (From RAS 127 or Calculations): Zone 1: Zone 2e:one 2n: Zone 2r:-...Zone 3e: Zone 3r: Type Undemen pEEL & STICtC-PC)LYGLASS MTS FL#5259.1 Ranf Sbp�: rta 5 12 1nsulatioll 1: FFj t rrlBf: ^ Ridge Vsr4on? Fastener Type & Spachg: 8Q RING Sl-fANt{ NAIlwS-E"QC Adhesive Type: _ Type Cap Shot: Meats RoafHeigh#: 15' FT Roof Covering I METAL Type & 812e Drip Edge. ST. LUCIE WORKS Section E (Tile Calculations) For Moment based tide systems, choose either Method ! or 2. Compare the values for Mr with the values from Mr. If the are greater than or equal to the Mf values MrvaIues, for each area of the roof, then the file attachment method is acceptable. Method 1 'Moment Based Tile Calculations Per RAS 12T [zone 1; (Zane 2e: x X � Product Approval Mom. , (Zone 2n: ~ x ;L —= —� _ M7. Mr2o Product Approval Mir x = - Mg; $ MN, Product (Zone 2r. Approval Mf x _j Mg: - Ma product Approval Mf _ (Zane 3e: x X=. _ ft = k4ft Product Approval M}. (Zone3r: XI—m -t4; �M,ar Product Approval Mf. Method 2 "Simplified Tile Calculations Per Table Below° Requited Moment of Resistance (M,} From Table BelOw. Product Approval Mu- . M, required Moment Resistance* m Mean Roof Height Roof Slope i5' NY 25, 30' 40' 34.4 �3:11232.24 30.4 5:12 28.4 5:12 Zfi.4 4 �36.5 32.2 3Q.1 )8 Q 38.2 36.0 33.8 3I.6 29 39.i 37.4 T 42.2 3%8 35.1 37.3 32.8 34.9 �82 �24:12 24.4 25.9 271 'Must be used in conjunction with a list of moment based the systems • For Uplift based the systems use Method 3. Compare the values for F' with the values for F, If the F' values are greater than or equal to the F, values, for each area of the roof, then the the attachment method is acceptable. Method 3 "'Uplift Based Tile Calculations Per RAS 12T (Zone 1: x L =x Vv:=) -W; cos r =Fn Product Approval F' {Zone Ze: x L =x W:= ) -W: cos r =Fr2e Product Approval F' (Zone 2n: x L =x W:= 3 -W: cos r =F,2n Product Approval F' (Zone 2r: , �.,,x L =x W;= _ J _W.. cos r =F,2r Product Approval F' (Zone 3r, x L =x 1N:=_ _} -W: cos r =Fr3e Product Approval F' (Zane 3: x L =x W.= } -W; cos r =Fri Product Approval F'