Loading...
HomeMy WebLinkAboutDensityUES Project No: UES DOCS No: UES Report No: 0310.2000358.0000 134255-1 DT 012921 820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978 In-Place Density Test Report Client:Fulcrum Construction Group, LLC 810 Manci Ave Daphne, AL 36526 Project:Dollar General Store 8736 Ft. Pierce Virginia Avenue & 38th Street, Ft. Pierce, St. Lucie County, FL Area Tested:dumpster pad Type of Test:Field:ASTM D-6938 Nuclear Gauge Method Date of Test:01/29/2021 Lab:ASTM D1557 Modified Proctor Technician:Russell Brause Requirements:95% of Proctor maximum dry density. These tests apply to the fill and/or surficial soil conditions only and do not address the condition of the underlying soils below the tested depths. Test No.Location of Test Range Depth (inch) Proctor (2) Field Dry Density (PCF) Field Moisture % % Compaction Comments (3) 1 Ctr of pad.0 to -1 ft 12.00 26283 108.2 8.1 100 A (1)Ref. Datum: 0 = Top of Final Grade (3) Comments Key (2) Proctor # Maximum Dry Density Optimum Moisture Content 26283 108.0 11.5 A. Compaction meets min. requirements B. Compaction does not meet min. requirements C. Moisture does not meet requirements D. Recompaction required E. Recompacted, Retested, Meets Requirements This test was performed without deviation from ASTM procedures. This report shall not be reproduced, except in full, without the written approval of Universal Engineering Sciences.