Loading...
HomeMy WebLinkAboutCertification for Design Load CompliancePlanning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: Ana & Ted Ferguson Residence Proiect Address: 10854 S. Ocean Drive #84, St. Lucy County, Florida Permit #: Occupancy Type: R3 Construction Type: Type 5 INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code 2010 Edition with 2012 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed Partially Enclosed Open 3. Risk Category: _I X II III IV Exposure Category: B C X D 4. Design Wind Velocity 116 mph X ASD LRFD End Zone Width: 6 ft 5. Mean Roof Height 22 ft Roof Pitch: 0 :12 Parapet: n/a ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: -42psf Zone 2: -60psf Zone 3: -90psf Zone 4: +30/-53 Zone 5: +30/-53 Garage: +21/-24psf 7. Design Loads: Floor: 40 PSF Roof/Dead: 75 PSF Roof/Live: 20 Balcony: 40 PSF Dock: n/a PSF Deck: n/a PSF Stairs: 40 PSF Fence: n/a PSF Railings: 50plf PSF 8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? X Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify tWhmtural elements depicted on these plans provide adequate resistance to the design forces specified: % � ,, ��� Q T P O �W� Robert F. Oleck 52514 -P OPEty••• i Print Name Cert # & Co. Cert Auth. 14 R.F.Oleck,lnc. signature, st r%i'e� 1219 Scarlet Oak Loop, Winter Garden, FL 34787 ••••�R:.•�.••' `��� Company Name & Address Revised 07/25/209, �AL f11111