Loading...
HomeMy WebLinkAboutEnergy CodeFORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 61212141i Builder Name: Street: 10854 SOUTH OCEAN DRIVE #84 Permit Office: ST LUCIE COUNTY City, State, Zip: JENSEN BEACH, FL, 34957- Permit Number. Owner. FERGUSON RESIDENCE Jurisdiction: 661000 Design Location: FL, ST LUCIE CO INTL 1. New construction or existing New (From Plans) 9. Wall Types (1888.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=6.0 1776.00 ft2 b. Frame - Wood, Adjacent R=13.0 112.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (1260.0 sqft.) Insulation Area a. Cathedral/Single Assembly (Unvented) R=1.0 1260.00 ft2 6. Conditioned floor area above grade (ft2) 1481 b. N/A R= _ ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(428.7 sqft.) Description Area a. Sup: 1st Floor, Ret: 1st Floor, AH: 1st Floor 6 296.2 a. U-Factor. Dbl, U=0.38 428.67 ft2 SHGC: SHGC=0.25 b. U-Factor. N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 30.0 SEER:14.00 c. U-Factor. N/A ft2 . SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor. N/A ft2 a. Electric Heat Pump 30.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 4.009 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems a. Electric Tankless Cap: 1 gallons 8. Floor Types (1481.0 sqft.) Insulation Area EF: 0.920 a. Slab -On -Grade Edge Insulation R=0.0 845.00 ft2 b. Conservation features b. Floor Over Other Space R=19.0 636.00 ft2 None c_ WA R= ft2 15. Credits Pstat Glass/Floor Area: 0.289 Total Proposed Modified Loads: 24.50 PASS Total Standard Reference Loads: 36.52 I hereby certify that the plans and specifications covered by Review of the plans and 'CAE S7'.gp�, this calculation are in compliance with the Florida Energy specifications covered by this 0 .y , __ , 0' Code. calculation indicates compliance ki ... ._gg p,, _ �O PREPARED BY: Roy Aboo i #1361 DATE: 12-1 -2014 with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 v hereby certify that this building,s desi ed, is in compliance the Florida Energy Co Florida Statutes. cOD with WE OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist 12/17/2014 5:32 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6 PROJECT Title: 6121214R Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1481 Lot # Owner. FERGUSON RESIDENCE Total Stories: 1 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 10854 SOUTH OCEAN Permit Office: ST LUCIE COUNTY Cross Ventilation: County: St. Lucie Jurisdiction: 661000 Whole House Fan: City, State, Zip: JENSEN BEACH, Family Type: Single-family FL, 34957- New/Existing: New (From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST LUCIE_CO_INTL FL ST LUCIE_CO_INTL 2 39 90 70 75 722 58 Medium BLOCKS Number Name Area Volume 1 Block1 1481 11848 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 1 st Floor 845 6760 Yes 1 1 1 Yes Yes Yes 2 2nd Floor 636 5088 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio 1 st Floor 134 ft 0 845 ft2 — 0 0 1 2 Floor Over Other Space 2nd Floor -_- — 636 ft2 19 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Flat Concrete 1264 ft2 52 ft2 White 0.1 No 0.1 No 22 4.8 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 No attic Unvented 0 1260 ft2 N N 12/17/2014 5:32 PM EnergyGaugeO USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6 CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Cathedral/Single Assembly (Unvente2nd Floor 1 1260 1112 0.11 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below y it mt In Wall Type Space R Valup Ft In Ft In Area R Vahle Fraction Absor Grad ° 1 E Exterior Concrete Block - Int Insul 1st Floor 6 5 8 40.0 ft2 0 0.100000 0 2 E Exterior Concrete Block - Int Insul 1st Floor 6 29 8 232.0 ft2 0 0.100000 0 3 N Exterior Concrete Block - Int Insul 1st Floor 6 19 8 152.0 1112 0 0.100000 0 4 W Exterior Concrete Block - Int Insul 1st Floor 6 45 8 360.0 1112 0 0.100000 0 5 S Exterior Concrete Block - Int Insul 1st Floor 6 22 8 176.0 ft2 0 0.100000 0 6 N Garage Frame - Wood 1st Floor 13 14 8 112.0 ft2 0.23 0.100000 0 7 S Exterior Concrete Block - Int Insul2nd Floor 6 22 8 176.0 ft2 0 0.100000 0 8 E Exterior Concrete Block - Int Insul2nd Floor 6 29 8 232.0 ft2 0 0.100000 0 9 N Exterior Concrete Block - Int Insul2nd Floor 6 22 8 176.0 ft2 0 0.100000 0 10 W Exterior Concrete Block - Int Insul2nd Floor 6 29 8 232.0 ft2 0 0.100000 0 DOORS # Omt Door Type Space Stones U Value Width Height Area Ft In Ft In 1 E Wood 1st Floor None .46 5 4 6 8 35.6 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 E 1 Vinyl Double (Clear) Yes 0.38 0.25 24.0 ft2 9 ft 0 in 0 ft 0 in None Exterior 5 2 E 2 Vinyl Double (Clear) Yes 0.38 0.25 32.0 ft2 1 it 9 in 1 ft 2 in None Exterior 5 3 N 3 Vinyl Double (Clear) Yes 0.38 0.25 32.0 111:2 1 ft 9 in 1 ft 2 in None Exterior 5 4 W 4 Vinyl Double (Clear) Yes 0.38 0.25 16.0 ft2 0 it 2 in 14 ft 0 in None Exterior 5 5 W 4 Vinyl Double (Clear) Yes 0.38 0.25 18.7 ft2 0 ft 2 in 14 ft 0 in None Exterior 5 6 W 4 Vinyl Double (Clear) Yes 0.38 0.25 32.0 ft2 0 ft 2 in 14 ft 0 in None Exterior 5 7 S 5 Vinyl Double (Clear) Yes 0.38 0.25 90.0 ft2 1 ft 9 in 1 ft 2 in None Exterior 5 8 S 7 Vinyl Double (Clear) Yes 0.38 0.25 24.0 ft2 17 it 0 in 0 It 0 in None Exterior 5 9 S 7 Vinyl Double (Clear) Yes 0.38 0.25 40.0 ft2 17 ft 0 in 0 it 0 in None Exterior 5 10 E 8 Vinyl Double (Clear) Yes 0.38 0.25 16.0 ft2 1 ft 9 in 1 ft 9 in None Exterior 5 11 E 8 Vinyl Double (Clear) Yes 0.38 0.25 16.0 1112 1 It 9 in 1 it 9 in None Exterior 5 12 N 9 Vinyl Double (Clear) Yes 0.38 0.25 8.0 ft2 1 ft 9 in 1 ft 9 in None Exterior 5 13 N 9 Vinyl Double (Clear) Yes 0.38 0.25 32.0 ft2 1 ft 9 in 1 ft 9 in None Exterior 5 14 W 10 Vinyl Double (Clear) Yes 0.38 0.25 16.0 ft2 0 ft 2 in 3 ft 4 in None Exterior 5 15 W 10 Vinyl Double (Clear) Yes 0.38 0.25 32.0 ft2 0 ft 2 in 3 it 4 in None Exterior 5 12/17/2014 5:32 PM EnergyGauge@ USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 110ft2 110ft2 28ft 8ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Best Guess .0005 1942.3 106.63 200.54 .375 9.8363 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF: 8.2 30 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER: 14 30 kBtu/hr 900 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric Tankless Garage 0.92 1 .gal 50 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS V # — Supply — Location R Value Area — Return — Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 1st Floor 6 296.2 It 1st Floor 74.05 ft Default Leakage 1st Floor (Default) (Default). 1 1 12/17/2014 5:32 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6 �0a �0 �0 0 OoO� r-O CDCO CCOCCO 000r- �� CD to CO CO 000 Cn 000 com Ooco coCo Cor- r--r� coco Coco m a°i aai rnCf)U Do co co co co Coco moo r—r rn (a CO COCO »> n �� �� mm Coco E2 m 0 »> 2 inn co mm co co Coco Go co r�r ter` Coco Coco co m m CoCo mm mCo Coco r�r rr. mco Coco d y C7 �rl P,� (Dco (10 CD((DD QQ¢ 00 n (DCDomN 1-� CD Co (O mmm ar w coo coCo CD co (Dco r' hm I-- I- COO CD(D 0 0 LL LL Ii cli fn 22 22 22 22 } U) ¢n. ¢a ¢a ¢a 1O S LU O Ft N W (CO (CO N O H n-» t 0 E CD 12 CTCTIT N O O f0 C n- 0 m ? cri o o a10i af0i US> U)AN U U 2 2 co 0 co a� rn m d 2 IL Pi ui ,It 0 N ti a FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: 10854 SOUTH OCEAN DRIVE #84 PERMIT #: JENSEN BEACH, FL, 34957- MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forcod-air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 12/17/2014 5:32 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 6 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 67 The lower the EnergyPerformance. Index, the more efficient the home. 10854 SOUTH OCEAN DRIVE #84, JENSEN BEACH, FL, 34957- 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows- Description a. U-Factor. Dbl, U=0.38 SHGC: SHGC=0.25 b. U-Factor: N/A SHGC: c. U-Factor. N/A SHGC: d. U-Factor. N/A SHGC: Area Weighted Average Overtiang Depth: Area Weighted Average SHGC: New (From Plans) 9. Wall Types Insulation Area Single-family a. Concrete Block - Int Insul, Exterior R=6.0 1776.00 ft2 b. Frame - Wood, Adjacent R=13.0 112.00 ft2 1 c. N/A R= ft2 2 d. N/A R= ft2 10. Ceiling Types Insulation Area No a. Cathedral/Single Assembly (Unvented) R=1.0 1260.00 1112 1481 b. N/A R= ft2 c. WA R= ft2 Area 11. Ducts R ft2 428.67Area ft2 a. Sup: 1st Floor, Ret: 1st Floor, AH: 1st Floor 6 296.2 ft2 12. Cooling systems kBtu/hr Efficiency ft2 a. Central Unit 30.0 SEER:14.00 8. Floor Types Insulation a. Slab -On -Grade Edge Insulation R=0.0 b. Floor Over Other Space R=19.0 c. N/A R= ft2 13. Heating systems kBtu/hr Efficiency a. Electric Heat Pump 30.0 HSPF:8.20 4.009 ft. 0.250 Area 14. Hot water systems a. Electric Cap: 1 gallons 845.00 ft2 EF: 0.92 636.00 ft2 b. Conservation features ft2 None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code co li feat es. Builder Signature: Date: i00/1-1 Address of New Hom City/FL Zip: ,OV4 f, u ryvs� H� 3 �57 *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software