Loading...
HomeMy WebLinkAboutLetter; EverGuard 60 mil TPO Fleece Back Membrane"Quality You Can. Trust Since 1886... From Technical Services North America's Largest Roofing 1 cara'S Drive Manufacturer" Parsippany, NJ07054 Phone: 1-800-766-3411, option 1 February 4, 2015 J Register Company, Inc. 4640 Sub Chaser Court, Unit 113 Jacksonville, FL 32244 Project: Ted Ferguson 10851 S. Ocean. Dr. 84 Jensen Beach, FL 34957 To Whom It May.Concern,: J Register Company,_ Inc. of Jacksonville,. FL is a GAF Master roofing contractor for asphaltic, single -ply and restoration roofing systems. T-FA-N-N-60FB over Structural Concrete Deck EverGuard® 60 mil TPO Fleece Back Membrane: Install EverGuard® 60 mil TPO fleece back membrane over the concrete deck using rGuard® WB 181 TPO bonding adhesive, at a rate of 0.83 to 1.0 gal/square, applied only to the substrate surface. Side laps shall be minimum 3" wide sealed with minimum 1.5" heat weld. The above listed system will provide up to 600psf of uplift resistance in the field of the roof when installed in accordance with T Trinity E=RD W valuation report # . 01506.09.05 R16 for FL5293 — R15. GAF has provided the above fastening patterns solely as a courtesy and recommends.that the uplift resistance requirements be verified by a design professional. If -you have any further questions, please contact us at 1-800-766-3411, option 1. Thank you for choosing a GAF roofing system. Sincerely, a"C 0 FY ms� 1/uua� Jamie Duvall L h Contractor Services Representative T-FA-N-N-60FB Ted Ferguson Jensen Beach FL 020415 jd rv1 TRINITY ERD ' TABLE 3A: CONCRETE DECKS- NEW CONSTRUCTION OR REROOF(TcRx Orr) SYSTEM TYPE AA BONDED INSULATION, BONDED ROOF COVER System Deck Base Insulation Layer Top Insulation Layer Roof Cover/ Adhesive MDP Type Attach Type Attach No. (See Note 1) Vapor Barrier (Psf) Min. 0.5-Inch EnergyGuard POLYISO Optional additional layers base insulation EverGuard TPO FB Ultra / C-166. Structural None INSULATION, EnergyGuard Ultra, LRF-M followed by min. 0.25-inch Dens Deck Prime or LRF-M GAF 2-Part, spatter -180.0 concrete EnergyGuard RH, EnergyGuard RN SECUROCK Gypsum -Fiber Roof Board Structural Min. 0.25-inch Dens Deck Prime or LRF-M None N/A EverGuard TPO FB Ultra / -195.0 C-167. concrete None SECUROCK Gypsum -Fiber Roof Board GAF 2-Part, spatter C-168. Structural (Optional) See Note A below Min. 0.5-inch EnergyGuard POLYISO GAF 2 Part, CR- (OptionaQ Additional layers base insulation GAF 2 Part, CR- Pa EverGuard TPO FB Ultra / -60.0 concrete INSULATION, EnergyGuard Ultra 20 20 GAF 2-Part, spatter Min. 0.5-inch EnergyGuard POLYISO GAF 2- Optional additional layers base insulation GAF 2- EverGuard TPO FB Ultra / C-169. Structural (Optional) See Note A below INSULATION, EnergyGuard Ultra, Part, CR- followed by min. 0.25-inch Dens Deck Prime or Part, CR- GAF 2-Part, spatter -180.0 concrete EnergyGuard RH, EnergyGuard RN 20 SECUROCK Gypsum -Fiber Roof Board 20 C-170. Structural (Optional] See Note A below Min. 0.25•inch Dens Deck Prime or GAF 2- CR- None N/A and TPO FB Ultra / -195.0 concrete SECUROCK Gypsum -Fiber Roof Board GAF 2-, GAF 2-Part, spatter z0art A. The following are options for installation of an optional vapor barrier / temporary root on the concrete aecK prior to msmanon pracement. rr vapor barrier / temp ruin o vo.aijeb, <1...,.are K p„„-....,.,. Premium Asphalt Primer or ASTM D41 primer prior to its Installation. Maximum design pressure (MDP) shall be the lesser of that for the system in Table 3A, and that for the vapor barrier/ insulation adhesive noted below. 1. For use with OBS00 applied insulation: One or two plies, asphalt -applied GAF base and/or ply sheet: MDP -352.5 psf Ruberoid 20 in Matrix" 102 SBS Membrane Adhesive in full coverage: MDP -202.5 psf Ruberoid Torch Smooth, heat welded: MDP -142.5 psf Ruberoid Heat Weld Smooth, heat welded: MDP -232.5 psf UnderRoof HT High Temperature Leak Barrier, self -adhered: MDP -37.5 psf UnderRoof 2 Polyester -Surfaced Leak Barrier, self -adhered: MDP -127.5 psf 2. For use with CR-20. GAF 2-Part applied insulation: One ortwo plies, asphalt -applied GAF base ply and/or ply. MDP -2615 psf Optional asphalt -applied GAF base ply, ply or base membrane with asphalt -applied GAF cap: MDP -270.0 psf Optional asphalt -applied GAF base ply, ply or base membrane or heat -welded GAF base membrane with heat -welded GAF cap membrane: MDP -169.0 psf Optional self -adhering Liberty base membrane with Liberty cap membrane: MDP -250.0 psf TABLE 3B: CONCRETE DECKS -NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER System No. Deck ' Roof Cover / Adhesive MDP (psf) (See Noteri 7717 Min. 2;50Opsist1uctc0nc. Min. 3,000 psi struct cone. primed with Matra"' 307 Premium Asphalt Primer. EverGuard TPO BUhra(W8181 -300.0 C-172. EverGuard TPO FB Ultra / Hot asphalt -390.0 Exterior Research and Design, LLC d/b/a Trinity I ERD Evaluation Report 01505.09.05-1116 for FL5293-RI5 Certificate ofAuthorization #9503 Revision 16: 08/26/2014 Prepared by Robert Nieminen, PE-59166 Appendix 1, Page 48 of 75