Loading...
HomeMy WebLinkAboutProject InformationLoad Short Form Job: 6121214R - wrightsoft° Date: 12-17-14 Entire House By: EES Inc. FL ?"'roject intormation For: Ferguson Residence 10854 S Ocean. Drive, St Lucie County, FL Design • • Htg Clg Infiltration Outside db (OF) 43 91 Method Simplified Inside db (OF) 70 75 Construction quality Semi -tight Design TD (OF) 27 16 Fireplaces 0 Daily range - L Inside humidity (%) 30 50 Moisture difference (gr/lb) -1 63 HEATING EQUIPMENT COOLING EQUIPMENT Make Rheem Make Rheem Trade RHEEM RPQL SERIES Trade RHEEM RPQL SERIES Model RPQL-030JEZ Cond RPQL-03WEZ AHRI ref 3393231 Coil RHSL-HM3017++RCSL-H*3617 AH R I ref 3393231 Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 21756 Btuh Heating output 28600 Btuh @ 470F Latent cooling 7644 Btuh Temperature rise 27 OF Total cooling 29400 Btuh Actual air flow 980 cfm Actual air flow 980 cfm Air flow factor 0 cfm/Btuh Air flow factor 0.051 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.75 ROOM NAME Area (ftz) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) BED 2 132 0 2006 0 103 BATH 2 77 0 579 0 30 FOYER 70 0 377 0 19 STAIRWELL 71 0 587 0 30 KITCHEN 125 0 1852 0 95 GREAT ROOM 370 0 5050 0 260 HALL 38 0 371 0 19 MASTER BATH 90 0 797 0 41 MASTER BED 228 0 2972 0 153 M WIC 64 0 231 0 12 STAIRS 64 0 714 0 37 SITTING 86 0 2461 0 127 POWDER 42 0 570 0 29 1 AT rhrr%M n) n Af24 n LM V IN L/ R r l Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2014-Dec-17 17:15:53 .► + wrightSOft° Right -Suite® Universal201313.0.08 RSU01062 Page 1 ACCK ...Efficient Energy Job File\6121214R16121214R.rup Calc = MJ8 Front Doorfaces: W Entire House 1481 0 19048 0 980 Other equip loads 0 1074 Equip. @ 1.00 RSM 20122 Latent cooling 6773 TP1TA1 Q 4A44 n 13roor; n aan V IIn 'j, ITV 1 V —VVv v -- Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �. wrightSOW Right -Suite® Universal 2013 13.0.08 RSU01062 /�iCl1 ...Efficient Energy Job File\6121214R\6121214R.1up Calc = MJ8 Front Door faces: W 2014-Dec-17 17:15:53 Page 2 �d- wrightsoft° Component Constructions 61 Date: 12 aR Entire House By: EES Inc. FL Project• • For: Ferguson Residence 10854 S Ocean Drive, St Lucie County, FL Design Conditions Location: Indoor: Heating Cooling Melbourne Regional AP, FL, US Indoor temperature (OF) 70 75 Elevation: 26 ft Design TD ("F) 27 16 Latitude: 28"N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr1lb) -0.6 62.8 Dry bulb (OF) 43 91 Infiltration: Daily range ("F) - 15 (L ) Method Simplified Wet bulb (OF) - 78 Construction quality Semi -tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Cig HTM Gain fP BWhM--°F ft'-'F/Btuh BtuhM Btuh Btuhffl Btuh Walls 13A-6ocs: Blk wall, stucco ext, r-6 ext bd ins, 8" thk, 1/2" gypsum board intfnsh Partitions (none) Windows 4A4-2ob: 2 glazing, heat abs outr, air gas, frill tw brk frm mat, cir low-e innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.25); 50% indoor insect screen; 1.9 ft overhang (3 ft window ht, 1.9 ft sep.) 4A4-2ob: 2 glazing, heat abs outr, air gas, mtl /w brk frm mat, cir low-e innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.25); 50% indoor insect screen; 1.9 ft overhang (6 It window ht, 1.2 ft sep.) 4A4-2ob: 2 glazing, heat abs outr, air gas, mtl /w brk frm mat, cir low-e innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.25); 50% indoor insect screen; 1.9 It overhang (6 ft window ht, 1.9 ft sep.) 106-y: 2 glazing, cir outr, air gas, vnl frm mat, cir innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.48); 9 ft overhang (8 It window ht, 0 ft sep.) 1013-v: 2 glazing, cir outr, air gas, vnl frm mat, cir innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.48); 17 ft overhang (8 ft window ht, 0 It sep.) ID-c2ovd: 2 glazing, cir outr, air gas, vnl frm mat, cir innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.25); 17 It overhang (8 ft window ht, 0 ft sep.) 4A4-2ob: 2 glazing, heat abs outr, air gas, mg /w brk frm mat, clr low-e innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=025); 50% indoor insect screen n 300 0.111 6.0 0 0 1.84 554 e 486 0.111 6.0 0 0 1.84 895 s 266 0.111 6.0 0 0 1.84 491 w 597 0.111 6.0 0 0 1.84 1101 all 1650 0.111 6.0 0 0 1.84 3040 n 9 0.380 0 0 0 10.7 91 e 17 0.380 0 0 0 28.5 485 all 26 0.380 0 0 0 22.6 576 n 34 0.380 0 0 0 10.7 363 e 33 0.380 0 0 0 27.4 891 s 90 0.380 0 0 0 10.7 961 all 157 0.380 0 0 0 14.2 2215 n 34 0.380 0 0 0 10.7 358 e 17 0.380 0 0 0 28.5 485 all 51 0.380 0 0 0 16.7 843 e 24 0.500 0 0 0 14.2 342 s 24 0.500 0 0 0 12.6 302 s 40 0.350 0 0 0 10.8 431 w 119 0.380 0 0 0 28.5 3391 2014-Dec-17 17:15:53 wrightsoft" Right -Suite® Universal 2013 13.0.08 RSU01062 Page 1 fK+C+F1 ...Efficient Energy Job File\6121214R\6121214R.rup Calc = MJ8 Front Door faces: W Doors 11 DO: Door, wd se type a 37 0.390 0 0 0 11.6 428 Ceilings 17A-22xd: Flat ceiling, tar and gravel roof mat, hcd deck, r-22 deck 339 0.039 22.0 0 0 1.30 441 ins, suspended, acoustical int fish, 6" thkns, dead air pinm 17A-22zd: Flat ceiling, membrane roof mat, 140 IMP concrete deck, 636 0.039 22.0 0 0 1.30 825 r-22 deck ins, suspended, acoustical int fish, 8" thkns, dead air pinm Floors 19A-21bstp: Part floor, r-21 ins, frm fir, 6" thkns, dead air pinm, 23 0.045 21.0 0 0 0.57 13 suspended, acoustical int fnsh 22A-cpl: Bg floor, light dry soil, on grade depth, carpet fir fish 118 0.989 0 0 0 0 0 2014-Dec-17 17:15:53 wrightsoft" Right -Suite® Universal 2013 13.0.08 RSU01062 Page 2 .4C(>. ...Efficient Energy Job File16121214RI6121214R.rup Cale = MJ8 Front Door faces: W FL Component Constructions Job: 6121214R wrightsoft p Date: 12-17-14 BED 2 By: EEs Inc. For: Ferguson Residence 10854 S Ocean Drive, St Lucie County, FL Design Conditions Location: Indoor: Heating Cooling Melbourne Regional AP, FL, US Indoor temperature (OF) 70 75 Elevation: 26 ft Design TD (OF) 27 16 Latitude: 280N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) -0.6 62.8 Dry bulb (OF) 43 91 Infiltration: Daily range (OF) - 15 (L ) Method Simplified Wet bulb (OF) - 78 Construction quality Semi -tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain f 2 BIuh&'-'F f 2-°F/Btuh Btuh/W Btuh Btuh/fl' Btuh Walls 13A-6ocs: Blk wall, stucco ext, r-6 ext bd ins, 8" thk, 1/2" gypsum n 79 0.111 6.0 0 0 1.84 145 board int fish w 86 0.111 6.0 0 0 1.84 159 all 165 0.111 6.0 0 0 1.84 304 Partitions (none) Windows 4A4-2ob: 2 glazing, heat abs outr, air gas, mil AN brk frm mat, clr low-e n 34 0.380 0 0 0 10.7 363 innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=025); 50% indoor insect screen; 1.9 it overhang (6 it window ht, 1.2 it sep.) 4A4-2ob: 2 glazing, heat abs outr, air gas, frill /w brk frm mat, cir low-e w 17 0.380 0 0 0 28.5 485 innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.25); 50% indoor insect screen Doors (none) Ceilings (none) Floors 22A-cpl: Bg floor, light dry soil, on grade depth, carpet fir fnsh 23 0.989 0 0 0 0 0 2014-Dec-17 17:15:63 wrightsoft' Right -Suite® Universal 2013 13.0.08 RSU01062 Page 3 Zak ...Efficient Energy Job File16121214R\6121214R.rup Calc = MJ8 Front Door faces: W FL Component Constructions Job: 6121214R Wrlghtsoft p Date: 12-17-14 BATH Z By: EES Inc. Project• • For: Ferguson Residence 10854 S Ocean Drive, St Lucie County, FL Design • • • Location: Indoor: Heating Cooling Melbourne Regional AP, FL, US Indoor temperature ('F) 70 75 Elevation: 26 ft Design TD ('F) 27 16 Latitude: 28'N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) -0.6 62.8 Dry bulb ('F) 43 91 Infiltration: Daily range ('F) - 15 ( L ) Method Simplified Wet bulb ('F) - 78 Construction quality Semi -tight Wnd speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Cig HTM Gain fl' Btuh)W--°F ft'-°F/Bfuh Btuhff Btuh BtuhflN Btuh Walls 13A-6ocs: Blk wall, stucco ext, r-6 ext bd ins, 8" thk, 1/2" gypsum w 81 0.111 6.0 0 0 1.84 149 board int fish Partitions (none) Windows 4A4-2ob: 2 glazing, heat abs outs, air gas, mtl /w brk frm mat, cir low-e w innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.25); 50% indoor insect screen Doors (none) Ceilings (none) Floors 22A cpl: Bg floor, light dry s6il, on grade depth, carpet fir fish 10 0.380 0 0 10 0.989 0 0 0 28.5 0 0 291 0 2014-Dec-17 17:15:53 C + wr!rightsoft' Right -Suite® Universal 2013 13.0.08 RSU01062 Page 4 X& ...Efficient Energy Job File\6121214R\6121214R.rup Cale = MJ8 Front Door faces: W Component Constructions Job: 6121214R - wrightsofto P Date: 12-17-14 FOYER By: EES Inc. FL earoject intormation For: Ferguson Residence 10854 S Ocean Drive, St Lucie County, FL Design Conditions Location: Indoor: Heating Cooling Melbourne Regional AP, FL, US Indoor temperature (OF) 70 75 Elevation: 26 ft Design TD (OF) 27 16 Latitude: 28°N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) -0.6 62.8 Dry bulb (OF) 43 91 Infiltration: Daily range (OF) - 15 (L ) Method Simplified Wet bulb (OF) - 78 Construction quality Semi -tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Walls 13A-6ocs: Blk wall, stucco e)d, r-6 ext bd ins, 8" thk, 1/2" gypsum board int fish Partitions (none) Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' BhrhllP--°F fP-'F/Btuh Btuhflt' Btuh Btuh/ft' Btuh Windows 1013-v: 2 glazing, clr outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/4" e thk; NFRC rated (SHGC=0.48); 9 ft overhang (8 It window ht, 0 ft sep.) Doors (none) Ceilings (none) Floors 22A-cpl: Bg floor, light dry soil, on grade depth, carpet flr fish 20 0.111 6.0 0 0 1.84 37 24 0.500 0 0 0 14.2 342 0.989 2014Dec17 17:15:53 wrightsofte Right -Suite® Universal 2013 13.0.08 R$U01062 Page 5 ACCK ...Efficient Energy Job File\6121214R\6121214R.rup Calc = MJ8 Front Door faces: W FL Component Constructions Job: 6121214R - wrightsoft° p Date: 12-17-14 STAIRWELL By: EES Inc. ��•ect intormation For: Ferguson Residence 10854 S Ocean.Drive, St Lucie County, FL Design Conditions Location: Indoor: Heating Cooling Melbourne Regional AP, FL, US Indoor temperature (OF) 70 75 Elevation: 26 ft Design TD (OF) 27 16 Latitude: 28°N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) -0.6 62.8 Dry bulb (OF) 43 91 Infiltration: Daily range (OF) - 15 ( L ) Method Simplified Wet bulb (OF) - 78 Construction quality Semi -tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions or Area U-value Insul R Htg HTM Loss Cig HTM Gain ft' Btuhff--'F ft'-TOuh RAW Btuh BLOW Bluh Walls 13A-6ocs: Blk wall, stucco ext, r-6 ext bd ins, 8" thk, 1/2" gypsum board intfnsh Partitions (none) Windows (none) Doors 11 DO: Door, wd sc type Ceilings (none) Floors 22A-cpl: Bg floor, light dry soil, on grade depth, carpet fir fish n 47 0.111 6.0 0 0 1.84 87 e 32 0.111 6.0 0 0 1.84 59 all 79 0.111 6.0 0 0 1.84 146 e 37 0.390 0 0 0 11.6 428 12 0.989 0 0 0 0 0 2014-Dec-17 17:15:53 wrightsoft' Right -Suite® Universal 2013 13.0.08 RSU01062 Page 6 ...Efficient Energy Job File\6121214R\6121214R.rup Calc = MJ8 Front Doorfaces: W Component Constructions Job: 6121214R -I�d- wrightsoft° p Date: 12-17-14 KITCHEN By: EES Inc. FL etroject intormation For: Ferguson Residence 10854 S Ocean Drive, St Lucie County, FL Design Conditions Location: Indoor: Heating Cooling Melbourne Regional AP, FL, US Indoor temperature (OF) 70 75 Elevation: 26 ft Design TD (°F) 27 16 Latitude: 28°N Relative humidity (%) 30 50 Outdoor- Heating Cooling Moisture difference (gr/lb) -0.6 62.8 Dry bulb (°F) 43 91 Infiltration: Daily range (°F) - 15 (L ) Method Simplified Wet bulb (OF) - 78 Construction quality Semi -tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM' Loss Clg HTM Gain fN BluhfiF--°F fF-°Ffi3Wh BtuhHF Btuh MAN Btuh Walls 13A 6ocs: Blk wall, stucco ext, r-6 ext bd ins, 8" thk, 1/2" gypsum w 112 0.111 6.0 board i nt fish Partitions (none) Windows 4A4-2ob: 2 glazing, heat abs outr, air gas, mtl /w brk frm mat, clr low-e w innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.25); 50% indoor insect screen Doors (none) Ceilings 17A-22xd: Flat ceiling, tar and gravel roof mat, hcd deck, r-22 deck ins, suspended, acoustical int fish, 6" thkns, dead air pinm Floors 22A-cpl: Bg floor, light dry soil, on grade depth, carpet fir fnsh 10 0.380 0 43 0.039 22.0 0 0 1.84 206 0 0 28.5 291 0 0 1.30 56 13 0.989 0 0 0 0 0 2014-Dec-17 17:15:53 t' wrightsofta Right -Suite® Universal 2013 13.0.08 RSU01062 Page 7 ...Efficient Energy Job File16121214R\6121214R.tup Calc = MJ8 Front Door faces: W FL - wrightsoft Component Constructions Job: 6121214R p Date: 12-17-14 GREAT ROOM By: EES Inc. For: Ferguson Residence 10854 S Ocean Drive, St Lucie County, FL Design Conditions Location: Indoor: Heating Cooling Melbourne Regional AP, FL, US Indoor temperature (°F) 70 75 Elevation: 26 ft Design TD (°F) 27 16 Latitude: 28"N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) -0.6 62.8 Dry bulb (°F) 43 91 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb (OF) - 78 Construction quality Semi -tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions or Area U-value Insul R Htg HTM Loss Clg HTM Gain fF Bluh/tt'-°F fF-°F/BWh Btuh&2 Bhrh BWhM2 Btuh Walls 13A-6ocs: Blk wall, stucco ext, r-6 ext bd ins, 8" thk, 112" gypsum board int fish Partitions (none) Windows e 174 0.111 6.0 0 0 1.84 321 s 114 0.111 6.0 0 0 1.84 209 w 74 0.111 6.0 0 0 1.84 136 all 362 0.111 6.0 0 0 1.84 667 4A4-2ob: 2 glazing, heat abs outr, air gas, mtl /w brk frm mat, clr low-e a 33 0.380 0 0 0 27.4 891 innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.25); 50% indoor insect s 90 0.380 0 0 0 10.7 961 screen; 1.9 It overhang (6 It window ht, 1.2 ft sep.) all 123 0.380 0 0 0 15.1 1852 4A4-2ob: 2 glazing, heat abs outr; air gas, mtl /w brk frm mat, clr low-e w 33 0.380 0 0 0 28.5 927 innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.25); 50% indoor insect screen Doors (none) Ceilings 17A-22xd: Flat ceiling, tar and gravel roof mat, hcd deck, r-22 deck 296 0.039 22.0 0 0 1.30 385 ins, suspended, acoustical int fnsh, 6" thkns, dead air pinm Floors 22A-cpl: Bg floor, light dry soil, on grade depth, carpet fir fish 55 0.989 0 0 0 0 0 2014-Dec-17 17:15:53 wrightsoft" Right -Suite® Universal 2013 13.0.08 RSUD1062 Page 8 AI.I+P� ...Efficient Energy Job File16121214R\6121214R.rup Calc = MJ8 Front Doorfaces: W - wrightsoft° Component Constructions MASTER BATH FL •ject intormation For: Ferguson Residence 10854 S Ocean Drive, St Lucie County, FL Job: 6121214R Date: 12-17-14 By: EES Inc. Location: Indoor: Heating Cooling Melbourne Regional AP, FL, US Indoor temperature (OF) 70 75 Elevation: 26 ft Design TD ('F) 27 16 Latitude: 28'N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) -0.6 62.8 Dry bulb (OF) 43 91 Infiltration: Daily range (OF) - 15 ( L ) Method Simplified Wet bulb (OF) - 78 Construction quality Semi -tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain fP Btuh/W-°F fF-°FBWh BtuhM Btuh BWhMP BWh Walls 13A-6ocs: Blk wall, stucco ext, r-6 ext bd ins, 8" thk, 1/2" gypsum n 88 0.111 6.0 0 0 1.84 162 board int fish a 85 0.111 6.0 0 0 1.84 156 all 173 0.111 6.0 0 0 1.84 319 Partitions (none) Windows 4A4-2ob: 2 glazing, heat abs outr, air gas, mtl /w brk firm mat, clr low-e n 9 0.380 0 0 0 10.7 91 innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.25); 50% indoor insect e 9 0.380 0 0 0 28.5 242 screen; 1.9 ft overhang (3 It window ht, 1.9 ft sep.) all 17 0.380 0 0 0 19.6 333 Doors (none) Ceilings 17A-22zd: Flat ceiling, membrane roof mat, 140 lb/ft' concrete deck, 90 0.039 22.0 0 0 1:30 117 r-22 deck ins, suspended, acoustical int fnsh, 8" thkns, dead air pinm Floors (none) 2014-Dec-17 17:15:53 wrightsoft' Right -Suite® Universal 2013 13.0.08 RSU01062 Page 9 -4C(>% ...Efficient Energy Job File%6121214R16121214R.rup Calc = MJ8 Front Door faces: W Component Constructions Job: 6121214R -�d- wrightsoft° p Date: 12-17-14 MASTER BED By: EEs Inc. FL et'roject intormation For: Ferguson Residence 10854 S Ocean Drive, St Lucie County, FL Design Conditions Location: Indoor: Heating Cooling Melbourne Regional AP, FL, US Indoor temperature (°F) 70 75 Elevation: 26 ft Design TD (°F) 27 16 Latitude: 28°N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) -0.6 62.8 Dry bulb (°F) 43 91 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb (°F) - 78 Construction quality Semi -tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions or Area u-value Insul R Htg HTM Loss Clg HTM Gain ftT BtuhlW--°F W-TBtuh BMW Btuh Btuh/W Btuh Walls 13A-6ocs: Blk wall, stucco md, r-6 ext bd ins, 8" thk, 1/2" gypsum board int fish Partitions (none) Windows 4A4-2ob: 2 glazing, heat abs outr, air gas, mg /w brk firm mat, cir low-e innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.25); 50% indoor insect screen; 1.9 ft overhang (6 ft window ht, 1.9 ft sep.) 4A4-2ob: 2 glazing, heat abs outr, air gas, mil /w brk frm mat, clr low-e innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.25); 50% indoor insect screen Doors (none) Ceilings 17A-22zd: Flat ceiling, membrane roof mat, 140 IMP concrete deck, r-22 deck ins, suspended, acoustical int fish, 8" thkns, dead air pinm Floors (none) n 87 0.111 6.0 0 0 1.84 159 w 174 0.111 6.0 0 0 1.84 320 all 260 0.111 6.0 0 0 1.84 479 n 34 0.380 0 0 0 10.7 358 w 17 0.380 0 0 0 28.5 471 228 0.039 22.0 0 0 1.30 296 2014Dec-Dec17:15:53 wrightsofta Right -Suite® Universal 2013 13.0.08 RSU01062 Page 10 ACM ...Efficient Energy Job File16121214R\6121214R.rup Calc = MJ8 Front Doorfaces: W Component Constructions Job: 6121214R -�- wrightsoft° p Date: 12-17-14 M WIC By: EES Inc. FL For: Ferguson Residence 10854 S Ocean Drive, St Lucie County, FL Design Conditions Location: Indoor: Heating Cooling Melbourne Regional AP, FL, US Indoor temperature (OF) 70 75 Elevation: 26 ft Design TD (OF) 27 16 Latitude: 28°N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) -0.6 62.8 Dry bulb (OF) 43 91 Infiltration: Daily range (OF) - 15 (L ) Method Simplified Wet bulb (OF) - 78 Construction quality Semi -tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTIVI Loss Cig HTM Gain W BtuhflF--°F f!'-°FBtuh Btuh& Btuh Btuh& Btuh Walls 13A-6ocs: Blk wall, stucco ext, r-6 ext bd ins, 8" thk, 1/2" gypsum board int fish Partitions (none) Windows (none) Doors (none) Ceilings 17A-22zd: Flat ceiling, membrane roof mat, 140 Ib/ft3 concrete deck, r-22 deck ins, suspended, acoustical int fish, 8" thkns, dead air pinm Floors 19A 2lbstp: Part floor, r-21 ins, firm fir, 6" thkns, dead air pinm, suspended, acoustical int fnsh e 67 0.111 6.0 0 0 1.84 123 64 0.039 22.0 0 0 1.30 84 23 0.045 21.0 0 0 0.57 13 2014-Dec-17 17:15:53 wrightsofta Right -Suite® Universal 2013 13.0.08 RSU01062 Page 11 /QCM ...Efficient Energy Job File\6121214R16121214R.rup Cale = MJB Front Door faces: W Component Constructions Job: 6121214R -�- wrightsoft° p Date: 12-17-14 STAIRS By: EES Inc. FL •iect intormation For: Ferguson Residence 10854 S Ocean Drive, St Lucie County, FL Design • • • Location: Indoor: Heating Cooling Melbourne Regional AP, FL, US Indoor temperature (OF) 70 75 Elevation: 26 ft Design TD (OF) 27 16 Latitude: 28'N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) -0.6 62.8 Dry bulb (OF) 43 91 Infiltration: Daily range (OF) - 15 ( L ) Method Simplified Wet bulb (OF) - 78 Construction quality Semi -tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain fN Btuh&-°F fF-°Ffi3Wh Btuh& Btuh Btuh/W Btuh Walls 13A 6ocs: Blk wall, stucco ext, r-6 ed bd ins, 8" thk, 1/2" gypsum a 50 0.111 6.0 board 1nt fish Partitions (none) Windows 4A4-2ob: 2 glazing, heat abs outr, air gas, mtl /w brk frm mat, cir low-e e innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.25); 50% indoor insect screen; 1.9 ft overhang (6 ft window ht, 1.9 ft sep.) Doors (none) Ceilings 17A-22zd: Flat ceiling, membrane roof mat, 140 IbIW concrete deck, r-22 deck ins, suspended, acoustical int fnsh, 8" thkns, dead air pinm Floors (none) 17 0.380 0 64 0.039 22.0 0 0 1.84 92 0 0 28.5 485 0 0 1.30 84 2014-Dec-17 17:15:53 �.� wrightsoft@ Right -Suite® Universal 2013 13.0.08 RSU01062 Page 12 i9C�l.P� ...Efficient Energy Job File16121214R16121214R.rup Calc = MJ8 Front Doorfaces: W - wrightsoftComponent Constructions Job: 6121214R P Date: 12-17-14 SITTING By: EES Inc. FL Project Information For: Ferguson Residence 10854 S Ocean Drive, St Lucie County, FL Location: Melbourne Regional AP, FL, US Elevation: 26 ft Latitude: 28 °N Outdoor: Heating Dry bulb (OF) 43 Daily range (OF) - Wet bulb (OF) - Wind speed (mph) 15.0 Indoor: Indoor temperature (OF) Design TD (OF) Relative humidity (%) Cooling Moisture difference (gr/lb) 91 Infiltration: 15 (L ) Method 78 Construction quality 7.5 Fireplaces Heating Cooling 70 75 27 16 30 50 -0.6 62.8 Simplified Semi -tight 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' BIuh/W--°F ft'-'F/Btuh fthNt' Btuh RO N Btuh Walls 13A-6ocs: Blk wall, stucco ext, r-6 e)t bd ins, 8" thk, 1/2" gypsum s 43 0.111 6.0 0 0 1.84 80 board int fish w 71 0.111 6.0 0 0 1.84 131 all 114 0.111 6.0 0 0 1.84 210 Partitions (none) Windows 1D-c2ovd: 2 glazing, cir outr, air gas, vnl frm mat, cir innr, 1/4" gap, s 40 0.350 0 0 0 10.8 431 1/4" thk; NFRC rated (SHGC=0.25); 17 ft overhang (8 ft window ht, Off sep.) 4A4-2ob: 2 glazing, heat abs outr, air gas, mtl /w brk frm mat, cir low-e w 33 0.380 0 0 0 28.5 927 innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.25); 50% indoor insect screen Doors (none) Ceilings 17A-22zd: Flat ceiling, membrane roof mat, 140 Ib/ft concrete deck, 86 0.039 22.0 0 0 1.30 112 r-22 deck ins, suspended, acoustical int fish, 8" thkns, dead air pinm Floors (none) 2014-Dec-17 17:15:53 wrightsoft" Right -Suite® Universal 2013 13.0.08 RSU01062 Page 13 AM ...Efficient Energy Job File%6121214R%6121214R.rup Calc = MJ8 Front Door faces: W FL Component Constructions Job: 6121214R 1- wrightsoft° �" Date: 12-17-14 POWDER By: EEs Inc. Project• • For: Ferguson Residence 10854 S Ocean Drive, St Lucie County, FL Location: Melbourne Regional AP, FL, US Elevation: 26 ft Latitude: 28'N Outdoor: Heating Dry bulb (OF) 43 Daily range (OF) - Wet bulb (OF) - Wnd speed (mph) 15.0 Indoor: Indoor temperature (OF) Design TD (OF) Relative humidity (%) Cooling Moisture difference (gr/lb) 91 Infiltration: 15 (L ) Method 78 Construction quality 7.6 Fireplaces Heating Cooling 70 75 27 16 30 50 -0.6 62.8 Simplified Semi -tight 0 Construction descriptions or Area. u-value Insul R Htg HTM Loss Clg HTM Gain 112 atuh/fl'--°F W-°F/Btuh BLOW Btuh BtuhN Btuh Walls 13A-6ocs: Blk wall, stucco e)t, r-6 ext bd ins, 8" thk, 1/2" gypsum a 58 0.111 6.0 0 0 1.84 107 board int fish s 63 0.111 6.0 0 0. 1.84 117 all 122 0.111 6.0 0 0 1.84 224 Partitions (none) Windows 4A4-2ob: 2 glazing, heat abs outr, air gas, mill AN brk frm.mat, cir low-e e innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.25); 50% indoor insect screen; 1.9 ft overhang (3 ft window ht, 1.9 ft sep.) Doors (none) Ceilings 17A-22zd: Flat ceiling, membrane roof mat, 140IMP concrete deck, r-22 deck ins, suspended, acoustical int fnsh, 8" thkns, dead air pinm Floors (none) 9 0.380 0 42 0.039 22.0 0 0 28.5 242 0 0 1.30 55 2014-Dec-17 17:15:53 �.� wrightsoflt° Right -Suite® Universal 2013 13.0.08 RSU01052 Page 14 ACM ...Efficient Energy Job File\6121214R\6121214R.rup Calc = MJ8 Front Door faces: W Component Constructions Job: 6121214R -�- wrightsof r p Date: 12-17-14 LAUNDRY By: EES Inc. FL •ject intormation For: Ferguson Residence 10854 S Ocean Drive, St Lucie County, FL Design Conditions Location: Indoor: Heating Cooling Melbourne Regional AP, FL, US Indoor temperature (OF) 70 75 Elevation: 26 ft Design TD (OF) 27 16 Latitude: 28°N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) -0.6 62.8 Dry bulb (OF) 43 91 Infiltration: Daily range (OF) - 15 ( L ) Method Simplified Wet bulb (OF) - 78 Construction quality Semi -tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss CIg HTM Gain ft' BIuhiW--°F fl'-"F/Btuh Btuh/ft' Btuh Btuhff Btuh Walls 13A-6ocs: Blk wall, stucco ext, r-6 ext bd ins, 8" thk, 1/2" gypsum board int fish Partitions (none) Windows (none) Doors (none) Ceilings 17A-22zd: Flat ceiling, membrane roof mat, 140 Ib/fts concrete deck, r-22 deck ins, suspended, acoustical Int fnsh, 8" thkns, dead air pinm Floors (none) 33 0.111 6.0 22 0.039 22.0 1.84 1.30 61 29 2014-Dec-17 17:15:53 At. * wrightSoft" Right -Suite® Universal 2013 13.0.08 RSU01062 Page 15 ...Efficient Energy Job Fi[e16121214R16121214R.rup Calc = MJ8 Front Door faces: W 2- -Com onent Constructions Job: 1 -�d- wrightsoft° p Date: 12-17-1414 HALL By: EES Inc. FL rroject intormation For: Ferguson Residence 10854 S Ocean Drive, St Lucie County, FL Design Conditions Location: Indoor: Heating Cooling Melbourne Regional AP, FL, US Indoor temperature (OF) 70 75 Elevation: 26 ft Design TD (OF) 27 16 Latitude: 28°N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) -0.6 62.8 Dry bulb (OF) 43 91 Infiltration: Daily range (OF) - 15 (L ) Method Simplified Wet bulb (OF) - 78 Construction quality Semi -tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' BtuhBt'--°F fl'-°F/Btuh Btuh/ft' Btuh MON stub Walls 13A-6ocs: Blk wall, stucco ext, r-6 ext bd ins, 8" thk, 1/2" gypsum board int fnsh Partitions (none) Windows 1013-v: 2 glazing, cir outr, air gas, vnl firm mat, clr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.48); 17 ft overhang (8 ft window ht, 0 It sep.) Doors (none) Ceilings 17A-22zd: Flat ceiling, membrane roof mat, 140 IMP concrete deck, r-22 deck ins, suspended, acoustical int fnsh, 8" thkns, dead air pinm Floors (none) 13 0.111 6.0 1.84 23 24 0.500 0 0 0 12.6 302 38 0.039 22.0 0 0 1.30 49 2014-Dec-17 17:15:53 ,�+� wrightsoft' Right -Suite® Universal 2013 13.0.08 RSU01062 Page 16 /9l+VP� ...Efficient Energy Job File%6121214R\6121214R.rup Calc = MJ8 Front Doorfaces: W + wrightsoft FL Right-M Worksheet Entire House Job: 6121214R Date: 12-17-14 Yy: EES Inc. 1 Room name Entire House BED 2 2 Exposed wall 219.7 ft 23.0 ft 3 Room height 9.7 ft 9.4 ft cool only 4 Room dimensions 12A x 11.0 ft 5 Room area 1480.9 ft' =0 ft' Ty Construction U-value Or HTM Area (1112) load Area (111 Load number (Btuh/ft'--'F) (Btuhlftj or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 %h13A-6ocs 0.111 n 6.60 1.M 376 300 0 554 113 79 0 145 4A4-2ob 0.380 n 0.00 10.68 9 0 0 91 0 0 0 0 4A4-2ob 0.380 n 0.00 10.68 34 0 0 363 34 0 0 363 4A4-2ob 0.380 _ _n _ 0.00 _ 10.68 34 0 - 0 358 0 0 0 0 11 WH13A-6ocs 0.111 a 0.00 1.84 613 486 0 895 0 0 0 0 1013-v 0.500 a 0.00 14.24 24 22 0 342 0 0 0 0 4A4-2ob 0.380 a 0.00 28.52 17 0 0 485 0 0 0 0 4A4-2ob 0'380 a 0.00 27.40 33 2 0 891 0 0 0 0 4A4-2ob 0.380 a 0.00 28.52 17 0 0 485 0 0 0 0 11DO 0.390 a 0.00 11.62 37 37 0 428 0 0 0 0 'N13A-6ocs 0.111 s 0.00 1.84 420 266 0 491 0 0 0 0 10B-v 0.500 s 0.00 12.57 24 24 0 302 0 0 0 0 ID-c2ovd 0.350 s 0.00 10.77 40 40 0 431 0 0 0 0 ..4A4-2ob 0.380 ,_ s,' O.OQ 10.68 90 90 0 961 0 0 _ 0 0 V�I 13A-6ocs 0.111 w 0.00 1.84 716 597 0 1101 103 86 0 159 L-G 4A4-2ob 0.380 w 0.90 28.52 119 0- 0 3391 17 0 0 485 C _ _ _ 17A-22xd _ 0.039 0.00 _ 1.30 _ 339 339 0 441 0 0 0 0 C 17A-22zd 0.039 - 0.00 1.30 636 636 0 825 0 0 0 0 F 1 OA-21 bstp 0.045 . - 0.00 _ _ 0.57 _ _ 23 23-. 0 13, 0 _ 0 0 0 F 22A-cpl 0.989 - 0.00 0.00 _ 845 118 0 0 132 23 0 0 6 c) AED excursion 0 36 Envelope loss/gain 0 12847 0 1188 12 a) Infiltration 0 662 0 67 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 5 1150 1 230 Appliances/other 4200 500 Subtotal (lines 6 to 13) 10 18859 0 1986 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 18859 0 1986 15 Duct loads 0% 1% 0 189 0% 1% 0 20 Total mom load 0 19048 0 2006 1-1 Air required (cfm) 0 980 10 103 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wriihtsOft" 2014-Dec-1717:15:54 9 Right-Sufte® Universal 2013 13.0.08 RSU01062 page 1 ...Efficient Energy Job File\6121214R18121214R.rup Cale = MJ8 Front Door faces: W + wrightsoft, FL RighW@ Worksheet Entire House Job: 6121214R Date: 12-17-14 By: EES Inc. 1 Room name BATH 2 FOYER 2 Exposed wall 9.7 ft 4.7 ft 3 Room height 9.4 ft cod only 9.4 ft cool only 4 Room dimensions 8.0 x 9.7 ft 1.0 x 69.8 ft 5 Room area 77.3 ft2 69.8 ft2 Ty Construction number U-value (Btuh/ftz °F) Or HTM (Btuh/ft) Area (ftj or perimeter (ft) Load (Btuh) Area (ft� or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cod Gross N/P/S Heat Cool 6 Vh13A-6ocs 4A4-2ob 4A9-2ob 0.111 0.380 0.380 n n n 0.o0 0.00 0.00 1.64 10.68 10.68 o 0 0 6 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 4A4-2ob 0.380 0.111 _ n a 0.00, 0.00 10.68 1.84 _. 0 0 0_ 0 0 0 0, 0 0 44 0 20 0 0 0 37 WH13A-6ocs 1013-v 4A4-2ob 4A4-2ob 4A4-2ob 11DO 0.500 0.380 0.380 0.380 0.390 a a a a a 0.00 0.00 0.00 0.00 0.00 14.24 28.52 27.40 28.52 11.62 0 0 0 0 0 0 0 0 .0 0 0 0 0 0 0 0 0 0 0 0 24 0 0 0 0 22 0 0 0 0 0 0 0 0 0 342 0 0 0 0 106-v 1D-c2ovd 0.111 0.500 0.350 s s s 0.00 0.00 0.00 1.84 12.57 10.77 0 0 0 0 0 0 _ 0 0 0 0- 0 0 0 0 0 0 0 0 0 0 0 0 0 0 N13A-6ocs. W C 4A4-2ob. 13A-6ocs 4A4-2ob 17A-22xd 0.380 0.111 0.380 0.039 s w w _ - 0.00 0.00 0.00 0.00 10.68 1.84 _ . _ 28.52 _ 1.30 0 91 , ,_ _ 10 0 0 81 _ . 0 0, 0 0 0 0 0 149 291 _ 0. 0 0 0 0 0 0 0 0 Q 0 _0 0 0 0 0 0 C . 17A-22zd 0.039 0.00 1.30 0 0 0 0 0 0 0 0 F 19A 2lbstp 6.045 - 0.00 ._ 0.57 0 0 0 0 6 0 0 0 F 22A-cpl 0.989 - .0.00- _ 0.00 77 10 0 _ 0 70 5 0 0 6 c) AED excursion 105 -19 Envelope loss/gain 0 545 0 360 12 a) Infiltration 0 28 0 14 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 0 573 0 373 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 573 0 373 15 Duct loads 0% 1% 0 6 0% 1% 0 4 Total room load 0 579 0 377 Air required (cfm) 0 30 01 19 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsoft" 2014-Dec-1717:15:54 ��9 Right -Suite@ Universal 2013 13.0.08 RSU01062 Page 2 ..Efficient Energy Job File16121214R16121214R.rup Cale = MJ8 Front Door faces: W ei o >+ � G m O s cn 000000000000o0c8—$000 v 2 80 0g 9 oo0r,,,�m 98 •NN N N or3 r C Q U $O M L U Z N w X 2 OR x F-C'S ,0000000000 000 ON ogo0 0v - c o CL 0ooao000000000�ora0O'n O o m N t�000O)00000000000.000f�0 00 OOOfO� 0 0 0 0 0 0 0 0 0 0 0 0 0 0,0 0 0 0,0 O O 00 O 00000 cc M w '� Q' M x 2 r to o a c�0000�0000�000000000n ts CD ICoo 881AN lQpNptD9D,)rzSo9�jMc'D00 8888888888i88888a8'888 7q ,O C O C 00 CO C O'C O 000000'00 2 p, N 0) N N w 3 CCpp °L ppCpp ppCp pp4) pp4) pGCD CN Op0) p3p �eO}� O�� ;C7M9 §99 fh l00 �1f1� 007 �r:go 9,'OOMi O G O C d d C C d 6 C C G C O C'C C O O �m oa �S$$$$$$0 o$ API co $ C Uc A NY CO rovagv�c�ro��n�27 w�aa in��'no' s'¢ co (D N r 0 U Q m w 00 0 cn m Q LL O O O * wrightsoft' FL Right-M Worksheet Entire House Job: 6121214R Date: 12-17-14 By: EES Inc. 1 Room name GREAT ROOM HALL 2 Exposed wall 55.0 ft 3.7 ft 3 Room height 9.4 ft cool only 10.0 ft cool only 4 Room dimensions 1.0 x 370.0 ft 3.7 x 10.3 ft 5 Room area 370.0 ft2 37.9 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft? "F) (Btuh/ftj or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�;J G 13A Gbcs . 4A4-2ob 4A4-2ob 0.111 0.380 0.380 . n n n 0:00 0.00 0.00 1.84 1068 10.68 0 0 0 0 0 0 0 0 0' _ 0 0 0 0 % 0 0 0 0 0, 0 0 0 0 - 0 G 4A4-2ob .6.380 _ n-- , 0.00 _..16.68 ._ _ .0 _ ._ 0 :,. - 0 ._ _0 , _ 0 0 . - ._ __0 0 WH13A-6ocs 11 0.111 a 0,00 1.84 207 174 0 321 0 0 0 0 10B-v 0,500 a 0.00 14.24 0 0 0 0 0 0 0 0 4A4-2ob - 0.380 a 0.00 28.52 0 0 0 0 0 0 0 0 4A4-2ob 0.380 a 0,00 27.40 33 2 0 891 0 0 0 0 4A4-2ob 0.380 a 0.00 28.52 0 0 0 0 0 0 0 0 11DO 0,390 a 0.00 11.62 0 0 0 0 0 0 0 0 13A-6acs 0.111 s 600 1:84 204 114 0 209 37 13 0 23 10B v 0.500, s 0.00 1257 0 - 0 0 0 24 24 , 0 .302 1D 2ovd' 0,350 s 0.00 10.77 ,0 0 0 0 0 0, 0 0 4A4-2ob - 0.380 - 's. 0.00 _ _10.68 _ _190 „ 90 - _ ._- .. 0 -. 961 0 0 0 . - 0 W 13A-6ocs 0.111 w 0.00 1.84 107 74 0 136 0 0 0 0 4A4-2ob 0.380., w_- 0.00 28.52 33 U 0 927 0 0 - 0 0 C.. - - -- 17A-22xd _ ... . __. 0.039 - _- _ - _ ._0.00 - - - 1.30 _- 296 _ .., . 296 -- 0 .__ _. - ._ ; - 385 . _ _.- - . _ : 0 -.. - - _.. _ 0 . 0 - - - 0 C 17A-2wd 0.039 - 0.00 1.30 0 0 0 0 38 38 0 49 F _ -19A-21bstp- 0.045 _ . -_ 0.00 _ 0.67 0 0 _0 .. -- 0 = 0 0 .. 0. .. . _ 0 F -- _ 22A-cpl --.. 0.989 _ - 0,00 - 0-00 _ . _ 370 _55 - 0_ _0 - -0, _ . ,. 0_ 0, 0 6 c) AED excursion 251 -18 Envelope loss/gain 0 3579 0 356 12 a) Infiltration 0 161 0 11 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 800 0 Subtotal (lines 6 to 13) 0 50M 0 367 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 5000 0 367 15 Duct loads 0% 1% 0 50 0% 1% 0 4 Total room load 0 5050 0 371 Air required (cfm) 0 260 0 19 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. L wri htsc)o t- 2014-Dec-1717:15:54 �.�� 9 Right -Suite® Universal 2013 13.0.08 RSU01062 Page 4 ...Efficient Energy Job File16121214R16121214R.rup Calc = MJ8 Front Doorfaces: W + wrightsoft, FL Right-J® Worksheet Entire House Job: 6121214R Date: 12-17-14 By: EES Inc. 1 Room name MASTER BATH MASTER BED 2 3 Exposed wall Room height 10.0 ft 19.0 ft cool only 31.0 ft 10.0 ft cool only 4 5 Room dimensions Room area 9.7 x 9.3 ft 90.2 W 12.0 x 19.0 ft 228.0 ft2 Ty Constriction number U-value (Btuh/ft? °F) Or HTM (Btuh/ft2) Area (ft5 or perimeter (ft) Load (Btuh) Area (ftj or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 A4-2ocs 4A4-lob 4A4-2ob 4A4-2ob 1013-v 4A4-2ob 4A4-2ob 4A4-2ob 11DO 13A-6ocs 1013-v 1Dc2ovd 4A4-2ob. 13A-6ocs 4A4-2ob 17A-22xd . 17A-22zd 0.181 0.380 0.380 0.380 0.111 0.500 0.380 0.380 0.380 0.390 0.111 0.500 0.350 0.380 0.111 0.380 0.039 0.039 n n n n a a a a a a s s s s, . w w - - 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 _ __0.00 0.00 0.00 10.68 0.68 10.68 16.68 1.84 14.24 28.52 27.40 28.52 11.62 - 1.84 12.57 10.77 10.68 1.84 _28.52 _ .1.30 1.30 97 9 0 _ _ 0 93 0 9 0 0 0 0 0 0 0 0 0 0 90 B0 0 0 .0- 85 0 0 0 0 0 0 0 0 0 0 0 0 90 0 � 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 91 191 0 0 156 0 242 0 0 0 0 0 0 0 0 0 0 117 120 0 0 34 0 0 0 0 0 __0 0 0 0 0 190 17 0 228 87 0 0 0 0 0 0 0 0 _ 0 0 0 0 0 174 _ 0- .. 0 228 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 150 0 0 358 0 0 0 0 0 0 0 0 0 0 320 471 0 296 WH13A-6ocs G -- W C C F F 19A-2lbstp 22A-cpl .0.045 0.989 - - _ 0.00 0.00 0.57 - 0.00 0 0 0 0 0. 0 0.. 0 0 0- 0 0 0 0 0 0 6 c) AED excursion -40 -17 Envelope loss/gain 0 730 0 1586 12 a) Infiltration 0 59 0 97 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliancestother 0 800 Subtotal Qines 6 to 13) 0 789 0 2943 Less external load 0 0 0 0 Less transfer 0 0 0 0 14 Redistribution Subtotal 0 0 0 789 0 0 0 2943 15 Duct loads 0% 1% 0 8 0% 1% 0 29 Total room load Air required (cfm) 0 0 7971 41 0 0 2972 153 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. •- wri f,ttlsoft" 2014-Dec-17 17:15:54 TI g Right -Suite® Universal 2013 13.0.08 RSU01062 Page 5 ti ..Efficient Energy Job Flle16121214R16121214R.rup Calc = MJ8 Front Door faces: W -!'!d- wrightsoft FL Right-M Worksheet Entire House Job: 6121214R Date: 12-17-14 By: EES Inc. 1 Room name M WIC STAIRS 2 Exposed wall 6.7 ft 6.7 ft 3 Roan height 10.0 ft cool only 10.0 ft cool only 4 Room dimensions 9.7 x 6.7 It 9.7 x 6.7 it 5 Room area 64.4 ft2 64.4 ftz Ty Construction number U-value (Btuh/ft? °F) Or HTM (Btuh/ft2) Area (ft� or perimeter (ft) Load (Btuh) Area (ft5 or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cod 6 A4-lobs 4A42ab 4A4-2ob 0.111 0.380 0.380 n n n 0.00 0.00 0.00 1.68 10.68 10.68 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 4A4.2ob 13A-6ocs 0.380, 0.111 n. a 0.00 0.00 10.68 1.84 0 67 0 67 0 0 0 123 0 67 0 50 0 0 0 92 W 10B-v 4A4-2ob 4A4-20b 4A4-2ob 11DO 0.500 0.380 0.380 0.380 0.390 a a a a a 0.00 0.00 0.00 0.00 0.00 14.24 28.52 27.40 28.52 11.62 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 17 0 0 0 0 0 0 0 0 0 0 0 0 0 0 485 0 1 1OB-v 06-v 1 D-c2ovd 0. 0.500 0.350 s s s 0.00 0.00 0.00 1.84 12.57 10.77 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4A4-2ob 13A-6ocs 0.380 0.111 s w 0.00. 0.00 10.68 1.84 0 0 0 0 0_ 0 0 0 0 0 0 0 0 0 0 0 V,1! -G 4A4-2ob 17A-22xd 0.380 am w_ -_ _0.00 A.00 28.52 1.30 0 _ 0 0 0 0 0 0_ 0,_. 0_ 0 0 0, 0 0 0 0 C C 17A-22zd 0.039 - 0.00 1.30 64 64 0 84 64 _6.4 0 84 F F 19A-21bstp 22A-cpl O045 0.989 _ - - _ _ 0.00 0.00 0.57 _ 0.00 '_ 23 0 23 0 0 0 _ 13 0 0 0 6 0 0 0 0 0 6 c) AED excursion -12 26 Envelope loss/gain 0 208 0 687 12 a) Infiltration 0 21 0 21 b) Room ventilation 0 0 0 0 13 1ntemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 0 229 0 707 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 229 0 707 15 Duct loads 00/0 1% 0 2 00/0 1% 0 7 Total room load 0 231 1 0 714 Air required (cfm) I 1 0 12 10 37 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -- wrightsOTt' 2014-Dec-17 17:15:54 ti Right -Suite® Universal 2013 13.0.08 RSU01062 Page 6 ...Efficient Energy Job File16121214R\6121214R.rup Calc = MJ8 Front Door faces: W M :saoe; joo0 luaxl SrW = oleo dru'atiLZLZL9\214LZLZL9\al!d qor A6iau3 lualoOl3"' r7 L a6ed Z90LOnS21 8o'0'EL £LOZ leSian!un C9L!nS-346!i! o}�OS;y6�JM 4S:9VLL LL-390-Koz 'P3 Mg r lenuew 10 sjuawaimbei lie }aaw of VOOV Aq PeAoidde suoi;epoleo 6Z 0 LZL 0 (wlo) pai!nbar n`d OLS 0 L9bZ 0 Peol uooi IRAL 9 0 %L %0 trz 0 %L %0 speol Lono SL m 0 9£6Z 0 Ie;oAnS 4L 0 0 0 0 uainclpisWP 1 0 0 0 0 ja;smL ssal 0 0 0 0 Pool lewaLxa ssa-1 m 0 9£tZ 0 (£L ol9 sau!l) IeloAnS 0 0 0 009 0 0 j94lo/s9oue!Idd`d 0£Z @ sWWnao0 :su!e6 Im-lul EL 0 06 0 0 0 8S 0 0 uO!lel!Luan woos (q uo!leglgul (e ZL 4Z9 0 9L81, 0 ule6/ssoladolaw3 £ 86L ucI-- O3 V (o 9 0 0 0 0 0 0_ 0 0 0 0- 0 0 0 0 0' 0 00'0 L9,O 00'0 00'0 = -_ 696-0 S60'0 ,- _ Wo-VZZ d3SgLZ=V6L d 3 _ SS 0 0 0 0 -0 0 & - 0 ZV 0 _ D ZLL 0 LZ6 0 0 0 99 0 - _ 0 99 0 _ E£ OE 'L OE'i ZS'8Z 00'0 00'0 00"0 - - M 6£0'0 6E0'O , OS£'O Pzzz-Va PXZZ-VLL g0Z-6Vb O O 0 0 0 0 0 0 0 0 L£L 0 0 0 LL 0 SOL 0 49"L _ 89'01, 00'0 0070 M S LLL'0 09E'0 S309-VEL goZ-tV6 /G1 0 0 aL, 0 0 0 0 0 £9 0 0 £9_ LEV 0 08 0 0 0 06 0 £6 Otb 0 E9_ LL'OL LSzL V91 00'0 00'0 00'Q S S _s OS£'0 009'0 LLL'0_ PA0Z0-0L A-SOL S309-`d£L 0 0 0 0 0 0 _ 6 0 _ _ 0 0 0 0 0 0 0 0 Z9"4 Z9'8Z 00'0 00'0 a a OB£'O 08£'0 OOLL goZ-6Vb 0 ZbZ 0 0 0 0 0 0, 0 0 6 0 0 0 0 0 0 0 0 0 0 0 0 0 Ob'LZ Z9'9Z Irz*K 00'0 00'0 00'0 a a a 098*0 08£'0 009'0 qoZ-6V4 QOZ-4VI' A-SOL LOL 0 0 0 99 0 L9 0 0 0 0 0 0 0 0 _ 0 v8"L 89'OL 00'0 00'0- a u LLL'0 09£'0 soo9-VEL qoZ t o M LL 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0_ 0 0 0_ 0 0 0 0 0 0 99'OL 89'OL 091 _ 00'0 00'0 000 _-- u" u u 08E'0 08£'O LLL"0 goZ-kVti goZ-bVir S009-VEL ' 9 IIV��1 POO MH S/d/N sscr0 1000 3e81-1 S/d/N S=E) IOOO W9H jO (do�ul4nL9) en!en-n jagwnu uo!pruLsuoo Ll (gn39) PWI (u) jeja aped m W) —V (LInIS) Peol (u) jeja aped jo (zu) E-V (zu/gn39) VUH zu azti u L'9 x £'9 /4- IOOO u 0'01, u 0'£L zu L'99 u E'OL x £'9 Rluo loco u 0"01, u L"8L wale woos suo!suaw!p woos ly6lay wco2f 11wM posodx3 S IF E Z a30MOd ONIl11S aweu wc0a L l=1 'oul S33 :A9 b6-L6-Z6 :a;ea asno%/ aa�;u3 unung mor 1804s)iJoM QW-14B21 ,dos;y6fann + + wrightsoft° FL Right-JO Worksheet Entire House Job: 6121214R Date: 12-17-14 By: EES Inc. 1 Room name LAUNDRY 2 Exposed wall 3.3 ft 3 Room height 10.0 ft cool only 4 Roan dimensions 3.3 x 6.7 ft 5 Roan area 222 W Ty Construction number U-value (Btuh/ft;°F) Or HTM (Btuhlft2) Area (ft� or perimeter (ft) Load (Btuh) Area or perimeter Load Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-6ocs 4A4-2ob 4A4-2ob 6.111 0.380 0.380 -n n n 0.00 0.00 0.00 1.84 10.68 10.68 0 0 0. 0 0 0 0 0 0 0 0 0 -G 11 II-CG 4A4-2ob .0.380.-- 0.111 n a 0.00 0.00 10.68 1.84 0 0 0 0 0- 0 0 0 WM13A-6oas 106-v 0.500 a 0.00 14.24 0 0 0 0 4A4-2ob 4A4-2ob 0.380 0.380 a a 0.00 0.00 28.52 27.40 0 0 0 0 0 0 0 0 4A4-2ob 11DO 0.380 0.390 a a 0.00 0.00 28.52 11.62 0 0 0 0 0 0 0 0 VN13A-vacs 10B-v 0.111 0.511 s s 0.00 0.00 1.84 1257 33 0 33 0 0 0 61 0 1D-c2ovd 0.350 s 0.00 10.77 0 0 0 0 4A4.2ob 13A-6ocs 4A42ob 17A-22xd 0.380 0.111 0.380 0.039 s w w_ . - -0.00_ 0.00 0.00 0.00 10.68 1.84 _ _ 28.52 1.30 0 0 0 -.0'. 0 0 0- 0 0 0 0 0 0 0 . - _ 0 _. 0 W C C 17A-22zd 0.039 - 0.00 1.30 22 22 0 29 F 19A-21 bstp 0.045 _ _ - 0.00 0.57 0 0 0 , 0 F 22A-cpi 0.989 , ,- 0 00 _. 0.00 0 0 0 0 6 c) AED excursion -24 Envelope loss/gain 0 66 12 a) Infiltration 0 10 b) Room ventilation 0 0 13 Intemal gains: Occupants @ 230 0 0 Appliancestother 400 Subtotal (lines 6 to 13) 0 477 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 0 477 15 Duct loads 0% 1% 0 5 Total room load 0 481 Air required (cfm) 0 25 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - wrightsoft- 2014-Dec-17 17:15:54 Right -Suite® Universal 2013 13.0.08 RSU01062 Page 8 ...Efficient Energy Job File\6121214R\6121214R.nip Calc = MJ8 Front Door faces: W wrightsofte Manual S Compliance Report Entire House Job: 6121214R Date: 12-17-14 By: EES Inc. j Project Information For: Ferguson Residence 10854 S Ocean Drive, St Lucie County, FL Cooling Equipment Design Conditions Outdoor design DB: 90.8°F Sensible gain: 20122 Btuh Entering coil DB: 76.1°F Outdoor design WB: 78.4°F Latent gain: 6773 Btuh Entering coil WB: 64.0°F Indoor design DB: 75.0'F Total gain: 26895 Btuh Indoor RH: 50% Estimated airflow: 980 cfm Manufacturer's Performance Data at Actual Design Conditions EVVlIquipment type: SplitASHP IMush"A: Rhea cfm Model: RPQL-030JEZ+RHSL-HM3017++RCSL-H*3617 Sensible capacity: 21756 Btuh 108% of load Latent capacity: 7644 Btuh 113% of load Total capacity: 29400 Btuh 109% of load SHR: 74% Heating Equipment Design Conditions design DB: 43.4°F Heat loss: 0 Btuh Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Entering coil DB: 70.0°F Manufacturer: Rheem Model: RPQL-030JEZ+RHSL-HM3017++RCSL-H*3617 Actual airflow: 980 cfm Output capacity: 28600 Btuh 0% of load Capacity balance: -33 OF Supplemental heat required: 0 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: Back Up Model: Actual airflow: 980 cfm Output capacity: 8.0 kW 0% of load Temp. rise: 25 OF The above equipment was selected in accordance with ACCA Manual S. 2014-Dec-17 17:15:55 AL wrightsoftb Right -Suite® Universal 2013 13.0.08 RSU01062 Page 1 X& ...Efficient Energy Job File\6121214R16121214R.rup Calc = MJ8 Front Door faces: W