HomeMy WebLinkAboutCreekside Lot 37-dsUES Project No:
Workorder No:
Report Date:
3360.1800067.0000
227345-1
03/12/2021
607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580
In-Place Density Test Report
Client:D.R. HORTON, INC. EAST FLORIDA DIVISION UES Technician:Johnnie Smith
1430 Culver Drive, NE
Palm Bay, FL 32907
Date Tested:03/08/2021
Project:18-5043.03 CREEKSIDE
Yorktown Drive & Okeechobee Road, Fort Pierce, County, FL
Type of Test:
Area Tested:Lot 37 - 3346 Trinity Circle, Ft. Pierce
Permit # 2011-0165
Field:ASTM D-6938 Nuclear Gauge Method
Material:Fill Laboratory:ASTM D1557 Modified Proctor
Reference Datum:0 = Top of Final Grade
The tests below meet the 95% minimum compaction requirement.
Test
No.Location of Test Range
Maximum
Density
(pcf)
Optimum
Moisture
(%)
Field Dry
Density
(pcf)
Field
Moisture
(%)
Soil
Compaction
(%)
Pass
or
Fail
1 E Section 0-1 ft 118.6 10.8 115.7 10.0 98 Pass
2 W Section 0-1 ft 118.6 10.8 114.8 10.1 97 Pass
3 Center 0-1 ft 118.6 10.8 114.9 10.0 97 Pass
Remarks:Permit # 2011-0165
Reviewed By
GFA International, Inc
Florida Registry Number. 4930
Thomas Dominic Montano
Branch Manager
STATE OF FLORIDA
Professional Engineer No. 84146
To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and
authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval.
Page 1
This item has been digitally signed and sealed
by Thomas Dominic Montano, P.E. on the date
adjacent to the seal. Printed copies of this document
are not considered signed and sealed and the
signature must be verified on any electronic copies.