Loading...
HomeMy WebLinkAboutCreekside Lot 37-dsUES Project No: Workorder No: Report Date: 3360.1800067.0000 227345-1 03/12/2021 607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580 In-Place Density Test Report Client:D.R. HORTON, INC. EAST FLORIDA DIVISION UES Technician:Johnnie Smith 1430 Culver Drive, NE Palm Bay, FL 32907 Date Tested:03/08/2021 Project:18-5043.03 CREEKSIDE Yorktown Drive & Okeechobee Road, Fort Pierce, County, FL Type of Test: Area Tested:Lot 37 - 3346 Trinity Circle, Ft. Pierce Permit # 2011-0165 Field:ASTM D-6938 Nuclear Gauge Method Material:Fill Laboratory:ASTM D1557 Modified Proctor Reference Datum:0 = Top of Final Grade The tests below meet the 95% minimum compaction requirement. Test No.Location of Test Range Maximum Density (pcf) Optimum Moisture (%) Field Dry Density (pcf) Field Moisture (%) Soil Compaction (%) Pass or Fail 1 E Section 0-1 ft 118.6 10.8 115.7 10.0 98 Pass 2 W Section 0-1 ft 118.6 10.8 114.8 10.1 97 Pass 3 Center 0-1 ft 118.6 10.8 114.9 10.0 97 Pass Remarks:Permit # 2011-0165 Reviewed By GFA International, Inc Florida Registry Number. 4930 Thomas Dominic Montano Branch Manager STATE OF FLORIDA Professional Engineer No. 84146 To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. Page 1 This item has been digitally signed and sealed by Thomas Dominic Montano, P.E. on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.