Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Engery Calcs
FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: TATAROWICZ ULTIMATE MAN CAVE Builder Name: JUL ? 1 Street: 6311 OLEANDER AVE. Permit Office: ST. LUCIE COUNTY JVL , City,State,Zip: FT. PIERCE , FL,2 Permit Number: Owner: TATAROWICA Jurisdiction: Ft L iciP +:cunt•, FL Design Location: FL, Fort Pierce County:: ST. LUCIE COUNTY(Florida Climate Zone 2) " 1. New construction or existing New(From Plans) 9. Wall Types(5140.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=9.0 4748.70 ft2 b. Frame-Wood, Exterior R=11.0 392.00 ft2 3. Number of units,if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 0 d. N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (2911.0 sqft.) Insulation Area 2 a. Roof Deck(Unvented) R=20.0 2911.00 ft 6. Conditioned floor area above grade(ft2) 4658 b. N/A R= ft2 Conditioned floor area below grade(ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(362.0 sqft.) Description Area a. Sup:Attic, Ret:Attic,AH: UTILITY 6 475 a. U-Factor: Dbl, U=0.65 225.00 ft2 b. Sup: Attic, Ret:Attic,AH: PARTS LOFT 6 375 SHGC: SHGC=0.25 b. U-Factor: Dbl, U=0.65 96.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a.Central Unit 47.0 SEER:16.50 c. U-Factor: Dbl, U=0.63 41.00 ft2 b.Central Unit 29.4 SEER:16.50 SHGC: SHGC=0.25 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 34.0 COP:1.00 SHGC: b. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 3.282 ft. Area Weighted Average SHGC: 0.263 14. Hot water systems 8. Floor Types (2911.0 sqft.) Insulation Area a. Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 2911.00 ft2 b. Conservation features EF:0.970 b. N/A R= ft2 None c. N/A R= ft2 15.Credits Pstat � Glass/Floor Area: 0.078 Total Proposed Modified Loads: 132.87 PASS Total Baseline Loads: 136.02 1 hereby certify that the plans and specifications covered by Review of the plans and O� THE ST44 this calculation are in compliy nce with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. 1► PREPA B Before construction is completed a DATE: this building will be inspected for 0 y compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. 5� with the Florida Energy Code. COD WE OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. T 7/20/2017 4:01 PM EnergyGauge(D USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2014 PROJECT Title: TATAROWICZ ULTIMATE M Bedrooms: 0 Address Type: Street Address Building Type: User Conditioned Area: 4658 Lot# Owner: TATAROWICA Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 6311 OLEANDER AVE. Permit Office: ST.LUCIE COUNTY Cross Ventilation: No County: ST. LUCIE COUNTY Jurisdiction: Whole House Fan: No City,State,Zip: FT. PIERCE, Family Type: Single-family FL, 2 New/Existing: New(From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 AHU 1 3068 28839.2 2 AHU 2 1590 22306 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 TROPHY ROOM 168 1579.2 No 0 1 No Yes Yes 2 REF. LOUNGE 330 3102 No 4 1 No Yes Yes 3 WORKSHOP 671 6307.4 No 0 1 No Yes Yes 4 RESTROOM 35 329 No 0 1 No Yes Yes 5 STAIR 76 714.4 No 0 1 No Yes Yes 6 PARTS LOFT 376 3534.4 No 0 1 No Yes Yes 7 ELECTRICAL PAR 216 2030.4 No 0 1 No Yes Yes 8 OFFICE 121 1137.4 No 0 1 No Yes Yes 9 UPHOLSTERY 206 1936.4 No 0 1 No Yes Yes 10 WIC 36 338.4 No 0 1 No Yes Yes • 11 BATH 98 921.2 No 0 1 No Yes Yes 12 UTILITY 62 582.8 No 0 1 No Yes Yes 13 BATH 2 80 752 No 0 1 No Yes Yes 14 HALL 95 893 No 0 1 No Yes Yes 15 GAME ROOM 498 4681.2 No 4 1 No Yes Yes 16 GARAG 920 16008 No 4 1 No Yes Yes 17 GAR 670 6298 No 0 1 No Yes Yes 7/20/2017 4:01 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio TROPHY ROOM 27 ft 0 168 ft2 ---- 0 1 0 2 Slab-On-Grade Edge Insulatio REF. LOUNGE 20 ft 0 330 ft2 ---- 0 1 0 3 Slab-On-Grade Edge Insulatio WORKSHOP 54.9 ft 0 671 ft2 ---- 0 1 0 4 Slab-On-Grade Edge Insulatio RESTROOM 1 ft 0 35 ft2 ---- 0 1 0 5 Slab-On-Grade Edge Insulatio STAIR 8 ft 0 76 ft2 ---- 0 1 0 6 Slab-On-Grade Edge Insulatio PARTS LOFT 8.4 ft 0 41 ft2 ---- 0 1 0 7 Slab-On-Grade Edge Insulatio GARAG 76 ft 0 920 ft2 ---- 0 1 0 8 Slab-On-Grade Edge Insulatio GAR 52 ft 0 670 ft2 ---- 0 1 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch v # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 3068 ft2 0 ft2 Medium 0.6 No 0.9 No 20 18.4 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Unvented 0 2911 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Unvented) TROPHY ROOM 20 Blown 51 ft2 0.1 Wood 2 Under Attic(Unvented) WORKSHOP 20 Blown 128 ft2 0.1 Wood 3 Under Attic(Unvented) STAIR 20 Blown 4 ft2 0.1 Wood 4 Under Attic(Unvented) PARTS LOFT 20 Blown 376 ft2 0.1 Wood 5 Under Attic(Unvented) ELECTRICAL PA 20 Blown 216 ft2 0.1 Wood 6 Under Attic(Unvented) OFFICE 20 Blown 121 ft2 0.1 Wood 7 Under Attic(Unvented) UPHOLSTERY 20 Blown 206 ft2 0.1 Wood 8 Under Attic(Unvented) WIC 20 Blown 36 ft2 0.1 Wood 9 Under Attic(Unvented) BATH 20 Blown 98 ft2 0.1 Wood 10 Under Attic(Unvented) UTILITY 20 Blown 62 ft2 0.1 Wood 11 Under Attic(Unvented) BATH 2 20 Blown 80 ft2 0.1 Wood 12 Under Attic(Unvented) HALL 20 Blown 95 ft2 0.1 Wood 13 Under Attic(Unvented) GAME ROOM 20 Blown 498 ft2 0.1 Wood 14 Under Attic(Unvented) GARAG 20 Blown 920 ft2 0.1 Wood 15 Under Attic(Unvented) GAR 20 Blown 20 ft2 0.1 Wood 7/20/2017 4:01 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2014 WALLS Adjacent SOrnt To Wall Tvpepace Cavity Width Height Sheathing Framing Solar Below R_V le Ft In Et In Area R-Vallle Frarfinn AhSor rrqtle% 1 N Exterior Concrete Block-Int InsIFROPHY RO 9 1 0 9 4 9.3 ft2 0 0 0.6 0 2 S Exterior Concrete Block-Int Ins!FROPHY RO 9 14 0 9 4 130.7 ft2 0 0 0.6 0 3 W Exterior Concrete Block-Int InsJROPHY RO 9 12 0 9 4 112.0 ft2 0 0 0.6 0 4 W Exterior Concrete Block-Int InsREF. LOUNG 9 20 0 9 4 186.7 ft2 0 0 0.6 0 5 N Exterior Concrete Block-Int InWORK SHOP 9 1 0 9 4 9.3 ft2 0 0 0.6 0 6 E Exterior Concrete Block-Int Ins)WORK SHOP 9 23 0 9 4 214.7 ft2 0 0 0.6 0 7 S Exterior Concrete Block-Int InsVORK SHOP 9 31 0 9 4 289.3 ft2 0 0 0.6 0 8 N Exterior Concrete Block-Int Insul STAIR 9 3 0 9 4 28.0 ft2 0 0 0.6 0 9 S Exterior Concrete Block-Int Insul STAIR 9 1 0 9 4 9.3 ft2 0 0 0.6 0 10 W Exterior Concrete Block-Int Insul STAIR 9 4 0 9 4 37.3 ft2 0 0 0.6 0 11 N Exterior Concrete Block-Int InsBWRTS LOFT 9 25 0 9 4 233.3 ft2 0 0 0.6 0 12 E Exterior Concrete Block-Int InsBWRTS LOFT 9 21 0 9 4 196.0 ft2 0 0 0.6 0 13 W Exterior Concrete Block-Int InsBARTS LOFT 9 31 0 9 4 289.3 ft2 0 0 0.6 0 14 N Exterior Concrete Block-Int Ins6LECTRICAL 9 18 0 9 4 168.0 ft2 0 0 0.6 0 15 E Exterior Concrete Block-Int InsHLECTRICAL 9 12 0 9 4 112.0 ft2 0 0 0.6 0 16 S Exterior Concrete Block-Int Insul OFFICE 9 11 0 9 4 102.7 ft2 0 0 0.6 0 17 S Exterior Concrete Block-Int InsUPHOLSTER 9 13 0 9 4 121.3 ft2 0 0 0.6 0 18 W Exterior Concrete Block-Int InsUPHOLSTER 9 14 0 9 4 130.7 ft2 0 0 0.6 0 19 W Exterior Concrete Block-Int Insul WIC 9 6 0 9 4 56.0 ft2 0 0 0.6 0 _20 W Exterior Concrete Block-Int Insul BATH 9 9 0 9 4 84.0 ft2 0 0 0.6 0 _21 E Exterior Concrete Block-Int InSLGAME ROO 9 27 0 9 4 252.0 ft2 0 0 0.6 0 22 S Exterior Concrete Block-Int InsLGAME ROO 9 19 0 9 4 177.3 ft2 0 0 0.6 0 _23 N Exterior Concrete Block-Int Insul GARAG 9 46 0 17 4 797.3 ft2 0 0 0.6 0 _24 E Exterior Concrete Block-Int Insul GARAG 9 20 0 17 4 346.7 ft2 0 0 0.6 0 25 S Exterior Concrete Block-Int Insul GARAG 9 10 0 17 0 170.0 ft2 0 0 0.6 0 26 N Exterior Concrete Block-Int Insul GAR 9 6 0 9 4 56.0 ft2 0 0 0.6 0 27 E Exterior Concrete Block-Int Insul GAR 9 19 0 9 4 177.3 ft2 0 0 0.6 0 _28 S Exterior Concrete Block-Int Insul GAR 9 1 0 9 4 9.3 ft2 0 0 0.6 0 _29 W Exterior Concrete Block-Int Insul GAR 9 26 0 9 4 242.7 ft2 0 0 0.6 0 _30 W Exterior Frame-Wood WORK SHOP 11 42 9 4 392.0 ft2 0.23 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated WORKSHOP None .39 3 7 21 ft2 2 W Insulated STAIR None .39 2 10 6 10 19.4 ft2 3 E Insulated GARAG None .6 18 14 252 ft2 4 E Insulated GAR None .6 18 8 144 ft2 7/20/2017 4:01 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2014 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 S 2 Vinyl Low-E Double Yes 0.65 0.25 30.0 ft2 2 ft 0 in 1 ft 4 in None None 2 E 6 Vinyl Low-E Double Yes 0.65 0.25 25.0 ft2 6 ft 0 in 1 ft 4 in None None 3 S 7 Vinyl Low-E Double Yes 0.63 0.25 41.0 ft2 6 ft 0 in 1 ft 4 in None None 4 S 7 Vinyl Low-E Double Yes 0.65 0.25 50.0 ft2 6 ft 0 in 1 ft 4 in None None 5 E 15 Vinyl Low-E Double Yes 0.65 0.25 30.0 ft2 2 ft 0 in 1 ft 4 in None None 6 S 16 Vinyl Low-E Double Yes 0.65 0.25 20.0 ft2 2 ft 0 in 1 ft 4 in None None 7 S 17 Vinyl Low-E Double Yes 0.65 0.25 30.0 ft2 2 ft 0 in 1 ft 4 in None None 8 E 21 Vinyl Low-E Double Yes 0.65 0.25 15.0 ft2 2 ft 0 in 1 ft 4 in None None 9 E 21 Vinyl Low-E Double Yes 0.65 0.25 25.0 ft2 2 ft 0 in 1 ft 4 in None None 10 E 21 Vinyl Low-E Double Yes 0.65 0.3 48.0 ft2 2 ft 0 in 1 ft 4 in None None 11 S 22 Vinyl Low-E Double Yes 0.65 0.3 48.0 ft2 2 ft 0 in 1 ft 4 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000488 5966.9 327.58 616.06 .3565 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COP:1 34 kBtu/hr 1 sys#1 . 2 Electric Strip Heat None COP:1 17 kBtu/hr 2 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 16.5 47 kBtu/hr 1410 cfm 0.8 1 sys#1 2 Central Unit Split SEER: 16.529.4 kBtu/hr 882 cfm 0.8 2 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None UTILITY 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 it 7/20/2017 4:01 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 6 --- ---A FORM R405-2014 DUCTS ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 475 ft2 Attic 105 ft2 Default Leakage UTILITY (Default) (Default) 1 1 2 Attic 6 375 ft2 Attic 65 ft2 Default Leakage PARTS LO (Default) (Default) 2 2 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling [[ ]]Jan ]]Feb (( ]]Mar [ ]A r I ]]Ma X]]Jun X]Jul ri Aug Se [ ]Oct [ ]Nov Dec He [X]Jan lX]Feb [X]Mar [ ]Apr 1May4 ]Jun l ]Jul AuSep [ ]Oct [X]Nov Dec Ventin [ ]]]Jan [ ]Feb [X]Mar [X]A r ]May [ ]Jun [ ]Jul Aug Se [X]Oct [[X]Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 7/20/2017 4:01 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 6 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: TATAROWICZ ULTIMATE MAN CAVE Builder Name: Street: 6311 OLEANDER AVE. Permit Office: ST. LUCIE COUNTY City,State,Zip: FT. PIERCE , FL,2 Permit Number: Owner: TATAROWICA Jurisdiction: Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/doorjambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 7/20/2017 4:01 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. 6311 OLEANDER AVE., FT. PIERCE, FL, 2 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block-Int Insul, Exterior R=9.0 4748.70 ftz b. Frame-Wood, Exterior R=11.0 392.00 ft 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 0 d. N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types Insulation Area 2 a. Roof Deck(Unvented) R=20.0 2911.00 ft 6. Conditioned floor area(ft2) 4658 b. N/A R= ft2 7. Windows** Description Area c. N/A R= ft2 11. Ducts R ft2 a. U-Factor: Dbl, U=0.65 225.00 ft2 a. Sup:Attic, Ret:Attic,AH: UTILITY 6 475 SHGC: SHGC=0.25 b. Sup: Attic, Ret:Attic,AH: PARTS LOFT 6 375 b. U-Factor: Dbl, U=0.65 96.00 ft2 SHGC: SHGC=0.30 12.Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl, U=0.63 41.00 ft2 a.Central Unit 47.0 SEER:16.50 SHGC: SHGC=0.25 b.Central Unit 29.4 SEER:16.50 d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Strip Heat 34.0 COP:1.00 Area Weighted Average Overhang Depth: 3.282 ft. b. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average SHGC: 0.263 8. Floor Types Insulation Area 14. Hot water systems a. Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 2911.00 ft EF:0.97 b. N/A R= ft2 c. N/A R= ft2 b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building TliE ST Construction through the above energy saving features which will be installed (or exceeded) OF = ATF in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: a Address of New Home: City/FL Zip: ct coo wF.�o *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 7/20/2017 4:01 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 Project Summa Job: wrightsoft`� AH 1 � Date: Mar 16,zo�� By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM Proilect Information For: TATAROWICA ULTIMATE MANVCAVE 6311 OLEANDER AVE., FT. PIERCE,FL Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 °F Outside db 90 °F Inside db 70 °F Inside db 75 °F Design TD 28 °F Design TD 15 °F Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 23287 Btuh Structure 29124 Btuh Ducts 7161 Btuh Ducts 4930 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none Humidification 0 Btuh Blower e) 0 Btuh Piping 0 Btuh Equipment load 30448 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 32352 Btuh Method Sim lified Construction quality Average Latent Cooling Equipment Load Sizing Fireplaces 0 Structure 6088 Btuh Ducts 4127 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area(ftz 3068 3068 Equipment latent load 10215 Btuh Volume(ft3) 28839 28839 Air changes/hour 0.50 0.25 Equipment total load 42566 Btuh Equiv. AVF (cfm) 238 122 Req. total capacity at 0.70 SHR 3.9 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade Trade Model Cond CA16NA0480000A AHRI ref Coil FX4DNF061 AHRI ref 7893753 Efficiency 100 EFF Efficiency 13.5 EER, 16 SEER Heating input 8.8 kW Sensible cooling 32900 Btuh Heating output 30139 Btuh Latent cooling 14100 Btuh Temperature rise 18 °F Total cooling 47000 Btuh Actual air flow 1567 cfm Actual air flow 1567 cfm Air flow factor 0.051 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.77 Calculations approved by ACCA to meet all requirements of Manual J FILE COPY 8th Ed. wri htsoft" 2017-Jul-2015:59:18 9 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 1 XCICK ...rightsoft HVAC\TATAROWICZ ULTIMATE MAN CAVE.rup Calc=MJ8 Front Door faces: N Project Summary Job: - wrightsoft', Pr 2 Date: Mar 16,2017 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM Proiect Information For: TATAROWICA ULTIMATE MANVCAVE 6311 OLEANDER AVE., FT. PIERCE,FL Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 72 OF Design TD 28 OF Design TD 18 OF Daily range L Relative humidity 50 % Moisture difference 68 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 12964 Btuh Structure 12897 Btuh Ducts 3665 Btuh Ducts 2282 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none Humidification 0 Btuh Blower e) 0 Btuh Piping 0 Btuh Equipment load 16629 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 14420 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 9226 Btuh Ducts 2034 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area(ftz 1590 1590 Equipment latent load 11260 Btuh Volume (ft') 22306 22306 Air changes/hour 0.39 0.20 Equipment total load 25680 Btuh Equiv. AVF (cfm) 145 74 Req. total capacity at 0.70 SHR 1.7 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade Trade CARRIER AIR CONDITIONING Model Cond CA16NW0300000A AHRI ref Coil FX4DNB037L AHRI ref 7692728 Efficiency 80AFUE Efficiency 13.5 EER, 16 SEER Heating input 0 Btuh Sensible cooling 20580 Btuh Heating output 0 Btuh Latent cooling 8820 Btuh Temperature rise 0 OF Total cooling 29400 Btuh Actual air flow 980 cfm Actual air flow 980 cfm Air flow factor 0.059 cfm/Btuh Air flow factor 0.065 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.57 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsoft- 2017-Jul-2015:59:18 9 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 2 ..rightsoft HVAC\TATAROWICZ ULTIMATE MAN CAVE.rup Calc=MJ8 Front Door faces: N wrightsoft° Right-J®Worksheet Job: AHU 1 Date: Mar 16,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN., FT. PIERCE,FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@_AOL.COM 1 Room name AHU 1 TROPHY ROOM 2 Exposed wall 315.9 ft 27.0 ft 3 Room height 9.4 ft d 9.4 ft heat/cool 4 Room dimensions 12.0 x 14.0 ft 5 Room area 3068.0 ft' 168.0 ftz Ty Construction U-value Or HTM Area (ft') Load Area (ftl Load number (Btuh/ft'°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 \tTailored foam inject 0.000 ne 0.00 0.00 902 883 0 0 113 113 0 0 -D 11 DO 0.390 ne 10.92 11.31 19 19 210 218 0 0 0 0 W Tailored foam iniect 0.000 se 0.00 0.00 451 451 0 0 9 9 0 0 Tailored foam inject 0.000 sw 0.00 0.00 780 616 0 0 0 0 0 0 11 1 Dc2om 0.870 sw 24.36 43.38 45 22 1096 1952 0 0 0 0 1 Dc2om 0.870 sw 24.36 43.38 25 12 609 1085 0 0 0 0 1 Dc2omd 0.870 sw 24.36 49.39 48 15 1169 2371 0 0 0 0 4A5-2om 0.770 sw 21.58 19.31 25 25 539 483 0 0 0 0 11 DO 0.390 sw 10.92 11.31 21 21 229 238 0 0 0 0 11N0 0.350 sw 0.00 0.00 0 0 0 0 0 0 0 0 11 P O 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 Tailored foam inject 0.000 rrw 0.00 0.00 837 618 0 0 132 102 0 0 10D-m 1.390 nw 38.92 32.34 41 0 1588 1319 0 0 0 0 1 Dc2om 0.870 rrw 24.36 58.95 20 0 487 1179 0 0 0 0 1 D-c2om 0.870 rrw 24.36 58.95 30 0 731 1768 0 0 0 0 1 Dc2omd 0.870 nw 24.36 22.98 48 0 1169 1103 0 0 0 0 4A5-2om 0.770 nw 21.56 36.90 30 0 647 1107 30 0 647 1107 4A5-2om 0.770 nw 21.56 36.90 50 0 1078 1845 0 0 0 0 C 16X19-Oad 0.408 1.59 1.49 1971 1971 3125 2929 51 51 81 76 F 22A-toi 0.989 27.69 0.00 1280 110 3044 0 168 27 748 0 F 22A-tpl 0.989 27.69 0.00 41 8 233 0 0 0 0 0 6 c)AED excursion 7170 395 Envelope loss/gain 15955 24766 1475 1578 12 a) Infiltration 7333 2008 627 172 b) Room ventilation 0 0 0 0 13 1ntemal gains: Occupants @ 230 5 1150 0 0 Appliances/other 1200 0 Subtotal(lines 6 to 13) 1 23287 29124 2102 1749 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 23287 29124 2102 1749 15 DuctIoads 31% 17% 7161 4930 31% 17% 646 296 Total room load 30448 34054 2748 2045 Air required(cfm) 1567 1567 141 94 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft' 2017-Jul-20 15:59 age 1 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 1 ...rightsoft HVACITATAROWICZ ULTIMATE MAN CAVE.rup Calc=MJ8 Front Door faces: N wrightsoft, R1 h 1®Worksheet Job: Date: Mar 16,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax:772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name REF. LOUNGE WORK SHOP 2 Exposed wall 20.0 ft 54.9 ft 3 Room height 9.4 ft heat/cool 9.4 ft heat/cool 4 Room dimensions 1.0 x 330.0 ft 1.0 x 671.0 ft 5 Room area 330.0 ft' 671.0 ft2 Ty Construction U-value Or HTM Area (ft') Load Area (ft) Load number (Btuh/ft'°F) (Btuh/ftl) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat cool 6 %t_DTailored foam inject 0.000 ne 0.00 0.00 188 188 0 0 0 0 0 0 11 DO 0.390 ne 10.92 11.31 0 0 0 0 0 0 0 0 W Tailored foam iniect 0.000 se 0.00 0.00 0 0 0 0 9 9 0 0 Tailored foam inject 0.000 sw 0.00 0.00 0 0 0 0 216 170 0 0 11 1 Dc2om 0.870 sw 24.36 43.38 0 0 0 0 0 0 0 0 1 Dc2om 0.870 sw 24.36 43.38 0 0 0 0 0 0 0 0 1Dc2omd 0.870 sw 24.36 49.39 0 0 0 0 0 0 0 0 4A5.2om 0.770 sw 21.56 19.31 0 0 0 0 25 25 539 483 11 DO 0,390 sw 10.92 11.31 0 0 0 0 21 21 229 238 11 N0 0,350 sw 0.00 0.00 0 0 0 0 0 0 0 0 11 PO 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 Tailored foam inject 0.000 nw 0.00 0.00 0 0 0 0 291 201 0 0 10D-m 1.390 rtw 38.92 32.34 0 0 0 0 41 0 1588 1319 1 Dc2om 0.870 rrw 24.36 58.95 0 0 0 0 0 0 0 0 1 Dc2om 0.870 nw 24.36 58.95 0 0 0 0 0 0 0 0 1 Dc2omd 0.870 nw 24.36 22.98 0 0 0 0 0 0 0 0 4A5-2om 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 4A5-2om 0.770 nw 21.56 36.90 0 0 0 0 50 0 1078 1845 c 16X19-Oad 0.408 1.59 1.49 0 0 0 0 128 128 203 190 F 22A-tpl 0.989 27.69 0.00 330 20 554 0 671 55 1521 0 F 22A-tpl 0.989 - 27.69 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 0 1681 Envelope loss/gain 554 0 5158 5755 12 a) Infiltration 464 127 1276 349 b) Room ventilation 0 0 01 0 13 1ntemal gains: Occupants @ 230 4 920 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1018 1047 6434 6105 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1018 1047 6434 6105 15 Duct loads 31% 17% 313 177 31% 17% 1979 1033 Total room load 1331 1224 1 8413 7138 Air required(cfm) 68 56 433 328 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. AC A wrightsoft` 2017-Jul-20 15: e 2 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 2 nghtsoft HVAC\TATAROWICZ ULTIMATE MAN CAVE.rup Calc=MJ8 Front Door faces: N wrightsofts Right-J®Worksheet Job. AHU 1 Date: Mar 16,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN., FT. PIERCE, FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name RESTROOM PARTS LOFT 2 Exposed wall 0 ft 77.0 ft 3 Room height 9.4 ft heat/cool 9.4 ft heat/cool 4 Room dimensions 7.0 x 5.0 ft 1.0 x 376.0 ft 5 Room area 35.0 ft2 376.0 ft2 Ty Construction U-value Or HTM Area (ftJ Load Area M Load number (Btuh/W°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cod Gross N/P/S Heat Cod Gross N/P/S Heat Cool 6 t_DTailored foam inject 0.000 ne 0.00 0.00 0 0 0 0 291 291 0 0 11 DO 0.390 ne 10.92 11.31 0 0 0 0 0 0 0 0 W Tailored foam inject 0.000 se 0.00 0.00 0 0 0 0 235 235 0 0 Tailored foam inject 0.000 sw 0.00 0.00 0 0 0 0 197 197 0 0 11 1 Dc2om 0.870 sw 24.36 43.38 0 0 0 0 0 0 0 0 1 Dc2om 0.870 sw 24.36 43.38 0 0 0 0 0 0 0 0 1 Dc2omd 0.870 sw 24.36 49.39 0 0 0 0 0 0 0 0 4A5.2om 0.770 sw 21.56 19.31 0 0 0 0 0 0 0 0 11 DO 0.390 sw 10.92 11.31 0 0 0 0 0 0 0 0 11NO 0.350 sw 0.00 0.00 0 0 0 0 0 0 0 0 11 PO 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 Tailored foam inject 0.000 nw 0.00 0.00 0 0 0 0 0 0 0 0 1OD-m 1.390 nw 38.92 32.34 0 0 0 0 0 0 0 0 1 Dc2om 0.870 nw 24.36 58.95 0 0 0 0 0 0 0 0 1 Dc2om 0.870 nw 24.36 58.95 0 0 0 0 0 0 0 0 1 Dc2omd 0.870 nw 24.36 22.98 0 0 0 0 0 0 0 0 4A5.2om 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 4A5-2om 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 C 16X19-0ad 0.408 - 1.59 1.49 0 0 0 0 376 376 596 559 F 22A-tol 0.989 27.69 0.00 35 0 0 0 0 0 0 0 F 22A-tpl 0.989 - 27.69 0.00 0 0 0 0 41 8 233 0 6 c)AED excursion 0 0 Envelope loss/gain 0 0 829 558 12 a) Infiltration 0 0 1787 489 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 0 230 2615 1048 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 230 2515 1048 15 Duct loads 31% 17% 0 39 31% 17% 804 177 Total room load 0 269 ]::�� 1225 Air required(cfm) 0 12 56 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft" 2017-Jul-2015:59:18 11- Right-Sufte®Universal 2017 17.0.14 RSU08101 Page 3 ...rightsoft HVAC%TATAROWICZ ULTIMATE MAN CAVE.rup Calc=MJ8 Front Door faces: N - wrightsoft@ Right-J®Worksheet Job: AHU 1 Date: Mar 16,2017 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE,FL 34946 Phone: 772-466-6799 Fax:772-466-6796 Email:OUICKCALCS@AOL.COM 1 Room name STAIR ELECTRICAL PARTS 2 Exposed wall 8.0 ft 30.0 ft 3 Room height 9.4 ft heat/cool 9.4 ft heat/cool 4 Room dimensions 4.0 x 19.0 ft 12.0 x 18.0 ft 5 Room area 76.0 ftz 216.0 ftz Ty Construction U-value Or HTM Area (ft� Load Area (W) Load number (Btuhlft?°F) (Btuhlft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cod Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Tailored foam inject 0.0 ne 0.00 0.00 38 18 0 0 0 0 0 0 `D 00 11 DO 0.390 ne 10.92 11.31 19 19 210 218 0 0 0 0 W Tailored foam inject 0.000 se 0.00 0.00 28 28 0 0 169 169 0 0 Tailored foam inject 0.000 sw 0.00 0.00 0 0 0 0 113 83 0 0 11 1 Dc2om 0.870 sw 24.36 43.38 0 0 0 0 30 15 731 1301 1 Dc2om 0.870 sw 24.36 43.38 0 0 0 0 0 0 0 0 1 Dc2omd 0.870 sw 24.36 49.39 0 0 0 0 0 0 0 0 4A5-2om 0.770 sw 21.56 19.31 0 0 0 0 0 0 0 0 11 DO 0.390 sw 10,92 11.31 0 0 0 0 0 0 0 0 11NO 0.350 sw 0.00 0.00 0 0 0 0 0 0 0 0 11 P O 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 Tailored foam inject 0.000 rrw 0.00 0.00 9 9 0 0 0 0 0 0 10D-m 1.390 nw 38.92 32.34 0 0 0 0 0 0 0 0 1 Dc2om 0.870 rrw 24.36 58.95 0 0 0 0 0 0 0 0 1 Dc2om 0.870 rrw 24.36 58.95 0 0 0 0 0 0 0 0 1 Dc2omd 0.870 nw 24.36 22.98 0 0 0 0 0 0 0 0 4A5-2om 0.770 rrw 21.56 36.90 0 0 0 0 0 0 0 0 4A5-2om 0.770 rrw 21.56 36.90 0 0 0 0 0 0 0 0 C 16X19-0ad 0.408 - 1.59 1.49 4 4 6 6 216 216 342 321 F 22A-tol 0.989 27.69 0.00 76 8 222 0 0 0 0 0 F 22A-tpl 0.989 - 27.69 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 0 851 Envelope loss/gain 438 224 1073 2473 12 a) Infiltration 186 51 696 191 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 624 275 1769 2664 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 624 275 1769 2664 15 Duct loads 31% 17% 192 46 31% 17% 544 451 Total room load 816 321 2314 3115 Air required(cfm) 42 15 119 143 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft` 2017-Jul-20 15:59 age 4 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 4 ...rightsoft HVAC\TATAROWICZ ULTIMATE MAN CAVE.rup Calc=MJ8 Front Door faces: N wrightsoft` Right-J®Worksheet Job: AHU 1 Date: Mar 16,2017 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE,FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS@_4OL.COM 1 Room name OFFICE UPHOLSTERY 2 Exposed wall 11.0 ft 27.0 ft 3 Room height 9.4 ft heat cool 9.4 ft heat/cool 4 Room dimensions 11.0 x 11.0 ft 1.0 x 206.0 ft 5 Room area 121.0 ft2 206.0 ft' Ty Construction U-value Or HTM Area (ft2) Load Area (ftJ Load number (Btuh/W'F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cod Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V►J Tailored foam inject 0.000 ne 0.00 0.00 0 0 0 0 132 132 0 0 �p 11 DO 0.390 ne 10.92 11.31 0 0 0 0 0 0 0 0 W Tailored foam inject 0.000 se 0.00 0.00 0 0 0 0 0 0 0 0 Tailored foam inject 0.000 sw 0.00 0.00 0 0 0 0 0 0 0 0 11 1 Dc2om 0.870 sw 24.36 43.38 0 0 0 0 0 0 0 0 1 Dc2om 0.870 sw 24.36 43.38 0 0 0 0 0 0 0 0 1 Dc2omd 0.870 sw 24.36 49.39 0 0 0 0 0 0 0 0 4A5-2om 0.770 sw 21.56 19.31 0 0 0 0 0 0 0 0 11 DO 0.390 sw 10.92 11.31 0 0 0 0 0 0 0 0 11N0 0.350 sw 0.00 0.00 0 0 0 0 0 0 0 0 11 P O 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 Tailored foam inject 0.000 nw 0.00 0.00 103 83 0 0 122 92 0 0 10D-m 1.390 nw 38.92 32.34 0 0 0 0 0 0 0 0 1 Dc2om 0.870 nw 24.36 58.95 20 0 487 1179 0 0 0 0 1 Dc2om 0.870 nw 24.36 58.95 0 0 0 0 30 0 731 1768 1 Dc2omd 0.870 nw 24.36 22.98 0 0 0 0 0 0 0 0 4A5-2om 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 4A5-2om 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 C 16X19-0ad 0.408 - 1.59 1.49 121 121 192 180 206 206 327 306 F 22A-tol 0.989 - 27.69 0.00 0 0 0 0 0 0 0 0 F 22A-tpl 0.989 - 27.69 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 499 748 Envelope loss/gain 679 1858 1057 2823 12 a) Infiltration 255 70 627 172 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 934 1928 1684 2994 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 934 1928 1684 2994 15 Ductloads 31% 17% 287 326 31% 17% 518 507 Total room load 1222 2254 1 1 2202 3501 Air required(cfm) 63 104 113 161 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .4-6- _Pk wrightsoft- 2017-Jul-2015:59:18 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 5 ...rightsoft HVAC\TATAROWICZ ULTIMATE MAN CAVE.rup Calc=MJ8 Front Door faces: N wrightsoft• Right-J®Worksheet Job: AHU 1 Date: Mar 16,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax:772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name WIC BATH 2 Exposed wall 6.0 ft 9.0 ft 3 Room height 9.4 ft heat/cool 9.4 ft heat/cool 4 Room dimensions 6.0 x 6.0 ft 1.0 x 98.0 ft 5 Room area 36.0 ft' 98.0 ft2 Ty Construction U-value Or HTM Area (ft') Load Area (ft� Load number (BtuWW°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cod Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W✓ Tailored foam inject 0.000 ne 0.00 0,00 56 56 0 0 85 85 0 0 �D 11 DO 0.390 ne 10.92 11.31 0 0 0 0 0 0 0 0 W Tailored foam inject 0.000 se 0.00 0.00 0 0 0 0 0 0 0 0 Tailored foam inject 0.000 sw 0.00 0.00 0 0 0 0 0 0 0 0 11 1 Dc2om 0.870 sw 24.36 43.38 0 0 0 0 0 0 0 0 1 Dc2om 0.870 sw 24.36 43.38 0 0 0 0 0 0 0 0 1 D-c2omd 0.870 sw 24.36 49.39 0 0 0 0 0 0 0 0 4A5-2om 0.770 sw 21.56 19.31 0 0 0 0 0 0 0 0 11 DO 0.390 sw 10.92 11.31 0 0 0 0 0 0 0 0 11N0 0.350 sw 0.00 0.00 0 0 0 0 0 0 0 0 11 P O 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 Tailored foam inject 0.000 nw 0.00 0.00 0 0 0 0 0 0 0 0 10D-m 1.390 nw 38.92 32.34 0 0 0 0 0 0 0 0 1Dc2om 0.870 nw 24.36 58.95 0 0 0 0 0 0 0 0 1 Dc2om 0.870 nw 24.36 58.95 0 0 0 0 0 0 0 0 1 Dc2omd 0.870 rra 24.36 22.98 0 0 0 0 0 0 0 0 4A5-2om 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 4A5-2om 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 C 16X19-Oad 0.408 1.59 1.49 36 36 57 53 98 98 155 146 F 22A-tol 0.989 27.69 0.00 0 0 0 0 0 0 0 0 F 22A-tpl 0.989 27.69 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 0 0 Envelope loss/gain 57 53 155 146 12 a) Infiltration 139 38 209 57 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 196 92 364 203 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 196 92 364 203 15 Duct loads 31% 17% 60 16 31% 17% 112 34 Total room load 257 107 476 237 Air required(cfm) 13 5 25 11 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .9C A �- wrightsoft' 2017-Jul-20 15:59:18 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 6 ..rightsoft HVAC\TATAROWICZ ULTIMATE MAN CAVE.rup Calc=MJ8 Front Door faces: N wrightscift} R1 ht1®Worksheet Job: AM Date: Mar 16,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN., FT. PIERCE, FL 34946 Phone:772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name UTILITY BATH 2 2 Exposed wall O ft O ft 3 Room height 9.4 ft heat/cod 9.4 ft heat/cool 4 Room dimensions 1.0 x 62.0 ft 8.0 x 10.0 ft 5 Room area 62,0 ftz 80.0 ftz Ty Construction U-value Or HTM Area (ft2) Load Area (ftz Load number (BtuhJW°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cod Gross N/P/S Heat Cod Gross N/P/S Heat Cod 6 Tailored foam inject 0.000 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 DO 0.390 ne 10.92 11.31 0 0 0 0 0 0 0 0 W Tailored foam inject 0.000 se 0.00 0.00 0 0 0 0 0 0 0 0 Tailored foam inject 0.000 sw 0.00 0.00 0 0 0 0 0 0 0 0 11 G 1Dc2om 0.870 sw 24.36 43.38 0 0 0 0 0 0 0 0 1 D-c2om 0.870 sw 24.36 43.38 0 0 0 0 0 0 0 0 1Dc2omd 0.870 sw 24.36 49.39 0 0 0 0 0 0 0 0 4A5-2om 0.770 sw 21.56 19.31 0 0 0 0 0 0 0 0 11 DO 0.390 sw 10.92 11.31 0 0 0 0 0 0 0 0 11N0 0.350 sw 0.00 0.00 0 0 0 0 0 0 0 0 11P0 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 Tailored foam inject 0.000 nw 0.00 0.00 0 0 0 0 0 0 0 0 10D-m 1.390 nw 38.92 32.34 0 0 0 0 0 0 0 0 1 D-c2om 0.870 nw 24.36 58.95 0 0 0 0 0 0 0 0 1 D-c2om 0.870 rrw 24.36 58.95 0 0 0 0 0 0 0 0 1 D-c2omd 0.870 nw 24.36 22.98 0 0 0 0 0 0 0 0 4A5-2om 0.770 rrw 21.56 36.90 0 0 0 0 0 0 0 0 4A5-2om 0.770 rrw 21.56 36.90 0 0 0 0 0 0 0 0 C 16X19-Oad 0.408 - 1.59 1.49 62 62 98 92 80 80 127 119 F 22A-tpl 0.989 27.69 0.00 0 0 0 0 0 0 0 0 F 22A-tpl 0.989 27.69 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 0 0 Envelope loss/gain 98 92 127 119 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 98 92 127 119 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 98 92 127 119 15 Duct loads 31% 17% 30 16 31% 17% 39 20 Total room load 129 108 166 139 Air required(cfm) 7 51 i 9 6 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �A _rk wrightsoftm 2017-Jul-20 15:59:18 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 7 ...rightsoft HVAC\TATAROWICZ ULTIMATE MAN CAVE.rup Calc=MJ8 Front Door faces: N wrightsok Right-J® Worksheet Job: AHU 1 Date: Mar 16,2017 By: QUICK CALCS, INC. 317 ST. LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name HALL GAME ROOM 2 Exposed wall 0 ft 46.0 ft 3 Room height 9.4 ft heat/cool 9.4 ft heat/cool 4 Room dimensions 1.0 x 95.0 ft 1.0 x 498.0 ft 5 Room area 95.0 ft' 498.0 ft2 Ty Construction U-value Or HTM Area (ft� Load Area (ft) Load number (13tuh/ft2-'F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Tailored foam inject 0.000 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 DO 0.390 ne 10.92 11.31 0 0 0 0 0 0 0 0 W Tailored foam inject 0.000 se 0.00 0.00 0 0 0 0 0 0 0 0 Tailored foam inject 0.000 sw 0.00 0.00 0 0 0 0 254 166 0 0 11 1 D-c2om 0.870 sw 24.36 43.38 0 0 0 0 15 7 365 651 1 D-c2om 0.870 sw 24.36 43.38 0 0 0 0 25 12 609 1085 1 Dc2omd 0.870 sw 24.36 49.39 0 0 0 0 48 15 1169 2371 4A5-2om 0.770 sw 21.56 19.31 0 0 0 0 0 0 0 0 11 DO 0.390 sw 10.92 11.31 0 0 0 0 0 0 0 0 11N0 0.350 sw 0.00 0.00 0 0 0 0 0 0 0 0 11 P O 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 Tailored foam inject 0.000 rna 0.00 0.00 0 0 0 0 179 131 0 0 10D-m 1.390 rrw 38.92 32.34 0 0 0 0 0 0 0 0 1 D-c2om 0.870 nw 24.36 58.95 0 0 0 0 0 0 0 0 1 D-c2om 0.870 nw 24.36 58.95 0 0 0 0 0 0 0 0 1 Dc2omd 0.870 nw 24.36 22.98 0 0 0 0 48 0 1169 1103 4A5-2om 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 4A5-2om 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 C 16X19-Oad 0.408 1.59 1.49 95 95 151 141 498 498 790 740 F 22A-tol 0.989 27.69 0.00 0 0 0 0 0 0 0 0 F 22A-tpl 0.989 27.69 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion p 2997 Envelope loss/gain 151 141 4103 8947 12 a) Infiltration 0 0 1067 292 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 1200 Subtotal(lines 6 to 13) 151 141 5170 10439 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 151 141 5170 10439 15 Duct loads 31% 17% 46 24 31% 17% 1590 1767 Total room load 197 165 6760 12206 Air required(cfm) 10 8 1 1 348 562 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft` 2017-Jul-20 15:59 8 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 8 ...rightsoft HVAC\TATAROWICZ ULTIMATE MAN CAVE.rup Calc=MJ8 Front Door faces: N - wrightsoftm Vht-M) U Worksheet Job: Date: Mar 16,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name AHU 2 GARAGE 2 Exposed wall 128.0 ft 76.0 ft 3 Room height 14.0 ft d 17.4 ft heat/cool 4 Room dimensions 20.0 x 46.0 ft 5 Room area 1590.0 ft' 920.0 ft2 Ty Construction U-value Or HTM Area (W) Load Area (ft� Load number (Btuh/ft'°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat cool Gross N/P/S Heat Cod Gross N/P/S Heat Cool Tailored foam inject 0.000 ne 0.00 0.00 244 244 0 0 0 0 0 0 6 %t-D 11 DO 0.390 ne 0.00 0.00 0 0 0 0 0 0 0 0 W Tailored foam iniect 0.000 se 0.00 0.00 857 857 0 0 800 800 0 0 Tailored foam inject 0.000 sw 0.00 0.00 527 131 0 0 348 96 0 0 11 1 D-c2om 0.870 sw 0.00 0.00 0 0 0 0 0 0 0 0 1 D-c2om 0.870 sw 0.00 0.00 0 0 0 0 0 0 0 0 1 Dc2omd 0.870 sw 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om 0.770 sw 0.00 0.00 0 0 0 0 0 0 0 0 11 DO 0.390 sw 0.00 0.00 0 0 0 0 0 0 0 0 11 NO 0.350 sw 9.80 11.20 144 144 1411 1613 0 0 0 0 11P0 0.290 sw 8.12 9.28 252 252 2046 2339 252 252 2046 2339 Tailored foam inject 0.000 nw, 0.00 0.00 183 183 0 0 174 174 0 0 10D-m 1.390 rmv 0.00 0.00 0 0 0 0 0 0 0 0 1 D-c2om 0.870 nw 0.00 0.00 0 0 0 0 0 0 0 0 1 D-c2om 0.870 nw, 0.00 0.00 0 0 0 0 0 0 0 0 1 Dc2omd 0.870 rrw 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om 0.770 nw 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2om 0.770 nw 0.00 0.00 0 0 0 0 0 0 0 0 C 16X19-0ad 0.408 - 1.59 1.66 940 940 1490 1557 920 920 1459 1523 F 22A-td 0.989 27.69 0.00 1590 128 3545 0 920 76 2105 0 F 22A-tpl 0.989 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 0 0 Envelope loss/gain 8492 5508 5610 3862 12 a) Infiltration 4471 1469 3264 1073 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 4 920 4 920 Appliances/other 5000 3000 Subtotal(lines 6 to 13) 12964 12897 8874 8855 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 12964 12897 8874 8855 15 Duct loads 28% 18% 3665 2282 28% 18% 2509 1567 Total room load 16629 15179 11383 10421 Air required(cfm) 980 980 671 673 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 'Fk wrightsoft- 2017-Jul-2015:59:18 Right-Suite®Universal 2017 17.0.14 RSU08101 page 9 '��p` ...rightsoft HVAC\TATAROWICZ ULTIMATE MAN CAVE.rup Calc=MJ8 Front Door faces: N wrightsoft' Vht-J@ Worksheet Job: U 2 Date: Mar 16,2017 By: QUICK CALCS, INC. 317 ST.LUCIE LN., FT. PIERCE,FL 34946 Phone: 772-466-6799 Fax:772-466-6796 Email: QUICKCALCS@,AOL.COM 1 Room name GARAGE. 2 Exposed wall 52.0 ft 3 Room height 9.4 ft heat/cool 4 Room dimensions 1.0 x 670.0 ft 5 Room area 670.0 ft2 Ty Construction U-value Or HTM Area (ft1) Load Area Load number (Btuh/ft2°F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 \ _D Tailored foam inject 0.000 ne 0.00 0.00 244 244 0 0 11 DO 0.390 ne 0.00 0.00 0 0 0 0 W Tailored foam iniect 0.000 se 0.00 0.00 56 56 0 0 Tailored foam inject 0.000 sw 0.00 0.00 179 35 0 0 11 G 1Dc2om 0.870 sw 0.00 0.00 0 0 0 0 1 Dc2om 0.870 sw 0.00 0.00 0 0 0 0 1 Dc2omd 0.870 sw 0.00 0.00 0 0 0 0 4A5-2om 0.770 sw 0.00 0.00 0 0 0 0 11 DO 0.390 sw 0.00 0.00 0 0 0 0 11N0 0.350 sw 9.80 11.20 144 144 1411 1613 11 P O 0.290 sw 8.12 9.28 0 0 0 0 Tailored foam inject 0.000 nw 0.00 0.00 9 9 0 0 10D-m 1.390 n v 0.00 0.00 0 0 0 0 1 Dc2om 0.870 nw 0.00 0.00 0 0 0 0 1 Dc2om 0.870 nw 0.00 0.00 0 0 0 0 1 Dc2omd 0.870 nw 0.00 0.00 0 0 0 0 4A5-2om 0.770 nw 0.00 0.00 0 0 0 0 4A5-2om 0.770 nw 0.00 0.00 0 0 0 0 C 16X19-0ad 0.408 1.59 1.66 20 20 32 33 F 22A-tol 0.989 27.69 0.00 670 52 1440 0 F 22A-tpl 0.989 0.00 0.00 0 0 0 0 6 c)AED excursion 0 Envelope loss/gain 2883 1646 12 a) Infiltration 1207 396 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 2000 Subtotal(lines 6 to 13) 4090 4042 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 4090 4042 15 Duct Ioeds 28% 18% 1156 715 Total room load 5246 4758 Air required(cfm) 309 307 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .4C�A � wrightsoft` 2017-Jul-20 15:59:18 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 10 ..rightsoft HVAC\TATAROWICZ ULTIMATE MAN CAVE.rup Calc=MJ8 Front Door faces: N Duct System Summary Job: - wrightsoft° Date: Mar 16,2017 AHU 1 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email QUICKCALCS@AOLCOM Project Information For: TATAROWICA ULTIMATE MANVCAVE 6311 OLEANDER AVE., FT. PIERCE,FL Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/ return available pressure 0.250/ 0.250 in H2O 0.250/ 0.250 in H2O Lowest friction rate 0.173 in/100ft 0.173 in/100ft Actual air flow 1567 cfm 1567 cfm Total effective length (TEL) 288 ft SupplyDetail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (Cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk BATH h 476 25 11 0.378 4.0 Ox 0 VIFx 17.2 115.0 st4 BATH 2 h 166 9 6 0.377 4.0 Ox 0 VIFx 17.7 115.0 st4 ELECTRICAL PARTS c 3115 119 143 0.335 7.0 Ox0 VIFx 34.3 115.0 st5 GAME ROOM c 3052 87 140 0.360 6.0 Ox0 VIFx 24.0 115.0 st5 GAME ROOM-A c 3052 87 140 0.365 6.0 Ox0 VIFx 22.0 115.0 st5 GAME ROOM-B C 3052 87 140 0.350 6.0 Ox0 VIFx 27.7 115.0 st5 GAME ROOM-C c 3052 87 140 0.356 6.0 Ox0 VIFx 25.3 115.0 st5 HALL h 165 10 8 0 0 Ox0 VIFx 0 0 OFFICE c 2254 63 104 0.350 7.0 Ox 0 VIFx 27.8 115.0 st5 PARTS LOFT h 1710 88 28 0.425 7.0 Ox 0 VIFx 22.7 95.0 PARTS LOFT-A h 1710 88 28 0.487 7.0 Ox0 VIFx 7.6 95.0 REF.LOUNGE h 1331 68 56 0.313 7.0 Ox0 VIFx 25.0 135.0 st6 RESTROOM c 269 0 12 0 0 OXO VIFx 0 0 STAIR h 321 42 15 0 0 Ox 0 VIFx 0 0 TROPHY ROOM h 2748 141 94 0.261 7.0 Ox 0 VIFx 36.2 155.0 st6 UPHOLSTERY c 3501 113 161 0.363 7.0 Ox 0 VIFx 22.6 115.0 st4 UTILITY h 129 7 5 0.500 4.0 Ox 0 VIFx 5.0 95.0 WIC h 257 13 5 0.378 4.0 Ox 0 VIFx 17.2 115.0 st4 WORKSHOP h 2804 144 109 0.197 7.0 Ox 0 VIFx 39.0 215.0 st7 WORK SHOP-A h 2804 144 109 0.173 7.0 Ox 0 VIFx 53.2 235.0 st7 WORK SHOP-B h 2804 144 109 0.215 7.0 Ox0 VIFx 38.0 195.0 st7 Wrl htsoft 2017-Jul-2015:59:20 „� 9 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 1 ACCA ...rightsoft HVAC\TATAROWICZ ULTIMATE MAN CAVE.rup Calc=MJ8 Front Door faces: N SupplyDetail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st3 Peak AVF 643 479 0.173 818 12.0 0 x 0 VinlFlx st6 Peak AVF 643 479 0.173 818 12.0 0 x 0 VinlFlx st3 st7 Peak AVF 433 328 0.173 656 11.0 0 x 0 VinlFlx st6 st4 Peak AVF 160 183 0.363 686 7.0 0 x 0 VinlFlx st5 Peak AVF 530 809 0.335 877 13.0 0 x 0 VinlFlx TableReturn Branch Detail Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening (in) Matl Trunk rb3 Ox0 1567 1567 0 0 0 0 Ox 0 VIFx 2017-Jul-20 15:59:20 wrightSoft`• Right-Suite®Universal 2017 17.0.14 RSU08101 Page 2 ACCK ...rightsoft HVAC\TATAROWICZ ULTIMATE MAN CAVE.rup Calc=MJ8 Front Door faces: N Duct System Summary Job: wrightsoft' y Date: Mar 16,2017 AHU 2 By: QUICK CALCS, INC. 317 ST. LUCIE LN FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email QUICKCALCS@AOL.COM -Project Information For: TATAROWICA ULTIMATE MANVCAVE 6311 OLEANDERAVE., FT. PIERCE,FL Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/ return available pressure 0.250/ 0.250 in H2O 0.250/ 0.250 in H2O Lowest friction rate 0.208 in/100ft 0.208 in/100ft Actual air flow 980 cfm 980 cfm Total effective length (TEL) 240 ft Supply Branch DetailTable Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FIR (in) (in) Matl Ln (ft) Ln (ft) Trunk GARAGE-A c 3474 224 224 0.208 7.0 Ox0 VIFx 35.4 205.0 st2 GARAGE-B c 3474 224 224 0.236 8.0 Ox0 VIFx 27.2 185.0 st2 GARAGE-C c 3474 224 224 0.247 8.0 Ox 0 VIFx 37.2 165.0 st2 GARAGE. h 5246 309 307 0.212 9.0 Ox0 VIFx 31.0 205.0 st2 SupplyTrunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st2 Peak AVF 980 980 0.208 1248 12.0 0 x 0 VinlFlx TableReturn Branch Detail Grille Htg CIg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening (in) Matl Trunk rb4 Ox 0 980 980 0 0 0 0 Ox 0 VIFx wri htsoft' 2017-Jul-2015:59i20 g Right-Suite®Universal 2017 17.0.14 RSU08101 Page 3 CCK ..rightsoft HVAC\TATAROWICZ ULTIMATE MAN CAVE.rup Calc=MJ8 Front Door faces: N