HomeMy WebLinkAboutProduct approvals, underlayments i I
.BCIS Home { Log.I6 User Registration Hot Topics ! Submit Surcharge ', Stats&Facts ( Publications j FBC Staff ,BCIS Site Map,r Links i, Search j
=10 ida
,
i Product Approval
dl ,�� r
USER:-Public User
Product Approval M-g>.Product or Application 9—rch'>Anrilicat inn I i >Application Detail
ill I k
J N d FL# FL16048-R3
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived �-
Product Manufacturer TRI-BUILT Roofing Products
Address/Phone/Email 9050 Louisiana Street
Merrillville,IN 46410
(201)842-2449
david.ruiz@tribuiitmaterialsgroup.com
Authorized-Signature David Ruiz
d.avid.ruiz@tribuilt,m6,tEirialsgroup.com
Technical Representative David Ruiz
Address/Phone/Email 250 Route 17 North
East Rutherford,N]07073
(201)842-2449
david.ruiz@bibuiltmaterialsgroup.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
D Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality-Assurance Contract Expiration Date 10/16/2017
Validated By John W.Knezevich,PE
�E Validation Checklist-Hardcopy Received
Certificate of Independence FL16048 R3 COI 2015 01 COI Nieminen odf
i
Referenced Standard and Year(of Standard) Standard .Year
ASTM D1970 2009
ASTM G155 2005
FRSA/TRI April 2012(04-12) 2012
TAS 103 1995
Equivalence of Product Standard_s
Certified By
Sections from the Code
i
i
i
I
n
I I
Product Approval Method Method i Option D
Date Submitted 10/08/2015
Date Validated 10/19/2015
Date.Pending FBC Approval 10/21/2015
Date Approved 12/15/2015
Date Revised 10106/2016
Summary of Products
FL# Model,Number or Name Description
16048.1 TRI-BUILT Roof Underlayments Self.-adhering,modified bitumen roof underlayments
Limits of Use Installation_Instructions
Approved for use in HVHZ:-No FL16048 R3 I1 2015 10 FINAL ER TRI-
.Approved for use outside HVHZ:Yes BUILT UNDERLAYMENTS FL16048-R3.odf
impact Resistant-N/A Verified By:Robert Nieminen P&59166
Design Pressure..+N/A/-45 Created by Independent Third Party:Yes
Other:1.)The design pressure.noted herein pertains to use Evaluation Reports
of foam-on tile systems overtop the self-adhering Fl l F�0 33 "e 2015 10 FINAL ER TRI-
underlayment for one particular application'.See ER Section BUILT UNDERLAYMENTS FL16048-R3 odf
5.6 for details.2.)Refer to ER Section 5 for other Limits of Created by Independent Third Party:Yes
Use,
Back Next
i
contact Us.:2601 sialr 5tone Road,Tallahassee FL 32399 Phone:850-487-1824
I
The State of norida is an AA/EEo employee Comwaht 2007-2013 State o/.Flo da Privacv5tatement:c Accessibility StatemenK :Rrifund Statement
.Under Florlda law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic
mail.to this entity.instead,contact the office by phone or by traditional mall.If you have any.4uestions,please contact 850.487.1395.-Pursuant to section-455.275
(1),Florida statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide_the Department with an emailaddress if they:have one.The
emails provided may be used for official communication with the Ikensee.However email addresses are public record.If you do not wish to supply a personal address,
please provide the Department with an email address whkh.can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please
dick here.
Product Approval Accepts:
E— Fag—gg
Credit Card'.
Safe._
I
�I
I I
I
' I
EXTERIOR RESEARCH-&DESIGN,LLCI;.
Certificate of Authorization#9503
\Y TR1N1 1 353 CHRISTIAN STREET;UNIT,#23
ERD OXFORD,CT 06478
PHONE (203)262-9245
FAX:_(203)262-9243
EVALUATION REPORT
Allied Building Products Corp; Evaluation ReportA41960.10127113.
dba TRI-BUILT Roofing Products FL16048-113
9050 Louisiana Street Date of Issuance:10/25/2022
Merrillville,IN 46410 Revision3c 10/08/201S
i
SCOPE:
This Evaluation Report is issued under Rule61G20-3.and.the applicable rules and regulations governing the use of
construction.materials in:the State of Florida:The documentation submitted has been reviewed by Robert.Nieminen,
P.E. for use of the product.under'the Florida Building Code and Florida Building Code, Residential Volume.. The
products :described herein,have been evaluated for compliance with the 5th Edition(2014) Florida Building Code:
sections.noted herein.
DESCRIPTION TRI-BUILT Roof Underlayments
LABELING: .Labeling shall be in accordance with the requirements the.Accredited Quality Assurance Agency noted
herein:
CONTINUED COMPLIANCE:This Evaluation Report is valid until such time as.the named products)changes,the referenced
Quality Assurance documentation,changes;or provisions of the Code that relate,to the productchange. Acceptance of
this Evaluation Report•by:the named.client constitutes agreement to. notify Robert Nieminen, P:E. if the;product
changes or the referenced Quality Assurance documentation changes.. Trinity)ERD requires a complete review.cl this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT:The Evaluation Report number preceded by the words'''TrinityIERD Evaluated" may be displayed 'In
advertising,literature. If portion of the Evaluation Re ort`is dis la edi then it shall be done in its
p P y entirety. �
INSPECTICIN:,UpOn request,a copy of this entire`Evaluation Report shall be provided to the,user by the manufacturer'or
its distributors and shall be available for inspection at the job site at the request of the.Building Official.
This Evaluation Report consists,of pages 1 through 5.
Prepared by: yU��trtlrn,,,t�
Robert J.M.Nieminen;P.E., r+FS •• 4 v ThefacsimneseatappearingvrasauthoiizedbyRober[Niendnen,
P.E.on10j081201$.This doesnotsemeasanelectronicanysigned
Florida Registration No.59166,;Florida DGA ANE1983 dacumeiiL signed,waled hardcoples have beebtrad mined to the
Product Approval Administrator and to the named cuerd
CERTIFICATIONV.INDEPENDENCE:
1. TrinitylERD does.not have, nor-does it intend to':-acquire or will it acquire,a financial interest in any company manufacturing or
distributing products it evaluates:
2. Trin'ttyIERD is not:owned;operated or controlled`by any companymanufacturing.or distributing products it evaluates
3. Robert.Nieminen,-P.E.does not have nor w fl'acquire,a financial interest in any,company manufacturing or distributing products,for
which the evaluation reports are.being issued. ,
4. Robert Nieminen,•P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation_ Neither' ERD nor Robert Nieminen,;P.E: are,in anyway,the Designer of Record for any
p p /. permitting g g . ed
roject on which this Evaluation Report,or previous versions thereof is was.tued for 'ermtttin or design uidance'unless retain
specificallyfo rthatpurpose.
i
t ,
i f
'\JTI-IN! {ERO
ROOFING COMPONENT EVA umiom
1. SCOPE:
Product,Category: Roofing
Sub-Category: Underlayment
Compliance Statement: TRhBUILT Roof Underlayrnents,.as produced by TRI-BUILT;have demonstrated;.compliance
g g g g g
with the following sections of the Florida Buildin Code through testing,in.accordance'with the fohowin ':Standards;
Compliance is subject to the Installation Requirements and.Umitations/Conditions of Use set forth herein.
2. STANOARUS:
Section Property Standard Year
1507.2.4,1507.2.8,,1507.2.9 2; Physical Properties: ASTMD1970 2009
1507.4:5.1,1507.5.3,1507.7.3
1504.E Accelerated Weathering ASTM.G155 2005
1507.3.3, Installation-Practice, FR.SA/TRI April 2012(04-12) 2012
1523.6.5.2.1 Physical Properties_ TA5103 1995
3. REFERENCES:
fnifty Eaatninatiori Reference Date
ERD(TST6049) Physical Properties S46540.02.13-1 02/19/2013
ERD(TST6049) Physical Properties S40540.11.13 11/19/2013
ERD(TST6049) Physical Properties S40540.03:14 D3/26/2014
ERD(T5T6049) Physical Properties 544870.04.14-2 04/02/2014
ERD(TST6049) Physical Properties S44870.04.14-3 04/02/2614
ERD(TST6049) Physical Properties S44870.04.144 04/10/2014
ERD(TST6049) Physical'•Properties 544870.04.14-4 04/10/2014
ERD(TST,6049) Physical Properties S43530.02.14-1-R1 05/14/2014
ERD(TST6049) Physical Pro 5 '14
perties 5 '30.05. 05/28/2024
ERD(TST6049) Physical Properties S40540:10.14 10/31/2014
ERD-(TST6049) Physical Properties. SC7645.'02:15 02/13/2015
ERD(TST6049) Accelerated Weathering SC8520:04:15 05/27/2015
UL,LLC.(QUA9625) Quality.Control Multiple-Listing R16814 D9/04/2015I
UL,LLC.(QUA9625) Quality Control Service Confirmation. Exp.10/16/2017
4. PRODuc(DESCRIPTIQN:
4.1 Self-Adhering-Underlayments:
4.1A Tri-Built.Sand-R SA Shingle Underlayment:is a self-adhering,.glass-mat- reinforced, sand-surfaced, Sgs
.modified bitumen roof underlaY ment,with a 36=inch sheet width.
4.1.2 Tri=Built S/A.,HT TU Underlayment is a self-adhering, non-woven polyester fabric surfaced;-SBS`modified
I
bitumen roof underlayment
4.1.3 Tri-Built Smooth HT S/A Underlayment is a self-adhering,glass-mat reinforced;film-surfaced,SBS modified
i
bitumen roofunderlayment.
S. WITATIQNS:
j
5.1 This is a building code evaluation. Neither Trinity]ERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for.any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting;or design guidance unless retained.specifcallyforthat purpose.
5.2 This Evaluation Report is'not for use.in the HVHZ.
5.3 Fire Classification is rit s of h s product.
is Evaluation Report; refer to current_Approved Roofing Materials
Directory for fire rating
Exterior Research and oesign,LLC. Evaluation Report A42960.10.12-R3
eertiflrame afAuthorizadanM03 FL1604843
Revision 3:10/0812015
Pege 2 4',r.
I
I � I
I
I
5.4 TRkBUILT Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents: If not listed,a:request may be made to the AHJ-for approval
based on this evaluation combined:with supporting data forthe prepared.roof covering.
5.5 Allowable roof:covers applied atop the underlayments are as.follows:
r Taai e 1 PtOOE Coven,,Tp s
Asphalt WoadShakes
Underlayment Nail-On Tile Foam-On Tile Metal Slate
Shingles &Shingles,
Tri-Built Sand-R SA Shingle Yes No No No Yes Yes
Underlaymeni
i
Tri-Built S/A HT TU Yes
Yes Yes Yes Yes Yes
Underlayment See5.5.1
Tri-Built Smooth HT S/A Yes No No Yes Yes Yes
Underlayment
5.5.1 "Foam-On Tile" is limited to;:use of the following,.Approved the adhesives unless tensile adhesion I Ion-'
term aging data-from an accredited testing.laboratory is provided.
Tri-builtS/A HT TU Underlayment with.31VITM'2-Component Roof Tile Adhesive AH-160-(FL6332)or DoW!
TileBond-Roof Tile Adhesive(FL717)
5.6 Allowable substrates are noted below:
5.6.1, Direct-Bond to Deck:
i
Tri-Built Sand-R,SA Shingle'Underlayment;Tri-Built$/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to;
Plywood, ASTM D41 primed.-plywood OSB; ASTM D41 primed OSB; ASTM D41 primed structural I
concrete,.
While not required over plywood,OSB or Southern-Yellow Pine substrates,_TRI-BUILT recommends priming
the deck if the,final roof cover is not slated•for installation within 24 hours. Note:.TRI-BUILT requires
tongue-and_groove board decking be covered'with plywood.or :OSB prior to installation of the self=
adhering Underlayment.,
5.6.2 113ond4o-Insulation:
Tri-Built S/A HT TU Underlayment applied to:
9 'Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product.Approval.. For installations.
under foam-on tile systems,insulation attachment shall he designed by a qualified design professional and
installed based on testing of the insulation/Underlayment systemrin accordance with FM 4474,Appendix.D
orTAS 114,Appendix.].
5.6.3 Bond to Mechanically Attached Base Layer:
➢ ASTM 0226„Typ.e I or 11 felt.
For.installations under mechanically.attachedprepared roof coverings, base layer.shall be attached per !
minimum.codified requirements. for installations under foam:on tile systems;base layer shall be attache iId
per minimum requirements-of FRSA/TRI April 2012(04-12).
I
I
Design, 3
Exterior Research and Desi LLG Evaluation RepotEA42960.10.12-R
Cadfbg&of Authadzation#9503 FL1604946
Revislom3:16/08/201s
Page 3 of 5
i
i
I
5.7 Exbowre',Eimitations:
5.7.1 Tri-Built Sand-R S ingle Underlayment or Tri-Built Smooth HT Underlayment shall not be left
exposed for longeln 30-day :after installation
5.7.2. Tri-Built S/A-HT TU Underlayment.shall not be left exposed for longer than 180-days after installation.
6. INSTALLATION:
6.1 TRI=BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT published installation
requirements subject to the Umitations set forth in Section 5 herein and the-specifics noted below.
6.2 Re-fasten any loose decking.panels,and check protruding nail heads: Sweep the substrate thoroughly
to reinoVe any dust and debris prior to application,and prime the substrate(ifapplicable),
6.3 Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT'SlA
UnderlayMent-
6;3.1_ Shall be,installed in compliance with the:requirements for.ASTM.D1970 underlayment in FBC Sections
1507 forthe type of prepared ropf covering to be installed.
6:3.2 Non-Tile'applications:
While priming is:optional,TRI-BUILT recommends priming;the deck if the final roof cover:is not slated for
installation;withi.n;24 hours.
Apply sheet`parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first
ft of release film.
Adherethe;exposed,part to the substrate;and unroll the remaining membrane as far as possible.
Once-the entire length of membrane is in place, peel-off the:release film diagonally while holding the
membrane tight: Firmly roll the membrane into-place to achieve°a bond.
Horizontal.seams should be minimum 3-inches, configured to shed water.. Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams in the course below. All over-granule end=lap's
shall be sealed.using either heat-welding or hot air welding techniques.
When installing at slopes.above 8:12; Allied Building Products Carp recommends back-nailing in the
overlap°area at the top of tl e'shee.t at 12-ioi h o.c.
For Valleys and Ridges: Cut underlayment into 4 to-6 foot lengths.Peel the release paper and center sheet
over valley or-ridge. Drape and press sheet into place, working from the center of the valley or ridge in
each direction. For valleys;apply the sheet-starting.atthe lowest point and work upward.
6.3.3 Tile Arib'lications(Tri-Built S%A HTTU Underlayment only):
Reference is made-to FRSA/TRI April 2012- (0442) Installation Manual and Table 1 herein, .using the
instructions noted above as guideline.
Tile, shall be loaded and staged in a manner that prevents the slippage and/or damage to th�
underlayment.
Exterior Researchand Design,,LLG ESaluatlon Report A42960:10.127R3
EertF!aate ofAuthoifzation#9503 F.1.16048-P6
Revision 3:10J08J2015
Page 4 of
I
I
I
I
i
I
I
i
y _ iER
TRIM Y�
5.64 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/.rRl April 2012 (04-12)
does not address wind.uplift resistance of all underlayment'systems beneath`foam-on the systems,where
the underlayment forms part of the load-path. The following wind uplift limitations apply to direct-deck
underlayment systems that are not addressed in':FRSA/TRI April Z012(04-12)and are_ used in foam on file
applications. Maximum Design Pressure is the result of testing for wind load resistance based on
allowable wind loads, and Teflects the ultimate passing pressure divided by 2(the 2 to 1 margin of safety
per FBC 1504.9 has.alread been applied), Referto FBC 1609 for determination of design wind pressures.p. Y . pp a• g p i
5.6.4.1 Maximum Design Pressure=45:0 osf
Deck: Min.15/32=inch plywood to meet project requirements to.satisfaction ofMj.
Primer: (Optional)ASTM.D41
Underlavment: Tri-RuiltS/A-WTTl1 llnderlavment=self-adhered_
i
li
I
i
i
III
I
� ' I
TPJNITYIERD
7. BuiLomG PERMIT REQUIREMENTS:
I
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the:installation of
this product. j
8. MANUFAGTURINOPLANTS.
Contact the noted QA agency for information on product locations covered for F.A.C:Rule 9N-3 QA requirements: {
9. QUALITY ASSURANCE ENTITY; .
UL,LLC—QUA9625;(914)g78-3406;;k.chancellor@us:ul.com
-ENQ OF EVA.LUATION REPORT=
I
' I
I �
�I
II
I
I
I�
"rior'Resear6 and-Design,LLC.
Evaluation Report A42960.10:12 R3
i
eeiWi[ate of Autharization#9503 FL16048 R3
.Revision 3c 10/08/2015 i
page 5 of 51