HomeMy WebLinkAboutBuillding plans2"
O.H.
Finish Columns With
5/8" thick cut coral
finished stucco bands
5/8" thick x 8% cut
coral finished stucco bands
12
4 1 SLOPE
COVERED
PORCH
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11651.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment Installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced d o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
5/8" thick x 8"W cut
coral finished stucco bands
LEFT ELEVATION
SCALE: 1/4" = 1'-0"
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 411651.12
26 ga. 5v crimp metal roofing attached to plywood deck using 49 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 Ib felt underlayment Installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" o.c. at all laps and two staggered rows 12" o.s> -n field. Attach
deck tc trusses using attachment detail on this sheet
------ ------------------
RIGHT ELEVATION
thick light textured
stucco on typical concrete
block construction
SCALE: 1/4" = Y-O"
Product Approval Submittal Affidavit
Opening Schedule Swing Doors, Overhead Doors. Sliding Doors,
Windows & Skylights
Opening
Type
NOA/FL
NUMBER
Product
Model #
Manufacturer
Glass
Attachment method
SaTration
zp
Date
Design Pressure
of Approved Tests
PP
1,2,3
FLU 11499.2
Single Hung
Series 185
Mi Windows
and doors
i U x core mi n et on at max
from CM corner end L ox. tl oraa%'tor thro �gl f �uck into solid
filled CMU well maintaining min 2.5" edge distance in strict adherence
to the product a royal.
+ 60 sf
p
A
16-0330.02
Overhead
Garage Door
g
Model 824/811
9'-4" max Width
IL'-o" max hei ht
g
DAB
w x uc to <en<rete ae mt a un
g ps �e yen. awns 3ie' x c Hiiu HLC Sleeve wchon et e' o.<.
ah 1.1 ' do w r♦♦ yrth inn. 1' edge deteau. Iwtal�t lek to hock
re in 5/u' x i 5/e rill thread la& .cress m ex ec et mmntening
M d 1.5' edge dutanee - GC to atrwtlp adhere to product approval
rnide l/IL' uMnut eeaher on rdler aher4
10-9-21
+ 50.0/-60.0 psf
B
FLU I6614.1
Fiberglass
Deal n Pro/
smooth Pro
Jeld-Wen
Elco 1/4" dra. tapcon with min 1.2S" embedment at 3" max
from corners and 11.5" o.c. max thereafter in head and jambs.
+ 50.0 PSF
C
FLU 15332.2
Glass
Door
Series 420
MI Windows
andoors
d d
at axShding
oebeac. corner and �oca ratherearternhroug
PT Suck into solid filled CMU wall maintaining min 2.5' edge istance
in strict adherence to the product approval.
+ 48.2 PSF
-
Product
NOA/FL
NUMBER
Model #
Manufacturer
Attachment Method
E Spi ation
Date
De Pressuren P ssTu
oPProved
Mullions
FLU 15353.8
CM-18531
vertical mullion
Mi Windows
and doors
For CMU use (2) 1/4" x 2 3/4' tapeons with min 1 1/4" embedment
penetration into each Mull Clip. Attach mull to clip using 14) u10 x 1.25"
self tapping screw& per clip as shown in product approval.
+ 118.9 PSF
_
Roof
FLU 11451.12
SV Crimp
p
Metal Roofing
Gulf Coast Supply
and manufacturing
26 ga. 5v crimp metal roofing attached to plywood deck using a9 x 1.5"
wood screws with self sealing washer at 12" o.c. max Vacing over ASTM D
Itypa 2) 30 lb felt underlayment installed with min. 4 side laps and C' and
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 4' o.cat all laps and two staigered rows 12" o.c. in field. Attach
'
deck to trusees using attachment detai on roof plan
- 108.5 PSF
Siding
Stucco on Block
Soffit
FLU 12198.3
Model T4 12" vented
Vinyl Soffit
Kaycan
Install using 2" x 2" battens at 6" o.c. screwed to soffit framing using
#8 x 3" wood screws at each truss. Install soffit to battens using
0,12' die. x 1.5' Iona ring shank nails with 3/8" dia, d.
+55,0/-35.0
PSF
Hurricane
Panels
Flu 15016.2
24 Gauge
Storm Panels
Global Protection
Products LLC
Install using 1/2" dia. solid set lead anchors with 1/4" dia.-20 x 1.5"
long 55 screw head combo. with Neoprene washer at 12 1/2" o.c.
along the bottom and 13" o.c, at the top
+ 45.0 PSF
I have reviewed the above and approved it by my seal below. ( Architect or Engineer of Record )
II EGRESI
5/8" thick light textured
stucco on typical concrete
- -block construction
12
SLOPE 1,4
Gulf Coast Supply and MFG Sv Crimp Metal roofing FL 411461.12
26 ge. Sv crimp metal roofing attached to plywood deck using #9 x I.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" o.c. at all laps and two staggered rows 12" o. In field. Attach
deck to trusses using attachment detail on this sheet
5/8' thick light textured
5/8" thick x 8"W cut stucco on typical concrete
coral finished stucco bands block construction
REAR ELEVATION
12
COPE 4
ST. LtiCTF couwl'??L ,n W nit fc7n
R f; V [E)i' E D FOR CO
REVIEr'WLD B
DATE 6
PLANS A -ND PF_RNUT't LTST BE KEPT ON JOB
OR NO INSPECTION WILL BE MADE.
2,
H
COVERED LED FASTENERS OR ATTACNMENIS
PORCH C NC, E THE RESPONSIBILITY OF IKE
CONTRACTOR OF RECORD
SCALE: 1/4" = 1'-0"
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11651.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM 1)(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
EGRESS
ALL MANUFACTURES LABLES SSVaG HOWING
U FA�� AND
MUST
REMAIN ON ALL DOORS AND WINDOWS
UNRL INSp[.O[pNS ARE AF'PROVED
ApESgUPB�IECT TO ANY CORRECTIONSNS AND ALL PROPOSED ORK
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE CODES,
TERMITE TREATMENT, 6EQUIRED
1/8" Thick cut coral stucco over paper
backed wire lath nailed to substrate through
one layer of IS lb felt using Bid nails. Substrate
to be 19/32" COX Plywood nailed at 6" o.c,
in field and edges with IOd ring shank galvanized
nails into truss webbing.
12
SLOPE 14
I=II
ICI,
ill
III
III
ITV ill III II�II
5/8" thick x 8% cut 2'-2"
coral finished stucco bands FRONT ELEVATION
SCALE: 1/4" = 1'-0"
ALL CONTRACTOR WARRANTIES BEGIN WHEN THE CLOSING
OCCURS BETWEEN THE BUYER AND WYNNE BUILDING CORP.
I/2" drywall ceiling on truss bottom cord AND WILL CONTINUE FOR ONE YEAR FROM THAT DATE
2" x 4" top plate
1/2" drywall on
2" x 4" studs at 1C o.c.
boss -board I 11 / 2" x 4" P.T- bottom plate
\ 4" concrete slab with fibermesh OR
6'x4" #10/10 WWM on 6 and Visqueen over
clean compacted termite treated fill
Interior NOn-Bedrinq Fdrtltion
nts
PERMITTING INFORMATION (FORM 100)
Florida Building Code Residential: 5th Edition and ASCE 1-10 for Wind Loading
Building Design is: Enclosed Risk Categorg: II Wind Velocity: 145 mph ultimate
Mean Roof Height:__I�F-O" Roof Pitch: 4:12
Internal Pressure Coefficient: ±0.18
SubJectability to damage from: Weathering: Negligible Termites: Vero Heavu
Width of Roof End Zone: 3'-4" Wind Speed: I45 mph ultimate
Wind Exposure Classification: C
HIP RppoP 1:1
TO L:11 PITCH
41.21
x O.L = 0.12L
Adjustment factor for Exposure Height: ASO design
Load Combination: ASCE 1-10 Section 2.4 DL+LL; DL+O.LWL; O.LDL+O.LIUL
Components t Cladding Wind Pressure (NET) Roof Zone: 1. +20A/-32.4 psf
Roof Zone: 2. +20.4/-51.0 psf
Roof Zone: 3. +20.4/-84.0 psf
Components t Cladding Wall End Zone Width: 3'-,4"
Components t Cladding Wind Pressure (NET) Wall Zone: 4. +35.8/-38.1 psf
= Roof Zone I
Wall Zone: 5. +35.8/-41.8 psf
Walla Zone 4
Components t Cladding Wind Pressure (NET) on Garage Door. +32.0/-40.3oaf
Shear Walls Considered for Structure? Yes
Continuous Load Path Provided?
= Roof Zone 2
es
Walls Zone 5
Are Components an Cladding Det� Provided? Yes
END ZONE
Minimum Soil Bearing Pressure:2,500 psi, Presumptive: X By Test: psi
This Building Shall Have the Following:
M= Corner Zones
APPROVED SHUTTERS: X IMPACT GLASS: BOTH: NEITHER:
Roof Zone 3
ROOF LIVE LOAD: 31 psf ROOF DEAD LOAD: 10 psf
FLOOR LIVE LOAD: _±5- pef FLOOR DEAD LOAD: 1Ooaf
JOB ADDRESS:
"FLOOR CLAN
4"
/�» n C l I DnC T r�t—T n I
I I I =C: IDL./Hi_C I/`I —V
I. Contractor to verify ALL notes and dimensions prior to 34" high by 4" diameter
steel crash post. Floor
proceeding With Work. Mange with 4 - 3/8"
2. Contractor to STRICTLY enforce ALL OSHA Requirements. expansion bolts Into
3. ALL Lumber to be used as Beam, Rafters, etc... to have slag (3/8"t 50 ksi steel plate)
a minimum 1,400 P.S.I. fiber stress. 6°
4. No dissimilar metals to touch. _ _ _ _ _ _ 2r,"
or-L.ui uirl!� uv Lne i vuvwiry: ( i LJ 4, iN I" x 6" P.T. BMasonry Beam
uck nailed to
block with case hardened Wads /
prior to door attachment
Drywall
19. ALL ceramic the surfaces Installed shall conform to ASTM A108.1 thru 4108.6,
A108.1, A118.1, A118.3, A136.1 and A137.1
20. Cement, fiber —cement or glass mat gypsum backers in accordance with ASTM
C1288, C1325, OR C1118 and Installed I.A.W. manufacturers recommendations shall
be used as backer for the wall the in tub areas and wall panels In shower areas.
21. Insulation Including facings such as retarders or vapor permeable members Installed
within floor —ceiling assemblies, roof —ceiling assemblies, wall, crawl spaces and attics
shall have a flame spread Index not to exceed 25 with an accompan,ylng smoke
developed Index not to exceed 450 when tested in accordance with ASTM E 84.
Insulation shall comply with F.B.C. R316.
Gulf Coast Supply and MPG 5v Crimp Metal roofing FL #IIG51.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1,5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and (" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank Wads
spaced 6 o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet �
Simpson HETA 20 or equal
hurricane anchor at each truss 12
with (10) IOd x I I/2" nails
( 24" o.c.) supporting Max. 4
181016s. uplift
Aluminum Drip —
Edge t Fascia
2" x 6"
Kaycen full a vent vinyl soffit installed
using I/8" dia shank x 15" long gale.
roofing nails with 3/8" die. head per
product approval —see chart sheet #I
5/8" thick light textured
stucco on typical concrete \ -7
block construction °p
4
5 bar vert. w/
30" overlap
at each filled cell
Grade
Wood
TYPICAL SECTION
PRE-ENGINEERED TRUSSES
at 24"o.c. TYPICAL
(shop drawings by manufacturer)
\
R-30 blown fiberglass
in bottom chord of trusses
-I/2" drywall with smooth finish
Two rows of beam block filled with concrete
_and (I) #5 bar cont. in each row. Substitute
precast lintel filled with concrete and (U tt5
bar Cont. for bottom row over openings
I/2" drywall over I" x furringg
strips a� IL" o.c. with R4.1 fi-foil
-insulation on typical 8" Block walls
All drywall to be installed per FBC R702.3.1
and shall meet all pertaining ASTM codes.
Mortar to be Type "M" only proportioned per FBC R601.1
and Mortar Jonts shall comply with FBC R607.2.1.
Provide Dur-O-Rock at all wet areas (ex. showers, tubs etc...)
Fill cell with concrete and
(D #5 bar vert. (typical).
Max. spacing shall not exceed
48" unless otherwise noted
see foundation plan notes for
spacing at openings
4" concrete slab with fibermesh OR
6"xb" #10/10 WWM on 6 mil Yisqueen over
clean compacted termite treated fell
14" x 14" Concrete footing
with (2) 45 bars cont, and 45
transverse bare at 48" o,c.
Scale I/2" = I'—O"
N.T.S
AREA CALCULATIONS
Living A/C = 1120 sq. ft.
Back Porch Total = 210 sq. ft.
Garage = 311 sq. ft.
Entry = 28 sq. ft.
Total Under Roof= 2215 sq. ft.
Total Cubic Ft = 13,7160
2" VTR
JL
Attach buck to block wall with
I
I
I/4" dia. Elco conc screws with min.
I
I I/4" penetration at 12" o.c. max
I
and 4" max from each corner thru
Exterior Pace 2" x 6" PT $uck
21' VTR
of wall
arias
/ I I
I
I
Master I
s•
Lev.
I
I
48 Wood stress thru jamb int$be�;
I
at each hinge and IS" o.c. max and'Z.
Detail at Door Prior to door attachment Lev.
I
4"
2" VTR
NTS we
I JIL
INSTALL YULKEM BLOCK SEALANT
ON ALL JAMB, HEADER, AND
I
SILL BLOCK PRIOR TO BUCK
2.
Shur.
�
3" I
INSTALLATION
Kit Sink
I
Install windows thru buck into Kitchen
2
I
I
block with 3/16" tap —con with
I I/2" penetration at 6" o.c. max.
I
Prom each corner and 20." o.c. max
I
thereafter at .Iambs and 20" ac. max.
Lev.
Exterior face at head and sill per product approval
of Well � Buck to be I" x 4" PT
Varies wwaaarmuffil
\
W.C.
Detail at Windows
Bath tt2
I"x4" P.T. Buck nailed to
block with case hardened nails
prior to window attachment
NTS PI IIMRI\Ir,
Install SGD thru buck into
block with 3/I6" tap -con with
I I/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at head per product approval
O10 Use 3/I6" tap -con with
I I/2" penetration at 6" o.c. max.
from each corner and 20" o.c. max
thereaFter at sill per product approval
I" x 6" P.T. Buck nailed to
block with case hardened nails
Head prior to door attachment \
fixed door
sliding door
Masonry Wall
I v2„
Bottom Track Typical Flooring
Sill Install SGD thru buck into
block with 3/I6" tap -con with
Door D� t a l l I I/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
At Masonry Wall NTS thereafter at Jambs per product approval) a m b
Window
Schedule
Mark
Size
Rough Open.
Window Description
PRESSURE ZONE
I.
4'-5%'x 5'^3%"
54%"x 63%4"
Single Hung
ZONE 4
2.
6'-2%"x 5'^3 %a"
15" x G3 %,"
Single Hung
ZONE 4
3,
2'-2" x 3'-2'h"
21%2"x 3851s'
Single Hung
ZONE 4
x 5'-3%"
38" x 1.3'14'
Single Hung
ZONE 4
5.
4'-5%'x 4'^2%"
54111x 54Ye"
Single Hung
ZONE 4
ALL Windows to be aluminum windows w/ tint
and mullions per elevations.
ALL windows to withstand pressures In permit Info box on sheet I
ALL windows In bathrooms to be tempered
All rough opening dimensions to be verified by contractor
with manufacturers specs prior to construction
Door Schedule
Mark
Size
Rough Opening
Door Description
PRESSURE ZONE
A
9'-0" X 1'-O"
108" x 84"
Overhead Geroge Door
ZONE 4
B
3'-0" X
41"%4' x 83%,"
Panel -Inswing
ZONE 4
C
L'-O" X L'^e'
l4" x 81 %" � ;u"°`„`°"
-Fiberglass
Sliding Glass Door
ZONE 4
D
2'-0" X 4'-8"
Solid Core —Wood — G—Panel -Bi—Fold Finished 24" x 81 %,"
E
2'-L" X 4'-8"
Solid Core -Wood - 4-Panel
F
5'-O" X 6'-8"
Solid Cora -Wood - 6-Panel - Bi-Fold
G
2'-8" x L'-8" x I N"
Solid Core Wood, Steel, or Meaonite Door
H
2'-e" X G'-8'
Solid Core -Wood - 4-Panel
J
2'-4" X G'-e"
Solid Core -Wood - 6-Panel - Bi-Fold
ALL Exterior doors to withstand pressures stated In permit Info
box on sheet #I
GARAGE DOOR SPECIFIED IN PRODUCT APPROVAL FORM AND SHALL
WITHSTAND THE PRESSURES STATED IN PERMIT INFO BOX ON SHEET ttl
All rough opening dimensions to be verified by contractor
with manufacturers specs prior to construction
Shwr.
3'
c.o. Ta Septic
RISER
NTS
Braden It
Braden ,41,4, P,4
Architects
-Planners
-4I1
S.E. Coconut Avenue
Tel :
(1-12) 281-8288
Fax
(172) 287-8253
E—mail:
bradenala9comcast.net
Stuart. FL
3-4996 #AAC000032
m
C
c
r
10'-6"
_ Wgnne Building Corp.
THE ROYALE
Spanish Lakes
St. Lucie County Florida
21'-O"
35'-O"
MODEL:
GARAGE
RIGHT
14'-O"
O
Date Drawn
S—q—IZ
Drawn by:
C.C.L,I.
Checked by:
D.R.B.
Revisions
Sheet Comm #
21 12-101
OF 5
Thickness
Location
Orientation
Framing
Member
Max, spacing
ners
of fasteners
Nall sizing options for
drywall
Spacing
Maximum
installation of into
wood framing members
Nails
Screws
2" x min, thickness
Ceding
Perpendicular
24"
�"
12"
13ga 13/8'OlRong with 19/64" head
0.098" diameter x I I/4" long
11
/2
annular -ringed or Sd cooler nail
Walls
Either
IL
8
" 16
0.080" dia. 15/8" long with
Direction
I5/64" head
OR
Ggpsum board Wad 0.086" dia.
x 15/8" with 9/32" head.
Ceiling
Perpendicular
24"
T,
12"
13ga 15/8" long with 19/64" head
0.098" dia�Rter x 13/8" long
annular -ringed or bd cooler nail
/
Walls
Either
16"
8'
16
0.092" dia. I 1/8" long with
Direction
I/4" head
OR
Ggpaum board nail 0.0915" dia.
x I 1/8" with IR/64" head.
STRU
I. ALL FOOTING ARE DESIGNED
FOR A MINIMUM
OF 2,500 PSF SOIL
9. SLOPE ALL PORCH SLABS, COVERED WALK, ETC. AWAY
BEARING CAPACITY. IF ANY
SUB -SOIL, MUCK
OR NON -UNIFORM
FROM HOUSE TO DRAINS (IF PROVIDED) PER PLANS
CONDITIONS EXIST, REPORT
TO ARCHITECT
AND OBTAIN
PROPER ENGINEERING DATA
FOR DESIGN.
2. ALL SLABS AND FOOTINGS TO
BE A MINIMUM
2,500 PSI AT 28 DAYS
10. DESIGN LOADS ARE AS FOLLOWS:
ROOF (DL+LL) = 41 PSF
ALL COLUMNS, FILLED CELLS,
BE 3000 PSI OR 4,000 PSI
AND BEAMS SHALL BE MIN. 3000 PSI
GROUT MIX AT 28 DAYS
WIND VELOCITY = PER PERMIT INFO BOX ON SHEET 41
EXPOSURE ="C"
3.
POISON SOIL AND COVER W/ 6 MIL. VISQUEEN WITHIN 24 HOURS. NO
SOIL POISONING TO BE ACCOMPLISHED OUTSIDE OF FOUNDATION.
11.
ALL REINFORCING STEEL SHALL BE GRADE 60, MEETING ASTM A-16, t
4
GROUND FLOOR SLAB TO BE A MINIMUM 4" THICK W/ 6X6 10/10
A-35 SPECIFICATIONS. ALL ANCHOR TO BE A - 301 STEEL.
WELDED WIRE MESH REINFORCING ON 6 MIL. POLYETHYLENE VAPOR
12
BARRIER TERMITE TREATED, CLEAN MACHINE COMPACTED FILL
ALL DOWELS, SLEEVES, CONDUITS, INSERTS, BLOCKOUTS, ANCHOR
(MINIMUM 95% DENSITY). LAP POLYETHYLENE 12 MINIMUM. FI$ERMESH
BOLTS AND FRAMES SHALL BE IN PLACE PRIOR TO POURING CONCRETE.
MIX MAY BE SUBSTITUTED FOR WELDED WIRE MESH.
FOR OPENINGS AND SPECIAL FEATURES OMITTED ON THESE PLANS,
SEE ARCHITECTURAL OR MECHANICAL PLANS WHERE APPLICABLE,
5-
LOT TO BE CLEARED OF ALL SMALL PLANT GROWTH AND DEBRIS
BEFORE FILL IS BROUGHT IN. FILL TO BE SPREAD IN 12" LAYERS AND
MACHINE COMPACTED TO A MINIMUM OF 2500 PSI IN AREA OF
1 3.
MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS:
BUILDING CONSTRUCTION
FOOTING: 3"
BEAMS: 1-1/2"
6.
TEST FOR FILL COMPACTION MINIMUMS PRIOR TO FORMING SLAB.
14"
LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS.
-1•
GENERAL CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND
DIMENSIONS. BRING ANY DISCREPANCIES OR OMISSIONS TO THE
15.
USE STRUCTURAL GRADE WOOD WITH A MINIMUM Fb OF 1600 PSI
ATTENTION OF THE ARCHITECT.
16.
ALL STANDARD LUMBER SHALL BE SYP WITH A MINIMUM Fb OF 1000
8•
GARAGE FLOORS TO BE SMOOTH TROWEL FINISH (SLOPPED PER
PSI OF NO.2 SOUTHERN PINE, UNLESS NOTED OTHERWISE.
FOUNDATION PLAN). PROVIDE 1-1/2" RECESS FOR OVERHEAD DOOR
FOUNDATION FL/4N
17• ALL LUMBER IN CONTACT WITH ANY CONCRETE OR MASONRY SHALL BE
PRESSURE TREATED. FASTENERS TO HAVE MIN. G185 RATING.
I. Any changes to plans must be submitted to the architect
for approval before proceeding With construction.
2. Contractor shall be responsible for verification of all
notation and dimensions before starting construction.
3. Soil conditions assumed to be 2500 psf. Should any other conditions be
encountered, the architect shall be notified in Writing for revision
4. Verify all recess thickness at showers, tile, etc....
S. Contractor to provide filled cell with concrete and 1 45 bar Vert. at -48"
0.C. max. Provide (1) filled cell On each Side Of openings upp to 5'-11" wide.
Provide (2) filled cells on each side of openings from 6'-O" to 9'-11"
and Provide (3) filled cells on each side of openings from 10'-0" and up
Contractor to see plans for any other condition used. Foundation walls
shall have filled cells at 2-f" o.c. unless otherwise noted (see section)
6. Contractor to provide for Form Board Survey - Form Board Survey
to be provided to Truss Company prior to truss construction
1. Contractor to provide for soil test prior to construction and provide
a copy of soil test to architect for review prior to construction
8. ALL Reinforcing steel shall be grade �0, meeting ASTM A-l( and
A-35 specifications. ALL Anchors to be A-30�1 steel.
9. Provide a minimum of 3" concrete protection at footings and
1-1/2" concrete protection at beams for ALL reinforcing bars,
45 bar Vert. w/SEE TYPICAL
30" overlap ECTIONS
at each filled cell
4" concrete slab with fibermesh OR
6"x6" #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
Grade
14"w x 14"d concrete monolithic
footing with (2) #5 bars cont.
14"
f I TYPICAL FOOTING DETAIL
SCALE 1/2"
4" concrete slab with fibermesh OR
6 x6 #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
#5 bar Cont.
Step per
foundation plan
r
N ^ "
10" (2) 3*5 bars cont. bottom steel
12"
==DETAIL AT GARAGE STEPDOWN
SCALE 1/2" = 1'-0"
12" x 12" concrete column
block filled with concrete
and (2) #-1 bars vert. tied
into lintels above Verifg house slab
height in field
Top of Tooter
16" below finished floor -
�IIIIIIII III II I IIII- ...
30"x30"AC concrete
IIT II I = column footing with (4)
=� 45 bars each way
ii -IIII I
3
30"
COLUMN FOOTING DETAIL
SCALE 1/2" = I'-O"
Thicken edge to 8"x8"
with concrete and
one #5 bar continuous
GRADE\ \
SCALE: 1/4" = 1'-0"
FOOTING
SCHEDULE
Mark
Size
Description
FI
14"W
x 14"D
MONOLITHIC FOOTING
WITH 2 #5 BARS CONTINUOUS
F
12"W
X 12"D
MONOLITHIC FOOTING
WITH (2) #5 BARS CONTINUOUS
30"
x 30" x 16"D
COLUMN FOOTING WITH (4) 3*5 BARS EACH WAY
F
8"W
x e"D
THICKEN SLAB EDGE
WITH 1 #5 BAR CONTINUOUS
F5
14"W
With
x 14"D
Curb at Garage
MONOLITHIC FOOTING
WITH 2 #5 BARS CONTINUOUS - CURB 9 0'-0"
4" concrete slab with fibermesh OR
6"x6" #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
PORCH SLAB EDGE DETAIL
#5 bar vert. w/
30" overlap
at each filled cell
Adjust curb height
based on gar. floor
slope.
#5 bar in curb \
Grade
I
SCALE 1/2" = 1'-0"
--,,SEE TYPICAL
SECTIONS
4" concrete slab with fibermesh OR
Vxb" #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
-n" e F F
�<_14"w x 14"d concrete monolithic
rooting with (2) #5 bars cont.
GARAGE CURB DETAIL
2" x 6"
PT wood secured
with \
3/8"dia.
x 6" anchor bolt
at 18" o.c.
overhead door track secured to
wood
jamb per manufacturer's product
approval
Garage
Door Jamb
Detall
GARAGE
DOOR TO WITHSTAND PRESSURES STATED
j� T S
IN PERMIT
INFO BOX ON
SHEET #I. SEE PRODUCT
APPROVAL FORM FOR MANUFACTURER MAKE AND MODEL.
Termite Protection for New
Construction.
Soil treatment used for subterranean termite prevention
inside the foundation perimeter shall be done after all
excavation, backfilling and compaction is complete.
If soil area is disturbed after initial chemical soil treatment
area shall be re -treated with a chemical soil treatment
including spaces boxed or framed.
Treatment must be in accordance with the rules and laws
established by the Florida Department of Agriculture and
consumer services.
Protective sleeves around metallic piping penetrating
concrete slab on grade floors shall not be of cellulose
containing materials and shall receive application of
termicide in annular space between sleeve and pipe.
Filled Cell Masonry Column With One
45 From Footing To Tie Beam
Conc. Fill To Be 3000 PSI
See Floor Plan For Location
Single Filled Cell Column
NTS
Filled Cell Masonry Column With One
45 From Footing To Beam Each.
Conc. Fill To Be 3000 PSI
See Floor Plan For Location
Double Fille
Cell Column
NTS
0
O i
0
I
0
210
21'-0"
10'-C
1 x 12" concrete column block filled
with ncrete and (2) 47 bars vert. teed
\ _ Into lintels above
�— — — — — a IJIJ Luu _i_i_ _�i_i_- i=1UIL°JI I Il
T �� — i — — — — PI
Filled cell under I FI girder above 0
U1 Rear Porch Slab to
i f� be poured separately
Q from House Slab. L
N \ O r N 2 Thicken footing to
I ' 2
FI Rear Patio/Slab to
be flush with bottom of
sliding door recess.
1 Slope I"
IIi
i (I
i l
I
i
I FI
�I
I
I
4 w x 14 d x 4 L
under filled cell
Q Q under girder bearing. I
J
FI I
I
I
I
i
I
I
4" concrete slab with fibermesh OR /
CxC 1*10/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill
FI
a
A (�L)
I
to
---T
UIRED
><
_ � I
I
Io
I
Oil
I
O
o
O _0_1
--— — — — — —— —
I
I
I \-4"O Steel Ballard
See detail on this sheet
I
I I
I 4" concrete slab with fibermesh OR
l ox6" #10/10 WWM on L mil Visqueen ver
I clean compacted termite treated fill
O I
I I
I 12 N I
I-
-_L
0 i (L `=f
w I I
o I Recess for
Garage Door_ — _ _ J
2'-2" 2'-8" 2'-8" 3'_6" 9'-01,
s
R00F SHEETING
ATTACHMENT DETAIL
I. Minimum Nail Size = 8d ring shank (min. 2.5" long)
2. Minimum Screw Size = 48 x 2"
3. Minimum Sheathing Thickness 19/32" CDX Plywood
4. Use nails or screws based on ressure for roof stated
in permit info box on these plans for zone 3
Area
Edge
Field
Fastener
Pressure
MKe
Zone 1
6"
6"
8d ring shank
45 psf
Zone 2
4"
6"
8d ring shank
16 psf
Zone 3
4"
shank Sd ring shank
84 psf
** Zone 3a
6"
6"
it8 wood screw
112.5 psf
** Use nails or screws based on pres ure for roof stated
in permit info box on these plans for zone 3
Concrete
/ Lintel
C olumn
Vi _ erlfy with Plan _
Rebar
to L.Intel
Provide #5 bare with min. 48 bar
diameters overlap Into beam. Tie
filled cell steel into continuous
beam block steel
Provide Cast -Crete:
8U8-OB/OT precast `-
lintel set mortar
Min. 8" Bearing
12 "x 12"
Column Block
�#1
Rebar
ROOF F L 4 N Scale : 1/2" = I'-O"
Provide #5 bar set in pre -cast
lintel into beam where length of the opening calla for it. - O t 1'-0"
1 h d t h h
Provide PT Buck
attached per jamb
latads into filled ci
4" Pre -cast
Sill
ver angs a un ess of erwise note on is s set
— Roof pitch at 4:12 unless otherwise noted on this sheet
— Truss shop drawings to be r of h provided b manufacturer
— Any changes to this plan shall be submitted to the
architect for approval in writing prior to starting construction.
— ALL TRUSS TO TRUSS CONNECTIONS BY
TRUSS MANUFACTURER
— Architect to review Truss Shop Drawings Prior
to construction for layout and Uplift verification
Poured Filled Cell - Contractor to provide for Form Board Survey and to provide
Form Board Survey to Truss Company prior to truss construc0
N
Provide #5 bars with min. 48 bar
diameters overlap in filled call. Tie
filled cell steel into continuous UJ
rooter steel.
s.n^
CBS WALL Scale: I/2" = I'-o"
SINGLE PLY REAR GIRDER TRUSS
—Nail 2" x 4" blocking to vart. leg of
truss with IOd x 1.5 nails at 4" o.c.
c Install Simpson MGT into wall usingg
5/8" dual threaded rod set min. 12"
into wet beam and (22) IOd nails into truss
48 Bar Dia. TRUSS BLOCKING DETAIL
Min. overlap `': ` AT GIRDER STRAPPING
AT CENTER BEARING POINT
�4 ttachment
NTS
1/8" thick light textured stucco installed per
ASTM C 924 over ASTM D type 2 paper backed
wire lath nailed to substrate through one layer of
ASTM D Tyype 2 felt paper using 8d nails. Substrate
to be 19/32' COX Plywood nailed at 6" o.c. in field
and edges with IOd ring shank nails into studs.
Gulf Coast Supply and MPG 5v Crimp Metal roofing FL 411661.12
26 ga. 5v crimp metal roofing attached to plywood deck using 49 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb Felt underlayment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6 o.c. nt all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet \
Additional recast Lintel
#5 be
r `"::•; 7 r', = "::'y CLEAR
Linte1 l
Length
Bar
Length
Clear
Span
u "
A
Bars
u u
B
Bars
2
1
2'-10"
2'-8"
I'-6"
#3
none
1 1 1 1 1 1
3'-6"
3'-4"
2'-2"
2,#3
none
8lw8-OB/IT 81"1 81"1
Addtional
4'-0"
3'-10"
2'-8"
243
none
#5 bars
_,...r
CLEAR'�''':;? ':+=
4'-6"
4'-4"
3'-2"
2,43
none
'�'.•;�'.270ne Row of "H"
5'-4"
5'-2"
4'-O"
2,43
none
Block Above
%*
5'-10"
5'-8"
4'-6"
2,44
none
*' h°
Precast Lintel
1 Additional i
5'-4"
2,#4
none
#5
1'-O"
6 -2'
2 #5
none
SFIL-IB/IT BFIL-IB/2T
�'-O"
2A5
none
NOTas:-10"
ALL reinforcing steel is grade 60.
I. min, coverage of steel=1.5"
2. min. bearing required a ea. end=8"
3. standard for reinf. steel=ASTM A615
TYPICAL LINTEL SECTION
( PRECAST CONCRETE )
LINTEL
SCHEDULE
window
Rows of
Max
Max
Max.
or Dow
He Block
Gravitg
Uplift
Lateral
Mark
Unit
Lintel
Cast -Crete
Above
Bottom
Size
Top
eJ12e
Load
Load
Load
Width
Size
Specification
"
Steel
steel
(PLF)
(PLF)
(PLF)
L22
2'-2"
3'-6"
BFS-OBAT
I
#5
3069
mvi
1024
Simpson HETA 20 or equal
hurricane anchor at each truss
with (10) IOd x 1 1/2" nails -
( 24" o.c.) supporting Max.
18101ba. uplift
Aluminum Drip _
Edge t Fascia 1/2" thick stucco on 3/8" hi —rib lath
2„T14 attached to horizontal and vertical wood
framing with Haile or staples to provide
2" x 6" Sub-Fasci no lass than I-3/4" penetration into
horizontal wood framing and 3/4" panetraGon
into vertical wood framing members
Kagcan full o vent vii soffit installed
using I/8" die shank x 15" long gal"'.
rooting nails with 3/8" dia. head per _
product approval — see chart sheet #1
5/8" thick light textured
12" x 12" concrete column stucco on typical concrete
block filled with concrete block construction
and (2) #1 bars vert. tied Varies - see plan
into lintels above 45 bar Vert. w/
thicken edge to 8"x8" 30" overlap
with concrete and at each filled cell
one #5 bar continuous -\
BEYOND WH
Rear Patio/Slab to
be flush with bottom of
sliding door recess.
12
4
Aluminum Drip
Edge E Fascia
Poured Co
concrete E
Poured Concret
concrete block i
Concrete,
Manufacture
Flash and Counter
flash
Nail ledger to
gable end truss
with (2) IOd is
at each web
Top of rooter
19" below finished floor
V
ONE
ur�iee'®ae-.
Step per foundation plan
Slope per foundation plan 'r
Flush Mounted Shutter Detail
klummum Panel
sizes per manufacturer
See 7gpcai Stud Detail-
1/8' x 3/32" Wing Nut w/
appropriate washer and sppacing
per manufacturer's Datails
I
Stud Detail
Stud w/ Die Cast Zinc NTs
Nickel Plated Wing Nut
nts
Brace Gable end
with 2" x 4" SYP 42
8ft back nailed to bottom
of top chords using (2) IOd
nails at each truss
PRE-ENGINEERED WOOD TRUS
® 24"o.c. TYPICAL
( shop drawings bg manufacturer )
�R-30 blown fiberglass
in bottom chord of trusses
-1/2" drywall with smooth finish
Two rows of beam block filled with concrete
_and (U #5 bar Cont. in each row. Substitute
precast lintel filled with concrete and (U #5
bar Cont. for bottom row over openings
1/2" drywall over I" x furringg
strips at 16" o.c. with R4.1 fl-foll
-insulation on typical 8" Block walls
All drywall to be installed per FBC R102.3.1
and shall meet all pertaining ASTM codes.
Mortar to be Type "M" only proportioned per FBC R6o1.I
and Mortar joints shall comp with FBC i2601.2.1.
Provide Dur-O-Rock at all wet areas (ex. showers, tubs etc...)
Fill cell with concrete and
(1) #5 bar vent. (typical).
-Max. spacing shall not exceed
48" unless otherwise noted
see foundation plan notes for
spacing at openings
9" concrete slab with fibermesh OR
Ox6" 410/10 WWM on 6 and Visqueen over
clean compacted termite treated fill
IIIIIIIEE1
II—Ul11IIIIIIIIIIII_i-
14" F I
Ical S&ctlon at Front Forch
Scale : 1/2" = 1'-0"
Braden It Braden AIA, FA
Architects - Planners
411 S.E. Coconut Avenue
Tel : (112) 281-8258
Fax : (172) 281-8283
E-mail: bradenaia5comcast.net
Stuart_ FL 34996 #AAC000032
Strap truss to wall using Simpson MGT with Simson HETA 20
5/8" dla. threaded rod with min 12" embedment hurricane anchor at each truss
into beam either wet set or in epoxy with
(22) IOd nails into truss. Add blocking to ( 24" o.c.) stportin Max.
truss leg per detail on this sheet 1810 lbs. uplift
ETA 20
L908
L90B
100E
v
(L
� N
o
I
BI
L45
BI
BI
L60
BI
BI
BI BI
2"
T.H.
L45 B
/AULTED /RE �-
SLOPE
—p-�
BI
I � ~
. u)
0
W N �
l�
BI L31
L45 B 1
, m:m�
X//
Gulf Coast Supply and MFG 5v Crimp Metal roofin(
26 ga. 5v crimp metal roofing attached to plywood
wood screws with self sealing washer at 12" o.c. max
FL #11151.12 12
eck using #9 x 1.5"
spacing over ASTM D SLOPE 4
laps fastened with corrosion resistant tin caps and
spaced 6" o.c. at all laps and two staggered rows I
deck to trusses using attachment detail on this sheet
th 1.25" ring shank nails
o.c. in field. Attach BI
Lu J'
22" x 54"
17 Attic Access i
L31 B I qO�
I I
/
\ I
\I
I
I
z I
� I
I
i
BI j �R/A j
I
48"
8' :12" MAX
I L31
U!
!�
L31
OB
12
BI
BI
N
`r
BI
L90B
BI
41 SLOPELII
I
•N
Wynne Building Corp.
THE ROYALE
Spanish Lakes
St. Lucie County Florida
ETA 20
Simpson HETA 20
hurricane anchor at each truss
( 24" o.c.) supporting Max.
1810 lbs. uplift
MODEL:
Date Drawn :
Revisions
5-9-11
GARAGE
Drrawnaven by:
RIGHT
C.C.U.
Checked by:
D.R.B.
H
w
Sheet
I -
OF 5
0
I
M
Ale,.,
Comm #
12-101
PANEL
"A„
circ#
2
Dgscription
AHU
Wire Load BR Poles
410 3.5 kw 30 2
Poles
BR
Load
Wire
Description
circ#
2
40
l.0 kw
#8
A/C comp
1
3
5
4
6
-
Ran a
2
30
4.5 kw
#10
40 gal. water HTR
#L
12.0
kw
50
2
l
8
1
20
1.8 kw
#12
Pump
9
10
Dr er
#10
5.0
kw
30
2
12
1
20
I.5 kw
#12
13
14
Dishwasher
#12
1.2
kw
20
1
1
20
I.5 kw
#12
Microwave
IS
16
Refrigerator
412
1.2
kw
20
1
1
20
1.5 kw
#12
Kitchen S.A.C.
n
is
Recepts
#12
-
20
1
1
20
1.5 kw
#12
Kitchen S.A.C.
19
20
Recepts
#12
20
1
I
120
1.2 kw
#12
Clothes Washer
21
22
Recepts
#12
-
20
1
1
20
0.81 kw
#12
Garage Door Opener
23
24
Recepts
#12
20
1
1
20
1.4 kw
#12
25
24
Recepts
#12
20
1
1
20
1.92 kw
#12
21
28
Recepts
#12
20
1
1
I5
414
General Lighting
29
30
Recepts
#12
20
1
I
Is
#14
General Lighting
31
32
Recepts
#12
20
1
-
1
15
914
General Lighting
33
34
Exterior GFCI
#12
20
1
-
I
I5
#14
General Lighting
35
31.
Bathroom GFI
#12
20
1
1
20
#12
Smoke Detectors
31
38
General Lighting
#14
-
15
1
-
1
20
#12
Bathroom GFI
39
40
General Lighting
1 414
Is
I
1
spare
41
42
s are
PANEL "A" LOAD
CALCULATION SHEET
Load Description
Ot .
Watts
Total(Watts)
General Lighting (3, ,watts sq, ft.)
Small11 , Appliance. C.ircult(s), „ .
Range , _ , , , ,
.Refrigerator.. ............................................
.............................
Microwave Dish Washer..... ...............
.Clothes..Washer..........................................
Clothes..Dryer................................................
Water Heater
Water Pump ...............................................
Garage. Door _Opener, .. _ .
. , ......
. . . .
..
..
1135
3
5,205
2
1,500
3,000
1
12,000
12,000
1
1,200
1,200
I
1,500
1,500
1
1,200
1,200
1
1,200
1,200
1
6,000
5,000
1
4,500
4,500
1
1,800
1,800
1
810
810
Total
Watts
31,415
First 10000 Watts
e100%
1
10,000
10,000
Remainder
21.415 e40%
1
O
10,966
Electric Heat or A/C 10,000 9L5%
1
10,000
10,000
Calculated Load
Watts
30,96L
Voltage
240
Calculated Wattage Divided bg Voltage =
Total Amps
Panel Size Required =
129.03
150 Amps
Electrical S mbol Legend
S
Single Pole Switch
®
Recessed Can Light
S3
Double Pole Switch
®
Egeball Recessed
PB
Push Button Switch
-Cr
Exhaust Fan
Duplex Outlet
¢
Ceiling Mounted Light
_ 0
Special Receptacle
0-
Wall Mounted Light
w. Fi
Waterproof, ground fault interrupter
Light with Pull Chain (attic)
®
Floor Duplex Outlet
©
Computer Connection Jack
en
Carbon Monoxide Detector
Flood Light
TQ
Thermostat
m
Electrical Panel
®
Central Vac
r"I
Electrical Meter
®
Smoke Detector
Ceiling fan
A/C Disconnect
®
Television Jack
Telephone Jack
A ofsc
®
I x 4 Florescent Light
®
2 x 4 Florescent Light
EP
Speaker Hook -Up
❑i
Intercom
®= JUNCTION BOX TO SUPPORT A FAN
O = THERMOSTAT LOCATION
B/A = Balanced Air
Electric Notes:
Vent thru
A/C disc.
PORCH
143 CFM
IOx1Ox1
Center Registers
on Iceiling fan
BEAT
OM
DINING
ROOM
THIRD
BEDROOM
84 CFM
IOxLxL
IS
O
w �
42/0 Aluminum feedhMC 215 CFM
I ' Conduit PANEL 12-If 1
13
x
I. Use copper were onlyy, no aluminum.
2. Provide and wire aTl required smoke detectors.
3. Contractor to verify location of electrical M Te SECOND
service and provider.
4. ALL paddle fans shall be on a rheostat. A BEDROOM
5.
ALL bath and kitchen receptacles to be GFI
rotected.
2 PVC l FFL)-D
6.
ALL exterior outlets to be WP/GFI protected.
7.
Recessed cans to be installed per NFPA requirements.
8.
AFCI receptacles are re uired in all rooms except
9.
Kitchen, Bathrooms, and Garage.
A/C Return Air Balance Must comply w/ FBC RMI602
2' rigid service FPL
oa pS#contpe�a'r' in slab
10.
A/C Refrigerant lines that are run thru slabs must be
sleeved in PVC
ELECTRICAL RISER
11.
ALL A/C Equipment shall comply with energy calculation
12.
All work shall be performed by a licensed electrical
full
- Contractor shall use AL-CLI Landing rugs. NTS
contractor, the completed system shall be operative.
- Contractor shall torque lugs I.A.W.
13.
Contractor shall pay for all fees, permits, tes ing, and
manufacturers recommendations which
inspections Including blower testing where required.
shall be verified prior to construction
14.
All work shall be coordinated with other trades to avoid
interference with the progress of construction.
19. The electrical system shall be completely and effectively
15.
All required insurance shall be provided for protection
grounded as required by the latest edition of the N.E.C.
against the public liability and property damage for the
20. All material shall be new and shall bear underwriters'
duration of the Work.
labels where applicable.
16.
Contractor shall guarantee all materials and workmanship
free of defects for a period of not less than two years from
21. All equipment and panel sizes shall be verified before
the date of acceptance or certificate of occupancy, or one
ordering. The contractor shall provide circuit routings to
year from closing sale of house.
suit the Job conditions.
Correction of defects shall be completed without additional
charge and shall include replacements or repair of any
22. Furnish and install all fixtures as called for on the plans
other phase of installation that may have been damaged.
or as selected by others.
17.
It is not the intent of these plans to show every minor detail
of construction. The contractor shall furnish and install
23. All raceways and pipes placed in or through any concrete
all items for a complete electrical system and provide all
slab shall be spaced a minimum of three diameters of the
the requirements necessary for the equipment to be placed in
largest conduit or pipe from any other service.
proper working order.
18.
All work shall be done in accordance with the N.E.C. and
24. All exposed wire below 9'-1" shall be installed in metal EMT
shall comply with all local codes and ordinances, and shall
conduit.
meet all standard requirements of the local electric utility
25. Dryer Vents to be installed per FBC RM1502
and telephone companu.
1CFM 1
OXIOxI
MASTER
M STER ®\ wP GFC1 BEDROOM
49
B DROOM �I
139 CFM V
IOx10x1 - - / i
163 CFM
IOxlOxl
GREAT '__----- -_
12x B/A I O O
B/A bmoke / Carbon
ra r+l I Monowde Detector
_ cue"
12x I _I FCI
12x10
B/A
e CFM
I
1 8x4x-4 ° 4ia
r =�' L OAS E T I
s I
88x'q4 I I Fci
32 M Vent thru
/ .---r - soffit I r0
DINING � I GFCI
ROOM
° I I / / GFCI I / �GffCIGFCI
° �TCHEN I/ / ° " so FM
1:2
FAN
J \
144 CFM
12xbx1 - - - - - - -2„ 3,_2„ 24,
I \
CFM 1
--° - -- x4x41� THIRD
O ° BEDROOM
N Iw
eW.H
In\J 22" x 84"
N _
IAttie Access
2h GFCI
with light
1 Pd--
Attic Aece
Lu4"� Steel Ballard
I
with light 1
Q II See detail on this sheet
SEE MANUAL \ \ \ \ See ee de+'Otail St el Ballard
/ I
1-- "J" and Energg \ \ _ Q
Calculation - Pull chain /
150 Amp Por Unit info PC
Aght in attic
Panel
S I \ I OPTIONAL PANEL / / 150/ Amp
¢ LOCATION /
Panel
Smoke carbon 42"h GFCIGARAGE
RA E bdaDetector
xomounder GARAGE/
141 rFFA
50 F M OQ I I ' Garage
D n oor
Opener
Exhaust Duct - - _
Thru Soffit
I I I I
I I I I
I I \
h \ I I
tight
I I � to carrier
N SBC'qND l7Y I
BEDROOM \ I 1
I \\
Wire For14
Front Post
Light
WP
IIEC�H/4VCAL L/4YOUT U
Center Post Light on w a
This corner
Q a0
O=THERMOSTAT LOCATION SCALE: 1 / 4 " - I' - O " > m Post Light with
Photo cell
mo
N
(Y
� Exhaust Duct
-_T--hra Soffit
14" Exhaust
Duct Thru
Wall
WP GFCI
Install owlet
ur) under disc.
not shown for
clarity
U
A/C
�7-LEC7RIC/4L PL,4N
SCALE. 1/4" = I'-O"
Total Attic Space = 2481 sq. ft.
Venting Ratio 1/150 = 1(.58 sq, ft. required
Provide A Continuous Vented Soffit
Braden It Braden ,AI,A, FA
UJgnne Building Corp.
MODEL:
Date Drawn
Revisions
Sheet
Architects - Planners
GARAGE
5-9-11
411 S.E. Coconut Avenue
THE R O Y A L E
RIGHT
Drawn by:
� -
Tel : (112) 287-8258
C.C.U.
Spanish Lakes
Fax : (112) 28�"1-8283
E-mail: bradenaia comcast,net
Checked b 9
Stuart. FL 34994 #AAC000032
St. Lucie Count Florida
ID.R-B
OF 5
® LIFE SAFETY WARNING
This s bol identifies Life Safety Warnings that should be read
given ecial attention by all persons installing trusses.
5 GING_NOTE_
ALL T SES ARE TO BE SET
-O: ON CENTER
�:FFT AS NOTED
DONT LIFT TRUSSES
WITH SPANS LONGER THAN
30' BY THE PEAK.
MULTIPLE PLY TRUSSES MUST BE
A ENED TOGETHER PER ENGINEERING
BEFORE SETTING. REFER TO
EN SINEERING DRAWING TO DETERMINE
® IF MULTIPLE PLY.
30' Spanllor less
�60 degrees
or less
2
♦-- —0
Tog Lin-, span approx.
REFER 10 BCSI
Truss 01 ae set this way if crane used.
Trvcs or -,, yaw t,—s may not mamn.
,al t crane hoer etor sets truss tits way_
30' to 60' Span
SDreader Bar
11 ag �_Approx 2/3 to._�
Line 1/2 of Span
REFER TO BCSI
,as must be set this way if crane used.
This is an example, truss may not match.
Insist crane operator sets truss this way.
All load bearing walls, headers,
beams & lintels must be in place
at indicated height before trusses
Q are installed. A
A R HANIll I—IlIlp NOTE
LESS NOTED ELSEWHERE ON THIS LAYOUT, THESE TRUSSES
RE NOT DESIGNED FOR AIR HANDLERS IN THE ROOF OR FOR
ANY OTHER A/C REQUIREMENTS. THIS MAY BE IN CONFLICT
WITH BUILDING CODE AND A/C DESIGN REQUIREMENTS.
ONSULT WITH BUILDING DEPARTMENT AND A/C CONTRACTOR.
Carrying Girder
For Truss to Truss
Connections see
hanger/connectorYNallsmustbeas
de tabs
s hedule in engineeringe nails.
package.
Carried Truss
a®
s�
77
uw
M19
z.•o c. Tenn
WRNLR JACKS f`f16•.
ONLY za•
CORNER -DETAIL
OVERHANGS NOT SHOWN FOR CLARITY
SEAT PLATES BY CHAMBERS
INDICATES LOAD BEARING
REQUIRED BY TRUSSES
LSUPPLIED BY BUILDER
AT A HEIGHT OF 8'-l"
ABOVE FINISHED FLOOR
12
4.00 ___
heel=315116"
PLUMB CUT END
if
it 2 x 4 Top Chord
BEARING HEIGHT Il
TYPICAL END DETAIL
AL
ARRANGE WITH CRANE OPERATOR IN ADVANCE
FOR A SPREADER
BAR OF
18' - 24' IN LENGTH
A
Do not stand on trusses until they are braced per BCSI
& properly nailed to
straps &
hangers
GARAGE LEFT
GARAGE RIGHT
FABRICATION AGREEMENT'
•'�abes cA�o+or laesTAnreo uxra.TwsAolrs�+rpacan® a
' Tiia wpd tleeatplbrt dOr Plopallywhen the truss tva a hotrod w: � �T1atNEo
Tla and �,�
r..= be male h etrkt ac�cldalta twit mw oleo plscaltae ft,am
byvA
byto
d r a War
d» d eaw yo ! no Ina a CArro.e Tnw rmit an Pq
wdt , 1, 1 rtoeoe w btddted Chews Tiye a 6a awwd.6t IM wwt
to beph _q required. arks wA aqe ghectueeee, of In ter"
6 The, ndelelplyd edaoww47ee ntaaq t d'BC81 t oy''WexpeyarwtbyTP18 WWA
'i Oeetery w to Ion .Iw• e w ar bw.r.•rruw,.ww. � �
Albwf"iforWl ==be o Ve�rgr �smsee
le a pUR0liM ORD9t b IbwadT w� d C�hrMeeraTAea•
killarlicaded
• reaaWhe Pike• hake taa be made a; and psld r=1r is a n
P. woke may. a mods d et9wOlbd dale"ltr denary v kw eweet alra
M hreeieable h swtnt d ,�pher b Py Clrethws.Tptee feaoi�b
eat* av ds. l-1R'A permoreh alb .m.d krr etsrw Itd peldw m bmw•
lseoraklib-lywb rsaOfsraetaawOhaaapeatwebr- herein
eldsreiwn df7tsmhem Tim al a tato for Orb Ise l" to undemlprw
ay 9tiarreadea pMlml wharf An d =aadi Ed to hdtihbdtwe owed I
Tnwe Dy.ay %nalwrp amOwW and tlta andra(pnsd'apeae b ' aia
a hrhdnp MWIIays lase, M ddwa h paymwa foe nr1aY a atade�y m
n 0I Parole .. aP fall III epM� lividahed aiweW
•W wih MM td
ft mPMOWN we per"Naonal Standard And RFMcn dMildaiw On
eFar �VMdelplmCanWoo eacteddTniaw
MuMple PIY b uun must be fastened towilher per enpblesring
befom they are set; failure t0 do so can rebultb7 roof compel
Temporary and Permanent bmclnp are requhed and can save Ure
. ' and prop" and b the respomnli lty of Un hul erector:
Study tlw conbsnb of tlw kwu on de0very
• ..7Yraeaomudbeaetadbrowdper * 16plwm ijuf3dnrps.
Tie« Ilnusl be wt plumb and equam
Do not tort bunks or aback or PVwoodt rootlnp mabrld or any
'olhsi cdhftnlrol loads on>,uws" thb earn gjartree, maaiaaw_
• DO Nt')T SET TRUSSES USING THIS LAYOUT
USE LAYOUT DELNHiEDWRH TRUSSES TO SET TRUSSES
CHAMBERS TRUSS INC
3105 Oleander Avenue
Fort'Plen* Florida 34982.6423
800-551-5932
tFortFUM 712"46&M2 Fax 77t4wilnl
.. 772469.2012 ablaut
—�. _ __. -�.._,...._ _... _�.—.�.,.•i;ticfis:Wvr.,,,;"--vir<Mtect'srePresetiFaiive's _. _' ....
Shop ui ..,ng approval Is NOT a
"double check" of the contractor.
The contractor shall remain responsible
for checking field measurements and
other construction criteria. Architect's
approval covers general roof shape,
review of truss strapping, and loading on
structure from Shaul and uplift loatls and
their rasp c ve location,.
Approved 0y: /-�✓"./
Date:_
R raalen & Braden A.I.A. —P.A.
920/93.2 MITE}( 4.2
DESIGN CRITERIA
County SAINT LUCIE
— — Building Department ST LUCIE COUNTY
Wind Design Criteria ASCE 7-2014
Wind Design Method Main Wind Force Resisting
Roofing Material Metal Roof
a� J
Loading in PSF Roof R.D.L.
(S Top Chord Live 20
c Top Chord Dead 7 4.2
Bottom Chord Live 10 Non -Concurrent
o
w Bottom Chord Dead 10 3
° TOTAL Load 37 7.2
v Duration Factor 1.25
cc
c Wind Speed 165mph
cc Top Chord C.B. Sheeting by builder.
0 r Bottom Chord C.B. Sheeting by builder.
Highest Mean Height 12'-0"
L) k4 Building Type ENCLOSED
Building Category II:Non Restrictive
Exposure Category C
Barrier Island No
Conforms to FBC 2014
W
F-
Q
27 TRUSS DRAWINGS ARE ATTACHED TO LAYOUT
Verify DESIGN CRITERIA shown above with the
building department and your engineer.
Design Criteria is the responsibility of the
Chambers Truss Inc. Drawing Name: M11324
Scale: 1 /4 = 1'
83 total trusses, 27 different trusses.
MI 4: SAE ACAD: SAE Reviewed By:1L �i>rs/s —
Date:07/19/12 Revised:10115/15
FOR
WYNNE BUILDING CORP.
DESCRIPTION:
70' CARLTON, ELEV. D
PAGE 1 of 1 CUSTOMER INITIALS EACH PAGE 7V(:M�
M 11324
3 P- ✓e/je / Sfn