FBC ENERGY CONSERVATION CODE R402.4.1.2
House Infiltration Test (Blower Door) Certification
Prescriptive and Performance Method
Da te• 0 ' k G� Permit#: f-707 ®d (5
Contractor:
Job Address: S t 17 YiEFL OU �io1 e C=.�(2 , Tia-T I �4LcF ; FL 754CAA5
Construction: ( Mew Construction—Complete ( ) Existing—After Addition
House InfiltratiQnd t , esuits SLC Climate Zone 2 /
CFM (50)= l l Test Date:
Volume T3 11T50"
qCH (50)=CFM (50)x 60/Volume= Mecha ' a/Ventilation required less than 3 ACH
PIassing results must be&ACH (50)or less ( ass ( ) Fail
FBIC, Energy
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not
exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Texting
shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Testing shall be conducted by either
individuals as defined in Section 553.993(5) or(7), Florida Statutes or individuals licensed as set forth in Section 489.105
(3)(f), (g) or(i)or an approved third party. A written report of the results of the test shall be signed by the party
conducting the test and provided to the code official. Testing shall be performed at any time after creation of all
penetrations of the building thermal envelope.
FBC,Residential
R303.4 Mechanical ventilation. Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when
tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida
Building Code, Energy Conservation the dwelling unit shall be provided with whole-house mechanical ventilation in
accordance with Section M1507.3.
I
Testing Company �J G
Company Name: � � l'L— Address:
I
I,hereby certi the a ove House Infiltration-results demonstrate compliance with FBC Energy Conservation
requireme s in cco with S n R402.4.1.2 Climate Zone 2.
Signature: --
Printed Name:
APR 17 2018
License/Certification#:
Permitting [department
St. Lucie County, FL
I
Planning&Development Services •
Building&Code Regulation Division
2300 Virginia Ave, Rm 201
j Fort Pierce, FL 34982
Q t 772462-2165 Fax 772462-6443
-- -- - — FBC ENERGY CONSERVATION CODE
Duct Sealing Certification
Prescriptive and Performance Method
I
Date: 04 • I G` (e Permit#: �70- 7 — 001 �5 Lot#:
Contractor: Address:
Construction: ost Construction Test ❑Rough-in Test
Test Conditions:
Date: o,4 1 i'o cz Floor Area(ft2): 2r 6 Z3
Time: , Z Primary Location of Supply Ductwork P--MC
Indoor Temperature(F): ti Primary Location of Return DuctworkZ C—
utdoor Temperature(F): -797
Total Leakage Test(Outside)
Duct Leakage: gAefault e0rop.Leak Free ❑Proposed On=
Test Pressure: L-`j (Pa)
Baseline Duct Pressure(optional) (Pa)
Duct Press.(Pa) Flow Ring Fan Press Flow(cfm) Results: Evrass ❑Fail
Installed Pa `)
I -5 3- IT S2.j 2_ - Total Leakage(cfm): _�
p
Total Leakage per 100 sgft:
i
CFM25 x 100 divided by the CFA=Duct Leakage CFM/100 sqft.
Testing Company per, r
Company Name: Address:Qs7o
I hereby certify at t ov D ea ing eakage results demonstrate compliance with 5t'Edition FBC Energy Conservation requirements in accordance with
Section R403.
Signature:
Printed Name: License/Certificate#:
I
i
i
APR 17
2018
PerSmitting DePar
Lucie tment
�OUnty, F.-L