HomeMy WebLinkAboutFlorida Energy Efficiency FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
I
Project Name: WYNNE THE ROYALE Builder Name: WYNNE
Street: WYNNE DEV. Permit Office: ST. LUCIE COUNTY
City,State,Zip: FT.PIERCE, FL, Permit Number:
Owner: � �N 5� Jurisdiction:
Design Location: FL, Fort Pierce County:: ST. LUCIE COUNTY(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1688.7 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 1448.70.ft2
b.Frame-Wood,Adjacent R=11.0 240.d0 ft2
3. Number of units, if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 3 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (1720.0 sqft.) Insulation Area
a. Under Attic(Vented) R=30.0 1720.00 ft2
6. Conditioned floor area above grade(ft2) 1720 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2,
7. Windows(155.4 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 325
a. U-Factor: Sgl, U=0.54 115.42 ft2
SHGC: SHGC=0.25
b. U-Factor: Sgl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency,
SHGC: SHGC=0.25 a.Central Unit 34.8 SEER:15.M
c. U-Factor: N/A ft2
SHGC: 13. Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 34.8 HSPF:8.50
SHGC: •
Area Weighted Average Overhang Depth: 3.316 ft.
Area Weighted Average SHGC: 0.250 14.Hot water systems
8. Floor Types (1720.0 sqft.) Insulation Area a.Electric Cap:40 gal,lons
a.Slab-On-Grade Edge Insulation R=0.0 1720.00 ft2 EF:0 970
b. Conservation features
b. N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.090
Total Proposed Modified Loads: 54.94 PASS
Total Baseline Loads: 56.22
I i
I
I hereby certify that the plans and specifications covered by Review of the plans and 411E STAT
this calculation are in compliance with the Florida Energy specifications covered by this y0 _ g�p
Code. - calculation indicates compliance
with the Florida Energy Code.
PREPAR Dv
Before construction is completed
DATE: this building will be inspected for
compliance with Section 553.908
c
I hereby certify that this building,as designed, is in compliance Florida Statutes.
with the Florida Energy Code. G'Otj WE
OWNER/AGE T: BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1. j
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
COPY
4/3/2017 3:46 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5
j
I ,
FORM R405-2014 j
PROJECT
Title: WYNNE THE ROYALE Bedrooms: 3 Address Type: Street AddresIs
Building Type: User j Conditioned Area: 1720 Lot#
Owner: Total Stories: 1 Block/SubDivision:
#of Units: 1 Worst Case: Yes PlatBook:
Builder Name: WYNNE Rotate Angle: 135 Street: WYNNE DEV.
Permit Office: ST.LUCIE COUNTY Cross Ventilation: No County: ST.LUCIE COUNTY
Jurisdiction: Whole House Fan: No City,State,Zip: FT.PIERCE
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment:
CLIMATE
/ IECC Design Temp Int Design Temp Heating Design Daily Temp
v Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture, Range
FL,Fort Pierce FL_VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low
BLOCKS
Number Name Area Volume
1 Entire House 1720 13760
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 BEDROOM 343 2744 No 0 1 1 Yes Yes I Yes
2 WIC 63 504 No 0 1 No Yes Yes
3 M.BATH 56 448 No 0 1 Yes Yes Yes
4 KITCHEN 172 1376 Yes 0 1 No Yes Yes
5 BATH 45 360 No 0 1 Yes Yes Yes
6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes
7 ENTRY 98 784 No 0 1 Yes Yes Yes
8 LAUNDRY 42 336 No 0 1 Yes Yes j Yes
9 GREAT/DINING 528 4224 No 0 1 Yes Yes Yes
10 BEDROOM 3 169 1352 No 1 1 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio BEDROOM 52 ft 0 343 ftZ ____ 0 1 0
2 Slab-On-Grade Edge Insulatio WIC 1 ft 0 63 ftz ---- 0 1 0
i
3 Slab-On-Grade Edge Insulatio M.BATH 8 ft 0 56 ftz ---- 0 1 0
4 Slab-On-Grade Edge Inslatio KITCHEN 1 ft 0 172 ft2 ---- 0 1 10
5 Slab-On-Grade Edge Insulatio BATH 5 ft 0 45 ftz ---- 0 1 0
i
6 Slab-On-Grade Edge Insulatio BEDROOM 2 42.6 ft 0 204 ftz ---- 0 1 0
7 Slab-On-Grade Edge Insulatio ENTRY 6.3 ft 0 98 ftZ ____ 0 1 0
I
I
4/3/2017 3:46 PM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5
I
FORM R405-2014
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
8 Slab-On-Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 ---- 0 1 0
9 Slab-On-Grade Edge Insulatio GREAT/DINING 48 ft 0 528 ft2 ---- 0 1 0
10SIab-On-Grade Edge Insulatio BEDROOM 3 13 ft 0 169 ft2 ---- 0 1 0
ROOF
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Gable or Shed Metal 1813 ft2 286 ft2 Light 0.6 No 0.9 No j0 18.4
ATTIC
v # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 150 1720 ft2 N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) BEDROOM 30 Blown 343 ft2 0.1 Wood
2 Under Attic(Vented) WIC 30 Blown 63 ft2 0.1 Wood
3 Under Attic(Vented) M. BATH 30 Blown 56 ft2 0.1 Wood
I
4 Under Attic(Vented) KITCHEN 30 Blown 172 ft2 0.1 Wood
5 Under Attic(Vented) BATH 30 Blown 45 ft2 0.1 Wood
6 Under Attic(Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood
7 Under Attic(Vented) ENTRY 30 Blown 98 ft2 0.1 Wood
8 Under Attic(Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood
9 Under Attic(Vented) GREAT/DINING 30 Blown 528 ft2 0.1 Wood
10 Under Attic(Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood
WALLS
Adjacent Space Cavity Width Height Sheathing Framing SoR-- Et In Et In Area R-Vahle-Ernction lar Below
1 N=>SE Exterior Concrete Block-Ext InsfHEDROOM 4.1 9 0 8. 0 72.0 ft2 0 0 0.5 0
2 S=>NW Exterior Concrete Block-Ext InsfaEDROOM 4.1 29 0 8 0 232.0 ft2 0 0 0.5 0
3 W=>NE Exterior Concrete Block-Ext InsiHEDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.5 0
4 S=>NW Exterior Concrete Block-Ext InsuM.BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.5' 0
5 N=>SE Exterior Concrete Block-Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0
6 N=>SE Exterior Concrete Block-Ext InMEDROOM 2 4.1 14 0 8 0 112.0 ft2 0 0 0.5 0
7 NE=>S Exterior Concrete Block-Ext Ind3ffDROOM 2 4.1 2 10 8 0 22.7 ft2 0 0 0.5 0
8 E=>SW Exterior Concrete Block-Ext InQ EDROOM 2 4.1 9 0 8 0 72.0 ft2 0 0 0.5 0
9 SE=>W Exterior Concrete Block-Ext In!EEDROOM 2 4.1 2 10 8 0 22.7 ft2 0 0 0.5 0
10 S=>NW Exterior Concrete Block-Ext InREDROOM 2 4.1 14 0 8 0 112.0 ft2 0 0 0.5 0
11 NE=>S Exterior Concrete Block-Ext Insul ENTRY 4.1 1 5 8 0 11.3 ft2 0 0 0.5 0
12 E=>SW Exterior Concrete Block-Ext Insul ENTRY 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0
I
4/3/2017 3:46 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
I
I
FORM R405-2014
WALLS
Adjacent Cavity Width Height Sheathing Framing Solar Below
SpaceEt In Area R-4/aille Ahqnr
13 S=>NW Exterior Concrete Block-Ext InsillAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 015 0
14 N=>SE Exterior Concrete Block-Ext InsGREAT/DINI 4.1 28 0 8 0 224.0 ft2 0 0 0!5 0
15 W=>NE Exterior Concrete Block-Ext InsGREAT/DINI 4.1 20 0 8 0 160.0 ft2 0 0 015 0
16 N=>SE Exterior Concrete Block-Ext In9EDROOM 3 4.1 13 0 8 0 104.0 ft2 0 0 0i5 0
17 N=>SE Garage Frame-Wood BEDROOM 3 11 30 8 240.0 ft2 0.23 oi5 0 .
DOORS
i
# Ornt Door Type Space Storms U-Value Width Height I Area
Ft In Ft In
1 E=>SW Insulated ENTRY None .39 3 6 8 20 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 W=>NE 3 Metal Low-E Single Yes 0.54 0.25 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds, Exterior 5
2 S=>NW 4 Metal Low-E Single Yes 0.54 0.25 6.9 ft2 1 ft 0 in 1 ft 4 in None None
3 E=>SW 8 Metal Low-E Single Yes 0.54 0.25 23.2 ft2 1 ft 0 in 1 ft 4 in None I None
4 N=>SE 14 Metal Low-E Single Yes 0.54 0.25 36.8 ft2 1 ft 0 in 1 ft 4 in None (None
5 W=>NE 15 Metal Low-E Single Yes 0.55 0.25 40.0 ft2 10 ft 0 in 1 ft 4 in None (None
6 N=>SE 16 Metal Low-E Single Yes 0.54 0.25 16.2 ft2 1 ft 0 in 1 ft 4 in None None
GARAGE
i
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 300 ft2 300 ft2 30 ft 8 ft 11
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356 1605.3 88.13 165.74 .2598 7
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump Split HSPF:8.5 34.8 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block j Ducts
1 Central Unit Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1
I
I
4/3/2017 3:46 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
i
� I
FORM R405-2014
HOT WATER SYSTEM j
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None
j SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume i FEF
None None ft2
DUCTS
—Supply— —Return-- Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 325 ft2 Attic 85 ft2 Default Leakage Attic (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Cooling Jan Feb Mar Apr May X Jun X Jul ri Aug �Xj Sep Oct Nov', Dec
Venting H H Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 781 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
I
I
I
II
I
i
I
i
4/3/2017 3:46 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE ROYALE Builder Name: WYNNE
Street: WYNNE DEV. Permit Office: ST.LUCIE COUNTY
City,State,Zip: FT.PIERCE, FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL, Fort Pierce
i
COMPONENT CRITERIA CHECK
Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air-permeable insulation shall not be used as a sealing material.
Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier. j
Knee walls shall be sealed.
Windows, skylights and doors The space between window/doorjambs and framing and skylights and
framing shall be sealed.
Rim joists Rim joists are insulated and include an air barrier.
Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors) of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I j
vapor retarder with overlapping joints taped.
Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spaces. j
Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated,and sealed to the drywall.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls,or insulation that on installation readily conforms to available
space shall extend behind piping and wiring. j
Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub-floor or drywall.
Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
4/3/2017 3:46 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1