Loading...
HomeMy WebLinkAboutCertification for Design Load Compliance I I Planning&Development Services Department Building&Code Regulations Division R' EVED -- �- 2300 Virginia Avenue,Fort Pierce, FL 34982-(772)46 -1553 JAN 28 2018 Certification for Design Load Compliance ST. Lucie County, Permitting Project Name: Boller Residence ProjectAddresls:r, Yucca Drive, Fort Pierce, FL Permit#: `y —] ^ DW2- Occupancy Type: R-3 Construction Type: V-B INSTRUCTIONS FOR USE: • This certification must be completed,signed,and sealed by the design professional of record. • Submit(2)copies for residential,(3)copies for commercial with all permit applications involving the following: o New Residences(single or multi-family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official.Contact the#above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Residential Code Fifth Edition with 20 15 Supplements using ASCE 7-10 2. Structure Designed as(check one): X Enclosed Partially Enclosed Open 3. Risk Category: _I X II III IV Exposure Category: B X C D 4. Design Wind Velocity 160 mph X ASD LRFD End Zone Width: 5.47 ft S. Mean Roof Height 15 ft Roof Pitch: 6 :12 Parapet: n/a ft 6. Components&Cladding Design Pressures Used:(PSF,based on 10sgft @ 15'MRH,clearly label on all plan openings): Zone 1:20.7-30.6 Zone 2: 19.2-53.3 Zone 3: 33.7-78.8 Zone 4: 33.7-36.3 Zone 5:33.5-44.8 Garage: 27.9-31.4 7. Design Loads: Floor: 55 PSF Roof/Dead: 17 PSF Roof/Live: 20 Balcony: 55 PSF Dock: 40 PSF Deck: 55 PSF Stairs: 40 PSF Fence: NSA PSF Railings: 50 plf PSF 8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that,-to-the best of my knowledge and belief,the attached plans&specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie Count' e, V lA61d�ea ji v/ hat structural elements depicted on these plans provide adequate resistance to the design f ��l��itie'd:..:STNF %;,c Steve Kastner, PE 32927 _ Print Name $ � Cert#&Co.Cert Auth. No. 39 Kastner Engineering, LLC : t_urn a e a Se ® ��y 5320 Florida Palm Ave, Cocoa, FL 32027 Company Name&Address Re,s d,OJI®• 4 e����Q