Certification for Design Load Compliance
ST. Lucie County, Permitting
Project Name: Boller Residence
ProjectAddresls:r, Yucca Drive, Fort Pierce, FL
Permit#: `y
—] ^ DW2- Occupancy Type: R-3 Construction Type: V-B
INSTRUCTIONS FOR USE:
• This certification must be completed,signed,and sealed by the design professional of record.
• Submit(2)copies for residential,(3)copies for commercial with all permit applications involving the following:
o New Residences(single or multi-family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official.Contact the#above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida Residential Code Fifth Edition with 20 15 Supplements using ASCE 7-10
2. Structure Designed as(check one): X Enclosed Partially Enclosed Open
3. Risk Category: _I X II III IV Exposure Category: B X C D
4. Design Wind Velocity 160 mph X ASD LRFD End Zone Width: 5.47 ft
S. Mean Roof Height 15 ft Roof Pitch: 6 :12 Parapet: n/a ft
6. Components&Cladding Design Pressures Used:(PSF,based on 10sgft @ 15'MRH,clearly label on all plan openings):
Zone 1:20.7-30.6 Zone 2: 19.2-53.3 Zone 3: 33.7-78.8 Zone 4: 33.7-36.3 Zone 5:33.5-44.8 Garage: 27.9-31.4
7. Design Loads: Floor: 55 PSF Roof/Dead: 17 PSF Roof/Live: 20 Balcony: 55 PSF
Dock: 40 PSF Deck: 55 PSF Stairs: 40 PSF Fence: NSA PSF Railings: 50 plf PSF
8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that,-to-the best of my knowledge and belief,the attached plans&specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
Count' e, V lA61d�ea ji v/ hat structural elements depicted on these plans provide adequate resistance to the design
f ��l��itie'd:..:STNF
%;,c Steve Kastner, PE 32927
_ Print Name
$ � Cert#&Co.Cert Auth.
No.
39 Kastner Engineering, LLC
:
t_urn a e a Se ® ��y 5320 Florida Palm Ave, Cocoa, FL 32027
Company Name&Address
Re,s d,OJI®• 4 e����Q