HomeMy WebLinkAboutInstallation Packet PERMIT NUMBER PERMIT WORKSHEET ! page 1 of �� New Home (�' Used Nome Installer ( )LO f�!k l (,—I a � License# ��- �(�� � (o �— I Home installed to the Manufacturer's Installation Manual Address of home 1 bL6 AAW L-4 Home is installed in accordance with Rule 15-C being installed u � �1 PX p Single wide [ Wnd Zone 11 Wind Zone III r 11 Manufacturer Q Length xwidth Double wide Installation Decal# NOTE: if home is a single wide fill out one half of the blocking plan Triple/Quad (] Serial# if home is a triple or quad wide sketch in remainder of home I understand Lateral Arm Systems cannot be used on any home(new or used) PIER SPACING TABLE FOR USED HOMES where the sidewall ties exceed 5 ft4 in. Doi Installer's initials �h(J Load Footer , Typical pier spacing bearing size 16' x 16" 18 1/2"x 18 20"x 20" 22"x 22" 24"X 24" 26"x 26" r� t taterai capacity (sq in) (255) 1/2"(342) (400) (484)- (576)- (676) 2 1L 10 s Show locations of Longitudinal and Lateral Systems 1500 ps use dark lines to show these locations s �Of10�t Ud�nB� ( ) ps 3000 ps ps i - interpolated from Rule 15 1 pier spacing table. PIER PAD SIZES I-beam pier pad size 0 9 IQ_ Pad Size q In x Perimeter pier padsize 16 x _787- 18.5 X __---------------- Other pier pad sizes x -------------------------------------: (required by the mfg.) x x Draw the approximate locations of m arria x Li Li Lin wall openings 4 footbrgrester. Use this x symbol to show the piers. x e w801 piers within 2'of end or home per Rule 15C p 24 X 17-1 List all marriage wall openings greater than 4 fool x25 and their pier pad sizes below. ANCHORS Opening Pier pad size � �/`I��/ ///''']]] Oft 5ft I , � 1 , � 1 1 , I 1 , 1 1 1 , 1 I 1 I , , 1 , r-r- ,-f-i_, -,_-,_ ,-T-i-r-r-,--,_ FRAMETIES 1 1 1 I 1 1 1 1 1 1 , , 1 1 1 I 1 1 1 1 L_L_I_J��-1_♦-L_F_I.../-J_+_L_�_L_1_J_.1_1_L_L_1-_1_J_J_♦-L_F_L_1 1 1 1 1 1 I 1 1 1 1 1 I I 1 I 1 1 1 I 1 I 1 1 1 1 1 1 I 1 1 ' within 2'of end of spaced at5'4"OChome 1 1 1 1 1 , 1 1 1 1 1 1 1 1 1 1 1 , 1 1 1 1 1 1 IT 1 1 r-r ^T-7-r-r-r-I-1-1- T'r-rY-�-1-�-T-r-r-r-i 1-1-T-r-r-r�r•41^l-T- -r-1 1 1 1 1 1 1 1 ^r-1 1 r-r-r-1'-,- OTHER TIES TIEDOWN COMPONENTS Number ' 1 Longitudinal StabiliziMDev ce(LSD) Sidewall L_I_J_.,_1_�_L_L_I_J_y_i_L-,._L_I_J-�_�-�_L_N_f_J_J..♦-�,_L_L_I_J_J_J_a_F_1..J_J -'- ._ 1 I I 1 I 1 1 , 1 1 1 1 1 1 1 , 1 1 , 1 1 1 1 1 1 1 1 1 1 1 I 1 1 1 1 ./-�_r1._L_I-..1_.,_*_�_p_I._,_y_y_�_r_�•_r_,_-1-y_+-r_�_F ManUf2CtUfE'f ItPC QWf`1 Longitudinal Longitudinal Stabilizing Device w/Lateral Arms Marriage wall r-r-r--r�-n-+-r-r-'--f--1-y-t^r-r-r-1-�^�-+-r-►'r-r�-n-+-*^r-r-1-'r_�-r-r-r-1 Manufacturer Shearwall PERMIT WORKSHEET I page 2 of 2 PERMIT NUMBER ' Site Preparation POCKET PENEIrROMETER TEST Debris and organic material removed_ D The pocket penetrometer tests are rounded down to 15-00 psf Water drainage:Natural Swale U Pad—VZ Other or check here to declare 1000 lb.soil without testing. X (p00 X 15bD XikQb as ening multi wide units Floor: Type Fastener: Length: Spacing: Walls: Type Fastener: Length: Spacing: POCKET PENETROMETER TESTING METHOD Roof: Type Fastener: Length: Spacing: For used homes a min.30 gauge, 8"wide,galvanized metal strip 1. Test the perimeter of the home at 6 locations. will be centered over the peak of the roof and fastened with gale. roofing nails at 2"on center on both sides of the centerline. 2. Take the reading at the depth of the footer. 3. Using 500 lb_ increments,take the lowest Gasket(weatherproofing roqulr.rrwnt) reading and round down to that increment. I understand a properly installed gasket is a requirement of all new and used homes and that condensation, mold, meldew and buckled marriage walls are a resultofa poorly installed or no gasket being installed. I understand a strip X��C7 X �UC3 X ISDa of tape will not serve as a gasket. nn Installer's initials TORQUE PROBE TEST Type gasket AJ A Installed: The results of the torque probe test is AC!" inch pounds or check Pg. Between Floors Yes here if you are declaring 5' anchors without testing . Atest Between Walls Yes showing 275 inch pounds or less will require 5 footanchors. Bottom ofridgebeam Yes Note: Astate approved lateral arm system is being used and 4 ft. anchors are allowed at the sidewall locations. I understand 5 ft atherprooting anchors are required at all centerline tie points where the torque test reading is 275 or less and where the mobile home manufacturer may The bottomboard will be repaired and/or taped. Yes �. Pg. requires anchors with 00 b holding capacity. Siding on units is installed to manufacturer's specifications. Yes l / Installer's initials Fireplace chimney installed so as not to allow intrusion of rain water. Yes ALL MUST BE PERFORMED BY A LICENSED INSTALLER Miscellaneous Installe Skirting to be installed. Yes_�No `'� Dryer vent installed outside of skirting. Yes 7— N/A Date Tish �. ; Range downflow vent installed outside of skirting. Yes T�N/A Drain lines supported at foot intervals. Yes Electrical crossovers protected. Yes Other: Bectrical Co ne trical conductors between multi-wide units, but notto the main power sou includes the bonding wire between mult-wide units. Pg. Installer verifies all information given with this permit worksheet Plumbing is accurate and true based on the Connect all sewer drains to an e)dsting sewer tap or septic tank. Pg. manufacturer's in lation instrtmtions and or Rule 15C-1 & 2 Installer Si nature Date IMLL15 �5 Connect all potable water supply piping to an e)osting water meter,water tap,or other g Champion Home Builders,Inc. Quote - Revision 3 Hwy 100 East Box 2097 rM No.: SR003513 Lake City,FL 32056 USA Phone:800.223.5471 HOMES OF MERIT- Quote Date: 02/26/15 Phone No.800-223-5471 Retailer P.O.: Fax No.386-752-9560 Order Type: Stock Retail Customer: #83 Bill To: 1737FL Sell To: 1737FL Req.Del.Date: Country Cove MHP, LLC Country Cove MHP, LLC Zone Manager: Blair Kelly Country Cove MHP, LLC Country Cove MHP, LLC Brand: TRINITY 4015 N. US Hwy 1 4015 N. US Hwy 1 N 9� Model No.: TRINITY RH2683A Fort Pierce, FL 34946 Fort Pierce,FL 34946 Base Home: 72 X 16 313D 28A Model Year: 2015 a t� Model Size: 68'0"X 15'2" GG 2 f onstruction Type: HUD Shipping Agent: Serial No.: FL261-OOP-H--B200556A Shipping County: SAINT LUCIE Page:1 of 4 Feature Option Variant Description Quantity Ext.Price Miscellaneous OTHER OP000569 COMMENTS 1 Standard OTHER OP001712 OTHER 225 225.00 EXTEND COUNTERTOP/N MBATH ADD BANK OF DRAWERS Packages OTHER OP002729 MOCHA DECOR PACKAGE 1 Construction WINDZONE OP002784 ZONE 3 PER LF-REDMAN 45 2,070.00 ROOFINS OP002763 R-22 RPL R-14 ROOF INS 1,031 154.65 ROOFPITCH OP000747 ROOF PITCH 3/12 68 Standard FLOORDECK OP000298 5/8"T&G OSB FLOOR DECKING 1,031 Standard FLOORINS OP000495 FLOOR INSULATION R-11 1,088 Standard FLOORJST OP000510 2X6 FLOOR JOIST 19.2"OC 53 Standard WALLINS OP000493 SIDEWALL INSULATION R-11 1,331 Standard SIDEWALHTH OP001665 8'SIDEWALL 68 Standard EXTWALLS OP000281 2X4 EXTERIOR WALLS 16"O.C. 167 Standard INTWALL OP002478 2X3 INTERIOR WALLS 24"OC 97 Standard CLGTYPE OP002192 FLAT CEILING 1,031 Standard SHEATHING OP001278 OSB EXTERIOR SHEATHING 1,452 Standard ROOFSHEATH OP000342 OSB SHEATHING 1,237 Standard OTHER OP000509 KNOCKDOWN CEILING 1 Standard OTHER OP000828 PERIMETER BLOCKING REQUIRED 1 Standard OTHER OPOO1509 CONTINUOUS VENTILATION SYSTEM 1 Standard Exterior HOUSEWRAP OP000350 HOUSE WRAP 1 Standard SHINGLES OP002746 Weathered Wood 3 TAB SHINGLES 1,237 Standard SIDING OP002745 Olive VINYL LAP SIDING 1,452 Standard TRIM OP000381 Black PR 15"VINYL SHUTTERS 1 55.00 TRIM OP002488 WHITE WIDE TRIM AROUND WINDOWS 1 Standard STANDARD/S FRONT DOOR SIDE ONLY.EXTRAS MUST SE CHARGED FOR PER WINDOW. FASCIA OP000562 HARDIE FASCIA 1 Standard Exterior Doors Champion is a registered trademark of Champion Home Builders,Inc f J,(d MODEL_261-RH2683A 3 BEDROOM,-2 BATH �— ACTUAL SIZE: '15'-2"x 68'-0" TOTAL AREA: 1,031 SO. FT. --5�-4" — - ---- 11'-3" —.._ _. _._...._._ 12'_8"_ _ __ --.. _.. 8'-4" �.2� a...2�'8 8'-.5" 3( 308DE 308D i 1 I ;Cbset- ... Master. wnt� — �— _ -Bedroom-2roa_ _�._._ --- Bedroomr Bedroom 3 _ - - - �Fw _ _ <IE Unity - r - - Kitd>ler► Ldli - - oar t urr ---- --- t - — - T oRv wA�►1 ReFr. _.........e.._..... . _. ._._- - - - �;64—� -- - '- - ��. 1. k-.. .._...- - -... 5.5 101_110_ - — - - — 131-1._._- 13 7. ._ _...._.. _..... __.-4.�. DAPIA SFAL MODIFICATIONS MODFL. 261-RH2683A SI IFU 1 iNflod Frord Door 3-to Clonr WaX _� GCK 04.01-14 Redman 2 Added Opt ^— � = 1007.14 71nE: L-�1 01 _�� .. Blaci<Iine-OT027302 U Homes -------._--_._ .__._ PROPRtETARYANOCONFIDENTIAI. DRAWN BY:VMmv DATE.01.03.14 REV. B NtEtk oRANwNOs AI40 SPCCW-K:ATKWS ARE 01410NA4. _ ____ __ _ PROPRIETARY ANO CONFOENTIAl M1,1ERKS OF I'HV.'KV4 Westgate P.0'.d6X 22097 HM 100 EAST LAKE CITY,FL 32056 GOPYRKatll.;loTaronruYrtwrcvr —_ -- Lateral Block Pier System Installation Instructions for Florida Only By Tie Down Engineering Updated: August, 2007 • Easy Installation • Approved for ground or poured concrete sets ups • LSD struts easilyadded for longitudinal protection 9 ' • Frame ties and plates only at system locations Ground 5yotem J (Lateral Only) REQUIREMENTS • Installation can be made in any type of soil, 46 or better • Florida requires 5' 4" anchor spacing for vertical ties • 4' ground anchors are used with the Xi-system in 4A { v and 46 soils, except at shear wall or marriage wall locations where loads exceed 3150 pounds. Florida requires that 5' anchors be used at these locations. • Center line or shear wall anchors, that may be required by specific manufacturers, are to be sized according to Ground 5yotem , soil torque conditions. Follow all manufacturers (Lateral/Longitudinal Combo) instructions for anchor type and placement in addition to Florida regulations. • Poured concrete must be 2,500 PSI minimum at 28 days. • Square concrete pads minimum is 18" wide by 12" deep. Round concrete pads minimum is 18" wide by �"-- •-__ _;y—��J 14" deep. Strip footings minimum is 18" wide by 14' S long by 6" deep. - ` • Maximum height is a 96" projection. Higher walls may Concrete System be used, when the design loads are adjusted accordingly. (Lateral Only) • Maximum roof eave is 16" • Main rail spacing must be 99.5" or less • Maximum pier height of the Xi-system is 48" • Instructions are not for use on "Exposure V homes - within 1500 feet of the coastline • Installation instructions are based on 4200# per pad longitudinal load and 6000# per pad lateral load with one diagonal tie/stabilizer. • Additional vertical anchor ties that are unique to a p C home's design may be required by the homeC> crete System manufacturer. These locations include shear walls, 14 ral/Longitudinal Combo) marriage line ridge beam support posts, and rim plates. AA 0 TIE N DOWN • Drive SW Atlanta, GA 303136O www.tiedown.com1 1 1 Installation of Lateral System 1. Identify the number of systems to be used on the home using the chart provided. 2. Identify the location where the lateral systems will be installed. 3. Clear all organic matter and debris from the pad site. 4. Place pad centered under beam with the lateral strut bracket towards the inside of the home. 5. Press or drive pan into ground until level and flush with prepared surface. 6. Build pier according to State, Local or Home Manufacturers guidelines.(Figure 1) 7. Attach the end of the smaller tube to the inside of pan using U-bolt&nuts provided 8. Attach the flag end of the larger tube to the opposite I-beam using the "J" bolt over the top of the I-beam with the nut &washer provided. (Figure 2) 9. Install a minimum of four(#12 x 1" tek screws) self-tapping screws into the holes provided in the latffal strut so that the two tubes are connected together. (Figure t) Figure 1 Figure 2 1-3/4"Tube Lateral Struts J-Bolt Nut & Washer I �) 19) 1-1/21,Tube 5�(flag end) 4-#12x1" Tek 5crewe �), U-Bolt&mounting .....:... .... Bracket Installation of Longitudinal Struts 1. Identify the number of systems to be used on the home using e the chart provided. 40 Nom 2. Clear all organic matter and debris from the pad site. E n 3. Place u-bolts though holes provided. Attach lock washers on M u-bolt, on the top side of pan —� 4. Press or drive pan into ground until level and flush with prepared surface. h'A 5. Build pier according to State, local or Home Manufacturers guidelines. _ "}. 6. Install frame bracket clamps to I-beam. Do not tighten nuts at this time. Ba 9 7. Insert u-bolt through mount bracket, on longitudinal strut ° attach with nut and bolt. Do not tighten at this time. - - 8. Insert strut in the frame bracket clamp, attach with nut and bolt. Do not tighten at this time. 9. Pull the frame bracket clamps with the fastened strut outward to remove any slack. 10.Tighten all nuts and bolts on the struts and beam clamps. TIE • • Drive WWW.tie0 . . i • 0000 04 040 11 N 0 i Longitudinal and Lateral Stabilization for Florida Xi Lateral LSD Longitudinal LSD Longitudinal Stabilizer Plate& o-- "Only" System "Only" System with Lateral Strut Combo E:> Diagonal Frame Tie (Stabilizer plate used with ground sets only) Homes Up To 52 r Q a I } D Ig a D I a I � I Single Double Section Triple Section or "Tag" Up to 16'Width Up to 32'Width Up to 48'Width 2 Combo Systems 4 Combo Systems 4 Combo Systems 2 Lateral only 2 Additional Longitudinal Xi Piers Homes Over 521, up to 80' $ k I a I 1 I I f I I I I I I I k I I I a I Q I I a Single Double Section Triple Section or "Tag" Up to 16'Width Up to 32'Width ftz Up to 48'Width 2 Combo Systems 4 Combo Systems/2 Lateral Only 6 ems/2 Lateral Only 4 Lateral Onlyf, , Notes: 1. Stabilizer plates only used with Xi "Ground" Sens 2. 5/12 roof pitch home requires 2 additional systems 3. 6 lateral systems up to 52',8 lateral systems up to 80' TIE DOWN ENGINEERING e 255 VillanovaDrive www.tiedown.com. • • I I 0 O Installation of Concrete Bracket: Dry SeVWet Set 1. Identify the number of systems to be used on the home using the is o 0 chart provided. 2. Identify the location where the lateral systems will be installed. L -_ 3. Build pier according to State, Local or Home Manufacturers guidelines. 4a. For dry set: drill two 3/8"x 3" deep holes in the concrete using holes in ` galvanized bracket as a guide. Attach bracket to concrete pad using Ila 3/8"x3-1/2" wedge anchors provided. Place nut & washer on anchor, leave ►&,, enough room for 1 to 2 threads showing on top of bolt. Using a hammer, tap the wedge bolts into hole through bracket, leaving nut & washer flush with bracket. Using a 9/16" socket wrench, tighten wedge/anchor bolt, securing bracket to the concrete. 4b. For wet set: align bracket and submerge legs completelyinconcrete. Bottom of bracket should rest on surface. 5. Attach the end of the smaller tube to the bracket mounted on the pad, using the grade 5 1/2" x 2-1/2" bolt/nut provided. 6. Attach the flag end of the larger tube to the opposite I-beam using the "T bolt over the top of the I-beam with the nut & washer provided. (Figure 1 on page 2) 7. Install a minimum of four(#12 x 1"Tek screws) self-tapping screws into the holes Minimum distance provided In the I ateral strut so that the two tubes are connected together from edge: 1-112" (Figure 2 on page 2). Concrete Lateral/Longitudinal Installations r Lateral —' Stabilization 1-13eam Longitudinal Longitudinal System System S tR , , Lateral stabilization and longitudinal systems on both sides. TIE DO i o . . ! N i v Front:Stylecrest 03/27/2012 13:01 #431 P.023/024 STYLEC7 Ground Installation I REST.1 ' LISP Of Components Fiberglass Step Anchoring (2)484154 Anchor Assemblies Guidelines Each assembly includes: (1) 15 inch Anchor Concrete Installation (1)3/8"x I '/s" lag screw List of Components(Purchased Locally) (1)7116"X 1 '/."washer Ground Installation Guidelines j2e%hU4'x2Dx23WBorn1) Set step in desired position and mark the 2e "�"134 �° anchor placements on the ground. Remove 2eKh U4' 4eah LAVU s step. t,eA Cbnmt 2e�V4'V�s 2) Screw the anchors in the ground so that the �s eye of the anchor will be in the position as shown. Concrete Installation Guidelines 3) Replace step and mark the place where the hole in the eye of the anchor meets the side 1) Drill %4"hole through step and bracket at of the step at the height of the lower frame desired position through lower wooden member. frame member. 4) Fasten screw into tower frame member 2) Install L-brackets using ''/4"x 20 x 2'/a" though eye of the anchor and washer. Bolts,washers,and nuts. 3) Mark location of hole in L-bracket on the concrete. 4) Move the step away from the house. Drill holes in concrete at the desired locations. Tap in '/,"concrete anchors. 5) Replace step so that the tops of the concrete anchors protrude through the L-brackets. Secure with the nuts and washers. WARNING: Failure to anchor the step properly can result in injury.Place th ep against the house.Make sure the surfa hi%the step rests is level. Style Crest,Inc.Drawer A Fremont,Ohio 43 F0G2 �: P- ere 03 , / t 7► O �? ' � 1 C3 ,r i --1- C-- t off, P . P-� � MM ;t t 1 i l 1 � t \ t:1 1 \ i 1 v VERTICAL VINYL SKIRTING ( componentB installation ) WALL 'M P BACK AT.TAGHEO WITH ��f crack S�4BwS (�o �AGART TOP iz'ROtiT v FLOOR SNAPS 1u�o TOP BACA / t De5 SrREWZ ANO PAhAE.t cvTs V f TED PA1s1—� '--�—�^=—�-- BLOCK S u P?O R7' 3.9 'A�KGS PER Foo-r SECuREb '(' C,F �ENTtLATbN O TDPP 5 4c4< Aao 151'JTT0M RAIL vw �.f INGN SC�E4.5 t 4o*, OL dk /g LL CANE LS -4R6 A LCE she BLE �y y REVV%OVLNG `rpP F-ROAJr cwn UP ON FANELI g or�-a ion —r AC k WrTACHCO '["O GROusu6 W eTM 7&rct# 0A WkhriZEo MAIL 19"OC CtF S®eL IS SarjoY'T'4IEN ,cc