HomeMy WebLinkAboutFlorida energy effeciency code FORM R405-2017 FLORIDA ENERGY FULECQU R B UILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: BOLLER RESIDENCE Builder Name: Street: 5108 YUCCA DRIVE Permit Office: City,State,Zip: FT.PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce County: St.Lucie(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2401.8 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 2037.80 ft2 b.Frame-Wood,Adjacent R=11.0 364.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (1885.0 sqft.) Insulation Area a. Roof Deck(Unvented) R=20.0 1885.00 ft2 6. Conditioned floor area above grade(ft2) 1885 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c. R= ft2 11.Duct s R ft2 7. Windows(347.0 sqft.) Description Area a.Sup:Attic, Ret:Attic,AH:Attic 6 150 a. U-Factor: Sgl,U=0.65 235.00 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.67 112.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a.Central Unit 35.4 SEERA6.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Strip Heat 27.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.250 14.Hot water systems 8. Floor Types (1885.0 sqft.) Insulation Area a.Electric Cap:40 gallonsEF:0.980 a.Slab-On-Grade Edge Insulation R=0.0 1885.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits None Glass/Floor Area: 0.184 Total Proposed Modified Loads: 71.13 PASS Total Baseline Loads: 71.52 1 hereby certify that the plans and specifications covered by Review of the plans and O�T$lE ST•grF this calculation are in compliance with the Florida Energy specifications covered by this ti e Off, Code. calculation indicates compliance with the Florida Energy Code. PREPAR D Y: Before construction is completed _ DATE: - this building will be inspected for g compliance with Section 553.908 I herebycertify that this building, as designed, is in c m liance Florida Statutes. fY 9, 9 P with the Florida Energy Cod OD WE OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified fact ory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). 11/18/2018 12:59 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: BOLLER RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1885 Lot# Owner Name: Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 5108 YUCCA DRIVE Permit Office: Cross Ventilation: County: St.Lucie Jurisdiction: Whole House Fan: City,State,Zip: FT.PIERCE, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Block1 1885 20739 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MASTER SUITE 320 3328 No 1 1 1 Yes Yes Yes 2 M WIC 56 526.4 No 0 0 1 Yes Yes Yes 3 M WIC 2 21 197.4 No 0 0 1 Yes Yes Yes 4 M TOILET 24 225.6 No 0 0 1 Yes Yes Yes 5 MASTER BATH 126 1184.4 No 0 0 1 Yes Yes Yes 6 BEDROOM 2 196 1842.4 No 0 1 1 Yes Yes Yes 7 CLST 2 16 150.4 No 0 0 1 Yes Yes Yes 8 BEDROOM 3 196 1842.4 No 0 1 1 Yes Yes Yes 9 GREAT ROOM 349 4711.5 No 0 0 1 Yes Yes Yes 10 HALL BATH 78 733.2 No 0 0 1 Yes Yes Yes 11 KITCHEN 182 2278.6 Yes 0 0 1 Yes Yes Yes 12 DINING 185 2220 No 0 0 1 Yes Yes Yes 13 LAUNDRY 72 676.8 No 0 0 1 Yes Yes Yes 14 FOYER 48 672 No 0 0 1 Yes Yes Yes 15 CLST 3 16 150.4 No 0 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio MASTER SUITE 51.2 ft 0 320 ft2 — 0 0 1 2 Slab-On-Grade Edge Insulatio M WIC 7 ft 0 56 ft2 ____ 0 0 1 3 Slab-On-Grade Edge Insulatio M WIC 2 1 ft 0 21 ft2 0 0 1 11/1812018 12:59 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 2 of 6 I FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 4 Slab-On-Grade Edge Insulatio M TOILET 3 ft 0 24 ft2 ---- 0 0 1 5 Slab-On-Grade Edge Insulatio MASTER BATH 7 ft 0 126 ft2 ---- 0 0 1 6 Slab-On-Grade Edge Insulatio BEDROOM 2 28 ft 0 196 ft2 ---- 0 0 1 7 Slab-On-Grade Edge Insulatio CLST 2 5 ft 0 16 ft2 ---- 0 0 1 8 Slab-On-Grade Edge Insulatio FOYER 8 ft 0 48 ft2 __-- 0 0 1 9 Slab-On-Grade Edge Insulatio CLST 3 5 ft 0 16 ft2 _--- 0 0 1 10SIab-On-Grade Edge Insulatio BEDROOM 3 22 ft 0 196 ft2 ---- 0 0 1 11SIab-On-Grade Edge Insulatio GREAT ROOM 9.9 ft 0 349 ft2 ---- 0 0 1 12SIab-On-Grade Edge Insulatio HALL BATH 1 ft 0 78 ft2 ---- 0 0 1 13SIab-On-Grade Edge Insulatio KITCHEN 1 ft 0 182 ft2 ---- 0 0 1 14Slab-On-Grade Edge Insulatio DINING 38.2 ft 0 185 ft2 _--- 0 0 1 15SIab-On-Grade Edge Insulatio LAUNDRY 8ft 0 72 ft2 ---- 0 0 1 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) I 1 Hip Metal 2108 ft2 0 ft2 Light 0.6 No 0.9 No 20 26.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Unvented 0 1885 ft2 N N CEILING I # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss.Type; 1 Under Attic(Unvented) MASTER SUITE 20 Blown 320 ft2 0.11 Wood 2 Under Attic(Unvented) M WIC 20 Blown 56 ft2 0.11 Wood 3 Under Attic(Unvented) M WIC 2 20 Blown 21 ft2 0.11 Wood 4 Under Attic(Unvented) M TOILET 20 Blown 24 ft2 0.11 Wood 5 Under Attic(Unvented) MASTER BATH 20 Blown 126 ft2 0.11 Wood 6 Under Attic(Unvented) BEDROOM 2 20 Blown 196 ft2 0.11 Wood 7 Under Attic(Unvented) CLST 2 20 Blown 16 ft2 0.11 Wood 8 Under Attic(Unvented) FOYER 20 Blown 48 ft2 0.11 Wood 9 Under Attic(Unvented) CLST 3 20 Blown 16 ft2 0.11 Wood 10 Under Attic(Unvented) BEDROOM 3 20 Blown 196 ft2 0.11 Wood ' 11 Under Attic(Unvented)I GREAT ROOM 20 Blown 349 ft2 0.11 WoodI 12 Under Attic(Unvented) HALL BATH 20 Blown 78 ft2 0.11 Wood 13 Under Attic(Unvented) KITCHEN 20 Blown 182 ft2 0.11 Wood 14 Under Attic(Unvented) DINING 20 Blown 185 ft2 0.11 Wood 15 Under Attic(Unvented) LAUNDRY 20 Blown 72 ft2 0.11 Wood 11/18/2018 12:59 PM EnergyGauge®USA Section R405.4.1 Compliant Software (Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space CavR_Vaity Width Height Sheathing Framing Solar Below 1 N Exterior Concrete Block-Ext InMASTER SUI 4.0999 15 9 4 140.0 ft2 0 0 0.6 0 _2 NE Exterior Concrete Block-Ext InMASTER SUI 4.0999 4 3 9 4 39.7 ft2 0 0 0.6 0 _ 3 E Exterior Concrete Block-Ext InMASTER SUI 4.0999 13 9 4 121.3 ft2 0 0 0.6 0 4 W Exterior Concrete Block-Ext InMASTER SUI 4.0999 19 9 4 177.3 ft2 0 0 0.6 0 5 W Exterior Concrete Block-Ext Insul M WIC 4.0999 7 9 4 65.3 ft2 0 0 0.6 0 6 W Exterior Concrete Block-Ext Instal TOILET 4.0999 3 9 4 28.0 ft2 0 0 0.6 0 7 W Exterior Concrete Block-Ext InsMASTER BA 4.0999 7 9 4 65.3 ft2 0 0 0.6 0 8 S Exterior Concrete Block-Ext InQEDROOM 2 4.0999 16 9 4 149.3 ft2 0 0 0.6 0 9 W Exterior Concrete Block-Ext InEEDROOM 2 4.0999 12 9 4 112.0 ft2 0 0 0.6 0 10 E Exterior Concrete Block-Ext Insul CLST 2 4.0999 3 9 4 28.0 ft2 0 0 0.6 0 11 S Exterior Concrete Block-Ext Insul CLST 2 4.0999 2 9 4 18.7 ft2 0 0 0.6 0 12 S Exterior Concrete Block-Ext Insul FOYER 4.0999 8 11 4 90.7 ft2 0 0 0.6 0 _13 S Exterior Concrete Block-Ext Insul CLST 3 4.0999 2 9 4 18.7 ft2 0 0 0.6 0 14 W Exterior Concrete Block-Ext Insul CLST 3 4.0999 3 9 4 28.0 ft2 0 0 0.6 0 15 E Exterior Concrete Block-Ext InQEDROOM 3 4.0999 6 9 4 56.0 ft2 0 0 0.6 0 _16 S Exterior Concrete Block-Ext InMDROOM 3 4.0999 16 9 4 149.3 ft2 0 0 0.6 0 17 N Exterior Concrete Block-Ext InGREAT ROO 4.0999 10 14 140.0 ft2 0 0 0.6 0 18 N Exterior Concrete Block-Ext Insul DINING 4.0999 13 14 182.0 ft2 0 0 0.6 0 19 E Exterior Concrete Block-Ext Insul DINING 4.0999 10 14 140.0 ft2 0 0 0.6 0 _20 W Exterior Concrete Block-Ext Insul DINING 4.0999 11 14 154.0 ft2 0 0 0.6 0 _21 NW Exterior Concrete Block-Ext InsuKITCHEN 4.0999 4 3 14 0 59.5 ft2 0 0 0 6 0 _22 N Exterior Concrete Block-Ext InsalAUNDRY 4.0999 8 9 4 74.7 ft2 0 0 0 6 0 _23 E Garage Frame-Wood KITCHEN 11 30 9 4 280.0 ft2 0 0.25 0�6 0 _24 S Garage Frame-Wood KITCHEN 11 9 9 4 84.0 ft2 0 0.25 OI6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated MASTER SUI None .4 6 8 48 ft2 WINDOWS Orientation shown is the entered,Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade I Screening 1 N 1 Metal Low-E Single Yes 0.65 0.25 N 30.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds) !None 2 E 3 Metal Low-E Single Yes 0.67 0.25 N 48.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds' I None 3 W 4 Metal Low-E Single Yes 0.65 0.25 N 20.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 4 W 6 Metal Low-E Single Yes 0.65 0.25 N 4.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 5 W 7 Metal Low-E Single Yes 0.65 0.25 N 6.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds, None 6 S 8 Metal Low-E Single Yes 0.65 0.25 N 30.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds !None 7 W 9 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds' I None I 8 S 12 Metal Low-E Single Yes 0.65 0.25 N 6.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds I None 9 E 15 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 10 S 16 Metal Low-E Single Yes 0.65 0.25 N 30.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None i 11/18/2018 12:59 PM EnergyGaugeO USA Section R405.4.1 Compliant Software (Page 4 of 6 I I FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 11 N 17 Metal Low-E Single Yes 0.67 0.25 N 64.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 12 N 18 Metal Low-E Single Yes 0.65 0.25 N 30.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 13 E 19 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 14 W 20 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 15 NW 21 Metal Low-E Single Yes 0.65 0.25 N 10.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 16 N 22 Metal Low-E Single Yes 0.65 0.25 N 9.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 630 ft2 630 ft2 39 ft 9 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000489 2419.6 132.83 249.81 .3901 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 COOLING SYSTEM i # System Type Subtype Efficiency Capacity Air Flow SHR Block! Ducts 1 Central Unit/ None SEER: 16 35.4 kBtu/hr 1062 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 40 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM '1 FSEC Collector Storage 1 Cert # Company Name System Model# Collector Model# Area Volume j FEF None None ft2 DUCTS / —Supply— ----Return-- Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 150 ft2 Attic 15 ft2 Default Leakage Attic (Default) (Default) 1 1 II � 11/18/2018 12:59 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 5 of 6 it FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat:N Ceiling Fans: Coolin Jan [ ]Feb [ ]Mar [ ]Apr Ma rj Jun rl Jul [X]Au rj Se [ ]Oct [ ]Nov [ ]Dec Heating f X�Jan [X]Feb [X]Mar [ ]Apr I May Jun Jul ]Au Sep []Oct [X]Nov [X]Dec Ventin [ Jan [ ]Feb X Mar [X]A r May Jun Jul ]Aug Se [X]Oct [X]Nov [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 MASTER SUITE Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 M WIC Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 M WIC 2 Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 M TOILET Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 MASTER BATH Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 CLST 2 Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 GREAT ROOM Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 HALL BATH i Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 KITCHEN Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 DINING Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 LAUNDRY Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 FOYER Default(8 Ibs/s .ft. 0 ft2 Oft 0.3 CLST 3 i Name: Signature: i I Rating Compant: Date:T I ' 11/18/2018 12:59 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 6 of 6 _ i i 2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 I AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: BOLLER RESIDENCE Builder Name: Street: 5108 YUCCA DRIVE Permit Office: City,State,Zip: FT. PIERCE,FL, Permit Number: Y U Owner: Jurisdiction: w Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/doorjambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wireng. I Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Concealed When required to be sealed,concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a.In addition,inspection of log walls shall be in accordance with the provisions of ICC-400. 11/18/2018 12:58 PM EnergyGaugeO USA FBC 6th Edition(2017)Compliant Software Page 1 of 1 I 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New(From Plans) 12. Ducts, location&insulation level a) Supply ducts R 6.0 2. Single-family or multiple-family 2. Single-family b) Return ducts R 6.01 c)AHU location Attic/Attic 3. No. of units(if multiple-family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 35.4 a) Split system SEER 5. Is this a worst case?(yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area(sq.ft.) 6. 1885 d) Room unit/PTAC EER e) Other 16.0 7.Windows,type and area a) U-factor:(weighted average) 7a. 0.656 b) Solar Heat Gain Coefficient(SHGC) 7b. 0.250 14. Heating system: Capacity 27.0 c)Area 7c. 347.0 a)Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient(SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a)Slab-on-grade(R-value) 9a. 0.0 b)Wood, raised(R-value) 9b. 15.Water heating system c)Concrete, raised (R-value) 9c. a) Electric resistance EF 0.98 b)Gas fired, natural gas EF 10.Wall type and insulation: c)Gas fired, LPG EF A. Exterior: d)Solar system with tank EF 1.Wood frame(Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry(Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B.Adjacent: g) Other 1.Wood frame(insulation R-value) 10B1. 11.0 2. Masonry(Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11.Ceiling type and insulation level a)Ceiling fans a) Under attic 11a. 20.0 b) Cross ventilation No b) Single assembly 11 b. c)Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat No "Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed (or exceeded)in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: 5108 YUCCA DRIVE City/FL Zip: FT. PIERCE, FL 11/18/2018 12:59:19 PM EnergyGauge®USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 I I