Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product Approval ,roof tiles
i I I - ,I BCIS Home I Log In I User Registration I Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff �• BCIS Site Map i Links Search Zlodd,a r Wj Product Approval � USER:Public User Product Approval Menu>Product or Application Search>Application List>Application Detail FL# 3'FL7804-�R9 Application Type Revision Code Version 2014 Application Status Approved Comments Archived 0 Product Manufacturer (Ehtegra.Roof Tle`Inc Address/Phone/Email 1289 NE 9th Avenue Okeechobee, FL 34972 (863)467-0042 Ext1228 tjohnson@rooftile.com Authorized Signature Terry Johnson tjohnson@rooftile.com Technical Representative Jim Deyarmond Address/Phone/Email 1289 NE 9th Avenue Okeechobee,FL 34972 (863)467-0042 JDeyarmond@rooftile.com Quality Assurance Representative Terry Johnson Address/Phone/Email 819 South Federal Hwy Suite 300 Stuart, FL 34994 (800)586-7663 tjohnson@rooftile.com i Category Roofing Subcategory Roofing Tiles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 0 Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity PRI Construction Materials Technologies,LLC Quality Assurance Contract Expiration Date 11/04/2017 Validated By John W.Knezevich,PE Validation Checklist-Hardcopy Received Certificate of Independence FL7804 R9 COI 2016 01 COI Nieminen odf Referenced Standard and Year(of Standard) Standard Year ASTM C1492 2003 FRSA/TRI April 2012 2012 SSTD 11 1997 TAS 100 1995 TAS 101 1995 TAS 102 1995 TAS 102(A) 1995 i • TAS 112 • 1995 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/19/2016 Date Validated 04/20/2016 Date Pending FBC Approval 04/24/2016 Date Approved 06/08/2016 Summary of Products FL# Model,Number or Name Description s7804,1: �Entegra,Concrete Roof Tiles(HVHZ? (Concrete.Robf_:Tlet jurisdictions); Limits of Use Installation Instructions Approved for use in HVHZ:Yes ;FC7804'R9 II 2016 04-fINAL ER EN_TEGRA'FG7804 Approved for use outside HVHZ:No R9 HVHZ:Ddfi Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: N/A Created by Independent Third Party:Yes Other: Refer to ER Section 5 for Limits of Use.Refer to ER Evaluation Reports Section 6 for Installation. FL7804 R9 AE 2016 04 FINAL ER ENTEGRA FL7804- R9 HVHZ.odf Created by Independent Third Party:Yes 7804.2 Entegra Concrete Roof Tiles(non- Concrete Roof Tile HVHZ jurisdictions) Limits of Use Installation Instructions Approved for use In HVHZ: No FL7804 R9 II 2016 04 FINAL ER ENTEGRA FL7804- Approved for use outside HVHZ:Yes R9 NON-HVHZ.Ddf Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: N/A Created by Independent Third Party:Yes Other: Refer to ER Section 5 for Limits of Use. Refer to ER Evaluation Reports Section 6 for Installation. FL7804 R9 AE 2016 04 FINAL ER ENTEGRA FL7804- j R9 NON-HVHZ.Ddf Created by Independent Third Party:Yes I I Back F..1 i Contact us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 i The State of Florida is an AA(EEO employer.Coovrinht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement I Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a'personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S., please click here. Product Approval Accepts: IWO eCheck Credit Card Safe f I I • i EXTERIOR RESEARCH&DESIGN,LLC. i ® Certificate of Authorization#9503 TRINITY IERQOD 353 CHRISTIAN STREET,UNIT#13 OXFORD,CT 06478 PHONE: (203)262-9245 FAX:(203)262-9243 EVALUATION REPORT 1" Entegra Roof Tile,LLC Evaluation Report E39310.11.11-1-R3 NTEGRA 1289 NE 9th Avenue FL7804-119 R O O F T I L E Okeechobee,FL 34972 Date of Issuance:11/02/2011 Revision 3:04/18/2016 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code (HVHZ)sections noted herein. DESCRIPTION: Entegra Concrete Roof Tiles(HVHZ jurisdictions) LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted . herein. CONTINUED COMPLIANCE: .This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words 'Trinityl ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 9. Prepared by: Lu Robert J.M.Nieminen,P.E. The facsimile seal appearing was authorized by Robert Nieminen, -1 µi,,,•.-.—.` P.E.on 04/18/2016.This does not serve as an electronically signed Florida Registration No.59166,Florida DCA ANE1983 4'tj$�! t. ;9 Q1t a s•`.. document signed,sealed hardcopfes have been transmitted to the kw/Jh,.asNlts� Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the'! product. 5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for;any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained, specifically for that purpose. File Cop Q0TRR1NrrYJERD ROOFING SYSTEM EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Roofing Tiles Compliance Statement: Entegra Concrete Roof Tiles, as produced by Entegra Roof Tile, LLC, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1523.6.5.2 Physical Properties TAS 112 1995 1523.6.5.2 Wind Driven Rain TAS 100 1995 1523.6.5.2.2 Static Uplift Resistance TAS 101 1995 1523.6.5.2.3 Static Uplift Resistance TAS 102 1995 1523.6.5.2.3 Static Uplift Resistance TAS 102(A) 1995 3. REFERENCES: Enti Examination Reference Date ERD(TST6049) TAS 101 P39740.02.12 02/21/2012 ATL(TST3782) Physical Properties RT0624.05-14 07/03/2014 ATL(TST3782) Physical Properties RT0624.04-14 07/07/2014 ATL(TST3782) Physical Properties RT1210.02-15 12/17/2015 ATL(TST3782) Physical Properties RT1210.03-15 12/17/2015 ATL(TST 3782) Physical Properties RT1103.01-15 11/07/2015 ATL(TST 3782) Physical Properties RT1103.02-15 11/07/2015 ATL(TST 3782) Physical Properties RT1103.03-15 11/07/2015 ATL(TST 3782) Physical Properties RT1103.04-15 11/07/2015 ATL(TST 3782) Physical Properties RT1103.05-15 11/07/2015 Miami-Dade(CER1592) HVHZ Compliance 14-0416.12 11/27/2014 Miami-Dade(CER1592) HVHZ Compliance 15-0721.04 11/05/2015 Miami-Dade(CER1592) HVHZ Compliance 16-0112.06 02/25/2016 Miami-Dade(CER1592) HVHZ Compliance 16-0112.07 02/25/2016 Miami-Dade(CER1592) HVHZ Compliance 16-0112.08 02/25/2016 Tile Roof Institute TAS 100,TAS 101,102,102(A) Membership Confirmation Current PRI(QUA9110) Quality Assurance Inspection Report 11/04/2015 I Exterior Research and Design,U.C. Evaluation Report E39310.11.11-i-R3 Certi/Icate of Authorization#9503 FL7804-R9 Revision 3:04/18/2016 Page 2 of 9 i i I QOTRR1N1TYjEkP , 4.2 BELLA HIGH"S"are TAS 112,Type 1a(interlocking,high-profile)concrete roof tiles. 13.4'. Bella High"S" 4.3 ESTATE"S"and HACIENDA are TAS 112,Type 1b(interlocking,low-profile)concrete roof tiles. Nail Holes • • 611 �3 Estate"S" I e '5 I Hacienda i I Exterior Research and Design,LLC. Evaluation Report E39310.11.11-1-R3. Certificate of Authorization#9563 FL7804-R9 Revision 3:04/18/2016 Page 4 of 9 I I I . I TRINITY ERD 4.4 GALENA SPANISH"S"and REGAL are TAS 112,Type 2a(non-interlocking,high-profile)concrete roof tiles. 17" 10" Galena Spanish"S" e a 13 114" i Regal 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the' Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is for use in FBC HVHZ jurisdictions or other jurisdictions adopting FBC HVHZ requirements. I 5.3 Fire classification is not part of this evaluation; refer to FBC Section 1516 or current Approved Roofing Materials Directory for fire rating of this product. 5.4 Reference is made to FBC Section 1512.4.2.4 regarding field testing of completed tile roof installations. 5.5 Applicant shall retain the services of an FBC listed, accredited laboratory to perform quarterly tests in accordance with TAS 112,Appendix'A. Such testing shall be submitted to Trinity I ERD for review. 5.6 Minimum underlayment shall comply with the RAS 118, RAS 119 or RAS 120, as applicable. Underlayment products shall hold Florida Statewide Product Approval or Local Approval for use in tile roof assemblies in HVHZ jurisdictions. 5.7 Minimum roof deck requirements shall be in accordance with applicable FBC HVHZ requirements. 5.8 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C.Rule 61G20-3. Exterior Research and Design,I.I.C. Evaluation Report E39310.11.11-1-R3 Certificate afAuthorization#9503 FL7804-R9 Revision 3:04/19/2016 Page 5 of 9 I 11 I � QOTRINITYIERD , 6. INSTALLATION: 6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar-set or adhesive-set. Installation shall comply with manufacturer's current published instructions, but not less than the requirements of RAS 118, RAS 119 or RAS 120,as applicable. 6.2 Attachment Calculations: Entegra Concrete Roof Tile shall be evaluated as a `Moment-Based System' in accordance with RAS 127-11 using the data outlined herein. Lt TABLEI AERODYNAN1tC.MULTIPLIER -ar(FT3) ".: Tile Batten Application Direct-Deck Application Bermuda Flat 0189 0.205 Plantation Flat 0.267 0.289 Horizon Flat 0.305 0.330 Bella High"S" 0.349 0.378 Estate"S" 0.267 0.289 �- Hacienda 0.267 0.289 I Galena Spanish"S" N/A 0.235 Regal 0.287 0.311 TABLE 2, RESTORING MOMENT DUE TO GRAVITEFT-LBF) =. � I Roof Slope(0) I Tile 2.12<0<3:12 3:12c0<4:12 4:1240<5:12 5,12<0<6.12 6:12<0<7:12 0>7:12I Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct ` Bermuda Flat 5.22 6.43 5.17 6.37 5.09 6.27 4.98 6.15 4.86 6.00 4.72 91.83 11 Plantation Flat 7.22 7.91 6.85 7.79 6.75 7.67 6.61 7.52 6.44 7.32 6.26 7;.04 Horizon 7.60 8.32 7.52 8.24 7.41 8.12 7.26 7.95 7.09 7.76 6.89 7i 55 Bella High"S" 6.19 6.89 6.11 6.80 5.99 6.67 5.85 6.51 5.68 6.33 5.50 6.13 Estate"S" 6.14 6.84 5.91 6.74 5.82 6.64 5.70 6.50 5.56 6.33 5.40 6.14 Hacienda 5.92 6.80 5.92 6.80 5.82 6.69 5.70 6.55 5.56 6.39 5.41 6 22 Galena Spanish"S" N/A 6.20 N/A 6.13 N/A 6.03 N/A 5.89 N/A 5.74 N/A 5157 Regal 7.77 8.34 7.77 8.34 7.65 8.20 7.49 8.03 7.30 7.83 7.10 7�61 I I Exterior Research and Design,LLC. Evaluation Report E39310.11.11-1-R3 Certificate of Authorization#9503 FL7804-R9 Revision 3:04/18/2016 Page 6 of 9 I I I TRINITY I ER® ;TABLE'3A-1c ATTACHMENT RESISTANCE EXPRESSED AS A.MONIENT-MF(FT-LBF) _ FLAT PROFILE TILES,MECHANICALLYATTACHED SYSTEMS Fastener Direct-Deck Direct-Deck (min.15/32" (min.29/32" Tile Type # Size Shank Clip plywood) plywood) Battens Nail One(1) 10d Smooth or Screw N/A 7.3 9.8 4.9 Nail Two(2) 10d Smooth or Screw N/A 14.0 18.8 7.4 Nail One(1) 10d Smooth or Screw Eave 19.0 19.0 22.1 Nail One(1) 10d Smooth or Screw Field 24.3 24.3 24.2 Bermuda Flat, Nail Two(2) 10d Smooth or Screw Eave 31.9 31.9 32.2 Plantation Flat or Nail Two(2) 10d Smooth or Screw Field 35.5 35.5 34.8 Horizon Nail Two(2) lod Ring N/A 30.9 38.1 17.2 Nail' Two(2)' 10d' Ring' N/A 50.31 65.5' 48.3' Screw One(1) #8 N/A N/A 30.8 30.8 18.2 Screw Two(2) #8 N/A N/A 51.7 51.7 24.4 1Installation with a 4-inch tile headlap and fasteners located min.2'/=-inch from head of tile. TABLE 3A-2: ATTACHMENT RESISTANCE-EXPRESSED AS A MOMENT-MF(FT-LBF) FLAT PROFILE,TILES,ADHESIVE-SET SYSTEMS Size(inch) Weight(g) To To Tile Application Adhesive Substrate To Tile Substrate To Tile Mf(ft-lbf) TILE BOND'°' 1 x 6 1 x 6 `11 -11 40.6 Touch'n Seal-StormBond 1.25 x 10 1.25 x 8 -8.3 -10.2 712 Inter- Bermuda Flat, Dependent ICP Adhesives Polyset RTA-1; -5"long -'4.5" 9 -5 51.8 Plantation Flat or cross-bond oblong across head Horizon ICP Adhesives Polyset AH-160 4 x 4 2 x 4 -16 -8 42.8 j Independent ICP Adhesives PolysetAH-160 2 x 7 N/A -30 N/A 50.9 2 x 10 N/A 1 -45 N/A 91!9 j TABLE 3B-1: ATTACHMENT RESISTANCE EXPRESSED AS A MOMENT-MF(FT-LBF) LOW PROFILE,TILES,MECHAMfALLYATFACHEDSYSTEMS . Fastener Direct-Deck Direct-Deck Tile Type # Size Shank Clip (min.25/32" (min.19/3z" p ywood) plywood) Battens Nail One(1)' 10d Smooth or Screw N/A 8.82 11.8' 4.1? I Nail Two(2) 10d Smooth or Screw N/A 16.4 21.9 7.11 Nail One(1)2 10d Smooth or Screw Eave 19.D2 19.0, 22.11' Nail One(1)Z 10d I Smooth or Screw Field 24.3' 24.32 24.22 j Nail Two(2) 10d Smooth or Screw Eave 31.9 31.9 32.2 Estate"S"or Hacienda Nail Two(2) 10d Smooth or Screw Field 35.5 35.5 34.13 Nail Two(2) 10d Ring N/A 27.8 37.4 28.8 Nail1 Two(2)1 10d' Ring' N/A 43.01 67.51 50.91 Screw OneM' #8 N/A N/A 25.82 25.82 22.9' N/A N/A 47.1 47.1 49.1 1Installation with a 4-inch tile headlap and fasteners located min.2Y.-inch from head of tile. Z For one(1)fastener installations,utilize hole that is approximately 414-inch from the interlocking edge. I j I Exterior Research and Design,LLC. Evaluation Report E39310.11.11-1-R3 Certificate of Authorization#9503 FL7804-119 Revision 3:04/18/2016 Page 7 of 9 ' i I I TRINITY I EKD 7. LABELING: 7.1 Each unit shall bear the imprint and/or identifiable marking of the manufacturer's name or logo,as detailed below. Tile lots shall be labeled in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. and/or �� ENTE [RRR Labeling:Bermuda Flat,Plantation Flat,Estate"S",Bella High"S",Galena Spanish"S" I and/or I. H n on I Labeling:Horizon Flat,Hacienda,Regal 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Plant Profiles Okeechobee,FL Bermuda Flat,Plantation Flat,Estate"S",Bella High"S",Galena Spanish"S" j Ft. Myers,FL Horizon Flat,Hacienda Deerfield Beach,FL Horizon Flat,Hacienda,Regal 10. QUALITY ASSURANCE ENTITY: PRI Construction Materials Technologies,LLC.—QUA9110;(813)621-5777 -END OF EVALUATION REPORT— Exterior Research and Design,I.I.C. Evaluation Report E39310.11.11-1-R3 Certificate of Authorization#9503 FL7804-R9 Revision 3:04/18/2016 Page 9 of 9 i r— I ' ,. s�;x, •� � s� yu,1'•" ; �.c � Syr ,y y <.. v..�'>: a'' . '2. ,� I METAL STRUCTURE HIP AND RIDGE SUPPORT Mechanical Option (Cont.) FHW-14A HIP AND RIDGE ATTACHED WITH CODE—,APPROVED ADHESIVE INSTALL PER MANUFACTURERS PRODUCT APPROVAL I CODE APPROVED ADHESIVE z: UNDERLAYMENT APPROVED FOR ADHESIVE APPLICATIONS METAL HIP AND RDGE--FRAME INSTALL PER MANUFACTURERS m PRODUCT APPROVAL W i i o i 16 ���� \ :��•y rrv�� i SEAL NAIL PENETRATION WITH COMPATIBLE ROOF CEMENT UNLESS UNDERLAYMENT MEETS ASTM NOTE: Stacking of nailer boards D--19 D SECTION 7.9- may be.used. Maximum thickness of per additional nailer board. The drawings are Fur illustrative purposes only. i COPYRIGHT© FRSA/TILE ROOFING INSTITUTEFHe April 2012 Cu y