HomeMy WebLinkAboutProduct Approval EXTERIOR RESEARCH&DESIGN,I.I.C.
Certificate of Authorization#9503
353 CHRISTIAN STREET,UNIT#13
` �� OXFORD,CT 06478
- PHONE:(203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
East Coast Metals,Inc. Evaluation Report E10240.08.08-R4
2301 West 8 Lane " FL5374-R4
Hialeah,FL 33010 Date of Issuance:09/03/2008
Revision 4:03/17/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 5th Edition(2014)Florida Building Code sections noted herein.
DESCRIPTION: East Coast Metals Channel Metals
LABELING: Labeling shall be in accordance with the requirements.the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E.if the product changes or the
referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in
` advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by: "
Robert J.M.Nieminen,P.E, ; :' The facsimile sea]appearing was authorized by Robert Nleminen,
P.E.on 03/17/2015.This does not serve as an electronically signed
Florida Registration No.59156,Florida DCA ANE1983 d=ment,signed,sealed hardcoples have been transmitted to the
JJ/pb<I t)O}t
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity)ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither Trinity)ERD nor Robert Nieminen, P.E. are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
I I -
TRINITY ERD
`$ ROOFING COMPONENT EVALUATION:
1. SCOPE:
f
Product Category: Roofing
Sub-Category: Roofing Accessories that are an Integral Part of the Roofing Systenj
f Compliance Statement: East;:oast Metals Channel Metals, as produced by East Coast Metals, h�ve demonstrated compliance
with the following sections ofl he Florida Building Code through testing in accordance with the following Standards. Compliance
is subject to the Installation RE juirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.3.7 Installation,non-HVHZ FRSA/TRI April 2012(04-12) I 2012
1518.8.1 Installation,HVHZ RAS 118,119&120 1995
1523.6.5.2.2 Static Uplift Resistance TAS 101 1995
1711.2.1 I Static Uplift Resistance SBCCI SSTD 11 1997
I
3. REFERENCES:
Entity Examination Reference Date
ERD(TST6049) Static Uplift Resistance E42730;08.13 08/23/2013
ERD(TST6049) Static Uplift Resistance ECM-SC6795.12.14-1 02/27/2015
ERD(TST6049) Static Uplift Resistance ECM-SC6795.12.14-2 02/27/2015
Florida TEC(TST7393) TAS 101 S10-628R I 10/27/2010
PRI(TST5878) TAS 101 ECM-001-02-01 09/21/2001
PRI(TST5878) TAS 101 ECM-003-02-01 l 06/13/2008
PRI(TST5878) TAS 101 ECM-004-02-01 06/13/2008
PRI(TST5878) TAS 101 ECM-005-02-01 06/13/2008
PRI(T5T5878) TA5101 ECM-006-02-01 06/13/2008
PRI(TST5878) TAS 101 ECM-007-02-01 06/13/2008
PRI(TST5878) TAS 101 ECM-008-02-01 06/13/2008
Florida Building Code I Attachment Requirements FRSA/TRI April 2012(04-12) 04/2012
Florida Building Code-HVHZ Attachment Requirements RAS 118,119 and 120 1995
East Coast Metals Metal Quality Mill Certifications Various
r Architectura6TestinD(GLUA184 ) Quality Control Participation Letter Exp.12/31/2018
PRODUCT DESCRIPTION:
4.1 Hip & Ridge Channe Metal: Pere-formed metal channel
designed for use as a ip and ridge base to which roof tiles
are bonded in_EBC,Apl"`;roved roof tile adhesive.
---------------
Hip&Ridge Channel Aetal is available in 119-3/8-inch (±
3/8-inch)length by 2.! ,3,3.5,4,5,6 or 7-inch(±3/8-inch).
heights with 1.5-inch; :1/16-inch)deck-flanges.
I
i
i
i
i .
i
Exterior Research and Design,LLC. Evaluation Report E10240.08.08-R4
Certificate of Authoriratlon#9503 FLS374-114
Revision 4:03/17/2015
Page 2of7
i
EPO
4.2 Trim Lock Channel Metal: Pre-formed metal channel ,f.
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof tile adhesive. Trim Lock
Channel Metal is characterized by its profiled and
perforated upper horizontal flange designed to receive
and allow for interlock with the overlying tile adhesive.
Trim Lock Channel Metal is available in 119-3/8-inch (± _
3/8") length by 3, 3.5, 4, 5 or 6-inch l±3/8-inch) heights '.
with 1.5-inch(±1/16-inch)deck-flanges.
,A
Y•� 4
- -5
4.2 Trim Lock Plus Channel Metal:Pre-formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof tile adhesive. Trim Lock
Plus Channel Metal is characterized by its profiled and
perforated upper horizontal flange designed to receive
and allow for interlock with the overlying tile adhesive
and its perforated deck flanges, designed for installation
atop the roof underlayment via placement in FBC D`
Approved roof the adhesive, which flows-through and a.;.
interlocks with the underlying adhesive.
Trim Lock Plus Channel Metal is available in 119-3/8-inch -
(±3/8")length by 3,3.5,4,5 or 6-inch(±3/8-inch)heights
with 1.5-inch L 1/16-inch)deck-flanges.
4.4 East Coast Metals Channel Metals are fabricated of the following metals:
➢ Galvanized Steel: Min.0.019±0.002-inch,ASTM A653(G-90),min.33 KSI.
➢ Galvalume Steel: Min.0.019±0.002-inch,ASTM A792,AZ55,min.35 KSI.
➢ Aluminum: Min.0.032+0.002-inch,ASTM B209,3003-1-114,min.21 KSI.
➢ Stainless Steel: Min.0.019±0.002-inch,ASTM A240/A480,T304,min.35 KSI.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityIERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on %Vhich this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
Exterior Research and Design,I.I.C. Evaluation Report E10240.08.08-R4
Certificate of Authorization#9503 FL5374-R4
Revision 4:03/17/201S
Page 3 of 7
\J TRINITY I ER® '
5.2 FOR HVHZ JURISDIC'IONS:
' 5,21 For Hip & Ridge Ch innel Metal or Trim Lock Channel Metal, refer to FBC RAS 118, Drawing 13, Detail 3; RAS 119,
Drawing 12, Detail ; or RAS 120, Drawing 15, Detail 3. For Trim Lock Plus Channel Metal, refer to the installation
instructions herein.
5,2.2 For HVHZ jurisdictio. s,installations of Hip&Ridge Channel Metal and Trim Lock are prescriptive by RAS 118, 119 and
120,and the data in 'ables 1A and 113 is supplemental to these prescriptive allowances.
Installations of Trim,.ocic Plus are limited to projects having a required moment resistance(Mr)or uplift resistance(F,),
as determined in ace)rdance with RAS 127,not greater than the following values.
Refer to the tile adhi live manufacturer's published installation instructions for adhesive paddy placement details.
➢ "INDEPENDEN " paddy placement means each individual tile is bonded to the Channel Metal in its own, single
foam paddy; + le head laps are not bonded. This method is limited to 2-part tile adhesives. Allowable
performance d ita below for"INDEPENDENT" paddy placement already has a 2 to 1 margin of safety applied to
ultimate perfoi nance.
➢ "INTERDEPEND:NT"paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy,
i and a second f lam paddy bonds the tile head lap,or two tiles are bonded to the Channel Metal using a single
foam paddy. A lowable performance data below for"INTERDEPENDENT"paddy placement already has a 4 to 1
margin of safet applied to ultimate performance.
r .f �y �TABL LA RkRFORMANCETiMIrATIONS o— INDEPENDEN(P2ODY;PLA(iE{Uj6NT*
Xi.twr_V
Hip/Ridge Metal Adhesive Allowable Performance
Tile Moment Based Uplift Based
Design Metal Type Type Placement Mf(ft-Ibf) F(Ibf) :
Hip&Ridge clay or 3ML 2-Component Foam
Channel Metal galvanized _ concrete Roof Tile AdhesiveAH-160 Independent 127 169
Trim Lock galvanized,Galvalume® clay or 31VIT"2-Component Foam Independent 171 159
aluminum or stainless s:el concrete Roof Tile Adhesive AH-160
Trim Lock Plus galvanized,Galvalume®. clay or 131VIII 2-Component Foam Independent 177 165
aluminum or stainless si!el concrete Roof Tile Adhesive AH-160
PERfORMANC-E I.Irk(l(TA�'fONSYtWUHT.,t`fNTERDEPEND�N7'nPADDY R1�10ElV�ENTe - F ,. i xv L
'' .�tr �.ir -tJ Fri . N S� � �,... Ft,. t�.§ � :<. fi -. � i; ✓� _F y e. {'
•f,f_,_
Hip/Ridge Metal Adhesive Allowable Performance
Design Metal Type Tile Type Placement Moment Based Uplift Based
_ Mt(ft-Ibf) F'(Ibf)
Trim Lock or Trim galvanized,Galvalume®, clay or 3M'"'2-Component Foam Interdependent 95 88
Lock Plus aluminum or stainless st el concrete Roof Tile Adhesive AH-160
galvanized,Galvalume", clay or 3M'm Roof Tile Adhesive
Trim Lock stainless steel concrete RTA-1 Interdependent 99 94
Trim Lock aluminum clay or 3M'""Foam Roof Tile Interdependent 90 84
concrete Adhesive RTA-1
Trim Lock Pius galvanized,Galvalume", clay or 31V11"'Foam Roof Tile Interdependent 90 84
aluminum or stainless st( sl concrete Adhesive RTA-1
Trim Lock galvanized,Galvalume®c clay or TILE BOND""Roof Tile Interdependent 123 117
stainless steel concrete Adhesive
Trim Lock aluminum clay or TILE BOND'"Roof Tile Interdependent 79 73
concrete Adhesive
Trim Lock Plus galvanized,Galvalume®, clay or TILE BOND'""Roof Tile Interdependent 79 73
aluminum or stainless ste !I concrete Adhesive
Trim Lock galvanized,Galvalume®o clay or Touch'n Seal StormBond Interdependent 146 139
stainless steel concrete Roof Tile Adhesive
Trim Lock Aluminum clay or Touch'n Seal StormBond Interdependent 58 54
concrete Roof Tile Adhesive
Trim Lock Plus galvanized,Galvalume", clay or Touch'n Seal StormBond Interdependent 58 54
aluminum or stainless ste I concrete Roof Tile Adhesive
Exterior Research and Design,I.I.C. Evaluation Report E10240.08.08-R4
Certificate of Authorization#9503 FL5374-R4
Revision 4:03/17/2015
Page 4 of 7
I_ __I
i
i
Tf ;INITY ERD
5.3 FOR NON-HVHZ JURISDICTIONS:
5.3.1 For Hip&Ridge Channel Metal or Trim Lock Channel Metal, refer to FRSA/TRI April 2012(04-12). For Trim Lock Plus
Channel Metal,refer to the installation instructions herein
5.3.2 For non-HVHZ,installations are limited to projects having hip and ridge design pressure requirements,determined in
accordance with Table 1A of FRSA/TRI April 2012 (04-12), not greater than the following values. Refer to the tile
adhesive manufacturer's published installation instructions for adhesive paddy placement details.
➢ "INDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in its own, single
foam paddy;tile head laps are not bonded. This method is limited to 2-part tile adhesives. This method is limited
to 2-part tile adhesives. Allowable performance data below for"INDEPENDENT"paddy placement already has a 2
to 1 margin of safety applied to ultimate performance.
➢ "INTERDEPENDENT"paddy placement means each individual the is bonded to the Channel Metal in a foam paddy,
and a second foam paddy bonds the tile head lap, or two tiles are bonded to the Channel Metal using a single
foam paddy. Allowable performance data below for"INTERDEPENDENT"paddy placement already has a 4 to 1
margin of safety applied to ultimate performance.
� " a; �, : �r,�„�� � �e r-� � r ��wr�-. •ate � � '-��r-as ��" ^..� :. � � r ,
;k�?_= x� �'� � � TABLE 2�A PERfx ORI111A'NC,E I:IMRATIONS��TIOId�FIY,HZr INDEPENDENTsPADDY PLACEMENT � �+,.,, � y-� �. _
Hip/Ridge Metal Adhesive Allowable Uplift
Tile
Design Metal Type Type Placement (psf)
rliip&Ridge clay or 3MTM 2-Component Foam Roof
galvanized Independent 169
Channel Metal concrete Tile Adhesive AH-160 P
Trim Lock galvanized,Galvalume®,aluminum or clay or 3MTM 2-Component Foam Roof Independent 173
stainless steel concrete Tile Adhesive AH-160
Trim Lock Plus galvanized,Galvalume",aluminum or clay or 31VITM 2-Component Foam Roof Independent 178
stainless steel concrete Tile Adhesive AH-160
�ETABLEZBPER 0 MANCT ITA oNS '' oN H1lHZ"I TER EPENDENr&PADDY�PCEM Eit r" '
� A�G1N-0FSAF r'+� ^`� #' � �'� '' t' x.3�'�i',S�Ug,rm �tr.+,`ti �+,q�`:" .
.E�,tlr ..,. ...i'".: .:• .��vaaaX�. .1"�.�,._.sti�# ! ... ?R...,._...�»..�'y--q[READYAAPLIEDJ_,.. ? s '' K,...�.::. ``.ax*s.,5r. }��,,.=.:
Hip/Ridge Metal Tile Adhesive Allowable Uplift
Design Metal Type Type Placement (psf)
Trim Lock or Trim galvanized,Galvalume",aluminum or clay or 31VITM 2-Component Foam Roof
Lock Plus stainless steel concrete Tile Adhesive AH-160 Interdependent 98
Trim Lock galvanized,Galvalume®or stainless clay or 3MTM Foam Roof Tile Adhesive Interdependent 110
steel concrete RTA-1
Trim Lock aluminum clay or 31VITM Foam Roof Tile Adhesive Interdependent 93
concrete RTA-1
Trim Lock Plus galvanized,Galvalume®,aluminum or clay or 31VITM'Foam Roof Tile Adhesive Interdependent 93
stainless steel concrete RTA-1
Trim Lock galvanized,Galvalume®or stainless clay or TILE BOND-Roof Tile Adhesive Interdependent 152
steel concrete
Trim Lock aluminum clay or TILE BOND"Roof Tile Adhesive Interdependent 82
concrete
Trim Lock Plus galvanized,Galvalume®,aluminum or clay or TILE BOND-Roof Tile Adhesive Interdependent 82
stainless steel concrete
Trim Lock galvanized,Galvalume®or stainless clay or Touch'n Seal StormBond Roof Interdependent 148
steel concrete Tile Adhesive
Trim Lock Aluminum clay or Touch'n Seal StormBond Roof Interdependent 61
concrete Tile Adhesive
Trim Lock Plus galvanized,Galvalume",aluminum or clay or Touch'n Seal StormBond Roof Interdependent 61
stainless steel concrete Tile Adhesive
Exterior Research and Design,LLC. Evaluation Report E10240.08.08-R4
Certificate of Authorization rY9503 FL5374-R4
Revision 4:03/17/2015
Page 5 of 7
I
I
i
I
f
1
'\JTRINITYIERD
6. INSTALLATION: n
i
6.1 The roof deck shall I e minimum 15/32-inch plywood (non-HVHZ)or minimum 19/32-inch plywood(HVHZ)attached in
accordance with FBC Chapter 23 to the satisfaction of the AHJ.
6.2 Hip&Ridge Channe Metal and Trim Lock Channel Metal shall be installed using min. 11 ga.x 1X-inch long x 3/8-inch
head diameter galvl nized annular ring shank nails spaced 6-inch o.c. along both deck:flanges. Fasteners shall be
positioned%-inch fn m the outside edge of each deck-flange,set in a bed plastic roof cement. For FBC HVHZ,refer to
FBC RAS 118,Drawin;13,Detail 3;RAS 119,Drawing 12,Detail 3;or RAS 120,Drawing 15,Detail 3.
6.3 Trim Lock Plus Chanr al Metal shall be installed atop the Approved roof underlayment in continuous 2-inch wide ribbons
of tile adhesive centi red beneath each 1.5-inch wide deck flange. Place the Trim Lock Plus Channel Metal into the wet
adhesive and allow it.to set-up prior to installation of roof tiles.
1
View of Polyset AI.1161 Placement for Trim Lock Plus Channel Metal Installation
6.3.1 It is critical that the b,and between the Trim Lock Plus Channel Metal,the tile adhesive and the underlayment is not
disturbed prior to or di ring;placement of the ridge tiles.
6.3.2 Approved underlayme its are the codified'30/90' system or other FBC Approved roof underlayments listing approved
use of the subject tile Jhesive.
I
1
Exterior Research and Design,I.I.C. Evaluation Report E10240.08.08-R4
Certificate ofAuthodzation#9903 FL
5374-114 Revision 4:03/171201517J2015
Page 6 of 7
i
I
Tf1( IIY ERD
6.4 Tile shall be installed atop the Channel Metal in accordance with the the adhesive manufacturer's Approved,published
jinstallation instructions,subject to the limitations outlined in Section 5 herein. The exposed edges shall be packed and
pointed with Approved mortar or weather blocking adhesive in accordance with FRSA/TRI April 2012 (04-12) or RAS
118,RAS 119,RAS 120 requirements.
Hip/Ridge Tile
Tile Adhesive
ti
-.. Trim Lock Plus
'fir:: L.�r� _ '�•,Z^?�'s
<• Mortar or Weather Block
'� e• Adhesive
r 3'
\`' '•�+'•k-K:. z _ }, ,.'..ir tit �.�.
}'� {'' �_ '+' x, Tile Adhesive
View of Trim Lock Plus Channel Metal Installation after Weather Blocked
6.4.1 Channel Metal shall be free of dust,debris,oils or other bond-breaking substance prior to placement of adhesive.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS:
a
Contact the named CIA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 CIA requirements.
9. QUALITY ASSURANCE ENTITY:
Architectural Testing,Inc. —QUA1844;(717)764-7700
-END OF EVALUATION REPORT-
Exterior Research and Design,I.I.C. Evaluation Report E10240.08.08-R4
Certificate of Authorization#9503 FL5374-R4
Revision 4:03/17/201S
t Page 7 of 7
i
- i
EXTERIOR RESEARCH&DESIGN,LLC.
?` Certificate of Authorization#9503
� TRINITY J ERD 353 CHRISTIAN STREET, UNIT#13
i OXFORD,CT 06478
(203)262-9245
EVALUATION REPORT
Polyglass USA,Inc. Evaluation Report P12060.02.09-R22
150 Lyon Drive FL5259-1126
Fernley, NV 98408 Date of Issuance:02/24/2009
(570)384-1230 Revision 22:03/13/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.
for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted
herein.
DESCRIPTION: Polyglass Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report
ri lative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 14.
repared by: '�,,,�;�;;,«,,,,,r
%
t= The facsimile seal appearing was authorized by Robert Nieminen,
�'• ; P.E.on 03/13/2017. This does not serve as an electronically
•;O�.,p�.. W.Robert J.M.Nieminen,P.E. ofi� _c��c:r�: signed document. Signed,sealed hardcopies have been
a S''... ...k�.�
Florida Registration No.59166,Florida DCA ANE1983 `'.=!�d�;ONE�«�+ transmitted to the Product Approval Administrator and to the
named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
t
i
TRINITY ERD
ROOFING COMPONENT EVALUATION:
r
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the
following sections of the 5`11 Edition (2014) Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
Z. STANDARDS:
Section Property Standard Year
1504.3.1 Wind Uplift FM 4474 2004
1504.3.1 Wind Uplift UL 1897 2004
1504.6 Accelerated Weathering ASTM G154 2006
1504.6 Accelerated Weathering ASTM G155 2005
1507.2.3,1507.3.3,1507.5.3,1507.7.3, Physical Properties ASTM D226 2006
1507.8.3,1507.9.3
1507.2.4,1507.2.9.2,1507.5.3,1507.7.3 Physical Properties ASTM D1970 2009
1507.11.2 Physical Properties ASTM D6164 2005
1507.11.2 Physical Properties ASTM D6222 2008
1507.3.3 Installation Practice FRSA/TRI April 2012 2012
1523.6.5.2.1 Physical Properties TAS 103 1995
3. REFERENCES:
gntiiY Examination Reference Date
FM Approvals(TST 1867) Wind Uplift 3004091 01/12/2000
PRI(TST 5878) Physical Properties PRIO1111 04/08/2002
PRI(TST 5878) Physical Properties PUSA-005-02-01 01/31/2002
PRI(TST 5878) Physical Properties PUSA-013-02-01 12/23/2002
PRI(TST 5878) Physical Properties PUSA-013-02-02 12/23/2002
PRI(TST 5878) Physical Properties PUSA-013-02-03 12/23/2002
PRI(TST 5878) Physical Properties PUSA-018-02-01 07/14/2003
PRI(TST 5878) Physical Properties PUSA-028-02-01 07/13/2005
PRI(TST 5878) Physical Properties PUSA-033-02-01 01/12/2006
PRI(TST 5878) Physical Properties PUSA-035-02-01 09/29/2006
PRI(TST 5878) Physical Properties PUSA-055-02-02 12/10/2007
PRI(TST 5878) Physical Properties PUSA-061-02-02 01/28/2008
PRI(TST 5878) Physical Properties PUSA-076-02-01 02/22/2008
PRI(TST 5878) Physical Properties PUSA-083-02-01 04/14/2008
PRI(TST 5878) Physical Properties PUSA-088-02-01 07/29/2009
MTI(TST 2508) Physical Properties 1X20H7A 04/01/2008
MTI(TST 2508) Physical Properties RX14E8A 01/29/2009
ERD(TST 6049) Physical Properties 11752.09.99-1 02/08/2000
ERD(TST 6049) Wind Uplift 11757.08.01-1 08/13/2001
ERD(TST 6049) Wind Uplift 11776.06.02 01/16/2003
ERD(TST 6049) Physical Properties 02200.07.03 07/14/2003
ERD(TST 6049) Wind Uplift P1740.01.07 01/04/2007
ERD(TST 6049) Physical Properties P5110.04.07-1 04/11/2007
ERD(TST 6049) Wind Uplift P9260.03.08 03/21/2008
ERD(TST 6049) Physical Properties P13450.08.09 08/13/2009
ERD(TST 6049) Wind Uplift P30540.11.09-R1 11/30/2009
ERD(TST 6049) Physical Properties P11030.11.09-1 11/30/2009
ERD(TST 6049) Wind Uplift P11030.11.09-2 11/30/2009
ERD(TST 6049) Physical Properties P11030.11.09-3 11/30/2009
ERD(TST 6049) Physical Properties P33360.06.10 06/25/2010
ERD(TST 6049) Physical Properties P33370.03.11 03/02/2011
Exterior Research and Design,U.C. Evaluation Report 1312060.02.09-1122
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL5259-1126
Polyglass USA,Inc. Revision 22:03/13/2017
Page 2 of 14
I
!!!TRINITY ERD
I
Enti Examination Reference Date
ERD(TST 6049) Physical Properties P33370.04.11 04/26/2011
ERD(TST 6049) Physical Properties P37300.10.11 10/19/2011
ERD(TST 6049) Physical Properties P40390.08.12-1 08/06/2012
ERD(TST 6049) Physical Properties P40390.08.12-2 08/07/2012
ERD(TST 6049) Physical Properties C41420.09.12-3 09/11/2012
ERD(TST 6049) Wind Uplift P39680.03.13 03/04/2013
ERD(TST 6049) Physical Properties P45370.04.13 04/26/2013
ERD(TST 6049) Wind Uplift P1738.02.07-R2 04/29/2013
ERD(TST 6049) Wind Uplift 11757.04.01-1-R1 04/30/2013
ERD(TST 6049) Wind Uplift P41630.08.13 08/06/2013
ERD(TST 6049) Wind Uplift P11751.05.03-R1 11/26/2013
ERD(TST 6049) Wind Uplift P11781.11.03-R1 11/26/2013
ERD(TST 6049) Physical Properties P45270.05.14 05/12/2014
ERD(TST 6049) Physical Properties 6020.07.14-1 09/08/2014
ERD(TST 6049) Physical Properties 6020.09.14-2 09 08 2014
ERD(TST 6049) Physical Properties 6020.09.14-3 09/09/2014
ERD(TST 6049) Physical Properties 6020.09.14-4 09/08/2014
ERD(TST 6049) Physical Properties 6020.09.14-5 09/08/2014
ERD(TST 6049) Physical Properties 6020.09.14-6 09/08/2014
ERD(TST 6049) Physical Properties P46520.10.14 10/03/2014
ERD(TST 6049) Physical Properties P44360.10.14 10/07/2014
ERD(TST 6049) Physical Properties P43290.10.14 10/17/2014
ERD(TST 6049) Physical Properties PLYG-SC7550.03.15 03/24/2015
ERD(TST 6049) Physical Properties P40390.04.15 04/03/2015
ERD(TST 6049) Physical Properties PLYG-SC8080.05.15-1 05/20/2015
ERD(TST 6049) Wind Uplift PLYG-SC8905.05.16-1 05/17/2016
ERD(TST 6049) Physical Properties PLYG-SC8080.07.16 07/16/2016
ERD(TST 6049) Wind Uplift PLYG-SC12025.10.16 10/12/2016
ERD(TST 6049) Physical Properties PLYG-SC11900.03.17 03/10/2017
ICC-ES(EVL 2396) IBC Compliance ESR-1697 11/01/2014
Miami-Dade(CER 1592) HVHZ Compliance NOA 14-0717.08 01/22/2015
Polyglass USA Manufacturing Affidavit Products Current 02/18/2009
Polyglass USA P/L Affidavit Mule-Hide Cross Ltg 03/01/2008
Polyglass USA Materials Affidavit Polystick SA Compound 08/18/2011
UL,LLC.(QUA9625) Quality Control Service Confirmation Exp.04/24/2018
4. PRODUCT DESCRIPTION:
41 Mechanically Fastened Underlayments
. _. .. ...,
4.1.1 Elastobase is a fiberglass reinforced,SBS modified bitumen base sheet.
4.1.2 Elastobase P is a polyester-reinforced,SBS modified bitumen base sheet.
4.1.3 Polyglass G2 Base is a fiberglass-reinforced,asphaltic base sheet.
4.1.4 Polyglass APP Base is a fiberglass-reinforced,APP modified bitumen base sheet.
4 2 Self Adher�eg Und"layments;
_._.,
4.2.1 Polystick MTS is a nominal 60-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,surfaced
with polyolefinic film surface;meets TAS 103.
4.2.2 Polystick MTS PLUS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced,
surfaced with poly-film surface;meets TAS 103.
4.2.3 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,with an
aggregate surface;meets ASTM D1970.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R22
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION F1.5259-1126
Polyglass USA,Inc. Revision 22:03/13/2017
Page 3 of 14
I
C
CI
\j TRIIeIITY ERD
4.2.4 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,with a
polyester fabric surface; meets ASTM D1970 and TAS 103.
4.2.5 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester
reinforced,with a granular surface;meets ASTM D1970 and TAS 103.
4.2.6 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/m2 polyester
fabric surface;meets ASTM D1970 and TAS 103.
4.2.7 Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet (FR) are polyester
reinforced,APP modified bitumen cap sheets;meet ASTM D6222.
4.2.8 Polystick Dual Prolm is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass
reinforced,with a polyester fabric surface;meets ASTM D1970.
4.2.9 Polystick Tile Pro' is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass
reinforced,with a polyester fabric surface;meets ASTM D1970 and TAS 103.
4.2.10 Polystick MU-X is a nominal 54-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass
reinforced,with a polypropylene film surface; meets AC188 and physical requirements of ASTM D1970 (See Section
S.8).
4 3 �_ Mechanically Fastened and/or Boned Underlayments r
.a
4.3.1 Elastoflex G TU is a polyester reinforced, modified bitumen tile underla ment composed of an sand-surfaced SBS
modified bitumen back-side and granule-surfaced APP modified bitumen top-side. Elastoflex G TU is for use as an
alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April
2012 (04-12) beneath mechanically fastened tile roof systems or Hot Asphalt applied "Cap Sheet" in the `Two Ply
System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened or adhered tile roof systems.
4.3.2 Elastoflex S6 G and Elastoflex S6 G FR are polyester reinforced,SBS modified bitumen cap sheets;meet ASTM D6164.
Elastoflex S6 G and Elastoflex S6 G FR are for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380,
Class M)in the"Single Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened tile roof systems.
Elastoflex S6 G is for use as an alternate to Hot Asphalt applied "Cap Sheet" in the`Two Ply System"from FRSA/TRI
April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Elastoflex S6 G FR is for use as an
alternate to Hot Asphalt applied "Cap Sheet" in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath
mechanically fastened the roof systems.
4.3.3 Polyflex G and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets; meet ASTM D6222.
Polyflex G is for use as an alternate to Heat Applied "Cap Sheet" in the`Two Ply System"from FRSA/TRI April 2012
(04-12) beneath mechanically fastened or adhered the roof systems. Polyflex G FR is for use as an alternate to Heat
Applied "Cap Sheet" in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile
roof systems.
S. LIMITATIONS:
SA This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
Exterior Research and Design,I.I.C. Evaluation Report P12060.02.09-1122
Certificate ojAuthorization#9503 FBC NON-HVHZ EVALUATION FL5259-R26
Polyglass USA,Inc. Revision 22:03/13/2017
Page 4 of 14
I
\j TRINITY 1 ERD
5.5 Allowable Roof Covers:
` t TABLE 1 X ROOF COVER OPTIONS l '
Underlayment Asphalt Shingles Nail-On Tile Foam-On Tile Metal wood Shakes Slate
&Shingles
Elastobase Yes Yes Yes Yes Yes Yes
(Base Sheet in 2-ply system) (Base Sheet in 2-ply system)
Elastobase P Yes Yes Yes Yes Yes Yes
(Base Sheet in 2-ply system) (Base Sheet In 2-ply system)
Polyglass G2 Base No Yes Yes No No No
(Base Sheet in 2-ply system) (Base Sheet in 2-ply system)
Yes Yes
Polyglass APP Base No (Base Sheet in 2-ply system) (Base Sheet n 2-ply system) No No NO
Polystick MTS Yes Yes No Yes Yes Yes
Polystick MTS PLUS Yes Yes No Yes Yes Yes
Polystick IR-Xe Yes No No No Yes Yes
Polystick TU P Yes Yes Yes (See 5.5.1) No Yes Yes
PolystickTU Plus Yes 7 e5 - Yes (See 5.5.1) Yes Yes Yes
wR*stic-k1&U_Max2=mwNo Yes Yes (See 5.5.1) Yes No No
Polystick Dual Pro Yes Yes No Yes Yes Yes
Polystick Tile Pro Yes Yes Yes (See 5.5.1) Yes Yes Yes
Polystick MU-X Yes No No Yes Yes Yes
Elastoflex S6 G Yes Yes Yes (See 5.5.1) No Yes Yes
Elastoflex S6 G FR Yes Yes No No Yes Yes
Elastoflex G TU Yes Yes Yes (See 5.5.1) No Yes Yes
Polyflex G Yes Yes Yes (See 5.5.1) No Yes Yes
Polyflex G FR I Yes Yes No No Yes Yes
Polyflex SAP or SAP FR Yes Yes Yes (See 5.5.1) No Yes Yes
Mule-Hide SA-APP Cap Sheet Yes Yes Yes (See 5.5.1) No Yes Yes
or SA-APP Cap Sheet(FR)
5.5.1 "Foam-On Tile"is limited to use of the following Approved tile adhesives/underlayment combinations.
;x TABiE lA iAL101NABLE TILE'ADHESIVE/UNDERLAYMENT COMBI(VATlONS
Adhesive Florida Product Underlayments
Approval
Convenience Products'Touch'n FL14506 PolystickTU Plus,PolystickTU Max
Seal Storm Bond Roof Tile Adhesive
Dow TileBond' FL717 Polystick TU P,Polystick TU Plus,Polyflex SAP or Tile Pro
PolystickTU P,PolystickTU Plus,PolystickTU Max,Polystick Tile Pro,
ICP Adhesives Polyset°AH-160 FL6332 Elastoflex G TU,Elastoflex S6 G,Polyflex G,Polyflex SAP,Polyflex SA Cap
FR,Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR)
Polystick TU P,Polystick TU Plus,Polystick TU Max,Polystick Tile Pro,
ICP Adhesives Polyset®RTA-1 FL6276 Elastoflex G TU,Elastoflex S6 G,Polyflex G,Polyflex SAP,Polyflex SA Cap
FR,Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR)
Polyglass PolyLok Roof Tile FL17855 Polystick TU Plus or Polystick TU Max
Adhesive
1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R22
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL5259-R26
Polyglass USA,Inc. Revision 22:03/13/2017
Page 5 of 14
C_)o
TRINITY I ERD
5.6 Allowable Substrates:
5.6.1 Direct-Bond to Deck:
Polystick(all variations),Dual Pro,Tile Pro, Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet
(FR)self-adhered to:
➢ New untreated plywood;ASTM D41 primed new untreated plywood; Existing plywood;ASTM D41 primed existing
plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed
Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIP System" Panels
(designed and installed to meet wind loads for project).
Note: Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or
OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes.
Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
➢ ASTM D41 primed structural concrete.
Polyflex G or Polyflex G FR torch-applied to:
➢ ASTM D41 primed structural concrete.
5.6.2 Bond-to-Insulation:
Polystick(all variations), Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR)self-adhered
to:
➢ ASTM C1289, Type 11, Class 1 polyisocya nu rate or Type V polyisocyanurate-composite insulation; Dens Deck
DuraGuard;Dens Deck Prime;or SECUROCK Gypsum-Fiber Roof Board.
Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
➢ Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board.
Polyflex G or Polyflex G FR torch-applied to:
➢ ASTM D41 primed structural concrete;Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on tile
systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of
the insulation/underlayment system in accordance with FBC Section 1504.3.1.
5.6.3 Bond to Mechanically Attached Base Laver:
Polystick (all variations), Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR) Dual Pro or
Tile Pro self-adhered to:
➢ ASTM D226,Type I or II felt;Elastobase;Elastobase P or Mule-Hide Nail Base.
Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
➢ ASTM D226,Type I or II felt;Elastobase;Elastobase P,Mule-Hide Nail Base or Polyglass G2 Base.
Polyflex G or Polyflex G FR torch-applied to:
➢ Elastobase;Elastobase P,Mule-Hide Nail Base,Polyglass G2 Base or Polyglass APP Base.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam-on tile systems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2012(04-12),Appendix A,Table 1,or as listed in Section 5.6.4 herein, or as tested in
accordance with FBC Section 1504.3.1.
5.6.4 Wind Resistance for Underlavment Svstems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam-on tile systems, where the underlayment
forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012(04-12)and are used in foam-on tile applications. Maximum Design Pressure is the
result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure
divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012(04-
12),Appendix A,Table 1A or FBC 1609 for determination of design wind loads.
Exterior Research and Design,U.C. Evaluation Report P12060.02.09-R22
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL5259-1126
Polyglass USA,Inc. Revision 22:03/13/2017
Page 6 of 14
F)o
TRINITY ERD
5.6.4.1 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: None
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.2 Maximum Design Pressure=-97.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x
1%"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c.
5.6.4.3 Maximum Design Pressure=-105 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: WB-3000
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x
1Y."ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c.
5.6.4.4 Maximum Design Pressure=-135 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional)PG100 or ASTM D41
Joints: Min.4-inch wide strips of Elastoflex SA-V over all plywood joints.
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.5 Maximum Design Pressure=-315 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P, Polystick TU Plus,Polystick TU Max,Tile Pro, Polyflex SAP, Polyflex SAP FR,Mule-Hide SA-APP Cap
Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.6 Maximum Design Pressure=-622.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.7 Maximum Design Pressure=-30.0 psf*:
Deck: Min.15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.8 Maximum Design Pressure=-37.5 psf*:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R22
Certificate ofAathori:ation#9503 FBC NON-HVHZ EVALUATION FL5259-R26
Polyglass USA,Inc. Revision 22:03/13/2017
Page 7 of 14
I
f
TRINITY ERD
5.6.4.9 Maximum Design Pressure=-37.5 psf*:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One(1)or two(2)layers ASTM D226,Type II felt
Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt.
I
5.6.4.10 Maximum Design Pressure=-45 psf*:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One(1)layer ASTM D226,Type II felt
Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c.at the 2-inch wide side laps and 4-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elastoflex G TU,applied in full mopping of hot asphalt.
5.6.4.11 Maximum Design Pressure.=-45 psf*:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Two(2)layers ASTM D226,Type II felt
Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 9-inch c.c.at the 2-inch wide side laps and 9-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS PLUS,self-adhered
Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elastoflex G TU or Elastoflex 56 G,applied in full mopping of hot
asphalt.
5.6.4.12 Maximum Design Pressure=-45 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c.at the 2-inch wide side laps and 18-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.13 Maximum Design Pressure=-52.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.14 Maximum Design Pressure=-52.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.15 Maximum Design Pressure=-52.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
Exterior Research and Design,U.C. Evaluation Report P12060.02.09-R22
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL5259-R26
Polyglass USA,Inc. Revision 22:03/13/2017
Page 8 of 14
I
TRINITY I ERD
5.6.4.16 Maximum Design Pressure=-60 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.17 Maximum Design Pressure=-60 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: CMG#12 Standard Roofgrip with CMG Flat Bottom Metal Plates
Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.18 Maximum Design Pressure=-67.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base(requires use of torch-applied underlayment)
Fasteners: 12 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch-applied or Polyflex G, torch-
applied.
5.6.4.19 Maximum Design Pressure=-75 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base(requires use of torch-applied underlayment)
Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with CMG 3"Galvalume Steel Plates,CMG Roofgrip#14 with
CMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: 10-inch o.c.at the 4-inch wide side laps and 10-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch-applied or Polyflex G, torch-
applied.
5.6.4.20 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.21 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: OMG#12 Standard Roofgrip or CMG#14 Heavy Duty with OMG 3"Round Metal Plates or CMG Flat Bottom Metal
Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.22 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface)
Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt.
Exterior Research and Design,U.C. Evaluation Report P12060.02.09-R22
Certificate of Authorization#9503 FBC NON-HVH2 EVALUATION FL5259-1126
Polyglass USA,Inc. Revision 22:03/13/2017
Page 9 of 14
• i `
TRINITY ERD
5.6.4.23 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
j Base Sheet: Polyglass G2 Base or Polyglass APP Base(requires use of torch-applied underlayment)
Fasteners: Dekfast#14 with Dekfast Hex plates, CMG#14 HD with OMG 3"Galvalume Steel Plates,OMG Roofgrip#14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap
j Fasteners
Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or torch-applied or Polyflex G, torch-
applied.
5.6.4.24 Maximum Design Pressure=-97.5 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c.at the 4-inch wide side laps and 4-inch o.c.at four(4)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS PLUS,self-adhered
Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.25 Maximum Design Pressure=-105 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.26 Maximum Design Pressure=-112.5 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer at all tin-caps
Base Ply: Polystick MTS PLUS,self-adhered
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.27 Maximum Design Pressure=-120 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.28 Maximum Design Pressure=-120 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface)
Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt.
5.6.4.29 All other direct-deck, adhered Polyglass underlayment systems beneath foam-on tile systems carry a Maximum
Design Pressure of-45 psf.
Exterior Research and Design,U.C. Evaluation Report P12060.02.09-R22
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL5259-1126
Polyglass USA,Inc. Revision 22:03/13/2017
Page 10 of 14
I
i
TRINITY ERD
5.6.4.30 For mechanically attached Base Sheet,the maximum design pressure for the selected assembly shall meet or exceed
that required under FRSA/TRI April 2012(04-12),Appendix A,Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design
pressure determined in accordance with FBC 1609. In this case,Zones 2 and 3 shall employ an attachment density
designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are
ANSI/SPRI WDi, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked
with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January
2016)for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30-days
after installation.
Polystick IR-Xe or Polystick MU-X shall not be left exposed for longer than 90-days after installation.
Polystick MTS, MTS PLUS,TU P,TU Plus,TU Max, Dual Pro,Tile Pro or Elastoflex G TU shall not be left exposed for
longer than 180-days after installation.
Polyflex SAP or SAP FR, or Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure
limitation, unless the prepared roof covering is to be adhesive-set tile, in which case the maximum exposure is 30
days.
Elastoflex S6 G or Elastoflex S6 G FR or Polyflex G or Polyflex G FR does not have an exposure limitation, unless the
prepared roof covering is to be adhesive-set tile (Elastoflex S6 G or Polyflex G only), in which case the maximum
exposure is 180 days.
5.8 Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226
roofing felt in a dry condition,tested at standard laboratory conditions. Agreement between purchaser and seller,as
set forth in Section 5.3,Note 1 of ASTM D1970-09,should be established as to slip resistance.
6. INSTALLATION:
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application,and prime the substrate(if applicable).
41 Elastobase;Elastobase P or aVlule H Ide Nail Base
_.
6.3.1 Shall be installed in compliance with the codified requirements for ASTM D226,Type II underlayment in FBC Sections
1507 for the type of prepared roof covering to be installed.
6.3.2 Non-Tile Applications:
Reference is made to the current edition of the NRCA Steep-slope Roofing Manual and ARMA recommendations for
installing shingle underlayments and flashings
Elastobase, Elastobase P or Mule-Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP or SAP FR,
Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), Dual Pro or Tile Pro, self-adhered, Elastoflex G TU,
Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR,torch applied.
6.3.3 Tile Applications:
Reference is made to FRSA/TRI April 2012(04-12)Installation Manual and Table 1 herein,using the instructions noted
above as a guideline.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R22
Certificate ofAuthorizotion#9503 FBC NON-HVHZ EVALUATION FL52S9-R26
Polyglass USA,Inc. Revision 22:03/13/2017
! Page 11 of 14
i
I
TRINITY I ERD
Its= MaxPyflex SAP,Poly O lde SA APP`Cap Street or Mule Hlde SA APP Cap Sheet(fR) _
6.4.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Sections 1507
for the type of prepared roof covering to be installed.
Note: Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM
D226 roofing felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and
seller,as set forth in Section 5.3,Note 1 of ASTM D1970-09,should be established as to slip resistance.
6.4.2 Direct-to-Deck with Mechanically Fastened Roof Covers:
All self-adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FIR and Mule-Hide SA-APP
Cap Sheet or SA-APP Cap Sheet(FR)should be back-nailed in selvage edge seam in accordance with Polyglass/Mule-
Hide Back Nailing Guide. Nails shall be corrosion resistant,11 gauge ring-shank type with a minimum 1-inch diameter
metal disk or Simplex-type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back-nailed
using the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of membrane.
The head lap membrane is to cover the area being back-nailed.
All seal-lap seams (selvage laps) must be
firmly rolled with a minimum 28 lb. hand ' 4
roller to ensure full contact and adhesion.
For Dual Pro and Tile Pro, align the edge of
the top sheet to the end of the glue pattern +
(the sheet will overlap the fabric). -
Yt
z.
View of Ovelap Seam of Dual Pro and Tile Pro
All over-fabric and over-granule end-laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified
Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap.
Polystick TU Plus,Dual Pro and Tile Pro may not be used in any exposed application such as crickets,exposed valleys,
or exposed roof to wall details
Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or
Polyglass PG500 Modified Cement to the area in need of repair, followed by a minimum 6 x 6 inch patch of the
Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be
installed in a water shedding manner.
All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a
minimum of 40-lb weighted-roller or,on steep slopes, use of a stiff broom with approximately 40-lbs of load applied
for the field membrane. Hand rollers are acceptable for rolling of patches,laps(min.28 lb roller)or small areas of the
roof that are not accessible to a large roller or broom.
6.4.3 Tile Applications(not allowed for Polystick IR Xe or Polystick MU X):
Reference is made to FRSA/TRI April 2012(04-12)Installation Manual and Table 1 herein,using the instructions noted
above as a guideline.
For mechanically fastened tile roofing over 2-ply system,consisting of Base Sheet and self-adhering top sheet(s), Base
Sheet fastening shall be not less than FRSA/TRI April 2012(04-12),Table 1.
For adhesive-set tile applications,refer to Section 5.6.4 herein.
For nail-on tile systems over Polystick MTS,battens are required for loading/staging of the tile.
For nail-on tile systems over Polystick MTS PLUS:
➢ Battens are required for loading/staging of lugged tile regardless of slope.
➢ Battens are required for loading/staging of flat tile at slopes in excess of 5:12.
Exterior Research and Design,U.C. Evaluation Report P12060.02.09-R22
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL5259-1126
Polyglass USA,Inc. Revision 22:03/13/2017
Page 12 of 14
I
TRINITY I ERD
6.4.4 Two(2)Ply UnderlaVment Systems:
Polystick MTS or MTS PLUS followed by Polystick MTS,MTS PLUS,TU P,TU Plus,TU Max,Tile Pro,MU-X or Polyflex
SAP is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with
the top-layer material. This is not a requirement,but is allowable if a 2-ply underlayment system is desired.
Polystick MTS PLUS followed by Polystick TU P,TU Plus,TU Max,Tile Pro or Polyflex SAP is allowable for use under
foam-on tile systems. Limits of use are those associated with the top-layer material. This is not a requirement,but is
allowable if a 2-ply underlayment system is desired.
6 5 Elastoflex G TU,ElastofldkU G or„Elastoflex 56 GFR
r
ti
6.5.1 Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR shall be installed in compliance with current Polyglass published
installation requirements. For use in tile applications:
✓ Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the"Single
Ply System"from FRSA/TRI April 2012(04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" in the"Two Ply System"from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex S6 G is for use as an alternate to"Mineral Surface Roll Roofing"(ASTM D6380,Class M)in the"Single Ply
System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" in the"Two Ply System"from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex S6 G FR is for use as an alternate to"Mineral Surface Roll Roofing"(ASTM D6380,Class M)in the"Single
Ply System"from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied"Cap Sheet" in the"Two Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened tile
roof systems.
6.5.2 For hot-asphalt-applications,Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR shall be fully asphalt-applied to the
substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end-laps minimum 6-inch wide, off-set
minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt
with asphalt extending approximately 3/8-inch beyond the lap edge.
6 6 Polyflex G or Polyflex G FR ° , 4
6.6.1. Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements.
For use in tile applications:
✓ Polyflex G.is for use as an alternate to the Heat Applied"Cap Sheet" in the"Two Ply System"from FRSA/TRI April
2012(04-12)beneath mechanically fastened or adhered tile roof systems(Base Sheet Limited per 5.6.3).
✓ Polyflex G FR is for use as an alternate to the Heat Applied applied "Cap Sheet" in the "Two Ply System" from
FRSA/TRI April 2012(04-12)beneath mechanically fastened tile roof systems(Base Sheet Limited per 5.6.3).
6.6.2 Polyflex G or Polyflex G FR shall be fully torch-applied to the substrates noted in Section 5.6. Side laps shall be
minimum 3-inch and end-laps minimum 6-inch wide, off-set minimum 3 feet from course to course. Side and end
laps shall be fully heat-welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap
edge.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R22
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL5259-RZ6
Polyglass USA,Inc. Revision 22:03/13/2017
Page 13 of 14
i
TRINITY I ERD
6.7 Tile Staging:
6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to
Polyglass published requirements for the staging.
6.7.2 Battens and/or Counter-battens,as required by the tile manufacturer and FRSA/TRI April 2012(04-12) must be used
on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or nail-
boards,to prevent tile sliding and/or damage to the underlayment during the loading process.
6.7.3 For nail-on tile systems over Polystick MTS,battens are required for loading/staging of the tile.
6.7.4 For nail-on the systems over Polystick MTS PLUS:
➢ Battens are required for loading/staging of lugged tile regardless of slope.
➢ Battens are required for loading/staging of flat tile at slopes in excess of 5:12.
6.7.5 The minimum cure time after installation of self-adhering membranes and before loading of roofing tiles is forty-eight
(48)hours.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C.Rule 61G20-3 Q4 requirements.
9. QUALITY ASSURANCE ENTITY:
UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT-
Exterior Research and Design,I.I.C. Evaluation Report P12060.02.09-R22
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL5259-R26
Polyglass USA,Inc. Revision 22:03/13/2017
j Page 14 of 14
i
I
EXTERIOR RESEARCH&DESIGN,LLC.
Certificate of Authorization#9503
TR�N�N I ERD 353 CHRISTIAN STREET,UNIT#13
QOOXFORD,CT 06478478
THESE PLANO'AN ►all PROPOSEW RI( PHONE:(203)262-9245
ARE SU13J CT T O AN'!(()j CtCTJ0NS - FAX:(203)262-9243
EVALUATION REPORT REQUIRED FOY HELD THAT -`'
I11"�w i .. Entegra Roof Tile,$W BE NECESSARY IN CAVIRR dEvaluat�n Report E39310.11.11-2-R4
r.NTEGRA 1289 NE 9 Avenuu&nY ! H t'bI L f;QpF - `r FL7804-R9
R O O F T I L E Okeechobee, FL 34972 """"'Date of Issuance:11/02/2011
Revision 4:04/18/2016
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code(non-
HVHZ)sections noted herein.
DESCRIPTION: Entegra Concrete Roof Tiles(non-HVHZ jurisdictions)
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6. CONCE'�'FD rAS�'E RS l�R'P���f•1lifllif°ENTS
Prepared by: gtstttlr;!zr,,'
ARE 1�� fF�rd�'IILI OF W
Robert J.M.Nieminen,P.E. ',0�••p :•. ;�.T,+?�,' The facsimile seal appearing was authorized by Robert Nleminen,
oS•;C ,,,. P.E.on 04/18/2016.This does not serve as an electronically signed
Florida Registration No.59166,Florida DCA ANE1983 ;'�°SON�Lti,`< document.Signed,sealed hardcopies have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report, previous ver ions thereof,is/was
�16)�()
used for permitting or design guidance unless retained
specifically for that purpose. (
ST. LUCIE COUNT
BUILDING DIVISIO V
G F_VIEE%Fd2�
FOR O®9fI� A
��, El
REVIEWED BY " v L
DATE F--
PLANS AND PEPWI i
MUST 61; KrIP 'ON dOD OR
NO INSPCC'PION Wli,lL aR MADE
i
i
TRINITY I ERD
ROOFING SYSTEM EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Roofing Tiles
Compliance Statement: Entegra Concrete Roof Tiles, as produced by Entegra Roof Tile, LLC, have demonstrated
compliance with the following sections of the Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth
herein.
2. STANDARDS:
Section Property Standard Year
1507.3.5,R905.3.5 Physical Properties ASTM C1492 2003
1507.3.7,R905.3.7 Attachment Requirements FRSA/TRI April 2012(04-12) 2012
1711.2.1 Overturning Moment SSTD 11 1997
3. REFERENCES:
Entity Examination Reference Date
ATL(TST3782) Physical Properties RT0615.01-11 06/28/2011
ATL(TST3782) Physical Properties RT0615.02-11 06/28/2011
ATL(TST3782) Physical Properties RT0615.03-11 06/28/2011
ATL(TST3782) Physical Properties RT0615.04-11 06/28/2011
ATL(TST3782) Physical Properties RT0615.05-11 06/28/2011
ATL(TST3782) Physical Properties RT0316.01-12 05/31/2012
ATL(TST 3782) Physical Properties RT1103.01-15 11/07/2015
ATL(TST 3782) Physical Properties RT1103.02-15 11/07/2015
ATL(TST 3782) Physical Properties RT1103.03-15 11/07/2015
ATL(TST 3782) Physical Properties RT1103.04-15 11/07/2015
ATL(TST 3782) Physical Properties RT1103.05-15 11/07/2015
PRI(TST5878) Physical Properties ESI-001-02-01 11/06/2006
PRI(TST5878) Physical Properties ESI-002-02-01 11/06/2006
PRI(TST5878) Physical Properties ESI-003-02-01 11/06/2006
PRI(TST5878) Physical Properties ESI-004-02-01 11/06/2006
PRI(TST5878) Physical Properties ESI-005-02-01 12/12/2006
PRI(TST5878) Physical Properties HRT-023-02-01 11/19/2007
PRI(TST5878) Physical Properties HRT-026-02-01 01/08/2008
Tile Roof Institute SSTD 11 Membership Confirmation Current
PRI(QUA9110) Quality Assurance Inspection Report 11/04/2015
Exterior Research and Design,U.C. Evaluation Report E39330.11.11-2-R4
Certificate of Authorization 89503 FL7804-119
Revision 4:04/18/2016
Page 2 of 6
I
i
i
I
TRINITY I ERD
4. PRODUCT DESCRIPTION:
4.1 BERMUDA FLAT PLANTATION FLAT nd HORIZON FLAT are ASTM C1492,Type III(low-profile)concrete roof tiles.
r 16'- _
1-1/T4'
T
10,
i Y
i
i
------16'-mil
z•
10, /
Y
Bermuda Flat
< >
Plantation Flat
17-1/4"
13" /
Horizon Flat
Exterior Research and Design,U.C. Evaluation Report E39310.11.11-2-R4
Certificate of Authorization#9503 F1.7804-119
Revision 4:04/18/2016
Page 3 of 6
i
��TRINIWIERD
4.2 BELLA HIGH"S",ESTATE"S"and HACIENDA are ASTM D1492,Type II(medium-profile)concrete roof tiles.
I
16 21" 13-4"
Bella High"S"
Nail Holes
•
•
16l
l3
Estate"S"
0
0
i
�3
Hacienda
Exterior Research and Design,LLC. Evaluation Report E39310.11.11-2-R4
Certificate of Authorization#9503 FL7804-R9
Revision 4:04/18/2016
Page 4 of 6
i
TRINITY I ERD
4.3 GALENA SPANISH"S"and REGAL are ASTM C1492,Type I (high-profile)concrete roof tiles.
I
I
I
17
101,
Galena Spanish"S"
a e
13 1/a"
Regal
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire classification is not part of this evaluation; refer to FBC Section 1505, Exception 2 or current Approved
Roofing Materials Directory for fire rating of this product.
5.4 Underlayment shall be that approved by Entegra Roof Tile, which holds Florida Local or Statewide Product
Approval for use with tile roofing systems. The underlayment Product Approval shall specify allowable
method(s) of tile installation (mechanical attachment, mortar-set and/or adhesive-set) for use with the
specific underlayment. For mortar-set or adhesive-set tile roofing applications, the underlayment Product
Approval shall specify attachment methods for the underlayment system to resist wind uplift design loads in
accordance with Table 1A of FRSA/TRI April 2012(04-12).
5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building
Code and F.A.C.Rule 61G20-3.
Exterior Research and Design,I.I.C. Evaluation Report E39330.11.11-2-R4
Certificate of Authorization#9503 F1.7804-119
Revision 4:04/18/2016
Page 5 of 6
I '
I r
1
I
��TRINrryfERD
6. INSTALLATION:
6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar-set or adhesive-set. Installation shall
comply with manufacturer's current published instructions, but not less than the requirements of FBC
Section 1507.3,the FRSA/TRI Florida High Wind Concrete and Clay Tile Installation Manual, 5`h Edition and,
for mortar-set or adhesive-set applications,the mortar or adhesive manufacturer's Product Approval.
6. Attachment:
Mechanically Attached Tile:
Wind load resistance shall be in accordance with Table 3 of FRSA/TRI April 2012 (04-12) to resist the Uplift
Moment determined in Table 2A or 213 of FRSA/TRI April 2012(04-12).
Mortar-Set or Adhesive-Set Tile:
Wind load resistance shall be in accordance with FBC Section 1609.5.3 in conjunction with the mortar or
adhesive manufacturer's Product Approval.
Hip and Ridge Tile:
Tile shall be installed in accordance with FRSA/TRI April 2012(04-12). For hip and ridge tile installations atop
hip and ridge metal, refer to the hip and ridge metal manufacturer's Product Approval (e.g., FL5374) or test
report in accordance with SSTD 11 for allowable loads to resist those determined in accordance with Table
1A of FRSA/TRI April 2012(04-12).
7. LABELING:
7.1 Each unit shall bear the imprint and/or identifiable marking of the manufacturer's name or logo. Tile lots
shall be labeled in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. Rule 61G20-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
PRI Construction Materials Technologies,LLC.—QUA9110;(813)621-5777
-END OF EVALUATION REPORT-
Exterior Research and Design,I.I.C. Evaluation Report E39310.11.11-2-R4
Certificate of Authorization#9503 FL7804-R9
Revision 4:04/18/2016
Page 6 of 6
I
i
•
3 : ,
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.sov/economy
ICP Adhesivesand Sealants,Inc. O �I T LI
12505 NW 44'Street �—✓� ` (!./ V
Coral Springs,FL.33065
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ On areas other than Miami Dade County)reserve the right to have this product
or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: ICP Adhesives Polyset®AH-160
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
•TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA 16-0315.01 and consists of pages 1 through 11.
The submitted documentation was reviewed by Alex Tigera
Ful 1k.,5!I
LY
NOA No.: 17-0322.03
MIAMI•DAb;COUNTY Expiration Date: 05/10/22
Approval Date:04/27/17
Page 1 of 11
I
' i
ROOFING COMPONENT APPROVAL:
Category: Roofing
Sub Category: Roof tile adhesive
Materials: Polyurethane
SCOPE:
This approves ICP Adhesives Polyset®AH-160 as manufactured by ICP Adhesives and Sealants,Inc.as described
in this Notice of Acceptance.For the locations where the design pressure requirements,as determined by applicable
building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing
Application Standard RAS 127. For use with approved flat,low, and high profile roof tile systems using ICP
Adhesives Polyset®AH-160.
PRODUCTS MANUFACTURED BY APPLICANT:
Product Dimensions Test Product Description
Specifications
ICP Adhesives N/A TAS 101 Two component polyurethane foam adhesive
Polyset®AH-160
ICP Adhesives*Foam N/A Dispensing Equipment
Nip
Dispenser RTF1000
ICP Adhesives ProPack® N/A Dispensing Equipment
30& 100
PRODUCTS MANUFACTURED BY OTHERS:
Any Miami-Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment
resistance values with the use of ICP Adhesives Polyset®AH-160 roof tile adhesive.
MANUFACTURING LOCATION: ^
1. Tomball,TX.
PHYSICAL PROPERTIES:
Prove Provertv Test Results
Density ASTM D 1622 1.6 lbs./ft.3
Compressive Strength ASTM D 1621 18 PSI Parallel to rise
12 PSI Perpendicular to rise
Tensile Strength ASTM D 1623 • 28 PSI Parallel to rise
Water Absorption ASTM D 2127 0.08 Lbs./Ff
Moisture Vapor Transmission ASTM E 96 3.1 Perm/Inch
Dimensional Stability ASTM D 2126 +0.07%Volume Change @-40°F.,2 weeks
+6.0%Volume Change @1580F., 100%Humidity,2
weeks
Closed Cell Content ASTM D 2856 86%
Note: The physical properties listed above are presented as typical average values as determined by
accepted ASTM test methods and are subject to normal manufacturing variation.
NOA No.: 17-0322.03
MIAMI•DAD;COUNTY Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 2 of 11
I
i
I
i
II ,
i
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
Center for Applied Engineering #94-060 TAS 101 04/08/94
257818-IPA TAS 101 12/16/96
25-7438-3 SSTD 11-93 10/25/95
' 25-7438-4
25-7438-7 SSTD 11-93 11/02/95
25-7492 SSTD 11-93 12/12/95
Miles Laboratories ° NB-589-631 ASTM D 1623 02/01/94
Polymers Division
Ramtech Laboratories,Inc. 9637-92 ASTM E 108 04/30/93
Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94
01-6739-062b[l] ASTM E 84 01/16/95
Trinity Engineering 7050.02.96-1 TAS 114 03/14/96
P36700.04.12 ASTM D 1623 04/18/12
P39740.02.12 TAS 101 02/21/12
TAS 123
Celotex Corp. Testing Services 528454-2-1 TAS 101 10/23/98
528454-9-1
528454-10-1
520109-1 TAS 101 12/28/98
520109-2
520109-3
520109-6
520109-7
520191-1 TAS 101 03/02/99
520109-2-1
LIMITATIONS:
1. Fire classification is not part of this acceptance.Refer to the Prepared Roof Tile Assembly for fire rating.
2. ICP Adhesives Polyset®AH-160 shall solely be used with flat,low,&high tile profiles.
3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset®AH-160 roof tile adhesive
with their tile assemblies shall test in accordance with TAS 101.
audit in accordance with the Florida Building 5. All products listed herein shall have a quality assuranceg Code and
Rule 61 G20-3 of the Florida Administrative Code.
. NOA No.: 17-0322.03
MIAMI•DADE COUNTY Expiration Date: 05/10/22
Approval Date:04/27/17
Page 3 of 11
°
I
INSTALLATION:
1. ICP Adhesives Polyset®AH-160 may be used with any roof tile assembly having a current NOA that lists
attachment resistance values with the use of ICP Adhesives Polyset®AH-160.
2. ICP Adhesives Polyset®AH-160 shall be applied in compliance with the Component Application section and the
corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP
Adhesives Polyset®AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value
determined in compliance with Miami-Dade County Roofing Application Standards RAS 127. The adhesive
attachment data is noted in the roof tile assembly NOA.
3. ICP Adhesives Polyset®AH-160 and its components shall be installed in accordance with Roofing Application
Standard RAS 120,and ICP Adhesives and Sealants,Inc.'s Operating Instruction and Maintenance Booklet.
4. Installation must be by a Factory Trained'Qualified Applicator'approved and licensed by ICP Adhesives and
Sealants,Inc. ICP Adhesives and Sealants,Inc. shall supply a list of approved applicators to the authority having
jurisdiction.
5. Calibration of the ICP Adhesives Foam Dispenser RTF1000 dispensing equipment is required before application
of any adhesive. The mix ratio between the"A" component and the"B" component shall be maintained between
1.0-1.15 (A): 1.0(B).
6. ICP Adhesives Polyset®AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF1000 or ICP
Adhesives ProPack®30& 100 dispensing equipment only.
7. ICP Adhesives Polyset®AH-160 shall not be exposed permanently to sunlight.
8. Tiles must be adhered in freshly applied adhesive.Tile must be set within 1 to 2 minutes after ICP Adhesives
Polyset®AH-160 has been dispensed.
9. ICP Adhesives Polyset®AH-160 placement and minimum patty weight shall be in accordance with the
'Placement Details'herein. Each generic tile profile requires the specific placement noted herein.
r
I
NOA No.: 17-0322.03
MAMI•DADE COUNTY
..., � Expiration Date: 05/10/22
Approval Date:04/27/17
Page 4 of 11
4
I
i
I •
I
Table 1: Adhesive Placement For Each Generic Tile Profile
Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram
Area Weight
Eave Course-Flat,Low,High Profiles All Eave Course 17-23 sq.inches 45-65
Flat,Low,High Profiles #1 17-23 sq.inches 45-65
I Flat Profile 42 10-12 sq. inches 30
Low Profile 42 12-14 sq. inches 30
High Profile 42 17-19 sq. inches 30
Flat,Low,High Profiles #3 Two Paddys: 8-9 sq. inches at 12 grams per paddy
head of tile 9-11 sq.inches at
overlap
Two-Piece Barrel(Cap Tile) Two Piece 2 Beads(1 each longitudinal 17 grams per bead
edge)20-25 sq. inches each
bead
Two Piece Barrel(Pan Tile) Two Piece 65-70 sq. inches 34 grams under pan
LABELING:
All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the
manufacturer's name or logo and following statement: "Miami-Dade County Product Control Approved" or the Miami-
Dade County Product Control Seal as shown below.
E Ct3UE+TY
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or applicable building code in order to properly evaluate the installation of this
system.
I
I
MIAMMADE COUNTY V NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 5 of 11
i
i
1�
I
• , 7
ADHESIVE PLACEMENT DETAIL# 1
tgl� Gut P4MYMhWa7 Flat/Low Profile Tile
i�ws e�q►d�ti�
I
vdti�syt 1. Starting at the eave course,apply a minimum 2"
(50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam
paddy onto the underlayment positioned as shown,
under the strengthening rib closest to the overlock
9Q�� of the tile being set.
Ix�ems�pz�na9 �- o
x
2. Continue in same manner.Insure approximately 17
(109.7 cm2)—23 (148.4 cm2)square inch adhesive
b y contact with the underside of the tile.
TO .-
,�, y do
Medium Profile/ Double Pan Tile
'lwh��eW++rredp
1. Starting at the eave course,apply a minimum 2"
(50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam
paddy onto the underlayment positioned as shown
a under the pan portion of the tile closest to the
overlock of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cm2)—23 (148.4 cm2)square inch adhesive
contact with the underside of the tile.
ItohtPirtrs High Profile/Single Pan Tile
yam, ' 1. Starting at the eave course,apply a minimum 2"
(50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam
paddy onto the underlayment positioned as shown
nJ.R. under the pan portion of the tile closest to the
overlock of the tile being set.
2. Continue in same manner.Insure approximately 17
apizanar (109.7 cm)—23 (148.4 cm2)square inch adhesive
contact with the underside of the tile.
110fia ��n.� �avct[ sFme
NOA No.: 17-0322.03
MIAMI•DAD6 C3 Expiration Date: 05/10/22
Approval Date:04/27/17
Page 6 of 11
I
ADHESIVE PLACEMENT DETAIL#2
Po a Flat/Low Profile Tile
gradymo $ 1. Starting at the eave course apply a minimum 2" 50.8
g � PP Y (
mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy
onto the underlayment positioned as shown under the
strengthening rib of the tile closest to the overlock of
& ` the tile being set.Insure approximately 17 109.7 cm2
e� ra1 a —23 (148.4 cm2)square inch adhesive contact with the
I EaNmCmun�
~' underside of the tile.
�
" r., 2. At the second course,apply a minimum 2"(50.8mm)
x 7"(177.8 mm)x 1"(25.4 mm)foam paddy onto the
underlayment positioned as shown under the
strengthening rib closest to the overlock of the the
being set.
3. Continue in same manner.Insure approximately 10"
(64.5 cm2)- 12(77.4 cm2)square inch adhesive
contact with the underside of the tile.
Medium Profile/Double Pan Tile
When mquin;4k
�y�la ,� jrti 1. Starting at the eave course,apply a minimum 2"(50.8
mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy -
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
tile being set.Insure approximately 17(109.7 cm2)—
��'° zrm. 23 (148.4 ce.)square inch adhesive contact with the
~1. underside of the tile.
2. At the second course,apply a minimum 2"(50.8mm)
x 7"(177.8 mm)x 1"(25.4 mm)foam paddy onto the
underlayment positioned as shown under the pan
portion of the tile closest to the overlock of the tile
being set.
3. Continue in same manner.Insure approximately 12"
(77.4 cm2)- 14(90.3 cm2)square inch adhesive
contact with the underside of the tile.
(Instructions continued on next page)
NOA No.:17-0322.03
MIAMI•DAD,COUNTY Expiration Date: 05/10/22
Approval Date:04/27/17
Page 7 of 11
I
_ i
ADHESIVE PLACEMENT DETAIL#2 (CONTINUED)
Nadi �l High Profile/Single Pan Tile
t han eery, lmQ
1. Starting at the eave course,apply a minimum 2"(50.8
6 mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
tile being set.Insure approximately 17(109.7 cm2)—
7 2Eft. 4. 23 (148.4 cm2)square inch adhesive contact with the
underside of the tile.
I �
2. At the second course,apply a minimum 2"(50.8mm)
F"a'R"M 's.� x 7"(177.8 mm)x 1"(25.4 mm)foam paddy onto the
underlayment positioned as shown under the pan
1:0Em.;� 2M. portion of the tile closest to the overlock of the tile
being set.
3. Continue in same manner.Insure approximately 17"
(109.7 cm2)- 19(122.6 cm')square inch adhesive
contact with�the underside of the tile.
NOA No.: 17-0322.03
MIAMI•DAD;COUNTY Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 8 of 11
i
i
i
ADHESIVE PLACEMENT DETAIL#3
���o�¢lasaz�� tbet�e�rlh7es�
(Whenrequi M) 1. On the eave course only,apply a minimum 2" (50.8
samensmryRiana mm)x 10" (254 mm)x 1" (25.4 mm)foam paddy
onto the underlayment positioned as shown,under
the strengthening rib for flat tile or under the pan
portion of the tile for low or high profile tile closest
.' to the overlock of the tile being set.Leave
approximately 4"(101.6 mm)up from the eave
s�gleWdy. ,; . ., edge free of foam to prevent the expanded adhesive
• �" '°�" ' ax 3 . from blocking the weep holes. Insure
2
approximately 17-23 in (109.7-148.4 cm2)of
poi adhesive contact with the underside of the tile
2. Apply a 4" (101.6 mm)x 4" (101.6 mm)x 1" (25.4
mm)foam paddy onto the underlayment just below
FlatJLQWProfQeUe the second course line positioned foam paddy
under the strengthening rib for flat tile, or under the
Nantl=aqh. z0EMeUt pan portion of the tile,closest to the underlock for
;urban requWed}
ve the second course tile to be installed. Insure
approximately 8-9 in2(51.6-58.1 cm)of adhesive
EkatUng PadAytundwflecontact with the underside of the tile.
t
v on.t,pot, (Instructions continued on next page)
:girt.
epa��
tom in.
EaveGosare
1=aveC�rse- �' Ease3a.
Witham PraflIeTlIG
NOA No.:17-0322.03
MIAMI•DADE COUNTY
..., Expiration Date: 05/10/22
Approval Date:04/27/17
fI Page 9 of 11
ADHESNE PLACEMENT DETAIL#3 (CONTINUED)
J
j $�UCI S 85�L- STa0epaddyunderhl'e
twhenreglaBrem 3. Also apply a 2" (50.8 mm)x 4" (101.6 mm)x 3/4"
(19 mm)paddy on top of the eave course tile
ens surface as shown,on top of the strengthening rib
gnat �. �rt�maer for flat the or on top of the pan portion of the tile,
closest to the underlock of the first course of tile.
Install second course of tile.Insure approximately
amn
9(58.1 cm)- 11 (71cm)square inch adhesive
`. contact with the underside of the tile at the overlap
Swe " ' and 7(45.2 cm')-9(58.1 cmZ)square inch
payon - adhesive contact with the underside of the tile at
the head of the tile. Continue in same manner.
course da
ono
ftredusure
70.ht - $CR edge
Hip.p1mille-me
NOA No.: 17-0322.03
CMLAM1-DMADMECO=UNTY Expiration Date: 05/10/22
"'• ' Approval Date: 04/27/17
Page 10 of 11
I
1
J
ADHESIVE PLACEMENT DETAIL
TWO PIECE BARREL
i
Two Piece Barrel(Cap and Pan)Tile
I 1. Starting at the cave course,apply a minimum 2"
:Y}PEace'enQugijaahesiveYoetctiieYe:85'.tq;XOsq,iti.; 3teeRprtdiap tidf4
i mcontact:w?t{ithgpanle; CvVheprequiKed}: (50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam
2)Tt!]*.ei"sups, d*"Pia' aheswe:in: paddy onto the underlayment positioned as
ao:i in:�rom;cutsideedge_o#cgver#ile:
zite�t�a�irfh�iugn,rc.io shown under two adjacent pan tiles. Support cave
25sq in,writattareaA tiles from rocking until adhesive has a chance to
tliideriaymen! cure.
n.2 Continue in same manner bringing two
g g pan
courses up toward the ridge.Insure
approximately 65 (419.4 em2)—70(451.6 cm2)
square inch adhesive contact with the underside
seath;ny of the pan tile.
Eave ciasme
tmoi�raho } 3. Turn covers upside down exposing the underside
weds°fie iezna,>r era . of the tile.Apply a minimum 1"(25.4 mm)x 10"
(254 mm)bead of adhesive directly on the inner
Reirtosr 'tbp.�ttirtionoftfiee�ve:coglsegtsvirrtile.AGtit[iFs�tatiif;<oifrs�of edge of each side of the cover tile.Leave
pap Ole-Eiisure,�aye ersflbf panand�oV.Ortil'es a�tiilshaC.eavgline..
approximately 3/4"(19 mm)to 1"(25.4 mm)
7Wa Piece,0arm.).fttrProftle.- ife from the outside edge of the tile,inward,free of
foam to allow for expansion.
4. Turn cover tile over after foam is applied and
place onto pan file course.Insure a minimum of
20 (129 cm2)-25 (161.3 cm2)square inch
contact area on each side of the cover tile to the
pan tile. Continue in same manner. Trim away
any cured exposed foam adhesive.Pointing of
longitudinal edges of the cover tiles are
considered optional.
5. When additional nailing is required,2"(50.8
mm)x 4"(101.6 mm)milers or the tie wire
system using galvanized,stainless steel,or
copper wire and compatible nails may be used.
END OF THIS ACCEPTANCE
NOA No.: 17-0322.03
MIAMI-DADE COUNTY
Expiration Date: 05/10/22
j Approval Date:04/27/17
Page 11 of 11