HomeMy WebLinkAboutProduct Approval EXTERIOR RESEARCH&DESIGN,I.I.C. Certificate of Authorization#9503 353 CHRISTIAN STREET,UNIT#13 ` �� OXFORD,CT 06478 - PHONE:(203)262-9245 FAX:(203)262-9243 EVALUATION REPORT East Coast Metals,Inc. Evaluation Report E10240.08.08-R4 2301 West 8 Lane " FL5374-R4 Hialeah,FL 33010 Date of Issuance:09/03/2008 Revision 4:03/17/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition(2014)Florida Building Code sections noted herein. DESCRIPTION: East Coast Metals Channel Metals LABELING: Labeling shall be in accordance with the requirements.the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E.if the product changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in ` advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: " Robert J.M.Nieminen,P.E, ; :' The facsimile sea]appearing was authorized by Robert Nleminen, P.E.on 03/17/2015.This does not serve as an electronically signed Florida Registration No.59156,Florida DCA ANE1983 d=ment,signed,sealed hardcoples have been transmitted to the JJ/pb<I t)O}t Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinity)ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither Trinity)ERD nor Robert Nieminen, P.E. are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. I I - TRINITY ERD `$ ROOFING COMPONENT EVALUATION: 1. SCOPE: f Product Category: Roofing Sub-Category: Roofing Accessories that are an Integral Part of the Roofing Systenj f Compliance Statement: East;:oast Metals Channel Metals, as produced by East Coast Metals, h�ve demonstrated compliance with the following sections ofl he Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation RE juirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.3.7 Installation,non-HVHZ FRSA/TRI April 2012(04-12) I 2012 1518.8.1 Installation,HVHZ RAS 118,119&120 1995 1523.6.5.2.2 Static Uplift Resistance TAS 101 1995 1711.2.1 I Static Uplift Resistance SBCCI SSTD 11 1997 I 3. REFERENCES: Entity Examination Reference Date ERD(TST6049) Static Uplift Resistance E42730;08.13 08/23/2013 ERD(TST6049) Static Uplift Resistance ECM-SC6795.12.14-1 02/27/2015 ERD(TST6049) Static Uplift Resistance ECM-SC6795.12.14-2 02/27/2015 Florida TEC(TST7393) TAS 101 S10-628R I 10/27/2010 PRI(TST5878) TAS 101 ECM-001-02-01 09/21/2001 PRI(TST5878) TAS 101 ECM-003-02-01 l 06/13/2008 PRI(TST5878) TAS 101 ECM-004-02-01 06/13/2008 PRI(TST5878) TAS 101 ECM-005-02-01 06/13/2008 PRI(T5T5878) TA5101 ECM-006-02-01 06/13/2008 PRI(TST5878) TAS 101 ECM-007-02-01 06/13/2008 PRI(TST5878) TAS 101 ECM-008-02-01 06/13/2008 Florida Building Code I Attachment Requirements FRSA/TRI April 2012(04-12) 04/2012 Florida Building Code-HVHZ Attachment Requirements RAS 118,119 and 120 1995 East Coast Metals Metal Quality Mill Certifications Various r Architectura6TestinD(GLUA184 ) Quality Control Participation Letter Exp.12/31/2018 PRODUCT DESCRIPTION: 4.1 Hip & Ridge Channe Metal: Pere-formed metal channel designed for use as a ip and ridge base to which roof tiles are bonded in_EBC,Apl"`;roved roof tile adhesive. --------------- Hip&Ridge Channel Aetal is available in 119-3/8-inch (± 3/8-inch)length by 2.! ,3,3.5,4,5,6 or 7-inch(±3/8-inch). heights with 1.5-inch; :1/16-inch)deck-flanges. I i i i i . i Exterior Research and Design,LLC. Evaluation Report E10240.08.08-R4 Certificate of Authoriratlon#9503 FLS374-114 Revision 4:03/17/2015 Page 2of7 i EPO 4.2 Trim Lock Channel Metal: Pre-formed metal channel ,f. designed for use as a hip and ridge base to which roof tiles are bonded in FBC Approved roof tile adhesive. Trim Lock Channel Metal is characterized by its profiled and perforated upper horizontal flange designed to receive and allow for interlock with the overlying tile adhesive. Trim Lock Channel Metal is available in 119-3/8-inch (± _ 3/8") length by 3, 3.5, 4, 5 or 6-inch l±3/8-inch) heights '. with 1.5-inch(±1/16-inch)deck-flanges. ,A Y•� 4 - -5 4.2 Trim Lock Plus Channel Metal:Pre-formed metal channel designed for use as a hip and ridge base to which roof tiles are bonded in FBC Approved roof tile adhesive. Trim Lock Plus Channel Metal is characterized by its profiled and perforated upper horizontal flange designed to receive and allow for interlock with the overlying tile adhesive and its perforated deck flanges, designed for installation atop the roof underlayment via placement in FBC D` Approved roof the adhesive, which flows-through and a.;. interlocks with the underlying adhesive. Trim Lock Plus Channel Metal is available in 119-3/8-inch - (±3/8")length by 3,3.5,4,5 or 6-inch(±3/8-inch)heights with 1.5-inch L 1/16-inch)deck-flanges. 4.4 East Coast Metals Channel Metals are fabricated of the following metals: ➢ Galvanized Steel: Min.0.019±0.002-inch,ASTM A653(G-90),min.33 KSI. ➢ Galvalume Steel: Min.0.019±0.002-inch,ASTM A792,AZ55,min.35 KSI. ➢ Aluminum: Min.0.032+0.002-inch,ASTM B209,3003-1-114,min.21 KSI. ➢ Stainless Steel: Min.0.019±0.002-inch,ASTM A240/A480,T304,min.35 KSI. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityIERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on %Vhich this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. Exterior Research and Design,I.I.C. Evaluation Report E10240.08.08-R4 Certificate of Authorization#9503 FL5374-R4 Revision 4:03/17/201S Page 3 of 7 \J TRINITY I ER® ' 5.2 FOR HVHZ JURISDIC'IONS: ' 5,21 For Hip & Ridge Ch innel Metal or Trim Lock Channel Metal, refer to FBC RAS 118, Drawing 13, Detail 3; RAS 119, Drawing 12, Detail ; or RAS 120, Drawing 15, Detail 3. For Trim Lock Plus Channel Metal, refer to the installation instructions herein. 5,2.2 For HVHZ jurisdictio. s,installations of Hip&Ridge Channel Metal and Trim Lock are prescriptive by RAS 118, 119 and 120,and the data in 'ables 1A and 113 is supplemental to these prescriptive allowances. Installations of Trim,.ocic Plus are limited to projects having a required moment resistance(Mr)or uplift resistance(F,), as determined in ace)rdance with RAS 127,not greater than the following values. Refer to the tile adhi live manufacturer's published installation instructions for adhesive paddy placement details. ➢ "INDEPENDEN " paddy placement means each individual tile is bonded to the Channel Metal in its own, single foam paddy; + le head laps are not bonded. This method is limited to 2-part tile adhesives. Allowable performance d ita below for"INDEPENDENT" paddy placement already has a 2 to 1 margin of safety applied to ultimate perfoi nance. ➢ "INTERDEPEND:NT"paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy, i and a second f lam paddy bonds the tile head lap,or two tiles are bonded to the Channel Metal using a single foam paddy. A lowable performance data below for"INTERDEPENDENT"paddy placement already has a 4 to 1 margin of safet applied to ultimate performance. r .f �y �TABL LA RkRFORMANCETiMIrATIONS o— INDEPENDEN(P2ODY;PLA(iE{Uj6NT* Xi.twr_V Hip/Ridge Metal Adhesive Allowable Performance Tile Moment Based Uplift Based Design Metal Type Type Placement Mf(ft-Ibf) F(Ibf) : Hip&Ridge clay or 3ML 2-Component Foam Channel Metal galvanized _ concrete Roof Tile AdhesiveAH-160 Independent 127 169 Trim Lock galvanized,Galvalume® clay or 31VIT"2-Component Foam Independent 171 159 aluminum or stainless s:el concrete Roof Tile Adhesive AH-160 Trim Lock Plus galvanized,Galvalume®. clay or 131VIII 2-Component Foam Independent 177 165 aluminum or stainless si!el concrete Roof Tile Adhesive AH-160 PERfORMANC-E I.Irk(l(TA�'fONSYtWUHT.,t`fNTERDEPEND�N7'nPADDY R1�10ElV�ENTe - F ,. i xv L '' .�tr �.ir -tJ Fri . N S� � �,... Ft,. t�.§ � :<. fi -. � i; ✓� _F y e. {' •f,f_,_ Hip/Ridge Metal Adhesive Allowable Performance Design Metal Type Tile Type Placement Moment Based Uplift Based _ Mt(ft-Ibf) F'(Ibf) Trim Lock or Trim galvanized,Galvalume®, clay or 3M'"'2-Component Foam Interdependent 95 88 Lock Plus aluminum or stainless st el concrete Roof Tile Adhesive AH-160 galvanized,Galvalume", clay or 3M'm Roof Tile Adhesive Trim Lock stainless steel concrete RTA-1 Interdependent 99 94 Trim Lock aluminum clay or 3M'""Foam Roof Tile Interdependent 90 84 concrete Adhesive RTA-1 Trim Lock Pius galvanized,Galvalume", clay or 31V11"'Foam Roof Tile Interdependent 90 84 aluminum or stainless st( sl concrete Adhesive RTA-1 Trim Lock galvanized,Galvalume®c clay or TILE BOND""Roof Tile Interdependent 123 117 stainless steel concrete Adhesive Trim Lock aluminum clay or TILE BOND'"Roof Tile Interdependent 79 73 concrete Adhesive Trim Lock Plus galvanized,Galvalume®, clay or TILE BOND'""Roof Tile Interdependent 79 73 aluminum or stainless ste !I concrete Adhesive Trim Lock galvanized,Galvalume®o clay or Touch'n Seal StormBond Interdependent 146 139 stainless steel concrete Roof Tile Adhesive Trim Lock Aluminum clay or Touch'n Seal StormBond Interdependent 58 54 concrete Roof Tile Adhesive Trim Lock Plus galvanized,Galvalume", clay or Touch'n Seal StormBond Interdependent 58 54 aluminum or stainless ste I concrete Roof Tile Adhesive Exterior Research and Design,I.I.C. Evaluation Report E10240.08.08-R4 Certificate of Authorization#9503 FL5374-R4 Revision 4:03/17/2015 Page 4 of 7 I_ __I i i Tf ;INITY ERD 5.3 FOR NON-HVHZ JURISDICTIONS: 5.3.1 For Hip&Ridge Channel Metal or Trim Lock Channel Metal, refer to FRSA/TRI April 2012(04-12). For Trim Lock Plus Channel Metal,refer to the installation instructions herein 5.3.2 For non-HVHZ,installations are limited to projects having hip and ridge design pressure requirements,determined in accordance with Table 1A of FRSA/TRI April 2012 (04-12), not greater than the following values. Refer to the tile adhesive manufacturer's published installation instructions for adhesive paddy placement details. ➢ "INDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in its own, single foam paddy;tile head laps are not bonded. This method is limited to 2-part tile adhesives. This method is limited to 2-part tile adhesives. Allowable performance data below for"INDEPENDENT"paddy placement already has a 2 to 1 margin of safety applied to ultimate performance. ➢ "INTERDEPENDENT"paddy placement means each individual the is bonded to the Channel Metal in a foam paddy, and a second foam paddy bonds the tile head lap, or two tiles are bonded to the Channel Metal using a single foam paddy. Allowable performance data below for"INTERDEPENDENT"paddy placement already has a 4 to 1 margin of safety applied to ultimate performance. � " a; �, : �r,�„�� � �e r-� � r ��wr�-. •ate � � '-��r-as ��" ^..� :. � � r , ;k�?_= x� �'� � � TABLE 2�A PERfx ORI111A'NC,E I:IMRATIONS��TIOId�FIY,HZr INDEPENDENTsPADDY PLACEMENT � �+,.,, � y-� �. _ Hip/Ridge Metal Adhesive Allowable Uplift Tile Design Metal Type Type Placement (psf) rliip&Ridge clay or 3MTM 2-Component Foam Roof galvanized Independent 169 Channel Metal concrete Tile Adhesive AH-160 P Trim Lock galvanized,Galvalume®,aluminum or clay or 3MTM 2-Component Foam Roof Independent 173 stainless steel concrete Tile Adhesive AH-160 Trim Lock Plus galvanized,Galvalume",aluminum or clay or 31VITM 2-Component Foam Roof Independent 178 stainless steel concrete Tile Adhesive AH-160 �ETABLEZBPER 0 MANCT ITA oNS '' oN H1lHZ"I TER EPENDENr&PADDY�PCEM Eit r" ' � A�G1N-0FSAF r'+� ^`� #' � �'� '' t' x.3�'�i',S�Ug,rm �tr.+,`ti �+,q�`:" . .E�,tlr ..,. ...i'".: .:• .��vaaaX�. .1"�.�,._.sti�# ! ... ?R...,._...�»..�'y--q[READYAAPLIEDJ_,.. ? s '' K,...�.::. ``.ax*s.,5r. }��,,.=.: Hip/Ridge Metal Tile Adhesive Allowable Uplift Design Metal Type Type Placement (psf) Trim Lock or Trim galvanized,Galvalume",aluminum or clay or 31VITM 2-Component Foam Roof Lock Plus stainless steel concrete Tile Adhesive AH-160 Interdependent 98 Trim Lock galvanized,Galvalume®or stainless clay or 3MTM Foam Roof Tile Adhesive Interdependent 110 steel concrete RTA-1 Trim Lock aluminum clay or 31VITM Foam Roof Tile Adhesive Interdependent 93 concrete RTA-1 Trim Lock Plus galvanized,Galvalume®,aluminum or clay or 31VITM'Foam Roof Tile Adhesive Interdependent 93 stainless steel concrete RTA-1 Trim Lock galvanized,Galvalume®or stainless clay or TILE BOND-Roof Tile Adhesive Interdependent 152 steel concrete Trim Lock aluminum clay or TILE BOND"Roof Tile Adhesive Interdependent 82 concrete Trim Lock Plus galvanized,Galvalume®,aluminum or clay or TILE BOND-Roof Tile Adhesive Interdependent 82 stainless steel concrete Trim Lock galvanized,Galvalume®or stainless clay or Touch'n Seal StormBond Roof Interdependent 148 steel concrete Tile Adhesive Trim Lock Aluminum clay or Touch'n Seal StormBond Roof Interdependent 61 concrete Tile Adhesive Trim Lock Plus galvanized,Galvalume",aluminum or clay or Touch'n Seal StormBond Roof Interdependent 61 stainless steel concrete Tile Adhesive Exterior Research and Design,LLC. Evaluation Report E10240.08.08-R4 Certificate of Authorization rY9503 FL5374-R4 Revision 4:03/17/2015 Page 5 of 7 I I i I f 1 '\JTRINITYIERD 6. INSTALLATION: n i 6.1 The roof deck shall I e minimum 15/32-inch plywood (non-HVHZ)or minimum 19/32-inch plywood(HVHZ)attached in accordance with FBC Chapter 23 to the satisfaction of the AHJ. 6.2 Hip&Ridge Channe Metal and Trim Lock Channel Metal shall be installed using min. 11 ga.x 1X-inch long x 3/8-inch head diameter galvl nized annular ring shank nails spaced 6-inch o.c. along both deck:flanges. Fasteners shall be positioned%-inch fn m the outside edge of each deck-flange,set in a bed plastic roof cement. For FBC HVHZ,refer to FBC RAS 118,Drawin;13,Detail 3;RAS 119,Drawing 12,Detail 3;or RAS 120,Drawing 15,Detail 3. 6.3 Trim Lock Plus Chanr al Metal shall be installed atop the Approved roof underlayment in continuous 2-inch wide ribbons of tile adhesive centi red beneath each 1.5-inch wide deck flange. Place the Trim Lock Plus Channel Metal into the wet adhesive and allow it.to set-up prior to installation of roof tiles. 1 View of Polyset AI.1161 Placement for Trim Lock Plus Channel Metal Installation 6.3.1 It is critical that the b,and between the Trim Lock Plus Channel Metal,the tile adhesive and the underlayment is not disturbed prior to or di ring;placement of the ridge tiles. 6.3.2 Approved underlayme its are the codified'30/90' system or other FBC Approved roof underlayments listing approved use of the subject tile Jhesive. I 1 Exterior Research and Design,I.I.C. Evaluation Report E10240.08.08-R4 Certificate ofAuthodzation#9903 FL 5374-114 Revision 4:03/171201517J2015 Page 6 of 7 i I Tf1( IIY ERD 6.4 Tile shall be installed atop the Channel Metal in accordance with the the adhesive manufacturer's Approved,published jinstallation instructions,subject to the limitations outlined in Section 5 herein. The exposed edges shall be packed and pointed with Approved mortar or weather blocking adhesive in accordance with FRSA/TRI April 2012 (04-12) or RAS 118,RAS 119,RAS 120 requirements. Hip/Ridge Tile Tile Adhesive ti -.. Trim Lock Plus 'fir:: L.�r� _ '�•,Z^?�'s <• Mortar or Weather Block '� e• Adhesive r 3' \`' '•�+'•k-K:. z _ }, ,.'..ir tit �.�. }'� {'' �_ '+' x, Tile Adhesive View of Trim Lock Plus Channel Metal Installation after Weather Blocked 6.4.1 Channel Metal shall be free of dust,debris,oils or other bond-breaking substance prior to placement of adhesive. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: a Contact the named CIA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 CIA requirements. 9. QUALITY ASSURANCE ENTITY: Architectural Testing,Inc. —QUA1844;(717)764-7700 -END OF EVALUATION REPORT- Exterior Research and Design,I.I.C. Evaluation Report E10240.08.08-R4 Certificate of Authorization#9503 FL5374-R4 Revision 4:03/17/201S t Page 7 of 7 i - i EXTERIOR RESEARCH&DESIGN,LLC. ?` Certificate of Authorization#9503 � TRINITY J ERD 353 CHRISTIAN STREET, UNIT#13 i OXFORD,CT 06478 (203)262-9245 EVALUATION REPORT Polyglass USA,Inc. Evaluation Report P12060.02.09-R22 150 Lyon Drive FL5259-1126 Fernley, NV 98408 Date of Issuance:02/24/2009 (570)384-1230 Revision 22:03/13/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: Polyglass Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report ri lative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 14. repared by: '�,,,�;�;;,«,,,,,r % t= The facsimile seal appearing was authorized by Robert Nieminen, �'• ; P.E.on 03/13/2017. This does not serve as an electronically •;O�.,p�.. W.Robert J.M.Nieminen,P.E. ofi� _c��c:r�: signed document. Signed,sealed hardcopies have been a S''... ...k�.� Florida Registration No.59166,Florida DCA ANE1983 `'.=!�d�;ONE�«�+ transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. t i TRINITY ERD ROOFING COMPONENT EVALUATION: r 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the 5`11 Edition (2014) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. Z. STANDARDS: Section Property Standard Year 1504.3.1 Wind Uplift FM 4474 2004 1504.3.1 Wind Uplift UL 1897 2004 1504.6 Accelerated Weathering ASTM G154 2006 1504.6 Accelerated Weathering ASTM G155 2005 1507.2.3,1507.3.3,1507.5.3,1507.7.3, Physical Properties ASTM D226 2006 1507.8.3,1507.9.3 1507.2.4,1507.2.9.2,1507.5.3,1507.7.3 Physical Properties ASTM D1970 2009 1507.11.2 Physical Properties ASTM D6164 2005 1507.11.2 Physical Properties ASTM D6222 2008 1507.3.3 Installation Practice FRSA/TRI April 2012 2012 1523.6.5.2.1 Physical Properties TAS 103 1995 3. REFERENCES: gntiiY Examination Reference Date FM Approvals(TST 1867) Wind Uplift 3004091 01/12/2000 PRI(TST 5878) Physical Properties PRIO1111 04/08/2002 PRI(TST 5878) Physical Properties PUSA-005-02-01 01/31/2002 PRI(TST 5878) Physical Properties PUSA-013-02-01 12/23/2002 PRI(TST 5878) Physical Properties PUSA-013-02-02 12/23/2002 PRI(TST 5878) Physical Properties PUSA-013-02-03 12/23/2002 PRI(TST 5878) Physical Properties PUSA-018-02-01 07/14/2003 PRI(TST 5878) Physical Properties PUSA-028-02-01 07/13/2005 PRI(TST 5878) Physical Properties PUSA-033-02-01 01/12/2006 PRI(TST 5878) Physical Properties PUSA-035-02-01 09/29/2006 PRI(TST 5878) Physical Properties PUSA-055-02-02 12/10/2007 PRI(TST 5878) Physical Properties PUSA-061-02-02 01/28/2008 PRI(TST 5878) Physical Properties PUSA-076-02-01 02/22/2008 PRI(TST 5878) Physical Properties PUSA-083-02-01 04/14/2008 PRI(TST 5878) Physical Properties PUSA-088-02-01 07/29/2009 MTI(TST 2508) Physical Properties 1X20H7A 04/01/2008 MTI(TST 2508) Physical Properties RX14E8A 01/29/2009 ERD(TST 6049) Physical Properties 11752.09.99-1 02/08/2000 ERD(TST 6049) Wind Uplift 11757.08.01-1 08/13/2001 ERD(TST 6049) Wind Uplift 11776.06.02 01/16/2003 ERD(TST 6049) Physical Properties 02200.07.03 07/14/2003 ERD(TST 6049) Wind Uplift P1740.01.07 01/04/2007 ERD(TST 6049) Physical Properties P5110.04.07-1 04/11/2007 ERD(TST 6049) Wind Uplift P9260.03.08 03/21/2008 ERD(TST 6049) Physical Properties P13450.08.09 08/13/2009 ERD(TST 6049) Wind Uplift P30540.11.09-R1 11/30/2009 ERD(TST 6049) Physical Properties P11030.11.09-1 11/30/2009 ERD(TST 6049) Wind Uplift P11030.11.09-2 11/30/2009 ERD(TST 6049) Physical Properties P11030.11.09-3 11/30/2009 ERD(TST 6049) Physical Properties P33360.06.10 06/25/2010 ERD(TST 6049) Physical Properties P33370.03.11 03/02/2011 Exterior Research and Design,U.C. Evaluation Report 1312060.02.09-1122 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL5259-1126 Polyglass USA,Inc. Revision 22:03/13/2017 Page 2 of 14 I !!!TRINITY ERD I Enti Examination Reference Date ERD(TST 6049) Physical Properties P33370.04.11 04/26/2011 ERD(TST 6049) Physical Properties P37300.10.11 10/19/2011 ERD(TST 6049) Physical Properties P40390.08.12-1 08/06/2012 ERD(TST 6049) Physical Properties P40390.08.12-2 08/07/2012 ERD(TST 6049) Physical Properties C41420.09.12-3 09/11/2012 ERD(TST 6049) Wind Uplift P39680.03.13 03/04/2013 ERD(TST 6049) Physical Properties P45370.04.13 04/26/2013 ERD(TST 6049) Wind Uplift P1738.02.07-R2 04/29/2013 ERD(TST 6049) Wind Uplift 11757.04.01-1-R1 04/30/2013 ERD(TST 6049) Wind Uplift P41630.08.13 08/06/2013 ERD(TST 6049) Wind Uplift P11751.05.03-R1 11/26/2013 ERD(TST 6049) Wind Uplift P11781.11.03-R1 11/26/2013 ERD(TST 6049) Physical Properties P45270.05.14 05/12/2014 ERD(TST 6049) Physical Properties 6020.07.14-1 09/08/2014 ERD(TST 6049) Physical Properties 6020.09.14-2 09 08 2014 ERD(TST 6049) Physical Properties 6020.09.14-3 09/09/2014 ERD(TST 6049) Physical Properties 6020.09.14-4 09/08/2014 ERD(TST 6049) Physical Properties 6020.09.14-5 09/08/2014 ERD(TST 6049) Physical Properties 6020.09.14-6 09/08/2014 ERD(TST 6049) Physical Properties P46520.10.14 10/03/2014 ERD(TST 6049) Physical Properties P44360.10.14 10/07/2014 ERD(TST 6049) Physical Properties P43290.10.14 10/17/2014 ERD(TST 6049) Physical Properties PLYG-SC7550.03.15 03/24/2015 ERD(TST 6049) Physical Properties P40390.04.15 04/03/2015 ERD(TST 6049) Physical Properties PLYG-SC8080.05.15-1 05/20/2015 ERD(TST 6049) Wind Uplift PLYG-SC8905.05.16-1 05/17/2016 ERD(TST 6049) Physical Properties PLYG-SC8080.07.16 07/16/2016 ERD(TST 6049) Wind Uplift PLYG-SC12025.10.16 10/12/2016 ERD(TST 6049) Physical Properties PLYG-SC11900.03.17 03/10/2017 ICC-ES(EVL 2396) IBC Compliance ESR-1697 11/01/2014 Miami-Dade(CER 1592) HVHZ Compliance NOA 14-0717.08 01/22/2015 Polyglass USA Manufacturing Affidavit Products Current 02/18/2009 Polyglass USA P/L Affidavit Mule-Hide Cross Ltg 03/01/2008 Polyglass USA Materials Affidavit Polystick SA Compound 08/18/2011 UL,LLC.(QUA9625) Quality Control Service Confirmation Exp.04/24/2018 4. PRODUCT DESCRIPTION: 41 Mechanically Fastened Underlayments . _. .. ..., 4.1.1 Elastobase is a fiberglass reinforced,SBS modified bitumen base sheet. 4.1.2 Elastobase P is a polyester-reinforced,SBS modified bitumen base sheet. 4.1.3 Polyglass G2 Base is a fiberglass-reinforced,asphaltic base sheet. 4.1.4 Polyglass APP Base is a fiberglass-reinforced,APP modified bitumen base sheet. 4 2 Self Adher�eg Und"layments; _._., 4.2.1 Polystick MTS is a nominal 60-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,surfaced with polyolefinic film surface;meets TAS 103. 4.2.2 Polystick MTS PLUS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced with poly-film surface;meets TAS 103. 4.2.3 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,with an aggregate surface;meets ASTM D1970. Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R22 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION F1.5259-1126 Polyglass USA,Inc. Revision 22:03/13/2017 Page 3 of 14 I C CI \j TRIIeIITY ERD 4.2.4 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,with a polyester fabric surface; meets ASTM D1970 and TAS 103. 4.2.5 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester reinforced,with a granular surface;meets ASTM D1970 and TAS 103. 4.2.6 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/m2 polyester fabric surface;meets ASTM D1970 and TAS 103. 4.2.7 Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet (FR) are polyester reinforced,APP modified bitumen cap sheets;meet ASTM D6222. 4.2.8 Polystick Dual Prolm is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass reinforced,with a polyester fabric surface;meets ASTM D1970. 4.2.9 Polystick Tile Pro' is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass reinforced,with a polyester fabric surface;meets ASTM D1970 and TAS 103. 4.2.10 Polystick MU-X is a nominal 54-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass reinforced,with a polypropylene film surface; meets AC188 and physical requirements of ASTM D1970 (See Section S.8). 4 3 �_ Mechanically Fastened and/or Boned Underlayments r .a 4.3.1 Elastoflex G TU is a polyester reinforced, modified bitumen tile underla ment composed of an sand-surfaced SBS modified bitumen back-side and granule-surfaced APP modified bitumen top-side. Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or Hot Asphalt applied "Cap Sheet" in the `Two Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened or adhered tile roof systems. 4.3.2 Elastoflex S6 G and Elastoflex S6 G FR are polyester reinforced,SBS modified bitumen cap sheets;meet ASTM D6164. Elastoflex S6 G and Elastoflex S6 G FR are for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M)in the"Single Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened tile roof systems. Elastoflex S6 G is for use as an alternate to Hot Asphalt applied "Cap Sheet" in the`Two Ply System"from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Elastoflex S6 G FR is for use as an alternate to Hot Asphalt applied "Cap Sheet" in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened the roof systems. 4.3.3 Polyflex G and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets; meet ASTM D6222. Polyflex G is for use as an alternate to Heat Applied "Cap Sheet" in the`Two Ply System"from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered the roof systems. Polyflex G FR is for use as an alternate to Heat Applied "Cap Sheet" in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. S. LIMITATIONS: SA This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. Exterior Research and Design,I.I.C. Evaluation Report P12060.02.09-1122 Certificate ojAuthorization#9503 FBC NON-HVHZ EVALUATION FL5259-R26 Polyglass USA,Inc. Revision 22:03/13/2017 Page 4 of 14 I \j TRINITY 1 ERD 5.5 Allowable Roof Covers: ` t TABLE 1 X ROOF COVER OPTIONS l ' Underlayment Asphalt Shingles Nail-On Tile Foam-On Tile Metal wood Shakes Slate &Shingles Elastobase Yes Yes Yes Yes Yes Yes (Base Sheet in 2-ply system) (Base Sheet in 2-ply system) Elastobase P Yes Yes Yes Yes Yes Yes (Base Sheet in 2-ply system) (Base Sheet In 2-ply system) Polyglass G2 Base No Yes Yes No No No (Base Sheet in 2-ply system) (Base Sheet in 2-ply system) Yes Yes Polyglass APP Base No (Base Sheet in 2-ply system) (Base Sheet n 2-ply system) No No NO Polystick MTS Yes Yes No Yes Yes Yes Polystick MTS PLUS Yes Yes No Yes Yes Yes Polystick IR-Xe Yes No No No Yes Yes Polystick TU P Yes Yes Yes (See 5.5.1) No Yes Yes PolystickTU Plus Yes 7 e5 - Yes (See 5.5.1) Yes Yes Yes wR*stic-k1&U_Max2=mwNo Yes Yes (See 5.5.1) Yes No No Polystick Dual Pro Yes Yes No Yes Yes Yes Polystick Tile Pro Yes Yes Yes (See 5.5.1) Yes Yes Yes Polystick MU-X Yes No No Yes Yes Yes Elastoflex S6 G Yes Yes Yes (See 5.5.1) No Yes Yes Elastoflex S6 G FR Yes Yes No No Yes Yes Elastoflex G TU Yes Yes Yes (See 5.5.1) No Yes Yes Polyflex G Yes Yes Yes (See 5.5.1) No Yes Yes Polyflex G FR I Yes Yes No No Yes Yes Polyflex SAP or SAP FR Yes Yes Yes (See 5.5.1) No Yes Yes Mule-Hide SA-APP Cap Sheet Yes Yes Yes (See 5.5.1) No Yes Yes or SA-APP Cap Sheet(FR) 5.5.1 "Foam-On Tile"is limited to use of the following Approved tile adhesives/underlayment combinations. ;x TABiE lA iAL101NABLE TILE'ADHESIVE/UNDERLAYMENT COMBI(VATlONS Adhesive Florida Product Underlayments Approval Convenience Products'Touch'n FL14506 PolystickTU Plus,PolystickTU Max Seal Storm Bond Roof Tile Adhesive Dow TileBond' FL717 Polystick TU P,Polystick TU Plus,Polyflex SAP or Tile Pro PolystickTU P,PolystickTU Plus,PolystickTU Max,Polystick Tile Pro, ICP Adhesives Polyset°AH-160 FL6332 Elastoflex G TU,Elastoflex S6 G,Polyflex G,Polyflex SAP,Polyflex SA Cap FR,Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR) Polystick TU P,Polystick TU Plus,Polystick TU Max,Polystick Tile Pro, ICP Adhesives Polyset®RTA-1 FL6276 Elastoflex G TU,Elastoflex S6 G,Polyflex G,Polyflex SAP,Polyflex SA Cap FR,Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR) Polyglass PolyLok Roof Tile FL17855 Polystick TU Plus or Polystick TU Max Adhesive 1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R22 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL5259-R26 Polyglass USA,Inc. Revision 22:03/13/2017 Page 5 of 14 C_)o TRINITY I ERD 5.6 Allowable Substrates: 5.6.1 Direct-Bond to Deck: Polystick(all variations),Dual Pro,Tile Pro, Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR)self-adhered to: ➢ New untreated plywood;ASTM D41 primed new untreated plywood; Existing plywood;ASTM D41 primed existing plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIP System" Panels (designed and installed to meet wind loads for project). Note: Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes. Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ ASTM D41 primed structural concrete. Polyflex G or Polyflex G FR torch-applied to: ➢ ASTM D41 primed structural concrete. 5.6.2 Bond-to-Insulation: Polystick(all variations), Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR)self-adhered to: ➢ ASTM C1289, Type 11, Class 1 polyisocya nu rate or Type V polyisocyanurate-composite insulation; Dens Deck DuraGuard;Dens Deck Prime;or SECUROCK Gypsum-Fiber Roof Board. Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board. Polyflex G or Polyflex G FR torch-applied to: ➢ ASTM D41 primed structural concrete;Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on tile systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FBC Section 1504.3.1. 5.6.3 Bond to Mechanically Attached Base Laver: Polystick (all variations), Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR) Dual Pro or Tile Pro self-adhered to: ➢ ASTM D226,Type I or II felt;Elastobase;Elastobase P or Mule-Hide Nail Base. Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ ASTM D226,Type I or II felt;Elastobase;Elastobase P,Mule-Hide Nail Base or Polyglass G2 Base. Polyflex G or Polyflex G FR torch-applied to: ➢ Elastobase;Elastobase P,Mule-Hide Nail Base,Polyglass G2 Base or Polyglass APP Base. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam-on tile systems, base layer shall be attached per minimum requirements of FRSA/TRI April 2012(04-12),Appendix A,Table 1,or as listed in Section 5.6.4 herein, or as tested in accordance with FBC Section 1504.3.1. 5.6.4 Wind Resistance for Underlavment Svstems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems, where the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012(04-12)and are used in foam-on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012(04- 12),Appendix A,Table 1A or FBC 1609 for determination of design wind loads. Exterior Research and Design,U.C. Evaluation Report P12060.02.09-R22 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL5259-1126 Polyglass USA,Inc. Revision 22:03/13/2017 Page 6 of 14 F)o TRINITY ERD 5.6.4.1 Maximum Design Pressure=-90 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: None Base Ply: (Optional)Polystick MTS PLUS,self-adhered Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. 5.6.4.2 Maximum Design Pressure=-97.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply: (Optional)Polystick MTS PLUS,self-adhered Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x 1%"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c. 5.6.4.3 Maximum Design Pressure=-105 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: WB-3000 Base Ply: (Optional)Polystick MTS PLUS,self-adhered Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x 1Y."ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c. 5.6.4.4 Maximum Design Pressure=-135 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional)PG100 or ASTM D41 Joints: Min.4-inch wide strips of Elastoflex SA-V over all plywood joints. Base Ply: (Optional)Polystick MTS PLUS,self-adhered Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. 5.6.4.5 Maximum Design Pressure=-315 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply: (Optional)Polystick MTS PLUS,self-adhered Underlayment: Polystick TU P, Polystick TU Plus,Polystick TU Max,Tile Pro, Polyflex SAP, Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. 5.6.4.6 Maximum Design Pressure=-622.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. 5.6.4.7 Maximum Design Pressure=-30.0 psf*: Deck: Min.15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS PLUS,self-adhered Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. 5.6.4.8 Maximum Design Pressure=-37.5 psf*: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS PLUS,self-adhered Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R22 Certificate ofAathori:ation#9503 FBC NON-HVHZ EVALUATION FL5259-R26 Polyglass USA,Inc. Revision 22:03/13/2017 Page 7 of 14 I f TRINITY ERD 5.6.4.9 Maximum Design Pressure=-37.5 psf*: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One(1)or two(2)layers ASTM D226,Type II felt Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt. I 5.6.4.10 Maximum Design Pressure=-45 psf*: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One(1)layer ASTM D226,Type II felt Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch o.c.at the 2-inch wide side laps and 4-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS PLUS,self-adhered Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elastoflex G TU,applied in full mopping of hot asphalt. 5.6.4.11 Maximum Design Pressure.=-45 psf*: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Two(2)layers ASTM D226,Type II felt Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 9-inch c.c.at the 2-inch wide side laps and 9-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS PLUS,self-adhered Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elastoflex G TU or Elastoflex 56 G,applied in full mopping of hot asphalt. 5.6.4.12 Maximum Design Pressure=-45 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch o.c.at the 2-inch wide side laps and 18-inch o.c.at two(2)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. 5.6.4.13 Maximum Design Pressure=-52.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. 5.6.4.14 Maximum Design Pressure=-52.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS PLUS,self-adhered Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. 5.6.4.15 Maximum Design Pressure=-52.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. Exterior Research and Design,U.C. Evaluation Report P12060.02.09-R22 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL5259-R26 Polyglass USA,Inc. Revision 22:03/13/2017 Page 8 of 14 I TRINITY I ERD 5.6.4.16 Maximum Design Pressure=-60 psf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. 5.6.4.17 Maximum Design Pressure=-60 psf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: CMG#12 Standard Roofgrip with CMG Flat Bottom Metal Plates Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. 5.6.4.18 Maximum Design Pressure=-67.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass APP Base(requires use of torch-applied underlayment) Fasteners: 12 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at four(4)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch-applied or Polyflex G, torch- applied. 5.6.4.19 Maximum Design Pressure=-75 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass APP Base(requires use of torch-applied underlayment) Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with CMG 3"Galvalume Steel Plates,CMG Roofgrip#14 with CMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: 10-inch o.c.at the 4-inch wide side laps and 10-inch o.c.at three(3)equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch-applied or Polyflex G, torch- applied. 5.6.4.20 Maximum Design Pressure=-90 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. 5.6.4.21 Maximum Design Pressure=-90 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: OMG#12 Standard Roofgrip or CMG#14 Heavy Duty with OMG 3"Round Metal Plates or CMG Flat Bottom Metal Plates Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. 5.6.4.22 Maximum Design Pressure=-90 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface) Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt. Exterior Research and Design,U.C. Evaluation Report P12060.02.09-R22 Certificate of Authorization#9503 FBC NON-HVH2 EVALUATION FL5259-1126 Polyglass USA,Inc. Revision 22:03/13/2017 Page 9 of 14 • i ` TRINITY ERD 5.6.4.23 Maximum Design Pressure=-90 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. j Base Sheet: Polyglass G2 Base or Polyglass APP Base(requires use of torch-applied underlayment) Fasteners: Dekfast#14 with Dekfast Hex plates, CMG#14 HD with OMG 3"Galvalume Steel Plates,OMG Roofgrip#14 with OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap j Fasteners Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or torch-applied or Polyflex G, torch- applied. 5.6.4.24 Maximum Design Pressure=-97.5 psf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch o.c.at the 4-inch wide side laps and 4-inch o.c.at four(4)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS PLUS,self-adhered Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. 5.6.4.25 Maximum Design Pressure=-105 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. 5.6.4.26 Maximum Design Pressure=-112.5 psf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer at all tin-caps Base Ply: Polystick MTS PLUS,self-adhered Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. 5.6.4.27 Maximum Design Pressure=-120 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. 5.6.4.28 Maximum Design Pressure=-120 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface) Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt. 5.6.4.29 All other direct-deck, adhered Polyglass underlayment systems beneath foam-on tile systems carry a Maximum Design Pressure of-45 psf. Exterior Research and Design,U.C. Evaluation Report P12060.02.09-R22 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL5259-1126 Polyglass USA,Inc. Revision 22:03/13/2017 Page 10 of 14 I i TRINITY ERD 5.6.4.30 For mechanically attached Base Sheet,the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012(04-12),Appendix A,Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case,Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDi, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016)for Zone 2/3 enhancements. 5.7 Exposure Limitations: Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30-days after installation. Polystick IR-Xe or Polystick MU-X shall not be left exposed for longer than 90-days after installation. Polystick MTS, MTS PLUS,TU P,TU Plus,TU Max, Dual Pro,Tile Pro or Elastoflex G TU shall not be left exposed for longer than 180-days after installation. Polyflex SAP or SAP FR, or Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure limitation, unless the prepared roof covering is to be adhesive-set tile, in which case the maximum exposure is 30 days. Elastoflex S6 G or Elastoflex S6 G FR or Polyflex G or Polyflex G FR does not have an exposure limitation, unless the prepared roof covering is to be adhesive-set tile (Elastoflex S6 G or Polyflex G only), in which case the maximum exposure is 180 days. 5.8 Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226 roofing felt in a dry condition,tested at standard laboratory conditions. Agreement between purchaser and seller,as set forth in Section 5.3,Note 1 of ASTM D1970-09,should be established as to slip resistance. 6. INSTALLATION: 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate(if applicable). 41 Elastobase;Elastobase P or aVlule H Ide Nail Base _. 6.3.1 Shall be installed in compliance with the codified requirements for ASTM D226,Type II underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.3.2 Non-Tile Applications: Reference is made to the current edition of the NRCA Steep-slope Roofing Manual and ARMA recommendations for installing shingle underlayments and flashings Elastobase, Elastobase P or Mule-Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), Dual Pro or Tile Pro, self-adhered, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR,torch applied. 6.3.3 Tile Applications: Reference is made to FRSA/TRI April 2012(04-12)Installation Manual and Table 1 herein,using the instructions noted above as a guideline. Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R22 Certificate ofAuthorizotion#9503 FBC NON-HVHZ EVALUATION FL52S9-R26 Polyglass USA,Inc. Revision 22:03/13/2017 ! Page 11 of 14 i I TRINITY I ERD Its= MaxPyflex SAP,Poly O lde SA APP`Cap Street or Mule Hlde SA APP Cap Sheet(fR) _ 6.4.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. Note: Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226 roofing felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller,as set forth in Section 5.3,Note 1 of ASTM D1970-09,should be established as to slip resistance. 6.4.2 Direct-to-Deck with Mechanically Fastened Roof Covers: All self-adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FIR and Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR)should be back-nailed in selvage edge seam in accordance with Polyglass/Mule- Hide Back Nailing Guide. Nails shall be corrosion resistant,11 gauge ring-shank type with a minimum 1-inch diameter metal disk or Simplex-type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back-nailed using the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of membrane. The head lap membrane is to cover the area being back-nailed. All seal-lap seams (selvage laps) must be firmly rolled with a minimum 28 lb. hand ' 4 roller to ensure full contact and adhesion. For Dual Pro and Tile Pro, align the edge of the top sheet to the end of the glue pattern + (the sheet will overlap the fabric). - Yt z. View of Ovelap Seam of Dual Pro and Tile Pro All over-fabric and over-granule end-laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap. Polystick TU Plus,Dual Pro and Tile Pro may not be used in any exposed application such as crickets,exposed valleys, or exposed roof to wall details Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or Polyglass PG500 Modified Cement to the area in need of repair, followed by a minimum 6 x 6 inch patch of the Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be installed in a water shedding manner. All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a minimum of 40-lb weighted-roller or,on steep slopes, use of a stiff broom with approximately 40-lbs of load applied for the field membrane. Hand rollers are acceptable for rolling of patches,laps(min.28 lb roller)or small areas of the roof that are not accessible to a large roller or broom. 6.4.3 Tile Applications(not allowed for Polystick IR Xe or Polystick MU X): Reference is made to FRSA/TRI April 2012(04-12)Installation Manual and Table 1 herein,using the instructions noted above as a guideline. For mechanically fastened tile roofing over 2-ply system,consisting of Base Sheet and self-adhering top sheet(s), Base Sheet fastening shall be not less than FRSA/TRI April 2012(04-12),Table 1. For adhesive-set tile applications,refer to Section 5.6.4 herein. For nail-on tile systems over Polystick MTS,battens are required for loading/staging of the tile. For nail-on tile systems over Polystick MTS PLUS: ➢ Battens are required for loading/staging of lugged tile regardless of slope. ➢ Battens are required for loading/staging of flat tile at slopes in excess of 5:12. Exterior Research and Design,U.C. Evaluation Report P12060.02.09-R22 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL5259-1126 Polyglass USA,Inc. Revision 22:03/13/2017 Page 12 of 14 I TRINITY I ERD 6.4.4 Two(2)Ply UnderlaVment Systems: Polystick MTS or MTS PLUS followed by Polystick MTS,MTS PLUS,TU P,TU Plus,TU Max,Tile Pro,MU-X or Polyflex SAP is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the top-layer material. This is not a requirement,but is allowable if a 2-ply underlayment system is desired. Polystick MTS PLUS followed by Polystick TU P,TU Plus,TU Max,Tile Pro or Polyflex SAP is allowable for use under foam-on tile systems. Limits of use are those associated with the top-layer material. This is not a requirement,but is allowable if a 2-ply underlayment system is desired. 6 5 Elastoflex G TU,ElastofldkU G or„Elastoflex 56 GFR r ti 6.5.1 Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications: ✓ Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the"Single Ply System"from FRSA/TRI April 2012(04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet" in the"Two Ply System"from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. ✓ Elastoflex S6 G is for use as an alternate to"Mineral Surface Roll Roofing"(ASTM D6380,Class M)in the"Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet" in the"Two Ply System"from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. ✓ Elastoflex S6 G FR is for use as an alternate to"Mineral Surface Roll Roofing"(ASTM D6380,Class M)in the"Single Ply System"from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied"Cap Sheet" in the"Two Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened tile roof systems. 6.5.2 For hot-asphalt-applications,Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR shall be fully asphalt-applied to the substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end-laps minimum 6-inch wide, off-set minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. 6 6 Polyflex G or Polyflex G FR ° , 4 6.6.1. Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications: ✓ Polyflex G.is for use as an alternate to the Heat Applied"Cap Sheet" in the"Two Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened or adhered tile roof systems(Base Sheet Limited per 5.6.3). ✓ Polyflex G FR is for use as an alternate to the Heat Applied applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012(04-12)beneath mechanically fastened tile roof systems(Base Sheet Limited per 5.6.3). 6.6.2 Polyflex G or Polyflex G FR shall be fully torch-applied to the substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end-laps minimum 6-inch wide, off-set minimum 3 feet from course to course. Side and end laps shall be fully heat-welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge. Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R22 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL5259-RZ6 Polyglass USA,Inc. Revision 22:03/13/2017 Page 13 of 14 i TRINITY I ERD 6.7 Tile Staging: 6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Polyglass published requirements for the staging. 6.7.2 Battens and/or Counter-battens,as required by the tile manufacturer and FRSA/TRI April 2012(04-12) must be used on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or nail- boards,to prevent tile sliding and/or damage to the underlayment during the loading process. 6.7.3 For nail-on tile systems over Polystick MTS,battens are required for loading/staging of the tile. 6.7.4 For nail-on the systems over Polystick MTS PLUS: ➢ Battens are required for loading/staging of lugged tile regardless of slope. ➢ Battens are required for loading/staging of flat tile at slopes in excess of 5:12. 6.7.5 The minimum cure time after installation of self-adhering membranes and before loading of roofing tiles is forty-eight (48)hours. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C.Rule 61G20-3 Q4 requirements. 9. QUALITY ASSURANCE ENTITY: UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com -END OF EVALUATION REPORT- Exterior Research and Design,I.I.C. Evaluation Report P12060.02.09-R22 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL5259-R26 Polyglass USA,Inc. Revision 22:03/13/2017 j Page 14 of 14 i I EXTERIOR RESEARCH&DESIGN,LLC. Certificate of Authorization#9503 TR�N�N I ERD 353 CHRISTIAN STREET,UNIT#13 QOOXFORD,CT 06478478 THESE PLANO'AN ►all PROPOSEW RI( PHONE:(203)262-9245 ARE SU13J CT T O AN'!(()j CtCTJ0NS - FAX:(203)262-9243 EVALUATION REPORT REQUIRED FOY HELD THAT -`' I11"�w i .. Entegra Roof Tile,$W BE NECESSARY IN CAVIRR dEvaluat�n Report E39310.11.11-2-R4 r.NTEGRA 1289 NE 9 Avenuu&nY ! H t'bI L f;QpF - `r FL7804-R9 R O O F T I L E Okeechobee, FL 34972 """"'Date of Issuance:11/02/2011 Revision 4:04/18/2016 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code(non- HVHZ)sections noted herein. DESCRIPTION: Entegra Concrete Roof Tiles(non-HVHZ jurisdictions) LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. CONCE'�'FD rAS�'E RS l�R'P���f•1lifllif°ENTS Prepared by: gtstttlr;!zr,,' ARE 1�� fF�rd�'IILI OF W Robert J.M.Nieminen,P.E. ',0�••p :•. ;�.T,+?�,' The facsimile seal appearing was authorized by Robert Nleminen, oS•;C ,,,. P.E.on 04/18/2016.This does not serve as an electronically signed Florida Registration No.59166,Florida DCA ANE1983 ;'�°SON�Lti,`< document.Signed,sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report, previous ver ions thereof,is/was �16)�() used for permitting or design guidance unless retained specifically for that purpose. ( ST. LUCIE COUNT BUILDING DIVISIO V G F_VIEE%Fd2� FOR O®9fI� A ��, El REVIEWED BY " v L DATE F-- PLANS AND PEPWI i MUST 61; KrIP 'ON dOD OR NO INSPCC'PION Wli,lL aR MADE i i TRINITY I ERD ROOFING SYSTEM EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Roofing Tiles Compliance Statement: Entegra Concrete Roof Tiles, as produced by Entegra Roof Tile, LLC, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.3.5,R905.3.5 Physical Properties ASTM C1492 2003 1507.3.7,R905.3.7 Attachment Requirements FRSA/TRI April 2012(04-12) 2012 1711.2.1 Overturning Moment SSTD 11 1997 3. REFERENCES: Entity Examination Reference Date ATL(TST3782) Physical Properties RT0615.01-11 06/28/2011 ATL(TST3782) Physical Properties RT0615.02-11 06/28/2011 ATL(TST3782) Physical Properties RT0615.03-11 06/28/2011 ATL(TST3782) Physical Properties RT0615.04-11 06/28/2011 ATL(TST3782) Physical Properties RT0615.05-11 06/28/2011 ATL(TST3782) Physical Properties RT0316.01-12 05/31/2012 ATL(TST 3782) Physical Properties RT1103.01-15 11/07/2015 ATL(TST 3782) Physical Properties RT1103.02-15 11/07/2015 ATL(TST 3782) Physical Properties RT1103.03-15 11/07/2015 ATL(TST 3782) Physical Properties RT1103.04-15 11/07/2015 ATL(TST 3782) Physical Properties RT1103.05-15 11/07/2015 PRI(TST5878) Physical Properties ESI-001-02-01 11/06/2006 PRI(TST5878) Physical Properties ESI-002-02-01 11/06/2006 PRI(TST5878) Physical Properties ESI-003-02-01 11/06/2006 PRI(TST5878) Physical Properties ESI-004-02-01 11/06/2006 PRI(TST5878) Physical Properties ESI-005-02-01 12/12/2006 PRI(TST5878) Physical Properties HRT-023-02-01 11/19/2007 PRI(TST5878) Physical Properties HRT-026-02-01 01/08/2008 Tile Roof Institute SSTD 11 Membership Confirmation Current PRI(QUA9110) Quality Assurance Inspection Report 11/04/2015 Exterior Research and Design,U.C. Evaluation Report E39330.11.11-2-R4 Certificate of Authorization 89503 FL7804-119 Revision 4:04/18/2016 Page 2 of 6 I i i I TRINITY I ERD 4. PRODUCT DESCRIPTION: 4.1 BERMUDA FLAT PLANTATION FLAT nd HORIZON FLAT are ASTM C1492,Type III(low-profile)concrete roof tiles. r 16'- _ 1-1/T4' T 10, i Y i i ------16'-mil z• 10, / Y Bermuda Flat < > Plantation Flat 17-1/4" 13" / Horizon Flat Exterior Research and Design,U.C. Evaluation Report E39310.11.11-2-R4 Certificate of Authorization#9503 F1.7804-119 Revision 4:04/18/2016 Page 3 of 6 i ��TRINIWIERD 4.2 BELLA HIGH"S",ESTATE"S"and HACIENDA are ASTM D1492,Type II(medium-profile)concrete roof tiles. I 16 21" 13-4" Bella High"S" Nail Holes • • 16l l3 Estate"S" 0 0 i �3 Hacienda Exterior Research and Design,LLC. Evaluation Report E39310.11.11-2-R4 Certificate of Authorization#9503 FL7804-R9 Revision 4:04/18/2016 Page 4 of 6 i TRINITY I ERD 4.3 GALENA SPANISH"S"and REGAL are ASTM C1492,Type I (high-profile)concrete roof tiles. I I I 17 101, Galena Spanish"S" a e 13 1/a" Regal S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire classification is not part of this evaluation; refer to FBC Section 1505, Exception 2 or current Approved Roofing Materials Directory for fire rating of this product. 5.4 Underlayment shall be that approved by Entegra Roof Tile, which holds Florida Local or Statewide Product Approval for use with tile roofing systems. The underlayment Product Approval shall specify allowable method(s) of tile installation (mechanical attachment, mortar-set and/or adhesive-set) for use with the specific underlayment. For mortar-set or adhesive-set tile roofing applications, the underlayment Product Approval shall specify attachment methods for the underlayment system to resist wind uplift design loads in accordance with Table 1A of FRSA/TRI April 2012(04-12). 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C.Rule 61G20-3. Exterior Research and Design,I.I.C. Evaluation Report E39330.11.11-2-R4 Certificate of Authorization#9503 F1.7804-119 Revision 4:04/18/2016 Page 5 of 6 I ' I r 1 I ��TRINrryfERD 6. INSTALLATION: 6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar-set or adhesive-set. Installation shall comply with manufacturer's current published instructions, but not less than the requirements of FBC Section 1507.3,the FRSA/TRI Florida High Wind Concrete and Clay Tile Installation Manual, 5`h Edition and, for mortar-set or adhesive-set applications,the mortar or adhesive manufacturer's Product Approval. 6. Attachment: Mechanically Attached Tile: Wind load resistance shall be in accordance with Table 3 of FRSA/TRI April 2012 (04-12) to resist the Uplift Moment determined in Table 2A or 213 of FRSA/TRI April 2012(04-12). Mortar-Set or Adhesive-Set Tile: Wind load resistance shall be in accordance with FBC Section 1609.5.3 in conjunction with the mortar or adhesive manufacturer's Product Approval. Hip and Ridge Tile: Tile shall be installed in accordance with FRSA/TRI April 2012(04-12). For hip and ridge tile installations atop hip and ridge metal, refer to the hip and ridge metal manufacturer's Product Approval (e.g., FL5374) or test report in accordance with SSTD 11 for allowable loads to resist those determined in accordance with Table 1A of FRSA/TRI April 2012(04-12). 7. LABELING: 7.1 Each unit shall bear the imprint and/or identifiable marking of the manufacturer's name or logo. Tile lots shall be labeled in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. Rule 61G20-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: PRI Construction Materials Technologies,LLC.—QUA9110;(813)621-5777 -END OF EVALUATION REPORT- Exterior Research and Design,I.I.C. Evaluation Report E39310.11.11-2-R4 Certificate of Authorization#9503 FL7804-R9 Revision 4:04/18/2016 Page 6 of 6 I i • 3 : , MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.sov/economy ICP Adhesivesand Sealants,Inc. O �I T LI 12505 NW 44'Street �—✓� ` (!./ V Coral Springs,FL.33065 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ On areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: ICP Adhesives Polyset®AH-160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. •TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA 16-0315.01 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera Ful 1k.,­5!I LY NOA No.: 17-0322.03 MIAMI•DAb;COUNTY Expiration Date: 05/10/22 Approval Date:04/27/17 Page 1 of 11 I ' i ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves ICP Adhesives Polyset®AH-160 as manufactured by ICP Adhesives and Sealants,Inc.as described in this Notice of Acceptance.For the locations where the design pressure requirements,as determined by applicable building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat,low, and high profile roof tile systems using ICP Adhesives Polyset®AH-160. PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications ICP Adhesives N/A TAS 101 Two component polyurethane foam adhesive Polyset®AH-160 ICP Adhesives*Foam N/A Dispensing Equipment Nip Dispenser RTF1000 ICP Adhesives ProPack® N/A Dispensing Equipment 30& 100 PRODUCTS MANUFACTURED BY OTHERS: Any Miami-Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of ICP Adhesives Polyset®AH-160 roof tile adhesive. MANUFACTURING LOCATION: ^ 1. Tomball,TX. PHYSICAL PROPERTIES: Prove Provertv Test Results Density ASTM D 1622 1.6 lbs./ft.3 Compressive Strength ASTM D 1621 18 PSI Parallel to rise 12 PSI Perpendicular to rise Tensile Strength ASTM D 1623 • 28 PSI Parallel to rise Water Absorption ASTM D 2127 0.08 Lbs./Ff Moisture Vapor Transmission ASTM E 96 3.1 Perm/Inch Dimensional Stability ASTM D 2126 +0.07%Volume Change @-40°F.,2 weeks +6.0%Volume Change @1580F., 100%Humidity,2 weeks Closed Cell Content ASTM D 2856 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 17-0322.03 MIAMI•DAD;COUNTY Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 2 of 11 I i I i II , i EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Center for Applied Engineering #94-060 TAS 101 04/08/94 257818-IPA TAS 101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 ' 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 Miles Laboratories ° NB-589-631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories,Inc. 9637-92 ASTM E 108 04/30/93 Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94 01-6739-062b[l] ASTM E 84 01/16/95 Trinity Engineering 7050.02.96-1 TAS 114 03/14/96 P36700.04.12 ASTM D 1623 04/18/12 P39740.02.12 TAS 101 02/21/12 TAS 123 Celotex Corp. Testing Services 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 520109-3 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109-2-1 LIMITATIONS: 1. Fire classification is not part of this acceptance.Refer to the Prepared Roof Tile Assembly for fire rating. 2. ICP Adhesives Polyset®AH-160 shall solely be used with flat,low,&high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset®AH-160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. audit in accordance with the Florida Building 5. All products listed herein shall have a quality assuranceg Code and Rule 61 G20-3 of the Florida Administrative Code. . NOA No.: 17-0322.03 MIAMI•DADE COUNTY Expiration Date: 05/10/22 Approval Date:04/27/17 Page 3 of 11 ° I INSTALLATION: 1. ICP Adhesives Polyset®AH-160 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of ICP Adhesives Polyset®AH-160. 2. ICP Adhesives Polyset®AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP Adhesives Polyset®AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami-Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. ICP Adhesives Polyset®AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS 120,and ICP Adhesives and Sealants,Inc.'s Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained'Qualified Applicator'approved and licensed by ICP Adhesives and Sealants,Inc. ICP Adhesives and Sealants,Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the ICP Adhesives Foam Dispenser RTF1000 dispensing equipment is required before application of any adhesive. The mix ratio between the"A" component and the"B" component shall be maintained between 1.0-1.15 (A): 1.0(B). 6. ICP Adhesives Polyset®AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF1000 or ICP Adhesives ProPack®30& 100 dispensing equipment only. 7. ICP Adhesives Polyset®AH-160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive.Tile must be set within 1 to 2 minutes after ICP Adhesives Polyset®AH-160 has been dispensed. 9. ICP Adhesives Polyset®AH-160 placement and minimum patty weight shall be in accordance with the 'Placement Details'herein. Each generic tile profile requires the specific placement noted herein. r I NOA No.: 17-0322.03 MAMI•DADE COUNTY ..., � Expiration Date: 05/10/22 Approval Date:04/27/17 Page 4 of 11 4 I i I • I Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram Area Weight Eave Course-Flat,Low,High Profiles All Eave Course 17-23 sq.inches 45-65 Flat,Low,High Profiles #1 17-23 sq.inches 45-65 I Flat Profile 42 10-12 sq. inches 30 Low Profile 42 12-14 sq. inches 30 High Profile 42 17-19 sq. inches 30 Flat,Low,High Profiles #3 Two Paddys: 8-9 sq. inches at 12 grams per paddy head of tile 9-11 sq.inches at overlap Two-Piece Barrel(Cap Tile) Two Piece 2 Beads(1 each longitudinal 17 grams per bead edge)20-25 sq. inches each bead Two Piece Barrel(Pan Tile) Two Piece 65-70 sq. inches 34 grams under pan LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami-Dade County Product Control Approved" or the Miami- Dade County Product Control Seal as shown below. E Ct3UE+TY BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. I I MIAMMADE COUNTY V NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 5 of 11 i i 1� I • , 7 ADHESIVE PLACEMENT DETAIL# 1 tgl� Gut P4MYMhWa7 Flat/Low Profile Tile i�ws e�q►d�ti� I vdti�syt 1. Starting at the eave course,apply a minimum 2" (50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock 9Q�� of the tile being set. Ix�ems�pz�na9 �- o x 2. Continue in same manner.Insure approximately 17 (109.7 cm2)—23 (148.4 cm2)square inch adhesive b y contact with the underside of the tile. TO .- ,�, y do Medium Profile/ Double Pan Tile 'lwh��eW++rredp 1. Starting at the eave course,apply a minimum 2" (50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown a under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2)—23 (148.4 cm2)square inch adhesive contact with the underside of the tile. ItohtPirtrs High Profile/Single Pan Tile yam, ' 1. Starting at the eave course,apply a minimum 2" (50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown nJ.R. under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner.Insure approximately 17 apizanar (109.7 cm)—23 (148.4 cm2)square inch adhesive contact with the underside of the tile. 110fia ��n.� �avct[ sFme NOA No.: 17-0322.03 MIAMI•DAD6 C3 Expiration Date: 05/10/22 Approval Date:04/27/17 Page 6 of 11 I ADHESIVE PLACEMENT DETAIL#2 Po a Flat/Low Profile Tile gradymo $ 1. Starting at the eave course apply a minimum 2" 50.8 g � PP Y ( mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the overlock of & ` the tile being set.Insure approximately 17 109.7 cm2 e� ra1 a —23 (148.4 cm2)square inch adhesive contact with the I EaNmCmun� ~' underside of the tile. � " r., 2. At the second course,apply a minimum 2"(50.8mm) x 7"(177.8 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown under the strengthening rib closest to the overlock of the the being set. 3. Continue in same manner.Insure approximately 10" (64.5 cm2)- 12(77.4 cm2)square inch adhesive contact with the underside of the tile. Medium Profile/Double Pan Tile When mquin;4k �y�la ,� jrti 1. Starting at the eave course,apply a minimum 2"(50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy - onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set.Insure approximately 17(109.7 cm2)— ��'° zrm. 23 (148.4 ce.)square inch adhesive contact with the ~1. underside of the tile. 2. At the second course,apply a minimum 2"(50.8mm) x 7"(177.8 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner.Insure approximately 12" (77.4 cm2)- 14(90.3 cm2)square inch adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.:17-0322.03 MIAMI•DAD,COUNTY Expiration Date: 05/10/22 Approval Date:04/27/17 Page 7 of 11 I _ i ADHESIVE PLACEMENT DETAIL#2 (CONTINUED) Nadi �l High Profile/Single Pan Tile t han eery, lmQ 1. Starting at the eave course,apply a minimum 2"(50.8 6 mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set.Insure approximately 17(109.7 cm2)— 7 2Eft. 4. 23 (148.4 cm2)square inch adhesive contact with the underside of the tile. I � 2. At the second course,apply a minimum 2"(50.8mm) F"a'R"M 's.� x 7"(177.8 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown under the pan 1:0Em.;� 2M. portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner.Insure approximately 17" (109.7 cm2)- 19(122.6 cm')square inch adhesive contact with�the underside of the tile. NOA No.: 17-0322.03 MIAMI•DAD;COUNTY Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 8 of 11 i i i ADHESIVE PLACEMENT DETAIL#3 ���o�¢lasaz�� tbet�e�rlh7es� (Whenrequi M) 1. On the eave course only,apply a minimum 2" (50.8 samensmryRiana mm)x 10" (254 mm)x 1" (25.4 mm)foam paddy onto the underlayment positioned as shown,under the strengthening rib for flat tile or under the pan portion of the tile for low or high profile tile closest .' to the overlock of the tile being set.Leave approximately 4"(101.6 mm)up from the eave s�gleWdy. ,; . ., edge free of foam to prevent the expanded adhesive • �" '°�" ' ax 3 . from blocking the weep holes. Insure 2 approximately 17-23 in (109.7-148.4 cm2)of poi adhesive contact with the underside of the tile 2. Apply a 4" (101.6 mm)x 4" (101.6 mm)x 1" (25.4 mm)foam paddy onto the underlayment just below FlatJLQWProfQeUe the second course line positioned foam paddy under the strengthening rib for flat tile, or under the Nantl=aqh. z0EMeUt pan portion of the tile,closest to the underlock for ;urban requWed} ve the second course tile to be installed. Insure approximately 8-9 in2(51.6-58.1 cm)of adhesive EkatUng PadAytundwflecontact with the underside of the tile. t v on.t,pot, (Instructions continued on next page) :girt. epa�� tom in. EaveGosare 1=aveC�rse- �' Ease3a. Witham PraflIeTlIG NOA No.:17-0322.03 MIAMI•DADE COUNTY ..., Expiration Date: 05/10/22 Approval Date:04/27/17 fI Page 9 of 11 ADHESNE PLACEMENT DETAIL#3 (CONTINUED) J j $�UCI S 85�L- STa0epaddyunderhl'e twhenreglaBrem 3. Also apply a 2" (50.8 mm)x 4" (101.6 mm)x 3/4" (19 mm)paddy on top of the eave course tile ens surface as shown,on top of the strengthening rib gnat �. �rt�maer for flat the or on top of the pan portion of the tile, closest to the underlock of the first course of tile. Install second course of tile.Insure approximately amn 9(58.1 cm)- 11 (71cm)square inch adhesive `. contact with the underside of the tile at the overlap Swe " ' and 7(45.2 cm')-9(58.1 cmZ)square inch payon - adhesive contact with the underside of the tile at the head of the tile. Continue in same manner. course da ono ftredusure 70.ht - $CR edge Hip.p1mille-me NOA No.: 17-0322.03 CMLAM1-DMADMECO=UNTY Expiration Date: 05/10/22 "'• ' Approval Date: 04/27/17 Page 10 of 11 I 1 J ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL i Two Piece Barrel(Cap and Pan)Tile I 1. Starting at the cave course,apply a minimum 2" :Y}PEace'enQugijaahesiveYoetctiieYe:85'.tq;XOsq,iti.; 3teeRprtdiap tidf4 i mcontact:w?t{ithgpanle; CvVheprequiKed}: (50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam 2)Tt!]*.ei"sups, d*"Pia' aheswe:in: paddy onto the underlayment positioned as ao:i in:�rom;cutsideedge_o#cgver#ile: zite�t�a�irfh�iugn,rc.io shown under two adjacent pan tiles. Support cave 25sq in,writattareaA tiles from rocking until adhesive has a chance to tliideriaymen! cure. n.2 Continue in same manner bringing two g g pan courses up toward the ridge.Insure approximately 65 (419.4 em2)—70(451.6 cm2) square inch adhesive contact with the underside seath;ny of the pan tile. Eave ciasme tmoi�raho } 3. Turn covers upside down exposing the underside weds°fie iezna,>r era . of the tile.Apply a minimum 1"(25.4 mm)x 10" (254 mm)bead of adhesive directly on the inner Reirtosr 'tbp.�ttirtionoftfiee�ve:coglsegtsvirrtile.AGtit[iFs�tatiif;<oifrs�of edge of each side of the cover tile.Leave pap Ole-Eiisure,�aye ersflbf panand�oV.Ortil'es a�tiilshaC.eavgline.. approximately 3/4"(19 mm)to 1"(25.4 mm) 7Wa Piece,0arm.).fttrProftle.- ife from the outside edge of the tile,inward,free of foam to allow for expansion. 4. Turn cover tile over after foam is applied and place onto pan file course.Insure a minimum of 20 (129 cm2)-25 (161.3 cm2)square inch contact area on each side of the cover tile to the pan tile. Continue in same manner. Trim away any cured exposed foam adhesive.Pointing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required,2"(50.8 mm)x 4"(101.6 mm)milers or the tie wire system using galvanized,stainless steel,or copper wire and compatible nails may be used. END OF THIS ACCEPTANCE NOA No.: 17-0322.03 MIAMI-DADE COUNTY Expiration Date: 05/10/22 j Approval Date:04/27/17 Page 11 of 11 i