Loading...
HomeMy WebLinkAboutCertification for Design Load Compliance (2) Planning&Development Services Department N- M Building&Code Regulations Division 2300 Virginia Avenue,Fort Pierce, FL 34982—(772)462-1553 Certification for Design Load Compliance �. Project Name: i ' -32E5 Project Address: 12c',,rcell. .-r 3"2 Z 00 �. `} Permit#: 17f7 1, 06011 Occupancy Type: �Construction Type: , INSTRUCTIONS FOR USE: a This certification must be completed,signed,and sealed by the design professional of record. • Submit(2)copies for residential,(3)copies for commercial with all permit applications involving the following: c New Residences(single or multi-family) c Residential Addition c Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official.Contact the#above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE; Florida Code Fifth Edition with 20 Supplements using ASCE 7-10 2. Structure Designed as(check one): _Enclosed "Pa ially Enclosed _Open 3. Risk Category: _I --X/II `III IV Exposure Category: ✓B C _D 4. Design Wind Velocity mph _ASD _LRFD End Zone Width: 5. Mean Roof Height ft Roof Pitch: :12 Parapet: ft 6. Components&Cladding Design Pressures Used:(PSF,based on 10sgft @ 15'MRH,clearly label on all plan openings): Zone 1:'V3C1 Zone 2: 14,10 Zone 3: o" Zone 4: 52•109 Zone 5: 91v3I Garage: 7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Live:�alcony: --- PSF Dock: PSF Deck: — PSF Stairs: _PSF Fence: PSF Railings: PSF S. Were Shear Walls Considered For Structure? Yes Not Applicable Explain Why Not: aY 9. Is A Continuous Load Path Provided? tl/_Yes Not Applicable Explain Why Not: s F 10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? VIYesJ DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that,to the best of my knowledge and belief,the attached plans&specifications have been designed to comply with the,.applicable structural portions of the building codes currently adopted and enforced by St. Lucie County l also cert�yjat structural elements depicted on these plans provide adequate resistance to the design forces '� ;k ;>de 4� r; J��..a �T' • �37r / v�dr rI� C._.V C7 Print Name Cert#&Co.Cert Auth. 4`t *$gna ure Da e'and;seN t) / 30 c(c 3,3046-0 Company Name Address Revised b7� 5�2014 FILE COPY t r . . i `a sj 1���.