Certification for Design Load Compliance
�. Project Name: i ' -32E5
Project Address: 12c',,rcell. .-r 3"2 Z 00 �.
`} Permit#: 17f7 1, 06011 Occupancy Type: �Construction Type: ,
INSTRUCTIONS FOR USE:
a This certification must be completed,signed,and sealed by the design professional of record.
• Submit(2)copies for residential,(3)copies for commercial with all permit applications involving the following:
c New Residences(single or multi-family)
c Residential Addition
c Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official.Contact the#above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE; Florida Code Fifth Edition with 20 Supplements using ASCE 7-10
2. Structure Designed as(check one): _Enclosed "Pa ially Enclosed _Open
3. Risk Category: _I --X/II `III IV Exposure Category: ✓B C _D
4. Design Wind Velocity mph _ASD _LRFD End Zone Width:
5. Mean Roof Height ft Roof Pitch: :12 Parapet: ft
6. Components&Cladding Design Pressures Used:(PSF,based on 10sgft @ 15'MRH,clearly label on all plan openings):
Zone 1:'V3C1 Zone 2: 14,10 Zone 3: o" Zone 4: 52•109 Zone 5: 91v3I Garage:
7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Live:�alcony: --- PSF
Dock: PSF Deck: — PSF Stairs: _PSF Fence: PSF Railings: PSF
S. Were Shear Walls Considered For Structure? Yes Not Applicable Explain Why Not:
aY 9. Is A Continuous Load Path Provided? tl/_Yes Not Applicable Explain Why Not:
s
F
10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? VIYesJ
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that,to the best of my knowledge and belief,the attached plans&specifications have been designed to
comply with the,.applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County l also cert�yjat structural elements depicted on these plans provide adequate resistance to the design
forces
'� ;k ;>de 4� r; J��..a �T' • �37r / v�dr rI� C._.V C7
Print Name Cert#&Co.Cert Auth.
4`t
*$gna ure Da e'and;seN t) / 30 c(c 3,3046-0
Company Name Address