Loading...
HomeMy WebLinkAboutApproved PlansIF THERE ARE NO MARKUPS ON LAYOUT, THEN TRUSSES WILL BE BUILT AS DESIGNED AND CT WILL NOT BE BACK —CHARGED FOR ANY ITEMS FOUND AFTER THE FACT OF THE RETURNED LAYOUT ALL DIMENSIONS AND CONDITIONS THAT EFFECT WD. TRUSSES MUST BE VERIFIED BY BUILDER AND/OR ARCHITECT BEFORE ANY PRODUCTION OF WD. TRUSSES _O O N VERIFY ALL DIMENSIONS, WALL HGT.s, COL. HGT.s & LOCATION GIRDER LOCATIONS, CLG HGT.s, COFFER CLG. LOCATIONS END DETAILS, PITCH, FASCIA, O.H. & CANT SOME DOWN FRAMING REQ. BY BLDR. DROP CLG., CEILING CHANGE & COFFER CLG. AREAS 5/12 101511 5/12 9' 8 1 /2" 37' 411 20' 1011 101511 9' 8 1 /2" A3 37' 4'1 O O N 21 01' APPROVED TRUSS ANCHOR BY BUILDER PLUMB CUT OVERHANG HEEL HEIGHT = 6 3/6" BOTTOM = 2x4 MIN. TOP = 2x4 MIN. 12 5 l7 4/12 VAULT n TRUSS END DETAIL jlC �I � c� I CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD AREWORK SUB,IECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE 0-00", ALL MANUFACTURES LABLES SHOWING U FACTORS AND SHOO COMPLIANCE WRH FSC ENERGY CODE MUST REMAIN ON ALL DOORS AND WINDOWS UNTIL INSPECTIONS ARE APPROVEF) APPROVED TRUSS ANCHOR BY BUILDER SQUARE CUT OVERHANG HEEL HEIGHT = 8" BOTTOM = 2x4 MIN. TOP = 2x4 MIN. 12 5� 8" 12 TRUSS END DETAIL 1104 - 0605 ST. LUCIE COUNTY' T LkNCE n REVIENED FOR CO. L+aJL VIEWED Bi' U�TDATE OR NO LNSPECTION WILL BE 4ADE -NffT NJUST BE MT ON JOB `I p'TICIi i1,CEN ti% ,r�r,�I.,r;NraLo Iv�1T' c C c. I ' 6 F rJ T4: T4E DESIGN rdSTH THE li:i r t r R IIt!.L YTS. CON.. TO �E CON- 1 , G8 �I F OR 1fIFORMATION tJLD A.Ni3 r .I rll. r NAT hNS EOAIa'' FL VJ WE FAf FiIC/ (IJrI PF •:USES OR TO d EONidIOULS Of Cnit,T,rr)CTION; AND FG'i "CCRDINATION OF Tk1E VI OF ALL TRACE">. I`N.VVLDDARCHITECTUR NC. J/113Y_ — Wind Load Type. LOADS ROOF FLOOR ASCE 7-10 MWFRS Design Wind SIDES& 170 mph TCLL 30 40 Building Type: Enclosed TCDL 15 20 Category importance Factor: II 1.00 BCDL 10 5 Duration Factor: Roof 1.25 / Floor 1.00 BCLL 0 0 Building Exposure: "C" TOTAL 55 65 Truss bottom chord analyzed with 10psf non -concurrent live load 30 psf concurrent We load on trusses designed with storage space. TRUSS HANGER INFORMATION Check TRUSS ENGINEERING for gravity and uplift values. If the value exceeds the capacity of a hanger shown below, then it is the responsibility of the builder to provide a suitable connection. All 2-ply hanger values are based on a 2-ply supporting girder. HANGER GRAVITY FASTENER CONN. ROOF FLOOR UPLIFT GIRDER TRUSS A THD26 2x6 3060 26" 2266 18.16d 12-10d 1 112" B THD2B 2zB 4485 4115 2330 28-16d 16-1ad 1 112" C THD26-2 2x6 3355 2770 2340 18-16d 12-10d D THDH26-2 2x6 5245 4375 2340 20-16d 8-16d E THDH26.3 2.6 5245 4375 2340 20-16d 8-16d F THD26.2 2x8 5005 4310 2695 28-16d III G THDH28-2 2.8 8025 7360 3330 36-16d 1046d H THDH28-3 2x8 7835 7595 4370 36-16d 12-1 lad I THD46 2x8 3175 2540 2285 18-16d 12-10d J HJC26 2X6 3490 2135 16-16d 5.10d K SKHH46LJR 2x6 2100 1680 1345 12-06d 6.16d L SKHH26UR 2x6 1890 1510 2190 18-16d 12-10dx142 M SKH1-126L-tiR-2 2.6 2100 1680 895 12-16d 4-16dx2-112 N O GTWS2T 2x8 10900 8720 8435 22-WS3 16-WS3 P GTWS3T 2z8 12470 11100 12490 28-WS3 24-WS3 Q GTWS4T 2x8 12470 11100 12490 28-WS3 24-WS3 R MSTAM24MTWM20 Connection - 1545 5 114" Tapcon 91 OR EQUAL by bldr. s T RT16A OR EQUAL Connection 1380 8-10tl 8.10tlzt-112" by bldr. x 2-RT16A OR Connection _ 2760 11 1840 ixb112" EQUAL by bldr. Y Z CONNECTOR BY BLDR **IMPORTANT INFORMATION" ALL REACTIONS, UPLIFTS, ETC. ARE THE RESPONSIBILITY OF THE ENGINEER OF RECORD, PER LOCAL CODE. REFER TO THE STRUCTURAL FRAMING FOR INFORMATION. CT IS NOT AND WILL NOT TAKE ANY RESPONSIBILITY FOR ANY TYPE OF THIS INFORMATION. THIS INFORMATION IS THE SOLE RESPONSIBILITY OF THE ENGINEER OF RECORD. BEARING HEIGHT DISCLAIMER: IT IS THE SOLE RESPONSIBILITY OF THE ARCHITECT OR PROJECT ENGINEER REGARDING BEAM ELEVATIONS AND BREAK LOCATIONS FOR CHANGES IN BEAM HEIGHTS. CT BEAM HEIGHT SCHEDULE IS A GUIDELINE ONLY. REFER TO ARCHITECTUAL AND STRUCTURAL DRAWINGS FOR THIS INFORMATION. CT IS NOT AND WILL NOT BE RESPONSIBLE FOR THIS INFORMATION. FIELD BRACING is not the responsibility of the truss fabricator, truss designer, or plate .Pers persons erecting trusses are cautioned to seek professional advice regarding manufacturer.rao g p 9 g temporary and erection bracing which is always required to prevent toppling and tlomition during erection, and permanent bracing which may be required in specific applicationss. Trusses shallbe erected and fastened in a straight and plumb position. Where no direct top chord sheathing is applied, trusses must be braced at 24" on center maximum. Where no direct botom chord sheathing is applied, trusses must be braced per local code, during erection to prevent damage or personal Trusses Refer to truss tl with extreme care on a ct p g injury. Refer to truss engineering far connection and bracing requirements. These calculations are supplied in order for the ENGINEER OF RECORD to adequately provide for connection and integration of the roof assembly to the supporting structure. Designers of supporting connections are SOLELY responsible for the integrity of their product.Trusses remain our property until paid for in full. Truss layouts and engineering may not be reproduced in part or in full under any circumstances. SHOP DRAWING APPROVAL THIS PLACEMENT PLAN MUST BE APPROVED PRIOR TO COMMENCING TRUSS ENGINEERING OR FABRICATTON. THE BUILDER MUST VERIFY THE COORDINATION OF ALL THE INFORMATION IN THIS PLAN WITH THE ARCHITECTURAL OR STRUCTURAL DRAWINGS. ANY VARIATIONS BETWEEN THE FINAL PLACEMENT PLAN AND THE ARCHITECTURAL OR STRUCTURAL PLAN IS THE SOLE RESPONIBILITY OF THE CUSTOMER, AND ANY EXPENSES INVOLVED IN CHANGES AFTER TRUSS FABRICATION IS THE RESPONSIBILITY OF THE CUSTOM AND NOT CUSTOM TRUSS LLC. Approved By Date. NOTE: Horizontal and Vertical Truss reactions and uplift calculations are provided by CUSTOM TRUSS LLC., for the JOB ENGINEER OF RECORD to accurately provide support for the ROOF TRUSS SYSTEM and for proper connection of the ROOF TRUSS SYSTEM to the supporting structure. State of Florida Registered Engineer � � 2j '! „ji1�"I CARL G. FORBES, PE FL.Reg.Nos 20699 555 W. POMPANO PKWY. r-�a so POMPANO BEACH, FL. 33069- (954) 682-6651 Date { Revisions: -494 CUSTOM TRUSS 1890 W. ATLANTIC AVE. DELRAY BEACH, FL 33444 PH: (954) 786-8800 FAX: (954) 786-8804 SOLTY PLUMBING Job Name: CESPEDES RESIDENCE PAVILLION Job Address: C24 CANAL ROAD Subdivision: Lot: Block: City: S I FORT PIERCE°Fliv Drawn By: e: Date: B GURDA 1/1 4/14/2017 Job Number: #170465 N 103 3" DENOTES PROPOSED o DECK AND o LANDSCAPE N AREAS 43'-3" LOT BOUNDARY - -- - - - - - - - - - - - - --- - - - - -- - ---------- -- - - -- LANDSCAPE AREAS NATIVE VEGETATION 110 POOL PAVILION OIL25.0' NAVD FIN. FL 23'-0" DENOTES PROPOSED DECK AND LANDSCAPE AREAS I N t4l 10" 38'-6" 40 -3" UL LJ..I ,Kt O \(n 1 4" FT POOL SLOPE (BY OTHERS) POOL DECK �I 02 24.5' NAVD_qF ROUGH FIN. FIL I I 1 4'/FT 1 4" FT vc SLOPE SLOPE ------------------ ------------------------- - - - -- ---- 4cUzzI____T ------- (BY OTHERS) TER FALL \� POOL DECK (BY OTHERS) II „ I 1 4 FT SLOPE SUMMER KITCHEN EN C � I ` R E'EZ EW AY Ij25.0 NA ✓D SIN.- r 7'-0" 1 34'-6" I I 7' 0 I N 24.5' NAVD ROUGH FIN. FL OIL24.0- NAVD ROUGH FIN. FL I i 1 N IN 55'-9" 12' 0" 0 LANDSCAPE AREA OR SOD LANDSCAPE AREA OR SOD NORTH 112 i SITE PLAN I SCALE: 1 /8" = 1'-0" FINNVOLD ARCHITECTURE, ZINC. POOL, POOL DECK & POOL PAVILION 8000 N. FEDERAL HWY. SUITIE 118 BOCA RATON, FL 3 3 4 8 7 COVERED AREA = 778 S.F. P. 561 306 4286 F. 561 9,53 5210 " iE If A A 26002586 SITE PLAN KEY NOTES 101 CONTRACTOR TO COORDINATE LOCATION/CONNECTION OF TELEPHONE, CABLE AND ELECTRICAL SERVICE WITH ST LUCIE COUNTY UTILITIES DEPARTMENT. 102 PAVER DRIVEWAY AND PATHWAYS. REFER TO DETAIL 5/AO.07 103 FUTURE GENERATOR LOCATION, 10'-0" MIN. FROM HOUSE, 10'-0" MIN. FROM ANY INTAKE OPENING. REFER TO 7/AO.07 FOR PAD DETAIL. COORDINATE FOR FUTURE TRANSFER SWITCH WITH ELECTRICAL PANELS PROVIDED 104 TANK -LESS GAS WATER HEATERS 105 500 GAL. UNDERGROUND PROPANE TANK. SIZE & HOLE DIMENSIONS TO BE CONFIRMED WITH GAS COMPANY (PERMIT BY OTHERS) 106 DENOTES NEW CONCRETE PADS. SEE DETAIL 7/AO.07 107 1"0 WATER CONNECTION, 100' MIN. FROM SEPTIC. CONTRACTOR TO COORD. W/UTILITIES DEPT., MEP, & CIVIL DWGS. 108 NEW SEPTIC SYSTEM & DRAIN FIELD LOCATION. CONTRACTOR TO COORDINATE WITH UTILITIES, CIVIL AND MEP DRAWINGS 109 ELECTRICAL METER/ OR SUB PANEL. REFER TO ELECTRICAL DRAWINGS FOR DETAILS. COORD. W FPL. 110 DENOTES NEW UNDERGROUND ELECTRIC. CONTRACTOR TO COORDINATE WITH FPL 111 DENOTES POOL EQUIPMENT. CONTRACTOR TO COORDINATE 112 CRUSHED SHELL ROCK PATHS/PARKING. COORD. W OWNER. 113 PROPOSED LIFT STATION. COORDINATE W CIVIL DRAWINGS 114 PROPOSED WELL LOCATIONS. COORDINATE WITH CIVIL DRAWINGS 115 STUB -OUT FOR FUTURE CABLE INSTALLATION (CONTRACTOR TO COORDINATE LOCATION WITH OWNER) 116 PROVIDE WATER SOFTENER AND FILTERING SYSTEM AS REQUIRED 117 DENOTES COMPOSTE STATION AT STABLES/MANURE PIT 18 ALUM. GATE (STYLE TO SELECTED BY OWNER) 119 4'6" H. ALUM. FENCE (STYLE TO SELECTED BY OWNER) 120 24"x24"x6'0 HI. CONCRETE BLOCK PIERS, SEE DETAIL SHEET AO.07 12"xl2"x5'0 HI. CONC. BLOCK PIERS PLACED MIN. 12" FROM 121 PROPERTY LINE AND FOOTINGS MUST BE WHOLLY ON THE PROPERTY. SEE GATE ELEV. DETAIL SHEET AO.07 4'6"'H (2' MESH) ALUMINUM CHAIN LINK FENCE BY OTHERS, 122 CONTRACTOR TO COORDINATE WITH OWNER. PROVIDE SHRUBS PLANTED AT 24" ON CENTER And MIN. 30" FROM FENCE. SEE LANDSCAPE PLANS. 3 RAIL HORSE BOARD WOOD FENCE BY OTHERS, CONTRACTOR 123 TO COORDINATE WITH OWNER. RAMM HORSE FENCE AND STALLS (800)434.8456 PREFABRICATED WOOD AND ALUMN. PANEL STALLS BY OTHERS, 124 CONTRACTOR TO COORDINATE WITH OWNER. RAMM HORSE FENCE AND STALLS (800)434.8456 RECEIVED AP?: z317 NS AND DETAILS INDICATED OR TED BY THIS DRAWING ARE FOR THE USE ON ONJUNCTION WITH THE SPECIFIED THIS IS THE PROPERTY OF RNNVOLD LURE, INC. AND SHALL NOT BE USED OR -ED WHOLE OR IN PART WITH -OUT ERMISSION OR BE LIABLE FOR THE FULLEST 'OURSE. THE CONTRACTOR SHALL VERIFY VG CONDITIONS AND DIMENSIONS AND EARCHITECT OF ANY DISCREPANCIES THE D(ECUTION OF THE WORK, NEW RESIDENCE OR MR. CESPEDES PARCEL ID 32-24-111-0002-D00-2 C-24 CANAL RD SAINT LUCIE COUNTY 2.27.17 1701 REVISIONS PERMIT SET 4.26.17 CONSULTANTS architect z 0 /U Qz Z z� w �U w w /x �j wce Q O OJ �O �> r z � LL H U co w co = N U� w G 'O 0 O M O z'0 z LET LL (V o� / N c^ Q� °U ce a <C 0 a QLL ao IL 0. x a O O C a ° a oJ 0. h N O C / D UQ FINNVOLD ARCHITECTURE, INC. 8000 N FEDERAL HWY SUITE1 18 BOCA RATON, FL 33487 P 561.953.5200 F 561.953.5210 structural and MEP engineer CARL G. FORBES PE 555 SOUTH POMPANO PARKWAY POMPANO BEACH, FL. 33069 P 954.682.6651 F 954.903.4284 carlforbes@bellsouth. net landscape consultant Grasshoppers Landscape and Deg 10480 W Atlantic Ave Delray Beach, FL 33446 ph: 561 638 2356 Fax: 561 638 9704 Civil en Knight, McGuire & Assoc. Inc. 80 Royal Palm Pointe, suite 401 Vero Beach, FI. 32960 772-569-5505 GENERAL NOTES LOCATION MAP CESPEDES RESIDENCE ST. LUCIE COUNTY. FLORIDA �N FINNVOLD ARCHITECTURE, INC. HATCH AREA DENOTES PROPOSED LOT LOCATION FOR NEW HOME 01 GENERAL REQUIREMENTS 01 04 CLEANING AND WASTE MANAGEMENT 08 OPENINGS 09 06 CEMENTITIOUS COATINGS 0. THE CONTRACTOR SHALL MAINTAIN THE PREMISE CLEAN AND FREE OF 08 01 OPENINGS 0. ALL CEMENTTTIOUS COATINGS TO BE 5/8" THICK MINIMUM, APPLIED IN 23 HEATING, VENTILATION, AND AIR CONDITIONING 01 01 GENERAL INFORMATION ALL TRASH DEBRIS AND SHALL PROTECT ALL ADJACENT WORK FROM A. CONTRACTOR TO VERIFY ALL ROUGH OPENINGS WITH MANUFACTURER'S TWO COATS, AND PAINTED DAMAGE, SOILING, PAINT, OVER SPRAY, ETC. ALL FIXTURES, EQUIPMENT, SPECIFICATIONS PRIOR TO CONSTRUCTION OF SHELL. b. CONTINUOUS EXPANSION JOINTS SHALL BE INSTALLED AT ALL AREAS OF 23 01 REFER TO MECHANICAL DRAWINGS FOR NOTES, REQUIREMENTS AND A ALL WRITTEN DIMENSIONS & NOTES SHALL SUPERSEDE SCALE & GRAPHICS GLAZING, FLOORS, ETC. SHALL BE LEFT CLEAN AN READY FOR DISSIMILAR MATERIALS, MULTIPLE STORY PLATE LINES, OR NEW/EXISTING SPECIFICATIONS OCCUPANCY UPON COMPLETION OF THE PROJECT B. ALL EXTERIOR WINDOWS AND DOORS SHALL APPROVED HURRICANE CONSTRUCTION JOINTS. B_ COORDINATE ALL PHASES OF CONSTRUCTION WITH OWNER 03 CONCRETE WINDOW` &DOORS, OR WILL HAVE AN APPROVED HURRICANE SHUTTER C. PER ASTM C 1063, EXPANSION AND OR CONTRACTION JOINTS SHALL BE 26 ELECTRICAL C. THE ARCHITECT SHALL NOT BE RESPONSIBLE FOR AND WILL NOT HAVE 03 D1 REFER TO STRUCTURAL DRAWINGS FOR NOTES, REQUIREMENTS AND PROTECTION INSTALLED IN WALLS NOT MORE THAN 144 S.F. IN AREA AND NOT MORE THAN 100 S.F. IN ALL HORIZONTAL APPLICATIONS. THE DISTANCE 26 01 REFER TO ELECTRICAL DRAWINGS FOR NOTES, REQUIREMENTS AND CONTROL OR CHARGE OF CONSTRUCTION MEANS, METHODS, TECHNIQUES, SPECIFICATIONS C. WINDOW AND DOOR BUCKS ARE CONSIDERED AS FILLERS AND THE WINDOW BETWEEN JOINTS SHALL NOT EXCEED 18 FT. IN EITHER DIRECTION OR A SPECIFICATIONS SEQUENCES OR PROCEDURES, OR FOR THE SAFETY PRECAUTIONS AND AND/OR DOOR SHALL BE SECURED TO THE STRUCTURE THROUGH THE LENGTH —TO —WIDTH RATION OF 2-1/2 TO 1 PROGRAMS IN CONNECTION WITH THE WORK, AND THE ARCHITECT WILL NOT FOR BUCKS IN ACCORDANCE WITH THE MANUFACTURER'S PRODUCT APPROVAL 26 02 ALL ENERGY STAR APPLIANCES. FINAL SELECTION AND PURCHASE TO BE RESPONSIBLE THE CONTRACTOR'S FAILURE TO CARRY OUT THE WORK 04 MASONRY AND SPECIFICATIONS BE COORDINATED WITH OWNER. IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. THE ARCHITECT SHALL NOT 10 SPECIALTIES BE RESPONSIBLE OR HAVE CONTROL OR CHARGE OVER THE ACTS OR 04 01 REFER TO STRUCTURAL DRAWINGS FOR NOTES, REQUIREMENTS AND D. GLASS IN INTERIOR DOORS AND/OR SIDELIGHTS SHALL BE TEMPERED / 10 01 INSTALLATION: ALL ITEMS SHALL BE INSTALLED IN STRICT ACCORDANCE OMISSIONS OF THE CONTRACTORS,SUBCONTRACTORS OR ANY OF THEIR SPECIFICATIONS WITH THE RESPECTIVE MANUFACTURER'S PUBLISHED INSTRUCTIONS AND 28 ELECTRONIC SAFETY AND SECURITY AGENTS OR EMPLOYEES, OR ANY OTHER PERSONS PERFORMING ANY OF THE E. ALL EXTERIOR DOORS AND DOORS INTO GARAGE SHALL HAVE WEATHER APPROVED INSTALLATION DRAWINGS WORK. STRIPPING AND METAL THRESHOLD 28 01 SECURITY SYSTEMS SHALL BE COORDINATED WITH HOMEOWNER, D. CONTRACTOR TO VERIFY ALL DIMENSIONS PRIOR TO ANY CONSTRUCTION AND 05 METALS 11 EQUIPMENT PERMIT IS BY OTHERS. CONTRACTOR TO COORDINATE PREP WORK NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. F. REFER TO DOOR & WINDOW SCHEDULES FOR ADDITIONAL INFORMATION & 11 01 RESIDENTIAL APPLIANCES: REFER TO PLAN FOR QUANTITY AND LOCATION AND INSTALLATION 05 01 CONTRACTOR SHALL PROVIDE SHOP DRAWINGS TO ARCHITECT SPECIFICATIONS AND COORDINATE WITH OWN€R FOR APPLIANCE (MODEL) SELECTION E. CONTRACTOR TD NOTIFY THE ARCHITECT PRIOR TO ANY WORK IF FIELD OR FOR REVIEW AND APPROVAL OF STRUCTURAL METAL 31 EARTH WORK SITE CONDITIONS PROHIBIT EXECUTION OF DETAILS AND PLANS AS PERMITTED. 09 FINISHES 31 01 EARTHWORK F. ARCHITECTURAL DWGS, SHALL BE USED IN CONJUNCTION WITH STRUCTURAL, 06 WOOD, PLASTICS AND COMPOSITES 09 01 REFER TO FINISH SCHEDULES FOR MANUFACTURER, LOCATIONS, AND COLORS, OF FINISHES. ARCHITECT WILL COORDINATE COLOR SELECTIONS a. PERFORM ALL WORK IN THIS SECTION IN CONFORMANCE WITH THE MECHANICAL, ELECTRICAL PLUMBING & SITE SPECIFICATIONS DWGS SUCH AS 06 01 ALL WOOD IN CONTACT W/MASONRY OR STEEL TO BE PRESSURE AND FIXTURE SELECTIONS PRIOR TO CONSTRUCTION 12 FURNISHINGS FINAL SOILS, COMPACTION, AND GEOLOGICAL REPORTS CIVIL, SURVEY, SOIL TEST AND SITE PLAN, TREATED 12 O1 MANUFACTURED WOOD CASEWORK REFER TO PLANS FOR SIZE$ AND LOCATIONS b. FOUNDATIONS SHALL BE MONOLITHIC OR SPREAD FOOTINGS BASED G. UNLESS SITE SPECIFICATIONSALL ARE PROVIDED ARCHITECTURAL DWGS WILL BE 06 02 SHOP FABRICATED WOOD TRUSSES 09 02 GYPSUM BOARD ASSEMBLIES 0. b. CABINETRY BOXES AND DOORS TO BE CONSTRUCTED OF PLYWOOD ON A SOIL BEARING CAPACITY OF 2500 PSF. FINAL WRITTEN VOIDED. REPEATING OF THESE DRAWINGS WITHOUT WRITTEN PERMISSION OF A. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS TO ARCHITECT FOR REVIEW AND APPROVAL A. STANDARDS: ALL WORK SPECIFIED HEREIN SHALL BE IN ACCORDANCE OR HARDWOOD VERIFICATION SHALL BE SENT TO THE OWNER AND ARCHITECT PRIOR FINNVOLD ARCHITECTURE INC. IS UNLAWFUL AND WILL BE SUBJECT TO LEGAL WITH THE "AMERICAN STANDARD SPECIFICATIONS FOR THE TO THE START OF CONSTRUCTION RECOURSE (INCLUDED BUT NOT LIMITED T0: REPEAT FEES, FINES, LITIGATION B. COMPONENT AND CLADDING PRESSURE IS RECOMMENDED FOR APPLICATION AND FINISHING OF GYPSUM WALLBOARD", AS APPROVED 12 02 COUNTERTOPS: REFER TO FLANS FOR COUNTER TOP AND BACK SPLASH 31 02 SELECTIVE TREE AND SHRUB REMOVAL FEES, ETC.) WIND PRESSURES FOR TRUSS DESIGN, TRUSS ENGINEER IS BY THE AMERICAN STANDARDS ASSOCIATION, LATEST EDITION. SIZES AND LOCATIONS. COORDINATE WITH MANUFACTURER SPECS. 0. WHEN CLEARING PROPERTY, DO NOT DISTURB NATIVE TREES WITH A RESPONSIBLE FOR THE PERFORMANCE OF THE TRUSS SYSTEM APPLICABLE HEREOF ARE HEREBY MADE A PART OF THIS TRUNK THICKNESS OF 6" OR GREATER, UNLESS IN THE FOOTPRINT H. ALL CODES HAVING JURISDICTION SHALL BE OBSERVED STRICTLY IN THE SPECIFICATION EXCEPT WHERE MORE STRINGENT REQUIREMENTS ARE OF THE FOUNDATION CONSTRUCTION OF THE PROJECT INCLUDING A N ALL APPLICABLE STATE, CITY A C. ANCHORS AT WALLS AND SUPPORTS SPECIFIED I ORTS SHALL BE AS SPECI ED N CALLED FOR IN THIS SPECIFICATION, IN LOCAL CODES, DR BY THE 31 03 FILL COMPACTION AL, MB NG, LIFE SAFETY COUNTY BUILDING ZONING ELECTRIC MECHANICAL PLUMBING, THE STRUCTURAL DRAWINGS NOT U P REACTIONS DON USE UPLIFT FI EA MANUFACTURER NU RER OR THE GYPSUM WALLBOARD WHOSE REQUIREMENTS E a OLLO L RE 0 0 LS AND NFORM TION FOLLOWING SOIL REPORT FOR SPECIFIC DETAILS INFORMATION AND FIRE CODES. THE CONTRACTOR SHALL R S VERIFY ALL CODE REQUIREMENT FROM TRUSS CALCULATIONS R CULATONS FOR CONNECTORS , SHALL BE FOLLOWED. 22 PLUMBING REGARDING THIS SITE. FILL SHALL BE CLEAN, WELL GRADED SAND AND THE CONSTRUCTION DOCUMENTS AND BRING ANY CONCERNS TO THE 22 01 REFER TO PLUMBING DRAWINGS FOR NOTES, REQUIREMENTS AND MATERIAL FILL SHALL BE PLACED IN LIFTS OF NOT MORE THAN 12" ATTENTION OF THE ARCHITECT. 07 THERMAL AND MOISTURE PROTECTION B. ALL GYPSUM BOARD SHALL BE 5/8" THICK, FINISHED AND PAINTED SPECIFICATIONS AND COMPACTED TO 95% MODIFIED PROCTOR (ASTM D1557). AT ALL BATHROOMS TO HAVE DENSEESSHIELD OR DENSARMOR MOISTURE 22 02 RESIDENTIAL PLUMBING FIXTURES LEAST ONE DENSITY TEST SHALL BE MADE PER 2500 S.F. OF 01 02 SHOP DRAWINGS, PROJECT DATA AND SAMPLES 07 01 REFER TO ENERGY CALCULATIONS FOR MINIMUM REQUIRED RESISTANT BOARD THROUGHOUT AND REDGUARD WATERPROOFING OR A. REFER TO PLUMBING PLANS FOR FIXTURES QUANTITY AND LOCATIONS COMPACTED AREA (VERIFY WITH SOIL REPORT). THE RESULTS OF A. THE CONTRACTOR SHALL SUBMIT (3) THREE COPIES OF REVIEWED AND R—VALUES, SHGC AND SC OF BUILDING INSULATION EQUAL B. FIXTURES ARE SELECTED WITH HOMEOWNER PROCTOR TEST(S) AND FIELD DENSITY TEST(S) SHALL BE FURNISHED STAMPED SHOP DRAWINGS OF ALL FABRICATED ITEMS AND EQUIPMENT FOR C. AIR HANDLER CLOSETS SHALL HAVE DENSARMOR BOARD ON INSIDE TO THE ARCHITECT/ENGINEER THE ARCHITECT'S REVIEW PRIOR TO FABRICATION AND COMMENCEMENT WITH THE WORK 07 02 ATTIC INSULATION SHALL BE R-20 MIN. ICYNENE. CONTRACTOR TO 09 03 NON STRUCTURAL METAL STUD FRAMING: METAL STUDS SHALL BE 25 GA. 22 03 RESIDENTIAL GAS APPLIANCES A. REFER TO PLUMBING PLANS FOR FIXTURES QUANTITY AND LOCATIONS 33 UTILITIES B. ALLOW 14 DAYS FROM ARCHITECT'S RECEIPT OF SHOP DRAWINGS FOR COORDINATE ENERGY CALCULATIONS WITH REQUIRED INSULATION VALUE. MINIMUM, SPACED AT 16" O.C. B. FIXTURES ARE SELECTED WITH HOMEOWNER 33 01 UTILITIES: CONTRACTOR TO COORDINATE REQLIIREMENTS WITH REVIEW TIME 07 03 PROVIDE LIQUID FLASHING AS REQUIRED TO ALL NEW OPENINGS 09 04 ALL TILES OR STONE IN BATHROOMS SHALL HAVE A SLIP RESISTANT UTILITY, GAS AND SEPTIC COMPANIES PRIOR TO CONSTRUCTION. " COEFFICIENT 0.6 MIN. (WHEN WET) AND BASE MATERIAL CONTRACTOR T V. RIFY CONDITIONS AND LOCkTION PRIOR ANY 01 03 TEMPORARY EROSION AND SEDIMENT CONTROL 07 04 3a RIGID INSULATION R:4.4 MIN. OR EQUAL FOIL INSULATION WORK PER ORO A. CONTRACTOR TO MAINTAIN SILT FENCE DURING CONSTRUCTION, AND REMOVE FROM THE PROPERTY WHEN CONSTRUCTION IS COMPLETE 09 05 PAINTIINCj3 ALL STUCCO AND GYPSUM BOARD SURFACES SHALL BE PAINTED WITH BENJAMIN MOORE OR SHERWIN WILLIAMS PAINT. B. REFER TO SITE PLAN FOR SILT FENCE DETAILS 8000 N. FEDERAL HWY. SUITE 118 BOCA RATON, FL 3 3 4 8 7 P. 561 306 4286 F. 561 953 5210 LICENSE # A A 26002586 ALLDESIGNSAND DETAILS INDICATED OR REPRESENIEDBY 1HISDRAWINGAREFORTHE USEON AND IN CONJUNCTION WITH THE SPECIFIED PROJECT. THIS ISTHE PROPERTY OF FINNI ARCHITECTURE, INC. AND SHALL NOT BE USED OR REPRODUCED WHOLE OR IN PART WITH OUT WRITTEN PERMISSION OR BE LIABLE FOR THE FULLEST LEGAL RECOURSE, THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS AND NOTIFY THE ARCHITECT OF ANY DBSCREPANCIES PRIOR TO THE EXECU[ION OF THE WORK. NEW RESIDENCE FOR MR. CESPEDES PARCEL ID 3224-111-0002-000-2 C-24 CANAL RD SAINT LUCIE COUNTY 2.27.17 1701 REVISIONS PERMIT SET 41a.n7 CONSULTANTS y� Vv PARTITION LEGEND TYP. EXTERIOR WALL — 5/8" STUCCO ON 8" CONIC. BLOCK ON BOTH SIDES. PAINT BOTH SIDES 7' HIGH WALL — 5/8" STUCCO ON 8" CONC. BLOCK ON BOTH SIDES. PAINT BOTH SIDES. DENOTES COLUMN. STEEL COLUMN WITH DECORATIVE WRAP (TYP) ON CONCRETE BLOCK BASE WITH STONE VENEER SYMBOLS LEGEND ® NEW DOOR SYMBOL NEW WINDOW SYMBOL y� ELEVATION MARK T 4 Pc.} 2 INTERIOR ELEVATION MARK 3 — ELEVATION TARGET x SECTION MARK KEYNOTES O36" HT, 24" DEEP BASE CABINETS WIDTHS VARY. SEE PLANS OB 24"x4B" ATTIC ACCESS W/PULLDOWN LADDER, PROVIDE 100 S.F. AREA OF 5/8" PLYWOOD AROUND ATTIC ACCESS FOR STORAGE SUPPORT OC 12" DEEP UPPER CABINETS DO SINK WITH DISPOSAL Ea FULL HT TILE BACKSPLASH, TYPICAL OF TV & OUTLET & CABLE CONNECTION 05'-0" A.F.F. COORDINATE LOCATION IN FIELD WITH HOMEOWNER. GO SUMMER KITCHEN BUILT-IN. STL MT STUDS WITH DURAROCK AND STUCCO O PRE-FAB WATERPROOFED SHAMPOO CUBBY OINSTALL TANKLESS WATER HEATER WITH THERMOSTATIC CONTROL VALVES FOR HOT WATER AS REQUIRED. O TOILET PAPER HOLDER KO TOWEL BAR LO BEVELED MIRROR OM ICE MAKER NO UC REF. FLOOR PLAN NOTES 1. GLAZING WITHIN 36" HORIZONTALLY AND 60" VERTICALLY OF SHOWERS/TUBS SHALL BE CAT. II SAFETY GLASS PER 2405.2 FBC. 2. GLAZING ON EXT. DOORS AND SIDELIGHTS SHALL BE CAT. II SAFETY GLASS AS PER 2411.3.1.3. FBC. 3. SHOWERS/TUBS SHALL HAVE FLOORS AND WALLS TO 70" OF NON —ABSORBENT MATERIALS AS PER 1204.3 FBC. 4. WALL HUNG FIXTURES AND CABINETS SHALL BE SUPPORTED AS PER 2510.5 FBC. 20 GA MTL STUDS 0 W O.C. W/ HORIZ. REINF. 5. BUILDING SHALL HAVE PRE —CONSTRUCTION TREATMENT PROTECTION AGAINST TERMITES AS PER 1816.1.7 FBC. 6. MIN. CEILING HEIGHT SHALL. BE 7'-0" AS PER 1203.2.6 FBC. 7. PROVIDE GROUTED CELL OR COLUMN AT BEARING POINT OF EACH GIRDER TRUSS. 8. ALL EGRESS WINDOWS TO COMPLY WITH F.B.C. AN OUTSIDE WINDOW OR DOOR OPERABLE FROM THE INSIDE WITHOUT THE USE OF TOOLS AND PROVIDING A CLEAR OPENING OF NOT LESS THAN 20" WIDE X 24" HIGH AND 5.7 SQ. FT. THE BOTTOM OF THE OPENING SHALL NOT BE MORE THAN 44" ABV. THE FLOOR. 9. EVERY CLOSET DOOR LATCH SHALL BE SUCH THAT CHILDREN CAN OPEN THE DOOR FROM THE INSIDE OF THE CLOSET. 10. EVERY BATHROOM DOOR LATCH SHALL BE DESIGNED TO PERMIT THE OPENING OF THE LOCKED DOOR FROM THE OUTSIDE IN AN EMERGENCY. 11. EVERY SLEEPING ROOM SHALL HAVE AN EMERGENCY ESCAPE AND RESCUE OPENING AT A MAXIMUM HEIGHT OF 44" TO SILL FBC R310.1 ALSO READ NOTE #8 THIS SHEET. 12. OPERABLE WINDOWS WITH A SILL LESS THAN 36" A.F.F.,WHERE THE FLOOR HAS A DROP OFF MORE THAN 4'-0', REQUIRE SAFEGUARDS AT NOT LESS THAN 42" IN HEIGHT (CHECK FOR REQUIRED ESCAPE OPENING DIMENSIONS WHEN THIS CONDITION) FBC 2411.4.1 13. ALL PRE —FABRICATED BUILDING ELEMENTS TO HAVE ENGINEERED SHOP DWGS. SUBMITTED TO THE VILLAGE OF PINECREST BLDG, DEPT. FOR RENEW AND APPROVAL PRIOR TO FABRICATION & INSTALLATION. NOTES TO CONTRACTOR 1. GLAZING IN WINDOWS AND DOORS, FIXED GLASS, ETC. SHALL BE IMPACT RESISTANT OR COMPLY SFBCR SECTION 4410.4 2. IF STORM SHUTTERS ARE USED, THEY SHALL BE APPROVED BY PRODUCT CONTROL SECTION AND SHALL BEAR THE NAME OF THE COMPANY GRAVED IN EVERY SECTION OF THE SYSTEM. (COMPLY WITH SECTION 4410.4 SFBCR 3. WHEN OUTLETS ARE IN BACK -SPLASH, COORDINATE COLOR TO MATCH, TYP. 4. ALL CABINET BOXES TO BE CONSTRUCTED OF PLYWOOD. NO PARTICLE BOARD CABINET BOXES. ELDORADO STONE-bENEER REBAR (WHERE OCCURS) MORTAR SETTING BED MORTAR JOINT CMU WALL OVER CMU WALL NORTH FLOOR PLAN SCALE: 3/16" = 1'-O" POOL PAVILION _ ...... VAULTEDCOUNG$ ____. _...... _-_-__......... 4 U. VAULTED VAULTED _ CEI ING ? C�IUNG �Q _ oU Z - -.... J w 4 ... > v.. REFLECTED CEILING PLAN SCALE: 3/16" = 1'-O" METAL ROOF. BRONZE FINISH N DENOTES 6" ALUM. GUTTER I 7 9 T I:y��Tl7 ROOF PLAN SCALE: 3/16" = 1'-0" NOW 103 d —7 i OPEN TO EXTERIOR LOUVERED PANEL F'H WALL MPACT VEXT DR CO. :D OUTSWI DOOR (8' IMPACT VEXT DR CO.) D OUTSWING DOORS STANDING SEAM MTL ROOF. — BRONZE FINISH r.o.B. ---------8•—O" DOOR HEADER STONE VENEER AND STONE LEDGE DENOTES LOUVERED PRIVACY DOOR/PANEL ® SHOWER NORTH ELEVATIO SCALE: 3/16" = 1'-O" +Tfi'-s• \_ RIDGE T.O.B. — — — — — B•-0" DODR ROOF SCHEDULE PRODUCT APPROVAL MANUFACTURER DESCRIPTION COLOR 13-0228.06 SOUTHEASTERN METAL STANDING SEAM METAL BRONZE FINISH MANUFACTURING CORP. ROOF DOOR SCHEDULE N0. LOCATION DESCRIPTION SIjE WIDTH HEIGHT THICK MATERIALS HARDWARE REQUIRED WIND PRESSURE PROD. APP. # RATED PRESSURE FRAME FACE CORE LOCKSET D100-4 GARAGE SIDE LH.S.S. SERIES S-808—IL OUTSWING STEEL LOUVERED IMPACT 2'-8" 8'--0' -- -- STEEL STEEL STEEL STEEL STEEL STEEL DEADBOLT/LOCKSET DEADBOLT/LOCKSET +49.16/-52.48 PSF +49.16/-52.48 PSF 15-0728.04 15-0728.04 +70.0/—' 0.0 PSF +70.0/-70.0 PSF D101-4 GARAGE SIDE D.D.S.S. SERIES S-808—IL OUTSWING STEEL LOUVERED IMPACT (2)2'-8" 8'-0' NAVD) 1 SOUTH ELEVATION SCALE: 3/16' = 1'-0" _ _ 15'-3" _ T.O. RIDGE :TANDING SEAM METAL ROOF OVER 30 LB FELT TIN TAGGED UNDERLAYMENT ON EXT. GRADE PLYWOOD MIN 19/32"THICK WITH 32/16 APA SPAN RATING OVER PRE—FAB TRUSSES OVER 3X8 EXPOSED RAFTERS PAINTED WITH 2X6 T&G #1 SELECT CYPRESS DECKING (FIN. WITH CLEAR SEALER OR STAIN TBS) FASCIA —2X6 CEDAR FASCIA BOARD PAINTED TYP. (BACK PRIME FASCIA BOARD PRIOR TO INSTALLATION) WITH P.T. 1X2 NAILER & GALVALUME METAL DRIP EDGE TO MATCH ROOF. STEEL COLUMNS WRAPPED WITH DECORATIVE AZEC OR FIBERGLASS COL MATCH EXISTING COLUMNS IN MAIN HOUSE PORCH CONCRETE BLOCK BASE WITH STONE VENEER CONCRETE SLAB WITH 6x6 W14A4 - WWF ON 6 MIL VAPOR BARRIER ON, CLEAN COMPACTED SOIL TREAD AGAINST TERMITES. REFER TO STRUCTURAL DWGS FOR DETAILS DENOTES COLUMN FOOTINGS BEYOND. REFER TO STRUCTURAL DRAWINGS FOR DETAILS DENOTES MONOLITHIC SLAB. REFER TO STRUCTURAL DRAWINGS FOR DETAILS n'-n" 19r n'Nlsvry _ FINNVOLD ARCHITECTURE, INC. — — — — 8000 N. FEDERAL HWY. SUITE 118 BOCA RATON, FL 3 3 4 8 7 P. 561 306 4286 F. 561 953 5210 LICENSE # A A 26002586 WEST ELEVATION SCALE: 3/16" = l'-O" 12 4 CLG MOUNTED TV AND \ BRACKET. CONTRACTOR TO COORDINATE W 7)j OWNER DENOTES BEAM REFER TO STRUCTURAL DRAWINGS FOR DETAILS. EXPOSED 3x8 RAFTERS W/ 2x6 T&G DECKING DECORATIVE FAN/LIGHT FIXTURE COOR. WITH OWNER SECTION SCALE: 1 /2" = 1'-O" ALL DESIGNS AND DETAILS INDICATED OR REPRESENTED BY THIS DRAWING ARE FOR THE USE ON AND IN CONJUNCTION WITH THE SPECIFIED PROJECT. THIS IS THE PROPFRTY OF FINNVOLD ARCHITECTURE, INC. AND SHALL NOT BE USED OR REPRODUCED WHOLE OR IN FART WITH -OUT WRITTEN PERMISSION OR BE LIABLE FOR THE FULLEST LEGAL RECOURSE. THE CONTRACTOR SHALL VERIFY Al 1- EXISTING CONDITIONS AND DIMENSIONS AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES PRIOR TO TI IF FXFCUTION OF THE WORK. i. +lfi•-s• NEW RESIDENCE FOR MR. CESPEDES PARCEL ID 3224-111-0002-000-2 C-24 CANAL RD SAINT LUCIE COUNTY 2.27.17 1701 REVISIONS PERMIT SET 4.26.17 CONSULTANTS FLM&,;PLAN Mk ELEVATIONS CNFFT It _ ns TE-Ta STEEL COLUMNS z�.a^ F 48 TE-12 TE-TB MF-24 :®.I® ■ ■■ ------------------------- —I-------- rj I — J L—_--J IF --- ■ j C1 48" 0. ■ I I I 4 I I I I � ■ I I I T-10" I I I I I j 4" SLAB ONTYPICAL GR D I L----� I I W/6x6, WI.4xM.4 W.W.M. ■ ■ L___r TF I I I I I ■ I I I ■ I � r�C I TIER a,1o:, C1 48" O.Ct I I uJ'ER I ■ I —�-1 r-----I I I I -----t LJ ■ ---------- ®® I ■ ■ TE-T I I �F 48 TE-TF MF-24 FOUNDATION PLAN 3116' = r-O" CONCRETE FOUNDATION SCHEDULE MARK SIZE REINFORCEMENT REMARKS BOTT TOP MIDDLE MF-24 24"W X16"D 2 #5 1 #5 SEE DETAIL CONT. CONC. FTG. TE-12 12 xi2 CONCRETE CONT.FOOTING 1 #5 SEE DETAIL F 48 48" X 48"X 24" DP 2-ROWS 2-ROWS SEE DETAIL CONCRETE FOOTING 5#5 5#5 F 56 56" X 56"X 24" DP CONCRETE FOOTING 2-ROWS 2-ROWS 5#5 SEE DETAIL CONCRETE COLUMN SCHEDULE REINFORCEMENT MARK SIZE HOOPS REMARKS D C-1 8"x 8" 1# 5 NONE 3000 PSI FILLED CELL ® C_ 8% 12" CONC. COLUMN 4 # 5 # 3 AT 12- O.C. 3000 PSI ■ 12"x 12" CONC. COLUMN 4 # 5 # 3 AT 12" O.C. 3000 PSI ® 3.5" X 3.5" X 1/4" STEEL COLUMN SEE STEEL COLUMN DETAIL ® C-1 6" X 6" X 3/8" STEEL COLUMN SEE STEEL COLUMN DETAIL CONCRETE BEAM SCHEDULE MARK SIZE REINFORCEMENT REMARK NOTES BOTT TOP MIDDLE 8"x 8" VARIES L-1 LINTEL 1 #5 SEE ELEV. L-2 8"x 16" 1 #5 1 #5 VARIES LINTEL SEE ELEV. BB-1 8"x 16" 1 5 # 1 #5 VARIES BOND BEAM SEE ELEV. 8"x 24" #3 STIRRUPS VARIES B-1 CONC. BM. 2 #6 2 #6 2 #6 @ 6" O.C. SEE ELEV. B-3 8"x 18" CONC. BM. 2 #5 2 #5 2 #6 #3 STIRRUPS VARIES SEE ELEV. ® 6" O.C. ADD # 5 REBAR FOR VERY ADDITIONAL 6" IN DEPTH OF BEAM C1 48" DOUBLE MESH @ FOOTER w/ (3) #5'S CONT. , w/ (3) #5'S CONT. STANDARD MF1 CONTINUOUS FTG d • J'. a A . ^� d w/ (3 #5'S CONT. 24" MFi INTERIOR FTG (off 8RG WALL MESH 1-#5 CONT.- 3" MIN. COVER 12' SHOWER RECESS TE12 THICKENED EDGE PAD REBAR EDGE BARS -ALWAYS, REMAIN - SPACE 1 OTHERS EQUALLY I I ' SEE PLAN EXERIOR PAD AT.COLUMN la Is's1 -- -- I I o J1 ° . IBB-1' r PITCH I I I❑ m 1 �ICl.7J ❑ L , E E. ROOF PLAN STRUCTUAL NOTES ALL STRUCTURAL LUMBER # BE SYP#2 MIN, CONCRETE SLAB TO BE 2500 PSI AT 28 DAYS SOIL BEARING 2500 PSF ALL REINFORCING STEEL A-615 GRADE 60 CONCRETE BEAMS TO BE 3000 PSI AT 28 DAYS 0 INDICATES TYPICAL Cl COLUMN 8" x 8" FILLED CELL W/ 1 # 5 3000 PS1 CONCRETE STEEL COLUMN(SEE PLAN) ANCHOR BOLTS - SEE MANUFACTURES SPECS r— GRADE 61-6. Ell 3116' = r-O" REINFORCED MASONRY WALL NOTES 1. HOLLOW LOAD -BEARING MASONRY UNITS SHALL CONFORM TO ASTM C-90, TYPE I, GRADE N, SQUARE END, WITH A MINIMUM AVERAGE COMPRESSIVE STRENGTH ON NET AREA OF f'm=2,000 (PSI). CONSTRUCTION SHALL BE IN ACCORDANCE WITH ACI 530.1 SPECIFICATIONS. 2. QUALITY ASSURANCE INSPECTIONS ARE REQUIRED FOR ALL REINFORCED MASONRY CONSTRUCTION. THE INSPECTOR SHALL INSPECT THE FOLLOWING: A. PLACING OF THE REBARS IN THE CELLS (POSITION IN THE CELL, LAPPING AND SPLICES, BAR SUPPORT AT 10 FT. HEIGHTS). B. VERIFY CLEANLINESS OF THE CELLS TO BE GROUTED. INSPECTION HOLES AND THE BOTTOM OF THE POUR AND MORTAR PROJECTING INTO CELLS TO BE GROUTED. C. OBSERVE AND BE PRESENT DURING THE PLACING OF THE GROUT OR CONCRETE INTO THE VERTICAL CELLS. D. THE ABOVE APPLIES FOR MASONRY BEAMS AND BOND BEAM INSPECTION AS WELL. 3. MORTAR SHALL CONFORM TO ASTM C-270, TYPE "M". 4. LAY ALL MASONRY WITH FULL FACE HEAD JOINTS AND WITH FACE SHELL MORTAR BEDDING. 5. MASONRY ANCHORAGE TO SUPERSTRUCTURE SHALL BE PROVIDED IN ACCORDANCE WITH STRUCTURAL DRAWINGS AND DETAILS. 6. THE USE OF ADMIXTURES SHALL NOT BE PERMITTED WITHOUT PRIOR REVIEW OF THE ENGINEER. 7. VERTICAL REINFORCING: (A) ASTM A-615 PER REINFORCING SECTION. (B) WHEN A FOUNDATION DOWEL DOES NOT LINE UP WITH A VERTICAL CORE IT SHALL NOT BE SLOPED MORE THAN ONE HORIZONTAL INCH TO SIX INCHES VERTICAL FOR ALIGNMENT, EVEN THOUGH IT IS IN A CELL ADJACENT TO THE VERTICAL WALL REINFORCING. (C) VERTICAL REINFORCING STEEL SHALL BE PLACED CENTERED IN THE CELL. LAP 48 BAR -DIAMETERS. PROVIDE BAR SPACERS AS REQUIRED TO MAINTAIN REINFORCING SECURED IN POSITION (AT 10 FT. VERTICAL SPACING). (D) VERTICAL REINFORCEMENT SHALL BE PROVIDED AT EACH SIDE OF OPENINGS IN WALL, AT WALL INTERSECTIONS, CORNERS AND ENDS, THIS REINFORCING SHALL BE THE SAME SIZE AS THE SCHEDULED WALL REINFORCING FOR THE PARTICULAR WALL BUT NEVER LESS THAN A #5 REBAR. SPECIAL CARE SHALL BE TAKEN TO INSURE THAT CELLS TO BE GROUTED LINE UP PROPERLY AND ARE CLEAN OF EXCESS MORTAR. (E) ALL VERTICAL REINFORCING SHALL BE HOOKED INTO THE BOND BEAMS AT THE NON -CONTINUOUS END OF THE REBARS. (F) PROVIDE INSPECTION HOLES AT THE BOTTOM OF EACH REINFORCED MASONRY CELL, AS REQUIRED FOR LIFTS HIGHER THAN 4 FT. 8. HORIZONTAL REINFORCING: PROVIDE GALVANIZED #9 GAGE, LADDER TYPE HORIZONTAL JOINT REINFORCING EVERY SECOND BLOCK COURSE (1'-4" O.C. VERTICALLY) LAPPED 7-1/2". PROVIDE SPECIAL HORIZONTAL REINFORCING AT "T" AND "L" INTERSECTION. ANCHOR TO COLUMNS WITH MINIMUM 4" EXTENSION INTO AREA OF POUR. CONC. LINTEL 'CASTCRETE' SEE LINTEL SCHK!' LE TYP, BOND BEAM I I COL STL (SEE WALL SE 4" MIN. 4" MIN. (1) # 5 (1) # 5 MIM MDL FORM & POUR SOLID — 6" DP. ( EA. SILL ). I I I I I I � I I I I� I� � � I I I � I I `GONG. NLK W I i -""BOTTOM OF FOOTER L ----------------------------- - ----------------- ----------- ADD ) # 5 FOR OPENINGS GREATER THAN 4'-4" TYP. WINDOW/ M. 0. OPEN'G IN BLK. Yi7 TYP .DOOR/ M. 0. OPEN'G IN BLK. WALL I REVISIONS I BY I CARL G. 0 O� A! mg 0 �a� Q b N< gar aI�N aw0 ba�bm DRAWN BY: CARLOS VnACA 1000 S DIXIE HWY. WEST POMPANO BEACH FLA. 33060 PHONE:561— 445— 9661 EMAIL carlosvilaca203mall.com DATE 1-lo-n SCALE: 3116' = r-r ROJECT NA'IOR� CHURCHILL SHEET NOTES: - ALL 3/4' DIAM. THp� BOLTS TO BE ASTM A325. - ALL 14 STEEL PTL .TES TO BE ASTM A38. - ALL ECIRED MATERIALS ABOVE TO BE EQUAL - _'ORBETTER. AYLOE7N CONNECTIONS. BOTHOLESTB/8DAM. FOR 33/4' AMBOLTS gUrKFT UPLIFT L $�HRU BOLT INMT LOAD PERPENDICULAR TO GRAIN = 1330 LBS 31,1 N 31f' 11/I' LOAD PARALLEL TO GRAIN = 2,550 L'BS 10• % 10. 3/4" - NTH SHORT DURATI(jN"LOAD FACTOR CD=1.33 USING 1.3 FACTOR,1, LBS x 1.3 = 1,729 LBS/BOLT 4-3/4' OF BOLTS strap (SEE 3 STUCCO SC REINF. (SEE B'. w1.e�aM REINF, W 1# SEE P 4 0 6'-0" O,C, LL PPLIED WOOD BASE. EXP. JOINT CEALL LLS SOLID FOUNDATION fSMCOTH4" CONC: SLAB W/Bx8-10/10 MESH ON 4 HIM VLSQULEN VAPOR BARRIER EL. 100'-0" 9' DOUBLE MESH ®FOOTER GRADE : - b e x // ZCOMPACTED TREATED FILL 17 SEE SCH. WALL SECTION W/ 2' OVERHANG ROOF SUPERIMPOSED LOADING ROOF ZONE (TYP.) ZONE (TYP.) LIVE = 3OPSF(SUPERIMPOSED) DEAD = 25PSF (10 PSF FOR UPLIFT) A -ZONE (TYP.) ZONE (TYP.) \C:.. ..-..-.. -.7 G\...%....i:: :3iiii:?:%... is.../ A -ZONE ROOF WIND ZONE DIAGRAM A.)#5 TOP & BOTTOM BEAM DETAIL) ZONE 1 : -38.33 PSF ZONE 2 : -64.21 PSF ZONE 3 : -64.21 PSF A -ZONE :4.45 FEET WIND ZONE PRESSURE DIAGRAM 9 GA HORIZONTAL REINFORCEMENT # 5 DOWN BAR 36" ABOVE SLAB 12" HOOK AT FOOTING REINFORCED FILLED CELL SEE PLAN FOR SIZ[ AND SPACING. 1/4„ 4„ 16 d nl 8"Xa"X16" 11� n 'm KNOCK OUT 1/4" W/2-6/8" A.B. RECESS CONCRETE 2' BASE PLATE STEEL COLUMN PLATE DETAIL STEEL COL TO CONCRETE BEAM Ti19 t''1e 9 GAUGE HORIZONT, REINFORCEMENT EVERY OTHER COUR 8" x 8" x 16" ONCRETE (LADDER TYPE) MASONRY UNITS BLOCK REINFORCEMENT CORNER DETAIL 5/8" CDX APA RATED PERPENDICULAR TO ry TRUSSES 2 X FASCIA WITH 3 -16D ROOF TRUSSES 24" O.C. \y 2X4BLK 24"O.0 4"-0" AT GABLE ENDS ZONE PLAN ROOF SHEATHING SHEATHING SCHEDULE LOCATION PANEL FASTENERS SPACING /ZONE WALLS 5/8" CDX 8d 6" O/C EDGES /ZONE 4 APA RATED ring shank 4" O/C EDGES/ZONE 5 5/8" CDX ROOF 8d 6" O/C EDGES ZONE 1 /ZONE 2 APA RATED ring shank 4 O/C EDGES ZONE 3 PLYWOOD ROOF DECKING AND DIAPHRAGM A. SHALL BE 19/32" MINIMUM THICKNESS, 'CDX" TYPE AND SHALL BE CONTINUOUS OVER THREE OR MORE SPANS, WITH FACE GRAIN PERPENDICULAR TO THE SUPPORTS. B. CONNECT PLYWOOD ROOF DIAPHRAGM TO STRUCTURE WITH 8d RING SHANK. NAILS, 2x4 BTM. CHORD BRACING 72" O/C MAX., SECURED W/ (2) 10d COMMON NAILS AT EACH CHORD INTERSECTION, TYP. 2x4 DIAGONAL B-N. CHORD BRACING, SEE P FOR LOCATION BTM. CHORD OF WOOD ROOF TRUSSES BOTTOM CHORD BRACING NTS 2x4 #2 SOUTHERN YELLOW PINE CROSS BRACING MEMBERS FASTENED TO TRUSSES W/4-16d NAILS EACH END (REFER TO TRUSS NOTES, TRUSS LAYOUT AND NOTE BELOW FOR LOCATION) 2x4 CONT. LATERAL WOOD BRACING NAILED TO BOTTOM CHORD MAXIMUM 6'-0" SPACING AND AS REQUIRED BY TRUSS MANUFACTURER (REFER TO TRUSS NOTES AND TRUSS LAYOUT FOR LOCATION) TYPICAL X/BRACE DETAIL NTS REVISIONS I BY N � o a T Lo w rn �, IE 4 � X F+�1 O ��lyl 0 w O J J �Uw co Ld 'hhhj^+++y�444 N w 00 co C ) U 4 rn Qo R2_ w a DRAWN T BY: CARLOS VR ACA POMPANO XBEACHY FLA. 33060 PHONE:561- 445- 9661 EMAIL: carlosvilaca2®Gmail.com DATE 3-1-1% SCALE: Y16'=Mr PROJECT: NOMPM-CE3PIEDES MECHANICAL PLAN (NO AC ) = r-O" 1/47 FAN SCHEDULE o COMPANY: PANASONIC FAN NO. EF- 1 AREA SERVEp TOILETS CFM 50 RPM 1075 WATTS 14 AMPS .11 VOLTAGE 120-1-60 FAN TYPE CEILING CONTROL LT. SWITCH EF-1 WITH BACKDRAFT DAMPERS_ GALVANIZED EXAUST ROOF CAP W/BACKDRAFT DAMPER SLOPED ROOF CAP. WIRE MESH SCREEN INSTALLED SLOPED 2x4 WOOD BLDCKI G J� 4' GALV. METAL DUCT 26 GA. BACKDRAFT DAMPER 4CEILING NUTONE EXH,FAN GRILLE SIZE AS PER AIR MFR. SPEC'S EXHAUST EA DETA N.T.S. I i6 1 / I � I I I I I II� � I I ELECTRICAL PLAN I/if = 1'-0, NEW ELECTRICAL "PAVILION" SUB-PANFI � 100A M. C. B PANEL 120 / 240v 1N 3W (SURFACE) CET SERVES CB P KW WIRE-COND. CKT SERVES CB P KW WIRE-COND. 02 FAN/LIGHT 15 1 .8 # 14 01 WP/GFCI RECEPTACLES 20 1 1.5 # 12 04 GENERAL LIGHTS 15 1 .8 # 14 03 WP/GFCI RECEPTACLES 20 1 1.5 # 12 06 PXSTRGOM LIGHTS 15 1 .8 # 14 05 WP/GFCI RECEPTACLES 20 1 1.5 # 12 08 POOL LTGS -- -- 07 RESTROOM GFCI RECEP 20 1 1.5 If 12 10 POOL PUMP -- -- 09 WATER FALL PUMP 20 1 1.5 # 12 12 POOL FILTER -- -- 11 ICE MAKER 20 1 1.5 # 12 14 JACUZ$I PUMP -- -- 18 SPARE -- -- 16 9PAR1, -- -- 15 SPARE -- -- 18 SPARE -- -- 17 SPARE -- -- 20 SPARE -- -- 19 SPARE -- -- C.4 FI F[.TRIrAi KlnTCC- 1 ALL ELECTRICAL WORK SHALL CONFORM TO THE LATEST REVISION OF THE N.E.C. 2011 AND LOCAL GOVERNING CODES 2. ALL WIRING TO BE COPPER UNLESS OTHERWISE NOTED. 3, ALL MATERIALS, WHERE APPLICABLE, SHALL BE U.L. LABELED 4. ALL MATCH FINISH SH AND INGS REQUIRED FIIRE RATED ELECTRICAL ELECTR CAL CONTRACTOR. CLOSED TO 5. INSTALLATION HEIGHTS ABOVE FINISH FLOOR UNLESS OTHERWISE NOTED: WALL HUNG TELEPHONE 56" A.F.F. TELEPHONE JACKS 12" A.F.F. LIGHT SWITCHES 48" A.F.F. RECEPTACLES 12" A.F.F. TELEVISION JACKS 12" A.F.F. 6. CO-ORDINATE ALL CONDUIT RUNS AND EQUIPMENT INSTALLATION WITH OTHER TRADES TO AVOID CONFLICTS PRIOR TO FABRICATION, INSTALLATION AND ERECTION. 7. ELECTRICAL CONTRACTOR TO VERIFY ALL HVAC UNIT CONNECTIONS WITH HVAC CONTRACTOR PRIOR TO INSTALLATION. B. ALL METERS, METER CENTERS AND DISCONNECTS TO BE APPROVED BY FLORIDA POWER AND LIGHT. 9. LOCATION OF ELEC. REC. SHALL COMPLY W/ NEC-210-52 AND RECEPTACLE SPACING SHALL COMPLY WITH NEC 210-72. LIGHTING OUTLETS SHALL COMPLY WITH NEC-210-8 WALL NEW CIRCUITS TO BE ARC FAULT PROTECTED NEC 2008 210.12 11ALL NEW RECEPTICLES TO BE TAMPER RESISTANT NEC 406.11 9.0 TOTAL 11.4 CERAMIC TILE BOND COAT REINFORMORTAR CB BED ED BACKING CERAMIC TILE INTEGRATED ^DDRAIN BONDED FLANGE L-SLOPED REINFORCED FLOOR MORTAR BED 1-1 3/4' THICK SHOWER DETAIL N.T.S. TO HOUSE TILE PLUMBING PLAN 2' VTR I I ISOMETRIC PLAN PLUNSING NOTES 1. THE ENGINEER CERTIFIES TO THE BEST OF HIS KNOWLEDGE, ALL WORK DEPICTED IS IN ACCORDANCE WITH THE FLORIDA BUILDING CODE, INSTALLATION SHALL COMPLY WITH STANDARDS THEREIN. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL EQUIPMENT DESIGN REQUIREMENTS (I.E. VOLTAGE, WATER, DRAINS, GAS CONNECTIONS, ETC.) WHEN FOR THEAPPROVED OPERATION, THE SHALL BE REQUIREDFURNISHEDWITHCALL ENECCESSARY ACCESSORIES WETH REQUIPMENT CONSIDERED OPTIONAL OR STANDARD BY THE MANUFACTURER EQUIPMENT SHALL NOT BE ORDERED BASED ON MANUFACTURERS' MODEL NUMBERS. 3. ALL MATERIALS AND EQUIPMENT SHALL RE NEW, FREE FROM DEFECTS AND WITH FACTORY WARRANTY, PRODUCTS SHALL BEAR RESPECTIVE A.S.7,11. STANDARD LABELS AND INSTALLED AS PER LISTING UNDER SUCH. 4. INSTALL SANITARY LINES AS TO DRAIN WITH SLOPES OF NOT LESS THAN 1/8' PER FOOT FOR 3' SND ABOVE AND 1/4' PER FOOT FOR 2'. 5. INSTALL PIPING AND EQUIPMENT ALLOWING ADECUATE ACCES FOR SERWCE TO VALVES AND EQUIPMENT OF OTHER TRADES, PROVIDE U.L LISTED ACCESS PANELS IN WALLS AND CEILING WHERE ACCESS IS REQUIRED. 6. INSTALL CLEAN -OUTS AS INDICATED ON DRAWINGS AND AT EVERY 75 FEET, BASES OF STACKS AND CHANCE OF DIRECTION. 7. SANITARY, VENT AND RAIN WATER LEADER PIPING SHALL BE SCHEDULE 40 PVC SOIL PIPE WITH DRAINAGE TYPE FITTING, SOLVENT WELDED. PRIME FITTINGS AND PIPE ENDS PRIOR TO WELDING, EXCEPTION: IN AIR CONDITIONING PLENUMS, Le. MECHANICAL ROOMS, CAST IRON PIPING SHALL BE USED. 8. DOMESTIC WATER PIPE SHALL BE TYPE L ABOVE GROUND AND TYPE K BELOW GROUND. SOLDER FITTINGS USING LEAD-FREE SOLDER, AVOID JOINTS BELOW SLABS OR INSIDE WALL$ WHENEVER POSSIBLE. 9. PROVIDE EXPANSION AIR CHAMBERS OF 20 PIPE DIAMETERS BUT NOT LESS THAN 12'. INSTALL AT EACH FIXTURE, GROUP OF FIXTURES, RISERS AND END OF SUPPLY LINES. 10. ISOU.TE COPPER PIPING FROM DISSIMILAR METAL, MASONRY OR CONCRETE WITH FOAM PLASTIC, FIRE RETARDANT INSULATION OR SIMILAR METHODS APPROVED BY LOCAL JURISDICTION. 11. PROVIDE PIPE SLEEVES FOR ALL CEILING, FLOORS OR WALL PENETRATIONS PAC( WITH FIRE RETARDANT CAULKING IN CONFORMANCE TO U.L SPBJIFICATIONS. 12. PLUMING FIXTURES SHALL BE FIRST GRADE VITROUS CHINA CONFORMING TO LNSI STANDARDS, FURNISH TRAPS, VALVES AND ALL TRIM, COMPLY WITH ALL CODES AND ORDINANCES. A,ERICAN STANDARD OR EQUAL 1/4' = Hr PAVILION POOL BATH M \TlN9 NOTE: PLUMBING FIXTURES, FAUCETS AND FIXTURE FITTINGS TO COMPLY WITH REFERENCED STANDARD AS PER FBC TABLE P2701.1. WATER & SANITARY PIPING MATERIAL MA.TERMAL NOTE: WATER SERVICE PIPING CHLORINATED POLYVINYL CHLORIDE (CPVC) PER FBC 2010 TABLE 605.3 WATER DISTRIBUTION PIPING COPPER PER FBC 2010 TABLE 605.4 SANITARY & VENT PIPES POLYVINYL CHLORIDE (PVC) PER FBC 2010 TABLE 702.1 TABLE 702.2, TABLE 702.3, TABLE 702.4 CARL G. FO"FS i J,� I 55S Po1rlP 6> gI o .. 0 il cc o' j .NQ � 1 ar� U ,C)N Q-N �6 a- 6 DRAWN BY: CARIDS VIUCA 1000 S DIXIE HWY. WEST POMPANO BEACH FLA. 33060 PHONE:561- 445- 9661 EMAIL: corlosvllaca203mall.com DATE 1-Ao-17 SCALE: _m6` = 1'-0' ROJECT 1VA7TOR13 CAU1iCF�],