Loading...
HomeMy WebLinkAboutRevised Approved PlansIF THERE ARE NO MARKUPS ON LAYOUT, THEN TRUSSES WILL BE BUILT AS DESIGNED AND CT WILL NOT BE BACK —CHARGED FOR ANY ITEMS FOUND AFTER THE FACT OF THE RETURNED LAYOUT ALL DIMENSIONS AND CONDITIONS THAT EFFECT WD. TRUSSES MUST BE VERIFIED BY BUILDER AND/OR ARCHITECT BEFORE ANY PRODUCTION OF WD. TRUSSES 0) C) 00 60 TW1 C C 5/12 21 0" `[GM 5/12 9' 8 1 /2" 201011 101511 9' 8 1/2" Do M Q Q Q Q Q Q Q Q Q < Q 7 a— D V ti✓s CD QJti ) V 0 N J 1 J3 J3 EJ5 EJ5 EJ5 �G� EJ5 EJ5 ��� G� EJ5 EJ5 �G S h��ti PJ EJ5 o EJ5 3' 4 EJ5 EJ5 EJ5 EJ5 AD ✓S. EJ5 J J3 J1 J1 M M — 37' 411 VERIFY ALL DIMENSIONS, WALL HGT.s, COL. HGT.s & LOCATION GIRDER LOCATIONS, CLG HGT.s, COFFER CLG. LOCATIONS END DETAILS, PITCH, FASCIA, O.H. & CANT SOME DOWN FRAMING REQ. BY BLDR. DROP CLG., CEILING CHANGE & COFFER CLG. AREAS 21 011 APPROVED TRUSS ANCHOR BY BUILDER PLUMB CUT OVERHANG HEEL HEIGHT = 6 3/6" BOTTOM = 2x4 MIN. TOP = 2x4 MIN. 12 5F'�' 4/12 VAULT r On TRUSS END DETAIL 1X APPROVED TRUSS ANCHOR BY BUILDER SQUARE CUT OVERHANG HEEL HEIGHT = 8" BOTTOM = 2x4 MIN. TOP = 2x4 MIN. 12 5l7 81, 12 5 l7 TRUSS END DETAIL ASCE 7-10 MWFRS )esign Wind Spa 170 mph TCLL 30 40 WildingType: Enclosed TCDL 15 20 -- 'ategory Importance actor: . 11 1.00 BCDL 10 5 oration Factor: _ - - _- --- Roof 1.25 / Floor 1.00 BCLL 0 0 WildingExposure:-- "C" TOTAL 55 65 (live Truss bottom chord analyzed with 10psf non -concurrent load 30 psf concurrent live load on trusses designed with storage space. TRUSS HANGER INFORMATION Check TRUSS ENGINEERING for gravity and uplift values. If the value exceeds the capacity of a hanger shown below, then it is the responsibility of the builder to provide a suitable connection. All 2-ply hanger values are based on a 2-ply supporting girder. HANGER CONN. ROOF FLOOR UPLIFT GIRDER TRUSS 2645 2265 18.16d 1240d 1 11r, 4115 :. 23M 28AW 16-10d 1 112" 2770 2340 18-16E 12-10d 4375 23M 20-IM 8-16d 4375 2340 20-16d 8.16d A TH025 2x6 3060 8 THD28 2x8 4485 C THOM2 2x5 3356 D THOH28.2 2x6 5245 E TH011211-3 2x6 5246 F THD28-2 2x8 am 4310 2595 28-16d 16.1od G THOH28-2 2x8 8025 7360 3330 36-16d 1046d N I THDN28.3 THD48 24e 2x6 7830 3176 75" 2540 4370 2288 36A6d 18-i8d 12-16d 12.10d J RJC25 2X6 3490 2135 1646d 5-10d K SKHH46LIR 2x6 2100 1680 1346 12-16d 6-116d L SKHH26UR 2x5 1890 1510 2190 18-16d 12-00dx142 _ M SKHH26L-2IR-2 AB 2100 1680 1 805 12-1ed 4-16dx2-112 N O GT➢982T 2.8 10900 8720 8436 22 - WS3 16 - WS3 � P G7WS3T 2x8 12470 11100 12490 28 - WS3 24 - WS3 Q OTW34T 2x8 12470 11100 12190 28-WSJ M-WS3 R OR EQUAL nee8on ' 15" 5 1W Tapcon 9.10d g -- T RT76A OR EQUAL nMM.n I byX - - 1380. 8-10d 9-10dx1-1IT' 18.10rix1-112" EQUAL �nbldr.ection - 2760 16-10d Y 2: CONNECTOR BY BLDR "IMPORTANT INFORMATION"* ALL REACTIONS, UPLIFTS, ETC. ARE THE RESPONSIBLITY OF THE ENGINEER OF RECORD, PER LOCAL CODE. REFER TO THE STRUCTURAL FRAMING FOR INFORMATION. CT IS NOT AND WILL NOT TAKE ANY RESPONSIBILITY FOR ANY TYPE OF THIS INFORMATION. THIS INFORMATION IS THE SOLE RESPONSIBILITY OF THE ENGINEER OF RECORD. BEARING HEIGHT DISCLAIMER: IT IS THE SOLE RESPONSIBILITY OF THE ARCHITECT OR PROJECT ENGINEER REGARDING BEAM ELEVATIONS AND BREAK LOCATIONS FOR CHANGES IN BEAM HEIGHTS. CT BEAM HEIGHT SCHEDULE IS A GUIDELINE ONLY. REFER TO ARCHITECTUAL AND STRUCTURAL DRAWINGS FOR THIS INFORMATION. CT IS NOT AND WILL NOT BE RESPONSIBLE FOR THIS INFORMATION. FIELD BRACING is not the responsibility of the truss fabricator, truss designer, or plate manufacturer. Persons erecting trusses am cautioned to seek professional advice regarding temporary and erection bracing which is always required to prevent toppling and dominoing during erection, and permanent bracing which may be required in specific applications. Trusses shall be erected and fastened in a straight and plumb position. Where no direct top chord sheathing is applied, trusses must be braced at 24" on center maximum. Where no direct bottom chord sheathing is applied, trusses must be braced per local code. Trusses must be handled with extreme care during erection to prevent damage or personal injury. Refer to truss engineering for connection and bracing requirements. These calculations are supplied in order for the ENGINEER OF RECORD to adequately provide for connection and Integration of the roof assembly to the supporting structure. Designers of supporting connections are SOLELY responsible for the integrity of their productTmsses remain our property until paid for in full. Truss layouts and engineering may not be reproduced in part or in full under any circumstances. SHOP DRAWING APPROVAL THIS PLACEMENT PLAN MUST BE APPROVED PRIOR TO COMMENCING TRUSS ENGINEERING OR FABRICAITON. THE BUILDER MUST VERIFY THE COORDINATION OF ALL THE INFORMATION IN THIS PLAN WITH THE ARCHITECTURAL OR STRUCTURAL DRAWINGS. ANY VARIATIONS BETWEEN THE FINAL PLACEMENT PLAN AND THE ARCHITECTURAL OR STRUCTURAL PLAN IS THE SOLE RESPONIBILITY OF THE CUSTOMER, AND ANY EXPENSES INVOLVED IN CHANGES AFTER TRUSS FABRICATION IS THE RESPONSIBILITY OF THE CUSTOM AND NOT CUSTO TRU S LLC. Approved By Date: NOTE: Horizontal and Vertical Truss reactions and uplift calculations are provided by CUSTOM TRUSS LLC., for the JOB ENGINEER OF RECORD to accurately provide support for the ROOF TRUSS SYSTEM and for proper connection of the ROOF TRUSS SYSTEM to the sup Ing structure. State of Florida Registered Engineer CARL G. FORBES, PE FL.Reg.Nos 20699 555 W. POMPANO PKWY. - POMPANO BEACH, FL. 33069 (954) 682-6651 Data: Revisions cusTOM Muss 1890 W. ATLANTIC AVE. DELRAY BEACH, FL 33444 PH: (954) 786-8800 FAX: (954) 786-8804 SOLTY PLUMBING Name: CESPEDES RESIDENCE PAVILLION Address: C24 CANAL ROAD FORT C 1' F 4/14/2017 #170465 File MAR 0 2 2018 ST. Lucia County, Penn R-20 FOAM R-4.1 WALLS LOW E GLASS U FACTOR 1.02 SHADING COEF .25 FAN SCHEDULE e COMPANY: PANASONIC FAN N0. EF- 1 AREA SERVED TOILETS CFM 50 RPM 1075 WATTS 14 AMPS .11 VOLTAGE 120-1-60 FAN TYPE CEILING CONTROL LT. SWITCH pp-1 WITH RArLCr1RAFT nampFRC COOLING EQUIPMENT # 8 MAKE LENNOX MODEL XC16SO48 4.0 TON 1600 CFM EFFICIENCY 18 SEER TOTAL BTU 42,000 HEAT PUMP GALVANIZED EXAUST ROOF CAP W/BACKDRAFT DAMPER SLOPED ROOF CAP. 2x4 WOOD BACKDRAFT CEILING MECHANICAL PLAN 1/47 = P-0' HEATING EQUIPMENT # 8 MAKE LENNOX MODEL CBX25UHV-060 EFFICIENCY 100 EFF EFFICIENCY 10.0 KW REF. PIPING 1-1/8 / 7/8 WIRE MESH SCREEN INSTALLED SLOPED 4' GALV, METAL DUCT 26 GA. NUTDNE EXH, FAN GRILLE SIZE AS PER AIR INLET MFR, SPEC'S EXHAUST FAN DETAIL N.T.S. LING #2 CHAIN FROM TOP CORD OF TRUSS TO AHU UNIT W/ DOUBLE NUTTED EYE BOLTS REF. 5/8"PLYWOOD DECK AHU HUNG IN ATTIC DETAIL PROVIDE STEEL SLEEVE AT PENETRATION AND SEAL ENDS WATERTIGHT PROTECT REFRIGERANT LINES UP ALONG WALL WITH LINE COVER AND PAINTED TO MA I CH ARCH I EC I URt LINE COVER SHALL BE 22 GA. SHEET METAL WEATHERPROOF FASTEN TO WALL WITH 1/S"0 CONCRETE NAIL WASHER (2)Ys' PLASTIC COATED STEEL CABLE SECURE TO SLAB W/ S.S. TURNBUCKLES. PER FBCM 301.12 WIND LOAD. FBCB 1301 . I, 1620, ASCE7-10 SECURE CONDENSING UNIT TO � CONCRETE PAD WITH V WIDE GALVANIZED SHEETMETAL STRAPS RATED FOR 110+ MPH HURRICANE FORCE WINDS (TYPICAL) FK SLAB ELEV. _ +0-0' ELEV.1 .60' NVCaD. PROVIDE 3/4' LAG -BOLT TO CONDENSING UNIT CONCRETE BLOCK FILL SLEEVE WITH SILIC SEALANT FOAM CTG FIR n 6 KEEP REFRIGERANT LI HIGH AND TIE TO TRUS MEMBERS STEEL U BAR IMBEADE THE CONCRETE. TIE DOWN CONDENSING UNIT / -NEOPRENE VIBRATION ISOLATORS TO SLAB (TYPICAL OF 4) L A 4 CONCRETE HOUSEKEEPING P D CONDENSING UNIT MOUNTING DETAIL NTS I I I CO I Lr I I I I I I I TUDER VENT I I I L J r-, I L_J I I I I I i rt, h L_J L_J FIJI fol L-J L_J L_J ELECTRICAL PLAN NEW ELECTRICAL "PAVILION" SUB -PANEL 3 100A M.C.B PANEL 120 / 240v 1N 3W(SURFACE) CKT SERVES CB P KIP WM-COND. CKT SERVES CB P KW WDRE-COND. 02 FAN/LIGHT 15 1 .8 # 14 01 WP/GFCI RECEPTACLES 20 1 1.5 # 12 04 GENERAL LIGHTS 15 1 .8 # 14 03 WP/GFCI RECEPTACLES 20 1 1.5 # 12 OB RESTROOM LIGHTS 15 1 .8 # 14 05 WP/GFCI RECEPTACLES 20 1 1.5 # 12 08 POOL LTGS 20 1 1.5 # 12 07 RESTROOM GFCI RECEP 20 1 1.5 # 12 10 POOL PUMP 20 1 1 1.5 1 # 12 09 WATER FALL PUMP 20 1 1.5 # 12 12 POOL FILTER 20 1 1.5 # 12 11 REF 20 1 1.5 # 12 14 JACUZZI PUMP 20 1 1.5 # 12 13 AHU #8 60 1 10.0 # 6 16 08 AC COMPRESSOR 8 45 2 # 8 15 18 10 (NON -CONCURRENT) 17 SPARE -- -- 20 SPARE -- -- 19 SPARE -- -- 8.4 ELECTRICAL NOTES: 1. ALL ELECTRICAL WORK SHALL CONFORM TO THE LATEST REVISION OF THE N.E.C. 2011 AND LOCAL GOVERNING CODES 2. ALL WIRING TO BE COPPER UNLESS OTHERWISE NOTED. 3. ALL MATERIALS, WHERE APPLICABLE, SHALL BE U.L. LABELED 4, ALL OPENINGS REQUIRED BY ELECTRICAL CONTRACTOR TO BE CLOSED TO MATCH FINISH AND FIRE RATED BY ELECTRICAL CONTRACTOR. 5. INSTALLATION HEIGHTS ABOVE FINISH FLOOR UNLESS OTHERWISE NOTED: WALL HUNG TELEPHONE 56' A.F.F. TELEPHONE JACKS 12" A.F.F. LIGHT SWITCHES 48' A.F.F. RECEPTACLES 12" A.F.F. TELEVISION JACKS 12" A.F.F. 6. CO-ORDINATE ALL CONDUIT RUNS AND EQUIPMENT INSTALLATION WITH OTHER TRADES TO AVOID CONFLICTS PRIOR TO FABRICATION, INSTALLATION AND ERECTION. 7. ELECTRICAL CONTRACTOR TO VERIFY ALL HVAC UNIT CONNECTIONS WITH HVAC CONTRACTOR PRIOR TO INSTALLATION. 8. ALL METERS, METER CENTERS AND DISCONNECTS TO BE APPROVED BY FLORIDA POWER AND LIGHT. 9. LOCATION OF ELEC. REC. SHALL COMPLY W/ NEC-210-52 AND RECEPTACLE SPACING SHALL COMPLY WITH NEC 210-72. LIGHTING OUTLETS SHALL COMPLY WITH NEC-210-8 10.ALL NEW CIRCUITS TO BE ARC FAULT PROTECTED NEC 2008 210.12 11. ALL NEW RECEPTICLES TO BE TAMPER RESISTANT NEC 406.11 19.0 TOTAL 27.4 PLUMBING PLAN 1/4"=P-0'° NOTE: PLUMBING FIXTURES, FAUCETS AND FIXTURE FITTINGS TO COMPLY WITH REFERENCED STANDARD AS PER FBC TABLE P2701.1. TO HOUSE CERAMIC TILE BOND COAT REINFORCED WALL MORTAR BED OLID BACKING 0 CERAMIC TILE INTEGRATED DRAIN BONDED FLANGE CRUSHED TILE SLOPED REINFORCED FLOOR OR STONE AROUND MORTAR BED 1-1 3/4' THICK WEEP HOLES SHOWER DETAIL N.T.S. LJ \ ISOMETRIC PLAN 2• VrRjl PAVILION POOL LAV BATH A rj'j'$1ESE PLANS AND ALL PROPOSED WOR -- "UBJECTTOANYCORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO rnMpIywlT61 et AGSI Ir.As�eg Cyppg, PLUMBING} NOTES 1. THE ENGINEER CERTIFIES TO THE BEST OF HIS KNOWLEDGE, ALL WORK DEPICTED IS IN ACCORDANCE WITH THE FLORIDA BUILDING CODE, INSTALLATION SHALL COMPLY WITH STANDARDS THEREIN. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL EQUIPMENT DESIGN REQUIREMENTS (I.E VOLTAGE, WATER, DRAINS, GAS CONNECTIONS, ETC.) WHEN REQUIRED FOR THE CORRECT/APPROVED OPERATION, THE EQUIPMENT SHALL BE FURNISHED WITH ALL NECCESSARY ACCESSORIES NETHER CONSIDERED OPTIONAL OR STANDARD BY THE MANUFACTURER EQUIPMENT SHALL NOT BE ORDERED BASED ON MANUFACTURERS' MODEL NUMBERS. 3. ALL MATERIALS AND EQUIPMENT SHALL BE NEW, FREE FROM DEFECTS ��-'- AND WITH FACTORY WARRANTY, PRODUCTS SHALL BEAR RESPECTIVE ri A.S.T.M. STANDARD LABELS AND INSTALLED AS PER LISTING UNDER SUCH. r=. 1 4. INSTALL SANITARY LINES AS TO DRAIN WITH SLOPES OF NOT LESS THAN 1/8' PER FOOT FOR 3- SND ABOVE AND 1/4- PER FOOT FOR 2-. �. W 5. INSTALL PIPING AND EQUIPMENT ALLOWING ADECUATE ACCES FOR ° ,aJ SERVICE TO VALVES AND EQUIPMENT OF OTHER TRADES, PROVIDE U.L LISTED ACCESS PANELS IN WALLS AND CEILING WHERE P1 ACCESS IS REQUIRED. ?••. 6. INSTALL CLEAN -OUTS AS INDICATED ON DRAWINGS AND AT EVERY m 75 FEET, BASES OF STACKS AND CHANGE OF DIRECTION. v c: w ca }Gq u 7. SANITARY, VENT AND RAIN WATER LEADER PIPING SHALL BE SCHEDULE 40 ` C PVC SOIL PIPE WITH DRAINAGE TYPE FITTING, SOLVENT WELDED. PRIME FITTINGS AND PIPE ENDS PRIOR TO WELDING, EXCEPTION: IN AIR I w 'J CONDITIONING PLENUMS, i.e. MECHANICAL ROOMS, CAST IRON PIPING ;;. I"..�, +' SHALL BE USED. 8. DOMESTIC WATER PIPE SHALL BE TYPE L ABOVE GROUND AND TYPE K BELOW GROUND. SOLDER FITTINGS USING LEAD-FREE SOLDER, AVOID JOINTS BELOW SLABS OR INSIDE WALLS WHENEVER POSSIBLE. 9. PROVIDE EXPANSION AIR CHAMBERS OF 20 PIPE DIAMETERS BUT NOT LESS THAN 12". INSTALL AT EACH FIXTURE, GROUP OF FIXTURES, RISERS AND END OF SUPPLY LINES. 10. ISOLATE COPPER PIPING FROM DISSIMILAR METAL, MASONRY OR CONCRETE WITH FOAM PLASTIC, FIRE RETARDANT INSULATION OR SIMILAR METHODS APPROVED BY LOCAL JURISDICTION. 11. PROVIDE PIPE SLEEVES FOR ALL COUNG, FLOORS OR WALL PENETRATIONS PACK WITH FIRE RETARDANT CAULKING IN CONFORMANCE TO U.L �'�`�ro, SPECIFICATIONS. 12. PLUMBING FIXTURES SHALL BE FIRST GRADE NITROUS CHINA CONFORMINGTO ANSI STANDARDS, FURNISH TRAPS, VALVES AND ALL TRIM,COMPLY WITH ALL CODES AND ORDINANCES. A,ERICAN STANDARD OR EQUAL + WATER & SANITARY PIPING MATERIAL MATERIAL NOTE: WATER SERVICE PIPING CHLORINATED POLYVINYL CHLORIDE (CPVC) PER FBC 2010 TABLE 605.3 WATER DISTRIBUTION PIPING COPPER PER FBC 2010 TABLE 605.4 SANITARY & VENT PIPES POLYVINYL CHLORIDE (PVC) PER FBC 2010 T BLE 702.1 TABLE 702.2. T 2tf TABLE 702.4 (,_. REVISIONS BY CL1ENr CHAINIM CY W-24-17 AS BEAL73 Cv 12-2147 F� R� v I C) 0O 0< A o ! gad no a ON N � E+ aw0 11 Jill DRAWN BY: CARLOS VIIACA 1000 S DIXIE HWY. WEST POMPANO BEACH FLA. 33060 PHONE:561- 445- 9661 EMAIL: carlosvllaca2®Gmatl.com DATE 1-lo-n SCALE: PROJECT Li r F— C� ❑ d L!i N Lf) r 0 N O r— V I LLLJ ry O O O J O a o LOT BOUNDARY LANDSCAPE AREAS NATIVE VEGETATION FT = U SLOPE i W I POOL L-i x 102 un Lij U UGH IN FL O 4' ` � III 1 SLOPE; SLOPE .>a M Ml iE\J,l`,�y 1 \\\\\p , IN 0 z„ \ mo 1 4" 'F T \ s SLOPE SUMMER KITCHEN i z ROUGH 'FIN. FL 0 N 23'-0" ON yL 24.0' NAVD 0 ROUGH FIN. FL Us ti O N'AVC Ya LANDSCAPE AREA OR SOD- 34'-6" 7, 0- 12 ——•—•—•—.—.—.—.—.—•—•—•—•—•—•—.f_.—.—•—•—•—•—•—•—•—.—.—.—.—. WATER FALL POOL DECK (BY OTHERS) SITE PLAN SCALE: 1 /8" = 1 ' — 0 " liO4-040.; ST, LUCIF COUNTY E'I_tL T-NC DIMS'" REVIEWED FOR COxipLL4Ng R.FVIEW'ED BY DATE PLANS ANT► PERMIT NSUST BE KEP ON JOB OR NO INSPECTION WILL BE ?MADE. LANDSCAPE AREA OR SOD NORTH KEY PLAN N TS m FINNVOLD ARCHITECTURE, INC. POOL, POOL DECK & POOL AVI7F77800O N, FEDERAL HWY. SUITE 118 COVERED AREA = 1,976 S.F.30CARATON, FL 33487 P. 561 306 4286 F. 561 953 5210 AIR CONDITION SPACE = 1,260 S.F.LICENSE # A A 26002586 POOL AND DECK AREA = 6,222 S.F. ALLDESIGNSAND DETAILS INDICATED OR REPRESENTEDBY THIS DRAWING ARE FOR THE USEON AND IN CONJUNCTION WITH THE SPECIFIED PROJECT. THIS IS THE PROPERTY OF FINNVOLD ARCHITECTURE, INC. AND SHALL NOT BE USED OR REPRODUCED WHOLE OR IN PART WITH -OUT HATCHED AREA WRITTEN PERMISSION OR BELIABLE FORTHEFULLEST LEGAL RECOURSE. THE CONTRACTOR SHALL VERIFY DENOTES POOL ALL EXISTING CONDITIONS AND DIMENSIONS AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES _-- PAVILION O DECK PRIOR TO THE EXECUTION OF THE WORK. v, ` 1 a nCq YYYJ k .. I NEW RESIDENCE FOR MR. CESPEDES PARCEL ID w 8 —T.5P 3224-111-0002-000-2 SITE PLAN KEY NOTES C 24 CANAL RD SAINT LUCIE COUNTY 101 CONTRACTOR TO COORDINATE LOCATION/CONNECTION OF TELEPHONE, CABLE AND ELECTRICAL SERVICE WITH ST LUCIE COUNTY UTILITIES DEPARTMENT. 1p2 PAVER DRIVEWAY AND PATHWAYS. REFER TO DETAIL 5/AO.07 103 FUTURE GENERATOR LOCATION, 10'-0" MIN. FROM HOUSE, 10 —0 MIN. FROM ANY INTAKE OPENING. REFER TO 7/AO.07 FOR PAD DETAIL, COORDINATE FOR FUTURE TRANSFER SWITCH WITH ELECTRICAL PANELS PROVIDED 2.27.17 104 TANK —LESS GAS WATER HEATERS 1701 105 500 GAL. UNDERGROUND PROPANE TANK. SIZE & HOLE DIMENSIONS TO BE CONFIRMED WITH GAS COMPANY (PERMIT BY OTHERS) 106 DENOTES NEW CONCRETE PADS. SEE DETAIL 7/AO.07 " , 107 1 0 WATER CONNECTION, 100 MIN. FROM SEPTIC. CONTRACTOR REVISIONS TO COORD. W/UTILITIES DEPT., MEP, & CIVIL DWGS. 108 NEW SEPTIC SYSTEM & DRAIN FIELD LOCATION. CONTRACTOR TO PERMIT SET COORDINATE WITH UTILITIES, CIVIL AND MEP DRAWINGS 4.26.17 109 ELECTRICAL METER/ OR SUB PANEL, REFER TO ELECTRICAL REVISION 10.2.17 DRAWINGS FOR DETAILS. COORD. W FPL. 0 DENOTES NEW UNDERGROUND ELECTRIC. OWNER REQUESTED 110 CONTRACTOR TO COORDINATE WITH FPL REVISION 111 DENOTES POOL EQUIPMENT. CONTRACTOR TO COORDINATE 112 CRUSHED SHELL ROCK PATHS/PARKING. COORD. W OWNER. 113 PROPOSED LIFT STATION. COORDINATE W CIVIL DRAWINGS 114 PROPOSED WELL LOCATIONS. COORDINATE WITH CIVIL DRAWINGS 115 STUB —OUT FOR FUTURE CABLE INSTALLATION (CONTRACTOR TO COORDINATE LOCATION WITH OWNER) 116 PROVIDE WATER SOFTENER AND FILTERING SYSTEM AS REQUIRED 117 DENOTES COMPOSTE STATION AT STABLES/MANURE PIT 118 ALUM. GATE (STYLE TO SELECTED BY OWNER) CONSULTANTS 119 4'6" H. ALUM. FENCE (STYLE TO SELECTED BY OWNER) 120 24"x24"x6'0 HI. CONCRETE BLOCK PIERS, SEE DETAIL SHEET A0.07 12'k12"x5'0 HI. CONC. BLOCK PIERS PLACED MIN. 12" FROM 121 PROPERTY LINE AND FOOTINGS MUST BE WHOLLY ON THE PROPERTY. SEE GATE ELEV. DETAIL SHEET AO.07 �0 O 4'6"'H (2' MESH) ALUMINUM CHAIN LINK FENCE BY OTHERS, y"1 •-�tf'rl,. 122 CONTRACTOR TO COORDINATE WITH OWNER, PROVIDE SHRUBS PLANTED AT 24" ON CENTER And MIN. 30" FROM FENCE. SEE L'o 7Q17 LANDSCAPE PLANS. 3 RAIL HORSE BOARD WOOD FENCE BY OTHERS CONTRACTOR < <'% MAG 123 uciu' ounty, FL TO COORDINATE WITH OWNER. RAMM HORSE FENCE AND STALLS (800)434.8456 SITE PLAN 124 PREFABRICATED D CONTRACTOR TO COORDINATELWITH OWNER. STALLS HORSE HFENCE AND STALLS (800)434.8456 4-A 1.00 N uJ 0 Lu 11 Lu U I r- O r J LJJ 0 LJJ rvlo W w Lu Lu 2 Q 0 O Z_ LL X Q 0 L 0 / " L v) N N U PARTITION LEGEND TYP. EXTERIOR WALL - 5/8" STUCCO ON 8" CONC. BLOCK ON BOTH SIDES. PAINT BOTH SIDES EXISTING WALL TO REMAIN A j� DENOTES STEEL COLUMN WITH DECORATIVE WRAP (TYP). • MATCH MAIN HOUSE COLUMNS. COORDINATE WITH, STRUCTURAL DRAWINGS / v SYMBOI-alEGEND ®X NEW DOOR SYMBOL X�XX NEW WINDOW SYMBOL Y -r ELEVATION MARK �1 a z INTERIOR ELEVATION MARK 3 X ELEVATION TARGET SECTION MARK KEYNOTES O36" HT, 24' DEEP BASE CABINETS WIDTHS VARY. SEE PLANS O24"08" ATTIC ACCESS W/PULLDOWN LADDER, PROVIDE 100 S.F. AREA OF 5/8" PLYWOOD AROUND ATTIC ACCESS FOR STORAGE SUPPORT O 12" DEEP UPPER CABINETS DO SINK WITH DISPOSAL O FULL HT TILE BACKSPLASH, TYPICAL OF TV & OUTLET & CABLE CONNECTION 05'-0" A.F.F. COORDINATE LOCATION IN FIELD WITH HOMEOWNER. OBUILT-IN BAR. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR REVIEW AND APPROVAL O OUTDOOR SHOWER OINSTALL TANKLESS WATER HEATER WITH THERMOSTATIC CONTROL VALVES FOR HOT WATER AS REQUIRED. O TOILET PAPER HOLDER (D TOWEL BAR 8ML BEVELED MIRROR ICE MAKER CN) UC REF. FLOOR PLAN NOTES 1. GLAZING WITHIN 36' HORIZONTALLY AND 60" VERTICALLY OF SHOWERS/TUBS SHALL BE CAT. II SAFETY GLASS PER 2405.2 FBC. 2. GLAZING ON EXT. DOORS AND SIDELIGHTS SHALL BE CAT. II SAFETY GLASS AS PER 2411.3.1.3. FBC. 3. SHOWERS/TUBS SHALL HAVE FLOORS AND WALLS TO 70" OF NON -ABSORBENT MATERIALS AS PER 1204.3 FBC. 4. WALL HUNG FIXTURES AND CABINETS SHALL BE SUPPORTED AS PER 2510.5 FBC. 20 CA MTL STUDS 0 16" O.C. W/ HORIZ. REINF. 5. BUILDING SWILL HAVE PRE -CONSTRUCTION TREATMENT PROTECTION AGAINST TERMITES AS PER 1816.1.7 FBC. 6. MIN. CEILING HEIGHT SHALL BE 7'-0" AS PER 1203.2.6 FBC. 7. PROVIDE GROUTED CELL OR COLUMN AT BEARING POINT OF EACH GIRDER TRUSS. B. ALL EGRESS WINDOWS TO COMPLY WITH F.B.C. AN OUTSIDE WINDOW OR DOOR OPERABLE FROM THE INSIDE WITHOUT THE USE OF TOOLS AND PROVIDING A CLEAR OPENING OF NOT LESS THAN 20" WIDE X 24" HIGH AND 5.7 SO. FT. THE BOTTOM OF THE OPENING SHALL NOT BE MORE THAN 44' A8V. THE FLOOR. 9. EVERY CLOSET DOOR LATCH SHALL BE SUCH THAT CHILDREN CAN OPEN THE DOOR FROM THE INSIDE OF THE CLOSET. 10. EVERY BATHROOM DOOR LATCH SHALL BE DESIGNED TO PERMIT THE OPENING OF THE LOCKED DOOR FROM THE OUTSIDE IN AN EMERGENCY. 11. EVERY SLEEPING ROOM SHALL HAVE AN EMERGENCY ESCAPE AND RESCUE OPENING AT A MAXIMUM HEIGHT OF 44" TO SILL. FBC R310.1 ALSO READ NOTE #8 THIS SHEET. 12. OPERABLE WINDOWS WITH A SILL LESS THAN 36" A.F.F.,WHERE THE FLOOR HAS A DROP OFF MORE THAN 4'-0", REQUIRE SAFEGUARDS AT NOT LESS THAN 42" IN HEIGHT (CHECK FOR REQUIRED ESCAPE OPENING DIMENSIONS WHEN THIS CONDITION) FBC 2411.4.1 13. ALL PRE -FABRICATED BUILDING ELEMENTS TO HAVE ENGINEERED SHOP DWGS. SUBMITTED TO THE VILLAGE OF PINECREST BLDG. DEPT. FOR REVIEW AND APPROVAL PRIOR TO FABRICATION & INSTALLATION. NOTES TO CONTRACTOR 1. GLAZING IN WINDOWS AND DOORS, FIXED GLASS, ETC. SHALL BE IMPACT RESISTANT OR COMPLY SFBCR SECTION 4410.4 2. IF STORM SHUTTERS ARE USED, THEY SHALL BE APPROVED BY PRODUCT CONTROL SECTION AND SHALL BEAR THE NAME OF THE COMPANY GRAVED IN EVERY SECTION OF THE SYSTEM. (COMPLY WITH SECTION 4410.4 SFBCR 3. WHEN OUTLETS ARE IN BACK —SPLASH, COORDINATE COLOR TO MATCH, TYP. 4. ALL CABINET BOXES TO BE CONSTRUCTED OF PLYWOOD. NO PARTICLE BOARD CABINET BOXES. •. - �litTiTtillm ELDORADO STONE'VENEER REBAR (WHERE OCCURS) MORTAR SETTING BED MORTAR JOINT CMU WALL DENOTES RETRACTABLE SCREENS. S HW �\ CONTRACTOR TO /Jr COORDINATE WITH OWNER ♦ 45'-4" 1 -------------- -------------------- PORCH STONE 0 m I D708 v \ \ \ N 0 I m N O I / / I i / / I Dtm a I f m m -------- - - - - -I -------- 14'-9" S" 14 T / DENOTES EXIST. N STEEL COL. ' POOL PAVILION STONE / 0'-0" 2s.0' NAw ROUGH fIN. FL / DENOTES VAULTED \ CEILING ABOVE \\ o \7 I \ \ 29'-1 NOTE TO CONTRACTOR: VERIFY EXISTING COLUMN LOCATIONS AND COORDINATE WITH DOOR SUPPLIER PRIOR ORDERING DOORS 1s'-1' otos Dtoa 15-1 PORCH STONE 44'-B• FLOOR PLAN SCALE: 3/16" = l'-0" DENOTES RETRACTABLE SCREENS. CONTRACTOR TO COORDINATE WITH OWNER --- _J ------------ - - - - -- -J DENOTES EXTERIOR OUTDOOR SHOWER 0 a a❑ a❑ IMPACT NEXT DR CO.) ED OUTSWING DOOR OUTLINE �m lul ■ 10'-8'pLG HT� ■ POOL PAVILION VAULTED CEILINGS ®k J ■ ■ .1--.,BATH �w y U ■ 10'-6"CLG HTFE r. VAULTED VAULTED CErG ® ® CEILING • (1 ■ ■ ■ A GAME RO CL ■ STONE OOR I � o cD ■ h h Y J Y I >� ! I ■ I� ■ ® R ------------ 1�$ L H II GYP. BID � ■ I I BAR ; II I I, ' 1 I GYP. B� H i I I I ■ ■■ ■----__F■ v U IFOR REFLECTED CEILING PLAN SCALE: ^3/16" =/I �0" is ■ FINNVOLD ARCHITECTURE, INC. I\ 1 \® 4—" • I \ I \\ REMOVE EXISTING \\ BLOCK WALL AS • \ SHOWN -- --- \ I j \\ REMOVE EXISTING I \\ ROOF PLYWOOD AS • i \ NEEDED TO PLACE \\\ NEW TRUSSES AND EXTEND ROOF HIP X, --- -------------------- ■ ■ I \ I / I / \ I \ REMOVE EXISTING STEEL \\ I / COLUMN AND BEAM ABOVE. SHORE UP AS REQUIRED. \\ 1 / REFER TO STRUCTURAL DRAWINGS FOR DETAILS ■ \� 1 ------------------ IML— ------------------- I / � 15='= 4._D.. 1 \ IL— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — :2:_6.. — -------� 1 NORTI- DEMOLITION PLAN SCALE: 3/16" = l'-0" ROOF SCHEDULE PRODUCT APPROVAL MANUFACTURER DESCRIPTION COLOR DYNAMIC METALS, LLC DYNAMIC 1-1/2" MECH FL 21082 RO II 3201 SE DOMINICA TER. SEAM .032 ALUM. ROOF BRONZE FINISH DYNAMIC METALS STURT, FL 34997 POLYGLASS USA INC POLYGLASS PLYSTICK NOA 15-0410.04 1111 W NEWPORT CTR DR UNDERLAYMENT DEERFIELKD BCH, FL An I\ - — - - IN I \\III DENOTES 6" ALUM. I I \ GUTTER I I DENOTES STANDING SEAM \\ METAL ROOF. BRONZE FINISH ■ ' I � I I w / a 1n --------------- --- o--- - - - - - - - - - - ■ - 4 AI SLOPE - • o — J (n 1 — I • I ' I I - -- ---F -- -- --- a ■ ■ ■ SLOE - i i i I ROOF PLAN SCALE: 3/16" = l'-0" ■ 0 8000 N. FEDERAL HWY. SUITE 118 BOCA RATON, FL 3 3 4 8 7 P. 561 306 4286 F. 561 953 5210 LICENSE # A A 26002586 ALL DESIGNS AND DETAILS INDICATED OR REPRESENTED BY THIS DRAWING ARE FOR THE USE ON AND IN CONJUNCTION WITH THE SPECIFIED PROJECT. THIS IS THE PROPERTY OF FINNVOLD ARCHITECTURE, INC. AND SHALL NOT BE USED OR REPRODUCED WHOLE OR IN PART WRHF OUT WRITTEN PERMISSION OR BE LIABLE FOR THE FULLEST LEGAL RECOURSE. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES PRIOR TO THE EXECUTION OF THE WORK. NEW RESIDENCE FOR MR. CESPEDES PARCEL ID 3224-111-0002-000-2 C-24 CANAL RD SAINT LUCIE COUNTY 2.27.17 1701 REVISIONS PERMIT SET 4.26.17 Q REVISION 10.2.17 OWNER REQUESTED REVISION CONSULTANTS POOL dPAVILION FLOOR PLAN AND •'T�' � m1:.9< rs\Addana\Dropbox\D-FINNVOLDARCHITECTURE\PROJECTS\RESIDENTIAL\1701-YCESPEDES\CD\1701-04-POOL\1701-04-POOL-REV3dwq.dwq, 10/12/20172:56:31 PM, DWGToPDF.pc3 45' 4, REINFORCED MASONRY WALL NOTES 37'-4„ NEW NEW F 48 EXISTING 24 MF-24 MF— 0-�pp— 1--------- EF�48 -- �— p 1— r-XISTINr, TYPICAL 4" SLAB ON GRADE W/6x6, W1.4xW1.4 W.W.M. ' 1 —.—. —. —. —.—. —. —u —.— ---------------- . 10 I-TJ L_ I_J TE-12 L----J I I 1 4" STE j 15'-r' 15'-11. 1 j C1 48" 0. VIF MF 9 1 I 1 # 5 X 2' DOWEL 24' O.C. I yE'4 I 6' EMBED WITH 2 PART EPDXY C1 48" O.C} 1 1 a MF-24 X � EXIONG PQURED IF �_12 4" SLAB ON GRADE W/6x6, W1.4xvh.4 W.W.M. I 5'-10" 1 I I L---- I MF-24 C TE 12 - T N o N 11 S_ 1 L---r rH c I I I I I I I I I I I 14-40" EXISDNG C1 48" O.0 I I F 48 # 5 X 2' DOWEL 24" O.E. EXISTING rn • II 6" EMBED WITH 2 PARTIEPDXY FT-12 L LJI NE I I---------- r- I_ -------j--— — — — — — — — — — — — — — — -- r --- — — F 4 I_ T, I _ - - - - - - - - - - _ I------�- 1 IEXIST. COLUMN TO REM 2 -------------------- I MF-24 S-1 _ J I I 30'-10" 6'-6" 1 87'-4" NEW MF-24 I —E TREATMENT REQUIRED i 4� SLAB ON GRADE W/fix6,I W1.4xWi.4 Cl 48" 0. O 4 MF-24 TE 12 I REW E I 1 MfMF-24 CMF-24 era" 1 U N I - I -------_-TSr1„ -------------------- MF I I I 4" STEP. 1 1 L _ J L -�—OJ C1 48" D.C. j F 48 NEW j F 48 0'IT ii 4" SLAB ON GRADE W/6x6, W1.401.4 W.W.M. rJ_I _1 1---------------------- ---------I +---------------------------- I I —L---------------- - NEW , IL- OJ F 48 L_ J 45' 1 NEW TE-12 I I ®I 1fEW F 48 FOUNDATION PLAN me = r-go r I = -lrs1u v SIMPSON HTSM20 STRAP 10- fOD X 1 1/� 11-10D X 1 1/2 TO TRUSS 1TT1T7gqyy5TLBS PLIF 1 10— 1OD X 1 1/2" TO WOOD OR Simpson Stronq-Tie HETA 0 4— 1'4" X 1 3/4" TAPCONS TO CONIC BEAM - ALL 3/4" DIAM. THRU BOLTS TO BE ASTM A325. - ALL 1[4" STEEL PLATES TO BE ASTM A36. - ALL VECIFIED MATERIALS ABOVE TO BE EQUAL OR BETTER. - 1/4" FILLET WELD ALL AROUND FOR ALL PLATE CONNECTIONS. - ALL BOLT HOLES TO BE 7/8" DIAM. MFOR g�3/4" DIAM. BOLTS. —b� A S. O M'73TAI IFRU BOLT IN LOAD PERPENDICULAR TO GRAIN — 1,330 LBS LOAD PARALLEL TO GRAIN = 2,550 LBS — WITH SHORT DURATION LOAD FACTOR CD=1.33 USING 1.3 FACTOR,1,330 LBS x 1.3 = 1,729 LBS/BOLT STEEL COLUMN DETAIL }3/4" WE 1/4. 1N. STEEL r r 0 0 ° ° 2-3/4' B0.B 5. s r 2" CORNER SADDLE 4' fNllf 3/4 BgSE PLATE F SIMPSON VTCR VALLEY CLIP NEW VALLEY TRUSS UPLIFT = 370# EXISTING PL 3-3/4" N�f 1/i 1X STEEL r � r r r r ° 0 0 4-3/C BU OF. exTs -10D TO VALLEY 4- 10D TOE NAILED TO EXISTING TRUSS 6-6" �'.1 B 3 I `IF 1 �®lm�.�.�■Il./�I ,Li���l�l��''�����iltiiil,li��p��lEf:i �11�1 �1 in ■� II ® in ®ll� ❑E NoffE IE Q LL�LL n1/4" THK. STEEL 2- 3/4" BOLTS 6" LG TO TIE BEAM 5 1/2• TO CONCRETE 2- 1/2" BOLTS FOR UPLIFT 5 Ex G NEW B SUW 2 S-1 DOWEL DETAIL w/ (3) #5'S C DOUBLE MESH @ FOOTER r :4 MESH W/ (3) #5'S CONT. 24" C(2)FGTR UPLIFT -9400 18-SDS 1/4"x3" (PER ANCHOR) 4-1/2X5 TITEN HD ANCHOR Simpson Strong- DOUBLE FGTR Cd � e . 24" FRAMING PLAN -Me = r-c d MESH ` - -- ''E-- 145 CONT. 3" MIN. COVER 12• CSHOWER RECESS _ THICKENED EDGE 1. HOLLOW LOAD —BEARING MASONRY UNITS SHALL CONFORM TO ASTM C-90, TYPE I, GRADE N, SQUARE END, WITH A MINIMUM AVERAGE COMPRESSIVE STRENGTH ON NET AREA OF f'm=2,000 (PSI). CONSTRUCTION SHALL BE IN ACCORDANCE WITH ACI 530.1 SPECIFICATIONS. 2. QUALITY ASSURANCE INSPECTIONS ARE REQUIRED FOR ALL REINFORCED MASONRY CONSTRUCTION. THE INSPECTOR SHALL INSPECT THE FOLLOWING: A. PLACING OF THE REBARS IN THE CELLS (POSITION IN THE CELL, LAPPING AND SPLICES, BAR SUPPORT AT 10 FT. HEIGHTS). B. VERIFY CLEANLINESS OF THE CELLS TO BE GROUTED. INSPECTION HOLES AND THE BOTTOM OF THE POUR AND MORTAR PROJECTING INTO CELLS TO BE GROUTED. C. OBSERVE AND BE PRESENT DURING THE PLACING OF THE GROUT OR CONCRETE INTO THE VERTICAL CELLS. D. THE ABOVE APPLIES FOR MASONRY BEAMS AND BOND BEAM INSPECTION AS WELL. 3. MORTAR SHALL CONFORM TO ASTM C-270, TYPE "M". 4. LAY ALL MASONRY WITH FULL FACE HEAD JOINTS AND WITH FACE SHELL MORTAR BEDDING. 5. MASONRY ANCHORAGE TO SUPERSTRUCTURE SHALL BE PROVIDED IN ACCORDANCE WITH STRUCTURAL DRAWINGS AND DETAILS. 6. THE USE OF ADMIXTURES SHALL NOT BE PERMITTED WITHOUT PRIOR REVIEW OF THE ENGINEER. 7. VERTICAL REINFORCING: (A) ASTM A-615 PER REINFORCING SECTION. (B) WHEN A FOUNDATION DOWEL DOES NOT LINE UP WITH A VERTICAL CORE IT SHALL NOT BE SLOPED MORE THAN ONE HORIZONTAL INCH TO SIX INCHES VERTICAL FOR ALIGNMENT, EVEN THOUGH IT IS IN A CELL ADJACENT TO THE VERTICAL WALL REINFORCING. (C) VERTICAL REINFORCING STEEL SHALL BE PLACED CENTERED IN THE CELL. LAP 48 BAR —DIAMETERS. PROVIDE BAR SPACERS AS REQUIRED TO MAINTAIN REINFORCING SECURED IN POSITION (AT 10 FT. VERTICAL SPACING). (D) VERTICAL REINFORCEMENT SHALL BE PROVIDED AT EACH SIDE OF OPENINGS IN WALL, AT WALL INTERSECTIONS, CORNERS AND ENDS. THIS REINFORCING SHALL BE THE SAME SIZE AS THE SCHEDULED WALL REINFORCING FOR THE PARTICULAR WALL BUT NEVER LESS THAN A #5 REBAR. SPECIAL CARE SHALL BE TAKEN TO INSURE THAT CELLS TO BE GROUTED LINE UP PROPERLY AND ARE CLEAN OF EXCESS MORTAR. (E) ALL VERTICAL REINFORCING SHALL BE HOOKED INTO THE BOND BEAMS AT THE NON —CONTINUOUS END OF THE REBARS. (F) PROVIDE INSPECTION HOLES AT THE BOTTOM OF EACH REINFORCED MASONRY CELL, AS REQUIRED FOR LIFTS HIGHER THAN 4 FT. 8. HORIZONTAL REINFORCING: PROVIDE GALVANIZED #9 GAGE, LADDER TYPE HORIZONTAL JOINT REINFORCING EVERY SECOND BLOCK COURSE (1'-4" O.C. VERTICALLY) LAPPED 7-1/2". PROVIDE SPECIAL HORIZONTAL REINFORCING AT "T" AND "L" INTERSECTION. ANCHOR TO COLUMNS WITH MINIMUM 4" EXTENSION INTO AREA OF POUR. e CONCRETE FOUNDATION SCHEDULE MARK SIZE REINFORCEMENT BOTT TOP MIDDLE REMARKS MF-24 24"W X16"D CONT. CONIC. FTG. 2 #5 1 #5 SEE DETAIL 12"x12" TE-12 CONCRETE CONT.FOOTING 1 #5 SEE DETAIL F 48 48" X 48"X 24" DP 2-ROWS 2-ROWS CONCRETE FOOTING 5#5 5#5 SEE DETAIL F 56 56" X 564X 24" DP 2-ROWS 2-ROWS SEE DETAIL CONCRETE COLUMN SCHEDULE MARK SIZE REINFORCEMENT HOOPS REMARKS D C 1 8"x 8" 1# 5 48" D.C. FILLED CELL NONE 3000 PSI ® 8"x 12" CONC. COLUMN 4 5 # # 3 AT 12" O.C. 3000 PSI ■ CONC. COLUMN C 4 # 5 # 3 AT 12" D.C. 3000 PSI ® c� 3.5" X 3.5" X 1/4" STEEL COLUMN SEE STEEL COLUMN DETAIL ® 6" X 6" X 3/8" STEEL COLUMN SEE STEEL COLUMN DETAIL CONCRETE BEAM SCHEDULE MARK SIZE REINFORCEMENT REMARK BOTT TOP MIDDLE NOTES L-1 8"x 8" UNTEL 1 #5 VARIES SEE ELEV. VARIES L-2 UNTIL" 1 #5 1 #5 SEE ELEV. BB-1 BOND BEAM 1 #5 1 #5 VARIES SEE ELEV. B-1 8"x 24" #3 STIRRUPS VARIES CONC. BM. 2 #6 2 #6 2 #6 ® 6" O.C. SEE ELEV. B-3 8"x 18" CONIC. BM. 2 #5 2 # 5 2 6 # #3 STIRRUPS VARIES ® 6" O.C. SEE ELEV. ADD # 5 REBAR FOR VERY ADDITIONAL 6" IN DEPTH OF BEAM PAD REBAR EDGE i STEELCOLUMN(SEE PLAN) BARS -ALWAYS, ANCHOR BOLTS REMAIN - SPACE OTHERS EQUALLY SEE MANUFACTURES SPECS GRADE o X a N � O s I, SEE PLAN EXERIOR PAD AT.COLUMN fi ' •.. 1 .I�3'�ii.�L7F'eY:iii��J '�. h i^lip �N'�e�v7.��ra x Y' � 1' + hM114# l 3 r u • • 1 L Lc 111CONCRETE b REVISIONS BY l f� FL 660 N N7 O Pq F- rn w a Z 4 F X /•� O �ri,ll O IQi 0. J wJ Q.I w m ONO J U J z w It tp2�0 w 0- DRAWN BY: CARLOS VR ACA 1000 S DIXIE HWY. WEST POMPANO BEACH FLA. 33060 PHONE:561- 445- 9661 EMAIL: cor1osvilaca20GmaII.com DATE 1-10-17 SCALE: Y16 = r-0" PROJECT: NAIX= CHURCEML CONC. LINTEL 'CASTCRETE' SEE LINTEL SCHEDULE TYP. BOND BEAM COL STL (SEE WALL S 4" MIN. (1) # 5 MIM. MEIL FORM & POUR SOLID — 6" DP. ('ryp. EA SH.L ). I i i I i I I II I `L.VPI I.. D1R1. rl ' i -------------- BOTTOM OF F99-IME------------L- ----------- AD) # 6 FOR OP GS GREATER THAN 4'_4" TYP. WINDOW/ M. 0. OPEN'G IN BLK. W CONC. LINTEL 'CASTCRETE' TYP .DOOR/ M. 0. OPEN'G IN BLK. WALL 1/4„ 4„ 1 .. e e m 1/4" W/2-5/8" A.B. STEEL COL TO CONCRETE BEAM m strap (SEE STUCCO SC REINF. (SEE BI CELLS SOLID FOUNDATION EL. 100'-0" GRADE A < d r^ a a SEE SCH. WALL SECTION W/ 2' ROOF WIND ZONE DIAGRAM ZONE 1 : -38.33 PSF ZONE 2 : -64.21 PSF ZONE 3 : -64.21 PSF A -ZONE 4.45 FEET WIND ZONE PRESSURE DIAGRAM REINFORCED FILLED CELL SEE PLAN FOR SIZE AND SPACING. 9 GAUGE HORIZONT, REINFORCEMENT EVERY OTHER COUR 8" x 8" x 16" ONCRETE (LADDER TYPE) MASONRY UNITS BLOCK REINFORCEMENT Mr'e S':% REINF, W 1# SEE P 4 ® 6'-0" O,C, WOOD BASE. — EXP. JOINT SMOOTH 4" CONC. SLAB W/BxB-10/10 MESH ON 4 MIL VISQUEEN VAPOR BARRIER DOUBLE MESH & FOOTER 2COMPACTED TREATED FILL OVERHANG 11 5' ZONE PLAN 5 8" CDX A A RATED �PERPENDICULAR TO I `r�•- TRUSSES 2 X FASCIA WITH 3 —16D � �y J ROOF TRUSSES 1 24" O.C. `\ L 2X 4BLK 24"O.0 4"-0" AT GABLE ENDS ROOF SHEATHING SHEATHING SCHEDULE LOCATION PANEL FASTENERS SPACING /ZONE 5/8" CDX 6" O/C EDGES /ZONE 4 WALLS APA RATED 8d 4" O/C EDGES / ring shank ZONE 5 5/8 CDX 8d 6" O/C EDGES ZONE 1 ROOF APA RAT/ZONE 2 RATED ring shank 4" O/C EDGES / ZONE 3 PLYWOOD ROOF DECKING AND DIAPHRAGM A. SHALL BE 19/32" MINIMUM THICKNESS, "CDX" TYPE AND SHALL BE CONTINUOUS OVER THREE OR MORE SPANS, NTH FACE GRAIN PERPENDICULAR TO THE SUPPORTS. B. CONNECT PLYWOOD ROOF DIAPHRAGM TO STRUCTURE WITH 8d RING SHANK. NAILS, 2x4 BTM. CHORD BRACING 72" O/C MAX., SECURED W/ (2) 10d COMMON NAILS AT EACH CHORD INTERSECTION, TYP. 2x4 DIAGONAL BjH. CHORD BRACING, SEE PLIAN FOR LOCATION BTM. CHORD OF WOOD ROOF TRUSSES BOTTOM CHORD BRACING NTS :A.)#5 TOP & BOTTOM : BEAM DETAIL) TYPICAL X/BRAC 9 GA HORIZONTAL REINFORCEMENTN # 5 DOWN BAR 36" ABOVE p SLAB . 12" HOOK AT FOOTING 8" X 8" X 16' li QK OUT CORNER DETAIL 2x4 #2 SOUTHERN YELLOW PINE CROSS BRACING MEMBERS FASTENED TO TRUSSES W/4-16d NAILS EACH END (REFER TO TRUSS NOTES, TRUSS LAYOUT AND NOTE BELOW FOR LOCATION) 2x4 CONT. LATERAL WOOD BRACING NAILED TO BOTTOM CHORD MAXIMUM 6'-0" SPACING AND AS REQUIRED BY TRUSS MANUFACTURER (REFER TO TRUSS NOTES AND TRUSS LAYOUT FOR LOCATION) E DETAIL NTS �• u CML G. FORBO sssLSd role >EA FL DRAWN BY: CARLOS VIIACA 1000 S DIXIE HWY. WEST POMPANO BEACH FLA. 33060 PHONE:561— 445— 9661 EMAIL corloavlloca2®Gmail.com DATE 1+17 SCALE: 3/16' = r-C PROJECT : NOTORiB MPMFS R-20 FOAM R-4.1 WALLS LOW E GLASS U FACTOR 1.02 SHADING COEF .25 FAN SCHEDULE e COMPANY: PANASONIC FAN NO. EF- 1 AREA SERVED TOILETS CFM 50 RPM 1075 WATTS 14 AMPS .11 VOLTAGE 120-1-60 FAN TYPE CEILING CONTROL LT. SWITCH COOLING EQUIPMENT # 8 MAKE LENNOX MODEL XC16SO42 3.5 TON 1400 CFM EFFICIENCY 18 SEER TOTAL BTU 42,000 HEAT PUMP MECHANICAL PLAN HEATING EQUIPMENT # 8 MAKE LENNOX MODEL CBX25UHV-060 EFFICIENCY 100 EFF EFFICIENCY 10.0 KW REF. PIPING 1-1/8 / 7/8 GALVANIZED EXAUST ROOF CAP W/BACKDRAFT DAMPER SLOPED ROOF CAP. WIRE MESH SCREEN INSTALLED ro '� OOF SLOPED 2x4 WOOD BLOCKI G 4' GALV, METAL DUCT 26 GA. BACKDRAFT DAMPER NUTONE EXH. LFFAN CEILING GRILLE SIZE AS PER AIR INLET MFR. SPEC'S EXHAUST N DETAIL N.T.S. v4' = r-T V t SUPPLY AIR LIQUID & SUCTION LINES OVERHEAD RISE IN AHU CLOSET WITH INSULATION AS PER FBCM 2007 EDITION, DROP IN GWB CHASE . FIRE CAULK EXTERIOR WALL OPENINGS. SIZE VARIES, SEE PLAN. 4' CLEAR ON ALL SIDES OF UNIT AIR CLER ADJUSTABLE AIR HANDLER UNIT METAL BASE WITH DISPOSABLE INTERNAL FILTER SD CONDENSATE DRAIN DNE AUX. DRAIN PAN. 1 1�2" DEEP THRU CONDENSATE PUMP X 1" LARGER THAN UNIT IN TO RAC ABOVE CEILINGLENGHT AND WIDTH. LEVEL. SLOPE TO DRAIN FLOAT SWITCH IN PAN THRU EXTERIOR WALL INTO CONDENSATE PIT THUMB SCREWS RETURN AIR RUBBER MOUNTS VERTICAL AIR HANDLER PROVIDE STEEL SLEEVE AT PENETRATION AND SEAL ENDS WATERTIGHT PROTECT REFRIGERANT LINES UP ALONG WALL WITH LINE COVER AND PAINTED TO MA I CH ARCH] I EC I URI= LINE COVER SHALL BE 22 GA. SHEET METAL WEATHERPROOF FASTEN TO WALL WITH 1/S'd CONCRETE NAIL WASHER (2)Ye' PLASTIC COATED STEEL GABLE SECURE TO SLAB W/ S.S. TURNBUCKLES. I CONDENSING UNIT PER FBCM 301. 12 WIND LOAD. FBGB 13fD1 . I, 1620, ASGEi-10 SECURE CONDENSING UNIT TO GONCRIETE PAD WITH V WIDE -_ GALVANIZED SHEETMETAL -_ STRAPS RATED FOR 1i0+ MPH HURRICANE FORCE WINDS (TYPICAL) FIN SLAB ELEV.. 40'-0' ELEV.'1 .60' N.VGD. PROVIDE 3/4' LAG -BOLT TO CONCRETE BLOCK FILL SLEEVE WITH SILIC SEALANT FOAM CTG FIR N B DEEP REFRIGERANT LI 41GH AND TIE TO TRUS 1EMBERS STEEL U BAR IMBEADE THE CONCRETE. TIE DOWN CONDENSING UNIT L NEOPRENE VIBRATION ISOLATORS TO ;SLAB (TYPICAL OF 4) -0 CONCRETE HOUSEKEEPING PAD CONDENSING UNIT MOUNTING DETAIL NTS ELECTRICAL PLAN 1/4A = r_v NEW ELECTRICAL "PAVILION" SUB -PANEL 3 100A M. C. B PANEL 120 / 240v 1N 3W (SURFACE) CKT SERVES CB P KW WW-COND. CET SERVES CB P ET WBRE-COND. 02 FAN/LIGHT 15 1 .8 # 14 01 TP/GFCI RECEPTACLES 20 1 1.5 # 12 04 GENERAL LIGHTS 15 1 .8 # 14 03 TP/GFCI RECEPTACLES 20 1 1.5 # 12 08 RESTROOM LIGHTS 15 1 .8 # 14 05 TP/GFCI RECEPTACLES 20 1 1.5 # 12 08 POOL LTGS 20 1 1.5 # 12 07 RESTROOM GFCI RECEP 20 1 1.5 # 12 10 POOL PUMP 20 1 1.5 1 # 12 09 WATER FALL PUMP 20 1 1 1.5 # 12 12 POOL FILTER 20 1 1.5 # 12 11 REF 20 1 1.5 # 12 14 JACUZZI PUMP 20 1 1.5 # 12 13 AHU #8 60 1 10.0 # 8 16 08 AC COMPRESSOR 8 45 2 # 8 15 18 1 10 (NON-CONCURRENT)77 17 SPARE -- -- 20 1 SPARE 1 19 SPARE -- -- 8.4 ELECTRICAL NOTES: 1. ALL ELECTRICAL WORK SHALL CONFORM TO THE LATEST REVISION OF THE N.E.C. 2011 AND LOCAL GOVERNING CODES 2. ALL WIRING TO BE COPPER UNLESS OTHERWISE NOTED. 3, ALL MATERIALS, WHERE APPLICABLE, SHALL BE U.L. LABELED 4, ALL OPENINGS REQUIRED BY ELECTRICAL CONTRACTOR TO BE CLOSED TO MATCH FINISH AND FIRE RATED BY ELECTRICAL CONTRACTOR. 5. INSTALLATION HEIGHTS ABOVE FINISH FLOOR UNLESS OTHERWISE NOTED: WALL HUNG TELEPHONE 56" A.F.F. TELEPHONE JACKS 12" A.F.F. LIGHT SWITCHES 48" A.F.F. RECEPTACLES 12" A.F.F. TELEVISION JACKS 12" A.F.F. 6. CO-ORDINATE ALL CONDUIT RUNS AND EQUIPMENT INSTALLATION WITH OTHER TRADES TO AVOID CONFLICTS PRIOR TO FABRICATION, INSTALLATION AND ERECTION. 7, ELECTRICAL CONTRACTOR TO VERIFY ALL HVAC UNIT CONNECTIONS WITH HVAC CONTRACTOR PRIOR TO INSTALLATION. 8. ALL METERS, METER CENTERS AND DISCONNECTS TO BE APPROVED BY FLORIDA POWER AND LIGHT. 9. LOCATION OF ELEC. REC. SHALL COMPLY W/ NEC-210-52 AND RECEPTACLE SPACING SHALL COMPLY WITH NEC 210-72. LIGHTING OUTLETS SHALL COMPLY WITH NEC-210-8 10ALL NEW CIRCUITS TO BE ARC FAULT PROTECTED NEC 2008 210.12 11 ALL NEW RECEPTICLES TO BE TAMPER RESISTANT NEC 406.11 19.0 TOTAL 27.4 PLUMBING PLAN 1,C=r-o° NOTE: PLUMBING FIXTURES, FAUCETS AND FIXTURE FITTINGS 2' VTR TO COMPLY WITH REFERENCED STANDARD AS PER FBC SHOWER TABLE P2701.1. TO HOUSE CERAMIC TILE BOND COAT REINFORCED WALL MORTAR BED OUD BACKING O CERAMIC TILE INTEGRATED DRAIN BONDED FLANGE SHOWER PAN LINER CRUSHED TILE SLOPED REINFORCED FLOOR OR STONE AROUND MORTAR BED 1-1 3/4' THICK WEEP HOLES SHOWER DETAIL N.Y.S. SINK PAVILION POOL LAV BATH ISOMETRIC PLAN NU PLUMBING NOTES: 1. THE ENGINEER CERTIFIES TO THE BEST OF HIS KNOWLEDGE, ALL WORK DEPICTED IS IN ACCORDANCE WITH THE FLORIDA BUILDING CODE, INSTALLATION SHALL COMPLY WITH STANDARDS THEREIN. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL EQUIPMENT DESIGN REQUIREMENTS Q MENTS (I.E. VOLTAGE, WATER, DRAINS, GAS CONNECTIONS, ETC.) WHEN REQUIRED FOR THE CORRECT/APPROVED OPERATION, THE EQUIPMENT SHALL BE FURNISHED WITH ALL NECCESSARY ACCESSORIES WETHER CONSIDERED OPTIONAL DR STANDARD BY THE MANUFACTURER EQUIPMENT SHALL NOT BE ORDERED BASED ON MANUFACTURERS' MODEL NUMBERS. 3. ALL MATERIALS AND EQUIPMENT SHALL BE NEW, FREE FROM DEFECTS AND WITH FACTORY WARRANTY, PRODUCTS SHALL BEAR RESPECTIVE A.S.T.M. STANDARD LABELS AND INSTALLED AS PER USTING UNDER SUCH. 4. INSTALL SANITARY LINES AS TO DRAIN WITH SLOPES OF NOT LESS THAN 1/8' PER FOOT FOR 3" SND ABOVE AND 1/4" PER FOOT FOR 2-. 5. INSTALL PIPING AND EQUIPMENT ALLOWING ADECUATE ACCES FOR SERVICE TO VALVES AND EQUIPMENT OF OTHER TRADES, PROVIDE U.L. USTED ACCESS PANELS IN WALLS AND CEILING WHERE ACCESS IS REQUIRED. 6. INSTALL CLEAN -OUTS AS INDICATED ON DRAWINGS AND AT EVERY 75 FEET, BASES OF STACKS AND CHANGE OF DIRECTION. 7. SANITARY, VENT AND RAIN WATER LEADER PIPING SHALL BE SCHEDULE 40 PVC SOIL PIPE WITH DRAINAGE TYPE FITTING, SOLVENT WELDED. PRIME FITTINGS AND PIPE ENDS PRIOR TO WELDING, EXCEPTION: IN AIR CONDITIONING PLENUMS, i.e. MECHANICAL ROOMS, CAST IRON PIPING SHALL BE USED. 8. DOMESTIC WATER PIPE SHALL BE TYPE L ABOVE GROUND AND TYPE K BELOW GROUND. SOLDER FITTINGS USING LEAD-FREE SOLDER, AVOID JOINTS BELOW SLABS OR INSIDE WALLS WHENEVER POSSIBLE. 9. PROVIDE EXPANSION AIR CHAMBERS OF 20 PIPE DIAMETERS BUT NOT LESS THAN 12'. INSTALL AT EACH FIXTURE, GROUP OF FIXTURES, RISERS AND END OF SUPPLY LINES. 10. ISOLATE COPPER PIPING FROM DISSIMILAR METAL, MASONRY OR CONCRETE WITH FOAM PLASTIC, FIRE RETARDANT INSULATION OR SIMILAR METHODS APPROVED BY LOCAL JURISDICTION. 11. PROVIDE PIPE SLEEVES FOR ALL CEILING, FLOORS OR WALL PENETRATIONS PACK WITH FIRE RETARDANT CAULKING IN CONFORMANCE TO U.L SPECIFICATIONS. 12. PLUMBING FlXTURES SHALL BE FIRST GRADE VITROUS CHINA CONFORMING TO ANSI STANDARDS, FURNISH TRAPS, VALVES AND ALL TR COMPLY WITH ALL CODES AND ORDINANCES. A.ERICAN'ISAiIN AR,OB EALMi. a WATER & SANITARY PIPI SANITARY 11 VENT PIPES POLYVINYL CHLORIDE (PVC) PER FBC 2010 TABLE 702.1 TABLE 702.2. TABLE 702.3, TABLE 702.4 A" REVISIONS BY CUDU cgTATQOB CY MF24-17 CARL G. FORBES I z(/u/j sss s xn POMPANO BEACK FL DRAWN BY: CAR70S cRA A 1000 S DIXIE HWY. VEST POMPANO BEACH FLA. 33060 PHONE:561- 445- 9661 EMAIL: carloaviloca2@Gmail.com DATE 1-lo-n SCALE: 3/16' = r-C PROJECT : NXIM CHURCEIRL IF THERE ARE NO MARKUPS ON LAYOUT, THEN TRUSSES WILL BE BUILT AS DESIGNED AND CT WILL NOT BE BACK —CHARGED FOR ANY ITEMS FOUND AFTER THE FACT OF THE RETURNED LAYOUT ALL DIMENSIONS AND CONDITIONS THAT EFFECT WD. TRUSSES MUST BE VERIFIED BY BUILDER AND/OR ARCHITECT BEFORE ANY PRODUCTION OF WD. TRUSSES 10' 5" 9' 8 1 /2" _ 20' 10" 101 511 9' 8 1 /2" EXT. TRUSS 2' 0" 5/8" PLYWOOD CUT END OF TRUSS ABOT 5 1/2" ATTACHED W/5/8" PLYWOOD BOTH SIDES NAIL WIRH 8D's 3" O.C. CONNECT FACE OF G1 GIRDER WITH THD26 HANGERS EXT.TRUSS END DETAIL APPROVED TRUSS ANCHOR BY BUILDER SQUARE CUT OVERHANG HEEL HEIGHT = 8" BOTTOM = 2x4 MIN. TOP = 2x4 MIN. APPROVED TRUSS ANCHOR BY BUILDER SQUARE CUT OVERHANG HEEL HEIGHT = 8" BOTTOM = 2x4 MIN. TOP = 2x4 MIN. ind LOADS -- ROOF FLOOR SCE7 10 MWFRS Design Wind Speed: -- - - 170 mph TCLL 30 40 Type.. _ ''._ _-__ (Building Enclosed TCDL 15 20 - or Category importance Factor -- - II 1.00 BCDL 10 5 Duration on Factor: Roof 1.25 / Floor 1.00 BCLL 0 0 Building Exposure: _ - "C" TOTALI 55 65 Truss bottom chord analyzed with 10psf non -concurrent live load 30 psf concurrent live load on trusses designed with storage space. TRUSS HANGER INFORMATION Check TRUSS ENGINEERING for gravity and uplift values. If the value exceeds the capacity of a hanger shown below, then it is the responsibility of the builder to provide a suitable connection. All 2-ply hanger values are based on a 2-ply supporting girder. HANGER GRAVITY FASTENER CONN. ROOF FLOOR UPLIFT GIRDER TRUSS A THD26 2x6 3060 2645 2265 1846d 12-10d 1 112" B THD28 -2x8 4485 4115 2330 28-16E 16-10d 1 112" C THD26-2 2x6 3355 2770 2340 18-16d 12-10d D THDH26-2 2x6 5245 4375 2340 20.16d 8-16d E THDH26-3 2z6 5245 4375 2340 20-16d 8-16d F THD28-2 2x8 5005 4310 2596 2846E 16-10d G THDH28-2 2x8 8025 7360 3330 36-16E 10-16d H THDH28-3 2x8 1 7835 7595 4370 36-16d 1246d I THD46 - 2x6 3175 I 2540 2285 18-16d 12-10d ---- J HJC26 2X6 U90 2135 16-16d . 5-10d K SKHH46LIR 2x6 2100 i 1680 1345 12-16d ! 6-16d L SKHH26L/R 2x6 1890 1510 2190 18-76d 12lWx112 M SKHH26L-21R-2 2z6 2100 1680 895 11-16tl 4-16dz2 7/2 - - NI I - - 1�i O GTW$2T 2x8 10900 8720 8435 22 - WS3 16 -WS3 S3 P GTWS3T 2x8 - - 12470 11100 12490 28-WS3 1 24-WS3 Q _-.. GTW84T 2x8 12470 11100 12490 i 28 - WS3 24 - WS3 MSTAM241HTWM20 Connection - R OR EQUAL. by bldr. 1545 5 114' Tapcon 9.10d I -. B T RT16A OR EQUAL Connection - - 1380 8-10d 9-10dx1-1IT' by bldr X 2-RT16A OR EQUAL Connection by bldr. 2760 16-10d 18A0dx14/2" _ Y Z (CONNECTOR BY BLDR **IMPORTANT INFORMATION** ALL REACTIONS, UPLIFTS, ETC. ARE THE RESPONSIBLITY OF THE ENGINEER OF RECORD, PER LOCAL CODE. REFER TO THE STRUCTURAL FRAMING FOR INFORMATION. CT IS NOT AND WILL NOT TAKE ANY RESPONSIBILITY FOR ANY TYPE OF THIS INFORMATION. THIS INFORMATION IS THE SOLE RESPONSIBILITY OF THE ENGINEER OF RECORD. BEARING HEIGHT DISCLAIMER: IT IS THE SOLE RESPONSIBILITY OF THE ARCHITECT OR PROJECT ENGINEER REGARDING BEAM ELEVATIONS AND BREAK LOCATIONS FOR CHANGES IN BEAM HEIGHTS. CT BEAM HEIGHT SCHEDULE IS A GUIDELINE ONLY. REFER TO ARCHITECTUAL AND STRUCTURAL DRAWINGS FOR THIS INFORMATION. CT IS NOT AND WILL NOT BE RESPONSIBLE FOR THIS INFORMATION. FIELD BRACING is not the responsibility of the truss fabricator, truss designer, or plate manufacturer. Persons erecting trusses are cautioned to seek professional advice regarding temporary and erection bracing which is always required to prevent toppling and dominoing during erection, and permanem bracing which may be required in specific applications. Trusses shall be erected and fastened in a straight and plumb position. Where no direct top chord sheathing is applied, trusses must be braced at 24" on center maximum. Where no direct bottom chord sheathing is applied, trusses must be braced per local code. Trusses must be handled with extreme care during erection to prevent damage or personal injury. Refer to truss engineering for connection and bracing requirements. These calculations are supplied in order for the ENGINEER OF RECORD to adequately provide for connection and integration of the roof assembly to the supporting structure. Designers of supporting connections are SOLELY responsible for the integrity of their product.Trusses remain our property until paid for in full. Truss layouts and engineering may not be reproduced in part or in full under any circumstances. SHOP DRAWING APPROVAL THIS PLACEMENT PLAN MUST BE APPROVED PRIOR TO COMMENCING OA DA (A A A DA OA OA O OA q A 12 12 TRUSS ENGINEERING OR FABRICAITON. THE BUILDER MUST VERIFY THE 5 COORDINATION OF ALL THE INFORMATION IN THIS PLAN WITH THE ARCHITECTURAL OR STRUCTURAL DRAWINGS. ANY VARIATIONS CD EJ8 0. G1 2 MJk GIRD BOT. 10'-0" / 8'. 8' / BETWEEN THE FINAL PLACEMENT PLAN AND THE ARCHITECTURAL OR \ / STRUCTURAL PLAN IS THE SOLE RESPONIBILITY OF THE CUSTOMER, (h GB7 \ / N CM / AND ANY EXPENSES INVOLVED IN CHANGES AFTER TRUSS FABRICATION �t IS THE RESPONSIBILITY OF THE CUSTOM AND NOT CUSTOM TRUSS LLC. 0 TRUSS END DETAIL VERIFY ALL DIMENSIONS, WALL HGT.s, COL. HGT.s & LOCATION GIRDER LOCATIONS, CLG HGT.s, COFFER CLG. LOCATIONS END DETAILS, PITCH, FASCIA, O.H. & CANT SOME DOWN FRAMING REQ. BY BLDR. DROP CLG., CEILING CHANGE & COFFER CLG. AREAS EXT.TRUSS END DETAIL RECE OCT 3 PEH;Ji St. Lucie Approved By: Date. NOTE: Horizontal and Vertical Truss reactions and uplift calculations are provided by CUSTOM TRUSS LLC., for the JOB ENGINEER OF RECORD to accurately provide support for the ROOF TRUSS SYSTEM and for proper connection of the ROOF TRUSS SYSTEM to the supporting;:: structure. State of Florida Registered Engineer ' CARL G. FORBES, PE FL.Reg.Nos 20699 555 W. POMPANO PKWY. POMPANO BEACH, FL. 33069 (954) 682-6651 Dale: Revisions: CUSTOM TRUSS 1890 W. ATLANTIC AVE. DELRAY BEACH, FL 33444 PH: (954) 786-8800 FAX: (954) 786-8804 SOLTY PLUMBING Job Name: CESPEDES RESIDENCE PAVILLION Job Address: C24 CANAL ROAD Subdivision: Lot: Block: t 4 ST: ZIP: R RICE FL Scale: Date: 1/4"=1' 10/22/2017 #171222 .I � C1013Y