Loading...
HomeMy WebLinkAboutApproved PlansFile BUILDING DEPARTMENT PRODUCT APPROVAL SUBMITTAL AFFIDAVIT OPENING SCHEDULE: SWING DOORS, OVERHEAD DOORS, SLIDINGs DOORS, FIXED GLASS, WINDOWS 4 SKYLIGHTS: PRODUCT MODEL " MANUFACTURER ATTACHMENT METHOD TYPE, SIZE, SPACING 4 EMBEDMENT BUILDING DESIGN PRESSURE EXPIR. DATE APPROVALN EVALUATION AGENCY PRODUCT DESIGN PRESSURE WINDOWS (SINGLE HUNG) 514-100 (IMPACT) PGT 3/16" x 2 3/4" TAPGONS EVERY HOLE. ALL WINDOW SIZES SAME ATTACHMENT, WORST CASE SCENERIO CALCULATED +50,5 / -61,6 +80,0 / -80.0 03/26/2021 16-0114.06 MIAMI / DADE BUILDING DATA 4 DESIGN PRESSURE SCHEDULE PROJECT/NAME GARDNER RESIDENCE ARCHITECT M,A, CORSON 4 ADDRESS: 112460 HARBOUR RIDGE BLVD ASSOCIATES, INC, ALL PRESSURES CALCULATED WITH THE FOLLOWING: I. WIND LOADS BASED ON FLA. BUILDING CODE 2014 8. WALL ZONE (P8F): 4) +50,5 / -54.8 (5TH EDITION) t AECE 1-10, AND 2011 N.E.C. 5)+50.5 / -61,0 2. BUILDING DESIGNED AS: ENCLOSED OPEN 9, GARAGE DOOR (PSF): N/A 3. MEAN BUILDING HEIGHT: N/A FT. ROOF PITCH: N/A /12 10, LOADS: FLOOR 60 PSF INTERNAL PRESSURE COEFlCIENT +/- : 0,18 ROOF/DEAD 15 PSF ROOF LIVE 30 PSF 4, WIDTH OF END ZONE: 4' 11, SHEAR WALLS CONSIDERED FOR STRUCTURE? WIND SPEED: 110 MPH 3 SECOND GUST YES X NO 5. BUILDING CLA68IFICATION TABLE 1-1. A5CE T_ 12. CONTINUOUS LOAD PATH PROVIDED? F,B,C, TABLE 1604.5 II YES X NO 6, EXPOSURE CATEGORY: D ADJUSTMENT FACTOR: 1.61 13. ARE COMPONENT 4 CLADDING DETAILS PROVIDED? 1. COMPONENTS a CLADDING WIND PRESSURE ON: YES X NO ROOF ZONE (PSF): U N/A 14. SOIL BEARING CAPACITY: 2500 PSF 2) N/A 3) N/A PRESUMPTIVE:_BY TEST: X -,ALL ZONES CALCULATED FOR WORST CASE SCENARIO. (10 S.F. EFFECTIVE WIND AREA) F,S.C, 2014 (5TH EDITION) FOR EXISTING BUILDINGS SUMMARY: THE ALTERATION AREA HAS BEEN DESIGNE:Q LEVEL 2 • Chapte 1 the FBC 2014 Existing BUIlding • less tha % of the aggreregate area • The lateral-force-realal system of the existing structure Is adaquate to withstand any new lateral loads of the new addition per Section 903.3 of the 2014 FBC Existing Buildings. • The existing residence has hardwired smoke alarms and the new addition shall be hardwired and Interconnected to the exist, system where accessible Per R314,3 2014 FBC, _ NOTES: a RELOCATE EXIST, ALARM PAD E THERMOSTATE - VERIFY LOCATION W/ OWNER • REMOVE AND REPAIR / REPLACE SHUTTER HARDWARE • REPLACE ALL CAULKING AROUND WINDOWS CLEAN AN0 POLISH FRAMES IN FL. ROOM • NEW PORCELAIN FLOOR TILE (LAID ON 45 DEGR,) THROUGHOUT EXCEPT IN MASTER BEDROOM, M. BATH, M, CLOSETS, • REPLACE ALL SWITCHES AND PLATES + REPLACE 2 EXIST, FL. OUTLETS IN LIVING ROOM a ALL LIGHTS TO BE ON DIMMERS AND TO BE LED a REPLACE EXIST, FLOUR. LTS. IN CLG. COVE W/ LED a CONTRACTOR TO VERIFY ALL R.O. SIZES FOR NEW WINDOWS • WINDOWS TO BE PGT ALUMIN, IMPACT - OR APPROVED EQUAL - MATCH EXIST, SIZE 4 SHAPE Q-Z� e e da � avD ° EXIST, CLG. 4 CONC, FL. 0 4 1 OF UNIT ABV, TO REMAIN I II I r D�R 1/2"DRYWALLON 3/4" P.T. EXIST. PORCH BM,—/ TO REMAIN I FURRING o 16 O.C. W/ AL -FOIL I R 2 EXIST, SL. GL, DR. 'i'O REMAIN, REMOVE EXIST, SL. GL DR, - SEE PLAN EXIST, SL. GL, DR, CONC, OVER -POUR LEVEL W/ EXIST. SLAB O " FIN. FL. I-V4 a O44. a a 4 a a^ a a 'l a A .4 R EXIST, PORCH SLAB POUR SLAB UP TO EXIST, CURB/TRACK, USE FORMA P WINDOWS, VERIFY RECESS ON THE JOB. EXIST, COFF, CLG, W/ COVE LIGHTING 4 CROWN MOLDING EXIST, HOUSE SLAB GENERAL ,ADDITION NOTES: -THE DETAILS CONTAINED PER THESE PLANS MAY NOT BE EXACT AND SHALL BE VERIFIED PRIOR TO ANY CONSTRUCTION BY OWNER AND/OR CONTRACTOR (SUB -CONTRACTOR), OWNER AND/OR CONTRACTOR (SUB -CONTRACTOR) SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO STARTING CONSTRUCTION, "EXISTING CONDITIONS ON ADDITIONS/RENOVATIONS ARE TO BE VERIFIED BY OWNER AND/OR CONTRACTOR (SUB -CONTRACTOR) EXAMPLE: EXISTING EXTERIOR FINISHES, TRIM MATERIALS, ETC, *OWNER AND/OR CONTRACTOR (SUB -CONTRACTOR) IS RESPONSIBLE FOR PROVIDING AND VERIFYING DESIGN GUIDELINES AND RESTRICTIONS PER SUBDIVISION'S ARCHITECTURAL REVIEW BOARD. aM,A, CORSON 4 ASSOC. INC, SHALL NOT BE LIABLE FOR ANY LOSS, DAMAGE OR INCONVENIENCE ARISING FROM INACCURACIES. AREA CALCULATIONS Exist. AC 2364 S,F, Exist. Porch converted to AC 695 S.F, Total A/C 3059 S,F, Total Under Roof 3059 S,F. • Contractors to verify all footages ° All areas are calculated to outside dimensions, WALL LEGEND ------------- HATCHED AND HOLLOW= EXISTING. WALL TO REMAIN SOLID = NEW WALLS DASHED = EXISTING WALL TO BE REMOVED II�®ltJ�. H ®P1GAVILL���.17 e1��l.11�PWI�lSJJ1d1G SLIDING GLASS DOOR: ADD I/2" ONTO 6,6,0, MANVF. (UI07PI ! 114" TO HL WINDOWS: FOR 5/B"WINDOW FIN, 6UBTR4C7' P FROM T/P TO TlP FIN WUIDTH ! Al (VERIFY W/ MANJF.J EXAMPLE: 3'I" x 5'3" WINDOW 81ZE - R.O. SIZE 3'O" x 512" NOTE: CONTRACTOR AND FRAMER TO VERIFY WINDOW MANUF, SPECS (FIN SIZE, WINDOW DIMENSIONS, ETC,) TO VERIFY R.O. DIMENSIONS. -31" x 53" TV - RECESS WALL AS REO'D. _ WD. MANTLE - FIRE- PLACE BELOW W/ TILE SURROUND BASE CAB, W/ ADJUST, GL, SH. ABV. - VERIFY DESIGN W/ OWNER FIREPLACE ELEVATION 4' Ellx 61 411 SH 36 (VERIFY - MATCH EXIST.) EXIST. WINDOW TO BE REMOVED t WALL IN -FILLED (SEE DETAIL) - 5/8" STUCCO ON P.B. MTL, LATH ON TYVEK ON 1/2" CDX PLYWD. SHEATHING ON 2X8 WD, STUDS ATR IllO,C, U z ' EXIST. S.G.D. EXIST. S.G.D. EXIST. S,G.D, r d N -------�-�------------ ---- ----------------------------- 0•�a a 0 ry n n I, II (3) SH i 26 II II II II TILE FL. ON I p 4 9' x 6 4" r OVER -POURED CONC. LEVEL W/ EXIST. I `n (VERIFY - MATCH EXIST.) I NXX NEW DECOR. —SMS. ABOVE I BEDROOM 03 - - - - - - - ------------------ -------------' - - - - - - - - - - - REMOVEEXIST.S.G.D. R OVE EX 1-6T. S.G.D.---------------------------- a I I I -------------------------------------------------------- 13' O" ^;3' O" all 10' 8" NEWI I RERMr�VE NOTE: ;i FLORIDA EXISL, REMOVE EXIST, I DBL. bR. LIVING ROOM - FIREPLACE - VERIFY;; ' REMOVE EXIST. NEW FIREBOX INSERT; ROOM I p WETBAR t SHELVES B SIZE W/ OWNER - EXIST. lOFF CLG. " �7 TILE FL. REMOVE STONE FACd t I/2" DRYWALL WALLS ON Ix I N RAISED HEARTH - " P.T. FURRING a 16" O.C, I N 'i „ a DRYWALL FINISH - TV" x ABV, - TILE SURROUND'_- T4G CYPRESS CLG. ' W REPLACE EXIST, WE). MANTLE DRs. %u/ NEW I REMOVE EXIST. WIN. - NEW BASE CAB. (W/ DRAWER) ` ----------------- ---------- --- < SH BELOW t ADJUST. GL. f� ' I - I SHELVES ABV. (2 PLACES) I BATH REMOVE \ RE -SHAPE COFFER a EXIST, DR. I ,'-\ \ \ AS NEEDED7NEW _-_--- \ g, KITCHEN ---------- I I FOYER\ \ KITCHEN 1 REMOVjE EXIST. I COFF CLG. - MATCH EXIST. I I OPN -ENLARGE DINING I di' TILE FL, I I I r I TILE FL, ON r l 6l, 1� O„ 3, 61, A 7x( I I �OVER -POURED J ' W CONC, LEVEL W/ EXIST. , EXIST, DOOR TO 1 REPLACE EXIST. : BE REMOVED SCREEN DR, W/ WiN9: ' ; I 1 4 WALL IN -FILLED NEW SCREEN DR. (SEE DETAIL)-' -- V£G. SINK; � - - - - - - - - - - - ------------ - � ENTRY ' i - ------ : -- ?---- r Ur - I O r °p � � I, I cQ (y EXIST 8 G D '6 LAUNDRY REMOVE EXIST. - ISP. Dw WINDOW - NEW +/-351' I REMOVE 11 (2TRA H _ _ _ _ _ � 'r _,, ; _ _ j HIGH 1/2 WALL - EXIST. DR, I I " ', VERIFY W/ OWNER 2 O `-----•f 8, 2„ TILE FL. ON OVER -POURED CONIC, LEVEL 20' 10" DESK I W/ EXIST. I O oven/micro ----- 30"COtKTOP tower w/ tv 6"ABV. In cab. abv. ''0__Pantry Pant - cab, cab. 6ro REPLACE DOOR �r 20 WEATHER- STRIPPING , I REMOVE EXIST. TUB t INSTALL NEW SHWR. W/ TEMP. / FRAMELESS GL. ENCLOS, - VERIFY W/ OWNER BEDROOM 02 BA46 9'3"x6'4" 3'1"x4'2" (3) SH 26 SH 24 (VERIFY - MATCH (VERIFY - MATCH EXIST,) EXIST.) W, I,C. NEW WALL FULL HT. FIN, W/ DRYWALL IONCEALED FASTENERS REPLACE EXIST, OR ATTACHMENTS DOOR - NEWINT,WD. FR. z N ARETHEPUPONSIBILITYOFTHE CONTRACTOR OF won ADD BLOWN -IN INSULATION x w U IF NO INSULATION 15 EXISTING - "' = 4 "' VERIFY ON THE JOB N ALL MANUFACTURES CABLES SHOWING U FACTORS AND SHGC COMPLIANCE WITH FBC ENERGY CODE MUST MASTER SUITE REMAIN ON ALL DOORS AND WINDOWS UNTIL INSPECTIONS ARE APPROVED &ESE PLANS AND ALL PROPOSED WORK a :ARE SUBJECT TO ANY CORRECTIONS -N '' tREQUIRED BY FIELD INSPECTORS THAT [MY BE NECESSARY IN ORDER TO C010PLY ITH ALL hPPLIC'A6'o CODESr': 2 2 x 6 Blip[ (MATCH EXIT.) I I i i s,itic�`r"nok x LET n" ; I!IVISYON a N I t?F,t✓IFR 11J i t)6' „®i JtiCE ikjEvIEW BY ? sc=�i I DATE y MASTER BATH I I PLANS AND PERIIIIT MUST BE KEPT ON JOr _ _ I OI: NO INSPECTION WILL BE MADE. 7777 I 1 1 I I ----� MY we 10 a c m s ti u ?� w m Z Ndo Qm�gQ9 Q) o moo you u��omom�`a �m�mm33i^ DATE 05/15/1-7 DRAWN BY pa me CHECKED : Mc REVISIONS : Pressure treated full length Stud against 8" x 16" column block, with precut Stud adjacent. Attach both Studs to poured column block with 1/2" x 7" Redheads, or equal, at 24" o,c„ Use Palm beach Gouril 3" x 3" x 1/4" steel washers at each bolt. Hold frame wall 1/2" inside column blocks so that 1/2" cdx sheathing butte to block, SECTION vIEW Provide 2 "5 bare hooked from footer to tie beam, If "U" block type beam is used hook one 05 Into each course, outer bar to top course, Tnner bar to bottom course. I" \III. * I:', IL'YMAK1 NAILING SG-I;�DULE EDGE FIELD ITEM NAIL SIZE SPACINQ ISPACING NOTES ZONE 1 4 2 - All Joinf In roof decking shall be (ed round head 4" o,c. 6" O.C. covered w/ min. OF 4" wide selF- 19/32" CDX ring shank) adhering polymer modified bitumen ZONE 3 Roof sheathing tape applied drectly (ed round head 4" o.c, 4" o.c, to the aheathing (secondary water banger) ring shank) Roof sheathing so round head a" o.c. N/4 Nail 2. fascia to trues ends w/ (2) tc top of fascia rind shark l6d roils (min.) i5/32" CDX ed 4" o.c, 6" o,c, Wall sheathing 23/32" T4G IOd 4' o,c. 6" o.c. Glue &Il plywood Floor sheathinglPL400 ore uaU Stud to 16d 3 per header ply 2 x 12 header Top plate splice 16d 8 per splice Plate overlap minimum 24", over I stud 14 ga., IN' leg. 3/4" Install lath per ASTM C-I063-99, self- Wall metal lath &" a F. along furring diamond lath, Overlap paper crown staples framlh8 member I IR", overlap lath 1" min, at edges Calling 4 soffit 6d x 1/4" head 6" d.r, along Install lath per ASTM C-I063-99, metal lath roofing palls, (1 3/4" framIrg member High ribbed lath min, embed, I" min. Overlap at edges y_S, 1 EDGE ' T vl O O L O O O O 8 O O RIDGE O O `r O O 1 w 4 O 0 2 _0 m O (D ROOF SHEATHING NAILING ZONES 501`, OF BM. VERIFY FIT.- - — EXIST. PORCH COL. jj)0'O" FIN, FL. I 2"x&" P T. TOP PLATE W/ SII'IPSON H4 CLIPS AT EA. STUD P.T. 2"x8" - 10 SEE FRAME v TO BLK. 0 In DETAIL F - STUDS X a 16" O.C. 2"x8'I P.T. SILL PLATE v -W/ SIMPSON 44 CLIPS EXIST, PORCH SLAB POUR SLAB UP TO EXIST, COL. VERIFY IN FIELD a^ 1/2" )INS a J/4"x3 1/2" TAPCONS • S" O.c. P,T. 211x8" - SEE FRAME TO BLK, DETAIL EXIST, CONIC. WALL / COL. EXIST, HOUSE SLAB ELECTRICAL LEGEND ELECTRICAL SYMBOL 2' Under Cabinet Lights I—.r-. —{ Can LightF } Garbage Disposal 0 cable tv outlet Q outlet 0 outlet 220v VW outlet gfl, switch $ switch 3 way $ 3 2011 NEC 210,12 (A) Arc -Fault Clrcult-Interrupter Protection, Dwelling Units. All 120-volt, single phase, 15- and 20-ampere branch circuits supplying outlets Installed or devices In dwelling unit kitchens, fail rooms, dining rooms, living rooms, parlors, libraries, dens, sun rooms, recreation rooms, closets, hallways, iaundy areas or similar rooms or areas shall be protected by any of the means described In the NEC 2011 210.12 (AXI) through (W 2011 NEC 406,12 Tamper -resistant receptacles In are required In dwelling unite In all areas as specified In 2011 NEC 406.12(A) through (C). All 125-volt, IS- and 20-ampere receptacles. Florida Building Code 5th Edition (2014) Energy Conservation C402.4.8 Recessed lighting. Recessed luminaires Installed In the building thermal envelope shall be sealed to limit air leakage between conditloned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate of not more than 2.0 cfm (0,944 L/s) when tested in acicordance with ASTM E 283 at a 1,51 psf (15 Pa) pressure difFergntial, All recessed luminaires shall be sealed with a gasket or baulk between the housing and Interior wall or telling covering, LOAD CALCULATIONS s ------------------- �� II II II II II II II II II Vol - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - I I i i i I J LL - - - - - - - { - - - - - - - - - - ---- i 'll I I 1 �r -------------- I --------------------------------- — -----------------' / I � I \ _ CC ♦ S - - - - ------------------- vill r , i r i r , � r II ree10 III• d W ff a J um u _ w u z 0 67E Old m 4."cQ'6v0Q9 Wmv x m `z o �a 63,. ✓ s4' a U 0 m m V U d��Q�w"ate • �z W � a 4a U N� or�el b VJ �M...III PC � oo� EM4 vW; a a UN ° o � .V DATE 05/15/17 DRAWN BY pe me CEECIEW : Mc REVISIONS A/C NOTES It shall be the responsibility of the A/C contractor to produce an operational system In accordance with these drawings, The A/C contractor shall furnish installation details and schematics Of all equipment to others who connect to the A/C equipment, i.e. Electrical and Plumbing contractor. Ductwork shall be 1" thick fiberglass w/ taped joints unless noted otherwise, Provide condensate overflow pane under all units Installed above ceiling. Provide adjustable, opposed blade dampers at all diffusers. Provide adjustable extractors or splittere at tape into ducts or where ducts change directions. Alrconditloning supplier shall guarantee the complete system, parts and labor, For one year after first operation. The compressor shall be guaranteed for an additional 4 years, parts only after first operation. Install filters at RAG's. Provide easy access to filters. Rater to energy calculations for A/C unit SEER requirements, GENERAL NOTES: Contractor, subcontractors, material suppliers, etc. Shall make themselves familiar with the contract documents and shall verify all dimensions, conditions at jobSite, plane, Specifications, etc. ae applicable and report any discrepancies, errors or omissions to the architect prior to any work being performed, otherwise we assume no responsibility for any errors and the contractor, subcontractor, material supplier, etc. Shall assume full responsibility for error$ and/or delays and correct them at their own expence Changes, revisions, or alterations not made by this office In writing only, will fully, unconditionally and totally release the architect, its employee$, consultant$ and design professions, from any and all responsibility, The architect has not been retained for the supervision or the administration of the execution of the work of this project, Each contractor shall be responsible for construction means, methods, techniques, sequences, and procedures for safety precautions and Shall comply with the requirements of O,S.H,A, all applicable building codes and all governmental agancieshaving jurisdiction. Each contractor shall make all arrangements for, obtain and pay for all permits, tests, inspections, and approvals required for his portion of the work, All work shall be guaranteed for a period of at least one year From the date of acceptance. Stucco shall be two coats approximataly 5/8" thick applied to masonry, 3/4" thick applied to metal lath. Lath shall be flat expanded diamond mesh galvanized, paper backed, weighing not lees than 3.4 pounds per sq. yard. Glass Shall be float, tinted with shading coefficient of ,11 cat.[[, 3/16" tempered for operable glass doors. Tempered glass shall comply with ANSI-Z 91.1 (all glass at ehowere/tube to be tempered). Caulking using Tremco or so, eilTcon-type products shall be applied at all Junctions of wall and window and door frames with abutting wall surfaces to provide a weathertight water-resistant Installation. ELECTRICAL NOTES Electrical contractor Shall comply with the N.E.C. and all applicable codes or authorities having jurisdiction. Electrical contractor to coordinate exact locations of all hvac equip. 6 it's loads w/ mach, contractor before roughing -In for proper power and wiring control layout and installation. All outlets, switches and light fixture locations to be verified by owner on walk-thru with electrical contractor. All 110 V, 10, 15 and 20A, receptacles installed outdoors and In bathrooms shall have ground fault circuit Interrupter. Unless otherwise noted, minimum size wire Shall be 012 "AWG", excluding control wiring. Smoke detectors to be powered by house electric service w/ battery back-up, Visible "Power on" Indicator and a test button. Verify all conductors and breakers w/ egiup. manuf, apace. All elect, switches shall be 48" a,f.f, unless otherwise noted, All receptacles shall be 12" a.f.f, unless otherwise noted. Closet lighting Shall be min. 18" clear from edge of shelves. PLUMBIN.� NOTES It shall be the rponsibility of the plumbing contractor to produce an opetional system in accordance with these drawings. The plumbing coractor shall guarantee the complete System, Parts and labor, it one year after first operation. Installation and merials shall be In accordance with the Standard Plumbing Code td all local codes. Plumbing contr4C$r shall verify location, elevation, and size of existing mains befre fnStallatlOn TO started. Provide vacuum lteakers on all hose bibbs and faucets with hose end connecbne, Fixtures shall be potacted against water hammer with air chambers as required by cde, Provide shutofr valves In the potable water Supply and each place of equipmat, Insulate condeneate lines. All hot and cold eater Knee Shall be copper type "L" for under- ground and type "I" for above ground tnetallatton w/ silver Soldered joint$. NOTES: • CONTRACTORS TO VERIFY ALL SQUARE FOOTAGES • CONTRACTORS TO VERIFY ALL INTERIOR BEARING WALL FTG. W/ TRUSS MANUF. • CONTRACTOR TO VERIFY LOCATION OF ALL UTILITIES AVAILABLE AT SITE BEFORE PROCEEDING W/ CONSTRUCTION REPORT ANY DISCREPANCIES TO ARCHITECT BEFORE PROCEEDING W/ WORK DUROGK SHALL BE USED IN ALL DAMP LOCATIONS i IN ALL SECOND FLOOR WALL AND FLOOR TILE AREAS PROVIDE PLUMBING ACCESS PANELS TO ALL SLiP JOINT CONNECTIONS • TEMPERED GLASS TO BE USED AT ALL HAZARDOUS AREAS ALL BATH ROOM WALLS SHALL BE INSULATED ALL LUMBER IN CONTACT W/CONCRETE OR MASONRY SHALL BE PRESSURE TREATED ALL FRAMING (WALLS 4 ROOF) LUMBER TO HEMFIR Fb 1000 MIN, STUCCO SEALANT ALUM. WIP SEALAN' HEAD CONCRETE TIE BEAM OR JOMPOSITE BM. - SEE ;ZOOF PLAN P.T. I'k4" P.T. WD. BUCK ANCHOR TO TO CONIC. / CONIC. BLOCK W/ CONT. VIILCOM CAULK AND CASE HARDENED NAILS AT 4" O.G. ATTACH WINDOW THRU BUCK W/ 1/4" TAPSONS AT EVERY HOLE OR PER MANUF. W/ 1 1/4" MIN. EMBED. SILL PER PLANS AND OWNER 'CURED CONC. SILL V' HT. MIND ILL 1 1/2" = 1'-0" 18" LONG 03 DOWELS w 24" O.C. on ea. SIDE STAGGERED x TRENCH WIDTH. DRILL < EPDXY ro" INTO EDGE OF EXIST, SLAB .....rfttt...... ..................................:.::::....rm$>... ...............:::::........................ ........... :...................................... , "3 BAR CONT. 6 MIL. VAPOR BARRIER ON COMPACTED 4 TREATED FILL. SLAB ON GRADE PATCH 3/4 99=1 '(D" NOTE: SLAB PATCH FOR MECHANICAL TRENCHES - MATCH EXISTING THICKNESS BUT NOT LESS THAN 4" W • 4Z I� EM4 A � E PC ;0. •• E • O � � �aa aUN ° N O ~ � U am r r DATE ; 04/21/11 DRAWN BY p. me CHECKED MG REVISIONS H, 1 9 ou 114 C==== 3