Loading...
HomeMy WebLinkAboutProduct Approval BOS Home I Log In User Registration n H6E Tapirs Submit Surcharge ', Stats&Facts I Publications FBC Staff (.' BOS Site Map {! links j db r3 Product Approval , 09 —OZO �~ USER;Public User ST.LUCIE C� -*-TV— EL'II..3' P?G TJIS'I�SIO`1 BFVIEWED FOR CON NCE ProduaAooroval Menu>Pro ductor.AooIlcatlon Search>Aoolication Liist.>-Appl I �Ica D ` �IvL'�WED B FL# FL9777-R9 DA TE +21 PLANS AND PER MUST BE KEPT ON J03 Application Type Revision OR NO INSPECTION WILL BE MADE. Code Version 2014 Application Status Approved i Comments Archived Product M.anufadurer Owens:Corning Address/Phone/Email One Owens Corning Parkway Toledo,OH 43653 (740)404=7829 g reg.keeler@ owe,n sco m i ng:co m Authorized Signature. Greg keeler THESE PLANS AND ALL PROPOSED WORK greg.keeler@owenscff"rt�} CT TO ANY CORRECTIONS REG IU RED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO Technical Representative COMPLY WITH ALL APPLICABLE CODES. ,Add ress/P.hone/Email Quality Assurance Representative Address/Phone/Email a Category Roofing COMe @?Aio s OR AP m Subcategory Underlayments ARE Nq Rnponeoly of 4% ' p ��'hC YOR I a��i��h Compliance_Method Evaluation Report a Florida Regis ered A hector a,Licensed F Professional Engineer Evaluation Report-HardcoPy,Received Florida Engineer or Architect Name who developed the Zachary R.'Priest Evaluation Report Florida,License PE-74.021. Quality,Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/,31/20`L0 Validated;By Locke Bowden e. Validation,Checklist-=Ha.rdcopy Received Certificate of Independence FL9777 R9 COI 0CR14002 6a FBC 2014 Evaluation Report Weathei Non-HVHZ'FINAL,odf I Referenced,5tand6rd and Year(of-Standard) Standard - Year ASTM'D 197.0 2009 ASTM D 226 20.06 ASTM G155 2005 TAS 103 1995 UL'1897 File C® 2004 Equivalence of Product Standards i f f E Certified By Sections from the Code j Product'Approval Method Method 1 Option Date Submitted b4/.12/20i7 Date Validated 04/12/2017 Date Pending;FBC Approval 04/13/2017 Date Approved 66/,13/2617 Summary-of.Products 'FL# i;Model,Number:or Name Description 9777.1 Weatherlock G Weatherproofing Underlayment i Limits of Use ,. _. .. _. Installation Instructions Approved:for use in HVHZ: No: Fk9777 R9 II OCR14002.6a FBC 2014 Evaluation Reoor Approved for use"outside HVHZ:Yes Bath rial Non-HVNZ FINAL odf i Impact Resistant:N/A_ Verified By:Zachary R.Priest 74021 Design,Pressure.N/A Created by Independent Third Party:Yes Other:see evaluation report for limits ofuse. Evaluation Reports FL9777 R9 AF OCR1400 6a PBC 2014'Evalua Lon Reoo 1 WeatherloCk Non-HVHZ FINAL,12 1 Created by Independent Third Party:.Yes 9777.2 'Weather'Lock G(High:Tear) Weatherproofing:Underlayment Limits of Use, 'Installation Instructions: Approved for use m NVHZ.:No FL9777 R9 I1 OCR140Q2 6a FBKI2014 Evaluation RPDor Approved for use outside HVHZ;.Yes Weathe"dock Non-HVHZ FINAL Ddf Impact Resistants N/A Verified By::Zachary it.Priest PE-74021 Design Pressure: N%A Created by Independent Third Party: Yes Other:See,evaluation.report for limits of use, Evaluatiod Reports FL9777 R9 eE OCR14002. FBC 2014 valuaiion Raoc Weathercock Non-HVHZ FINAL Ddf Created by Independent Third Party: Yes #�9777.3 Weathercock M �AT Waterproofing Underlayment F Limits of.Use Installation Instructions Approved for use in HVHZ:Yes FL9777 R9 TI OCR14002'6b FB"C'2014 Evaluation Repor Approved for use outside.HVHZ: No. Weatheriock'HVHZodf :Impact Resistant: N/A verified By:.Zachary R:_Priest 14021 I Design Pressure: N/A :Created by Independent Third Party:Yes it Other:See evaluation report for limits of use. Evaluation Reports FL97-77 'R9 AE OCRia002 bb FBC 201°4 Evalua_tlOn�Renr; t Weatherlock HVHZ,Ddf ( Created by Independent Third Party: Yes 9777.4 Weatherlock MAT;, waterproofing Underiayment Limits of Use Installation.Instructions Approved,for use in HVHZ No FL9777 R9 IF QCR14002 6a FBC 014 Evaluati+2n Reoor Approved#or use,outside HVHZ:Yes Weatheriock Non HVHZ FINAL n4f Impact.Resistant: N/A Verified By: Zachary R Priest A021 Design Pressure:N/A, 1Created by Independent Third Party:Yes Other:See evaluation report:for-limits:of use., Evaluation Reports' FL9777"R9-& OCR24002 6a FBC 2014 Evalua can Repo- Weatherlock Non-HVHZ FINAL odf - Created by Independent Third"Party:Yes ; 9777 5 WeatherCeck Metal Weatherproofing Underlaymen_t Limns of Use; Installation,Instructions Approved for use in HVHZ:No• FL9777 R9 II OCRIA007.6 FBC 2014 Evaluation Reoor a Approved for use outside,HVHZ:Yes )lleakheHack Non-HVHZ FINAL pair Impact Resistant: N/A Verified By.-Zachary R. PriestPE-74021 Design Pressure. N/A Created by Independent Third Party:-Yes I Other:See evaluation report for limits of use. Evaluation Reports {k FL9777 R9 AE OCRI4002 6a FBC=2014 Eyai'ia fon Reoo i Weatherlock Non- HVHZ FINAL.pdf Created by Independent Third Party:Yes 77.7. of Use WeatherLock Metal Weatherproofing Underlayment Limits .I.nstallation Instructions Approved for use in HVHZ:Yes FL9777 R9 H OCR14002.6b.FSC 2014 Evaluation Repor Approved for use outside HVHZ:"No ;Weatherlock HVHZ'.Pdf Impact Resistant: N/A Verified.By Zachary'R: Priest.PE-74021, Design.Pressure: N/A Created by Independent Third.Party: Yes Other:See evaluation report for limits of use. Evaluation Reports ( FL9777' R9 AE OCR14002.6b FBC 2014 Evaluation Ren Weatherlock HVHZ.pdf: created by Independent Third•Party:Yes; 9777.7 WeatherLock Specialty Tile&Metal Weatherproofing Underlayment j.Limits of.Use . Installation Instructions I Approved for use in HVHZ:No FL9777 A9 I1 OCR14002 6a FBC 20i4 Evaluation Repor I Approved for use outside HVHZ;'Yes Weatherlock-Non-HVHZ FINAL.odf j Impact Resistant:N/A Verified By,:Zachary R: Priest 74021 Design'Pressure: +0/-105 Created by jndependent Third.Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL9777 R9 AE 0CR14002 6a FBC 2014 Evaluation Repo Weatherlock Non-HVHZ FINAL.bdf Created by IndependentThird Party:Yes: 3acY.. t+e!st Contact Us,::Zrao1 Blair Stone Road Tallahassee FL 32399 Phone:'850-4874824 The State of Flarida Is an AA/ItEO employer.Copyright 2007-2013-State of"Florida.:'Privaot Statement::Accessibility Statement Refund Statement Under Florida;law;emall,addresses are.public records::If you:do not want your e-mail address released:in response to a public-records request,do.notsend ele mail to,thisentity.Instead,contact the office by phone or by traditional map:If you have"anyquestrons,-please contactB50.467.1395.*Pursuant to Sec[i 955.275(1),,Fior!da Statutes,effectiVe,October 1,.2012;licensees licensed underChapterASS,F.S.must provide the Department with an email address if the-: one..The emalls provided may be used for official communication With'th'e licensee.However addresses-.are public record.If you do not wish to.supply p address,please provide the Department.yiikh an emaif address which_can be made'availahie to tlie'public.To determine if.you are a`licensee.under Chapter4.5; Please clicKfiere Product Approval Accepts:: IMM M Na"— M Credit Card Safe ' I i I 1 , Certificate of Authorization No.29824 17520 Edinburgh Drive CREEK Tampa,FL,:33647 � TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT 'FLORIDA BUILDING CODE 5"EDITION(2014) Manufacturer: OWENS CORNING.ROOFING AND ASPHALT LLC Issued April 12, 2617 1 Owens Corning:Parkway Toledo,OH 43657 (800)438-7465 www.owenscorning.com Manufacturing Location: Brentwood',NH' Houston,TX Quality Assurance- UL LLC(Q.VA9625). SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1504.3.1,1.507.2.4, 1507,2.8, 1507.2:9.2;1507.3.3, 1507.4.5, 1507.4.5:2; 1507.5.3., 1507.5.3.2, 1567.1.3,1507.7:3;2 Properties: Physical properties REFERENCES `Entity Report No. Standard' Year PRI.Construction Materials Technologies(178T6049) NEI-039-02-01 ASTM D1970 2009 PRI Construction Materials Technologies(TST6.04% NEf-042-02-01REV2 ASTM D"1970 2009 PRI Construction Materials Technologies(TST6049) NEI-045-02-01 TAS 103 1995 PRI Construction Materials Technologies(TST6049) NEI-045-02-01 ASTM G 155 2005a PRI Construction Materials Technologies(TST6049) NEP05.3-02-01 TAS 103. 1995 PRI Construction Materials Technologies(TST6049) NEI-053-02-01 ASTM G155 2005a PRI Construction Materials Technologies(TST6049), , NEI-093-02-02 ASTM 6100, 2664 PRI Construction Materials Technologies,(TST6049) " OCF=213 02=01 ASTM D 1623 2009 PRI Construction Materials Technologies'(fST6049) 0CF=237-02=01 UL 1897 2004 PRI Construction Materials Technologies(TST5878) OCF-252-02-01 ASTM D 47.98 2001; PRI-Construction Matenals`Technologies(TST6049)1 OCF=252-02=01 ASTM D 1970 2009 PRI Construction Materials Technologies(TST5878) OCF=253-02-02 ASTM D'1970 2009 PRI Construction.Materials Technologies(TST6049) OCF;272702-0.1 TAS 103 1996 PRI Construction Materials Technologies(TST6049) 0CF-296=02=02 [CC-ES-AC,188' 2012 [CC-ES AC,48 2012 PRI Construction Materials Technologies(TST6049) 0CF-297=02-011 ASTM D 1970 2009 'Determined to be equivalent to ASTM D.226=06;Type Land 11. I OCR14002.6a 171,9777-R9 Page 1 of 4 Technical Seances,LLC of any product changes or quality assurance changes throughout the 1. ...durationmanufacturer . I.. notify CREEF< This evaluation report is provided for State of.Florida product approval under Rule 61 G20-3..The m for which this report is valid.- This:evaluation report does!not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically.addressed herein. i I , r CREEK OWENS CORNING'ROOFING AND ASPHALT LLC I-i K WeatherLock®Self-Sealing Ice&Water.Barriers 'TECHNICAL SERVICES,LLC PRODUCT DESCRIPTION AND LIMITS OF USE WeatherLock@-G WeatherLock@.G is-an ASTM.D 1970 self-adhesive underlayment constructed:from SBS (Brentwood;.NH) modified asphalt, a 'fiberglass mat reinforcement and surface..d with granules. The product is supplied in 2-sq.rolls With nominal dimensions of 3.-ft x 66;74. VeatherLock@ G is permitted to be used with:mechanically fastened asphalt shingles, wood shakes.or shingles,and slate roofing as prescribed in the'FBC. Exposure on the roofdeck shall be limited to a maximum 30 days. WeatherLock®Mat WeatherLock( Mat is an-ASTM D 1970 self-adhesive.underlayment constructed from (Brentwood,NH.or SBS modified asphalt-with a fiberglass mat reinforcement. The product is supplied in 1 Houston, 7X) sq.rolls.with nominal dimensions of 3-ft x 33:3=ft:and 2 sq. rolls With nominal dimensions of•3-ft.x 66.7-ft. WeatherLock®Mat is permitted to be used with mechanically fastened asphalt shingles, wood shakes or shingles,,and slate,roofing as prescribed in,the FBC. :Exposure on the roof deck shall be limited to_a maximum 3-0 days.. WeatherLock®Metal WeatherLock®Metal is an ASTM D 1,970 self-adhesive underlayment constructed.from (Brentwood, NH) SBS.modified asphalt with a fiberglass mat reinforcement.and plastic film surface. The product is supplied in 2.0 sq,rolls with nominal.dimensions of3=ft x 66.7=ft. WeatherLock@ Metal is permitted to be..used With'-mechanically "fastened asphalt shingles, metal roof panels or-shingles,.wood shakes or shingles, and slate roofing as prescribed'in the FBC. Exposure on the roof deck shall be limited to a maximum 90 days. WeatherLock@ WeatherLock® Specialty Tile& Metal is an.ASTM D 1970 self-adhesive undedayment Specialty Tile 8.Metaal constructed from SBS,modified asphalt and surfaced.with a:non-woven,polyesterfabric. (Brentwood,NH) The product is supplied in 2.14 sq.;rolls;with nominal dimensions of 3-ftx 71.3-ft: WeatherLock@ Specialty Tile&Metal is permitted to,be used-with mechanically fastened asphalt shingles, clay_or,concrete tile, metal,roof panels-or shingles, wood shakes or shingles, and,slate roofing as prescribed in;the FBC:- WeatherLock@ Specialty Tile. Metal is permitted to be used with adhered clay,-or concrete:the roofing using either 3MTM 2-Component Foam Roof Tile::Adhesive-AH=160 (3M.Company) or TILE BONDTM Roof Tile Adhesive;(The Dow Chemical Company), Exposure:on the roof deck shall be limited to a.maximum 90 days. i The maximum roof slope shall be-6:12 when.used with clay or concrete tole installations without flattens. Tile shall be stored on battens'46r.roof slopes greater than 6:12. Tiles shall not be stacked greater 10 tiles per.,stack, WeatherLock@•G(High WgatherLock®'G(High Tear)is a.self-adhered underlayment used as an alternative to Tear). ASTM D 226,Type I or Type II roofing felt and ASTM D 1970.self-adhering polymer (Houston, TXJ. modified bitumen underlayment. The underlayment'is composed ofSBS modified, asphalt with;a fiberglass mat interpal reinforcement.and is surfaced with,granules..The. product is supplied with a nominal thickness.of o mils.in 1:95-sq rolls>with nominal dimensions of3-ft�x 65-ft. V1leatherL6ck0 G(High Tear).is permitted,to be used with mechanically fastened asphalt shingles,.metal roofing,slate shingles,wood shingles and wood.shakes as prescribed in the,FBC. Exposure on the roof deck shall be limited to a maximum 30 days. • _ ai a , OCR14.002.6a F077i iib Page 2 of 4 This evaluation report is provided for State of'Flotida product approval under Rule'61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout theAuration for which this report is valid. This evaluation report does not express nor imply warranty.,installation,recommended u specifically-addressed herein. se,or other product attributes,that.are not OWENS CORNING ROOFING AND ASPHALT LLC CR EE K WeatherLock®Self-Sealing Ice&Water Barriers TECHNICAL SERVICES,LLC PRODUCT APPLICATION Min.Roof Slope:, 2:12 or in accordance in with the FBC Application: All underlayments shall be installed in accordance with.the FBC. Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners imthe deck shall be checked for protrusion and corrected prior to undertayment application. Prior to beginning installation, the underlayment'shaft be. unrolled•and allowed-to.relax-for a minimum of 3-5 minute&.. The underlayment shall be installed with.the release:backer removed and pressed fimtly into place:to,ensure complete:contact with'the deck.The undedayment shall be installed with the roll'length parallel to the eave, starting at the eave; and with minimum 3." side, laps and minimum 6"end laps staggered min.6 ft;from preceding course. Additionally,,if applying WeatherLock®Specialty Tile &.Metal, end laps shall be.primed'with ASTM D 41 primer or sealed with asphalt roof cementa rninimum.of 3-4 inches across the width of the lap. It is permissible to back nail the underlayment 12-inches on-center as needed(nails shall be installed perpendicular to deck.With the nail heads flush to the.top surface of the undedayment); Additionally,WeatherLock®Specialty Tile &'Metal shall be back-nailed when installed on roof slopes greater than 3:.12., Min.Application 40°F;Contact the manufacturer,when installing at temperatures below the minimum Temperature: application temperature. WIND RESISTANCE- The Maximum Design Pressures shown_below.were.calculated using a 2:1 margin of safety per FBC Section.1504.9. Undedayment System No 1—Weathe 6ckSoecialtyTile&Metal Only Roof Deck:. Min.15132 inch.CDX plywood;attached-to woodsupportsspaced a maximum 24"o..c: Underlayment: WeatherLock® .Specialty Tile & 'Metal: shall be applied in accordance. with manufacturer's installation;instructions•to,-the fastened deck and.backnailed along the selvage With minimum 1.2ga., 1-1/4 inch galvanized .ring shank roofing nails through: optionally`primed, 32ga. x 1-5/84nch 6 664 caps,spaced,12- ox. The applied' underlayment shall. be rolled with a minimum �516,sted roller immediately following application. .Maximum Design ;105 psf Pressure: I i OCR14002.6a FL9777-R9 Page 3 of.4 This evaluation report is provided for State-of Florida product approval under Rule 61G20.3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes orquality assurance changes throughout the duration for which this report is valid. This evaluation'report does:not express not imply warranty,installation:recommended use,or other product attributes that are not specifically addressed.herein. OWENS CORNING ROOFING AND ASPHALT LLC C R E�E.K WeatherLock(D"Self-Sealing Ice.B Water Barriers TECHNICAL SERVICES, LLC GENERAL LIMITATIONS i 1) This evaluation report is not use in the HVHZ. 2) Fire Classification is.not within thescope of this evaluation. 3.) Installation of the,evaluated product shall.comply with this report,the FBC,and the manufacturer's published application,'instructions, Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail.. 4) The roof deck shall be constructed of closely fitted plywood sheathing,46r new or existing construction. 5) The space under the deck area shall be properly.ventilated in accordance with the'FBC requirements. 6) All side lap seams-shall be installed to shed water from the deck. 7), The undeHayment;may,be used"as described in other current FBC product approval documents. 8) Design wind load pressures shall be determined for components and cladding in accordance with FBC 1609, 9) The,roof:deck shall!be designed by others in accordance with FBC requirements to resist the.design wind" load pressures for components and cladding. 10) Maximum 'Design Pressures for a given .undedayment shall meet or exceed the design wind loads determined"for the roof assembly. 1.1) All products,listed`in this report shall.be,manufactured under a quality assurance pr."ogram in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with'the Florida,Building Code 5th Edition(2014)as:evidenced in the referenced documents submitted by.the named.manufacturer. ��`��u % Pp�I R: -��� , GE ►s�'�s 2017.04.12 -Z No 74021 - *: = 15:15:46 O STATE 'OF 1y� —04'01 C O R 1 .7.N 4' _, . . Zachary R. Priest,P.E.. Florida Registration No. 0,NAC'E� `�� Organization No ANE9641 21 CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest Many company manufacturing or distributing products under-this evaluation. ; CREEKTechrilcal Services,LLC is.not owned,operated,orcontrol►ed byany company,manufacturing"or distributing products under this evaluation: ` Zachary R.Priest,"P.E.does not`have,nor will:acquire, a financial interest in any company manufacturing;or distributing products under.this evaluation. Zachary R.Priest,P.E.does not have;nor will acquire,a financial interest.in any other-entity involved in the approval process of the, product. I END OF REPORT i I OCR14002.6a FL9777-R9 Page 4 of 4 This evaluation report is provided for State of Florida product'approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which thisreport.is.valid. This evaluation report does not express nor imply warranty,installation,recommended use;or other-product attributes that are not specifically addressed herein. I � I f i