HomeMy WebLinkAboutEnergy Code`FORM'R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 17 Block 2 Waterstone 2508 AGR
Builder Name: ADAMS HOMES
Street: 8209 Amalfi Circle
Permit Office:
FEB ®
City, State, Zip: ' Fort Pierce , FL , 34951
Permit Number:
5 202�
Owner:
Jurisdiction: 661000
ST, Lucie County, Permitting
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate Zone 2 9
1. New construction or existing New (From Plans)
10. Wall Type>r1920.0 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1648.00 ft2
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent
R=13.0 272.00 ft2
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types (2603.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 2523.00 ft2
6. Conditioned floor area above grade (ft2) 2523
b. Knee Wall (Vented)
R=19.0 80.00 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(260.4 sqft.) Description Area
12. Ducts
R ft2
a. U-Factor: Dbl, U=0.33 117.49 ft2
a. Sup: Attic, Ret: Main, AH: Main
6 503.2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 70.92 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
42.0 SEER:15.00
c. U-Factor: Dbl, U=0.55 51.11 ft2
SHGC: SHGC=0.70
Area Weighted Average Overhang Depth: 6.950 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.323
a. Electric Heat Pump
42.0 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons
9. Floor Types (2523.0 sqft.) Insulation Area
Slab
EF: 0.940
a. -On -Grade Edge Insulation R=0.0 2523.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
Pstat
Glass/Floor Area: 0.103 Total Proposed Modified Loads: 67.23
PASS
Total Baseline Loads: 68.44
I hereby certify that the plans s ications covered
Revi of the plans and
D fiiE Sx
this calculation are in compl' n h the Flori ergy
specifications covered by this
Code.
calculation indicates compliancew',,��''�c���•�i
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
DATE: 01-07- 021 Winn Keomany
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.,
with the Florida ergy Code.wig
OWNER/AGEN
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
1 Compliance requires an Air Barrier and Insulation Inspection
Checklist in accordance with R402.4.1.1
and this project requires an
envelope leakage test report. with envelope leakage no greater
than 7.00 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage
to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater
than 0.050 Qn for whole house.
1/7/2021 2:35 PM EnergyGauge® USA 7.0.00 - FlaRe's202O FBC 7th Edition (2020) Compliant Software Page 1 of 5
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Lot 17 Block 2 Waterstone 25 Bedrooms: 4
Address Type:
Street Address
Building Type:
User
Conditioned Area: 2523
Lot #
17
Owner Name:
Total Stories: 1
Block/Subdivision:
Waterstone
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
ADAMS HOMES
Rotate Angle: 0
Street:
8209 Amalfi Circle
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
661000
Whole House Fan: No
City, State, Zip:
Fort Pierce ,
Family Type:
Detached
FL, 34951
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V
Design Location TMY Site
97.5 % 2.5 %
Winter Summer
Degree Days
Moisture Range
FL, ST LUCIE_CO_INTL FL_VERO_BEACH_MUNI
39 90
70 75
299
58 Medium
BLOCKS
Number Name Area Volume
1
Block1 2523 20184
SPACES
Number Name Area Volume Kitchen Occupants
Bedrooms InfilID Finished
Cooled Heated
1
Main 2523 20184
Yes 5
4 1
Yes
Yes Yes
FLOORS
# Floor Type Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 208.9 ft 0
2523 ft2 ---- 0.44
0 0.56
ROOF
/
Roof
Gable Roof
Rad Solar
SA Emitt
Emitt Deck Pitch
V
# Type Materials Area
Area Color
Barr Absor. Tested
Tested Insul. (deg)
1 Gable or Shed Composition shingles 2821 ft2
630 ft2 Medium
N 0.85
N 0.85
No 0 26.57
ATTIC
/
V
# Type Ventilation
Vent Ratio (1 in)
Area RBS
IRCC
1 Full attic Vented
300 2523 ft2 N
N
CEILING
# Ceiling Type Space
R-Value Ins Type Area
Framing Frac
Truss Type
1 Under Attic (Vented) Main
30 Blown
2523 ft2
0.11
Wood
2 Knee Wall (Vented) Main
19 Batt
80 ft2
0.11
Wood
1/7/2021 2:35 PM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software
Page 2 of 5
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
WALLS
FOrnt
Adjacent
Space
Cavity Width
_
Height
Pa
Sheathing Framing
_
Solar Below
o
1
E
Exterior
Concrete Block - Int Insul
Main
4.1 25
0
8 0
200.0 ft2
0
0
0.6
0
2
N
Exterior
Concrete Block - Int Insul
Main
4.1 57
0
8 0
456.0 ft2
0
0
0.6
0
3
W
Exterior
Concrete Block - Int Insul
Main
4.1 50
3
8 0
402.0 ft2
0
0
0.6
0
4
SE
Exterior
Concrete Block - Int Insul
Main
4.1 5
0
8 0
40.0 ft2
0
0
0.6
0
5
S
Exterior
Concrete Block - Int Insul
Main
4.1 38
3
8 0
306.0 ft2
0
0
0.6
0
6
-
Garage
Frame - Wood
Main
13 34
0
8 0
272.0 ft2
0
0.23
0.01
0
7
S
Exterior
Concrete Block - Int Insul
Main
4.1 18
9
8 0
150.0 ft2
0
0
0.6
0
8
E
Exterior
Concrete Block - Int Insul
Main
4.1 6
6
8 0
52.0 ft2
0
0
0.6
0
9
W
Exterior
Concrete Block - Int Insul
Main
4.1 5
3
8 0
42.0 ft2
0
0
0.6
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
E
Insulated
Main
None
.25
3
6 8
20 ft2
2
-
Wood
Main
None
.25
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V
#
Ornt ID
Frame Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
N
2
Vinyl Low-E Double
Yes
0.55 0.7
N
17.8 ft2
25 ft 0 in
0 ft 10 in
Drapes/blinds
None
2
N
2
Vinyl Low-E Double
Yes
0.33 0.23
N
32.4 ft2
1 ft 4 in
0 ft 10 in
None
Exterior 5
3
E
1
Vinyl Low-E Double
Yes
0.33 0.31
N
7.5 ft2
6 ft 0 in
0 ft 6 in
None
None
4
E
1
Vinyl Low-E Double
Yes
0.33 0.31
N
13.3 ft2
6 ft 0 in
2 ft 10 in
None
None
5
E
1
Vinyl Low-E Double
Yes
0.33 0.21
N
32.4 ft2
1 ft 4 in
1 ft 0 in
None
Exterior 5
6
E
1
Vinyl Low-E Double
Yes
0.33 0.21
N
38.5 ft2
1 ft 4 in
1 ft 0 in
None
Exterior 5
7
S
5
Vinyl Low-E Double
Yes
0.55 0.7
N
15.6 ft2
25 ft 0 in
0 ft 10 in
None
None
8
S
5
Vinyl Low-E Double
Yes
0.33 0.23
N
9.8 ft2
1 ft 4 in
0 ft 10 in
None
Exterior 5
9
S
5
Vinyl Low-E Double
Yes
0.33 0.23
N
16.2 ft2
1 ft 4 in
0 ft 10 in
None
Exterior 5
10
SE
4
Vinyl Low-E Double
Yes
0.33 0.23
N
12.5 ft2
7 ft 2 in
0 ft 4 in
None
Exterior 5
11
W
3
Vinyl Low-E Double
Yes
0.55 0.7
N
17.8 ft2
9 ft 10 in
0 ft 10 in
None
None
12
W
3
Vinyl Low-E Double
Yes
0.33 0.23
N
16.7 ft2
7 ft 2 in
0 ft 4 in
None
Exterior 5
13
W
3
Vinyl Low-E Double
Yes
0.33 0.23
N
30.0 ft2
9 ft 10 in
0 ft 4 in
None
Exterior 5
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
620 ft2 620 ft2
64 ft
8 ft
1
1/7/2021 2:35 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
F
INFILTRATION
Scope
Method
SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse
Proposed ACH(50)
.000356
2354.8 129.19 242.54 .1263
7
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1
Electric Heat Pump/
Split
Singl HSPF:8.5 42 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1
Central Unit/
Split
Singl SEER: 15 42 kBtu/hr cfm
0.75 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt
Conservation
1
Electric None
Garage
0.94 40 gal 62.3 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert #
Company Name
System Model # Collector Model # Area
Volume
FEF
None
None
ft2
DUCTS
/
---- Supply ----
---- Return ---
Air
CFM 25
CFM25
HVAC #
1/
# Location R-Value Area
Location Area
Leakage Type
Handler
TOT
OUT
QN RLF
Heat Cool
1 Attic 6 503.2 ft
Main 125.8 ft
Proposed Qn
Main
--- cfm
126.2 cfm
0.05 0.60
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling
Heating
Jan
Jan
Feb Mar
f X� Feb Mar
Apr
f Apr
Ma
f May
Jul
JunJul
Jun rl
rl
AuSep
ri Aug
Se
ri
Oct
Oct
Nov
Nov
HX
Dec
Dec
H
Venting
Jan
[ ] Feb X Mar
(X] A r
[ Ma
Jun
Jul
Aug
Se
[X] Oct
Nov
Dec
1/7/2021 2:35 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule: HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/sq.ft.
0 ft2
0 ft
0.3
Main
1/7/2021 2:35 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5
FORM P405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
8209 Amalfi Circle, Fort Pierce, FL, 34951
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1648.00 ft2
3. Number of units, if multiple family
1
b. Frame - Wood, Adjacent
R=13.0
272.00 ft2
c. N/A
R=
ft2
4. Number of Bedrooms
4
d. N/A
R=
ft2
5. Is this a worst case?
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
2523.00 ft2
6. Conditioned floor area (ft2)
2523
b. Knee Wall (Vented)
R=19.0
80.00 ft2
7. Windows- Description
Area
c. N/A
R=
ft2
a. U-Factor: Dbl, U=0.33
117.49 ft2
12. Ducts, location & insulation level
R ft2
SHGC: SHGC=0.23
a. Sup: Attic, Ret: Main, AH: Main
6 503.2
b. U-Factor: Dbl, U=0.33
70.92 ft2
SHGC: SHGC=0.21
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: Dbl, U=0.55
51.11 ft2
a. Central Unit
42.0 SEER:15.00
SHGC: SHGC=0.70
d. U-Factor: other (see details)
20.83 ft2
SHGC: other (see details)
14. Heating systems
kBtu/hr
Efficiency
Area Weighted Average Overhang Depth:
6.950 ft.
a. Electric Heat Pump
42.0
HSPF:8.50
Area Weighted Average SHGC:
0.323
8. Skylights Description
Area
15. Hot water systems
a. U-Factor(AVG): N/A
ft2
a. Electric
Cap:
40 gallons
SHGC(AVG): N/A
EF:0.94
9. Floor Types
Insulation
Area
b. Conservation features
a. Slab -On -Grade Edge Insulation
R=0.0
2523.00 ft2
None
b. N/A
R=
ft2
Credits (Performance method)
Pstat
c. N/A
R=
ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: J Date:
Address of New Home:
City/FL Zip:
w
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building. Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
1/7/2021 2:35 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1