Loading...
HomeMy WebLinkAboutEnergy Codei FORM R405-2017 _ FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 20 Block 54-8 IndianRiverEstates 2117 AGL Builder Name: ADAMS HOMES Street: 5608 Seagrape Drive Permit Office: City, State, Zip: Fort Pierce , FL, 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1664.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1436.00 ft2 b. Frame - Wood, Adjacent R=13.0 228.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (2115.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 2115.00 ft2 6. Conditioned floor area above grade (ft2) 2115 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(244.1 sqft.) Description Area a. Sup: Attic, Ret: Main, AH: Main 6 423 a. U-Factor: Dbl, U=0.33 159.41 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 48.56 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 35.0 SEER:16.00 c. U-Factor: Dbl, U=0.33 18.33 ft2 SHGC: SHGC=0.31 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 17.78 ft2 a. Electric Heat Pump 34.6 HSPF:8.50 SHGC: other (see details) Area Weighted Average Overhang Depth: 4.907 ft. Area Weighted Average SHGC: 0.266 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (2115.0 sgft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 2115.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Total Proposed Modified Loads: 64.32 Glass/Floor Area: 0.115 PASS Total Baseline Loads: 65.60 I hereby certify that the plans an p c' ' ations covered by of the plans and this calculation are in complia he Florida E specifications covered by this Code. calculation indicates compliance y� �ri,��''=�,�.��';,•�� with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: - 08-97-2020 Winn Keomany this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes.. with the Florida C-r�s ode OWNER/AGc"�_ BUILDING OFFICIAL: DATE: DATE: Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in'accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an Fanvelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 8/27/2020 9:15 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot 20 Block 54-8 IndianRiver Bedrooms: 4 User Conditioned Area: 2115 Total Stories: 1 1 Worst Case: No ADAMS HOMES Rotate Angle: 0 Cross Ventilation: No 661000 Whole House Fan: No Single-family New (From Plans) Address Type: Street Address Lot # 20 Block/Subdivision: IndianRiverEst PlatBook: Street: 5608 Seagrape Drive County: St. Lucie City, State, Zip: Fort Pierce , FL, 34951 CLIMATE V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 2115 17343 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2115 17343 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 179.5 ft 0 2115 ft2 ---- 0.34 0 0.66 ROOF V # Type Roof Gable Roof Materials Area Area Color Rad Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2365 ft2 530 ft2 Medium N 0.85 N 0.85 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2115 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 2115 ft2 0.11 Wood 8/27/2020 9:15 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent TO Wall Type1 Space Cavity Width Height Sheathing Framing Solar Below N Exterior Concrete Block - Int Insul Main 4.1 41 0 8 0 328.0 ft2 0 0 0.6 0 _ 2 W Exterior Concrete Block - Int Insul Main 4.1 35 0 8 0 280.0 ft2 0 0 0.6 0 3 S Exterior Concrete Block - Int Insul Main 4.1 48 6 8 0 388.0 ft2 0 0 0.6 0 4 E Exterior Concrete Block - Int Insul Main 4.1 55 0 8 0 440.0 ft2 0 0 0.6 0 5 - Garage Frame - Wood Main 13 28 6 8 0 228.0 ft2 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Wood' Main None .25 3 6 8 20 ft2 2 - Wood Main None .25 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Double Yes 0.33 0.23 N 6.9 ft2 1 ft 0 in 0 ft 10 in None None 2 W 2 Vinyl Low-E Double Yes 0.33 0.31 N 5.0 ft2 8 ft 0 in 0 ft 10 in None None 3 W 2 Vinyl Low-E Double Yes 0.33 0.21 N 32.4 ft2 1 ft 0 in 0 ft 10 in None None 4 W 2 Vinyl Low-E Double Yes 0.33 0.21 N 16.2 ft2 1 ft 0 in 5 ft 0 in None None 5 W 2 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ft2 8 ft 0 in 3 ft 0 in None None 6 S 3 Vinyl Low-E Double Yes 0.33 0.23 N 6.9 ft2 1 ft 0 in 0 ft 10 in None None 7 S 3 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 1 ft 0 in 0 ft 10 in None None 8 E 4 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 11 ft 0 in 1 ft 2 in None None 9 E 4 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 0 in 0 ft 10 in None None 10 E 4 Vinyl Low-E Double Yes 0.33 0.23 N 64.8 ft2 11 ft 0 in 0 ft 10 in None None 11 N 1 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 432 ft2 432 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000365 2023.3 111.08 208.9 .1276 7 8/27/2020 9:15 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Sing[ HSPF:8.5 34.6 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 35 kBtu/hr 1167 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 DUCTS ---- Supply ---- \/ # Location R-Value Area ---- Return --- Location Area Leakage Type Air Handler CFM 25 TOT CFM25 OUT QN RLF HVAC # Heat Cool 1 Attic 6 423 ft' Main 105.75 Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Coolin Jan HFeb Mar Heating Jan Feb lMar�-Apr Ventin Jan Feb X Mar Ceiling Fans: Julrj ArMayJun Jul Ma rjJun ri Apr [ May Jun Jul Au AuSep Aug Se ri Se [X] Oct Oct Oct Nov XNov X Nov Dec Dec Dec Thermostat Schedule: HERS 2006 Reference Schedule Type 1 2 3 Hours 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 PM 80 Cooling (WEH) AM 78 PM 78 Heating (WD) AM 66 PM 68 Heating (WEH) AM 66 PM 68 78 78 80 78 78 78 78 78 66 66 68 68 66 66 68 68 78 78 78 78 78 78 78 78 78 78 78 78 66 66 68 68 68 68 66 66 68 68 68 68 78 78 78 78 68 68 68 68 78 78 78 78 68 68 68 68 80 78 78 78 68 68 68 68 80 78 78 78 68 68 68 68 80 78 78 78 68 66 68 66 80 78 78 78 68 66 68 66 MASS Mass Type Area Thickness Furniture Fraction Space 116- Default 8 Ibs/s .ft. 0 ftz 0 ft 0.3 Main 8/27/2020 9:15 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD .4 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Main 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 35.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2115 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.346 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.266 14. Heating system: Capacity 34.6 c) Area 7c. 244.1 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.94 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 13.0 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. :i_5�� Builder Signat Date: Address of New Home: 5608 Seagrape Drive City/FL Zip: Fort Pierce, FL 34951 8/27/2020 9:15:10 AM EnergyGaugeO USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1