HomeMy WebLinkAboutEnergy Codei
FORM R405-2017
_ FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 20 Block 54-8 IndianRiverEstates 2117 AGL
Builder Name: ADAMS HOMES
Street: 5608 Seagrape Drive
Permit Office:
City, State, Zip: Fort Pierce , FL, 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1664.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1436.00 ft2
b. Frame - Wood, Adjacent
R=13.0 228.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (2115.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 2115.00 ft2
6. Conditioned floor area above grade (ft2) 2115
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(244.1 sqft.) Description Area
a. Sup: Attic, Ret: Main, AH: Main
6 423
a. U-Factor: Dbl, U=0.33 159.41 ft2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 48.56 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
35.0 SEER:16.00
c. U-Factor: Dbl, U=0.33 18.33 ft2
SHGC: SHGC=0.31
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: other (see details) 17.78 ft2
a. Electric Heat Pump
34.6 HSPF:8.50
SHGC: other (see details)
Area Weighted Average Overhang Depth: 4.907 ft.
Area Weighted Average SHGC: 0.266
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (2115.0 sgft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 2115.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Total Proposed Modified Loads: 64.32
Glass/Floor Area: 0.115
PASS
Total Baseline Loads: 65.60
I hereby certify that the plans an p c' ' ations covered by
of the plans and
this calculation are in complia he Florida E
specifications covered by this
Code.
calculation indicates compliance
y� �ri,��''=�,�.��';,•��
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
DATE: - 08-97-2020 Winn Keomany
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes..
with the Florida C-r�s ode
OWNER/AGc"�_
BUILDING OFFICIAL:
DATE:
DATE:
Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in'accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
Fanvelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
8/27/2020 9:15 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 20 Block 54-8 IndianRiver Bedrooms: 4
User Conditioned Area: 2115
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Single-family
New (From Plans)
Address Type: Street Address
Lot # 20
Block/Subdivision: IndianRiverEst
PlatBook:
Street: 5608 Seagrape Drive
County: St. Lucie
City, State, Zip: Fort Pierce ,
FL, 34951
CLIMATE
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
2115 17343
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
2115 17343 Yes 5
4 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 179.5 ft 0
2115 ft2 ---- 0.34 0 0.66
ROOF
V #
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 2365 ft2 530 ft2 Medium
N 0.85 N 0.85 No 0 26.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 2115 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
2115 ft2 0.11 Wood
8/27/2020 9:15 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
TO Wall
Type1
Space
Cavity Width
Height
Sheathing Framing Solar Below
N
Exterior
Concrete
Block - Int Insul
Main
4.1 41
0
8 0
328.0 ft2
0
0 0.6
0
_ 2
W
Exterior
Concrete
Block - Int Insul
Main
4.1 35
0
8 0
280.0 ft2
0
0 0.6
0
3
S
Exterior
Concrete
Block - Int Insul
Main
4.1 48
6
8 0
388.0 ft2
0
0 0.6
0
4
E
Exterior
Concrete
Block - Int Insul
Main
4.1 55
0
8 0
440.0 ft2
0
0 0.6
0
5
-
Garage
Frame - Wood
Main
13 28
6
8 0
228.0 ft2
0
0.23 0.01
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft In
Ft In
1
W
Wood'
Main
None
.25
3
6 8
20 ft2
2
-
Wood
Main
None
.25
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Ornt ID
Frame
Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
N
1
Vinyl
Low-E Double
Yes
0.33 0.23
N
6.9 ft2
1 ft 0 in
0 ft 10 in
None
None
2
W
2
Vinyl
Low-E Double
Yes
0.33 0.31
N
5.0 ft2
8 ft 0 in
0 ft 10 in
None
None
3
W
2
Vinyl
Low-E Double
Yes
0.33 0.21
N
32.4 ft2
1 ft 0 in
0 ft 10 in
None
None
4
W
2
Vinyl
Low-E Double
Yes
0.33 0.21
N
16.2 ft2
1 ft 0 in
5 ft 0 in
None
None
5
W
2
Vinyl
Low-E Double
Yes
0.33 0.31
N
13.3 ft2
8 ft 0 in
3 ft 0 in
None
None
6
S
3
Vinyl
Low-E Double
Yes
0.33 0.23
N
6.9 ft2
1 ft 0 in
0 ft 10 in
None
None
7
S
3
Vinyl
Low-E Double
Yes
0.33 0.23
N
16.2 ft2
1 ft 0 in
0 ft 10 in
None
None
8
E
4
Vinyl
Low-E Double
Yes
0.55 0.7
N
17.8 ft2
11 ft 0 in
1 ft 2 in
None
None
9
E
4
Vinyl
Low-E Double
Yes
0.33 0.23
N
48.6 ft2
1 ft 0 in
0 ft 10 in
None
None
10
E
4
Vinyl
Low-E Double
Yes
0.33 0.23
N
64.8 ft2
11 ft 0 in
0 ft 10 in
None
None
11
N
1
Vinyl
Low-E Double
Yes
0.33 0.23
N
16.2 ft2
1 ft 0 in
0 ft 10 in
Drapes/blinds
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
432 ft2
432 ft2
64 ft
8 ft
1
INFILTRATION
#
Scope
Method
SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse
Proposed ACH(50) .000365
2023.3 111.08
208.9
.1276
7
8/27/2020 9:15 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/
Split
Sing[ HSPF:8.5
34.6 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Singl SEER: 16
35 kBtu/hr
1167 cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric None
Garage
0.94 40 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
DUCTS
---- Supply ----
\/ # Location R-Value Area
---- Return ---
Location Area Leakage Type
Air
Handler
CFM 25
TOT
CFM25
OUT
QN
RLF
HVAC #
Heat Cool
1 Attic 6 423 ft'
Main
105.75 Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Coolin Jan HFeb Mar
Heating Jan Feb lMar�-Apr
Ventin Jan Feb X Mar
Ceiling Fans:
Julrj
ArMayJun Jul
Ma rjJun ri
Apr [ May Jun Jul
Au
AuSep
Aug
Se
ri Se
[X]
Oct
Oct
Oct
Nov
XNov
X Nov
Dec
Dec
Dec
Thermostat Schedule: HERS 2006 Reference
Schedule Type 1
2 3
Hours
4 5 6 7
8
9
10
11
12
Cooling (WD) AM 78
PM 80
Cooling (WEH) AM 78
PM 78
Heating (WD) AM 66
PM 68
Heating (WEH) AM 66
PM 68
78 78
80 78
78 78
78 78
66 66
68 68
66 66
68 68
78 78 78
78 78 78
78 78 78
78 78 78
66 66 68
68 68 68
66 66 68
68 68 68
78
78
78
78
68
68
68
68
78
78
78
78
68
68
68
68
80
78
78
78
68
68
68
68
80
78
78
78
68
68
68
68
80
78
78
78
68
66
68
66
80
78
78
78
68
66
68
66
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
116- Default 8 Ibs/s .ft.
0 ftz
0 ft
0.3
Main
8/27/2020 9:15 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4
2017 EPL DISPLAY CARD
.4
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Main
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
4
13. Cooling system: Capacity
35.0
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
2115
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.346
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.266
14. Heating system: Capacity
34.6
c) Area
7c.
244.1
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.94
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
13.0
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level a) Ceiling fans
a) Under attic 11 a. 30.0 b) Cross ventilation No
b) Single assembly 11 b. c) Whole house fan No
c) Knee walls/skylight walls 11 c. d) Multizone cooling credit
d) Radiant barrier installed 11 d. No e) Multizone heating credit
f) Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
:i_5��
Builder Signat Date:
Address of New Home: 5608 Seagrape Drive City/FL Zip: Fort Pierce, FL 34951
8/27/2020 9:15:10 AM EnergyGaugeO USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1