HomeMy WebLinkAboutEnergy CodeFORWR405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 19 Block 1 Waterstone 1780 BGR
Builder Name: ADAMS HOMES
i Street: 5376 Lugo Street
Permit Office:
City, State, Zip: Fort Pierce , FL , 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate
Zone 2 ).
1. New construction or existing New (From Plans)
10. Wall Type�1513.4 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1245.40 ft2
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent
R=13.0 268.00 ft2
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types (1897.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1780.00 ft2
6. Conditioned floor area above grade (ft2) 1780
b. Knee Wall (Vented)
R=19.0 117.00 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(177.0 sqft.) Description Area
12. Ducts
R ft2
a. U-Factor: Dbl, U=0.33 113.31 ft2
a. Sup: Attic, Ret: Main, AH: Main
6 356
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 45.94 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
28.4 SEER:15.00
c. U-Factor: Dbl, U=0.55 17.78 ft2
SHGC: SHGC=0.70
Area Weighted Average Overhang Depth: 2.639 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.272
a. Electric Heat Pump
28.2 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons
9. Floor Types (1780.0 sqft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 1780.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
Pstat
Glass/Floor Area: 0.099 Total Proposed Modified Loads: 52.16
PASS
Total Baseline Loads: 52.74
I hereby certify that the plans s cations covered b
e . of the plans and
0� STA?A
this calculation are in compl' the Florid gy
Code.
specifications covered by this
"��s+
calculation indicates compliance
y�`,,,°s , €',•�
�O
with the Florida Energy Code.
,
r�n,Y�•, .,;. ,.° `'�ti,
PREPARED BY:
Before construction is completed
�
DATE: 01-13-2021 Winn Kenmany
this building will be inspected for
�
O ,
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florid C
WE
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
-.Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.060 Qn for whole house.
1/13/2021 8:40 AM 7.0.00 - IFlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Lot 19 Block 1 Waterstone 17 Bedrooms: 3
Address Type:
Lot Information
Building Type:
User
Conditioned Area: 1780
Lot #
19
Owner Name:
Total Stories: 1
Block/Subdivision:
Waterstone
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
ADAMS HOMES
Rotate Angle: 0
Street:
5376 Lugo Street
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
661000
Whole House Fan: No
City, State, Zip:
Fort Pierce ,
Family Type:
Detached
FL, 34951
New/Existing:
New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp
Heating
Design Daily Temp
V
Design Location TMY Site
97.5 % 2.5 %
Winter Summer
Degree Days
Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI
39 90
70 75
299
58 Medium
BLOCKS
Number Name Area Volume
1
Blockl 1780 15664
SPACES
Number Name Area Volume Kitchen Occupants
Bedrooms InfilID Finished
Cooled Heated
1
Main 1780 15664
Yes 4
3 1
Yes
Yes Yes
FLOORS
# Floor Type Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 155.7 ft 0
1780 ft2 ---- 0.38
0 0.62
ROOF
/
Roof
Gable Roof
Rad Solar
SA Emitt
Emitt Deck Pitch
# Type Materials Area
Area Color
Barr Absor. Tested
Tested Insul. (deg)
1 Gable or Shed Composition shingles 1990 ft2
446 ft2 Medium
N 0.85
N 0.85
No 0 26.57
ATTIC
/
V
# Type Ventilation
Vent Ratio (1 in)
Area RBS
IRCC
1 Full attic Vented
300 1780
ft2 N
N
CEILING
# Ceiling Type Space
R-Value Ins Type Area
Framing Frac
Truss Type
1 Knee Wall (Vented) Main
19 Batt
117 ft2
0.11
Wood
2 Under Attic (Vented) Main
30 Blown
1780 ft2
0.11
Wood
1/13/2021 8:40 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 4
FORM R405-2020 INPUT SUMMARY CI-IFIC:KI IRT RFPnRT
WALLS
Adjacent
ornt To Wall Type
Space
Cavity Width
_#
Height
Sheathing Framing Solar Below
_ o
1 W Exterior Concrete Block - Int Insul
Main
4.1 40 0 8
0
320.0 ft2
0
0 0.6
0
2 N Exterior Concrete Block - Int Insul
Main
4.1 40 6 8
0
324.0 ft2
0
0 0.6
0
3 NE Exterior Concrete Block -'Int Insul
Main
4.1 3 0 9
6
28.5 ft2
0
0 0.6
0
4 E Exterior Concrete Block - Int Insul
Main
4.1 11 10 9
"6
112.4 ft2
0
0 0.6
0
5 SE Exterior Concrete Block - Int Insul
Main
4.1 3 0 9
6
28.5 ft2
0
0 0.6
0
6 S Exterior Concrete Block - Int Insul
Main
4.1 54 0 8
0
432.0 ft2
0
0 0.6
0
7 - Garage Frame - Wood
Main
13 33 6 8
0
268.0 ft2
0
0.23 0.01
0
DOORS
# Ornt Door Type Space
Storms
U-Value.
Width
Height
Area
Ft
In
Ft In
1 E Insulated
Main
None
.25
3
6 8
20 ft2
2 - Wood
Main
None
.25
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/ Wall
Overhang
V # Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1 W 1 Metal Low-E Double
Yes
0.55 0.7 N
17.8 ft2
14 ft 4 in
0 ft 10 in
None
None
2 W 1 Vinyl Low-E Double
Yes
0.33 0.23 N
32.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
3 N 2 Vinyl Low-E Double
Yes
0.33 0.23 N
32.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
4 NE 3 Vinyl Low-E Double
Yes
0.33 0.21 N
11.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
5 E 4 Vinyl Low-E Double
Yes
0.33 0.21 N
23.2 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
6 SE 5 Vinyl Low-E Double
Yes
0.33 0.21 N
11.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
7 S 6 Vinyl Low-E Double
Yes
0.33 0.23 N
48.6 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
GARAGE
# Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 591 ft2 591 ft2
64 ft
8 ft
1
INFILTRATION
# Scope Method SLA
CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000391
1827.5 100.26 188.23
.1312
7
HEATING SYSTEM
# System Type Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/ Split
Singl HSPF:8.5 .
28.2 kBtu/hr
1
sys#1
1/13/2021 8:40 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORM R405-2020 INPl1T SUMMARY rWI=r1<1 PQT QGanOT
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Singl SEER: 15 28.4 kBtu/hr cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.94 40 gal
62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft2
DUCTS
/ ---- Supply ----
---- Return ----
Air
CFM 25
CFM25
HVAC #
V/ # Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1 Attic
6 356 ft2
Main
89 ft2 Proposed Qn
Main
--- cfm
106.8 cfm 0.06
0.60
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling Jan Feb
Heating f X Jan f X Feb
Mar
Mar
�Ap r
Ar f
Jul
May Jun Jul
Ma rj Jun rl
Au
Auil
ri
Se
SeP
Oct
Oct
Nov
Nov
Dec
XDec
Ventin [ Jan [ Feb
X Mar
Apr [
May JunJul
Aug
Se
[X]
Oct
Nov
[ Dec
Thermostat Schedule: HERS 2006
Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8
9
10
11
12
Cooling (WD) AM
78
78 78
78 78 78
78
78
80
80
80
80
PM
80
80 78
78 78 78
78
78
78
78
78
78
Cooling (WEH) AM
78
78 78
78 78 78
78
78
78
78
78
78
PM
78
78 78
78 78 78
78
78
78
78
78
78
Heating (WD) AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
Heating (WEH) AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s .ft.
0 ft2
0 ft
0.3
Main
1/13/2021 8:40 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the 'EnergyPerformance Index, the more efficient the home.
5376 Lugo. Street, Fort Pierce, FL, 34951
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1245.40 ft2
b. Frame - Wood, Adjacent
R=13.0
268.00 ft2
3. Number of units, if multiple family
1
c. N/A
R=
ft2
4. Number of Bedrooms
3
d. N/A
R=
ft2
5. Is this a worst case?
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
1780.00 ft2
6. Conditioned floor area (ft2)
1780
b. Knee Wall (Vented)
R=19.0
117.00 ft2
7. Windows- Description
Area
c. N/A
R=
ft2
a. U-Factor: Dbl, U=0.33
113.31 ft2
12. Ducts, location & insulation level
R ft2
SHGC: SHGC=0.23
a. Sup: Attic, Ret: Main, AH: Main
6 356
b. U-Factor: Dbl, U=0.33
45.94 ft2
SHGC: SHGC=0.21
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: Dbl, U=0.55
17.78 ft2
a. Central Unit
28.4 SEER:15.00
SHGC: SHGC=0.70
d. U-Factor: N/A
ft2
SHGC:
14. Heating systems
kBtu/hr
Efficiency
Area Weighted Average Overhang Depth:
2.639 ft.
a. Electric Heat Pump
28.2
HSPF:8.50
Area Weighted Average SHGC:
0.272
8. Skylights Description
Area
15. Hot water systems
a. U-Factor(AVG): N/A
ft2EF:0.94
a. Electric
Cap:
40 gallons
SHGC(AVG): N/A
b. Conservation features
9. Floor Types
Insulation
Area
None
a. Slab -On -Grade Edge Insulation
R=0.0
1780.00 ft2
Credits (Performance method)
Pstat
b. N/A
R=
ft2
c. N/A
R=
ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise; a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date:
Address of New Home: City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a'Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
1/13/2021 8:40 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1