HomeMy WebLinkAbout0025 Bergeron Window permit revision form OFFICE USE ONLY:
DATE FILED: _____________________________ PERMIT # _______________________________
REVISION FEE: ___________________________ RECEIPT # ______________________________
______________________________________________________________________________________________
PLANNING & DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982-5652
(772) 462-1553
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
LOCATION/SITE
ADDRESS:
___________________________________________________________________________________
___________________________________________________________________________________
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
___________________________________________________________________________________
___________________________________________________________________________________
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: ______________________ ST. LUCIE CO CERT. #: ____________
BUSINESS NAME: _________________________________________________________________
QUALIFIERS NAME: ________________________________________________________________
ADDRESS: _______________________________________________________________________
CITY: _______________________ STATE: _______________ ZIP: _______________________
PHONE (DAYTIME): ________________________ FAX: _____________________________
OWNER/BUILDER INFORMATION:
NAME: ____________________________________________________________________________
ADDRESS:__________________________________________________________________________
CITY: _____________________________ STATE: __________ ZIP: __________________
PHONE (DAYTIME: ___________________________ FAX: _____________________________
ARCHITECT/ENGINEER INFORMATION:
NAME: ____________________________________________________________________________
ADDRESS: _________________________________________________________________________
CITY: _____________________________ STATE: ____________ ZIP: ___________________
PHONE (DAYTIME): ___________________________ FAX: ____________________________
SLCCC: 9/23/09
Revised 06/30/17
CERTIFICATION NO: NI010606-R3
DATE: 05/09/2011
CERTIFICATION PROGRAM: Structural
COMPANY: Eastern
CODE: 1783-1
REVISION DATE: 02/11/2020
To verify that the “Notice of Product Certification” is valid, please visit www.NAMICertification.com to assure that the
product is active and currently listed. This certification represents product conformity to the applicable specification and
that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim
certification status. Please review and advise NAMI if any corrections are required to this document.
COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION
Eastern Architectural Systems Series “1531/2551"
10030 Bavaria Road Vinyl Double Hung Window
Ft. Myers, FL 33913 w/Nailing Fin
Configuration: X/X
Glazing: Insulating Glass (Annealed)
Frame: W-1210mm(47.5") H-1820mm(71.5")
Sash: W-1130mm(44.38") H-900mm(35.63")
SPECIFICATION PRODUCT RATING
AAMA/WDMA/CSA 101/I.S.2/A440-05 H-R50 1210 x 1820 (48 x 72)
Product Tested By: Architectural Testing, Inc.
Report No: 71347.05-501-47
Expiration Date:February 28, 2024
Administrator’s Signature:
NATIONAL ACCREDITATION AND
MANAGEMENT INSTITUTE, INC.
4794 George Washington Memorial Highway
Hayes, VA 23072
Tel: (804) 684-5124
Fax: (804) 684-5122
NOTICE OF PRODUCT CERTIFICATION
CERTIFICATION NO: NI010628-R2
DATE: 05/13/2011
CERTIFICATION PROGRAM: Structural
COMPANY: Eastern
CODE: 1783-1
REVISION DATE: 02/11/2020
To verify that the “Notice of Product Certification” is valid, please visit www.NAMICertification.com to assure that the
product is active and currently listed. This certification represents product conformity to the applicable specification and
that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim
certification status. Please review and advise NAMI if any corrections are required to this document.
COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION
Eastern Architectural Systems Series “2551" Impact Rated
10030 Bavaria Road Vinyl Double Hung Window
Ft. Myers, FL 33913 w/Nailing Fin
Configuration: X/X
Glazing: IG-1/8" Annealed Glass/
Laminate-1/8" Annealed Glass/0.090" PVB by Solutia/
1/8" Annealed Glass
Frame: W-1219mm(48") H-1829mm(72")
Sash: W-1130mm(44.5") H-914mm(36")
SPECIFICATION PRODUCT RATING
ASTM E1886-02/E1996-02 Design Pressure: +50/-50 psf
Wind Zone 4-Missile Level D
Product Tested By: Certified Testing Laboratories.
Report No: CTLA-2062W-6
Expiration Date:June 30, 2024
Administrator’s Signature:
NATIONAL ACCREDITATION AND
MANAGEMENT INSTITUTE, INC.
4794 George Washington Memorial Highway
Hayes, VA 23072
Tel: (804) 684-5124
Fax: (804) 684-5122
NOTICE OF PRODUCT CERTIFICATION
L. Roberto Lomas P.E. Engineering Evaluation Report
1432 Woodford Rd.
Lewisville, NC 27023 Report No.: 510955A
434-688-0609
rllomas@lrlomaspe.com
1 of 1 Luis R. Lomas, P.E.
FL No.: 62514
10/19/2020
Manufacturer: Eastern Architectural Systems
16341 Domestic Ave.
FT Myers, FL 33912
Product Line: Series 2551 Vinyl Fin Frame Double Hung Window - LMI
Compliance:
The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of
Business and Professional Regulation for Statewide Acceptance per Rule 61G20-3.005 method 1(a). The product listed
herein complies with requirements of the Florida Building Code.
Supporting Technical Documentation:
1. Approval document: drawing number 08-00566 Revision B, prepared, signed and sealed by Luis Roberto
Lomas P.E.
2. Test Report No.: CTLA 2062W-6 signed and sealed by Ramesh Patel, P.E.
Certified Testing Laboratories, Orlando, FL.
ASTM E1886/ E1996 Large Missile Impact Test, Level D, Wind Zone 4
Cyclic Load Test, ±50.0 psf design pressure
3. Test Report No.: ATI 71347.05-501-47 signed by Michael L. Mackereth.
Architectural Testing, York, PA.
AAMA/WDMA/CSA 101/I.S.2/A440
Design pressure: ±50.0psf
Water penetration resistance 7.5psf
4. Anchor calculations, report number 510955A, prepared, signed and sealed by Luis Roberto Lomas P.E.
Limitations and Conditions of use:
Maximum design pressure: ±50.0psf
Maximum unit size: 48" x 72”
Units must be glazed per ASTM E1300 Refer to approval documents for details.
This product is not rated to be used in the HVHZ.
This product is impact resistant and does not require impact protection in wind borne debris regions.
Frame material to be rigid PVC.
Installation:
Units must be installed in accordance with approval document, 08-00566 Revision B.
Certification of Independence:
Please note that I don’t have nor will acquire a financial interest in any company manufacturing or distributing the
product(s) for which this report is being issued. Also, I don’t have nor will acquire a financial interest in any other entity
involved in the approval process of the listed product(s).
72"
MAX
FRAME
HEIGHT
6" MAX
6" MAX
6" MAX
24"
MAX
O.C.
.
.
.
DESIGN PRESSURE RATING
+50.OPSF
NOTES:
1. MAXIMUM SASH SIZE: 44 3/8" x 35 3/8
2. MAXIMIUM D.L.0.: 41 3/4" X 32 1/4"
1
.
48" MAX FRAME WIDTH
16"
MAX O.C.
0
.
2551 DOUBLE HUNG WINDOW
X
.
.
.
.
EXTERIOR VIEW
IMPACT RATING
LARGE AND SMALL
MISSILE IMPACT
2
6" MAX
SHEET NO.
TABLE OF CONTENTS
ELEVATION AND NOTES
INSTALLATION DETAILS
DESCRIPTION
REV
B
A
DESCRIPTION
REVISIONS
MANUFACTURER'S NAME CHANGE
REVISED INSTALLATION DETAILS
DATE
03/03/09
06/18/15
R.L.
R.L.
APPROVED
NOTES:
1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH
REQUIREMENTS OF THE FLORIDA BUILDINIG CODE.
2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY
TRANISFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE
RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD.
3. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS
PROVIDED.
4. SHIM AS NEEDED WITH LOAD BEARING SHIMS. SHIM WHERE SPACE OF 1/16" OR GREATER
OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4".
5. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE
OF SUSTAINING APPLICABLE LOADS.
6. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS.
7. FRAME MATERIAL: EXTRUDED RIGID PVC.
8. UNITS MUST BE GLAZED PER ASTM El 300-04, SEE SHEET 3 FOR GLASS OPTIONS.
9. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN Wll\ID
BORNE DEBRIS REGIONS.
10. FOR ANCHORNG INTO WOOD FRAMINIG OR 2X BUCK USE #8 WOOD SCREWS WITH
SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE
ANCHORS AS SHOWN INI ELEVATIONS AND INSTALLATION DETAILS.
11. ALL FASTENERS TO BE CORROSION RESISTANT.
12. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR
MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN
SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW:
A. WOOD - MINIMUM SPECIFIC GRAVITY OF G=O.42
13.GEOMETRIC SHAPES ARE ALSO APPROVED. APPROVED GEOMETRIC SHAPES DIMENSIONS
SHALL NOT EXCEED INSCRIBED DIMENSIONS OF APPROVED RECTANGULAR ASSEMBLY SHOWN
IN SHEET 2. GEOMETRIC SHAPES ARE NOT LIMITED TO SHAPES SHOWN HEREIN.
--0.3 Eastern
9 ALUMINUM AND VINYL
DRAWN:
A.M.
SCALE NTS
EASTERN ARCHITECTURAL SYSTEMS
A DIVISION OF
EASTERN METAL SYPPLY
16341 DOMESTIC AVE
FORT MYERS, FL 33912
800-432-2204
2551 DOUBLE HUNG
48" X 72"
ELEVATION AND NOTES
DWG NO.
DATE 06/06/12
08-00566
SHEET 1 OF 2
REV
B
SIGNED: 06/18/2015
. 4.. SZ * 0 010.,625y , * S
A- -
*. STATE OF :85
Op.:LO R\01 :....
..
.
APPROVED
SEALANT
BEHI IND FIN
#8 WOOD
SCREW
7/16" MIN
EDGE DISTANCE
EXTERIOR
APPROVED
SEALANT
BEHIND FIN
7/16" MIN __f T
EDGE DISTANCE
#8 WOOD
SCREW
1/-
1 1/4" MIN.
EMBEDMENT
INTERIOR
1 1/4" MIN.
EMBEDMENT
VERTICAL CROSS SECTION
WOOD FRAMING OR 2X BUCK INSTALLATION
WOOD
FRAMING
BY OTHERS
1/4" MAX.
E SHIM SPACE
1/4" MAX
E SHIMI SPACE
WOOD
FRAMING
BY OTHERS
WOOD FRAMING
BY OTHERS
#8 WOOD
SCREW
1 1/4"
MINI.
EMBEDMENT
APPROVED --
SEALANT
BEHI IND FIN
7/16" MIN _
EDGE DISTANCE
1/4" MAX
SHIM SPACE
INTERIOR
REV
0 0
-EXTERIOR
JAMB INSTALLATION DETAIL
WOOD FRAMING OR 2X BUCK INSTALLATION
NOTES:
1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS,
NOT SHOWN FOR CLARITY.
2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE
DESIGNED IN ACCORDANCE WITH ASTM E2112
A
DESCRIPTION
REVISIONS
MANUFACTURER'S NAME CHANGE
REVISED INSTALLATION DETAILS
--0.3 Eastern
ria V' ALUMINUM AND VINYL
#N 3 OVVS AND 0 C.3 0 - S
DRAWN:
A.M.
SCALE NTS
B
1/8" ANN - --
1
DATE
03/03/09
06/18/15
R.L.
R.L.
1/8" ANN
090" PVB BY EASTIVIAN
1/8" ANN
GLAZING DETAILS
EASTERN ARCHITECTURAL SYSTEMS
A DIVISION OF
EASTERN METAL SYPPLY
16341 DOMESTIC AVE
FORT MYERS, FL 33912
800-432-2204
2551 DOUBLE HUNG
48" X 72"
INSTALLATION DETAILS
DWG NO.
DATE 06/06/12
08-00566
SHEET 2 OF 2
REV
B
APPROVED
SIGNED: 06/18/2015
f<2·so E N *6%
S *•10«625 . *2
A- -
*. STATE OF :85
.%>.:?OR\Ot:2'ff....-L**RO/WAIDWf?E.Fl(/41 8·fl I tj\*8 4
CERTIFICATION NO: NI011134-R1
DATE: 06/08/2012
CERTIFICATION PROGRAM: Structural
COMPANY: Eastern
CODE: 1783-1
REVISION DATE: 02/09/2016
To verify that the “Notice of Product Certification” is valid, please visit www.NAMICertification.com to assure that the
product is active and currently listed. This certification represents product conformity to the applicable specification and
that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim
certification status. Please review and advise NAMI if any corrections are required to this document.
COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION
Eastern Architectural Systems Series “623" Vinyl Fin Frame
16341 Domestic Avenue Impact Sliding Glass Door
Fort Myers, FL 33912
Configuration: OXO
Glazing: IG-1/8" Tempered Glass/Laminate-1/8"
Annealed Glass/0.090" Interlayer (Eastman PVB)/1/8"
Annealed Glass or 5/32" Tempered Glass/Laminate-
5/32" Annealed Glass/0.090" Interlayer (Eastman
PVB)/ 5/32" Annealed Glass
Frame: W-3658mm(144") H-2438mm(96")
Panel: W-1232mm(48.5") H-2369mm(93.25")
DLO: W-1029mm(40.5") H-2165mm(85.25")
SPECIFICATION PRODUCT RATING
AAMA/WDMA/CSA 101/I.S.2/A440-05
ASTM E1886-05/E1996-05
SD-C50 3658 x 2438 (144 x 96)
Design Pressure: +50/-50 psf
Wind Zone 4-Missile Level D
Qualifies Configurations: O/X/OX/XO/OXO
Product Tested By: Certified Testing Laboratories
Report No: CTLA 2050W/CTLA 2050W-1/ESP009160P-1/ESP009160P-2
Expiration Date:May 31, 2021
Administrator’s Signature:
NATIONAL ACCREDITATION AND
MANAGEMENT INSTITUTE, INC.
4794 George Washington Memorial Highway
Hayes, VA 23072
Tel: (804) 684-5124
Fax: (804) 684-5122
NOTICE OF PRODUCT CERTIFICATION
L. Roberto Lomas P.E. Engineering Evaluation Report
1432 Woodford Rd.
Lewisville, NC 27023 Report No.: 512351B
434-688-0609
rllomas@lrlomaspe.com
1 of 1 Luis R. Lomas, P.E.
FL No.: 62514
10/22/2020
Manufacturer: Eastern Architectural Systems
16341 Domestic Ave.
FT Myers, FL 33912
Product Line: Series 623 Vinyl Sliding Glass Door, OXO 144” X 96” Impact
Compliance:
The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of
Business and Professional Regulation for Statewide Acceptance per Rule 61G20-3.005 method 1(a). The product listed
herein complies with requirements of the current Florida Building Code.
Supporting Technical Documentation:
1. Approval document: drawing number 08-01671 Revision B, prepared, signed and sealed by Luis Roberto Lomas
P.E.
2. Report No.: ESP009160P-2 signed and sealed by Ramesh Patel P.E.
Element Materials Technology, Wausau, WI
AAMA/WDMA/CSA 101/I.S.2/A440
Design pressure: ±50.0psf
Water penetration resistance 7.5psf
3. Report No.: ESP009160P-1 signed and sealed by Ramesh Patel P.E.
Element Materials Technology, Wausau, WI
ASTM E1886/ E1996 Large Missile Impact, Level D, Wind Zone 4
Cyclic Load Test, ±50.0psf design pressure
4. Anchor calculations, report number 512351-1A, prepared, signed and sealed by Luis Roberto Lomas P.E.
Limitations and Conditions of use:
Maximum design pressure: ±50.0psf
Maximum unit size: 144” x 96”
Units must be glazed per ASTM E 1300 according to glazing details in approval drawing.
This product is not rated to be used in the HVHZ.
This product is impact resistant and does not require impact protection in wind borne debris regions.
Frame material to be rigid PVC.
Installation:
Units must be installed in accordance with manufacturer’s installation instructions and approval document 08 -01671
Revision B.
Certification of Independence:
Please note that I don’t have nor will acquire a financial interest in any company manufacturing or distributing the
product(s) for which this report is being issued. Also, I don’t have nor will acquire a financial interest in any other entit y
involved in the approval process of the listed product(s).