Loading...
HomeMy WebLinkAboutREG SPECS - 3-15-21Bulletin LP-T P122h- Type R122H First -Stage Regulator Introduction The Type R122H is an Underwriters Laboratories listed regulator designed for Tao -Stage LP -Gas systems. The unit is designed to reduce the tank pressure to an outlet pressure of 10 psig. The compact size makes it ideal for small domestic applications and underground tanks. The outlet pressure setting is nonadjustable and is factory set at a nominal 10 psig. Screened drip - lip vents are oriented over the outlet as standard. Features 20 Year Recommended Replacement Life - The R122H is designed using rugged time proven design concepts and constructed of corrosion resistant materials, both intemally and externally. With proper installation and periodic inspection and maintenance the R122H regulator will meet a 20 Year Recommended Replacement Life. Dual Gauge Taps - Built-in 118 inch NPT gauge taps orificed to a number 54 drill size on both the inlet and outlet side of the regulator allow for easy testing. • Durability - A fluorocarbon valve disc is utilized to improve lockup performance in systems with contaminated gas. • Improved Regulation - A large fabric -reinforced diaphragm and stabilizer clip deliver accurate and stable regulation. • Easy Installation - The units compact size and easily accessible inlet and outlet wrench flats make installation easy even in the tightest installations. FISHER Figure 1. Type R 122H FM-Stoge Regulator Superior Overpressure Protection - The combination of a high capacity relief valve and large vent provide overpressure protection that exceeds UL standards. When used in conjunrtion with a R622 or R652, the two -stage system will limit the downstream pressure from the second -stage to 2 psig even in a double failure situation. Corrosion -Resistant - Added corrosion resistance from an internal and external coating process for all castings prior to painting, stainless steel relief valve spring and retainer and a corrosion resistant relief valve seat. Positive Draining Spring Case - When installed properly with the spring case vent pointed down. the design allows moisture formed in the spring case to drain out limiting the problems with corrosion and freezing water in the spring case. 4r EMERSON. Process Management Bulletin LP-7: R122H Table 1. Ordering Information TYRE NUMBER CAPACITY BTUIHR PROPANEni CONNECTIONS INLET x OUTLET NOMINAL OUTLET SETTING R122H-AAJ 1.100.0130 Ito-rfltlt x 12-Mch NPT 10 psrg (0.69 bar) 1 C2aacav s based on 30 PSIG Q07 butt atie! Oresum wd 2D% moop 1xie w �E�l 0. OR Figure 2. Type R 122H Dimensions Or—RES (MMI LP -Gas Equlprnent Emerson Process Management Regulator Technologies. Inc. USA - Headquarters MdOamM Texas 75WS-1872 USA Telephone: 1 (800) 558-SM Telephone: 1 (972) 6483574 For lzdw Wfotrttadon visit www.f henegulators.comfip The Emersw iopo Is a trademark errs WOW menu of Emerson Eleebte Co An Ww ma fcs we fire pmperh of tl w Waspeca►e owns m Raker 8 a M2* ownea ar Fww Corrbafs. We— a bufeMss of EMlerson Praoess Mitt The aOfREYL, of fob prrbl cow are preserfted Oor bVomlaamo purposes ". and white every ailed had beee made to en$= mar amnily. mar M not b be oonabsred = WUMOM or pSrteSww express ar, s m . mp nnv Ore pNdtar servtass aesamed tlerest ar taw use ar appbcab=j We rest 9 foe r4M to t OOV a mtpratre the desWa ar spedftafts arsuch OMOM a1 aatr me", M it ao(lce. Emerson process Managersr0r, does not aSSM MSpar4*xwy far the saleclt 9 use cratweanzwe of aotr product. RaspwaM tr fm pt :per salorm . use and mamtarse "Of snir EMwjw procw A mmpes ad product ra a 13 solely wMh me purchaser EMERSON.. WsonROOM &UaOW"dit .MwT=WWW rs ft.. 2M. 2010. AN tf,RWerved Process Management Bulletin 71 .1:R622 Type R622 Pressure Reducing Reguiator • Comp • Protei Scree • Hinh Canacity • Inlet and Outlet Pressure Gauge Taps Figure 1 t ..: .. ?Iessme Reducng Regldu(C' Relief teight Introduction Type R622 direct -operated. spring -loaded regulators applications. These regulators can be used with provide economical pressure reducing control in natural. manufactured. or propane gases and have the a variety of residential. commercial. and industrial same inlet and outlet pressure capabilities. FISHER EMERSON. Bulletin 71.1: R622 Specifications Body Size and End Connection Style0) Pressure Registration 112 NPT inlet and outlet Internal Maximum Allowable Inlet PressureM Operating: 125 psig (8,6 bar) Emergency: 125 psig (8,6 bar) Except 1.8 to 2.24nches w.c. (4 to 5 mbar) spring range which has operating and emergency pressures of 60 psig (4,1 bar) Maximum Allowable Outlet (Casing) Pressure() Operating to Avoid Internal Part Damage: 3 psid (0.21 bar d) above outlet pressure setting Emergency: 20 psi (1.4 bar) Outlet Pressure Ranges See Table 1 Orifice Size 118-inch (3.2 mm) orifice Flow Coefficients Wide -Open C. for Relief Sizing: 12.5 Wide -Open C. for Relief Sizing: 0.36 Cl: 35 IEC Sizing Coefficients XT 0.78 Fl): 0.82 FL: 0.89 Flow Capacities See Table 2 Relief Performance See Figure 4 Internal Relief Performance Start -to -Discharge is 8 to 22-inches w.c. (20 to 55 mbar) for setpoints from 1.8 to 20-inches w.c. (4 to 50 mbar) Start -to -Discharge is 140 to 200% over setpoint from 20-inches w.c. to 2.2 psig (50 to 152 mbar) Spring Case Vent Connections 314 NPT with removable screen Temperature Capabilities( ) -200 to 160°F (-290 to 71 °C) Approximate Weight 2.35 pounds (1 kg) Construction Materials Body, Spring Case, Diaphragm Plate, and Orifice: Aluminum Diaphragm, Disk, and O-ring: Nitrite (NBR) Adjusting Screw and Pushpost: Delrin® Closing Cap: ASA Thermoplastic (UV -Ray Resistant) Control Spring: Zinc -plated steel Machine Screw, Spring Seat, and Lever: Zinc -plated steel Valve Stem: Zinc Relief Valve Spring, Relief Spring Retainer, Lever Pin, and Vent Screen: Stainless steel 1 Tile — — trtaas � fhb eusiersn a any soptca�bie ro m,�m+ snoWd nat ae exceaaed. 0 us a nsnk an�00 bye I. Cu pon da r� and Co. In addition, Type R622 regulators have internal relief across the diaphragm to help minimize overpressure. Any outlet pressure above the start -to -discharge point of the non-adjustable relief valve spring moves the diaphragm off of the relief valve seat, allowing excess pressure to bleed out through the screened spring case vent. rebte 1. Outlet Pressure Ranges Specifications The Specifications section lists specifications, for Type R622 Pressure Reducing Regulators. As it originally comes from the factory, specifications for a given regulator are stamped on the spring case nameplate. OUTLET PRESSURE RANGE CONTROL SPRING PART NUM13ER CONTROL SPRING COLOR CODE SPRING WIRE DIAMETER. INCHES (MM) SPRING FREE LENGTH. INCHES (11t1r1) 18 to 2.24xhes w.c. (4 to S mbar) T 14453MO 12 Purple 0.051 (1.30) 3.40 (86.4) 5 to 7-Mcim w.t (12 to 17 nMar) T 14398TOO 12 oraw 0.062 (1.56) 3.40 (86.4) 6.5 to "d1es w c. (16 to 22 mar) T 14399TOO12 yam 0.067 (1.70) 3.61(91.7) 910134ndues W.C. (22 to 32 RUM) T 14400T0012 sum 0.072 (1.83) 4.10 (104) 13 to 204ndees w.c. (32 to 50 Mar) T 14401TOD 12 Gray 0.080 (2.03) 3.60 (91.4) 16 to 35-in m w.c. (40 to 87 mar) T 14402TOO 12 Punk 0 093 (2.36) 3.52 (89.4) 1 to 2.2 RS19 (69 to 152 mbar) T 14403TOO12 LkPt Blue 0105(2.67) 3.66 (93.0)