Loading...
HomeMy WebLinkAboutTANK SPECS - 3-15-21Quality Steel Corporation AG/UG Propane Tanks :&HT 1450 wg. AND UP oaaRnWMATF ARMEGROUND/UNDEGROUND (AG/UG) VESSEL DIMENSIONS AND SPECIFICATIONS WATER CAPACITY DIAMETER (OD) HEAD TYPE OVERALL LENGTH OVERALL HEIGHT LEG* WIDTH LEG** SPACING WEIGHT (Ibs.) **QUANTITY FULL LOAD PER STACK *120 wg. 24" Ellip. 5'-8" 3' 1'-11/2" 2'-101/2" or 3'-11" 260 108 1 96 16 1 12 *250 wg. 30" Hemi. 7'-10" 3'-8" 1'-5" 4'-2V 480 54 9 *320 wg. 30" Hemi. 9'-7" 3'-8" 1'-5" 5' 620 45 9 500 wg. 371/2" Hemi. 10' 4'-2" 1'-8" 5' 950 37130 8 1 6 1000 wg. 41" Hemi. 16, 4'-5" V-8" 10'-10 1,800 171 15 615 1450 wg. 461/2" Ellip. 17'-4" 4'-11" 1'-9" 11'-7° 2,650 12 4 1990 wg. 461/2" Ellip. 23'-11" 4'-11" 1'-9" 16' 3,520 8 4 Oimenskans and spedflcwftu shown are approximate. Individual vessels may vary. • Leg spacing ♦/- 20. Leg widths and spacing may vary► based on mfg. location. Check with your salesperson for details. 120, 250, 320 Me& standard tanks - no holes In legs (one center hole on reques4 5= and 1000 wg. standard tanks - 2 holes 16" on renter. 1430 wg. and up as shown above. •• Full load and stick quantities vary by shipping location. Check with your salesperson for details. General Specifications - Conforms to the latest edition of ASME Rules for Construction of Pressure Vessels, Section VIII, Division 1. Complies with NFPA 58. - Rated at 250 psig from -20' F to 1250 F. All vessels registered with National Board. - Two service options available: Option 1: Ready -to -bury underground option, coated with either powder coated phenolic epoxy finish or liquid applied epoxy primer coat followed by urethane top coat, supplied with composite AG/UG dome. Option 2: Aboveground option, coated with either powder coated TGIC polyester finish or liquid applied epoxy primer coat followed by urethane top coat, supplied with steel AG/UG dome. - All vessels are shipped vacuum pre -purged to enable simplified first fill of the vessel. Updated June 30, 2015 #A • ^M MOAN 17. jp�.1111 PROPANE CONSTRUCTION NOTES 1. All pipe and fittings above ground and inside buildingshall be SCH..40 Galvanized. ASTM A120 or . AGA approved.corrugated stainless steel •(C.S.S.T.) pipe'. , 2• All. polypipe and fittings shall be ASTM D251-3 or ASTI�I D2517 and shag be buded-outside underground at a depth of 18" with Warningtape and p . p (racer wire. 3. All pipe and meter locaffons are approximate and subject to - change.. .4. Ali polypipe shall be Joined by heat fusion or approved mechanical . couplings. • 5. All'galvanized pipe shall be threaded. 5: Alt pipe shall be pressure tested to 20 PSI fof a period of 24 hours. - • UNDERGROUND TANK INSTALLAif ok . 2" to G• • DOWNGRADED AWAY • FROM DOME • ml / • 40 Y Zf� t •i. • I• • _ 1 / 1 ANODE CABLE • ' • ••. • . SACRIFICIAL ANODE • ;,f•�. • . i �• .•1 ' (MAGNESIUM >3AGi . ' • .. ' _ REGQi ATOR . SHUT GAS OFF AT • 'r GU tDE VA16YE .x •IR A@O t G ADE_�►J� ' R 1 • • • HARK PIG TAPE ter' V • RISE • GRADE/CONCRETE SLEEVE : p• p . • •r•• • • •Y•d • • • • •i= d e• p 1• - 0 ! • r 1jp10 f••0• r • V ��� • I4f b a ••; .� I ••• • • • A • �J • . • • • �• ••t•` V Q O • • L O • ..� . O • oUtMORovRo %?-OAS CORMINLn SERVICE LINE °D TRACE NIitE w